Systematic Review

Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications

1
Department of Clinical Medicine and Surgery, University of Naples “Federico II”, 80138 Naples, Italy
2
Hepatobiliary and Pancreatic Surgery Unit, Department of General Surgery, Pineta Grande Hospital, 81030 Castel Volturno, Italy
3
Department of Medicine and Health Science “V. Tiberio”, University of Molise, 86100 Campobasso, Italy
4
School of Medicine and Surgery, University of Milano-Bicocca, 20126 Monza, Italy
5
Division of General and Minimally Invasive Surgery, Department of Surgery, San Giovanni Battista Hospital, 06034 Foligno, Italy
6
Minimally Invasive and Robotic Surgery Unit, San Matteo Hospital, 06049 Spoleto, Italy
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Cancers 2025, 17(5), 872; https://doi.org/10.3390/cancers17050872
Submission received: 15 January 2025 / Revised: 13 February 2025 / Accepted: 24 February 2025 / Published: 3 March 2025

Simple Summary

Indocyanine green (ICG) fluorescence has become a crucial tool in liver surgery due to its real-time navigation capabilities and low toxicity. Initially used for liver function assessment, it now plays a significant role in tumor detection, liver segmentation, and bile leak visualization. This systematic review, conducted following PRISMA guidelines, analyzed 140 studies comprising 3739 patients to evaluate ICG dosage and timing protocols. The most common dosage for tumor detection was 0.5 mg/kg, administered days to weeks before surgery. Tumor detection rates averaged 87.4%, with a 10.5% false-positive rate. Various near-infrared (NIR) camera systems were used, with the PINPOINT system being the most frequently cited. Other applications included bile leak detection, lymph node mapping, and vascular and biliary structure visualization. The findings highlight ICG fluorescence as a valuable tool in liver surgery, with the standardization of protocols potentially enhancing its efficacy and reliability for improved patient outcomes.

Abstract

Background: Indocyanine green (ICG) fluorescence has seen extensive application across medical and surgical fields, praised for its real-time navigation capabilities and low toxicity. Initially employed to assess liver function, ICG fluorescence is now integral to liver surgery, aiding in tumor detection, liver segmentation, and the visualization of bile leaks. This study reviews current protocols and ICG fluorescence applications in liver surgery, with a focus on optimizing timing and dosage based on clinical indications. Methods: Following PRISMA guidelines, we systematically reviewed the literature up to 27 January 2024, using PubMed and Medline to identify studies on ICG fluorescence used in liver surgery. A systematic review was performed to evaluate dosage and timing protocols for ICG administration. Results: Of 1093 initial articles, 140 studies, covering a total of 3739 patients, were included. The studies primarily addressed tumor detection (40%), liver segmentation (34.6%), and both (21.4%). The most common ICG fluorescence dose for tumor detection was 0.5 mg/kg, with administration occurring from days to weeks pre-surgery. Various near-infrared (NIR) camera systems were utilized, with the PINPOINT system most frequently cited. Tumor detection rates averaged 87.4%, with a 10.5% false-positive rate. Additional applications include the detection of bile leaks, lymph nodes, and vascular and biliary structures. Conclusions: ICG fluorescence imaging has emerged as a valuable tool in liver surgery, enhancing real-time navigation and improving clinical outcomes. Standardizing protocols could further enhance ICG fluorescence efficacy and reliability, benefitting patient care in hepatic surgeries.

1. Background

Over the past few decades, indocyanine green (ICG) fluorescence has greatly evolved and has achieved extraordinary diffusion in many medical and surgical fields [1,2,3,4,5,6,7]. ICG is a water-soluble fluorescent dye that is metabolized by the liver and extracted through bile ducts, with a half-life of three minutes after systematic injection [8]. Furthermore, it is minimally toxic (nausea and pyrexia were rarely reported) and it represents a suitable contrast agent for real-time navigation due to its 820 nm near-infrared (NIR) emission wavelength, minimizing interference from blood and tissue autofluorescence at 500–600 nm [8].
From early ICG application in 1950, it was largely used to assess liver function and perform surgical strategies based on Future Remnants Liver (FRL) and in other abdominal surgeries to identify tumors and lymphatic mapping and to evaluate organ and anastomosis perfusions [9].
In 2008, Aoki et al. [1] described the first application of ICG fluorescence through its intraoperative portal injection to identify hepatic segments. In 2013, Ishazawa et al. [10] definitively showcased the utility of ICG fluorescence when administered during the preoperative period. Starting with those publications, the effectiveness and safety of ICG have been further reported by many authors [4,7,11,12,13,14] who have enlightened its value in detecting tumors, either on liver surfaces or surgical specimens. Thanks to its broad availability and cost-effectiveness, ICG has been an increasing diffusion [15].
In the last 10 years, due to the widespread of robotic platforms [16,17,18,19,20,21,22,23,24] and the improvement in laparoscopic optics, ICG fluorescence has also been widely adopted in Western countries, especially in liver and colorectal surgery [8,25,26,27,28,29,30].
However, many limitations were described: the depth of liver tissue detectable is approximately less than 10 mm [31], and in patients with a poor ICG fluorescence retention rate (i.e., decreased clearance function of the liver), the fluorescence signal of the non-cancerous liver parenchyma was higher [32]. These findings impact the adequate tumor contrast, especially when ICG fluorescence was administered to patients affected by cirrhosis or steatosis or those who had undergone neoadjuvant chemotherapy.
Hence, ICG clinical application is still not well standardized. Consequently, our purpose was to examine the current evidence and explore the practical uses of ICG fluorescence for tumor detection, hepatic segmentation, bile leak identification, and lymph nodes mapping, carrying out a literature review of the timing of administration and dosage in several liver surgery applications and diseases.

2. Material and Methods

2.1. Literature Review

Our systematic review included articles published until 27 January 2024, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [33] and Assessing the methodological quality of Systematic Reviews (AMSTAR) [34].
This systematic review has been registered in the International Prospective Register for Systematic Reviews—PROSPERO, with registration number CRD42024581500.
We conducted a comprehensive search of PubMed and Medline databases to find original English papers focusing on ICG fluorescence uses in clinical studies related to liver surgery. Studies were selected using the following medical subject headings (MeSH): ((ICG fluorescence [Title]) OR (indocyanine green [Title])) AND (((liver) OR (liver surgery) OR (liver resection [Title]) OR (liver transplantation [Title]))). Furthermore, the search strategy was flexibly modified based on the specific database requirements, and further expanded by thoroughly identifying potential references from the screened texts. All authors discussed and approved the search strategy.
All anatomic, cadaveric, and surgical studies on ICG fluorescence in liver surgery were analyzed. An early exclusion was performed based on titles and abstracts by three authors (P.A., S.S., and M.R.). Furthermore, duplicates were left out. At least two blinded authors (S.S. and M.R.) used Rayyan to identify and analyze relevant studies [35]. Disagreements on article selection were resolved by discussion and consensus among the authors. All reports obtained from the databases will be exported to the reference management EndNote software (EndNote™ 21 version, Clarivate, Philadelphia, PA, USA). The duplicated reports were managed according to the Bramer et al. method [36]. The final review of the articles was carried out in April 2024.

2.2. Inclusion Criteria

The main study objectives have been formulated according to the Patients, Intervention, Comparison, and Outcomes method [37] (Table 1). English language, human studies, and full-text available studies were included only if the dose and timing of ICG fluorescence administration were clearly described. Comparative studies, case series, and case reports that met these inclusion criteria were involved. All benign and malignant liver neoplasms were collected (Hepatocellular Carcinoma (HCC), Cholangiocarcinoma (CCA), Colorectal Liver Metastases (CRLM), Primary Liver Cancer (PLC), Focal Nodular Hyperplasia (FNH), Gastrointestinal Stromal Tumor (GIST), Squamous Cell Carcinoma (SCC), and Liver Transplant (LT)).

2.3. Exclusion Criteria

Studies involving animal experiments, studies published in languages other than English, conference abstracts, editorials, expert opinions, and review papers were excluded. Patients’ sample size, age, and surgical approaches (open, laparoscopic, and/or robotic surgery) do not represent exclusion criteria.

2.4. Data Extraction and Endpoints

Reports were divided into three distinct groups, namely irrelevant, relevant, and unsure. Studies determined to be irrelevant by both reviewers were excluded, while papers that were relevant or unsure by at least one reviewer were analyzed thanks to a full-text evaluation.
A PRISMA flow chart documented the entire search and selection process (Figure 1).
Using a standardized data extraction form, all authors recorded key details for each study, such as the first author, year of publication, study design, total number of patients, type of surgery (open, laparoscopy, or robotic surgery), type of laparoscopic/robotic system, type of NIR, liver disease, age, percentage of patients affected by cirrhosis, ICG fluorescence dose (mg/kg or mL), timing of administration, type of navigation (tumor detection, segmentation or other uses), and percentage of major hepatectomies (≥3 liver segments resection). In the case of missing information, the authors performed calculations based on the available data.
Data were divided into six tables (Tables S1–S6) according to different ICG fluorescence uses.
The primary endpoint was to evaluate the dosing and timing of ICG fluorescence in liver surgery in tumor detection. In order to achieve data about liver segmentation, we analyzed the direct portal ICG injection under percutaneous-guided ultrasound, defined as the “positive staining” technique or the “negative staining” technique obtained through an intravenous ICG dye injection after segmental portal pedicle clamp, following the Glissonian approach [38].
Our secondary endpoint was to collect data regarding other possible ICG fluorescence applications in clinical practices, such as bile leak, bile duct visualization, hepatic artery embolization, and lymph node sentinel.

2.5. Ethical Issues

Ethical approval or informed consent is not required since this systematic review will be based only on previously published studies and does not imply any direct contact with individual subjects.

3. Results

A total of 1093 articles were initially obtained (Figure 1). According to exclusion criteria, 957 studies were excluded because they were not relevant or duplicates. After the addition of 4 hand-searched studies, 140 articles were finally selected [1,6,10,12,13,14,26,27,28,31,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73,74,75,76,77,78,79,80,81,82,83,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99,100,101,102,103,104,105,106,107,108,109,110,111,112,113,114,115,116,117,118,119,120,121,122,123,124,125,126,127,128,129,130,131,132,133,134,135,136,137,138,139,140,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,162,163,164,165,166,167,168]: 2 comparative studies, 1 case series, 26 case reports, 1 case-matched study, 1 cohort study, 75 retrospective studies, 6 Randomized Clinical Trials (RCTs), 18 prospective studies, 1 post hoc analysis of a prospective study, and 9 types of study not specified. The cumulative study population encompassed 3739 patients. The publication period ranges from 2009 to 2024. The PRISMA flow diagram outlining the study selection process is presented in Figure 1.
Several types of NIR cameras were used by authors: the PINPOINT system/1588 Advanced Imaging Modalities Platform (Stryker Co., Kalamazoo, MI, USA) was the most frequent available system (45 studies, 31.9%), followed by Photodynamic Eye (Hamamatsu Photonics Co., Shizuoka, Japan) (24 reports, 17%). The Firefly system (Intuitive Surgical Inc., Sunnyvale, CA, USA) was used in 16 articles (11.3%) for robotic surgery. Nevertheless, other NIR types were not available in 56 (39.7%) studies (Tables S1–S6). Several clinical applications of ICG fluorescence were reported: 56 articles (40%) described tumor detection ability, 47 articles (33.6%) described liver segmentation ability, and in 30 (21.4%) articles, the authors experienced both applications. Limited experiences are reported in bile leak detection five (3.6%) articles. Seven articles (5%) reported other uses. The type of surgery (open vs. minimally invasive surgery) and clinical application of ICG fluorescence are summarized in Figure 2. As reported in Tables S1–S6, cirrhotic patients were included in many studies, with a percentage of liver cirrhosis with available data of 47.8%.
ICG fluorescence was administered preoperatively, intraoperatively, and in both periods. The dose most frequently used was 0.5 mg/kg (Tables S1–S6). Generally, ICG fluorescence was administered within 14 days before the operation day, especially within 3 days in many of the studies. An additional administration (0.02–0.5 mg/kg) was described as an option in case of the long interval between the administration and operation day. Finally, the median tumor detection rate was reported to be 87.4% (43–100%), and the median false-positive rate was reported to be 10.5% (0–31.3%).
The negative staining method was reported in 55 (39%) articles. Most authors performed this technique using 2.5 mg/body (range 0.025–25 mg/body) intravenously. Conversely, 35 (24.8%) articles carried out the positive staining approach, frequently using an ICG fluorescence dose of 0.25 mg/body (range 0.025–12.5 mg/body).
Eight studies reported an innovative application of ICG fluorescence during real-time liver navigation. Overall, 5 (3.6%) out of 140 articles described intraoperative injection of ICG fluorescence to detect bile leaks, either in open or minimally invasive liver surgery (Table S5).

3.1. ICG Fluorescence Imaging for HCC Detection

Generally, HCC lesions exhibit total tumor fluorescence upon superficial examination (Figure 3). However, discrepancies were noted when comparing surface observations with sectional views. Cases where surface and sectional fluorescence patterns were consistent predominantly involved tumors exposed on the hepatic surface. Contrarily, tumors located deeper within the liver showed total fluorescence superficially but partial or rim fluorescence upon sectioning, suggesting that tumor depth influences ICG fluorescence imaging clarity.
Nevertheless, poorly differentiated HCCs showed variations in fluorescence patterns (partial or rim-type), maybe due to slower ICG excretion in less differentiated cancer cells.

3.2. ICG Fluorescence for CRLM Detection

In CRLM, ICG fluorescence imaging shows characteristic rim fluorescence patterns: fluorescence is primarily observed in non-tumor cells at the periphery, while tumor cells in the central region remain non-fluorescent (Figure 3).
Superficially, CRLM lesions often exhibited total fluorescence, but discrepancies emerged when comparing surface and sectional views. Tumors located closer to the hepatic surface generally displayed consistent fluorescence patterns between surface and cross-sectional imaging, whereas deeper lesions appeared fluorescent superficially but exhibited partial or rim fluorescence upon sectioning. Additionally, larger and more fibrotic CRLM lesions tended to show greater heterogeneity in fluorescence distribution, possibly due to altered vascularization and ICG uptake dynamics in metastatic tissue.

3.3. ICG Fluorescence for CCA Detection

In CCA, ICG fluorescence imaging typically revealed a rim fluorescence pattern, with fluorescence primarily observed in non-tumor cells surrounding the lesion, while tumor cells in the central region remained non-fluorescent (Figure 3). This peripheral fluorescence is likely due to ICG uptake by peritumoral hepatocytes and retention in fibrotic stromal components rather than direct tumor cell accumulation.
Superficially, as reported for CRLM, CCA lesions often appeared fluorescent, but inconsistencies arose when comparing surface and sectional views. Additionally, poorly differentiated ICC and tumors with extensive fibrosis exhibited greater heterogeneity in fluorescence patterns, possibly due to reduced ICG penetration and altered vascular permeability within the tumor microenvironment.

4. Discussion

In the last decades, ICG fluorescence has been used to assess the hepatic and choroidal blood flow and the measurement of cardiac output [3,4,9]. The main advantage of ICG fluorescence imaging is its non-invasive nature and real-time capability and it does not require direct manipulation of vessels or prolonged imaging times, reducing intraoperative time and potential complications associated with invasive techniques. Furthermore, the safety profile of ICG fluorescence is well-established, with minimal allergic reactions or adverse effects reported in clinical practice.
Nevertheless, the standardization of dosage and timing of administration still represent crucial issues in a challenging scenario such as Hepato-pancreatic and Biliary (HPB) surgery. It could be linked to several preferred dosages and timing and the lack of literature data due to the heterogeneity of populations, devices, and tumor features. Furthermore, age and liver texture could impact intraoperative ICG fluorescent emission and visualization. Based on these findings, a consensus statement on ICG fluorescence used in liver surgery is a key prospect for the future.
Nevertheless, the European Association for Endoscopic Surgery (EAES) published a consensus conference with several statements for ICG application in abdominal surgery, including HPB [9].
Given the well-established effectiveness of ICG fluorescence in improving clinical outcomes [80,124,131,145,150], our review offers a flowchart of ICG fluorescence application based on the most used dosages and timing for hepatic neoplasm identification, liver segmentation, and bile leak visualization during open and minimally invasive surgery (Figure 4).

4.1. Tumor Detection

The application of ICG fluorescence imaging in HPB surgery has been widely explored, demonstrating utility in tumor detection and the dose and timing of its administration differ significantly across studies. The lack of ICG fluorescence in healthy tissue represents a real-time guide for the dissection plane, allowing for higher R0 resection rates. A common dosing strategy involves administering 0.5 mg/kg of ICG fluorescence preoperatively.
The previous studies by Gotoh et al. [6] and Ishizawa et al. [13] reported a clinical experience in a limited number of patients (10 and 26 patients, respectively) affected by HCC using a 0.5 mg/kg dose with a timing range of 1–8 days before open liver surgery. Contrarily, Uchiyama et al. [39] and Peloso et al. [41] performed liver resection after administration of 0.5 mg/kg of ICG fluorescence with a timing of 2 weeks and 24 h before surgery, respectively, in open surgeries for CRLM.
Following these early experiences, several studies explored different doses and timings to optimize detection (Table S1). Van der Vorst et al. [44] conducted a Randomized Clinical Trial (RCT) involving 40 patients and compared 10 mg and 20 mg doses administered 24 or 48 h before surgery for CRLM detection, highlighting that variations in dosing and timing can be tailored based on specific clinical needs and tumor types.
As reported in Table S1, ICG fluorescence imaging has been employed in both open and minimally invasive surgeries, demonstrating its versatility. The retrospective study by Kudo et al. [45] utilized ICG fluorescence in minimally invasive surgeries for HCC and CRLM, with a dose of 0.5 mg/kg administered within 2 weeks preoperatively.
An interesting application was reported by Tummers et al. [47] who used ICG in a case report involving minimally invasive surgeries for melanoma, using a 10 mg dose administered 1 day before surgery.
As reported in recent consensus on ICG fluorescence-guided surgery by Casinotti et al. [9], ICG fluorescence aids in identifying subcapsular and superficial tumors, as well as deeper lesions, and in locating unknown glissonian tumors and ensuring anatomical resection margins. Considering these findings, several studies compared ICG fluorescence application to Intra-Operative UltraSound (IOUS) [145].
While IOUS is widely considered the gold standard for tumor detection, ICG use has demonstrated superior accuracy in identifying lesions smaller than 2 mm [26]. IOUS and ICG combination increase the sensitivity in locating superficial lesions [6,28].
Nevertheless, in cirrhotic and hardened liver ICG fluorescence can be especially beneficial due to difficult IOUS interpretation and untrustworthy tactile feedback. In addition, in this group, the interval between ICG fluorescence administration and surgery is longer due to a higher ICG fluorescence retention rate when compared to healthy livers (Figure 4).
Many studies demonstrated the different penetration of ICG fluorescence through liver tissue: total or partial fluorescence staining pattern is generally due to HCC, while rim fluorescence staining pattern is detected mainly in metastases. Different characteristics of penetration are described for CCA due to there being no predominant staining pattern.
Although Handgraaf et al. [55] and Zhou et al. [138] hold up the false positive in tumor detection due to the non-specific uptake of lesions with consequent benign lesion resections, similar findings are reported by Nishino et al. [102] who emphasized the need for careful intraoperative assessment.
Frantz et al. [26] also retrieved a peritoneal metastasis in one patient affected by HCC. The ICG fluorescence dose was similar to other patients included in their study. No other superimposable experiences were found in the literature review.

4.2. Segmentation

The application of ICG fluorescence imaging for liver segmentation during HPB surgery has been the subject of numerous studies, as listed in Table S2.
ICG fluorescence imaging has shown significant efficacy in intraoperative liver segmentation, and it is crucial for precise surgical interventions. The dosing and timing of ICG fluorescence administration vary considerably across studies. Timing also varied, with most authors opting for intraoperative administration (Figure 4).
Aoki et al. [1], involving 35 patients undergoing open surgery for various liver diseases, demonstrated effective segmentation using 1 mL of ICG fluorescence (5 mg/mL) administered intraoperatively. In addition, Aoki et al. described the first application of direct portal injection of ICG fluorescence [1]. Furthermore, following previous experience, Aoki et al. [90] used 5 mg of intraoperative ICG fluorescence to detect positive staining in 81 patients affected by primary and secondary liver tumors who underwent minimally invasive surgery.
A lower dose was described by Uchiyama et al. [91] and Cheung et al. [135]: the authors reported successful segmentation in patients affected by HCC using an intraoperative dose of 0.5 mg/kg and 0.025 mg/kg, respectively.
Li et al. [140] performed an unusual application of ICG fluorescence: this retrospective study reported a dose of 2.5 mg intraoperatively administered for liver echinococcosis for negative staining.
Regarding negative staining, Wakabayashi et al. performed an extensive review [169] on ICG fluorescence use and they supposed that this intraoperative technique was preferred during hemi-hepatectomy, sectionectomy, and anterolateral segmentectomies, preferably using Takasaki’s extrahepatic Glissonean approach.
On the contrary, ICG-positive staining required the direct injection of ICG fluorescence into the portal branches responsible for resected territories under IOUS guidance with an 18- to 22-gauge spinal or percutaneous transhepatic cholangiodrainage needle. The injection is performed slowly to avoid ICG fluorescence retrograde flow into neighboring segments with undesired staining without hepatic artery clamping. In addition, it is necessary to assess the hepatic segment volume to be resected. For these reasons, positive staining requires IOUS skills.

4.3. Tumor Detection and Segmentation

ICG fluorescence imaging has demonstrated substantial efficacy in contemporary tumor detection and liver segmentation. The comparative study by Abo et al. [28] involving 117 patients undergoing open surgery for primary liver cancer (PLC) and CRLM showed that ICG fluorescence was effective when administered preoperatively (0.5 mg/kg) and intraoperatively (1.25 mg). The study reported effective tumor detection and segmentation, which was consistent with findings from other studies such as Terasawa et al. [133] and Zhang et al. [134], who applied similar protocols in minimally invasive surgeries.
For instance, Peyrat et al. [27] administered 0.25 mg/kg preoperatively one day prior, followed by an intraoperative dose ranging from 0.016 to 1.25 mg, achieving effective tumor detection and segmentation. Similarly, Cheung et al. [135] used a preoperative dose of 0.5 mg/kg administered 10 days prior and an intraoperative dose of 0.025 mg for segmentation and tumor detection in minimally invasive surgeries.
These variations reflect attempts to tailor ICG fluorescence usage to specific surgical contexts.
However, Zhang et al. [143] employed an RCT to compare different doses and timings, finding that preoperative administration 24–72 h before surgery combined with intraoperative doses provided optimal results.

4.4. Bile Leak Detection

ICG fluorescence imaging for the detection and management of bile leaks during HPB surgery has shown promising results, as reflected in various studies summarized in Table S5. Our discussion integrates these findings to highlight the effectiveness, application variations, and limitations of ICG fluorescence in preventing and managing bile leaks.
Sakaguchi et al. [161] conducted a cohort study with 27 patients undergoing open surgery for HCC, CRLM, and other liver diseases, utilizing a dose of 0.05 mg/mL of ICG administered intraoperatively. In detail, for the bile leak test, ICG fluorescence was slowly injected into the bile duct through a transcystic tube. The distal common bile duct was clamped. Before injection, the bile reflux using the aspiration technique was confirmed. Bile leaks were easily detected by the extra-biliary fluorescent signal using an infrared camera system (PDE; Hamamatsu Photonics KK, Hamamatsu, Japan).
Similarly, Kaibori et al. [162], in an RCT involving 102 patients, compared an ICG fluorescence control group with an ICG fluorescence PDE group, using 10 mL of a dilute ICG solution (2.5 mg/mL). The intraoperative application of ICG significantly enhanced the detection of bile leaks, leading to timely interventions and reduced postoperative complications.
Umemura et al. [163] described an unusual ICG fluorescence use in liver cyst surgery: they performed an Endoscopic Retrograde Cholangio-Pancreatography (ERCP) one day before surgery, placing a 5-Fr Endoscopic Nasal Biliary Drainage (ENBD) into the common hepatic duct. During transecting intrahepatic biliary branches, ICG (2.5 mg/mL) is injected into the biliary tract via ENBD. The ICG fluorescence imaging mode reveals intrahepatic biliary branches and unexpected small bile leakages. The authors concluded that ICG fluorescence clarifies that linear stapler sometimes fails the closure of biliary branches.
All included studies demonstrated the ability of ICG fluorescence to effectively identify bile leaks, contributing to improved surgical outcomes and reducing post-operative complications.

4.5. Liver Transplantation

ICG fluorescence imaging has been increasingly also utilized in liver transplantation to enhance visualization, assess graft quality, and predict postoperative outcomes. The following analysis discusses key studies that highlight the application and benefits of ICG fluorescence in liver transplantation.
Troisi et al. [157] presented the first case of a fully laparoscopic donor hepatectomy for pediatric liver transplantation using ICG fluorescence near-infrared fluorescence imaging in the Middle East. ICG fluorescence was injected intravenously (0.1 mg/kg) to visualize the left hepatic artery and biliary ducts within 10 s. Fluorescence imaging guided the precise cutting of the biliary ducts, enhancing visualization of biliary structures, improving the precision of the surgery, and reducing the risk of postoperative complications.
The study by Tomassini et al. [158] explores ICG fluorescence cholangiography as a method to improve visualization of intra-hepatic ducts during Pure Laparoscopic Living Donor Hepatectomy (PLDH). Overall, 11 consecutive donors underwent full laparoscopic left hepatectomy. Five different protocols of ICG-NIR-FC were tested to find the optimal dose, timing, and administration route for visualizing the biliary ducts (Table S4). The protocols varied in ICG fluorescence dosage, timing of administration relative to parenchymal transection, and whether the ICG fluorescence was administered intravenously or through the cystic duct. The effectiveness of each protocol was assessed by comparing standard preoperative and intraoperative cholangiography images with ICG-NIR-FC images. Despite two protocols (B and E) providing outcomes comparable to standard intraoperative cholangiography, ICG fluorescence did not show clear superiority in identifying segmental small ducts, particularly due to the limited penetration depth of NIR light (5–10 mm).
The Panaro et al. [159] study evaluates ICG fluorescence angiography during liver and pancreas transplantation to guide intraoperative decisions. The study focuses on ICG fluorescence use in assessing graft biliary duct perfusion in liver transplants and duodenal stump perfusion in pancreas transplants. Both in liver and in pancreatic transplantation, ICG fluorescence was injected intravenously at 0.5 mg/kg. In two out of six (33.33%) liver transplantations, the intraoperative strategy was changed based on ICG fluorescence findings, leading to additional graft bile duct resections, while one of five (20%) pancreas transplantations required duodenal stump resection due to ischemia detected by ICG fluorescence.
The procedure extended the operative time by approximately 10 min in liver transplantation and 8 min in pancreas transplantation. The authors concluded that ICG fluorescence angiography provides real-time objective information on organ perfusion, which is crucial for reducing ischemic complications in transplantation.
Kim et al. [160] investigated ICG near-infrared fluorescence imaging to enhance liver midplane demarcation during PLHD. This retrospective analysis compared 30 donors who underwent PLDH without ICG fluorescence to 46 donors with ICG fluorescence. The authors conclude that ICG fluorescence improves the accuracy of liver dissections and reduces operation times, thus enhancing overall surgical outcomes. Furthermore, a single low-dose injection of ICG fluorescence was sufficient for both liver midplane dissection and bile duct visualization, with no need for additional injections or intraoperative cholangiography.

4.6. Other Applications

Kawaguchi et al. [166] described the technical details of bile duct visualization during laparoscopic surgery. They administered 1 mL of intravenously ICG fluorescence. Following ICG fluorescence injection, a 0-degree laparoscope was introduced through a 12-mm trocar and placed above the hepatoduodenal ligament or hilar plate. The bile ducts were identified in several conditions: identification of the confluence of the left and right hepatic ducts before dissection, identification of the left hepatic duct with severe adhesions during dissection, and identification of the peripheral bile duct with severe adhesions during parenchymal transection. The authors compared ICG fluorescence to radiographic cholangiography and concluded that ICG fluorescence imaging may save time and avoid bile duct injury due to the insertion of a tube for the injection of contrast material.
In 2020, Tanaka et al. [167] reported a case of HCC treated with laparoscopic anatomical liver. Intraoperative liver segmentation is necessary to accomplish laparoscopic anatomical liver resection. One day before surgery, surgeons performed hepatic artery embolization with an ICG-Lipiodol® mixture and Gelpart® to define the region for hepatectomy. Gelpart® prevents ICG from being quickly washed out due to blood flow. This technique allows better visualization of target segments interested in HCC. Nevertheless, Tanaka et al. reported some limitations: firstly, tumor necrosis could be reported after Lipiodol® injection due to its well-known anticancer effect. In addition, in the case of significant arteriovenous shunting or arterial communication, this approach might become more difficult. Although the ICG-Lipiodol® mixture and Gelpart® increase surgical costs, the authors reported lower hospital costs and post-operative complication rates when compared to traditional hepatectomy.
ICG fluorescence represents a key point of lymphography for colorectal cancer and Upper GastroIntestinal Malignancies [3,80,170]. As reported for gastric and breast cancer, several experiences in the literature describe the ICG fluorescence superiority when compared to radioactive tracers and dedicated probes to detect lymph nodes involved in metastatic disease. Indeed, ICG fluorescence shows a higher sensitivity in lymphatic channel evaluation involved in first tumor drainage.
Ruzzenente et al. [168] proposed the LIver SEntinel LYmph-node (LISELY) study that involved 18 patients who underwent surgery for liver and biliary duct neoplasms. The primary lymphatic outflow and the sentinel lymph node were identified by intraoperative NIR imaging with ICG fluorescence, which was detected at predetermined brief intervals. The lymphatic outflow route was visible in 14 patients (77.8%) at a median of 3 min (IQR 3–10) following ICG fluorescence injection. In 12 patients (66.7%), the sentinel lymph node was confirmed by histology testing. The authors concluded that this technique can be conducted safely and practically.

4.7. Cost Analysis

It is crucial to evaluate the associated costs to understand ICG fluorescence’s economic feasibility and the benefits that its application provides.
Direct ICG fluorescence costs depend on the supplier and the healthcare facility’s purchasing agreements. Many experiences in the literature reported costs between USD 50 to USD 250 [171,172,173]. Although the primary cost is represented by the imaging Equipment, NIR systems are mandatory to visualize ICG fluorescence and its initial purchase prices range from USD 50,000 to USD 150,000 [171], depending on the model and capabilities. Maintenance and calibration of these systems also incur additional costs.
Nevertheless, ICG fluorescence might reduce the operative time, enhancing anatomical visualization and tumor resection. For instance, Marino et al. [137,174] reported that ICG fluorescence use during robotic liver resection led to a 100% R0 resection rate, with improved detection of lesions that were missed by traditional imaging techniques [137]. The enhanced accuracy and reduced need for repeat surgeries can lead to significant cost savings over time.
According to experiences in the literature [26,108,175], these findings are directly linked to better perioperative outcomes, such as lower intra-operative and post-operative complication rates and shorter hospital stays. This, in turn, reduces the costs associated with extended hospitalizations and additional treatments.

4.8. Limitations

Despite its numerous advantages, ICG fluorescence imaging has several limitations that warrant consideration. Firstly, ICG fluorescence depends on adequate liver function and biliary excretion pathways; thus, its efficacy may be compromised in patients with severe liver dysfunction or cholestasis.
Technical limitations such as tissue depth penetration and background fluorescence interference can also affect the accuracy of ICG fluorescence imaging, particularly in obese patients or those with significant intra-abdominal scarring.
Secondly, while ICG fluorescence provides valuable information on vascular perfusion, it does not substitute for detailed anatomical knowledge or tactile feedback during surgery. Moreover, the cost associated with ICG fluorescence imaging systems and the need for specialized training in interpretation and utilization may limit its widespread adoption in resource-constrained settings.
Another key point is represented by serious allergic reactions or anaphylaxis that could be investigated in further RCT.

5. Conclusions

This systematic review highlights the significant role of ICG fluorescence in liver surgery, emphasizing its multifaceted applications such as tumor identification, segmentation, bile leak evaluation, metastatic lymph node detection, and liver transplantation. These advantages contribute to reduced operative time and minimized complications compared to traditional invasive techniques. Despite its established safety and effectiveness, challenges remain in the variability of different tumor types or varying degrees of liver dysfunction, particularly in complex HPB surgery settings. Future studies should aim to address the current limitations and expand the evidence base for broader clinical application, ultimately enhancing patient outcomes in hepatic surgeries.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/cancers17050872/s1: Table S1. Protocols and applications of Indocyanine Green Fluorescence to identify primary and secondary liver tumors; Table S2. Protocols and applications of Indocyanine Green Fluorescence to liver segment identifications; Table S3. Protocols and applications of Indocyanine Green Fluorescence to liver segment identifications and tumor detection; Table S4. Protocols and applications of Indocyanine Green Fluorescence during liver transplant; Table S5. Protocols and applications of Indocyanine Green Fluorescence to bile leak identifications; Table S6. Protocols and applications of Indocyanine Green Fluorescence in particular applications.

Author Contributions

P.A.: study conception and design, literature search, data acquisition, interpretation, and analysis; drafting and critically revising the article for important intellectual content; final approval of the version to be published. All authors: literature search, data acquisition, final approval of the version to be published. P.A.: drafting and critically revising the article for important intellectual content; final approval of the version to be published. P.A. and A.R.: supervision, drafted and critically revised the article for important intellectual content; final approval of the version to be published. All authors have read and agreed to the published version of the manuscript.

Funding

This work has been partially supported by National Plan for NRRP Complementary Investments D^3 4 Health: Digital Driven Diagnostics, prognostics and therapeutics for sustainable Health care.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, with undue reservation.

Conflicts of Interest

All authors declare no conflicts of interest.

References

  1. Aoki, T.; Yasuda, D.; Shimizu, Y.; Odaira, M.; Niiya, T.; Kusano, T.; Mitamura, K.; Hayashi, K.; Murai, N.; Koizumi, T.; et al. Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection. World J. Surg. 2008, 32, 1763–1767. [Google Scholar] [CrossRef] [PubMed]
  2. Barberio, M.; Felli, E.; Seyller, E.; Longo, F.; Chand, M.; Gockel, I.; Geny, B.; Swanström, L.; Marescaux, J.; Agnus, V.; et al. Quantitative fluorescence angiography versus hyperspectral imaging to assess bowel ischemia: A comparative study in enhanced reality. Surgery 2020, 168, 178–184. [Google Scholar] [CrossRef] [PubMed]
  3. Cassinotti, E.; Boni, L.; Baldari, L. Application of indocyanine green (ICG)-guided surgery in clinical practice: Lesson to learn from other organs-an overview on clinical applications and future perspectives. Updates Surg. 2023, 75, 357–365. [Google Scholar] [CrossRef]
  4. Chen, H.; Wang, Y.; Xie, Z.; Zhang, L.; Ge, Y.; Yu, J.; Zhang, C.; Jia, W.; Ma, J.; Liu, W. Application Effect of ICG Fluorescence Real-Time Imaging Technology in Laparoscopic Hepatectomy. Front. Oncol. 2022, 12, 819960. [Google Scholar] [CrossRef]
  5. Coletta, D.; Patriti, A. Don’t forget indocyanine fluorescence-guided surgery in emergency settings. Updates Surg. 2023, 75, 2047–2048. [Google Scholar] [CrossRef]
  6. Gotoh, K.; Yamada, T.; Ishikawa, O.; Takahashi, H.; Eguchi, H.; Yano, M.; Ohigashi, H.; Tomita, Y.; Miyamoto, Y.; Imaoka, S. A novel image-guided surgery of hepatocellular carcinoma by indocyanine green fluorescence imaging navigation. J. Surg. Oncol. 2009, 100, 75–79. [Google Scholar] [CrossRef]
  7. Hu, Q.; Tian, Z.; Sun, Y.; Zhang, B.; Tang, Z. Safety and efficacy of indocyanine green fluorescence imaging for real-time guidance of laparoscopic thermal ablation in patients with liver cancer. Int. J. Hyperth. 2024, 41, 2306818. [Google Scholar] [CrossRef] [PubMed]
  8. Lim, Z.Y.; Mohan, S.; Balasubramaniam, S.; Ahmed, S.; Siew, C.C.H.; Shelat, V.G. Indocyanine green dye and its application in gastrointestinal surgery: The future is bright green. World J. Gastrointest. Surg. 2023, 15, 1841–1857. [Google Scholar] [CrossRef]
  9. Cassinotti, E.; Al-Taher, M.; Antoniou, S.A.; Arezzo, A.; Baldari, L.; Boni, L.; Bonino, M.A.; Bouvy, N.D.; Brodie, R.; Carus, T.; et al. European Association for Endoscopic Surgery (EAES) consensus on Indocyanine Green (ICG) fluorescence-guided surgery. Surg. Endosc. 2023, 37, 1629–1648. [Google Scholar] [CrossRef]
  10. Ishizawa, T.; Masuda, K.; Urano, Y.; Kawaguchi, Y.; Satou, S.; Kaneko, J.; Hasegawa, K.; Shibahara, J.; Fukayama, M.; Tsuji, S.; et al. Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma. Ann. Surg. Oncol. 2014, 21, 440–448. [Google Scholar] [CrossRef]
  11. Qi, C.; Zhang, H.; Chen, Y.; Su, S.; Wang, X.; Huang, X.; Fang, C.; Li, B.; Xia, X.; He, P. Effectiveness and safety of indocyanine green fluorescence imaging-guided hepatectomy for liver tumors: A systematic review and first meta-analysis. Photodiagnosis Photodyn. Ther. 2019, 28, 346–353. [Google Scholar] [CrossRef]
  12. Tashiro, Y.; Aoki, T.; Hirai, T.; Koizumi, T.; Kusano, T.; Matsuda, K.; Yamada, K.; Nogaki, K.; Hakozaki, T.; Wada, Y.; et al. Indocyanine Green Labeling of Tumors in the Liver Recurring After Radiofrequency Ablation Enables Complete Resection by Fluorescence-guided Surgery. Anticancer. Res. 2022, 42, 1345–1350. [Google Scholar] [CrossRef] [PubMed]
  13. Ishizawa, T.; Fukushima, N.; Shibahara, J.; Masuda, K.; Tamura, S.; Aoki, T.; Hasegawa, K.; Beck, Y.; Fukayama, M.; Kokudo, N. Real-time identification of liver cancers by using indocyanine green fluorescent imaging. Cancer 2009, 115, 2491–2504. [Google Scholar] [CrossRef] [PubMed]
  14. Rocca, A.; Avella, P.; Scacchi, A.; Brunese, M.C.; Cappuccio, M.; De Rosa, M.; Bartoli, A.; Guerra, G.; Calise, F.; Ceccarelli, G. Robotic versus open resection for colorectal liver metastases in a “referral centre Hub&Spoke learning program”. A multicenter propensity score matching analysis of perioperative outcomes. Heliyon 2024, 10, e24800. [Google Scholar] [CrossRef]
  15. Strigalev, M.; Tzedakis, S.; Nassar, A.; Dhote, A.; Gavignet, C.; Gaillard, M.; Marchese, U.; Fuks, D. Intra-operative indocyanine green fluorescence imaging in hepatobiliary surgery: A narrative review of the literature as a useful guide for the surgeon. Updates Surg. 2023, 75, 23–29. [Google Scholar] [CrossRef] [PubMed]
  16. Masetti, M.; Fallani, G.; Ratti, F.; Ferrero, A.; Giuliante, F.; Cillo, U.; Guglielmi, A.; Ettorre, G.M.; Torzilli, G.; Vincenti, L.; et al. Minimally invasive treatment of colorectal liver metastases: Does robotic surgery provide any technical advantages over laparoscopy? A multicenter analysis from the IGoMILS (Italian Group of Minimally Invasive Liver Surgery) registry. Updates Surg. 2022, 74, 535–545. [Google Scholar] [CrossRef]
  17. Vicente, E.; Quijano, Y.; Ferri, V.; Caruso, R. Robot-assisted cholecystectomy with the new HUGO™ robotic-assisted system: First worldwide report with system description, docking settings, and video. Updates Surg. 2023, 75, 2039–2042. [Google Scholar] [CrossRef]
  18. Ceccarelli, G.; Andolfi, E.; Biancafarina, A.; Rocca, A.; Amato, M.; Milone, M.; Scricciolo, M.; Frezza, B.; Miranda, E.; De Prizio, M.; et al. Robot-assisted surgery in elderly and very elderly population: Our experience in oncologic and general surgery with literature review. Aging Clin. Exp. Res. 2017, 29, 55–63. [Google Scholar] [CrossRef]
  19. Ceccarelli, G.; Pasculli, A.; Bugiantella, W.; De Rosa, M.; Catena, F.; Rondelli, F.; Costa, G.; Rocca, A.; Longaroni, M.; Testini, M. Minimally invasive laparoscopic and robot-assisted emergency treatment of strangulated giant hiatal hernias: Report of five cases and literature review. World J. Emerg. Surg. 2020, 15, 37. [Google Scholar] [CrossRef]
  20. Chatterjee, S.; Das, S.; Ganguly, K.; Mandal, D. Advancements in robotic surgery: Innovations, challenges and future prospects. J. Robot. Surg. 2024, 18, 28. [Google Scholar] [CrossRef]
  21. Robinson, T.D.; Sheehan, J.C.; Patel, P.B.; Marthy, A.G.; Zaman, J.A.; Singh, T.P. Emergent robotic versus laparoscopic surgery for perforated gastrojejunal ulcers: A retrospective cohort study of 44 patients. Surg. Endosc. 2022, 36, 1573–1577. [Google Scholar] [CrossRef] [PubMed]
  22. Sucandy, I.; Attili, A.; Spence, J.; Bordeau, T.; Ross, S.; Rosemurgy, A. The impact of body mass index on perioperative outcomes after robotic liver resection. J. Robot. Surg. 2020, 14, 41–46. [Google Scholar] [CrossRef] [PubMed]
  23. Avella, P.; Vaschetti, R.; Cappuccio, M.; Gambale, F.; Meis, L.D.E.; Rafanelli, F.; Brunese, M.C.; Guerra, G.; Scacchi, A.; Rocca, A. The role of liver surgery in simultaneous synchronous colorectal liver metastases and colorectal cancer resections: A literature review of 1730 patients underwent open and minimally invasive surgery. Minerva Surg. 2022, 77, 582–590. [Google Scholar] [CrossRef]
  24. Di Benedetto, F.; Magistri, P.; Guerrini, G.P.; Di Sandro, S. Robotic liver partition and portal vein embolization for staged hepatectomy for perihilar cholangiocarcinoma. Updates Surg. 2022, 74, 773–777. [Google Scholar] [CrossRef] [PubMed]
  25. Marcellinaro, R.; Grieco, M.; Spoletini, D.; Troiano, R.; Avella, P.; Brachini, G.; Mingoli, A.; Carlini, M. How to reduce the colorectal anastomotic leakage? The MIRACLe protocol experience in a cohort in a single high-volume centre. Updates Surg. 2023, 75, 1559–1567. [Google Scholar] [CrossRef]
  26. Franz, M.; Arend, J.; Wolff, S.; Perrakis, A.; Rahimli, M.; Negrini, V.R.; Stockheim, J.; Lorenz, E.; Croner, R. Tumor visualization and fluorescence angiography with indocyanine green (ICG) in laparoscopic and robotic hepatobiliary surgery—Valuation of early adopters from Germany. Innov. Surg. Sci. 2021, 6, 59–66. [Google Scholar] [CrossRef]
  27. Peyrat, P.; Blanc, E.; Guillermet, S.; Chen, Y.; Ferlay, C.; Perol, D.; Basso, V.; Rivoire, M.; Dupré, A. HEPATOFLUO: A prospective monocentric study assessing the benefits of indocyanine green (ICG) fluorescence for hepatic surgery. J. Surg. Oncol. 2018, 117, 922–927. [Google Scholar] [CrossRef]
  28. Abo, T.; Nanashima, A.; Tobinaga, S.; Hidaka, S.; Taura, N.; Takagi, K.; Arai, J.; Miyaaki, H.; Shibata, H.; Nagayasu, T. Usefulness of intraoperative diagnosis of hepatic tumors located at the liver surface and hepatic segmental visualization using indocyanine green-photodynamic eye imaging. Eur. J. Surg. Oncol. 2015, 41, 257–264. [Google Scholar] [CrossRef]
  29. Marte, G.; Scuderi, V.; Rocca, A.; Surfaro, G.; Migliaccio, C.; Ceriello, A. Laparoscopic splenectomy: A single center experience. Unusual cases and expanded inclusion criteria for laparoscopic approach. Updates Surg. 2013, 65, 115–119. [Google Scholar] [CrossRef]
  30. Rocca, A.; Calise, F.; Marino, G.; Montagnani, S.; Cinelli, M.; Amato, B.; Guerra, G. Primary giant hepatic neuroendocrine carcinoma: A case report. Int. J. Surg. 2014, 12 (Suppl. S1), S218–S221. [Google Scholar] [CrossRef]
  31. Nanashima, A.; Tominaga, T.; Sumida, Y.; Tobinaga, S.; Nagayasu, T. Indocyanine green identification for tumor infiltration or metastasis originating from hepatocellular carcinoma. Int. J. Surg. Case Rep. 2018, 46, 56–61. [Google Scholar] [CrossRef] [PubMed]
  32. Møller, S.; la Cour Sibbesen, E.; Madsen, J.L.; Bendtsen, F. Indocyanine green retention test in cirrhosis and portal hypertension: Accuracy and relation to severity of disease. J. Gastroenterol. Hepatol. 2019, 34, 1093–1099. [Google Scholar] [CrossRef] [PubMed]
  33. Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. Int. J. Surg. 2021, 88, 105906. [Google Scholar] [CrossRef] [PubMed]
  34. Shea, B.J.; Grimshaw, J.M.; Wells, G.A.; Boers, M.; Andersson, N.; Hamel, C.; Porter, A.C.; Tugwell, P.; Moher, D.; Bouter, L.M. Development of AMSTAR: A measurement tool to assess the methodological quality of systematic reviews. BMC Med. Res. Methodol. 2007, 7, 10. [Google Scholar] [CrossRef]
  35. Ouzzani, M.; Hammady, H.; Fedorowicz, Z.; Elmagarmid, A. Rayyan-a web and mobile app for systematic reviews. Syst. Rev. 2016, 5, 210. [Google Scholar] [CrossRef]
  36. Bramer, W.M.; Giustini, D.; de Jonge, G.B.; Holland, L.; Bekhuis, T. De-duplication of database search results for systematic reviews in EndNote. J. Med. Libr. Assoc. 2016, 104, 240–243. [Google Scholar] [CrossRef]
  37. Rocca, A.; Gkaniatsa, E.; Brunese, M.C.; Hessman, E.; Muth, A.; Nwaru, B.I.; Ragnarsson, O.; Bobbio, E.; Esposito, D. Therapeutic outcomes with surgical and medical management for primary aldosteronism: Protocol for a systematic review and meta-analysis. BMJ Open 2023, 13, e072585. [Google Scholar] [CrossRef]
  38. Felli, E.; Ishizawa, T.; Cherkaoui, Z.; Diana, M.; Tripon, S.; Baumert, T.F.; Schuster, C.; Pessaux, P. Laparoscopic anatomical liver resection for malignancies using positive or negative staining technique with intraoperative indocyanine green-fluorescence imaging. HPB 2021, 23, 1647–1655. [Google Scholar] [CrossRef]
