Simulation-Based Visual-Comfort and Energy-Optimised Lighting Design for Residential Buildings: A Comparative Study of Manual and DIALux-Based Approaches
Abstract
1. Introduction
1.1. Energy Inefficiency in Buildings
1.2. Impact of Residential Lighting on Health
1.2.1. The Circadian Rhythm
1.2.2. Impact of Artificial Lighting on Human Health
1.3. Lighting Quality Metrics and Performance Factors
2. Materials and Methods
2.1. Experimental Design
2.2. Experimental Units and Sampling Strategy
2.3. Experimental Conditions
2.3.1. Condition A: Manual Lumen-Method Design
2.3.2. Condition B: DIALux-Based Optimised Design
2.4. Calculation Procedure
- Average Illuminance (lux):
- Electrical Energy Consumption (kWh):
2.5. Statistical Analysis
3. Results
3.1. Development of Simulation Models Using DIALux
3.2. Energy Consumption Comparison
3.3. Comparison of Illuminance Levels Between Existing and Proposed Designs
3.4. Comparison of Luminous Efficacy
4. Discussion
4.1. Energy Efficiency and Performance Outcomes
4.2. Illuminance and Visual Comfort
4.3. Luminous Efficacy and Technological Integration
4.4. Comparative Insights and Practical Implications
4.5. Role of Daylight Harvesting and Future Directions
4.6. Lighting Quality Considerations
4.7. Limitations and Future Research Directions
5. Conclusions
Author Contributions
Funding
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Carbon Trust. Lighting Overview Guide; Carbon Trust: London, UK, 2017; Available online: https://www.carbontrust.com/our-work-and-impact/guides-reports-and-tools/lighting-overview-guide (accessed on 24 March 2026).
- Gupta, R.; Gregg, M. Assessing Energy Use and Overheating Risk in Net Zero Energy Dwellings in UK. Energy Build. 2018, 158, 897–905. [Google Scholar] [CrossRef]
- Building Research Establishment (BRE). BRE Briefing Note: Progress on Energy Efficiency in England and Priorities for the Warm Homes Plan; Building Research Establishment (BRE): Watford, UK, 2025. [Google Scholar]
- Department for Levelling Up, Housing and Communities (DLUHC). Chapter 2: Energy Efficiency. In English Housing Survey 2023–24: Energy Efficiency; DLUHC: London, UK, 2024. [Google Scholar]
- Citadini de Oliveira, C.; Catão Martins Vaz, I.; Ghisi, E. Retrofit Strategies to Improve Energy Efficiency in Buildings: An Integrative Review. Energy Build. 2024, 321, 114624. [Google Scholar] [CrossRef]
- Chartered Institution of Building Services Engineers (CIBSE). Lighting Guide LG9: Lighting for Communal Residential Buildings; CIBSE Publications: London, UK, 2022; ISBN 978-1-914543-32-6. [Google Scholar]
- Ticleanu, C. Impacts of Home Lighting on Human Health. Light. Res. Technol. 2021, 53, 453–475. [Google Scholar] [CrossRef]
- Jalali, M.S.; Jones, J.R.; Tural, E.; Gibbons, R.B. Human-Centric Lighting Design: A Framework for Supporting Healthy Circadian Rhythm Grounded in Established Knowledge in Interior Spaces. Buildings 2024, 14, 1125. [Google Scholar] [CrossRef]
- Office for National Statistics (ONS). Age of the Property Is the Biggest Single Factor in Energy Efficiency of Homes. Available online: https://www.ons.gov.uk/peoplepopulationandcommunity/housing/articles/ageofthepropertyisthebiggestsinglefactorinenergyefficiencyofhomes/2021-11-01 (accessed on 24 March 2026).
- Boyce, P. Light, Lighting and Human Health. Light. Res. Technol. 2022, 54, 101–144. [Google Scholar] [CrossRef]
- Della Valle, N.; Bertoldi, P. Promoting Energy Efficiency: Barriers, Societal Needs and Policies. Front. Energy Res. 2022, 9, 804091. [Google Scholar] [CrossRef]
- Crosbie, T.; Guy, S. En’lightening’ Energy Use: The Co-Evolution of Household Lighting Practices. Int. J. Environ. Technol. Manag. 2008, 9, 220–235. [Google Scholar] [CrossRef]
- Hafezparast Moadab, N.; Olsson, T.; Fischl, G.; Aries, M. Smart versus Conventional Lighting in Apartments—Electric Lighting Energy Consumption Simulation for Three Different Households. Energy Build. 2021, 244, 111009. [Google Scholar] [CrossRef]
- Ministry of Housing, Communities and Local Government; Department for Levelling Up, Housing and Communities; Ministry of Housing, Communities & Local Government (2018 to 2021). Approved Document L: Conservation of Fuel and Power—Volume 1: Dwellings. Building Regulations 2010, 2021 Edition (Incorporating 2023 Amendments). Available online: https://www.gov.uk/government/publications/conservation-of-fuel-and-power-approved-document-l (accessed on 24 March 2026).
- Aliparast, S.; Onaygil, S. A Field Study of Individual, Energy-Efficient, and Human-Centered Indoor Electric Lighting: Its Impact on Comfort and Visual Performance in an Open-Plan Office. Buildings 2024, 14, 936. [Google Scholar] [CrossRef]
- Mukherjee, B.; Boubekri, M. Sustainable Architecture and Human Health: A Case for Effective Circadian Daylighting Metrics. Buildings 2025, 15, 315. [Google Scholar] [CrossRef]
- Huebner, G.M.; Hanmer, C.; Zapata-Webborn, E.; Pullinger, M.; McKenna, E.J.; Few, J.; Elam, S.; Oreszczyn, T. Self-Reported Energy Use Behaviour Changed Significantly during the Cost-of-Living Crisis in Winter 2022/23: Insights from Cross-Sectional and Longitudinal Surveys in Great Britain. Sci. Rep. 2023, 13, 21683. [Google Scholar] [CrossRef] [PubMed]
- Steffy, G. Architectural Lighting Design, 3rd ed.; Wiley & Sons, Inc.: Hoboken, NJ, USA, 2008; ISBN 978-0-470-11249-6. [Google Scholar]
- Cho, Y.; Ryu, S.-H.; Lee, B.R.; Kim, K.H.; Lee, E.; Choi, J. Effects of Artificial Light at Night on Human Health: A Literature Review of Observational and Experimental Studies Applied to Exposure Assessment. Chronobiol. Int. 2015, 32, 1294–1310. [Google Scholar] [CrossRef] [PubMed]
- Cajochen, C.; Freyburger, M.; Basishvili, T.; Garbazza, C.; Rudzik, F.; Renz, C.; Kobayashi, K.; Shirakawa, Y.; Stefani, O.; Weibel, J. Effect of Daylight LED on Visual Comfort, Melatonin, Mood, Waking Performance and Sleep. Light. Res. Technol. 2019, 51, 1044–1062. [Google Scholar] [CrossRef]
- Crespo, M.T.; Trebucq, L.L.; Senna, C.A.; Hokama, G.; Paladino, N.; Agostino, P.V.; Chiesa, J.J. Circadian Disruption of Feeding-Fasting Rhythm and Its Consequences for Metabolic, Immune, Cancer, and Cognitive Processes. Biomed. J. 2025, 48, 100827. [Google Scholar] [CrossRef] [PubMed]
- IES TM-30-20; IES Method for Evaluating Light Source Color Rendition. Illuminating Engineering Society (IES): New York, NY, USA, 2020.
- EN 12464-1:2021; Light and Lighting—Lighting of Work Places—Part 1: Indoor Work Places. European Committee for Standardisation (CEN): Brussels, Belgium, 2021.
- Trząski, A.; Rucińska, J. Integration of Daylight in Building Design as a Way to Improve the Energy Efficiency of Buildings. Energies 2025, 18, 4113. [Google Scholar] [CrossRef]
- Zocchi, G.; Hosseini, M.; Triantafyllidis, G. Exploring the Synergy of Advanced Lighting Controls, Building Information Modelling and Internet of Things for Sustainable and Energy-Efficient Buildings: A Systematic Literature Review. Sustainability 2024, 16, 10937. [Google Scholar] [CrossRef]
- International WELL Building Institute (IWBI). The WELL Building Standard, Version 2 (WELL V2); IWBI: New York, NY, USA, 2025; Available online: https://v2.wellcertified.com/en (accessed on 24 March 2026).
- CIE S 026/E:2018; CIE System for Metrology of Optical Radiation for IpRGC-Influenced Responses to Light. Commission Internationale de l’Éclairage (CIE): Vienna, Austria, 2018. [CrossRef]
- Lucas, R.J.; Peirson, S.N.; Berson, D.M.; Brown, T.M.; Cooper, H.M.; Czeisler, C.A.; Figueiro, M.G.; Gamlin, P.D.; Lockley, S.W.; O’Hagan, J.B.; et al. Measuring and Using Light in the Melanopsin Age. Trends Neurosci. 2014, 37, 1–9. [Google Scholar] [CrossRef] [PubMed]








| Room Type | Target/Requirement (Lux Level) | Uniformity |
|---|---|---|
| Living Room | 100–300 | ≥40 |
| Bedroom | 100–200 | ≥40 |
| Bathroom | 150–300 | ≥60 |
| Kitchen | 200–500 | ≥60 |
| Lighting Scene | Model 1: Existing Design Details and Results | Model 2: Proposed Design (DIALux) Details and Results |
|---|---|---|
| LS1 | Living—20 W CFL luminaire with a luminous efficacy of 60 lm/W, CRI 80, and CCT 3000 KBedroom—15 W CFL luminaire with a luminous efficacy of 60.2 lm/W, CRI 80, and CCT 3000 K Bathroom—12 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living—10 W LED luminaire with a luminous efficacy of 102 lm/W, CRI 80, and CCT 3000 KBedroom—10 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Bathroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS2 | Living, kitchen, and bedroom—12 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBathroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living, kitchen—10 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bathroom—3 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS3 | Living and bedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 80 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—8 W LED luminaire with a luminous efficacy of 80 lm/W, CRI 80, and CCT 3000 KBathroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS4 | Living and bedroom—10 W LED luminaire with a luminous efficacy of 80 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 80 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—12 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS5 | Living and kitchen—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bathroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living and kitchen—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom—5 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bathroom—3 W LED luminaire with a luminous efficacy of 80 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS6 | Living—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KEntrance—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bathroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living and entrance—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Bathroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS7 | Living, entrance and kitchen—20 W CFL luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom and bathroom—10 W CFL luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living, entrance, kitchen and bedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS8 | Living and bedroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—5 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS9 | Living—13 W CFL luminaire with a luminous efficacy of 60.2 lm/W, CRI 80, and CCT 3000 KBedroom and bathroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom and bathroom—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS10 | Living and bedroom—18 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBathroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBathroom—5 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS 11 | Living—15 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBedroom—8 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K Bathroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom and bathroom—8 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS12 | Living—10 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom—13 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K Kitchen—5 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living and kitchen—5 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 KBedroom—3 W LED luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS13 | Living and kitchen—12 