Next Article in Journal
Thermal Displacement with CO2 for E-CBM Recovery: Mechanisms and Efficacy of Temperature–Pressure Synergy in Permeability Enhancement
Next Article in Special Issue
Effect of Gear Ratio on the Optimal Geometric Parameters in a Reluctance Magnetic Gear: A Multi-Objective Optimization Study
Previous Article in Journal
Analysis on Energy Conservation and Carbon Reduction Potential of Road and Tunnel LED Lighting Driven by GB 37478 Standard and Its Policy Implications
Previous Article in Special Issue
Development and Optimization of a 10-Stage Solid-State Linear Transformer Driver
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Novel Fault Ranging Method for High-Voltage AC Transmission Lines Based on Attention-GRU and Modulus Amplitude Ratio

1
Yunnan Power Grid Co., Ltd., Kunming 650011, China
2
XJ Electric Co., Ltd., Xuchang 461000, China
3
School of Automation, Guangdong University of Technology, Guangzhou 510006, China
*
Author to whom correspondence should be addressed.
Energies 2026, 19(2), 494; https://doi.org/10.3390/en19020494
Submission received: 5 December 2025 / Revised: 5 January 2026 / Accepted: 12 January 2026 / Published: 19 January 2026
(This article belongs to the Special Issue Advancements in Electromagnetic Technology for Electrical Engineering)

Abstract

Existing high-voltage alternating current (AC) transmission line fault ranging methods have several drawbacks, including weak transition resistance, a complicated feature extraction process, and difficult calibration of the travelling wave head. To address these issues, a single-end fault ranging method for high-voltage AC transmission lines based on Attention-GRU and modulus amplitude ratio is proposed. Firstly, based on the travelling wave dispersion characteristics, an approximate formula is derived between the fault distance of the high-voltage AC transmission line and the amplitude ratio of the sum of the initial transient voltage travelling wave modes 1 and 2 and the mode 0 components at the ranging location. This shows that a definite nonlinear mapping relationship exists between the two. Secondly, the Attention-GRU is constructed using the multiscale wavelet modal maxima ratio between the sum of the initial transient voltage travelling wave mode 1 and 2 components and the mode 0 component as the input eigenquantities and the fault distance as the output quantity. The fault distance is then calculated using the Attention-GRU and the modal amplitude ratio. The Attention-GRU neural network fault ranging model is then constructed using the distance as the output quantity. After training is completed, the fault feature quantities obtained from the measurement points are inputted into the Attention-GRU model to achieve the purpose of fault ranging. The ranging ability of this model is then compared with that of other neural network models. A large number of simulations verify that the proposed method has high ranging accuracy and that the ranging capability is not affected by the fault type, transition resistance or the initial phase angle of the fault.
Keywords: high-voltage AC transmission line; fault ranging; the multiscale wavelet modal maxima ratio; Attention-GRU neural network high-voltage AC transmission line; fault ranging; the multiscale wavelet modal maxima ratio; Attention-GRU neural network

Share and Cite

MDPI and ACS Style

Yin, S.; Xing, X.; Zhang, B.; Hui, S.; Chen, Y.; Tong, N. A Novel Fault Ranging Method for High-Voltage AC Transmission Lines Based on Attention-GRU and Modulus Amplitude Ratio. Energies 2026, 19, 494. https://doi.org/10.3390/en19020494

AMA Style

Yin S, Xing X, Zhang B, Hui S, Chen Y, Tong N. A Novel Fault Ranging Method for High-Voltage AC Transmission Lines Based on Attention-GRU and Modulus Amplitude Ratio. Energies. 2026; 19(2):494. https://doi.org/10.3390/en19020494

Chicago/Turabian Style

Yin, Shihao, Xiaodong Xing, Bin Zhang, Shixian Hui, Yunchuan Chen, and Ning Tong. 2026. "A Novel Fault Ranging Method for High-Voltage AC Transmission Lines Based on Attention-GRU and Modulus Amplitude Ratio" Energies 19, no. 2: 494. https://doi.org/10.3390/en19020494

APA Style

Yin, S., Xing, X., Zhang, B., Hui, S., Chen, Y., & Tong, N. (2026). A Novel Fault Ranging Method for High-Voltage AC Transmission Lines Based on Attention-GRU and Modulus Amplitude Ratio. Energies, 19(2), 494. https://doi.org/10.3390/en19020494

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics