Next Article in Journal
A Comparative Study on the Efficiency and Sustainability of Rice Bran Oil Extraction Methods
Previous Article in Journal
Advances in Optical Sensing Technologies for On-Site Detection of Harmful Residues in Food: Principles and Recent Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Exfoliated Graphite as a Solid Sorbent in Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction for Determination of Chromium and Vanadium in Herbs

by
Małgorzata Osińska
,
Piotr Krawczyk
and
Magdalena Krawczyk-Coda
*
Faculty of Chemical Technology, Poznan University of Technology, Berdychowo 4, 60-965 Poznań, Poland
*
Author to whom correspondence should be addressed.
Foods 2025, 14(23), 4075; https://doi.org/10.3390/foods14234075
Submission received: 31 October 2025 / Revised: 22 November 2025 / Accepted: 26 November 2025 / Published: 27 November 2025
(This article belongs to the Section Food Analytical Methods)

Abstract

In this research, a preconcentration procedure was developed for the sequential determination of chromium and vanadium using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS). Due to low concentrations, chromium and vanadium were determined following preconcentration onto exfoliated graphite using ultrasound-assisted dispersive micro-solid-phase extraction (US DMSPE). The experimental parameters, including pH of the sample solution, the amount of exfoliated graphite, extraction time, elution conditions, as well as the main parameters of HR-CS GFAAS, were investigated. The calculated limits of detection for Cr and V were 0.003 µg g−1 and 0.006 µg g−1, respectively. The preconcentration factors obtained for Cr and V were 28 and 34, respectively. The RSD ranged from 0.3% to 3.4% for Cr and from 0.9% to 4.6% for V. The accuracy of this method was validated by analyses of INCT-MP4-2 (Mixed Polish Herbs) certified reference material. The measured chromium and vanadium contents were in satisfactory agreement with the certified values according to the t-test for a 95% confidence level. The proposed method was successfully applied for the determination of both elements in herbs such as hawthorn flower, hawthorn fruit, motherwort, white mulberry leaf, common milkweed, mistletoe, valerian root, and horse chestnut bark.
Keywords: high-resolution continuum source GFAAS; ultrasound-assisted dispersive micro solid-phase extraction; exfoliated graphite; chromium; vanadium; herbs high-resolution continuum source GFAAS; ultrasound-assisted dispersive micro solid-phase extraction; exfoliated graphite; chromium; vanadium; herbs

Share and Cite

MDPI and ACS Style

Osińska, M.; Krawczyk, P.; Krawczyk-Coda, M. Exfoliated Graphite as a Solid Sorbent in Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction for Determination of Chromium and Vanadium in Herbs. Foods 2025, 14, 4075. https://doi.org/10.3390/foods14234075

AMA Style

Osińska M, Krawczyk P, Krawczyk-Coda M. Exfoliated Graphite as a Solid Sorbent in Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction for Determination of Chromium and Vanadium in Herbs. Foods. 2025; 14(23):4075. https://doi.org/10.3390/foods14234075

Chicago/Turabian Style

Osińska, Małgorzata, Piotr Krawczyk, and Magdalena Krawczyk-Coda. 2025. "Exfoliated Graphite as a Solid Sorbent in Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction for Determination of Chromium and Vanadium in Herbs" Foods 14, no. 23: 4075. https://doi.org/10.3390/foods14234075

APA Style

Osińska, M., Krawczyk, P., & Krawczyk-Coda, M. (2025). Exfoliated Graphite as a Solid Sorbent in Ultrasound-Assisted Dispersive Micro-Solid-Phase Extraction for Determination of Chromium and Vanadium in Herbs. Foods, 14(23), 4075. https://doi.org/10.3390/foods14234075

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop