Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (36)

Search Parameters:
Keywords = radiopaque properties

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 2718 KB  
Article
Feasibility of a Fully Covered Self-Expandable Metal Stent with a Central Waist and a Long Removal String for Management of Malignant Distal Biliary Obstruction: A Multicenter Prospective Pilot Study
by Min Jae Yang, Dong Wook Lee, Dong Kee Jang, Kwang Bum Cho, Seok Jeong and Sung Ill Jang
J. Clin. Med. 2026, 15(14), 5612; https://doi.org/10.3390/jcm15145612 - 17 Jul 2026
Viewed by 334
Abstract
Background/Objectives: A fully covered self-expandable metal stent (FCSEMS) with a central waist and long retrieval string has recently been introduced for benign biliary strictures; however, its role in malignant biliary obstruction (MBO) remains unclear. This prospective, multicenter study evaluated the feasibility of [...] Read more.
Background/Objectives: A fully covered self-expandable metal stent (FCSEMS) with a central waist and long retrieval string has recently been introduced for benign biliary strictures; however, its role in malignant biliary obstruction (MBO) remains unclear. This prospective, multicenter study evaluated the feasibility of palliation for unresectable distal MBO. Methods: Between April 2022 and March 2023, patients with extrahepatic MBO were enrolled across six tertiary referral centers. The FCSEMS was a silicone-covered, cross-wired nitinol stent with an anti-migration central waist 2 mm narrower than both ends, three radiopaque markers, and a 10 cm retrieval string. Stent-related outcomes and adverse events were analyzed. Results: Both technical and clinical success rates were 100% (46/46). The median stent patency and survival times were 251 and 360 days, respectively. Stent dysfunction occurred in 18 patients (39.1%), including 10 with migration and 8 with occlusion. Stent migration was observed exclusively in the transpapillary stenting group and showed no significant association with stricture length, stent-bending angle, or the ratio of stent lengths above and below the maximal bending point. All the occluded stents were successfully removed. Early non-recurrent biliary obstruction (RBO) adverse events occurred in five patients (three with pancreatitis, one with bleeding, one with cholecystitis), whereas late non-RBO events were reported in three patients (two with cholecystitis, one with cholangitis). Conclusions: An FCSEMS with a central waist and retrieval string is feasible for the palliation of unresectable distal MBO. Optimization of the mechanical properties is warranted to minimize migration. Full article
Show Figures

Figure 1

26 pages, 5670 KB  
Article
Rare-Earth-Doped Tricalcium Phosphate: From Thin Films and Ceramics to Multifunctional Bone Cements
by Ivan V. Nikiforov, Evgeniya S. Zhukovskaya, Olga A. Levandnaya, Olga S. Antonova, Polina A. Krokhicheva, Margarita A. Goldberg, Ilde Incarnato, Angela De Bonis, Katia Barbaro, Viktoriya G. Yankova, Bogdan I. Lazoryak, Dina V. Deyneko and Julietta V. Rau
Coatings 2026, 16(6), 702; https://doi.org/10.3390/coatings16060702 - 11 Jun 2026
Viewed by 400
Abstract
The development of multifunctional biomaterials for bone repair requires precursors that combine bioactivity, moderate antimicrobial growth-inhibitory effect, and imaging. This study demonstrates the multifunctional versatility of a single family of rare-earth-doped β-tricalcium phosphates (β-TCPs), Ca9Eu(PO4)7 and Ca9 [...] Read more.
The development of multifunctional biomaterials for bone repair requires precursors that combine bioactivity, moderate antimicrobial growth-inhibitory effect, and imaging. This study demonstrates the multifunctional versatility of a single family of rare-earth-doped β-tricalcium phosphates (β-TCPs), Ca9Eu(PO4)7 and Ca9Dy(PO4)7, across three distinct formats: bioactive thin films (for implant coatings), brushite cements (for injectable bone fillers), and radiopaque PMMA bone composites (for load-bearing applications). This work serves as a proof-of-concept that the same doped phosphate precursors can address different clinical needs while retaining bioactivity, antimicrobial properties, and radiopacity. The phosphate precursors were synthesized via solid-state reaction. Pulsed laser deposition (PLD) was used to form amorphous, dense, and crack-free coatings, which exhibited excellent in vitro bioactivity through the rapid dissolution–reprecipitation of a carbonated apatite layer in simulated body fluid. The brushite-based bone cements were produced from doped β-TCPs. These cements demonstrated high cytocompatibility with mesenchymal stromal cells (>89% viability) and significantly enhanced osteogenic differentiation with antimicrobial activity against common pathogens (S. aureus, E. coli, P. aeruginosa). Furthermore, incorporation of these phosphates as fillers into PMMA bone cement resulted in a homogeneous particle distribution with reduced agglomeration compared to undoped β-TCPs, achieving clinically relevant radiopacity values (913 ± 22.4 HU for Dy-doped sample). Post-mortem studies by the CT method were performed on the vertebrae with PMMA–phosphate composites and brushite cements. It was shown that brushite cement in ovine lumbar vertebrae defects exhibited the highest radiopacity (1450–1550 ± 25 HU). The findings establish rare-earth-doped β-TCP as a unified multifunctional precursor that imparts bioactivity, the ability to support in vitro mineralization, antimicrobial properties, and enhanced radiopacity to thin films, phosphate cements, and polymer composite materials. Full article
(This article belongs to the Special Issue Films and Coatings with Biomedical Applications)
Show Figures

Figure 1

15 pages, 3071 KB  
Article
Green-Synthesized TiO2 Nanoparticles Improve Mechanical Performance of Glass Ionomer Cements
by Nevra Karamüftüoğlu, Süha Kuşçu, İpek Kuşçu and Nesrin Korkmaz
Polymers 2026, 18(2), 295; https://doi.org/10.3390/polym18020295 - 22 Jan 2026
Cited by 1 | Viewed by 1033
Abstract
Glass ionomer cements (GICs) are widely used in restorative and luting dentistry due to their fluoride release and chemical adhesion to dental tissues; however, their limited mechanical strength necessitates reinforcement strategies. The objective of this study was to investigate the effects of hemp-derived, [...] Read more.
Glass ionomer cements (GICs) are widely used in restorative and luting dentistry due to their fluoride release and chemical adhesion to dental tissues; however, their limited mechanical strength necessitates reinforcement strategies. The objective of this study was to investigate the effects of hemp-derived, green-synthesized titanium dioxide (TiO2) nanoparticles on the surface and mechanical properties of two commercially available GICs with different clinical indications. TiO2 nanoparticles were synthesized using Cannabis sativa leaf extract via a biogenic reduction method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX), confirming anatase-phase crystallinity, spherical morphology, and nanoscale particle size (28–49 nm). The nanoparticles were incorporated into Ketac™ Molar Easymix (restorative) and Ketac™ Cem Radiopaque (luting) GICs at 1%, 3%, and 5% (w/w), with nanoparticle-free formulations serving as controls (n = 10). Surface roughness, Vickers microhardness, and flexural strength were evaluated. Surface roughness increased in a concentration-dependent manner in both materials, with the highest values observed at 5% TiO2 incorporation. In Ketac™ Molar Easymix, 1% and 3% TiO2 significantly enhanced flexural strength and microhardness, whereas 5% resulted in reduced performance, consistent with SEM-observed nanoparticle agglomeration. In contrast, Ketac™ Cem Radiopaque exhibited no significant changes in flexural strength, although maximum microhardness values were recorded at 1% TiO2 concentration. These findings demonstrate that low concentrations of hemp-derived TiO2 nanoparticles can effectively reinforce restorative GICs and highlight the potential of green nanotechnology as a sustainable approach for improving dental biomaterials. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Graphical abstract

