Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (79)

Search Parameters:
Keywords = solar-powered refrigeration

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 4509 KiB  
Article
Numerical Simulation and Analysis of Performance of Switchable Film-Insulated Photovoltaic–Thermal–Passive Cooling Module for Different Design Parameters
by Cong Jiao, Zeyu Li, Tiancheng Ju, Zihan Xu, Zhiqun Xu and Bin Sun
Processes 2025, 13(8), 2471; https://doi.org/10.3390/pr13082471 - 5 Aug 2025
Abstract
Photovoltaic–thermal (PVT) technology has attracted considerable attention for its ability to significantly improve solar energy conversion efficiency by simultaneously providing electricity and heat during the day. PVT technology serves a purpose in condensers and subcoolers for passive cooling in refrigeration systems at night. [...] Read more.
Photovoltaic–thermal (PVT) technology has attracted considerable attention for its ability to significantly improve solar energy conversion efficiency by simultaneously providing electricity and heat during the day. PVT technology serves a purpose in condensers and subcoolers for passive cooling in refrigeration systems at night. In our previous work, we proposed a switchable film-insulated photovoltaic–thermal–passive cooling (PVT-PC) module to address the structural incompatibility between diurnal and nocturnal modes. However, the performance of the proposed module strongly depends on two key design parameters: the structural height and the vacuum level of the air cushion. In this study, a numerical model of the proposed module is developed to examine the impact of design and meteorological parameters on its all-day performance. The results show that diurnal performance remains stable across different structural heights, while nocturnal passive cooling power shows strong dependence on vacuum level and structural height, achieving up to 103.73 W/m2 at 10 mm height and 1500 Pa vacuum, which is comparable to unglazed PVT modules. Convective heat transfer enhancement, induced by changes in air cushion shape, is identified as the primary contributor to improved nocturnal cooling performance. Wind speed has minimal impact on electrical output but significantly enhances thermal efficiency and nocturnal convective cooling power, with a passive cooling power increase of up to 31.61%. In contrast, higher sky temperatures degrade nocturnal cooling performance due to diminished radiative exchange, despite improving diurnal thermal efficiency. These findings provide fundamental insights for optimizing the structural design and operational strategies of PVT-PC systems under varying environmental conditions. Full article
(This article belongs to the Special Issue Numerical Simulation of Flow and Heat Transfer Processes)
Show Figures

Figure 1

22 pages, 3505 KiB  
Review
Solar Energy Solutions for Healthcare in Rural Areas of Developing Countries: Technologies, Challenges, and Opportunities
by Surafel Kifle Teklemariam, Rachele Schiasselloni, Luca Cattani and Fabio Bozzoli
Energies 2025, 18(15), 3908; https://doi.org/10.3390/en18153908 - 22 Jul 2025
Viewed by 457
Abstract
Recently, solar energy technologies are a cornerstone of the global effort to transition towards cleaner and more sustainable energy systems. However, in many rural areas of developing countries, unreliable electricity severely impacts healthcare delivery, resulting in reduced medical efficiency and increased risks to [...] Read more.
Recently, solar energy technologies are a cornerstone of the global effort to transition towards cleaner and more sustainable energy systems. However, in many rural areas of developing countries, unreliable electricity severely impacts healthcare delivery, resulting in reduced medical efficiency and increased risks to patient safety. This review explores the transformative potential of solar energy as a sustainable solution for powering healthcare facilities, reducing dependence on fossil fuels, and improving health outcomes. Consequently, energy harvesting is a vital renewable energy source that captures abundant solar and thermal energy, which can sustain medical centers by ensuring the continuous operation of life-saving equipment, lighting, vaccine refrigeration, sanitation, and waste management. Beyond healthcare, it reduces greenhouse gas emissions, lowers operational costs, and enhances community resilience. To address this issue, the paper reviews critical solar energy technologies, energy storage systems, challenges of energy access, and successful solar energy implementations in rural healthcare systems, providing strategic recommendations to overcome adoption challenges. To fulfill the aims of this study, a focused literature review was conducted, covering publications from 2005 to 2025 in the Scopus, ScienceDirect, MDPI, and Google Scholar databases. With targeted investments, policy support, and community engagement, solar energy can significantly improve healthcare access in underserved regions and contribute to sustainable development. Full article
Show Figures

Figure 1

11 pages, 831 KiB  
Article
Assessment of Carbon Footprint for Organization in Frozen Processed Seafood Factory and Strategies for Greenhouse Gas Emission Reduction
by Phuanglek Iamchamnan, Somkiat Saithanoo, Thaweesak Putsukee and Sompop Intasuwan
Processes 2025, 13(7), 1990; https://doi.org/10.3390/pr13071990 - 24 Jun 2025
Viewed by 422
Abstract
This study aims to assess the carbon footprint for the organization of frozen processed seafood manufacturing plants and propose sustainable strategies for reducing greenhouse gas emissions. Organizational activity data from 2024 were utilized to evaluate the carbon footprint and develop targeted mitigation measures. [...] Read more.
This study aims to assess the carbon footprint for the organization of frozen processed seafood manufacturing plants and propose sustainable strategies for reducing greenhouse gas emissions. Organizational activity data from 2024 were utilized to evaluate the carbon footprint and develop targeted mitigation measures. The findings indicate that Scope 1 emissions amounted to 12,685 tons of CO2eq, Scope 2 emissions amounted to 15,403 tons of CO2eq, and Scope 3 emissions amounted to 31,564 tons of CO2eq. The total greenhouse gas emissions across all three scopes were 59,652 tons of CO2eq, with additional greenhouse gas emissions recorded at 34,027 tons of CO2eq. Mitigation measures were considered for activities contributing to at least 10% of emissions in each scope. In Scope 1, the use of R507 refrigerant in the production cooling system accounted for 9907 tons of CO2eq, representing 78.10% of emissions. In Scope 2, electricity consumption contributed 15,403 tons of CO2eq, constituting 100% of emissions. In Scope 3, the procurement of surimi (processed fish meat) was responsible for 20,844 tons of CO2eq, accounting for 66.04% of emissions. Based on these findings, key mitigation strategies were proposed. For Scope 1, reducing emissions involves preventive maintenance of cooling systems to prevent leaks, replacing corroded pipelines, installing shut-off valves, and switching to alternative refrigerants with no greenhouse gas emissions. For Scope 2, energy-saving initiatives include promoting electricity conservation within the organization, maintaining equipment for optimal efficiency, installing energy-saving devices such as variable speed drives (VSD), upgrading to high-efficiency motors, and utilizing renewable energy sources like solar power. For Scope 3, emissions can be minimized by sourcing raw materials from suppliers with certified carbon footprint labels, prioritizing purchases from producers committed to carbon reduction, and selecting suppliers closer to manufacturing sites to reduce transportation-related emissions. Implementing these strategies will contribute to sustainable greenhouse gas emission reductions. Full article
(This article belongs to the Special Issue Sustainable Waste Material Recovery Technologies)
Show Figures

Figure 1

13 pages, 2141 KiB  
Article
Guidelines for Reducing the Greenhouse Gas Emissions of a Frozen Seafood Processing Factory Towards Carbon Neutrality Goals
by Phuanglek Iamchamnan, Somkiat Saithanoo, Thaweesak Putsukee and Sompop Intasuwan
Processes 2025, 13(7), 1989; https://doi.org/10.3390/pr13071989 - 24 Jun 2025
Viewed by 468
Abstract
This research aims to calculate the Carbon Footprint for Organization of a plant manufacturing frozen processed seafood and propose strategies to reduce greenhouse gas (GHG) emissions following the Net-Zero Pathway, using 2024 as the baseline year. The findings indicate that Scope 1 emissions [...] Read more.
This research aims to calculate the Carbon Footprint for Organization of a plant manufacturing frozen processed seafood and propose strategies to reduce greenhouse gas (GHG) emissions following the Net-Zero Pathway, using 2024 as the baseline year. The findings indicate that Scope 1 emissions amounted to 12,685 tons of CO2 eq, Scope 2 emissions totaled 15,403 tons of CO2eq, and Scope 3 emissions reached 31,564 tons of CO2eq, leading to a combined total of 59,652 tons of CO2eq across all scopes, with an additional 34,027 tons of CO2eq from other GHG sources. To achieve net-zero emissions by 2050, annual reductions of 3.46% per category are required. The short-term target for 2028f aims to reduce emissions to 10,929 tons of CO2eq for Scope 1, 13,270 tons of CO2eq for Scope 2, and 27,194 tons of CO2eq for Scope 3, resulting in total emissions of 51,392 tons of CO2eq. The proposed reduction strategies include optimizing Scope 1 emissions by preventing leaks in R507 refrigerant systems, replacing corroded pipelines, installing shut-off valves, and switching to low-GHG refrigerants. For Scope 2, measures focus on reducing electricity consumption through energy conservation initiatives, carrying out regular machinery maintenance, installing Variable Speed Drives (VSDs), upgrading to high-efficiency motors, and integrating renewable energy sources such as solar power. For Scope 3, emissions from raw material procurement can be minimized by sourcing from certified suppliers with established product carbon footprints, prioritizing carbon reduction labeling, and selecting nearby suppliers to reduce transportation-related emissions. These strategies will support the organization in achieving carbon neutrality and progressing toward the net-zero goal. Full article
(This article belongs to the Special Issue Sustainable Waste Material Recovery Technologies)
Show Figures

Figure 1

18 pages, 1239 KiB  
Article
Optimized Demand Side Management for Refrigeration: Modeling and Case Study Insights from Kenya
by Josephine Nakato Kakande, Godiana Hagile Philipo and Stefan Krauter
Energies 2025, 18(13), 3258; https://doi.org/10.3390/en18133258 - 21 Jun 2025
Viewed by 289
Abstract
According to the International Institute of Refrigeration (IIR), 20% of worldwide electricity consumption is for refrigeration, with domestic refrigeration appliances comprising a fifth of this demand. As the uptake of renewable energy sources for on-grid and isolated electricity supply increases, the need for [...] Read more.
According to the International Institute of Refrigeration (IIR), 20% of worldwide electricity consumption is for refrigeration, with domestic refrigeration appliances comprising a fifth of this demand. As the uptake of renewable energy sources for on-grid and isolated electricity supply increases, the need for mechanisms to match demand and supply better and increase power system flexibility has led to enhanced attention on demand-side management (DSM) practices to boost technology, infrastructure, and market efficiencies. Refrigeration requirements will continue to rise with development and climate change. In this work, particle swarm optimization (PSO) is used to evaluate energy saving and load factor improvement possibilities for refrigeration devices at a site in Kenya, using a combination of DSM load shifting and strategic conservation, and based on appliance temperature evolution measurements. Refrigeration energy savings of up to 18% are obtained, and the load factor is reduced. Modeling is done for a hybrid system with grid, solar PV, and battery, showing a marginal increase in solar energy supply to the load relative to the no DSM case, while the grid portion of the load supply reduces by almost 25% for DSM relative to No DSM. Full article
(This article belongs to the Special Issue Research on Operation Optimization of Integrated Energy Systems)
Show Figures

