1. Introduction
One of the challenges in characterizing the thermo-mechanical transformation process under fatigue loading is the combination of elevated temperatures with fairly low strain amplitudes. This combination of a low volume fraction with the difficulty of measuring magnetic properties at elevated temperatures while applying mechanical deformation to the material creates difficult conditions for experimental evaluation.
AISI 347 (X6CrNiNb18-10, 1.4550) is a metastable austenitic stainless steel often used in piping and structural components of nuclear power plants. Being metastable, it can undergo a phase transformation from paramagnetic
austenite into ferromagnetic
martensite. This transformation may happen in two ways: by cooling it down to the martensite start temperature
or by mechanical deformation [
1,
2]. The higher the temperature, the more mechanical deformation is required for
transition to occur.
In 1979, Cohen, Olson, and Clapp defined martensitic transformation within a wider class of displacive (diffusionless) transformations as “shear dominant, lattice distortive, diffusionless transformation occurring by nucleation and growth” [
3]. Experimental investigations later showed that plastic deformation of
austenite can lead to (I) direct transformation to
martensite; (II) transformation into
martensite; or (III) transition to
via a transient
phase [
4].
Direct
transformation was first described by Bain [
5]. Bain’s model shows how a simple distortion allows a face-centered cubic (fcc) lattice to be transformed into a body-centered cubic (bcc) lattice with an intermediate tetragonal distortion. Several other models have been proposed to describe the
transformation, including Kurdjumow and Sachs [
6], Nishiyama [
7], Pitsch [
8], and Bogers and Burgers [
9].
If
is considered the temperature at which martensite and austenite are in thermodynamic equilibrium, then at temperatures above
, austenite is the more energetically favorable phase, while below
,
martensite is more favorable. The transition from
to
does not happen exactly at
. It is necessary to undercool austenite to the martensite start temperature
to initiate the thermal
transition [
2]. This delay is due to the existence of non-chemical energy barriers such as interfacial and elastic energy [
10]. This means that a critical driving force is needed to initiate the martensitic transformation. This critical force corresponds to the chemical free energy difference
,
between undeformed austenite and
martensite at the
temperature, where the transformation occurs without any additional external energy. When a load is applied to the material,
increases. This means a smaller gap between
and
is needed to reach the critical amount of free energy.
It was noted by Hansel [
11] that the amount of deformation-induced martensite
as a function of strain can generally be characterized by
Figure 1. Three sections can be distinguished based on the rate of phase transformation: (I) accelerated rate; (II) constant rate; (III) decelerated rate. It was demonstrated by Smaga [
12] that the kinetics of cyclic strain also follow a similar curve. There are certain simplifications that were implemented in this work: two linear ranges were defined. LR1 corresponds to the highest rate of phase transformation, and LR2 is the rate of phase transformation near saturation, where most of the austenite has already transformed.
Estimating the remaining fatigue life based on the amount of
martensite would be relatively straightforward if the operational temperature of the component remained constant. Unfortunately, this is rarely the case. For AISI 347, the formation of
martensite is significantly reduced above 100 °C, and it is generally accepted that no phase transformation takes place at the temperatures of a pressurized water reactor of about 320 °C. However, there is experimental evidence [
13] that
transformation still occurs at these temperatures, but in extremely small quantities.
In this study, these small quantities of deformation-induced martensite have been experimentally measured, which allowed some conclusions to be drawn about phase transformation kinetics at elevated temperatures.
2. Materials and Methods
This work features several testing and measurement methods that have been developed at Saarland University and are now also being used at the University of Applied Sciences Kaiserslautern. These methods include uniaxial magnetic balance and magnetic force imaging. Ohmic heating of the fatigue specimen was realized by a step-down transformer with multiple primary taps connected to a PID controller. Fatigue testing was conducted under total strain control, with constant and step-wise increasing amplitudes.
2.1. Magnetic Methods
Two magnetic measurement methods have been used during this study: a uniaxial magnetic balance (UMB) and magnetic force imaging (MFI).
The UMB is a magnetic balance consisting of two permanent magnets mounted on one axis. The force between the magnets is measured by two load cells and calibrated to the ferrite volume fraction based on standard calibration samples, provided by Helmut Fischer GmbH, originally meant for Feritscope [
14]. Fatigue specimens were placed in such a manner that the gauge length is centered between the two magnets. This initial alignment was performed by moving the entire UMB with a micrometer screw until the force readout from both load cells became equal. The UMB system enabled in situ detection of small fractions of deformation-induced martensite during fatigue loading. The resolution of the UMB in offline measurements can exceed 0.01 Fe%, while for in situ measurements, the resolution was affected by the heating current, as well as the mechanical movement of the fatigue specimen. Further information about the UMB can be found in [
15].
