Article

Measurements of Wake Concentration from a Finite Release of a Dense Fluid Upstream of a Cubic Obstacle

Glenn Department of Civil Engineering, Clemson University, Clemson, SC 29634, USA
*
Author to whom correspondence should be addressed.
Fluids 2025, 10(8), 194; https://doi.org/10.3390/fluids10080194
Submission received: 26 June 2025 / Revised: 26 July 2025 / Accepted: 26 July 2025 / Published: 29 July 2025
(This article belongs to the Special Issue 10th Anniversary of Fluids—Recent Advances in Fluid Mechanics)

Abstract

Results are reported for a series of small-scale experiments that examine the dispersion of dense gas released upstream of an isolated building. The experiments replicate the geometry of the Thorney Island Phase II field tests and show good qualitative agreement with the flow regimes observed therein. The experiments were run in a water flume, and the flow is characterized by the Richardson number (Ri), where high Ri represent relatively high density releases. For low Ri the dense cloud flows over and around the building and any fluid drawn into the building wake is rapidly flushed. However, for high Ri, the dense cloud collapses, flows around the building, and is drawn into the wake. The dense fluid layer becomes trapped in the wake and is flushed by small parcels of fluid being peeled off the top of the layer and driven up and out of the wake. Results are presented for the concentration field along the center plane (parallel to the flow) of the building wake and time series of concentration just above the floor and downstream of the building. The time series for low-Ri and high-Ri flows are starkly different, with differences explained in terms of the observed flow regimes.
Keywords: dense gas; building wake; dispersion; Richardson number; experimental dense gas; building wake; dispersion; Richardson number; experimental

Share and Cite

MDPI and ACS Style

Akhter, R.; Kaye, N. Measurements of Wake Concentration from a Finite Release of a Dense Fluid Upstream of a Cubic Obstacle. Fluids 2025, 10, 194. https://doi.org/10.3390/fluids10080194

AMA Style

Akhter R, Kaye N. Measurements of Wake Concentration from a Finite Release of a Dense Fluid Upstream of a Cubic Obstacle. Fluids. 2025; 10(8):194. https://doi.org/10.3390/fluids10080194

Chicago/Turabian Style

Akhter, Romana, and Nigel Kaye. 2025. "Measurements of Wake Concentration from a Finite Release of a Dense Fluid Upstream of a Cubic Obstacle" Fluids 10, no. 8: 194. https://doi.org/10.3390/fluids10080194

APA Style

Akhter, R., & Kaye, N. (2025). Measurements of Wake Concentration from a Finite Release of a Dense Fluid Upstream of a Cubic Obstacle. Fluids, 10(8), 194. https://doi.org/10.3390/fluids10080194

Article Metrics

Back to TopTop