Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (18)

Search Parameters:
Keywords = ultrasound fetal biometry

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1221 KiB  
Article
Concordance Between Estimated Fetal Weight by Ultrasound and Birth Weight and Its Association with Adverse Perinatal Outcomes
by Cinara Carvalho Silva, Artur Bizinotto, Edward Araujo Júnior, Taciana Mara Rodrigues da Cunha Caldas, Alberto Borges Peixoto and Roberta Granese
J. Clin. Med. 2025, 14(5), 1757; https://doi.org/10.3390/jcm14051757 - 5 Mar 2025
Viewed by 1639
Abstract
Objective: The aim of this study was to analyze the concordance between estimated fetal weight (EFW) and birth weight among ultrasound examinations with fetal biometry considered adequate and inadequate according to the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guidelines, and [...] Read more.
Objective: The aim of this study was to analyze the concordance between estimated fetal weight (EFW) and birth weight among ultrasound examinations with fetal biometry considered adequate and inadequate according to the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guidelines, and its association with adverse perinatal outcomes. Methods: This was a retrospective and cross-sectional study carried out in two centers, involving parturients who delivered between 37 and 41 weeks. The following parameters were evaluated: biparietal (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) measurement; EFW; the interval between the ultrasound and delivery; and the discrepancy between EFW and birth weight. A minimum of 140 participants were required to assess the association between EFW and birth weight. Results: A total of 305 ultrasound examinations were selected and divided into two groups: adequate (Group I n = 115) and inadequate (Group II n = 190) fetal biometry. The measurements of the cephalic pole (BPD + HC), AC, and FL were inadequate in 69.5% (132/190), 91.6% (175/190), and 72.1% (137/190) of participants, respectively. Group I had a lower gestational age at ultrasound examination (38.4 vs. 39.9 weeks, p < 0.001), a larger BPD measurement (93.9 vs. 91.6 mm, p = 0.001), a longer interval between ultrasound examination and delivery (3.8 vs. 2.0 days, p < 0.001), and a smaller discrepancy between EFW and birth weight (7.2 vs. 9.5%, p = 0.002) than Group II. In Group I, EFW was a strong significant predictor (AUC:0.94, 95%CI 0.85–0.99, p = 0.032) for identifying birth weight >4000 g. An EFW cut-off value of 4019.0 g was found to be a correct identifier for 85.7% of newborns with a birth weight >4000 g, with a false-positive rate of 13.7%. Group I had a lower risk of postpartum hemorrhage (7.0% vs. 15.8%, OR:0.39, 95%CI 0.17–0.90, p = 0.024) and composite adverse perinatal outcomes (13.0 vs. 23.3%, OR:0.49, 95%CI 0.26–0.94, p = 0.030) than Group II. In Group I patients, undergoing an ultrasound 7 days before delivery was an independent predictor of composite adverse perinatal outcomes [x2(1) = 4.9, OR:0.49, 95%CI: 0.26–0.94, R2 Nagelkerke:0.026, p = 0.030]. Conclusions: We observed a high rate of inadequate fetal biometry. There was poor concordance between EFW and birth weight. EFW was a strong significant predictor for identifying macrosomia. Ultrasound examination performed 7 days before delivery was an independent predictor of adverse perinatal outcomes. Full article
(This article belongs to the Section Obstetrics & Gynecology)
Show Figures

Figure 1

13 pages, 3011 KiB  
Article
Quantitative Approach to Quality Review of Prenatal Ultrasound Examinations: Fetal Biometry
by C. Andrew Combs, Sushma Amara, Carolyn Kline, Olaide Ashimi Balogun and Zachary S. Bowman
J. Clin. Med. 2024, 13(16), 4860; https://doi.org/10.3390/jcm13164860 - 17 Aug 2024
Cited by 3 | Viewed by 1426
Abstract
Background/Objectives: To evaluate the quality of an ultrasound practice, both large-scale and focused audits are recommended by professional organizations, but such audits can be time-consuming, inefficient, and expensive. Our objective was to develop a time-efficient, quantitative, objective, large-scale method to evaluate fetal [...] Read more.
Background/Objectives: To evaluate the quality of an ultrasound practice, both large-scale and focused audits are recommended by professional organizations, but such audits can be time-consuming, inefficient, and expensive. Our objective was to develop a time-efficient, quantitative, objective, large-scale method to evaluate fetal biometry measurements for an entire practice, combined with a process for focused image review for personnel whose measurements are outliers. Methods: Ultrasound exam data for a full year are exported from commercial ultrasound reporting software to a statistical package. Fetal biometry measurements are converted to z-scores to standardize across gestational ages. For a large-scale audit, sonographer mean z-scores are compared using analysis of variance (ANOVA) with Scheffe multiple comparisons test. A focused image review is performed on a random sample of exams for sonographers whose mean z-scores differ significantly from the practice mean. A similar large-scale audit is performed, comparing physician mean z-scores. Results: Using fetal abdominal circumference measurements as an example, significant differences between sonographer mean z-scores are readily identified by the ANOVA and Scheffe test. A method is described for the blinded image audit of sonographers with outlier mean z-scores. Examples are also given for the identification and interpretation of several types of systematic errors that are unlikely to be detectable by image review, including z-scores with large or small standard deviations and physicians with outlier mean z-scores. Conclusions: The large-scale quantitative analysis provides an overview of the biometry measurements of all the sonographers and physicians in a practice, so that image audits can be focused on those whose measurements are outliers. The analysis takes little time to perform after initial development and avoids the time, complexity, and expense of auditing providers whose measurements fall within the expected range. We encourage commercial software developers to include tools in their ultrasound reporting software to facilitate such quantitative reviews. Full article
(This article belongs to the Special Issue Progress in Patient Safety and Quality in Maternal–Fetal Medicine)
Show Figures

Figure 1

11 pages, 2006 KiB  
Article
The Relationship between Placental Shear Wave Elastography and Fetal Weight—A Prospective Study
by Erika Cavanagh, Kylie Crawford, Jesrine Gek Shan Hong, Davide Fontanarosa, Christopher Edwards, Marie-Luise Wille, Jennifer Hong, Vicki L. Clifton and Sailesh Kumar
J. Clin. Med. 2024, 13(15), 4432; https://doi.org/10.3390/jcm13154432 - 29 Jul 2024
Cited by 1 | Viewed by 1937
Abstract
Background/Objectives: The utility of shear wave elastography (SWE) as an adjunct to ultrasound biometry and Doppler velocimetry for the examination of placental dysfunction and suboptimal fetal growth is unclear. To date, limited data exist correlating the mechanical properties of placentae with fetal [...] Read more.
Background/Objectives: The utility of shear wave elastography (SWE) as an adjunct to ultrasound biometry and Doppler velocimetry for the examination of placental dysfunction and suboptimal fetal growth is unclear. To date, limited data exist correlating the mechanical properties of placentae with fetal growth. This study aimed to investigate the relationship between placental shear wave velocity (SWV) and ultrasound estimated fetal weight (EFW), and to ascertain if placental SWV is a suitable proxy measure of placental function in the surveillance of small-for-gestational-age (SGA) pregnancies. Methods: This prospective, observational cohort study compared the difference in placental SWV between SGA and appropriate-for-gestational-age (AGA) pregnancies. There were 221 women with singleton pregnancies in the study cohort—136 (61.5%) AGA and 85 (38.5%) SGA. Fetal biometry, Doppler velocimetry, the deepest vertical pocket of amniotic fluid, and mean SWV were measured at 2–4-weekly intervals from recruitment to birth. Results: There was no difference in mean placental SWV in SGA pregnancies compared to AGA pregnancies, nor was there any relationship to EFW. Conclusions: Although other studies have shown some correlation between increased placental stiffness and SGA pregnancies, our investigation did not support this. The mechanical properties of placental tissue in SGA pregnancies do not result in placental SWVs that are apparently different from those of AGA controls. As this study did not differentiate between constitutionally or pathologically small fetuses, further studies in growth-restricted cohorts would be of benefit. Full article
Show Figures

Figure 1

10 pages, 1240 KiB  
Article
Accuracy of Estimated Fetal Weight Assessment in Fetuses with Congenital Diaphragmatic Hernia—Is the Hadlock Formula a Reliable Tool?
by Daria Kuchnowska, Albert Stachura, Przemyslaw Kosinski, Maciej Gawlak and Piotr Wegrzyn
J. Clin. Med. 2024, 13(12), 3392; https://doi.org/10.3390/jcm13123392 - 10 Jun 2024
Cited by 2 | Viewed by 1456
Abstract
Objectives: Congenital diaphragmatic hernia (CDH) is defined as organ protrusion from the abdominal to the thoracic cavity. The Hadlock formula is the most commonly used tool for calculating estimated fetal weight (EFW). The anatomical nature of CDH usually leads to underestimation of [...] Read more.
Objectives: Congenital diaphragmatic hernia (CDH) is defined as organ protrusion from the abdominal to the thoracic cavity. The Hadlock formula is the most commonly used tool for calculating estimated fetal weight (EFW). The anatomical nature of CDH usually leads to underestimation of the abdominal circumference, resulting in underestimation of fetal weight. Accurate weight estimation is essential before birth for counselling, preparation before surgery and ECMO. The research is made to compare the accuracy of Hadlock’s formula and Faschingbauer’s formula for fetal weight estimation in CDH fetuses population. Methods: In our study, we investigated differences between EFW and actual birthweight in 42 fetuses with CDH as compared to 80 healthy matched controls. EFW was calculated using the Hadlock formula and a recently introduced formula described by Faschingbauer et al., which was tailored for fetuses with CDH. Additionally, both of the formulas were adjusted for the interval between the ultrasound and delivery for both of the groups. Results: The majority of hernias were left-sided (92.8% vs. 7.2%). EFW adjusted for the interval between the ultrasound and delivery had the highest correlation with the actual birthweight in both, study group and controls. We compared the results for both tools and found the Hadlock formula to predict birthweight in CDH children with a 7.8 ± 5.5% error as compared to 7.9 ± 6.5% error for the Faschingbauer’s formula. Conclusions: The Hadlock formula adjusted for the interval between the ultrasound and delivery is a more precise method of calculating EFW in fetuses with CDH. Routine biometry scan using Hadlock’s formula remains reliable for predicting birthweight. Full article
(This article belongs to the Special Issue Clinical Outcomes in Maternal–Fetal Medicine)
Show Figures

Figure 1

15 pages, 4514 KiB  
Article
Cardiac Adaptation and Preferential Streaming in Fetuses with Multiple Nuchal Cords
by Julia Murlewska, Sławomir Witkowski, Łucja Biały, Maria Respondek-Liberska, Maciej Słodki and Iwona Strzelecka
Diagnostics 2024, 14(1), 77; https://doi.org/10.3390/diagnostics14010077 - 28 Dec 2023
Cited by 1 | Viewed by 1426
Abstract
The echocardiographic monitoring of a fetus with multiple nuchal cords around the fetal neck is important as it may result in cardiac remodeling and preferential streaming, thus affecting the condition of the fetus. The main aim of our study was to assess whether [...] Read more.
The echocardiographic monitoring of a fetus with multiple nuchal cords around the fetal neck is important as it may result in cardiac remodeling and preferential streaming, thus affecting the condition of the fetus. The main aim of our study was to assess whether the collision of the umbilical cord around the fetal neck can lead to discrepancies in the size of the pulmonary artery and the aorta in the three-vessel view and to an increase in the size of the heart, which may result from the compression of the carotid arteries caused by the umbilical cord wrapping around the fetal neck. A total number of 854 patients were included in this study and divided into three groups. Group A (control group) included 716 fetuses (84%) without the umbilical cord around the fetal neck. Group B (study group B) included 102 fetuses (12%) with one coil of the umbilical cord around the fetal neck. Group C (study group C) included 32 fetuses (4%) with two coils of the umbilical cord around the fetal neck. The range of the gestational age of the patients considered for this study was 27–40.2 weeks based on the ultrasound biometry and was not statistically different between the analyzed groups A, B and C (p > 0.05). The Pa/Ao index was calculated by dividing the value of the width of the pulmonary artery (in mm) to the width of the aorta (in mm) measured in the ultrasound three-vessel view. We found that fetuses that the fetuses with one and two coils of the umbilical cord around the neck showed significantly higher values of the width of the pulmonary trunk with the unchanged value of the aorta width. Therefore, we also observed significantly higher values of the ratio of the pulmonary trunk to the aorta for the fetuses wrapped with the umbilical cord around the neck compared with the control group without the umbilical cord around the neck (. Moreover, in the fetuses with one and two coils of the umbilical cord around the fetal neck, an increased amount of amniotic fluid was observed, whereas larger dimensions of CTAR in the fetuses with two coils of the umbilical cord around the neck were present (p < 0.05). The wrapping of the fetus with the umbilical cord around the fetal neck may induce the redistribution of blood flow, leading to fetal heart enlargement and disproportion and may be the cause of polyhydramnios. Full article
(This article belongs to the Special Issue Advances in Fetal Cardiology)
Show Figures

Figure 1

13 pages, 1215 KiB  
Article
Multimodal Early Birth Weight Prediction Using Multiple Kernel Learning
by Lisbeth Camargo-Marín, Mario Guzmán-Huerta, Omar Piña-Ramirez and Jorge Perez-Gonzalez
Sensors 2024, 24(1), 2; https://doi.org/10.3390/s24010002 - 19 Dec 2023
Cited by 2 | Viewed by 2006
Abstract
In this work, a novel multimodal learning approach for early prediction of birth weight is presented. Fetal weight is one of the most relevant indicators in the assessment of fetal health status. The aim is to predict early birth weight using multimodal maternal–fetal [...] Read more.
In this work, a novel multimodal learning approach for early prediction of birth weight is presented. Fetal weight is one of the most relevant indicators in the assessment of fetal health status. The aim is to predict early birth weight using multimodal maternal–fetal variables from the first trimester of gestation (Anthropometric data, as well as metrics obtained from Fetal Biometry, Doppler and Maternal Ultrasound). The proposed methodology starts with the optimal selection of a subset of multimodal features using an ensemble-based approach of feature selectors. Subsequently, the selected variables feed the nonparametric Multiple Kernel Learning regression algorithm. At this stage, a set of kernels is selected and weighted to maximize performance in birth weight prediction. The proposed methodology is validated and compared with other computational learning algorithms reported in the state of the art. The obtained results (absolute error of 234 g) suggest that the proposed methodology can be useful as a tool for the early evaluation and monitoring of fetal health status through indicators such as birth weight. Full article
Show Figures

Figure 1

24 pages, 1023 KiB  
Systematic Review
The Current Knowledge of Cerebral Magnetic Resonance Imaging in Monochorionic Twins: A Systematic Review of the Last 20 Years
by Mathies Rondagh, Enrico Lopriore, Linda S. de Vries, Femke Slaghekke, Lisanne S. A. Tollenaar, Jeanine M. M. van Klink, Sophie G. Groene and Sylke J. Steggerda
J. Clin. Med. 2023, 12(23), 7211; https://doi.org/10.3390/jcm12237211 - 21 Nov 2023
Cited by 6 | Viewed by 2316
Abstract
The distinct placental angioarchitecture in monochorionic (MC) pregnancies increases the risk of complications such as twin–twin transfusion syndrome (TTTS), twin anemia polycythemia sequence (TAPS), and selective fetal growth restriction (sFGR). The aim of this systematic review was to evaluate the incidence, type, and [...] Read more.
The distinct placental angioarchitecture in monochorionic (MC) pregnancies increases the risk of complications such as twin–twin transfusion syndrome (TTTS), twin anemia polycythemia sequence (TAPS), and selective fetal growth restriction (sFGR). The aim of this systematic review was to evaluate the incidence, type, and severity of cerebral injury and structural brain development on fetal and/or neonatal cerebral magnetic resonance imaging (MRI) in MC twins with or without complications. Twenty-three studies were included, covering a wide range of complications observed during MC pregnancies, with studies involving sIUFD (n = 12), TTTS (n = 7), mixed complications (n = 2), TAPS (n = 1), and uncomplicated MC pregnancy (n = 1). TAPS and sFGR were largely underrepresented in the current literature. The included studies reported that MC pregnancies with single intrauterine fetal demise (sIUFD) are most at risk for cerebral injury during the fetal period. The overall median incidence of cerebral injury after sIUFD was 28.3% (0–55%). Severe antenatal cerebral injury after sIUFD was detected antenatally in 6.5% (0–36%) of the cases. Three of the included studies described the incidence, type, and severity of cerebral injury on neonatal MRI in MC twins. Structural brain development based on cerebral biometry was only assessed in two studies, revealing significantly smaller biometric measurements of the cerebrum in cases of single sIUFD or smaller twins compared to singleton pregnancies. To enhance our understanding of the potential risks and pathophysiological mechanisms associated with cerebral injury and structural brain development in MC twins, there is a need for future studies and standardized protocols using serial fetal and neonatal MRI imaging in addition to routine ultrasound imaging. Full article
(This article belongs to the Special Issue Improving Perinatal Outcomes in Twin and Multiple Pregnancy: Part II)
Show Figures