Figure 1

24 pages, 4239 KiB  
Article
Thermodynamic and Exergetic Evaluation of a Newly Designed CSP Driven Cooling-Desalination Cogeneration System
by Hassan F. Elattar, Abdul Khaliq, Bassam S. Aljohani, Abdullah M. A. Alsharif and Hassanein A. Refaey
Processes 2025, 13(5), 1589; https://doi.org/10.3390/pr13051589 - 20 May 2025
Viewed by 538
Abstract
This investigation attempts to develop a tower solar collector-based system designed for the cogeneration of cooling and desalination. The traditional organic Rankine cycle (ORC) integrated with the ejector refrigeration cycle generates limited power and cooling at a single temperature. Acknowledging their [...] Read more.
This investigation attempts to develop a tower solar collector-based system designed for the cogeneration of cooling and desalination. The traditional organic Rankine cycle (ORC) integrated with the ejector refrigeration cycle generates limited power and cooling at a single temperature. Acknowledging their limitations, our present study uses an organic flash cycle (OFC) supported by solar heat combined with the two-phase ejector cycle and the reverse osmosis (RO) desalination unit. Since the OFC turbine is fed with two extra streams of fluid, therefore, it provides greater power to run the compressor of the ejector and pumps of the RO unit, resulting in the production of cooling at two different temperatures (refrigeration and air conditioning) and a higher mass flow rate of fresh water. A mathematical model is employed to assess the impact of coil curvature ratio, Rib height, and direct normal irradiation (DNI) on the temperature of the collector’s oil outlet. ANSYS-FLUENT conducts numerical simulations through computational fluid dynamics (CFD) analysis. The results indicate an ultimate increase in oil outlet temperature of 45% as the DNI increased from 450 to 1000 W/m2 at a curvature ratio of 0.095 when employing the 1st Rib. Further, a steady-state energy and exergy analysis is conducted to evaluate the performance of the proposed cogeneration, with different design parameters like DNI, coil curvature ratio, rib height, and OFC turbine inlet pressure. The energetic and exergetic efficiencies of the cogeneration system at DNI of 800 W/m2 are obtained as 16.67% and 6.08%, respectively. Exergetic assessment of the overall system shows that 29.57% is the exergy produced as cooling exergy, and the exergy accompanied by freshwater, 68.13%, is the exergy destroyed, and 2.3% is the exergy loss. The solar collector exhibits the maximum exergy destruction, followed by the ejector and RO pumps. Integrating multiple technologies into a system with solar input enhances efficiency, energy sustainability, and environmental benefits. Full article
(This article belongs to the Section Chemical Processes and Systems)
Show Figures

Figure 1

18 pages, 4199 KiB  
Article
Energy, Exergic and Economic Analyses of a Novel Hybrid Solar–Gas System for Producing Electrical Power and Cooling
by Qun Ge, Xiaoman Cao, Fumin Guo, Jianpeng Li, Cheng Wang and Gang Wang
Energies 2025, 18(10), 2480; https://doi.org/10.3390/en18102480 - 12 May 2025
Viewed by 307
Abstract
This paper aims to evaluate the feasibility and performances of a novel hybrid solar–gas system, which provides electric power and cooling. By using Ebsilon (V15.0) software, the operation, advanced exergic and economic analyses of this hybrid system are conducted. The analysis results show [...] Read more.
This paper aims to evaluate the feasibility and performances of a novel hybrid solar–gas system, which provides electric power and cooling. By using Ebsilon (V15.0) software, the operation, advanced exergic and economic analyses of this hybrid system are conducted. The analysis results show that the total electric power and energy efficiency of the hybrid system are 96.0 MW and 45.8%. The solar energy system contributes an electric power of 9.0 MW. The maximum cooling load is 69.66 MW. The exergic loss and exergic efficiency of the whole hybrid system are 119.1 MW and 44.6%. The combustion chamber (CC) has the maximum exergic loss (56.5 MW). The exergic loss and exergic efficiency of the solar direct steam generator (SDSG) are 28.5 MW and 36.2%. For the air compressor (AC), CC, heat recovery steam generator (HRSG) and refrigeration system (CSS), a considerable part of the exergic loss is exogenous. The avoidable exergic loss of the CC is 11.69 MW. For the SDSG, there is almost no avoidable exergic loss. Economic analysis shows that for the hybrid system, the levelized cost of energy is 0.08125 USD/kWh, and the dynamic recycling cycle is 5.8 years, revealing certain economic feasibility. The results of this paper will contribute to the future research and development of solar–gas hybrid utilization technology to a certain extent. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

33 pages, 2848 KiB  
Review
A Review on Phase-Change Materials (PCMs) in Solar-Powered Refrigeration Systems
by Yali Guo, Chufan Liang, Hui Liu, Luyuan Gong, Minle Bao and Shengqiang Shen
Energies 2025, 18(6), 1547; https://doi.org/10.3390/en18061547 - 20 Mar 2025
Cited by 2 | Viewed by 1465
Abstract
Over the past few years, the combination of solar power with refrigeration technology has matured, providing a promising solution for sustainable cooling. However, a key challenge remains, namely the inherent intermittency of solar energy. Due to its uneven temporal distribution, it is difficult [...] Read more.
Over the past few years, the combination of solar power with refrigeration technology has matured, providing a promising solution for sustainable cooling. However, a key challenge remains, namely the inherent intermittency of solar energy. Due to its uneven temporal distribution, it is difficult to ensure continuous 24 h operation when relying solely on solar energy. To address this issue, thermal energy storage technology has emerged as a viable solution. This paper presents a comprehensive systematic review of phase-change material (PCM) applications in solar refrigeration systems. It systematically categorizes solar energy conversion methodologies and refrigeration system configurations while elucidating the fundamental operational principles of each solar refrigeration system. A detailed examination of system components is provided, encompassing photovoltaic panels, condensers, evaporators, solar collectors, absorbers, and generators. The analysis further investigates PCM integration strategies with these components, evaluating integration effectiveness and criteria for PCM selection. The critical physical parameters of PCMs are comparatively analyzed, including phase transition temperature, latent heat capacity, specific heat, density, and thermal conductivity. Through conducting a critical analysis of existing studies, this review comprehensively evaluates current research progress within PCM integration techniques, methodological classification frameworks, performance enhancement approaches, and system-level implementation within solar refrigeration systems. The investigation concludes by presenting strategic recommendations for future research priorities based on a comprehensive systematic evaluation of technological challenges and knowledge gaps within the domain. Full article
Show Figures

Figure 1

30 pages, 111058 KiB  
Article
Multi-Criteria Optimal Operation Strategy for Photovoltaic Systems in Large-Scale Logistics Parks Concerning Climate Impact
by Kai Peng, Mingzhu Ma, Wenxuan Zhao and Rongpeng Zhang
Buildings 2025, 15(3), 377; https://doi.org/10.3390/buildings15030377 - 25 Jan 2025
Viewed by 856
Abstract
Solar power is widely regarded as one of the most promising renewable resources for generating electricity and reducing building energy consumption. Logistics parks, with their low-rise buildings and extensive rooftop areas, offer significant advantages for solar energy utilization via rooftop photovoltaics (PVs). However, [...] Read more.
Solar power is widely regarded as one of the most promising renewable resources for generating electricity and reducing building energy consumption. Logistics parks, with their low-rise buildings and extensive rooftop areas, offer significant advantages for solar energy utilization via rooftop photovoltaics (PVs). However, limited research has been conducted on the proper operational principles and optimized control strategies for the PV systems of logistics parks, particularly regarding the mismatch between power generation and the loads of various building types under varying climatic conditions. This study proposes four optimal PV operation strategies for large-scale logistics parks across diverse climatic regions, developed using a multi-criteria optimization approach. The strategies optimize the azimuth and tilt angles of PV panels under four adjustment frequencies: annual, semi-annual, seasonal, and monthly. The investigated strategies are validated in a 5500 m2 logistics park, comprising refrigerated storage, warehouses, sorting centers, and other facilities. The results indicate that the proposed strategies outperform conventional fixed-angle approaches, with the monthly adjustment strategy delivering the best performance. Economic costs are reduced by 9.26–17.02%, while self-sufficiency can be improved by 2.00–7.08%. Cold regions with high solar radiation show particularly significant benefits, with self-consumption increasing by 82.44–359.04%. This study provides valuable insights and practical guidelines for optimizing PV system operations in logistics parks, offering enhanced energy efficiency and cost-effectiveness. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

13 pages, 6092 KiB  
Article
Solar-Powered Freeze-Melting Desalination Model for Water and Simultaneous Cooling Applications
by Beatriz Castillo-Téllez, Margarita Castillo Téllez and Rosenberg J. Romero
Water 2025, 17(1), 107; https://doi.org/10.3390/w17010107 - 2 Jan 2025
Viewed by 1560
Abstract
Freeze-melting (F/M) desalination presents a sustainable and energy-efficient alternative to conventional desalination methods. In this study, we evaluated two solar-powered refrigeration systems, using BaCl2–NH3 and NH3–LiNO3 sorbent–refrigerant pairs, for seawater desalination and cooling applications. The NH3 [...] Read more.
Freeze-melting (F/M) desalination presents a sustainable and energy-efficient alternative to conventional desalination methods. In this study, we evaluated two solar-powered refrigeration systems, using BaCl2–NH3 and NH3–LiNO3 sorbent–refrigerant pairs, for seawater desalination and cooling applications. The NH3–LiNO3 system demonstrated a superior performance, achieving evaporator temperatures below −3 °C and producing up to 8 kg/day of ice. The system operated with a significantly lower energy consumption than the 3–6 kWh/m3 required by reverse osmosis (RO). Practical tests confirmed the dual functionality of the system, providing cooling for food preservation (maintaining 4 °C for 5 h) and climate control while producing desalinated water with total dissolved solids (TDS) levels of 3650 k/m3. Although the TDS remained above the WHO potable water standard, the output is suitable for irrigation and livestock watering. These results highlight the F/M desalination system’s potential to address water scarcity and cooling needs in resource-limited, off-grid regions, contributing to sustainable desalination technologies powered by renewable energy. Full article
Show Figures

Figure 1

23 pages, 8185 KiB  
Article
Energy and Exergy Performance Analysis of Solar-Assisted Thermo-Mechanical Vapor Compression Cooling System
by Hussein A. Al Khiro and Rabah Boukhanouf
Sustainability 2024, 16(19), 8625; https://doi.org/10.3390/su16198625 - 4 Oct 2024
Cited by 3 | Viewed by 2025
Abstract
Air conditioning is vital for indoor comfort but traditionally relies on vapor compression systems, which raise electricity demand and carbon emissions. This study presents a novel thermo-mechanical vapor compression system that integrates an ejector with a conventional vapor compression cycle, incorporating a thermally [...] Read more.
Air conditioning is vital for indoor comfort but traditionally relies on vapor compression systems, which raise electricity demand and carbon emissions. This study presents a novel thermo-mechanical vapor compression system that integrates an ejector with a conventional vapor compression cycle, incorporating a thermally driven second-stage compressor powered by solar energy. The goal is to reduce electricity consumption and enhance sustainability by leveraging renewable energy. A MATLAB® model was developed to analyze the energy and exergy performance using R1234yf refrigerant under steady-state conditions. This study compares four solar collectors—evacuated flat plate (EFPC), evacuated tube (ETC), basic flat plate (FPC), and compound parabolic (CPC) collectors—to identify the optimal configuration based on the collector area and costs. The results show a 31% reduction in mechanical compressor energy use and up to a 44% improvement in the coefficient of performance (COP) compared to conventional systems, with a condenser temperature of 65 °C, a thermal compression ratio of 0.8, and a heat source temperature of 150 °C. The evacuated flat plate collectors performed best, requiring 2 m2/kW of cooling capacity with a maximum exergy efficiency of 15% at 170 °C, while compound parabolic collectors offered the lowest initial costs. Overall, the proposed system shows significant potential for reducing energy costs and carbon emissions, particularly in hot climates. Full article
(This article belongs to the Section Energy Sustainability)
Show Figures

Figure 1

26 pages, 5563 KiB  
Article
Solar-Powered Combined Cooling, Heating, and Power Energy System with Phase-Change Material and Water Electrolysis: Thermo-Economic Assessment and Optimization
by Koorosh Aieneh, Sadegh Mehranfar, Mohammad Yazdi Sotoude, Shayan Sadeghi and Amin Mahmoudzadeh Andwari
Energies 2024, 17(13), 3309; https://doi.org/10.3390/en17133309 - 5 Jul 2024
Cited by 5 | Viewed by 1862
Abstract
A solar-powered combined cooling, heating, and power (CCHP) plant integrated with a water electrolysis unit is investigated in terms of energy, exergy, and exergo-economic (3E) assessments. A comprehensive parametric study and optimization is conducted following the thermodynamic and exergo-economic assessment of the proposed [...] Read more.
A solar-powered combined cooling, heating, and power (CCHP) plant integrated with a water electrolysis unit is investigated in terms of energy, exergy, and exergo-economic (3E) assessments. A comprehensive parametric study and optimization is conducted following the thermodynamic and exergo-economic assessment of the proposed system to evaluate the key performance parameters of the system for efficiency and economic factors. This system employs a heliostat field and a receiver tower by taking advantage of thermal energy from the sun and produces a continuous energy supply with an integrated phase-change material (PCM) tank to store the heat. In addition, a supercritical CO2 Rankine cycle (RC), an ejector refrigeration cooling (ERC) system, and a PEM water electrolyzer are coupled to produce cooling, heating, power, and hydrogen. Thermodynamic analysis indicates that the system exergy efficiency and energy efficiency are improved to 33.50% and 40.61%, respectively, while the total cost rate is 2875.74 USD/h and the total product cost per exergy unit is 25.65 USD/GJ. Additionally, the system produces a net generated power, heating load, and cooling load of 11.70, 13.92, and 2.60 MW, respectively, and a hydrogen production rate of 12.95 g/s. A two-objective optimization approach utilizing a non-dominated sorting genetic algorithm (NSGA) was performed, demonstrating that the system’s ideal design point offers a cost rate of 1263.35 USD/h and an exergetic efficiency of 34.17%. Full article
(This article belongs to the Special Issue Advances in Waste Heat Recovery and Integrated Energy Systems)
Show Figures

Figure 1

13 pages, 2069 KiB  
Case Report
A Case Study and Scientific Nexus of a Hybrid Solar and Wind Power Plant with a Heat Pump for Emission Decarbonization
by Konstantin V. Osintsev, Evgeny V. Solomin, Gleb N. Ryavkin and Nikita A. Pshenisnov
Sustainability 2024, 16(12), 5221; https://doi.org/10.3390/su16125221 - 19 Jun 2024
Viewed by 1269
Abstract
During the operation of any source of electrical energy, thermal energy is also generated. The heating of generator parts is accompanied by the loss of the efficiency of the entire system as a whole and eventually leads to failure. In order to remove [...] Read more.
During the operation of any source of electrical energy, thermal energy is also generated. The heating of generator parts is accompanied by the loss of the efficiency of the entire system as a whole and eventually leads to failure. In order to remove the heat load from generators based on renewable energy, such as wind turbines and solar panels, it is possible to use heat pumps based on various refrigerants. This article presents a comparative analysis of methods for evaluating the efficiency of the technological process, using the example of increasing the efficiency of the heat pump based on the heat produced by renewable energy installations. An example of improving the efficiency of a laboratory stand is used. Exergetic calculation, fluid selection, an analysis of external sources and emission reduction were performed. This thermal energy transmission system uses a solar panel as an additional low-potential source of heat. Options for increasing the energy efficiency of the installation are considered. An assessment of the reduction in emissions when using an equivalent diesel power plant was carried out using the developed mathematical model. Full article
Show Figures

Figure 1

27 pages, 4534 KiB  
Article
Optimal Design of a Renewable-Energy-Driven Integrated Cooling–Freshwater Cogeneration System
by Iman Janghorban Esfahani and Pouya Ifaei
Processes 2024, 12(6), 1164; https://doi.org/10.3390/pr12061164 - 5 Jun 2024
Cited by 3 | Viewed by 1812
Abstract
This study presents a novel approach that will address escalating demands for water and cooling in regions vulnerable to climate change through the proposal of an optimal integrated cooling–freshwater cogeneration system powered by renewable energy sources. Comprising three subsystems (integrated multi-effect evaporation distillation, [...] Read more.
This study presents a novel approach that will address escalating demands for water and cooling in regions vulnerable to climate change through the proposal of an optimal integrated cooling–freshwater cogeneration system powered by renewable energy sources. Comprising three subsystems (integrated multi-effect evaporation distillation, absorption heat pump, and vapor compression refrigeration (MAV); renewable energy unit incorporating solar panels, wind turbines, batteries, and hydrogen facilities (RHP/BH); and combined heat and power (CHP)), the system aims to produce both cooling and freshwater. By recovering cooling from combined desalination and refrigeration subsystems to chill the air taken into the gas turbine compressor, the system maximizes efficiency. Through the recovery of waste heat and employing an integrated thermo-environ-economic framework, a novel objective function, termed modified total annual cost (MTAC), is introduced for optimization. Using a genetic algorithm, parametric iterative optimization minimizes the MTAC. The results reveal that under optimum conditions, the MAV, RHP/BH, and CHP subsystems account for 67%, 58%, and 100% of total annual, exergy destruction, and environmental costs, respectively. Notably, the system exhibits lower sensitivity to fuel prices than renewable energy sources, suggesting a need for future research that will incorporate dynamic product prices and greater fuel consumption to produce enhanced operational robustness. Full article
(This article belongs to the Special Issue Optimal Design for Renewable Power Systems)
Show Figures

Figure 1

16 pages, 7136 KiB  
Article
Simulation Study on Performance of Solar-Powered Desiccant Wheel and Ground Source Heat Pump Air Conditioning in Qingdao
by Yicheng Wu, Litong Hou, Tianxi Su and Yongzhi Ma
Sustainability 2024, 16(8), 3105; https://doi.org/10.3390/su16083105 - 9 Apr 2024
Cited by 1 | Viewed by 1678
Abstract
In China, a large amount of the total energy consumption is made up of building energy, particularly in humid regions. The conventional vapor compression refrigeration systems cannot effectively control the indoor humid and thermal environment. Therefore, this article proposes a solar-powered desiccant wheel [...] Read more.
In China, a large amount of the total energy consumption is made up of building energy, particularly in humid regions. The conventional vapor compression refrigeration systems cannot effectively control the indoor humid and thermal environment. Therefore, this article proposes a solar-powered desiccant wheel and ground-source heat pump (SDW-GSHP) air conditioning system. The energy consumption of the system is mainly from sustainable sources of solar and geothermal energy, showcasing excellent energy efficiency and environmental friendliness. The desiccant wheel (DW) processes latent heat loads, and the GSHP processes the sensible heat load. The regeneration air of the DW is heated by a solar collector. The operational performance of the system was simulated by using TRNSYS during the typical summer week (15 July to 22 July) in Qingdao. The simulation results indicated that indoor temperature was maintained within 25.8–26.2 °C and the relative humidity was maintained in the range of 57–61%. The COP of the SDW-GSHP air conditioning system was 42.1% higher than that of the DW air conditioning system with electric heating regeneration, and electricity saved 43.7%. Full article
(This article belongs to the Section Energy Sustainability)
Show Figures

Figure 1

Back to TopTop