Next Article in Journal
Guide to the Effects of Vibration on Health—Quantitative or Qualitative Occupational Health and Safety Prevention Guidance? A Scoping Review
Next Article in Special Issue
Time–Frequency Analysis of Railway Bridges Forced and Free Vibrations Identified by Wavelet Transform
Previous Article in Journal
Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts
Previous Article in Special Issue
Feasibility Analysis of Monitoring Contact Wire Rupture in High-Speed Catenary Systems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effectiveness of Dynamic Vibration Absorber on Ground-Borne Vibration Induced by Metro

School of Railway Engineering, Iran University of Science and Technology, Tehran 16846-13114, Iran
*
Author to whom correspondence should be addressed.
Vibration 2025, 8(4), 62; https://doi.org/10.3390/vibration8040062
Submission received: 8 August 2025 / Revised: 27 September 2025 / Accepted: 2 October 2025 / Published: 5 October 2025
(This article belongs to the Special Issue Railway Dynamics and Ground-Borne Vibrations)

Abstract

The application of dynamic vibration absorbers (DVAs) is a countermeasure to suppress vibrations induced by railway traffic. A key advantage of the DVA application is that it does not require any changes to the path of vibration propagation or the receiver of vibration. A review of the literature reveals the necessity of deriving the optimum properties of DVA to mitigate railway vibrations. To this end, the optimum DVA properties were investigated through the development of a two-dimensional finite element model of the track-tunnel-soil system. The model was validated using the results of a field test. A parametric study was made to obtain the optimum properties of DVA for different soils surrounding the tunnel. The results of the model analysis indicate that the DVA has better vibration reduction for metro tunnels built in soft soils as compared to those surrounded by medium and stiff soils. Also, the results disclose that the DVA reduces vibration radiated on the ground surface when the DVA natural frequency is tuned to a low frequency. Using the results of the parametric study, graphs are suggested to select the optimum properties of the DVA as a function of the soil around the tunnel.
Keywords: ground-borne vibrations; metro; railway; finite element analysis; DVA ground-borne vibrations; metro; railway; finite element analysis; DVA

Share and Cite

MDPI and ACS Style

Sadeghi, J.; Toloukian, A.; Mehravar, S. Effectiveness of Dynamic Vibration Absorber on Ground-Borne Vibration Induced by Metro. Vibration 2025, 8, 62. https://doi.org/10.3390/vibration8040062

AMA Style

Sadeghi J, Toloukian A, Mehravar S. Effectiveness of Dynamic Vibration Absorber on Ground-Borne Vibration Induced by Metro. Vibration. 2025; 8(4):62. https://doi.org/10.3390/vibration8040062

Chicago/Turabian Style

Sadeghi, Javad, Alireza Toloukian, and Sogand Mehravar. 2025. "Effectiveness of Dynamic Vibration Absorber on Ground-Borne Vibration Induced by Metro" Vibration 8, no. 4: 62. https://doi.org/10.3390/vibration8040062

APA Style

Sadeghi, J., Toloukian, A., & Mehravar, S. (2025). Effectiveness of Dynamic Vibration Absorber on Ground-Borne Vibration Induced by Metro. Vibration, 8(4), 62. https://doi.org/10.3390/vibration8040062

Article Metrics

Back to TopTop