Simulation and Performance Evaluation of Laser Heterodyne Spectrometer Based on CO2 Absorption Cell

1
Space Laser Engineering Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
2
Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
3
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
4
Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao 266237, China
5
College of Science, Donghua University, Shanghai 201620, China
*
Author to whom correspondence should be addressed.
Remote Sens. 2023, 15(3), 788; https://doi.org/10.3390/rs15030788
Submission received: 23 November 2022 / Revised: 15 January 2023 / Accepted: 28 January 2023 / Published: 30 January 2023

Abstract

The laser heterodyne radiometer (LHR) has the advantages of miniaturization, low cost, and high spectral-resolution as a ground-verification instrument for satellite observation of atmospheric trace-gas concentration. To verify the accuracy of LHR measurements, a new performance evaluation method is presented here, based on an ASE source and a CO2 absorption cell in the laboratory. Preliminary simulation analysis based on the system parameters of LHR is carried out for the performance analysis and data processing of this new combined test system. According to the simulation results, at wavelength deviation of fewer than 30 MHz, the retrieval error, which increases with bandwidth, can obtain an accuracy of 1 ppm within the bandwidth range of the photodetector (1.2 GHz) when this instrument line shape (ILS) is calibrated. Meanwhile, when the filter bandwidth is less than 200 MHz, the maximum error without ILS correction does not exceed 0.07 ppm. Moreover, with an ideal 60 MHz bandpass filter without ILS correction, LHR’s signal-to-noise ratio (SNR) should be greater than 20 to achieve retrieval results of less than 1 ppm. When the SNR is 100, the retrieval error is 0.206 and 0.265 ppm, corresponding to whether the system uncertainties (temperature and pressure) are considered. Considering all the error terms, the retrieval error (geometrically added) is 0.528 ppm at a spectral resolution of 0.004 cm−1, which meets the measurement accuracy requirement of 1 ppm. In the experiment, the retrieval and analysis of the heterodyne signals are performed for different XCO2 with [400 ppm, 420 ppm] in the absorption cell. Experimental results match well with the simulation, and confirm the accuracy of LHR with an error of less than 1 ppm with an SNR of 100. The LHR will be used to measure atmospheric-CO2 column concentrations in the future, and could be effective validation instruments on the ground for spaceborne CO2-sounding sensors.
Keywords: LHR; CO2 absorption cell; ILS; SNR; XCO2 LHR; CO2 absorption cell; ILS; SNR; XCO2

Share and Cite

MDPI and ACS Style

Xia, T.; Liu, J.; Liu, Z.; Yue, F.; Yang, F.; Zhu, X.; Chen, W. Simulation and Performance Evaluation of Laser Heterodyne Spectrometer Based on CO2 Absorption Cell. Remote Sens. 2023, 15, 788. https://doi.org/10.3390/rs15030788

AMA Style

Xia T, Liu J, Liu Z, Yue F, Yang F, Zhu X, Chen W. Simulation and Performance Evaluation of Laser Heterodyne Spectrometer Based on CO2 Absorption Cell. Remote Sensing. 2023; 15(3):788. https://doi.org/10.3390/rs15030788

Chicago/Turabian Style

Xia, Tengteng, Jiqiao Liu, Zheng Liu, Fangxin Yue, Fu Yang, Xiaopeng Zhu, and Weibiao Chen. 2023. "Simulation and Performance Evaluation of Laser Heterodyne Spectrometer Based on CO2 Absorption Cell" Remote Sensing 15, no. 3: 788. https://doi.org/10.3390/rs15030788

APA Style

Xia, T., Liu, J., Liu, Z., Yue, F., Yang, F., Zhu, X., & Chen, W. (2023). Simulation and Performance Evaluation of Laser Heterodyne Spectrometer Based on CO2 Absorption Cell. Remote Sensing, 15(3), 788. https://doi.org/10.3390/rs15030788

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop