Next Article in Journal
Real-Time Monocular Visual Odometry for Turbid and Dynamic Underwater Environments
Previous Article in Journal
Towards Gas Discrimination and Mapping in Emergency Response Scenarios Using a Mobile Robot with an Electronic Nose
Previous Article in Special Issue
Towards Using the Instrumented Timed Up-and-Go Test for Screening of Sensory System Performance for Balance Control in Older Adults
Open AccessCommunication

Development and Validation of Ambulosono: A Wearable Sensor for Bio-Feedback Rehabilitation Training

1
Department of Clinical Neurosciences, Hotchkiss Brain Institute, University of Calgary, Calgary, AB T2N 4N1, Canada
2
Alberta Children’s Hospital Research Institute, Calgary, AB T2N 4N1, Canada
3
Cumming School of Medicine Bachelor of Health Sciences, University of Calgary, Calgary, AB T2N 4N1, Canada
4
Faculty of Medicine and Dentistry, University of Alberta, T6G 2R7, Edmonton, AB, Canada
5
Softwisys Professionals Inc., Calgary, AB T2L 2K7, Canada
6
Electronic Innovation Inc., Calgary, AB T2W 1Z7, Canada
*
Authors to whom correspondence should be addressed.
These authors contributed equally.
Sensors 2019, 19(3), 686; https://doi.org/10.3390/s19030686
Received: 11 January 2019 / Revised: 28 January 2019 / Accepted: 1 February 2019 / Published: 8 February 2019
(This article belongs to the Special Issue Sensors to Manage Chronic Complications)
Wearable technology-based measurement systems hold potential for the therapeutic and rehabilitation management of patients with various chronic diseases. The purpose of this study was to assess the accuracy and test–retest reliability of a new-generation wearable sensor-based system, dubbed Ambulosono, for bio-feedback training. The Ambulosono sensor system was cross-validated by comparing its functionality with the iPod touch (4th generation) sensor system. Fifteen participants underwent a gait test to measure various gait parameters while wearing both the iPod-based and Ambulosono sensors simultaneously. The physically measured values (i.e., the true values) of step length, distance traveled, velocity, and cadence were then compared to those obtained via the two-sensor systems using the same calculation algorithms. While the mean percentage error was <10% for all measured parameters, and the intra-class correlation coefficient revealed a high level of agreement between trials for both sensor systems, it was found that the Ambulosono sensor system outperformed the iPod-based system in some respects. The Ambulosono sensor system possessed both reliability and accuracy in obtaining gait parameter measurements, which suggests it can serve as an economical alternative to the iPod-based system that is currently used in various clinical rehabilitation programs. View Full-Text
Keywords: wearable; sensors; Ambulosono; rehabilitation; gait wearable; sensors; Ambulosono; rehabilitation; gait