18 pages, 8164 KB  
Article
Development and Characterization of a Biodegradable Radiopaque PLA/Gd2O3 Filament for Bone-Equivalent Phantom Produced via Fused Filament Fabrication
by Özkan Özmen and Sena Dursun
Polymers 2025, 17(23), 3193; https://doi.org/10.3390/polym17233193 - 30 Nov 2025
Cited by 1 | Viewed by 1245
Abstract
Additive manufacturing (AM) has rapidly evolved due to its design flexibility, ability to enable personalized fabrication, and reduced material waste. In the medical field, fused filament fabrication (FFF) facilitates the production of individualized anatomical models for surgical preparation, education, medical imaging, and calibration. [...] Read more.
Additive manufacturing (AM) has rapidly evolved due to its design flexibility, ability to enable personalized fabrication, and reduced material waste. In the medical field, fused filament fabrication (FFF) facilitates the production of individualized anatomical models for surgical preparation, education, medical imaging, and calibration. However, the lack of filaments with X-ray attenuation similar to that of biological hard tissues limits their use in radiological imaging. To address this limitation, a radiopaque filament was developed by incorporating gadolinium oxide (Gd2O3) into a biodegradable poly(lactic acid) (PLA) matrix at 1, 3, and 5 wt.%. Thermal and rheological properties were characterized using differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and melt flow index (MFI) analyses, revealing minor variations that did not affect printability under standard FFF conditions (200 °C nozzle, 60 °C build plate, 0.12 mm layer height). Microstructural analysis via field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDX), elemental mapping, and micro-computed tomography (micro-CT) confirmed homogeneous Gd2O3 dispersion without nozzle blockage. Radiopacity was evaluated using gyroid infill cubes, and increasing Gd2O3 content enhanced X-ray attenuation, with 3 wt.% Gd2O3 reaching Hounsfield Unit (HU) values comparable to cortical bone. Finally, the L1 vertebra phantom fabricated from the 3 wt.% Gd2O3 filament exhibited mean HU values of approximately +200 to +250 HU at 50% infill density (trabecular bone region) and around +1000 HU at 100% infill density (cortical bone region), demonstrating the filament’s potential for producing cost-effective, radiopaque, and biodegradable phantoms for computed tomography (CT) imaging. Full article
(This article belongs to the Special Issue Latest Progress in the Additive Manufacturing of Polymeric Materials)
Show Figures

Figure 1

15 pages, 1100 KB  
Article
Assessment of CA4+ Impact on Mechanical Properties of Articular Cartilage
by Matteo Berni, Simone Fantoni, Roberta Fognani, Paolo Cardarelli, Fabio Baruffaldi and Massimiliano Baleani
Materials 2025, 18(13), 2943; https://doi.org/10.3390/ma18132943 - 21 Jun 2025
Cited by 1 | Viewed by 4146
Abstract
X-ray imaging of articular cartilage could be a breakthrough for the early diagnosis of tissue degeneration. This approach relies on radiopaque contrast agents to enhance the visualization of soft tissues. The potential impact of contrast agents on the mechanical response of articular cartilage [...] Read more.
X-ray imaging of articular cartilage could be a breakthrough for the early diagnosis of tissue degeneration. This approach relies on radiopaque contrast agents to enhance the visualization of soft tissues. The potential impact of contrast agents on the mechanical response of articular cartilage should be considered in the frame of both clinical and research applications. Attention has been drawn to a solution containing molecules with six iodine atoms and four positive charges (CA4+), which has been shown to improve the X-ray visibility of articular cartilage. This study aimed to determine the effects of a CA4+ solution on tissues’ mechanical properties. An experimental pipeline based on indentation tests was applied to paired samples of articular cartilage before and after the immersion in either CA4+ or phosphate-buffered saline solution, maintained at a temperature of 22 ± 2 °C, for 22 h to determine the differences in instantaneous, viscous, and equilibrium responses between the articular cartilage of the two groups. The 22 h immersion of articular cartilage in either CA4+ or phosphate-buffered saline solution had a significant detrimental effect on the overall response, including the instantaneous, viscous, and equilibrium responses, of the articular cartilage. However, this detrimental effect was greater with exposure to the CA4+ solution. Specifically, the articular cartilage was found to be less stiff in both the instantaneous response (approximately −25%) and the equilibrium response (approximately −38%). The softening effect could be attributable to an alteration of the interaction between the proteoglycans of articular cartilage, induced by the positive charges within the CA4+ contrast agent. Further investigations are needed to elucidate whether this hypothesized mechanism is reversible. Full article
(This article belongs to the Special Issue State of the Art of Materials Science and Engineering in Italy)
Show Figures

Figure 1

20 pages, 6268 KB  
Article
Theoretical Investigation of Photon Interaction and X-Ray Imaging Performance of PEEK-Based Composites for Medical Implants
by Hanan Akhdar
Polymers 2025, 17(7), 996; https://doi.org/10.3390/polym17070996 - 7 Apr 2025
Cited by 8 | Viewed by 1652
Abstract
Polyetheretherketone (PEEK) is a high-performance, biocompatible polymer with remarkable mechanical properties, making it a promising candidate for medical implants. However, its intrinsic radiolucency poses a challenge for post-operative imaging. This study investigates the photon shielding capabilities and X-ray imaging qualities of pure PEEK [...] Read more.
Polyetheretherketone (PEEK) is a high-performance, biocompatible polymer with remarkable mechanical properties, making it a promising candidate for medical implants. However, its intrinsic radiolucency poses a challenge for post-operative imaging. This study investigates the photon shielding capabilities and X-ray imaging qualities of pure PEEK and its composites with barium sulfate (BaSO4), tantalum (Ta), bismuth oxide (Bi2O3), and hydroxyapatite (HA). The Monte Carlo-based Geant4 toolkit and the EpiXS application were used to evaluate key photon interaction parameters, including mass attenuation coefficients, effective atomic number (Zeff), and effective electron density (Neff), as well as the imaging performance metrics such as energy deposition and signal-to-noise ratio (SNR). Results indicate that high atomic number composites significantly enhance PEEK’s photon attenuation and imaging contrast. PEEK-Bi2O3 exhibited the highest attenuation coefficients and energy deposition, making it the most effective X-ray shielding material. PEEK-Ta provided a balanced performance with enhanced shielding and lower secondary radiation effects, making it suitable for applications requiring both radiopacity and imaging stability. PEEK-BaSO4 moderately improved attenuation while maintaining a lower density, offering a trade-off between radiopacity and mechanical properties. Conversely, PEEK-HA demonstrated minimal enhancement in photon attenuation, limiting its effectiveness for radiographic applications. The findings suggest that incorporating high atomic number elements into PEEK significantly enhances its suitability for radiopaque medical implants, allowing for improved post-operative monitoring. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

17 pages, 4021 KB  
Article
Fabrication of Radiopaque, Drug-Loaded Resorbable Polymer for Medical Device Development
by Sophie T. Melancon, Erin Marie San Valentin, Dominic Karl M. Bolinas, Marvin R. Bernardino, Archana Mishra, Gino Canlas, Gouthami Chintalapani, Megan C. Jacobsen, Allan John R. Barcena and Steven Y. Huang
Polymers 2025, 17(6), 716; https://doi.org/10.3390/polym17060716 - 7 Mar 2025
Cited by 6 | Viewed by 2534
Abstract
Resorbable medical devices provide temporary functionality before degrading into safe byproducts. One application is absorbable inferior vena cava filters (IVCFs), which prevent pulmonary embolism in high-risk patients with contraindications to anticoagulants. However, current absorbable IVCFs are limited by radiolucency and local clot formation [...] Read more.
Resorbable medical devices provide temporary functionality before degrading into safe byproducts. One application is absorbable inferior vena cava filters (IVCFs), which prevent pulmonary embolism in high-risk patients with contraindications to anticoagulants. However, current absorbable IVCFs are limited by radiolucency and local clot formation risks. This study aimed to develop radiopaque, drug-loaded resorbable IVCFs with enhanced imaging and therapeutic capabilities. Poly-p-dioxanone (PPDO) sutures were infused with gadolinium nanoparticles (GdNPs) and dipyridamole (DPA), an anti-thrombotic agent. GdNPs were synthesized with an average diameter of 35.76 ± 3.71 nm. Gd content was 371 ± 1.6 mg/g (PPDO-Gd) and 280 ± 0.3 mg/g (PPDO-Gd + DPA), while the DPA content was 18.20 ± 5.38 mg/g (PPDO-DPA) and 12.91 ± 0.83 mg/g (PPDO-Gd + DPA). Suture thickness (0.39–0.49 cm, p = 0.0143) and melting temperature (103.61–105.90, p = 0.0002) statistically differed among the different groups, while load-at-break did not (4.39–5.38, p = 0.2367). Although suture thickness and melting temperatures differed significantly, load-at-break was preserved and did not alter the mechanical and degradation properties of the various IVCFs. Micro-computed tomography revealed enhanced radiopacity for Gd-containing IVCFs (2713 ± 105 HU for PPDO-Gd, 1516 ± 281 HU for PPDO-Gd + DPA). Radiopacity decreased gradually over 10–12 weeks. Clot-trapping efficacy was maintained, and no hemolysis or cellular toxicity was observed. In conclusion, the GdNP- and DPA-infused PPDO IVCFs demonstrated improved radiopacity, anti-thrombotic potential, and compatibility with routine imaging, without compromising mechanical strength or safety. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

22 pages, 3075 KB  
Article
Co-Optimization of Mechanical Properties and Radiopacity Through Radiopaque Filler Incorporation for Medical Tubing Applications
by Alan Nugent, Joseph Molloy, Maurice Kelly and Declan Mary Colbert
Polymers 2024, 16(22), 3220; https://doi.org/10.3390/polym16223220 - 20 Nov 2024
Cited by 1 | Viewed by 3679
Abstract
Medical tubing, particularly cardiovascular tubing, is a critical area of research where continuous improvements are necessary to advance medical devices and improve patient care. While polymers are fundamental for these applications, on their own they present several limitations such as insufficient X-ray contrasting [...] Read more.
Medical tubing, particularly cardiovascular tubing, is a critical area of research where continuous improvements are necessary to advance medical devices and improve patient care. While polymers are fundamental for these applications, on their own they present several limitations such as insufficient X-ray contrasting capabilities. As such, polymer composites utilizing radiopaque fillers are a necessity for this application. For medical tubing in vivo, radiopacity is a crucial parameter that virgin polymers alone fall short in achieving due to limited X-ray absorption. To address this shortcoming, inorganic radiopaque fillers such as barium sulphate (BaSO4) and bismuth oxychloride (BiOCl) are incorporated into polymer matrices to increase the X-ray contrast of the manufactured tubing. It is also known, however, that the incorporation of these fillers can affect the mechanical, physical, and thermal properties of the finished product. This research evaluated the impact of incorporating the two aforementioned fillers into Pebax® 6333 SA01 MED at three different loading levels (10, 20, and 30 wt.%) on the physical, thermal, and mechanical properties of the composite. Composites were prepared by twin screw extrusion and injection molding followed by characterization of the mechanical (tensile, impact, and flexural), thermal (DSC), rheological (MFI), and physical (density and ash content) properties. The performed analysis shows that BiOCl enhanced the aesthetic properties, increased stiffness, and maintained flexibility while having minimal impact on the tensile and impact properties. When comparing BiOCl to BaSO4-filled composites, it was clear that depending on the application of the polymer composite, BiOCl may provide more desirable properties. The study highlights the importance of optimizing filler concentration and processing conditions to achieve desired composite properties for specific medical applications. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

20 pages, 5016 KB  
Article
Radiopaque Polyurethanes Containing Barium Sulfate: A Survey on Thermal, Rheological, Physical, and Structural Properties
by Heitor Luiz Ornaghi Júnior, Benoit Duchemin, Sanae Azzaye, Márcio Ronaldo Farias Soares, Bárbara Schneider and Carlos Henrique Romoaldo
Polymers 2024, 16(21), 3086; https://doi.org/10.3390/polym16213086 - 31 Oct 2024
Cited by 4 | Viewed by 3255
Abstract
Radiopaque polyurethanes are extensively used in biomedical fields owing to their favorable balance of properties. This research aims to investigate the influence of particle concentration on various properties, including rheological, radiopacity, structural, thermal, and mechanical attributes, with a thorough analysis. The findings are [...] Read more.
Radiopaque polyurethanes are extensively used in biomedical fields owing to their favorable balance of properties. This research aims to investigate the influence of particle concentration on various properties, including rheological, radiopacity, structural, thermal, and mechanical attributes, with a thorough analysis. The findings are benchmarked against a commercial product (PL 8500 A) that contains 10% weight barium sulfate. Two more thermoplastic polyurethanes (TPU) were formulated with two different concentrations of barium sulfate (10 wt.% and 20 wt.%) and compared to the commercially available product. FTIR demonstrated similar absorption bands among all samples, indicating that the fabrication method did not impact the TPU matrix. DSC indicated a predominantly amorphous structure for PL 8500 A compared to the other samples, while the kinetic degradation was more influenced by the higher barium sulfate content. The rheological analysis showed a decrease in the complex viscosity and storage modulus with the radiopacifier and an increase in the radiopacity, as demonstrated by the X-radiography. X-ray microtomography showed a more spherical particle format with a heterogeneous particle structure for PL 8500 A compared to the other polyurethanes. These findings enhance the comprehension of the structure–property relationships inherent in these materials and facilitate the development of customized materials for targeted applications. Full article
Show Figures

Figure 1

28 pages, 14294 KB  
Review
A Short Review on Radiopaque Polyurethanes in Medicine: Physical Principles, Effect of Nanoparticles, Processing, Properties, and Applications
by Julia Garavatti and Heitor Luiz Ornaghi Jr.
J. Compos. Sci. 2024, 8(10), 409; https://doi.org/10.3390/jcs8100409 - 5 Oct 2024
Cited by 5 | Viewed by 4404
Abstract
Polyurethanes are used in a wide range of biomedical applications due to their variety of physical–chemical, mechanical, and structural properties, and biotic and abiotic degradation. They are widely used in bio-imaging procedures when metallic-based filler particles are incorporated, making the final product radiopaque. [...] Read more.
Polyurethanes are used in a wide range of biomedical applications due to their variety of physical–chemical, mechanical, and structural properties, and biotic and abiotic degradation. They are widely used in bio-imaging procedures when metallic-based filler particles are incorporated, making the final product radiopaque. It would be advantageous, however, if polyurethanes with intrinsic radiopacity could be produced in their synthesis, avoiding a series of disadvantages in the processing and final product and also presenting potential antimicrobial activities. This review’s objective was to study the radiopacifying characteristics of nanoparticles, the physical principles of radiopacity, and the variety of medical applications of polyurethanes with nanoparticles. It was found in this study that the synthetization of radiopaque polyurethanes is not only possible but the efficiency of synthetization was improved when using atoms with high electron density as part of the backbone or when grafted, making them great multipurpose materials. Full article
Show Figures

Figure 1

17 pages, 3227 KB  
Article
Development of Robust PEBAX-Based Angiographic Catheter: Design and In Vitro Study
by Hafsa Inam, Murtaza Najabat Ali, Ibraheem Raza Jameel, Dil Awaiz and Zunaira Qureshi
Materials 2024, 17(17), 4248; https://doi.org/10.3390/ma17174248 - 28 Aug 2024
Cited by 3 | Viewed by 4078
Abstract
Background: Keeping in mind the unceasingly escalating prevalence of coronary disease worldwide, the mortality rate is also expected to rise with a staggering increase in healthcare costs. Angiography is the gold standard for diagnosing these blockages that trigger these diseases. Amides and urethanes [...] Read more.
Background: Keeping in mind the unceasingly escalating prevalence of coronary disease worldwide, the mortality rate is also expected to rise with a staggering increase in healthcare costs. Angiography is the gold standard for diagnosing these blockages that trigger these diseases. Amides and urethanes are the common catheter construction material used for angiography. However, the experimental evidence verifying the use of PEBAX® and comparing its performance with that of commercially available catheters for angiography is not published despite it being well recognized for its excellent flexural modulus, mechanical properties, and biocompatibility and its potential to reduce the incidence of vascular spasm during intravascular diagnostic and interventional procedures. Therefore, the aim of this study was to develop a PEBAX®-based angiographic catheter and evaluate its performance in comparison with three commercially available nylon- and polyurethane-based angiographic catheters. Methodology: A PEBAX®-based angiographic catheter was developed for this purpose. This study analyzes and reports the performance and behavior of PEBAX®-, nylon-, and polyurethane-based catheters. The catheter’s performance and arterial forces’ endurance nature were mapped out by evaluating pushability (advancement force) and selective bench tests outlined in the applicable regulatory standard. Conclusions: The PEBAX®-based catheter exhibited the least bond-flexural rigidity (180.4 g), which was approximately one-third of that shown by all six French catheters and which exhibited the least advancement force (510.4 g), which was approximately 50% less than that of the nylon- and polyurethane-based catheters when traversing through the mock arterial system. Bench testing was carried out as per the applicable regulatory standard; the differences obtained between individual catheters were discussed in detail. Based on this extensive in vitro assessment, it was concluded that the PEBAX®-based catheters outperformed the nylon- and polyurethane-based catheters, exhibiting an exceptionally minimal advancement force of 510.4 g. This leads to the inference that this catheter can inject more radiopaque material (because of the enhanced flow rate) to the coronary arteries and can play a significant role in minimizing vascular spasms during a diagnostic procedure. Full article
Show Figures

Figure 1

12 pages, 3346 KB  
Article
Production of Composite Zinc Oxide–Polylactic Acid Radiopaque Filaments for Fused Deposition Modeling: First Stage of a Feasibility Study
by Francesca Cherubini, Nicole Riberti, Anna Maria Schiavone, Fabrizio Davì, Michele Furlani, Alessandra Giuliani, Gianni Barucca, Maria Cristina Cassani, Daniele Rinaldi and Luigi Montalto
Materials 2024, 17(12), 2892; https://doi.org/10.3390/ma17122892 - 13 Jun 2024
Cited by 3 | Viewed by 2125
Abstract
Three-dimensional printing technologies are becoming increasingly attractive for their versatility; the geometrical customizability and manageability of the final product properties are the key points. This work aims to assess the feasibility of producing radiopaque filaments for fused deposition modeling (FDM), a 3D printing [...] Read more.
Three-dimensional printing technologies are becoming increasingly attractive for their versatility; the geometrical customizability and manageability of the final product properties are the key points. This work aims to assess the feasibility of producing radiopaque filaments for fused deposition modeling (FDM), a 3D printing technology, starting with zinc oxide (ZnO) and polylactic acid (PLA) as the raw materials. Indeed, ZnO and PLA are promising materials due to their non-toxic and biocompatible nature. Pellets of PLA and ZnO in the form of nanoparticles were mixed together using ethanol; this homogenous mixture was processed by a commercial extruder, optimizing the process parameters for obtaining mechanically stable samples. Scanning electron microscopy analyses were used to assess, in the extruded samples, the homogenous distribution of the ZnO in the PLA matrix. Moreover, X-ray microtomography revealed a certain homogenous radiopacity; this imaging technique also confirmed the correct distribution of the ZnO in the PLA matrix. Thus, our tests showed that mechanically stable radiopaque filaments, ready for FDM systems, were obtained by homogenously loading the PLA with a maximum ZnO content of 6.5% wt. (nominal). This study produced multiple outcomes. We demonstrated the feasibility of producing radiopaque filaments for additive manufacturing using safe materials. Moreover, each phase of the process is cost-effective and green-oriented; in fact, the homogenous mixture of PLA and ZnO requires only a small amount of ethanol, which evaporates in minutes without any temperature adjustment. Finally, both the extruding and the FDM technologies are the most accessible systems for the additive manufacturing commercial apparatuses. Full article
(This article belongs to the Special Issue Design and Application of Additive Manufacturing: Volume II)
Show Figures

Figure 1

13 pages, 6510 KB  
Article
Using Functionalized Micron-Sized Glass Fibres for the Synergistic Effect of Glass Ionomer on Luting Material
by Hanan Alsunbul, Aftab Ahmed Khan, Yasser M. Alqahtani, Saeed Awod bin Hassan, Waleed Asiri, Selma Saadaldin, Rasha Alharthi and Alhanoof Aldegheishem
J. Funct. Biomater. 2023, 14(11), 550; https://doi.org/10.3390/jfb14110550 - 16 Nov 2023
Cited by 10 | Viewed by 2423
Abstract
This laboratory experiment was conducted with the objective of augmenting the mechanical properties of glass ionomer cement (GIC) via altering the composition of GIC luting powder through the introduction of micron-sized silanized glass fibres (GFs). Experimental GICs were prepared through the addition of [...] Read more.
This laboratory experiment was conducted with the objective of augmenting the mechanical properties of glass ionomer cement (GIC) via altering the composition of GIC luting powder through the introduction of micron-sized silanized glass fibres (GFs). Experimental GICs were prepared through the addition of two concentrations of GFs (0.5% and 1.0% by weight) to the powder of commercially available GIC luting materials. The effect of GF in set GIC was internally evaluated using micro-CT while the mechanical attributes such as nano hardness (nH), elastic modulus (EM), compressive strength (CS), and diametral tensile strength (DTS) were gauged. Additionally, the physical properties such as water solubility and sorption, contact angle (CA), and film thickness were evaluated. Reinforced Ketac Cem Radiopaque (KCR) GIC with 0.5 wt.% GF achieved improved nH, EM, CS, and DTS without affecting the film thickness, CA or internal porosity of the set GIC cement. In contrast, both GF-GIC formulations of Medicem (MC) GIC showed the detrimental effect of the GF incorporation. Reinforcing KCR GIC with 0.5 wt.% silanized GFs could improve the physical and mechanical attributes of luting material. Silanized GF, with optimal concentration within the GIC powder, can be used as a functional additive in KCR GIC with promising results. Full article
Show Figures

Figure 1

13 pages, 3823 KB  
Article
Utilizing an Oxidized Biopolymer to Enhance the Bonding of Glass Ionomer Luting Cement Particles for Improved Physical and Mechanical Properties
by Hanan Alsunbul, Aftab Ahmed Khan, Merry Angelyn Tan De Vera, Leonel S. J. Bautista and Ravish Javed
Biomimetics 2023, 8(4), 347; https://doi.org/10.3390/biomimetics8040347 - 5 Aug 2023
Cited by 10 | Viewed by 2583
Abstract
This study aimed to determine the reinforcing effect of two weight ratios of Gum Arabic (GA) natural biopolymer, i.e., 0.5% and 1.0% in the powdered composition of glass ionomer luting cement. GA powder was oxidized and GA-reinforced GIC in 0.5 and 1.0 wt.% [...] Read more.
This study aimed to determine the reinforcing effect of two weight ratios of Gum Arabic (GA) natural biopolymer, i.e., 0.5% and 1.0% in the powdered composition of glass ionomer luting cement. GA powder was oxidized and GA-reinforced GIC in 0.5 and 1.0 wt.% formulations were prepared in rectangular bars using two commercially available GIC luting materials (Medicem and Ketac Cem Radiopaque). The control groups of both materials were prepared as such. The effect of reinforcement was evaluated in terms of microhardness, flexural strength (FS), fracture toughness (FT), and tensile strength (TS). The internal porosity and water contact angle formation on the study samples were also evaluated. Film thickness was measured to gauge the effect of micron-sized GA powder in GA–GIC composite. Paired sample t-tests were conducted to analyze data for statistical significance (p < 0.05). The experimental groups of both materials containing 0.5 wt.% GA–GIC significantly improved FS, FT, and TS compared to their respective control groups. However, the microhardness significantly decreased in experimental groups of both cements compared to their respective control groups. The addition of GA powder did not cause a significant increase in film thickness and the water contact angle of both 0.5 and 1.0 wt.% GA–GIC formulations were less than 90o. Interestingly, the internal porosity of 0.5 wt.% GA–GIC formulations in both materials were observed less compared to their respective control groups. The significantly higher mechanical properties and low porosity in 0.5 wt.% GA–GIC formulations compared to their respective control group indicate that reinforcing GA powder with 0.5 wt.% in GIC might be promising in enhancing the mechanical properties of GIC luting materials. Full article
(This article belongs to the Special Issue Dentistry and Cranio Facial District: The Role of Biomimetics)
Show Figures

Figure 1

18 pages, 9257 KB  
Article
Novel Bone Void Filling Cement Compositions Based on Shell Nacre and Siloxane Methacrylate Resin: Development and Characterization
by Bridget Jeyatha Wilson and Lizymol Philipose Pampadykandathil
Bioengineering 2023, 10(7), 752; https://doi.org/10.3390/bioengineering10070752 - 23 Jun 2023
Cited by 1 | Viewed by 3207
Abstract
Shell nacre from Pinctada species has been extensively researched for managing bone defects. However, there is a gap in the research regarding using shell nacre powder as a cement with improved biological and physicochemical properties. To address this, bone void filling cement was [...] Read more.
Shell nacre from Pinctada species has been extensively researched for managing bone defects. However, there is a gap in the research regarding using shell nacre powder as a cement with improved biological and physicochemical properties. To address this, bone void filling cement was formulated by incorporating shell nacre powder and an organically modified ceramic resin (ormocer). The shell nacre powder was specifically processed from the shells of Pinctada fucata and analysed using thermogravimetric analysis (TGA), X-ray diffraction spectroscopy, Fourier transform infrared (FTIR), and Raman spectroscopy, confirming the presence of organic constituents and inorganic aragonite. Trace element analysis confirmed the eligibility of shell nacre powder for biomedical applications. Next, the ormocer SNLSM2 was synthesized through a modified sol–gel method. FTIR, Raman, TGA, and transmission electron microscopy studies revealed the presence of a ladder-structured siloxane backbone and methacrylate side chain. To develop chemical curable composite shell nacre cement (SNC), different amounts of shell nacre (24%, 48%, and 72%) were added to the SNLSM2 resin, and the impact on the physicochemical properties of the cement was studied. Among the compositions, SNC 72 exhibited significantly lower linear polymerization shrinkage (0.4%) and higher compressive (>100 MPa) and flexural strength (>35 MPa). SNC 72 was radiopaque, and the exotherm generated during the cement curing was minimal. Cytotoxicity studies with L929 cells revealed the non-cytotoxic nature of the cement. Overall, the findings of this study prove that the shell nacre cement is a promising candidate for managing bone voids. Full article
Show Figures

Graphical abstract

Back to TopTop