Figure 1

31 pages, 3442 KiB  
Systematic Review
Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology
by Elena Jost, Philipp Kosian, Jorge Jimenez Cruz, Shadi Albarqouni, Ulrich Gembruch, Brigitte Strizek and Florian Recker
J. Clin. Med. 2023, 12(21), 6833; https://doi.org/10.3390/jcm12216833 - 29 Oct 2023
Cited by 27 | Viewed by 5985
Abstract
Artificial intelligence (AI) has gained prominence in medical imaging, particularly in obstetrics and gynecology (OB/GYN), where ultrasound (US) is the preferred method. It is considered cost effective and easily accessible but is time consuming and hindered by the need for specialized training. To [...] Read more.
Artificial intelligence (AI) has gained prominence in medical imaging, particularly in obstetrics and gynecology (OB/GYN), where ultrasound (US) is the preferred method. It is considered cost effective and easily accessible but is time consuming and hindered by the need for specialized training. To overcome these limitations, AI models have been proposed for automated plane acquisition, anatomical measurements, and pathology detection. This study aims to overview recent literature on AI applications in OB/GYN US imaging, highlighting their benefits and limitations. For the methodology, a systematic literature search was performed in the PubMed and Cochrane Library databases. Matching abstracts were screened based on the PICOS (Participants, Intervention or Exposure, Comparison, Outcome, Study type) scheme. Articles with full text copies were distributed to the sections of OB/GYN and their research topics. As a result, this review includes 189 articles published from 1994 to 2023. Among these, 148 focus on obstetrics and 41 on gynecology. AI-assisted US applications span fetal biometry, echocardiography, or neurosonography, as well as the identification of adnexal and breast masses, and assessment of the endometrium and pelvic floor. To conclude, the applications for AI-assisted US in OB/GYN are abundant, especially in the subspecialty of obstetrics. However, while most studies focus on common application fields such as fetal biometry, this review outlines emerging and still experimental fields to promote further research. Full article
(This article belongs to the Special Issue Clinical Imaging Applications in Obstetrics and Gynecology)
Show Figures

Figure 1

16 pages, 3290 KiB  
Article
Predictive Value of Cervical Shear Wave Elastography in the Induction of Labor in Late-Term Pregnancy Nulliparous Women: Preliminary Results
by Tatiana Costas, María de la O Rodríguez, Mercedes Sánchez-Barba and Juan Luis Alcázar
Diagnostics 2023, 13(10), 1782; https://doi.org/10.3390/diagnostics13101782 - 18 May 2023
Cited by 3 | Viewed by 2424
Abstract
The prediction of induction of labor continues to be a paradigm nowadays. Bishop Score is the traditional widely spread method but with a low reliability. Ultrasound cervical assessment has been proposed as an instrument of measurement. Shear wave elastography (SWE) should be a [...] Read more.
The prediction of induction of labor continues to be a paradigm nowadays. Bishop Score is the traditional widely spread method but with a low reliability. Ultrasound cervical assessment has been proposed as an instrument of measurement. Shear wave elastography (SWE) should be a promising tool in the prediction of the success of labor induction in nulliparous late-term pregnancies. Ninety-two women with nulliparous late-term pregnancies who were going to be induced were included in the study. A shear wave measurement of the cervix divided into six regions (inner, middle and outer in both cervical lips), cervical length and fetal biometry was performed by blinded investigators prior to routine hand cervical assessment (Bishop Score (BS)) and induction of labor. The primary outcome was success of induction. Sixty-three women achieved labor. Nine women did not, and they underwent a cesarean section due to failure to induce labor. SWE was significantly higher in the inner part of the posterior cervix (p < 0.0001). SWE showed an area under the curve (AUC): 0.809 (0.677–0.941) in the inner posterior part. For CL, AUC was 0.816 (0.692–0.984). BS AUC was 0.467 (0.283–0.651). The ICC of inter-observer reproducibility was ≥0.83 in each region of interest (ROI). The cervix elastic gradient seems to be confirmed. The inner part of the posterior cervical lip is the most reliable region to predict induction of labor results in SWE terms. In addition, cervical length seems to be one of the most important procedures in the prediction of induction. Both methods combined could replace the Bishop Score. Full article
(This article belongs to the Special Issue Advances in Gynecological Ultrasound)
Show Figures

Figure 1

15 pages, 8814 KiB  
Article
Developmental Ultrasound Characteristics in Guinea Pigs: Similarities with Human Pregnancy
by Alejandro A. Candia, Tamara Jiménez, Álvaro Navarrete, Felipe Beñaldo, Pablo Silva, Claudio García-Herrera, Amanda N. Sferruzzi-Perri, Bernardo J. Krause, Alejandro González-Candia and Emilio A. Herrera
Vet. Sci. 2023, 10(2), 144; https://doi.org/10.3390/vetsci10020144 - 10 Feb 2023
Cited by 7 | Viewed by 4400
Abstract
Background: Biometrical and blood flow examinations are fundamental for assessing fetoplacental development during pregnancy. Guinea pigs have been proposed as a good model to study fetal development and related gestational complications; however, longitudinal growth and blood flow changes in utero have not been [...] Read more.
Background: Biometrical and blood flow examinations are fundamental for assessing fetoplacental development during pregnancy. Guinea pigs have been proposed as a good model to study fetal development and related gestational complications; however, longitudinal growth and blood flow changes in utero have not been properly described. This study aimed to describe fetal and placental growth and blood flow of the main intrauterine vascular beds across normal guinea pig pregnancy and to discuss the relevance of this data for human pregnancy. Methods: Pregnant guinea pigs were studied from day 25 of pregnancy until term (day ~70) by ultrasound and Doppler assessment. The results were compared to human data from the literature. Results: Measurements of biparietal diameter (BPD), cranial circumference (CC), abdominal circumference, and placental biometry, as well as pulsatility index determination of umbilical artery, middle cerebral artery (MCA), and cerebroplacental ratio (CPR), were feasible to determine across pregnancy, and they could be adjusted to linear or nonlinear functions. In addition, several of these parameters showed a high correlation coefficient and could be used to assess gestational age in guinea pigs. We further compared these data to ultrasound variables from human pregnancy with high similarities. Conclusions: BPD and CC are the most reliable measurements to assess fetal growth in guinea pigs. Furthermore, this is the first report in which the MCA pulsatility index and CPR are described across guinea pig gestation. The guinea pig is a valuable model to assess fetal growth and blood flow distribution, variables that are comparable with human pregnancy. Full article
(This article belongs to the Special Issue Placentation in Mammals: Development, Function and Pathology)
Show Figures

Figure 1

16 pages, 2373 KiB  
Article
Fetal Growth Restriction: Comparison of Biometric Parameters
by Carolin Marchand, Jeanette Köppe, Helen Ann Köster, Kathrin Oelmeier, Ralf Schmitz, Johannes Steinhard, Arrigo Fruscalzo and Karol Kubiak
J. Pers. Med. 2022, 12(7), 1125; https://doi.org/10.3390/jpm12071125 - 11 Jul 2022
Cited by 11 | Viewed by 5260
Abstract
The aim of this study was to identify growth-restricted fetuses using biometric parameters and to assess the validity and clinical value of individual ultrasound parameters and ratios, such as transcerebellar diameter/abdominal circumference (TCD/AC), head circumference/abdominal circumference (HC/AC), and femur length/abdominal circumference (FL/AC). In [...] Read more.
The aim of this study was to identify growth-restricted fetuses using biometric parameters and to assess the validity and clinical value of individual ultrasound parameters and ratios, such as transcerebellar diameter/abdominal circumference (TCD/AC), head circumference/abdominal circumference (HC/AC), and femur length/abdominal circumference (FL/AC). In a retrospective single-center cross-sectional study, the biometric data of 9292 pregnancies between the 15th and 42nd weeks of gestation were acquired. Statistical analysis included descriptive data, quantile regression estimating the 10th and 90th percentiles, and multivariable analysis. We obtained clinically noticeable results in predicting small-for-gestational-age (SGA) and fetal growth restriction (FGR) fetuses at advanced weeks of gestation using the AC with a Youden index of 0.81 and 0.96, respectively. The other individual parameters and quotients were less suited to identifying cases of SGA and FGR. The multivariable analysis demonstrated the best results for identifying SGA and FGR fetuses with an area under the curve of 0.95 and 0.96, respectively. The individual ultrasound parameters were better suited to identifying SGA and FGR than the ratios. Amongst these, the AC was the most promising individual parameter, especially at advanced weeks of gestation. However, the highest accuracy was achieved with a multivariable model. Full article
(This article belongs to the Section Personalized Therapy and Drug Delivery)
Show Figures

Figure 1

10 pages, 2102 KiB  
Article
Accuracy of Fetal Biacromial Diameter and Derived Ultrasonographic Parameters to Predict Shoulder Dystocia: A Prospective Observational Study
by Marco La Verde, Pasquale De Franciscis, Clelia Torre, Angela Celardo, Giulia Grassini, Rossella Papa, Stefano Cianci, Carlo Capristo, Maddalena Morlando and Gaetano Riemma
Int. J. Environ. Res. Public Health 2022, 19(9), 5747; https://doi.org/10.3390/ijerph19095747 - 9 May 2022
Cited by 12 | Viewed by 3272
Abstract
Background and Objectives: Shoulder dystocia (ShD) is one of most dangerous obstetric complication. The objective of this study was to determine if the ultrasonographic fetal biacromial diameter (BA) and derived parameters could predict ShD in uncomplicated term pregnancies. Materials and Methods: We conducted [...] Read more.
Background and Objectives: Shoulder dystocia (ShD) is one of most dangerous obstetric complication. The objective of this study was to determine if the ultrasonographic fetal biacromial diameter (BA) and derived parameters could predict ShD in uncomplicated term pregnancies. Materials and Methods: We conducted a prospective observational study in a tertiary care university hospital from March 2021 to February 2022. We included all full-term pregnancies accepted for delivery that received an accurate ultrasonography (USG) scan before delivery. USG biometry and estimated fetal weight (EFW) were collected. Therefore, we evaluated the diameter of the mid-arm, the transverse thoracic diameter (TTD) and the biacromial diameter (BA). BA was estimated using Youssef’s formula: TTD + 2 mid-arm diameters. The primary outcome was the evaluation of BA and its related parameters (BA/biparietal diameter (BPD), BA/head circumference (HC) and BA–BPD in fetuses with ShD versus fetuses without ShD. Diagnostic accuracy for ShD of BA, BA/BPD, BA/HC and BA–BPD was evaluated using receiver operator curve (ROC) analysis. Results: 90 women were included in the analysis, four of these had ShD and required extra maneuvers after head delivery. BA was increased in fetuses with ShD (150.4 cm; 95% CI 133.2 cm to 167.6 cm) compared to no-ShD (133.5 cm; 95% CI 130.1 cm to 137.0 cm; p = 0.04). Significant differences were also found between ShD and no-ShD groups for BA/BPD (1.66 (95% CI 1.46 to 1.86) vs. 1.44 (95% CI 1.41 to 1.48); p = 0.04), BA/HC (0.45 (95% CI 0.40 to 0.49) vs. 0.39 (95% CI 0.38 to 0.40); p = 0.01), BA–BPD (60.0 mm (95% CI 42.4 to 77.6 cm) vs. 41.4 (95% CI 38.2 to 44.6); p = 0.03), respectively. ROC analysis showed an overall good accuracy for ShD, with an AUC of 0.821 (p = 0.001) for BA alone and 0.881 (p = 0.001), 0.857 (p = 0.016) and 0.867 (p = 0.013) for BA/BPD, BA–BPD and BA/HC, respectively. Conclusions: BA alone, as well as BA/BPD, BA/HC and BA–BPD might be useful predictors of ShD in uncomplicated term pregnancies. However, such evidence needs extensive confirmation by means of additional studies with large sample sizes, especially in case of pregnancies at high risk for ShD (i.e., gestational diabetes). Full article
Show Figures

Figure 1

12 pages, 1747 KiB  
Article
Personalized Model to Predict Small for Gestational Age at Delivery Using Fetal Biometrics, Maternal Characteristics, and Pregnancy Biomarkers: A Retrospective Cohort Study of Births Assisted at a Spanish Hospital
by Peña Dieste-Pérez, Ricardo Savirón-Cornudella, Mauricio Tajada-Duaso, Faustino R. Pérez-López, Sergio Castán-Mateo, Gerardo Sanz and Luis Mariano Esteban
J. Pers. Med. 2022, 12(5), 762; https://doi.org/10.3390/jpm12050762 - 8 May 2022
Cited by 3 | Viewed by 2565
Abstract
Small for gestational age (SGA) is defined as a newborn with a birth weight for gestational age < 10th percentile. Routine third-trimester ultrasound screening for fetal growth assessment has detection rates (DR) from 50 to 80%. For this reason, the addition of other [...] Read more.
Small for gestational age (SGA) is defined as a newborn with a birth weight for gestational age < 10th percentile. Routine third-trimester ultrasound screening for fetal growth assessment has detection rates (DR) from 50 to 80%. For this reason, the addition of other markers is being studied, such as maternal characteristics, biochemical values, and biophysical models, in order to create personalized combinations that can increase the predictive capacity of the ultrasound. With this purpose, this retrospective cohort study of 12,912 cases aims to compare the potential value of third-trimester screening, based on estimated weight percentile (EPW), by universal ultrasound at 35–37 weeks of gestation, with a combined model integrating maternal characteristics and biochemical markers (PAPP-A and β-HCG) for the prediction of SGA newborns. We observed that DR improved from 58.9% with the EW alone to 63.5% with the predictive model. Moreover, the AUC for the multivariate model was 0.882 (0.873–0.891 95% C.I.), showing a statistically significant difference with EPW alone (AUC 0.864 (95% C.I.: 0.854–0.873)). Although the improvements were modest, contingent detection models appear to be more sensitive than third-trimester ultrasound alone at predicting SGA at delivery. Full article
(This article belongs to the Special Issue Pregnancy Complication and Precision Medicine)
Show Figures