MFI is a scanning technique where the force interaction between a permanent NdFeB magnetic tip and a sample is measured. The magnetic tip used in this study had a diameter of 0.3 mm, and most of the scans were performed at a working distance (WD) between 10 and 20 µm. The imaging process was realized by line scanning in XY coordinates at a constant speed of 0.4 mm/s. Scanning started with a fast trace line (6 mm/s), where no data were acquired. This step was taken to pre-magnetize the material for the retrace line, where the force response is measured, and also to avoid possible backlash in the actuators. After the retrace is complete, the Y-stage moves the sensor to the next line. As a result, data are obtained only in one direction of scanning. The typical spatial resolution of a scan is 0.05 mm. The lateral resolution is strictly limited by the magnetic tip diameter and is dependent on the working distance. In this work, it can be estimated to be between 0.3 and 0.5 mm. To be analyzed with MFI, fatigue specimens were cut with electric discharge machining (EDM) in the axial direction, embedded in resin, ground, and polished to 1 µm with a diamond suspension. Further information about MFI can be found in [
16].
2.2. Thermo-Mechanical and Elevated Temperature Fatigue Testing Rig
In order to realize in situ magnetic measurements with the UMB, it is essential to have a sufficient amount of space around the fatigue specimen. A solution was found in a system that passes alternating current up to 800 A at 50 Hz frequency through the specimen. It has been built around a commercial 20 kN Servopulser servo-hydraulic fatigue testing machine (Shimadzu Deutschland GmbH, Duisburg, Germany) as illustrated in
Figure 2 and
Figure 3.
The fatigue specimen was gripped by current injection clamps, which had been gold-plated to improve electrical contact. These clamps were then attached to the water-cooled grips of the fatigue machine. The load cell of the fatigue machine was electrically insulated from the rest of the frame to prevent current leakage. The current was supplied by a custom-made mains transformer with multiple primary windings and a single high-current secondary winding. The voltage output was regulated by a PID controller through a solid-state tap changer.
A heat shield, machined from a single copper block, was used to protect the UMB from extreme temperature changes. The heat shield geometry follows the shape of the fatigue specimen and allows unobstructed access for the UMB. To maintain a stable temperature, the grips and the heat shield were continuously water-cooled with 15 °C water.
A CellaTemp PA 10 pyrometer with a thermopile sensor from Keller HCW GmbH (Ibbenbüren, Germany) was used to monitor the fatigue specimen temperature. The pyrometer was placed at a distance of 155 mm from the pyrometer lens to the specimen surface. At this distance, the field of view of the pyrometer is 3.23 mm in diameter, which is appropriate for 6 mm diameter fatigue specimens. The measuring range of this pyrometer spans from 0 to 1000 °C, which corresponds to a wavelength of 14 to 8 µm. Temperature was measured at the center of the specimen gauge length.
An extensometer had been set up to measure the travel between the lower grip and the upper part of the fatigue specimen, as shown in
Figure 3. This configuration provided acceptable strain measurement results after calibration was performed with a standard 12 mm gauge length extensometer. This calibration was performed by comparing the amplitudes of the two extensometers in a stress-controlled test. A stress amplitude of around 100 MPa was chosen to remain in the pure elastic regime.
2.3. Material and Specimen Geometry
This study focuses on austenitic stainless steel AISI 347 (1.4550, X6CrNiNb18-10). The unique alloying element of this steel is niobium, which has a higher affinity for carbon than chromium. This prevents the formation of chromium carbides and results in improved resistance to intergranular corrosion. This steel is also considered metastable and undergoes deformation-induced phase transformation from paramagnetic austenite to ferromagnetic martensite under plastic deformation at room temperature. This change from a paramagnetic to a ferromagnetic state is what has been largely exploited in this work to analyze the phase transformation kinetics.
The raw material was manufactured by means of continuous casting to a square cross-section using an electromagnetic stirring device. It was then hot-rolled to change the cross-section from square to round with a diameter of around 31 mm. In the next step, the material went through solution annealing at a temperature of 1058 °C. Final turning to a diameter of 30 mm was performed after cooling. All these steps were performed by the manufacturer, and no additional heat treatment was applied on-site. The chemical composition, as per the manufacturer’s certificate, is specified in
Table 1. The material was then further machined to the geometry specified in
Figure 4. As a final preparation step, specimens were electrochemically polished to reduce the amount of
martensite that could have formed on the surface due to machining. Measured by the UMB, the initial ferromagnetic volume fraction
was on average 0.82% for all specimens.
4. Discussion
Electrical resistance measurement during strain increase tests was conducted to determine the lowest strain amplitude at which the austenite lattice was affected. Electrical resistance (or conductivity) measurements are widely regarded as sensitive indicators of microstructural changes [
18,
19,
20,
21,
22], as dislocation movements can occur in the early stages of fatigue and subsequently affect the mobility of valence electrons within the lattice. A strain increase test, with parameters identical to those described in
Section 3.1, was performed, and electrical resistance was measured by the four-probe method. The only difference was the introduction of a load-free hold time of 60 min after every step. The temperature measured during the hold time
is therefore named the hold temperature, and the temperature when the cyclic load was applied
—cycle temperature. Thermo-electric currents were compensated by subtracting the voltage drop without current continuously in 3-s intervals (3 s with power supply on, 3 s off).
From
Figure 13, one can observe that electrical resistance first decreases from
= 0.09% to 0.15% and only then starts to increase. This first change in electrical resistance corresponds very well to the first change in ferromagnetic volume fraction (see
Figure 5a) that was observed at
= 0.10%. It can therefore be said that the cyclic strain limit of about 0.08% is valid for the given material at ambient temperature. This cyclic strain limit can potentially serve as a quick way of estimating the fatigue endurance limit.
Measured by a UMB, the ferromagnetic volume fraction
represents an average value over the fatigue specimen gauge length, with only slightly higher surface sensitivity. However, the material itself is not entirely homogeneous, and a localized phase transformation could potentially take place. In order to check this hypothesis, MFI was used to map the spatial distribution of
martensite in fatigue specimens after the constant amplitude tests described in
Section 3.2. These results are presented in
Figure 14 and
Figure 15.
All numerical values of MFI measurements represent the ferromagnetic volume fraction (or density), except for
Figure 14a, where the amount of deformation-induced martensite exceeded the calibration table values and therefore has arbitrary units.
The most uniform distribution of martensite was observed following the isothermal test at 17 °C. At 80 °C, there was strong evidence of martensite forming in axial bands. In these bands, Fe% values reached up to 30%, while the surrounding troughs showed levels as low as 10%. At 100 °C, vertical bands were present as well, but a new trend also began to become apparent—a higher martensite volume in the transition region from the gauge to the shaft. In this transitional region, the ferrite content reading was 11%, while at the center of the gauge length, it was only 2.7%. This behavior could be linked to the increased shear deformation in these areas due to slight lateral movement of the fatigue specimen.
Compared to
Figure 14, the colormap range in
Figure 15 was reduced from 25 Fe% to 1.5 Fe%, since
transformation at these temperatures was significantly reduced. Nevertheless, an increase in the Fe% reading of about 1.8% could be observed in the fatigue specimen after the 200 °C fatigue test (
Figure 15a). Fatigue specimens tested at 240 °C and 320 °C showed a very similar quantity and distribution of
martensite. There was only a slight increase of about 0.25 Fe% at the gauge length relative to the shoulders of the fatigue specimen. This increase is likely to be only indirectly related to the fatigue load. Since the specimen surface was first ground with sandpaper and then polished with 6, 4, and 1 µm diamond suspension, it is possible that the stability of austenite was first affected by fatigue loading and then
martensite developed at the gauge length by mechanical polishing.
The influence of surface flatness on MFI measurement was also considered. Due to the mechanical polishing, the surface of the sample had a slightly rounded shape, which resulted in a 3 to 4 µm difference in working distance. After considering this, it was found that the change in working distance can only account for one-tenth of the ferromagnetic volume fraction difference between the gauge length and the shafts of the specimen in
Figure 15.
5. Conclusions
The experimental results presented in this paper demonstrate how the deformation-induced transition from austenite to martensite is affected by elevated temperatures. In situ magnetic and electrical resistance measurements during strain increase fatigue tests showed that a strain amplitude of 0.1% was already sufficient to form martensite at room temperature. At elevated temperatures, 240 °C appeared to be the transition temperature, at which less than 0.25 Fe% was measured, right until the specimen fracture at 0.22% strain amplitude.
The kinetics of transformation were further investigated in a series of isothermal constant amplitude fatigue tests. From this data, an empirical mathematical model was developed to describe the maximum rate of phase transformation. This model describes the kinetics of transformation as an exponential function of temperature, where the rate of phase transformation decreases with temperature, asymptotically approaching zero but never actually reaching it. The spatial distribution of martensite in isothermal fatigue tests played a significant role in how the volume fraction was estimated and requires further research where shear and uniaxial strains can be separated more clearly.