  39. Uchiyama, K.; Ueno, M.; Ozawa, S.; Kiriyama, S.; Shigekawa, Y.; Yamaue, H. Combined Use of Contrast-Enhanced Intraoperative Ultrasonography and a Fluorescence Navigation System for Identifying Hepatic Metastases. World J. Surg. 2010, 34, 2953–2959. [Google Scholar] [CrossRef]
  40. Ishizuka, M.; Kubota, K.; Kita, J.; Shimoda, M.; Kato, M.; Sawada, T. Intraoperative observation using a fluorescence imaging instrument during hepatic resection for liver metastasis from colorectal cancer. Hepatogastroenterology 2012, 59, 90–92. [Google Scholar] [CrossRef]
  41. Peloso, A.; Franchi, E.; Canepa, M.C.; Barbieri, L.; Briani, L.; Ferrario, J.; Bianco, C.; Quaretti, P.; Brugnatelli, S.; Dionigi, P.; et al. Combined use of intraoperative ultrasound and indocyanine green fluorescence imaging to detect liver metastases from colorectal cancer. HPB 2013, 15, 928–934. [Google Scholar] [CrossRef] [PubMed]
  42. Satou, S.; Ishizawa, T.; Masuda, K.; Kaneko, J.; Aoki, T.; Sakamoto, Y.; Hasegawa, K.; Sugawara, Y.; Kokudo, N. Indocyanine green fluorescent imaging for detecting extrahepatic metastasis of hepatocellular carcinoma. J. Gastroenterol. 2013, 48, 1136–1143. [Google Scholar] [CrossRef] [PubMed]
  43. Morita, Y.; Sakaguchi, T.; Unno, N.; Shibasaki, Y.; Suzuki, A.; Fukumoto, K.; Inaba, K.; Baba, S.; Takehara, Y.; Suzuki, S.; et al. Detection of hepatocellular carcinomas with near-infrared fluorescence imaging using indocyanine green: Its usefulness and limitation. Int. J. Clin. Oncol. 2013, 18, 232–241. [Google Scholar] [CrossRef] [PubMed]
  44. van der Vorst, J.R.; Schaafsma, B.E.; Hutteman, M.; Verbeek, F.P.; Liefers, G.J.; Hartgrink, H.H.; Smit, V.T.; Löwik, C.W.; van de Velde, C.J.; Frangioni, J.V.; et al. Near-infrared fluorescence-guided resection of colorectal liver metastases. Cancer 2013, 119, 3411–3418. [Google Scholar] [CrossRef]
  45. Kudo, H.; Ishizawa, T.; Tani, K.; Harada, N.; Ichida, A.; Shimizu, A.; Kaneko, J.; Aoki, T.; Sakamoto, Y.; Sugawara, Y.; et al. Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy. Surg. Endosc. 2014, 28, 2504–2508. [Google Scholar] [CrossRef]
  46. Tanaka, T.; Takatsuki, M.; Hidaka, M.; Hara, T.; Muraoka, I.; Soyama, A.; Adachi, T.; Kuroki, T.; Eguchi, S. Is a fluorescence navigation system with indocyanine green effective enough to detect liver malignancies? J. Hepatobiliary Pancreat. Sci. 2014, 21, 199–204. [Google Scholar] [CrossRef]
  47. Tummers, Q.R.; Verbeek, F.P.; Prevoo, H.A.; Braat, A.E.; Baeten, C.I.; Frangioni, J.V.; van de Velde, C.J.; Vahrmeijer, A.L. First experience on laparoscopic near-infrared fluorescence imaging of hepatic uveal melanoma metastases using indocyanine green. Surg. Innov. 2015, 22, 20–25. [Google Scholar] [CrossRef]
  48. Kawaguchi, Y.; Nagai, M.; Nomura, Y.; Kokudo, N.; Tanaka, N. Usefulness of indocyanine green-fluorescence imaging during laparoscopic hepatectomy to visualize subcapsular hard-to-identify hepatic malignancy. J. Surg. Oncol. 2015, 112, 514–516. [Google Scholar] [CrossRef]
  49. Shimada, S.; Ohtsubo, S.; Ogasawara, K.; Kusano, M. Macro- and microscopic findings of ICG fluorescence in liver tumors. World J. Surg. Oncol. 2015, 13, 198. [Google Scholar] [CrossRef]
  50. Takahashi, H.; Zaidi, N.; Berber, E. An initial report on the intraoperative use of indocyanine green fluorescence imaging in the surgical management of liver tumorss. J. Surg. Oncol. 2016, 114, 625–629. [Google Scholar] [CrossRef]
  51. Kaibori, M.; Matsui, K.; Ishizaki, M.; Iida, H.; Okumura, T.; Sakaguchi, T.; Inoue, K.; Ikeura, T.; Asano, H.; Kon, M. Intraoperative Detection of Superficial Liver Tumors by Fluorescence Imaging Using Indocyanine Green and 5-aminolevulinic Acid. Anticancer Res. 2016, 36, 1841–1849. [Google Scholar] [PubMed]
  52. Boogerd, L.S.; Handgraaf, H.J.; Lam, H.D.; Huurman, V.A.; Farina-Sarasqueta, A.; Frangioni, J.V.; van de Velde, C.J.; Braat, A.E.; Vahrmeijer, A.L. Laparoscopic detection and resection of occult liver tumors of multiple cancer types using real-time near-infrared fluorescence guidance. Surg. Endosc. 2017, 31, 952–961. [Google Scholar] [CrossRef] [PubMed]
  53. Barabino, G.; Porcheron, J.; Cottier, M.; Cuilleron, M.; Coutard, J.G.; Berger, M.; Molliex, S.; Beauchesne, B.; Phelip, J.M.; Grichine, A.; et al. Improving Surgical Resection of Metastatic Liver Tumors With Near-Infrared Optical-Guided Fluorescence Imaging. Surg. Innov. 2016, 23, 354–359. [Google Scholar] [CrossRef] [PubMed]
  54. Kaibori, M.; Matsui, K.; Ishizaki, M.; Iida, H.; Sakaguchi, T.; Tsuda, T.; Okumura, T.; Inoue, K.; Shimada, S.; Ohtsubo, S.; et al. Evaluation of fluorescence imaging with indocyanine green in hepatocellular carcinoma. Cancer Imaging 2016, 16, 6. [Google Scholar] [CrossRef]
  55. Handgraaf, H.J.M.; Boogerd, L.S.F.; Höppener, D.J.; Peloso, A.; Sibinga Mulder, B.G.; Hoogstins, C.E.S.; Hartgrink, H.H.; van de Velde, C.J.H.; Mieog, J.S.D.; Swijnenburg, R.J.; et al. Long-term follow-up after near-infrared fluorescence-guided resection of colorectal liver metastases: A retrospective multicenter analysis. Eur. J. Surg. Oncol. 2017, 43, 1463–1471. [Google Scholar] [CrossRef]
  56. Masuda, K.; Kaneko, J.; Kawaguchi, Y.; Togashi, J.; Arita, J.; Akamatsu, N.; Sakamoto, Y.; Hasegawa, K.; Sumihito, T.; Kokudo, N. Diagnostic accuracy of indocyanine green fluorescence imaging and multidetector row computed tomography for identifying hepatocellular carcinoma with liver explant correlation. Hepatol. Res. 2017, 47, 1299–1307. [Google Scholar] [CrossRef]
  57. Benedicenti, S.; Molfino, S.; Alfano, M.S.; Molteni, B.; Porsio, P.; Portolani, N.; Baiocchi, G.L. Indocyanine-Green Fluorescence-GUIDED Liver Resection of Metastasis from Squamous Cell Carcinoma Invading the Biliary Tree. Case Rep. Gastrointest. Med. 2018, 2018, 5849816. [Google Scholar] [CrossRef]
  58. Lieto, E.; Galizia, G.; Cardella, F.; Mabilia, A.; Basile, N.; Castellano, P.; Orditura, M.; Auricchio, A. Indocyanine Green Fluorescence Imaging-Guided Surgery in Primary and Metastatic Liver Tumors. Surg. Innov. 2018, 25, 62–68. [Google Scholar] [CrossRef]
  59. Aoki, T.; Murakami, M.; Koizumi, T.; Matsuda, K.; Fujimori, A.; Kusano, T.; Enami, Y.; Goto, S.; Watanabe, M.; Otsuka, K. Determination of the surgical margin in laparoscopic liver resections using infrared indocyanine green fluorescence. Langenbecks Arch. Surg. 2018, 403, 671–680. [Google Scholar] [CrossRef]
  60. Yoshioka, M.; Taniai, N.; Kawano, Y.; Shimizu, T.; Kondo, R.; Kaneya, Y.; Aoki, Y.; Yoshida, H. Laparoscopic Repeat Hepatectomy with Indocyanine Green Fluorescence Navigation: A Case Report. J. Nippon. Med. Sch. 2019, 86, 291–295. [Google Scholar] [CrossRef]
  61. Alfano, M.S.; Molfino, S.; Benedicenti, S.; Molteni, B.; Porsio, P.; Arici, E.; Gheza, F.; Botticini, M.; Portolani, N.; Baiocchi, G.L. Intraoperative ICG-based imaging of liver neoplasms: A simple yet powerful tool. Preliminary results. Surg. Endosc. 2019, 33, 126–134. [Google Scholar] [CrossRef] [PubMed]
  62. Souzaki, R.; Kawakubo, N.; Matsuura, T.; Yoshimaru, K.; Koga, Y.; Takemoto, J.; Shibui, Y.; Kohashi, K.; Hayashida, M.; Oda, Y.; et al. Navigation surgery using indocyanine green fluorescent imaging for hepatoblastoma patients. Pediatr. Surg. Int. 2019, 35, 551–557. [Google Scholar] [CrossRef]
  63. He, P.; Huang, T.; Fang, C.; Su, S.; Tian, J.; Xia, X.; Li, B. Identification of extrahepatic metastasis of hepatocellular carcinoma using indocyanine green fluorescence imaging. Photodiagnosis Photodyn. Ther. 2019, 25, 417–420. [Google Scholar] [CrossRef] [PubMed]
  64. Shirakawa, S.; Toyama, H.; Kido, M.; Fukumoto, T. A prospective single-center protocol for using near-infrared fluorescence imaging with indocyanine green during staging laparoscopy to detect small metastasis from pancreatic cancer. BMC Surg. 2019, 19, 165. [Google Scholar] [CrossRef] [PubMed]
  65. Li, C.G.; Zhou, Z.P.; Tan, X.L.; Wang, Z.Z.; Liu, Q.; Zhao, Z.M. Robotic resection of liver focal nodal hyperplasia guided by indocyanine green fluorescence imaging: A preliminary analysis of 23 cases. World J. Gastrointest. Oncol. 2020, 12, 1407–1415. [Google Scholar] [CrossRef]
  66. Achterberg, F.B.; Sibinga Mulder, B.G.; Meijer, R.P.J.; Bonsing, B.A.; Hartgrink, H.H.; Mieog, J.S.D.; Zlitni, A.; Park, S.M.; Farina Sarasqueta, A.; Vahrmeijer, A.L.; et al. Real-time surgical margin assessment using ICG-fluorescence during laparoscopic and robot-assisted resections of colorectal liver metastases. Ann. Transl. Med. 2020, 8, 1448. [Google Scholar] [CrossRef]
  67. Li, B.; Liu, T.; Zhang, Y.; Zhang, J. Retroperitoneal laparoscopic hepatectomy of recurrent hepatocellular carcinoma: Case report and literature review. BMC Gastroenterol. 2020, 20, 278. [Google Scholar] [CrossRef]
  68. Tashiro, Y.; Aoki, T.; Hirai, T.; Koizumi, T.; Mansou, D.A.; Kusano, T.; Matsuda, K.; Yamada, K.; Nogaki, K.; Hakozaki, T.; et al. Pathological Validity of Using Near-infrared Fluorescence Imaging for Securing Surgical Margins During Liver Resection. Anticancer. Res. 2020, 40, 3873–3882. [Google Scholar] [CrossRef]
  69. He, K.; Hong, X.; Chi, C.; Cai, C.; Wang, K.; Li, P.; Liu, X.; Li, J.; Shan, H.; Tian, J. A new method of near-infrared fluorescence image-guided hepatectomy for patients with hepatolithiasis: A randomized controlled trial. Surg. Endosc. 2020, 34, 4975–4982. [Google Scholar] [CrossRef]
  70. Mehdorn, A.S.; Beckmann, J.H.; Braun, F.; Becker, T.; Egberts, J.H. Usability of Indocyanine Green in Robot-Assisted Hepatic Surgery. J. Clin. Med. 2021, 10, 456. [Google Scholar] [CrossRef]
  71. Matsumura, M.; Seyama, Y.; Ishida, H.; Nemoto, S.; Tani, K.; Imamura, J. Indocyanine green fluorescence navigation for hepatocellular carcinoma with bile duct tumor thrombus: A case report. Surg. Case Rep. 2021, 7, 18. [Google Scholar] [CrossRef]
  72. Bijlstra, O.D.; Achterberg, F.B.; Tummers, Q.; Mieog, J.S.D.; Hartgrink, H.H.; Vahrmeijer, A.L. Near-infrared fluorescence-guided metastasectomy for hepatic gastrointestinal stromal tumor metastases using indocyanine green: A case report. Int. J. Surg. Case Rep. 2021, 78, 250–253. [Google Scholar] [CrossRef] [PubMed]
  73. Kobayashi, K.; Kawaguchi, Y.; Kobayashi, Y.; Matsumura, M.; Ishizawa, T.; Akamatsu, N.; Kaneko, J.; Arita, J.; Sakamoto, Y.; Kokudo, N.; et al. Identification of liver lesions using fluorescence imaging: Comparison of methods for administering indocyanine green. HPB 2021, 23, 262–269. [Google Scholar] [CrossRef] [PubMed]
  74. Cho, Y.J.; Namgoong, J.M.; Kwon, H.H.; Kwon, Y.J.; Kim, D.Y.; Kim, S.C. The Advantages of Indocyanine Green Fluorescence Imaging in Detecting and Treating Pediatric Hepatoblastoma: A Preliminary Experience. Front. Pediatr. 2021, 9, 635394. [Google Scholar] [CrossRef] [PubMed]
  75. Han, H.W.; Shi, N.; Zou, Y.P.; Zhang, Y.P.; Lin, Y.; Yin, Z.; Jian, Z.X.; Jin, H.S. Functional anatomical hepatectomy guided by indocyanine green fluorescence imaging in patients with localized cholestasis: Report of four cases. World J. Gastrointest. Surg. 2021, 13, 323–329. [Google Scholar] [CrossRef]