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBedroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K Bathroom—12 W CFL luminaire with a luminous efficacy of 85 lm/W, CRI 80, and CCT 3000 K ![]() | Living—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Bathroom—3 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS14 | Living and bedroom—20 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBathroom—12 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Bathroom—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS 15 | Living, bedroom and kitchen—20 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBathroom—8 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living and kitchen—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom and bathroom—10 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS 16 | Living and bedroom—13 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KKitchen—20 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K Bathroom—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Kitchen—10 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Bathroom—3 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS17 | Living and kitchen—15 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBed—20 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K Bathroom—10 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() | Living, bedroom and kitchen—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS 18 | Living—20 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBed—15 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K Bathroom—8 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS 19 | Living and bedroom—13 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBathroom—10 LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() | Living and bedroom—5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBathroom—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| LS20 | Living and kitchen—10 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 KBedroom—12 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K Bathroom—13 W CFL luminaire with a luminous efficacy of 65 lm/W, CRI 80, and CCT 3000 K ![]() | Living and kitchen—8 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 KBedroom—7.5 W LED luminaire with a luminous efficacy of 100 lm/W, CRI 80, and CCT 3000 K ![]() |
| Lighting Scene | Existing Energy Consumption (kWh) † | Energy Consumption After Applying DIALux (kWh) † | % Energy Reduction |
|---|---|---|---|
| LS 1 | 10.06 | 8.81 | −12% |
| LS2 | 12.11 | 9.52 | −21% |
| LS 3 | 12.09 | 9.93 | −18% |
| LS 4 | 9.93 | 7.41 | −25% |
| LS 5 | 10.74 | 8.54 | −20% |
| LS 6 | 11.48 | 10 | −13% |
| LS 7 | 10 | 7.45 | −26% |
| LS 8 | 9.91 | 11.84 | +19% * |
| LS 9 | 9.89 | 7.61 | −23% |
| LS 10 | 9.9 | 6.95 | −30% |
| LS 11 | 9.72 | 8.54 | −12% |
| LS 12 | 10 | 8.21 | −18% |
| LS 13 | 10.776 | 8.92 | −17% |
| LS 14 | 9.81 | 8.28 | −16% |
| LS 15 | 9.72 | 9.62 | −1% |
| LS 16 | 9.71 | 8.92 | −8% |
| LS 17 | 9.72 | 7.21 | −26% |
| LS 18 | 9.55 | 9.82 | +3% * |
| LS 19 | 10.2 | 8.1 | −21% |
| LS 20 | 10.34 | 9.12 | −12% |
| Data Sample | Mean | Variance | Standard Deviation |
|---|---|---|---|
| Calculated existing energy consumption | 10.25428 | 0.55338 | 0.743867 |
| Calculated DIALux simulated consumption | 8.68047 | 1.33819 | 1.1568037 |
| Lighting Scene | Living | Kitchen | Bedroom | Bathroom | ||||
|---|---|---|---|---|---|---|---|---|
| Average Lux Levels | Compliance († C/NC) | Average Lux Levels | Compliance (C/NC) | Average Lux Levels | Compliance (C/NC) | Average Lux Levels | Compliance (C/NC) | |
| LS 1 | 105 | C | 105 | NC | 81 | NC | 247 | C |
| LS2 | 220 | C | 220 | NC | 102 | C | 220 | C |
| LS 3 | 123 | C | 123 | NC | 140 | C | 210 | C |
| LS 4 | 206 | C | 206 | NC | 139 | C | 151 | C |
| LS 5 | 213 | C | 239 | C | 141 | C | 127 | NC |
| LS 6 | 195 | C | 195 | NC | 77 | NC | 238 | C |
| LS 7 | 103 | C | 124 | NC | 110 | C | 134 | NC |
| LS 8 | 106 | C | 106 | NC | 139 | C | 251 | C |
| LS 9 | 173 | C | 173 | NC | 115 | C | 212 | C |
| LS 10 | 165 | C | 165 | NC | 114 | C | 179 | C |
| LS 11 | 136 | C | 136 | NC | 123 | C | 118 | NC |
| LS 12 | 183 | C | 231 | C | 149 | C | 234 | C |
| LS 13 | 158 | C | 251 | C | 189 | C | 236 | C |
| LS 14 | 125 | C | 125 | NC | 132 | C | 218 | C |
| LS 15 | 158 | C | 231 | C | 189 | C | 226 | C |
| LS 16 | 107 | C | 192 | NC | 177 | C | 186 | C |
| LS 17 | 131 | C | 218 | C | 130 | C | 235 | C |
| LS 18 | 167 | C | 167 | NC | 179 | C | 186 | C |
| LS 19 | 131 | C | 131 | NC | 71 | NC | 216 | C |
| LS 20 | 158 | C | 122 | NC | 189 | C | 236 | C |
| Lighting Scene | Living | Kitchen | Bedroom | Bathroom | ||||
|---|---|---|---|---|---|---|---|---|
| Average Lux Levels | Compliance († C/NC) | Average Lux Levels | Compliance (C/NC) | Average Lux Levels | Compliance (C/NC) | Average Lux Levels | Compliance (C/NC) | |
| LS 1 | 241 | C | 241 | NC | 206 | C | 237 | C |
| LS2 | 221 | C | 321 | C | 198 | C | 329 | C |
| LS 3 | 190 | C | 190 | NC | 178 | C | 235 | C |
| LS 4 | 233 | C | 233 | NC | 180 | C | 251 | C |
| LS 5 | 247 | C | 240 | C | 173 | C | 237 | C |
| LS 6 | 141 | C | 141 | NC | 135 | C | 268 | C |
| LS 7 | 193 | C | 269 | C | 170 | C | 261 | C |
| LS 8 | 137 | C | 137 | NC | 160 | C | 214 | C |
| LS 9 | 211 | C | 211 | C | 149 | C | 221 | C |
| LS 10 | 189 | C | 189 | NC | 164 | C | 234 | C |
| LS 11 | 210 | C | 210 | C | 151 | C | 254 | C |
| LS 12 | 208 | C | 225 | C | 153 | NC | 347 | C |
| LS 13 | 114 | NC | 215 | C | 170 | C | 276 | C |
| LS 14 | 193 | C | 193 | NC | 180 | C | 251 | C |
| LS 15 | 124 | NC | 215 | C | 163 | C | 247 | C |
| LS 16 | 147 | C | 227 | C | 135 | NC | 236 | C |
| LS 17 | 171 | C | 218 | C | 169 | C | 224 | C |
| LS 18 | 214 | C | 214 | C | 238 | C | 296 | C |
| LS 19 | 170 | C | 170 | NC | 126 | C | 233 | C |
| LS 20 | 156 | C | 218 | C | 130 | NC | 245 | C |
| Sample | Mean | Variance | Standard Deviation |
|---|---|---|---|
| Existing design | 165.86 | 2305.31 | 48.013 |
| Proposed design | 205.14 | 2350.55 | 48.482 |
| (a) Performance outcomes | |||
| Parameter | Existing Manual Design (CFL) | Proposed DIALux Design (LED) | Change |
| Mean energy consumption | 10.25 kWh † | 8.68 kWh | −15.3% (t = 5.12, p = 1.2 × 10−5, d = 1.61) |
| Mean illuminance | 165.86 lux | 205.14 lux | +23.7% (t = 3.084, p = 1.0 × 10−6, d = 0.81) |
| CIBSE LG9 compliance | Partial | Improved | Higher proportion of scenes compliant |
| Luminaire technology | CFL (60–65 lm/W) | LED (80–102 lm/W) | Higher efficacy |
| Design method | Manual lumen method | DIALux Evo simulation | Optimised placement and quantity |
| (b) Recommended practitioner steps for residential retrofit | |||
| Step | Recommended Action for Residential Retrofit | ||
| 1 | Replace CFL luminaires with LED equivalents (minimum 80 lm/W, CRI ≥ 80, CCT 3000 K) | ||
| 2 | Model existing room geometry in DIALux Evo using manufacturer-supplied photometric files | ||
| 3 | Set CIBSE LG9 illuminance and uniformity targets as design compliance constraints | ||
| 4 | Optimise luminaire quantity, placement, and distribution to meet targets at minimum installed load | ||
| 5 | Verify energy consumption output and compare against existing design baseline | ||
| 6 | Check compliance against EN 12464-1 and Part L requirements before finalising | ||
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Qureshi, J.; Hemarathne, T. Simulation-Based Visual-Comfort and Energy-Optimised Lighting Design for Residential Buildings: A Comparative Study of Manual and DIALux-Based Approaches. Buildings 2026, 16, 1591. https://doi.org/10.3390/buildings16081591
Qureshi J, Hemarathne T. Simulation-Based Visual-Comfort and Energy-Optimised Lighting Design for Residential Buildings: A Comparative Study of Manual and DIALux-Based Approaches. Buildings. 2026; 16(8):1591. https://doi.org/10.3390/buildings16081591
Chicago/Turabian StyleQureshi, Jawed, and Tharani Hemarathne. 2026. "Simulation-Based Visual-Comfort and Energy-Optimised Lighting Design for Residential Buildings: A Comparative Study of Manual and DIALux-Based Approaches" Buildings 16, no. 8: 1591. https://doi.org/10.3390/buildings16081591
APA StyleQureshi, J., & Hemarathne, T. (2026). Simulation-Based Visual-Comfort and Energy-Optimised Lighting Design for Residential Buildings: A Comparative Study of Manual and DIALux-Based Approaches. Buildings, 16(8), 1591. https://doi.org/10.3390/buildings16081591