Figure 1

17 pages, 2273 KiB  
Article
Prediction of Late-Onset Small for Gestational Age and Fetal Growth Restriction by Fetal Biometry at 35 Weeks and Impact of Ultrasound–Delivery Interval: Comparison of Six Fetal Growth Standards
by Ricardo Savirón-Cornudella, Luis Mariano Esteban, Rocío Aznar-Gimeno, Peña Dieste-Pérez, Faustino R. Pérez-López, Jose Manuel Campillos, Berta Castán-Larraz, Gerardo Sanz and Mauricio Tajada-Duaso
J. Clin. Med. 2021, 10(13), 2984; https://doi.org/10.3390/jcm10132984 - 3 Jul 2021
Cited by 8 | Viewed by 3439
Abstract
Small-for-gestational-age (SGA) infants have been associated with increased risk of adverse perinatal outcomes (APOs). In this work, we assess the predictive ability of the ultrasound-estimated percentile weight (EPW) at 35 weeks of gestational age to predict late-onset SGA and APOs, according to six [...] Read more.
Small-for-gestational-age (SGA) infants have been associated with increased risk of adverse perinatal outcomes (APOs). In this work, we assess the predictive ability of the ultrasound-estimated percentile weight (EPW) at 35 weeks of gestational age to predict late-onset SGA and APOs, according to six growth standards, and whether the ultrasound–delivery interval influences the detection rate. To this purpose, we analyze a retrospective cohort study of 9585 singleton pregnancies. EPWs at 35 weeks were calculated to the customized Miguel Servet University Hospital (MSUH) and Figueras standards and the non-customized MSUH, Fetal Medicine Foundation (FMF), INTERGROWTH-21st, and WHO standards. As results of our analysis, for a 10% false positive rate, the detection rates for SGA ranged between 48.9% with the customized Figueras standard (AUC 0.82) and 60.8% with the non-customized FMF standard (AUC 0.87). Detection rates to predict SGA by ultrasound–delivery interval (1–6 weeks) show higher detection rates as intervals decrease. APOs detection rates ranged from 27.0% with FMF to 7.9% with the Figueras standard. In conclusion, the ability of EPW to predict SGA at 35 weeks is good for all standards, and slightly better for non-customized standards. The APO detection rate is significantly greater for non-customized standards. Full article
(This article belongs to the Special Issue Fetal Growth: What Is New in the Clinical Research?)
Show Figures

Figure 1

6 pages, 12555 KiB  
Article
Interventricular Septal Thickness as a Diagnostic Marker of Fetal Macrosomia
by Bartosz Szmyd, Małgorzata Biedrzycka, Filip Franciszek Karuga, Magdalena Rogut, Iwona Strzelecka and Maria Respondek-Liberska
J. Clin. Med. 2021, 10(5), 949; https://doi.org/10.3390/jcm10050949 - 1 Mar 2021
Cited by 12 | Viewed by 5978
Abstract
Serious complications in both mother and newborn arising as a result of fetal macrosomia indicate the need for early diagnosis and prevention. Unfortunately, current predictors, such as fetal biometry, fundal height, and amniotic fluid index, appear to be insufficient. Therefore, we decided to [...] Read more.
Serious complications in both mother and newborn arising as a result of fetal macrosomia indicate the need for early diagnosis and prevention. Unfortunately, current predictors, such as fetal biometry, fundal height, and amniotic fluid index, appear to be insufficient. Therefore, we decided to assess the predictive potential of interventricular septal thickness (IVST), as measured at ≥33 weeks of gestation. Two hundred and ninety-nine patients met the inclusion criteria: complete medical history including all necessary measurements—namely, IVST obtained by M-mode echocardiography, fetal biometry, and birth weight. The Statistica 13.1 PL software was used to generate the receiver operating curve. The optimal cut-off point (IVST of 4.7 mm) was selected using the Youden index method. The analysis of fetal biometry abnormalities resulted in 46.6% of macrosomia cases being correctly predicted; however, IVST analysis detected 71.4% of cases. IVST at ≥4.7 mm appears to have a higher sensitivity and negative predictive value (NPV) than routine ultrasound. Full article
(This article belongs to the Section Obstetrics & Gynecology)
Show Figures

Figure 1

Back to TopTop