  76. Whitlock, R.S.; Patel, K.R.; Yang, T.; Nguyen, H.N.; Masand, P.; Vasudevan, S.A. Pathologic correlation with near infrared-indocyanine green guided surgery for pediatric liver cancer. J. Pediatr. Surg. 2022, 57, 700–710. [Google Scholar] [CrossRef]
  77. Lake, C.M.; Bondoc, A.J.; Dasgupta, R.; Jenkins, T.M.; Towbin, A.J.; Smith, E.A.; Alonso, M.H.; Geller, J.I.; Tiao, G.M. Indocyanine green is a sensitive adjunct in the identification and surgical management of local and metastatic hepatoblastoma. Cancer Med. 2021, 10, 4322–4343. [Google Scholar] [CrossRef]
  78. Gerber, D.A.; Vonderau, J.S.; Iwai, Y.; Steele, P.; Serrano, P.; Desai, C.S. Indocyanine Green as a Navigational Adjunct for Laparoscopic Ablation of Liver Tumors. Am. Surg. 2023, 89, 4801–4805. [Google Scholar] [CrossRef]
  79. Seo, S.; Ogiso, S.; Toda, R.; Nishino, H.; Fukumitsu, K.; Ishii, T.; Yoshizawa, A.; Taura, K.; Hatano, E. Intraoperative indocyanine green imaging facilitates optimal surgical margin for colorectal liver metastasis with preoperatively undetected intrabiliary tumor growth. J. Hepatobiliary Pancreat. Sci. 2022, 29, e48–e49. [Google Scholar] [CrossRef]
  80. Feng, J.; Qin, H.; Yang, W.; Cheng, H.; Xu, J.; Han, J.; Mou, J.; Wang, H.; Ni, X. Tumor-Background Ratio is an effective method to identify tumors and false-positive nodules in indocyanine-green navigation surgery for pediatric liver cancer. Front. Pediatr. 2022, 10, 875688. [Google Scholar] [CrossRef]
  81. Shen, Y.; Zheng, M.; Li, J.; Tan, T.; Yang, J.; Pan, J.; Hu, C.; Zou, Y.; Yang, T. Clinical Application of Indocyanine Green Fluorescence Imaging in the Resection of Hepatoblastoma: A Single Institution’s Experiences. Front. Surg. 2022, 9, 932721. [Google Scholar] [CrossRef]
  82. Hu, Y.; Guo, W.; Ma, J.; Yu, J.; Liu, W.; Zhang, C.; Jia, W.; Ge, Y. Application of Indocyanine Green Fluorescence Imaging Combined with Laparoscopic Ultrasound in Laparoscopic Microwave Ablation of Liver Cancer. Med. Sci. Monit. 2022, 28, e937832. [Google Scholar] [CrossRef]
  83. Wang, G.; Luo, Y.; Qi, W.; Yuan, C.; Xiu, D. Determination of surgical margins in laparoscopic parenchyma-sparing hepatectomy of neuroendocrine tumors liver metastases using indocyanine green fluorescence imaging. Surg. Endosc. 2022, 36, 4408–4416. [Google Scholar] [CrossRef]
  84. Itoh, S.; Tomiyama, T.; Morinaga, A.; Kurihara, T.; Nagao, Y.; Toshima, T.; Morita, K.; Harada, N.; Mori, M.; Yoshizumi, T. Clinical effects of the use of the indocyanine green fluorescence imaging technique in laparoscopic partial liver resection. Ann. Gastroenterol. Surg. 2022, 6, 688–694. [Google Scholar] [CrossRef] [PubMed]
  85. Peng, Y.; Tan, S.; Zhu, G.; Fang, C.; He, P.; Peng, F.; Gan, Y.; Tian, J.; Su, S.; Yang, X.; et al. Successful application of ICG fluorescence imaging technology in rectal neuroendocrine tumor liver metastasis. Photodiagn. Photodyn. Ther. 2022, 37, 102653. [Google Scholar] [CrossRef] [PubMed]
  86. Rompianesi, G.; Pegoraro, F.; Ramaci, L.; Ceresa, C.D.; Montalti, R.; Troisi, R.I. Preoperative planning and intraoperative real-time navigation with indocyanine green fluorescence in robotic liver surgery. Langenbecks Arch. Surg. 2023, 408, 292. [Google Scholar] [CrossRef] [PubMed]
  87. Shen, Q.; Liu, X.; Pan, S.; Li, T.; Zhou, J. Effectiveness of indocyanine green fluorescence imaging in resection of hepatoblastoma. Pediatr. Surg. Int. 2023, 39, 181. [Google Scholar] [CrossRef]
  88. Sebagh, M.; Desterke, C.; Feray, C.; Hamelin, J.; Habib, M.; Samuel, D.; Rosmorduc, O.; Vibert, E.; Golse, N. Indocyanine green fluorescence patterns of hepatocellular carcinoma correlate with pathological and molecular features. HPB 2023, 25, 198–209. [Google Scholar] [CrossRef]
  89. Liu, S.; Feng, J.; Ren, Q.; Qin, H.; Yang, W.; Cheng, H.; Yao, X.; Xu, J.; Han, J.; Chang, S.; et al. Evaluating the clinical efficacy and limitations of indocyanine green fluorescence-guided surgery in childhood hepatoblastoma: A retrospective study. Photodiagn. Photodyn. Ther. 2023, 44, 103790. [Google Scholar] [CrossRef]
  90. Aoki, T.; Murakami, M.; Yasuda, D.; Shimizu, Y.; Kusano, T.; Matsuda, K.; Niiya, T.; Kato, H.; Murai, N.; Otsuka, K.; et al. Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography. J. Hepatobiliary Pancreat. Sci. 2010, 17, 590–594. [Google Scholar] [CrossRef]
  91. Uchiyama, K.; Ueno, M.; Ozawa, S.; Kiriyama, S.; Shigekawa, Y.; Hirono, S.; Kawai, M.; Tani, M.; Yamaue, H. Combined intraoperative use of contrast-enhanced ultrasonography imaging using a sonazoid and fluorescence navigation system with indocyanine green during anatomical hepatectomy. Langenbecks Arch. Surg. 2011, 396, 1101–1107. [Google Scholar] [CrossRef]
  92. Ishizawa, T.; Zuker, N.B.; Kokudo, N.; Gayet, B. Positive and negative staining of hepatic segments by use of fluorescent imaging techniques during laparoscopic hepatectomy. Arch. Surg. 2012, 147, 393–394. [Google Scholar] [CrossRef] [PubMed]
  93. Sakoda, M.; Ueno, S.; Iino, S.; Hiwatashi, K.; Minami, K.; Kawasaki, Y.; Kurahara, H.; Mataki, Y.; Maemura, K.; Uenosono, Y.; et al. Anatomical laparoscopic hepatectomy for hepatocellular carcinoma using indocyanine green fluorescence imaging. J. Laparoendosc. Adv. Surg. Tech. A 2014, 24, 878–882. [Google Scholar] [CrossRef]
  94. Kurihara, T.; Yamashita, Y.; Yoshida, Y.; Takeishi, K.; Itoh, S.; Harimoto, N.; Yoshizumi, T.; Shirabe, K.; Ikeda, T.; Maehara, Y. Indocyanine Green Fluorescent Imaging for Hepatic Resection of the Right Hepatic Vein Drainage Area. J. Am. Coll. Surg. 2015, 221, e49–e53. [Google Scholar] [CrossRef] [PubMed]
  95. Inoue, Y.; Saiura, A.; Arita, J.; Takahashi, Y. Hepatic Vein-Oriented Liver Resection Using Fusion Indocyanine Green Fluorescence Imaging. Ann. Surg. 2015, 262, e98–e99. [Google Scholar] [CrossRef]
  96. Miyata, A.; Ishizawa, T.; Tani, K.; Shimizu, A.; Kaneko, J.; Aoki, T.; Sakamoto, Y.; Sugawara, Y.; Hasegawa, K.; Kokudo, N. Reappraisal of a Dye-Staining Technique for Anatomic Hepatectomy by the Concomitant Use of Indocyanine Green Fluorescence Imaging. J. Am. Coll. Surg. 2015, 221, e27–e36. [Google Scholar] [CrossRef]
  97. Inoue, Y.; Arita, J.; Sakamoto, T.; Ono, Y.; Takahashi, M.; Takahashi, Y.; Kokudo, N.; Saiura, A. Anatomical Liver Resections Guided by 3-Dimensional Parenchymal Staining Using Fusion Indocyanine Green Fluorescence Imaging. Ann. Surg. 2015, 262, 105–111. [Google Scholar] [CrossRef] [PubMed]
  98. Kobayashi, Y.; Kawaguchi, Y.; Kobayashi, K.; Mori, K.; Arita, J.; Sakamoto, Y.; Hasegawa, K.; Kokudo, N. Portal vein territory identification using indocyanine green fluorescence imaging: Technical details and short-term outcomes. J. Surg. Oncol. 2017, 116, 921–931. [Google Scholar] [CrossRef]
  99. Kawaguchi, Y.; Nomura, Y.; Nagai, M.; Koike, D.; Sakuraoka, Y.; Ishida, T.; Ishizawa, T.; Kokudo, N.; Tanaka, N. Liver transection using indocyanine green fluorescence imaging and hepatic vein clamping. Br. J. Surg. 2017, 104, 898–906. [Google Scholar] [CrossRef]
  100. Meng, X.; Wang, H.; Xu, Y.; Chen, M.; Duan, W.; Lu, S. Indocyanine green fluorescence image-guided total laparoscopic living donor right hepatectomy: The first case report from Mainland China. Int. J. Surg. Case Rep. 2018, 53, 406–409. [Google Scholar] [CrossRef]
  101. Nomi, T.; Hokuto, D.; Yoshikawa, T.; Matsuo, Y.; Sho, M. A Novel Navigation for Laparoscopic Anatomic Liver Resection Using Indocyanine Green Fluorescence. Ann. Surg. Oncol. 2018, 25, 3982. [Google Scholar] [CrossRef] [PubMed]
  102. Nishino, H.; Hatano, E.; Seo, S.; Nitta, T.; Saito, T.; Nakamura, M.; Hattori, K.; Takatani, M.; Fuji, H.; Taura, K.; et al. Real-time Navigation for Liver Surgery Using Projection Mapping With Indocyanine Green Fluorescence: Development of the Novel Medical Imaging Projection System. Ann. Surg. 2018, 267, 1134–1140. [Google Scholar] [CrossRef]
  103. Yang, J.; Tao, H.S.; Cai, W.; Zhu, W.; Zhao, D.; Hu, H.Y.; Liu, J.; Fang, C.H. Accuracy of actual resected liver volume in anatomical liver resections guided by 3-dimensional parenchymal staining using fusion indocyanine green fluorescence imaging. J. Surg. Oncol. 2018, 118, 1081–1087. [Google Scholar] [CrossRef] [PubMed]
  104. Ueno, M.; Hayami, S.; Sonomura, T.; Tanaka, R.; Kawai, M.; Hirono, S.; Okada, K.I.; Yamaue, H. Indocyanine green fluorescence imaging techniques and interventional radiology during laparoscopic anatomical liver resection (with video). Surg. Endosc. 2018, 32, 1051–1055. [Google Scholar] [CrossRef]
  105. Chiba, N.; Shimazu, M.; Ochiai, S.; Yokozuka, K.; Gunji, T.; Okihara, M.; Sano, T.; Tomita, K.; Tsutsui, R.; Oshima, G.; et al. Resection of Hepatic Lesions Perfused by the Cholecystic Vein Using Indocyanine Green Navigation in Patients with cT2 Gallbladder Cancer. World J. Surg. 2019, 43, 608–614. [Google Scholar] [CrossRef] [PubMed]
  106. Ueno, M.; Hayami, S.; Sonomura, T.; Kawai, M.; Hirono, S.; Okada, K.I.; Tanaka, R.; Yamaue, H. Concomitant Use of Indocyanine Green Fluorescence Imaging and Interventional Radiology for Detection of Liver Segments During Laparoscopic Anatomical Liver Resection: Pilot Feasibility Study. Surg. Laparosc. Endosc. Percutan Tech. 2019, 29, 242–246. [Google Scholar] [CrossRef]
  107. Nanashima, A.; Yano, K.; Tobinaga, S. Efficacy of Hepatic Segmental Visualization Using Indocyanine Green Photodynamic Eye Imaging. World J. Surg. 2019, 43, 1308–1312. [Google Scholar] [CrossRef]
  108. Xu, Y.; Chen, M.; Meng, X.; Lu, P.; Wang, X.; Zhang, W.; Luo, Y.; Duan, W.; Lu, S.; Wang, H. Laparoscopic anatomical liver resection guided by real-time indocyanine green fluorescence imaging: Experience and lessons learned from the initial series in a single center. Surg. Endosc. 2020, 34, 4683–4691. [Google Scholar] [CrossRef]
  109. Kubo, N.; Araki, K.; Harimoto, N.; Ishii, N.; Tsukagoshi, M.; Igarashi, T.; Watanabe, A.; Shirabe, K. Hepatic resection for the right hepatic vein drainage area with indocyanine green fluorescent imaging navigation. J. Hepatobiliary Pancreat. Sci. 2020, 27, 371–379. [Google Scholar] [CrossRef]
  110. Ito, D.; Ishizawa, T.; Hasegawa, K. Laparoscopic positive staining of hepatic segments using indocyanine green-fluorescence imaging. J. Hepatobiliary Pancreat. Sci. 2020, 27, 441–443. [Google Scholar] [CrossRef]
  111. Pansa, A.; Torzilli, G.; Procopio, F.; Del Fabbro, D. Indocyanine-green fluorescence guided anatomical segmentectomy for HCC with portal thrombosis: The counter-fluorescence technique. Updates Surg. 2020, 72, 219–222. [Google Scholar] [CrossRef] [PubMed]
  112. Urade, T.; Sawa, H.; Iwatani, Y.; Abe, T.; Fujinaka, R.; Murata, K.; Mii, Y.; Man, I.M.; Oka, S.; Kuroda, D. Laparoscopic anatomical liver resection using indocyanine green fluorescence imaging. Asian J. Surg. 2020, 43, 362–368. [Google Scholar] [CrossRef]
  113. Aoki, T.; Koizumi, T.; Mansour, D.A.; Fujimori, A.; Kusano, T.; Matsuda, K.; Tashiro, Y.; Watanabe, M.; Otsuka, K.; Murakami, M. Ultrasound-Guided Preoperative Positive Percutaneous Indocyanine Green Fluorescence Staining for Laparoscopic Anatomical Liver Resection. J. Am. Coll. Surg. 2020, 230, e7–e12. [Google Scholar] [CrossRef] [PubMed]
  114. Zhai, S.T.; Liang, X.; Mao, Q.J.; Liang, Y.L.; Xu, J.J.; Chen, J.; Shi, L.; Xie, Y.Y.; Cai, X.J. A retrospective pilot study to examine the feasibility of real-time navigation for laparoscopic liver resections in intrahepatic cholangiocarcinoma using fusion indocyanine green fluorescence imaging. J. Surg. Oncol. 2020, 122, 226–233. [Google Scholar] [CrossRef] [PubMed]
  115. Berardi, G.; Igarashi, K.; Li, C.J.; Ozaki, T.; Mishima, K.; Nakajima, K.; Honda, M.; Wakabayashi, G. Parenchymal Sparing Anatomical Liver Resections With Full Laparoscopic Approach: Description of Technique and Short-term Results. Ann. Surg. 2021, 273, 785–791. [Google Scholar] [CrossRef]
  116. Procopio, F.; Torzilli, G.; Franchi, E.; Cimino, M.; Viganò, L.; Donadon, M.; Del Fabbro, D. Ultrasound-guided anatomical liver resection using a compression technique combined with indocyanine green fluorescence imaging. HPB 2021, 23, 206–211. [Google Scholar] [CrossRef]
  117. Funamizu, N.; Ozaki, T.; Mishima, K.; Igarashi, K.; Omura, K.; Takada, Y.; Wakabayashi, G. Evaluation of accuracy of laparoscopic liver mono-segmentectomy using the Glissonian approach with indocyanine green fluorescence negative staining by comparing estimated and actual resection volumes: A single-center retrospective cohort study. J. Hepatobiliary Pancreat. Sci. 2021, 28, 1060–1068. [Google Scholar] [CrossRef]
  118. Yasuda, J.; Haruki, K.; Furukawa, K.; Onda, S.; Shirai, Y.; Gocho, T.; Ikegami, T. Double cone-unit laparoscopic hepatic resection using indocyanine green negative counterstaining (with video). Surg. Today 2021, 51, 1881–1885. [Google Scholar] [CrossRef]
  119. Li, W.F.; Al-Taher, M.; Yu, C.Y.; Liu, Y.W.; Liu, Y.Y.; Marescaux, J.; Cheng, Y.F.; Diana, M.; Wang, C.C. Super-Selective Intra-Arterial Indocyanine Green Administration for Near-Infrared Fluorescence-Based Positive Staining of Hepatic Segmentation: A Feasibility Study. Surg. Innov. 2021, 28, 669–678. [Google Scholar] [CrossRef]
  120. Liang, X.; Zheng, J.; Xu, J.; Tao, L.; Cai, J.; Liang, Y.; Feng, X.; Cai, X. Laparoscopic anatomical portal territory hepatectomy using Glissonean pedicle approach (Takasaki approach) with indocyanine green fluorescence negative staining: How I do it. HPB 2021, 23, 1392–1399. [Google Scholar] [CrossRef]
  121. Ceccarelli, G.; Codacci-Pisanelli, M.; De Rosa, M.; Mariani, L.; Rocca, A.; Mazzucca, D.; Polistena, A. Robot-Assisted Liver Resection and Cholecystectomy Using Indocyanine-Green for Intrahepatic Cholangiocarcinoma, in a Very Rare Anatomical Anomaly of ‘Bipartite Liver’. Surg. Innov. 2022, 29, 488–493. [Google Scholar] [CrossRef] [PubMed]
  122. Kasai, M.; Aihara, T.; Ikuta, S.; Nakajima, T.; Yamanaka, N. A Percutaneous Portal Vein Puncture Under Artificial Ascites for Intraoperative Hepatic Segmentation Using Indocyanine Green Fluorescence: A Technical Report of Laparoscopic Anatomic Liver Resection. Surg. Laparosc. Endosc. Percutan Tech. 2021, 32, 281–284. [Google Scholar] [CrossRef] [PubMed]
  123. Chen, R.; Wang, Z.; Zhu, W.; Luo, W.; Lin, J.; Chen, Y.; Fang, C.; Yang, J. Laparoscopic in Situ Anatomical Mesohepatectomy for Solitary Massive HCC Using Combined Intrafascial and Extrafascial Approaches With Indocyanine Green Navigation (with Video). Ann. Surg. Oncol. 2022, 29, 2034–2040. [Google Scholar] [CrossRef] [PubMed]
  124. Lan, X.; Tang, Y.; Wei, W.; Jiang, K.; Chen, K.; Du, C.; Hao, X.; Liu, H. Indocyanine green fluorescence staining based on the “hepatic pedicle first” approach during laparoscopic anatomic liver resection. Surg. Endosc. 2022, 36, 8121–8131. [Google Scholar] [CrossRef]
  125. Zhang, Y.; Zhu, J.; Tao, H.; Liang, H.; Chen, Y.; Zhang, Z.; Zhao, J.; Zhang, W. Clinical application of indocyanine green fluorescence imaging in laparoscopic lymph node dissection for intrahepatic cholangiocarcinoma: A pilot study (with video). Surgery 2022, 171, 1589–1595. [Google Scholar] [CrossRef]
  126. Cheng, J.; Wang, Z.; Liu, J.; Dou, C.; Yao, W.; Zhang, C. Value of 3D printing technology combined with indocyanine green fluorescent navigation in complex laparoscopic hepatectomy. PLoS ONE 2022, 17, e0272815. [Google Scholar] [CrossRef]
  127. Zhou, Y.; Zhang, C.; Wang, Y.; Yu, J.; Wang, D.; Ma, J. Effects of indocyanine green fluorescence imaging of laparoscopic anatomic liver resection for HCC: A propensity score-matched study. Langenbecks Arch. Surg. 2023, 408, 51. [Google Scholar] [CrossRef]
  128. Sun, J.; Lu, Z.Y.; Zhai, J.X.; Lang, M.R.; Wang, H.G. Laparoscopic Anatomical Liver Resection of Segment VIII by Using ICG Fluorescence Positive Staining Under the Guidance of Laparoscopic Ultrasonography. Ann. Surg. Oncol. 2023, 30, 7358–7359. [Google Scholar] [CrossRef]
  129. Luján, J.; Almeida, A.; López-Olaondo, L.; Rotellar, F. Laparoscopic radical hepatectomy and lymphadenectomy for incidental gallbladder cancer. Surgical technique with ICG fluorescence enhancement. Surg. Oncol. 2022, 42, 101756. [Google Scholar] [CrossRef]
  130. Wan, H.; Xie, K.; Wu, H. Parenchymal Sparing Laparoscopic Segmentectomy III and IV with Indocyanine Green Fluorescence Negative Stain Method Using Glisson Pedicle Approach. J. Gastrointest. Surg. 2023, 27, 203–204. [Google Scholar] [CrossRef]
  131. Jiang, Z.; Zhou, B.; Zheng, X.; Li, G.; Gao, Z.; Tian, Y.; Shao, C.; Xu, S.; Yan, S. A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII. Front. Oncol. 2023, 13, 1138068. [Google Scholar] [CrossRef] [PubMed]
  132. Lin, W.; Li, X.; Wang, Z.; Tao, H.; Fang, C.; Yang, J. Indocyanine green fluorescence image-guided laparoscopic anatomical S2/3 resection using the TICGL technique. Surg. Endosc. 2024, 38, 1069–1076. [Google Scholar] [CrossRef]
  133. Terasawa, M.; Ishizawa, T.; Mise, Y.; Inoue, Y.; Ito, H.; Takahashi, Y.; Saiura, A. Applications of fusion-fluorescence imaging using indocyanine green in laparoscopic hepatectomy. Surg. Endosc. 2017, 31, 5111–5118. [Google Scholar] [CrossRef] [PubMed]
  134. Zhang, Y.M.; Shi, R.; Hou, J.C.; Liu, Z.R.; Cui, Z.L.; Li, Y.; Wu, D.; Shi, Y.; Shen, Z.Y. Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging. J. Cancer Res. Clin. Oncol. 2017, 143, 51–58. [Google Scholar] [CrossRef]
  135. Cheung, T.T.; Ma, K.W.; She, W.H.; Dai, W.C.; Tsang, S.H.Y.; Chan, A.C.Y.; Chok, K.S.H.; Lo, C.M. Pure laparoscopic hepatectomy with augmented reality-assisted indocyanine green fluorescence versus open hepatectomy for hepatocellular carcinoma with liver cirrhosis: A propensity analysis at a single center. Asian J. Endosc. Surg. 2018, 11, 104–111. [Google Scholar] [CrossRef] [PubMed]
  136. Gon, H.; Komatsu, S.; Murakami, S.; Kido, M.; Tanaka, M.; Kuramitsu, K.; Tsugawa, D.; Awazu, M.; Toyama, H.; Fukumoto, T. Real-time navigation during hepatectomy using fusion indocyanine green-fluorescence imaging: Protocol for a prospective cohort study. BMJ Open 2019, 9, e030233. [Google Scholar] [CrossRef]
  137. Marino, M.V.; Di Saverio, S.; Podda, M.; Gomez Ruiz, M.; Gomez Fleitas, M. The Application of Indocyanine Green Fluorescence Imaging During Robotic Liver Resection: A Case-Matched Study. World J. Surg. 2019, 43, 2595–2606. [Google Scholar] [CrossRef]
  138. Zhou, Y.; Lin, Y.; Jin, H.; Hou, B.; Yu, M.; Yin, Z.; Jian, Z. Real-Time Navigation Guidance Using Fusion Indocyanine Green Fluorescence Imaging in Laparoscopic Non-Anatomical Hepatectomy of Hepatocellular Carcinomas at Segments 6, 7, or 8 (with Videos). Med. Sci. Monit. 2019, 25, 1512–1517. [Google Scholar] [CrossRef]
  139. Lu, H.; Gu, J.; Qian, X.F.; Dai, X.Z. Indocyanine green fluorescence navigation in laparoscopic hepatectomy: A retrospective single-center study of 120 cases. Surg. Today 2021, 51, 695–702. [Google Scholar] [CrossRef]
  140. Li, Y.P.; Ma, Z.G.; Tuxun, T.; Li, Z.D.; Meng, Y.; Chen, X. The application of laparoscopy combined with indocyanine green fluorescence imaging technique for hepatic cystic echinococcosis. BMC Surg. 2020, 20, 249. [Google Scholar] [CrossRef]
  141. Miyashita, S.; Hatano, E.; Tada, M.; Okada, T. Hepatectomy using a novel cart-based indocyanine green fluorescence imaging system. Surg. Today 2020, 50, 1308–1313. [Google Scholar] [CrossRef] [PubMed]
  142. Yao, S.; Zhang, L.; Ma, J.; Jia, W.; Chen, H. Precise right hemihepatectomy for the treatment of hepatocellular carcinoma guided by fusion ICG fluorescence imaging. J. Cancer 2020, 11, 2465–2475. [Google Scholar] [CrossRef] [PubMed]
  143. Zhang, P.; Luo, H.; Zhu, W.; Yang, J.; Zeng, N.; Fan, Y.; Wen, S.; Xiang, N.; Jia, F.; Fang, C. Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging. Surg. Endosc. 2020, 34, 3449–3459. [Google Scholar] [CrossRef] [PubMed]
  144. Marino, M.V.; Podda, M.; Fernandez, C.C.; Ruiz, M.G.; Fleitas, M.G. The application of indocyanine green-fluorescence imaging during robotic-assisted liver resection for malignant tumors: A single-arm feasibility cohort study. HPB 2020, 22, 422–431. [Google Scholar] [CrossRef]
  145. Kose, E.; Kahramangil, B.; Aydin, H.; Donmez, M.; Takahashi, H.; Acevedo-Moreno, L.A.; Sasaki, K.; Aucejo, F.; Berber, E. A comparison of indocyanine green fluorescence and laparoscopic ultrasound for detection of liver tumors. HPB 2020, 22, 764–769. [Google Scholar] [CrossRef]
  146. Zheng, J.H.; Zhai, S.T.; Liang, X. Laparoscopic Portal Territory Hepatectomy (Extended Segment 5) by an Indocyanine Green Fluorescent Dual Staining Technique (Video). J. Gastrointest. Surg. 2021, 25, 329–330. [Google Scholar] [CrossRef]
  147. Li, J.; Li, X.; Zhang, X.; Wang, H.; Li, K.; He, Y.; Liu, Z.; Zhang, Z.; Yuan, Y. Indocyanine green fluorescence imaging-guided laparoscopic right posterior hepatectomy. Surg. Endosc. 2022, 36, 1293–1301. [Google Scholar] [CrossRef]
  148. Qiu, R.; Wu, Y.; Su, J.; Chen, L.; Liao, M.; Zhao, Z.; Lu, Z.; Xiong, X.; Jin, S.; Deng, X. Deploying Indocyanine Green Fluorescence-Guided Navigation System in Precise Laparoscopic Resection of Pediatric Hepatoblastoma. Cancers 2022, 14, 6057. [Google Scholar] [CrossRef]
  149. Liu, F.; Wang, H.; Ma, W.; Li, J.; Liu, Y.; Tang, S.; Li, K.; Jiang, P.; Yang, Z.; He, Y.; et al. Short- and Long-Term Outcomes of Indocyanine Green Fluorescence Navigation- Versus Conventional-Laparoscopic Hepatectomy for Hepatocellular Carcinoma: A Propensity Score-Matched, Retrospective, Cohort Study. Ann. Surg. Oncol. 2023, 30, 1991–2002. [Google Scholar] [CrossRef]
  150. Karmarkar, R.; Benjafield, A.; Aroori, S. The Role of Colour Segmented Fluorescence (CSF) Mode and Same-day Administration of Low-dose Indocyanine Green in Liver Surgery: Our Initial Experience: Indocyanine Green Fluorescence Guided Resection of Liver Tumours. J. Fluoresc. 2023, 34, 2133–2138. [Google Scholar] [CrossRef]
  151. Kasai, M.; Aihara, T.; Ikuta, S.; Nakajima, T.; Yamanaka, N. Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection. Cureus 2023, 15, e46771. [Google Scholar] [CrossRef] [PubMed]
  152. Hardy, N.P.; Epperlein, J.P.; Dalli, J.; Robertson, W.; Liddy, R.; Aird, J.J.; Mulligan, N.; Neary, P.M.; McEntee, G.P.; Conneely, J.B.; et al. Real-time administration of indocyanine green in combination with computer vision and artificial intelligence for the identification and delineation of colorectal liver metastases. Surg. Open Sci. 2023, 12, 48–54. [Google Scholar] [CrossRef] [PubMed]
  153. Alomari, M.A.M.; Wakabayashi, T.; Colella, M.; Mishima, K.; Fujiyama, Y.; Ababneh, E.; Wakabayashi, G. Comparing the accuracy of positive and negative indocyanine green staining in guiding laparoscopic anatomical liver resection: Protocol for a randomised controlled trial. BMJ Open 2023, 13, e072926. [Google Scholar] [CrossRef] [PubMed]
  154. Cai, X.; Hong, H.; Pan, W.; Chen, J.; Jiang, L.; Du, Q.; Li, G.; Lin, S.; Chen, Y. Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study. Ann. Surg. Oncol. 2023, 30, 1981–1987. [Google Scholar] [CrossRef]
  155. Weixler, B.; Lobbes, L.A.; Scheiner, L.; Lauscher, J.C.; Staubli, S.M.; Zuber, M.; Raptis, D.A. The Value of Indocyanine Green Image-Guided Surgery in Patients with Primary Liver Tumors and Liver Metastases. Life 2023, 13, 1290. [Google Scholar] [CrossRef]
  156. Tao, H.; Wang, Z.; Zeng, X.; Hu, H.; Li, J.; Lin, J.; Lin, W.; Fang, C.; Yang, J. Augmented Reality Navigation Plus Indocyanine Green Fluorescence Imaging Can Accurately Guide Laparoscopic Anatomical Segment 8 Resection. Ann. Surg. Oncol. 2023, 30, 7373–7383. [Google Scholar] [CrossRef]
  157. Troisi, R.I.; Elsheikh, Y.M.; Shagrani, M.A.; Broering, D. First fully laparoscopic donor hepatectomy for pediatric liver transplantation using the indocyanine green near-infrared fluorescence imaging in the Middle East: A case report. Ann. Saudi Med. 2014, 34, 354–357. [Google Scholar] [CrossRef]
  158. Tomassini, F.; Scarinci, A.; Elsheik, Y.; Scuderi, V.; Broering, D.; Troisi, R.I. Indocyanine Green Near-Infrared Fluorescence in Pure Laparoscopic Living Donor Hepatectomy: A Reliable Road Map for Intra-Hepatic Ducts? Acta Chir. Belg. 2015, 115, 2–7. [Google Scholar] [CrossRef]
  159. Panaro, F.; Benedetti, E.; Pineton de Chambrun, G.; Habibeh, H.; Leon, P.; Bouyabrine, H.; Herrero, A.; Navarro, F. Indocyanine green fluorescence angiography during liver and pancreas transplantation: A tool to integrate perfusion statement’s evaluation. Hepatobiliary Surg. Nutr. 2018, 7, 161–166. [Google Scholar] [CrossRef]
  160. Kim, J.; Hong, S.K.; Lim, J.; Lee, J.M.; Cho, J.H.; Choi, Y.; Yi, N.J.; Lee, K.W.; Suh, K.S. Demarcating the Exact Midplane of the Liver Using Indocyanine Green Near-Infrared Fluorescence Imaging During Laparoscopic Donor Hepatectomy. Liver Transpl. 2021, 27, 830–839. [Google Scholar] [CrossRef]
  161. Sakaguchi, T.; Suzuki, A.; Unno, N.; Morita, Y.; Oishi, K.; Fukumoto, K.; Inaba, K.; Suzuki, M.; Tanaka, H.; Sagara, D.; et al. Bile leak test by indocyanine green fluorescence images after hepatectomy. Am. J. Surg. 2010, 200, e19–e23. [Google Scholar] [CrossRef] [PubMed]
  162. Kaibori, M.; Ishizaki, M.; Matsui, K.; Kwon, A.H. Intraoperative indocyanine green fluorescent imaging for prevention of bile leakage after hepatic resection. Surgery 2011, 150, 91–98. [Google Scholar] [CrossRef] [PubMed]
  163. Umemura, A.; Nitta, H.; Suto, T.; Fujiwara, H.; Takahara, T.; Hasegawa, Y.; Katagiri, H.; Kanno, S.; Ando, T.; Sasaki, A. Indocyanine green fluorescence imaging via endoscopic nasal biliary drainage during laparoscopic deroofing of liver cysts. J. Minim. Access Surg. 2021, 17, 131–134. [Google Scholar] [CrossRef] [PubMed]
  164. Hanaki, T.; Goto, K.; Tokuyasu, N.; Endo, Y.; Sunada, H.; Noma, H.; Sunaguchi, T.; Murakami, Y.; Matsunaga, T.; Yamamoto, M.; et al. Efficacy of indocyanine green systemic administration for bile leak detection after hepatectomy: A protocol for a prospective single-arm clinical trial with a historical control group. BMJ Open 2023, 13, e068223. [Google Scholar] [CrossRef]
  165. Sasaki, N.; Okamura, Y.; Nishitai, R. Real-Time Fluorescent Cholangiography by Intrabiliary Indocyanine Green Administration With Near-Infrared Laparoscopy in Major Hepatectomy. Cureus 2023, 15, e40769. [Google Scholar] [CrossRef]
  166. Kawaguchi, Y.; Velayutham, V.; Fuks, D.; Christidis, C.; Kokudo, N.; Gayet, B. Usefulness of Indocyanine Green-Fluorescence Imaging for Visualization of the Bile Duct During Laparoscopic Liver Resection. J. Am. Coll. Surg. 2015, 221, e113–e117. [Google Scholar] [CrossRef]
  167. Tanaka, R.; Sonomura, T.; Ueno, M.; Hayami, S.; Ihira, H.; Ueda, S.; Okuhira, R.; Koike, M.; Higashino, N.; Kamisako, A.; et al. Hepatic Arterial Embolization with an Indocyanine Green-Lipiodol(®) Mixture before Laparoscopic Anatomical Liver Resection. Interv. Radiol. 2020, 5, 82–84. [Google Scholar] [CrossRef]
  168. Ruzzenente, A.; Conci, S.; Isa, G.; Campagnaro, T.; Pedrazzani, C.; De Bellis, M.; Marchitelli, I.; Castelli, C.; Pecori, S.; Guglielmi, A. The LIver SEntinel LYmph-node (LISELY) study: A prospective intraoperative real time evaluation of liver lymphatic drainage and sentinel lymph-node using near-infrared (NIR) imaging with Indocyanine Green (ICG). Eur. J. Surg. Oncol. 2022, 48, 2455–2459. [Google Scholar] [CrossRef]
  169. Wakabayashi, T.; Cacciaguerra, A.B.; Abe, Y.; Bona, E.D.; Nicolini, D.; Mocchegiani, F.; Kabeshima, Y.; Vivarelli, M.; Wakabayashi, G.; Kitagawa, Y. Indocyanine Green Fluorescence Navigation in Liver Surgery: A Systematic Review on Dose and Timing of Administration. Ann. Surg. 2022, 275, 1025–1034. [Google Scholar] [CrossRef]
  170. Ceccarelli, G.; Costa, G.; De Rosa, M.; Codacci Pisanelli, M.; Frezza, B.; De Prizio, M.; Bravi, I.; Scacchi, A.; Gallo, G.; Amato, B.; et al. Minimally Invasive Approach to Gastric GISTs: Analysis of a Multicenter Robotic and Laparoscopic Experience with Literature Review. Cancers 2021, 13, 4351. [Google Scholar] [CrossRef]
  171. Liu, R.Q.; Elnahas, A.; Tang, E.; Alkhamesi, N.A.; Hawel, J.; Alnumay, A.; Schlachta, C.M. Cost analysis of indocyanine green fluorescence angiography for prevention of anastomotic leakage in colorectal surgery. Surg. Endosc. 2022, 36, 9281–9287. [Google Scholar] [CrossRef] [PubMed]
  172. Nguyen, C.L.; Zhou, M.; Easwaralingam, N.; Seah, J.L.; Azimi, F.; Mak, C.; Pulitano, C.; Warrier, S. Novel Dual Tracer Indocyanine Green and Radioisotope Versus Gold Standard Sentinel Lymph Node Biopsy in Breast Cancer: The GREENORBLUE Trial. Ann. Surg. Oncol. 2023, 30, 6520–6527. [Google Scholar] [CrossRef] [PubMed]
  173. Reeves, J.J.; Broderick, R.C.; Lee, A.M.; Blitzer, R.R.; Waterman, R.S.; Cheverie, J.N.; Jacobsen, G.R.; Sandler, B.J.; Bouvet, M.; Doucet, J.; et al. The price is right: Routine fluorescent cholangiography during laparoscopic cholecystectomy. Surgery 2022, 171, 1168–1176. [Google Scholar] [CrossRef] [PubMed]
  174. Marino, M.V.; Mirabella, A.; Guarrasi, D.; Lupo, M.; Komorowski, A.L. Robotic-assisted repair of iatrogenic common bile duct injury after laparoscopic cholecystectomy: Surgical technique and outcomes. Int. J. Med. Robot. 2019, 15, e1992. [Google Scholar] [CrossRef]
  175. Aldrighetti, L.; Boggi, U.; Falconi, M.; Giuliante, F.; Cipriani, F.; Ratti, F.; Torzilli, G. Perspectives from Italy during the COVID-19 pandemic: Nationwide survey-based focus on minimally invasive HPB surgery. Updates Surg. 2020, 72, 241–247. [Google Scholar] [CrossRef]
Figure 1. PRISMA Flowchart of our systematic analysis.
Figure 1. PRISMA Flowchart of our systematic analysis.
Cancers 17 00872 g001
Figure 2. (A) Percentage of open, laparoscopic, and robotic surgery involved in our review. In 1 report, the type of surgery was not specified; (B) Percentage of clinical applications detected.
Figure 2. (A) Percentage of open, laparoscopic, and robotic surgery involved in our review. In 1 report, the type of surgery was not specified; (B) Percentage of clinical applications detected.
Cancers 17 00872 g002
Figure 3. Indocyanine green fluorescence imaging in HCC, CRLM, and CCA during liver surgery. Abbreviations: HCC, Hepatocellular Carcinoma; CRLM, Colorectal Liver Metastases; CCA, Cholangiocellular Carcinoma.
Figure 3. Indocyanine green fluorescence imaging in HCC, CRLM, and CCA during liver surgery. Abbreviations: HCC, Hepatocellular Carcinoma; CRLM, Colorectal Liver Metastases; CCA, Cholangiocellular Carcinoma.
Cancers 17 00872 g003
Figure 4. The flowchart of ICG doses and timing according to our systematic review. The syringe indicates intravenous administration, while the biliary tree implies trans-biliary duct administration. No protocols were reported for cholangiocarcinoma detection due to limited data availability. Abbreviations: HCC, Hepatocellular Carcinoma; CRLM, Colorectal Liver Metastases; BD, Bile Duct.
Figure 4. The flowchart of ICG doses and timing according to our systematic review. The syringe indicates intravenous administration, while the biliary tree implies trans-biliary duct administration. No protocols were reported for cholangiocarcinoma detection due to limited data availability. Abbreviations: HCC, Hepatocellular Carcinoma; CRLM, Colorectal Liver Metastases; BD, Bile Duct.
Cancers 17 00872 g004
Table 1. Patients, intervention, comparison, outcomes, and study design method used to screen experiences in the literature.
Table 1. Patients, intervention, comparison, outcomes, and study design method used to screen experiences in the literature.
PopulationPatients Who Underwent Open, Laparoscopic, or Robotic Liver Surgery
InterventionDose and timing of ICG administration for benign and malignant liver neoplasm or cysts
ComparatorDifferent protocols of administration in terms of dose and timing
OutcomesTumor detection, segmentation, bile leak, lymph nodes identifications, and vascular and biliary anatomy recognition
Study designRandomized Clinical Trials (RCTs), controlled cohort studies, case series, and case reports which met inclusion criteria
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Avella, P.; Spiezia, S.; Rotondo, M.; Cappuccio, M.; Scacchi, A.; Inglese, G.; Guerra, G.; Brunese, M.C.; Bianco, P.; Tedesco, G.A.; et al. Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications. Cancers 2025, 17, 872. https://doi.org/10.3390/cancers17050872

AMA Style

Avella P, Spiezia S, Rotondo M, Cappuccio M, Scacchi A, Inglese G, Guerra G, Brunese MC, Bianco P, Tedesco GA, et al. Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications. Cancers. 2025; 17(5):872. https://doi.org/10.3390/cancers17050872

Chicago/Turabian Style

Avella, Pasquale, Salvatore Spiezia, Marco Rotondo, Micaela Cappuccio, Andrea Scacchi, Giustiniano Inglese, Germano Guerra, Maria Chiara Brunese, Paolo Bianco, Giuseppe Amedeo Tedesco, and et al. 2025. "Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications" Cancers 17, no. 5: 872. https://doi.org/10.3390/cancers17050872

APA Style

Avella, P., Spiezia, S., Rotondo, M., Cappuccio, M., Scacchi, A., Inglese, G., Guerra, G., Brunese, M. C., Bianco, P., Tedesco, G. A., Ceccarelli, G., & Rocca, A. (2025). Real-Time Navigation in Liver Surgery Through Indocyanine Green Fluorescence: An Updated Analysis of Worldwide Protocols and Applications. Cancers, 17(5), 872. https://doi.org/10.3390/cancers17050872

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop