Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (19)

Search Parameters:
Keywords = portable on-line measuring devices

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 11548 KiB  
Article
On-Site Detection of Ca and Mg in Surface Water Using Portable Laser-Induced Breakdown Spectroscopy
by Yuanxin Wan, Shixiang Ma, Peichao Zheng, Xiande Zhao, Zhen Xing, Leizi Jiao, Hongwu Tian and Daming Dong
Chemosensors 2025, 13(1), 16; https://doi.org/10.3390/chemosensors13010016 - 14 Jan 2025
Viewed by 1038
Abstract
Ca and Mg are key constituents in surface water that are essential nutrients and vital indicators of water hardness. Rapid on-site measurement of Ca and Mg concentrations in surface water is important. However, traditional laboratory detection methods are complex and time-consuming, and on-site [...] Read more.
Ca and Mg are key constituents in surface water that are essential nutrients and vital indicators of water hardness. Rapid on-site measurement of Ca and Mg concentrations in surface water is important. However, traditional laboratory detection methods are complex and time-consuming, and on-site detection is difficult. In this study, a portable surface water detection method was developed using laser-induced breakdown spectroscopy with a miniaturized spectrometer LIBS and a liquid jet device for sample introduction. The device enables the rapid online in situ measurement of elemental concentrations in the water. The limits of detection for the rapid on-site detection of Ca and Mg in surface water were 11.58 and 2.57 mg/L, respectively. We applied this method to assess the concentrations of Ca and Mg in authentic water samples collected from rivers and ponds. The recovery rates for Ca and Mg were 90.83–101.74% and 93.43–108.74%, respectively. This method is suitable for rapid, on-site, and highly sensitive monitoring of Ca and Mg concentrations in the environment. Full article
(This article belongs to the Special Issue Application of Laser-Induced Breakdown Spectroscopy, 2nd Edition)
Show Figures

Figure 1

24 pages, 701 KiB  
Systematic Review
Applying Spectroscopies, Imaging Analyses, and Other Non-Destructive Techniques to Olives and Extra Virgin Olive Oil: A Systematic Review of Current Knowledge and Future Applications
by Alessio Cappelli, Sirio Cividino, Veronica Redaelli, Gianluca Tripodi, Gilda Aiello, Salvatore Velotto and Mauro Zaninelli
Agriculture 2024, 14(7), 1160; https://doi.org/10.3390/agriculture14071160 - 16 Jul 2024
Cited by 6 | Viewed by 1799
Abstract
Given its huge economic, nutritional, and social value, extra virgin olive oil (EVOO) is an essential food. This flagship product of the countries bordering the Mediterranean basin is one of the most frauded products worldwide. Although traditional chemical analyses have demonstrated to be [...] Read more.
Given its huge economic, nutritional, and social value, extra virgin olive oil (EVOO) is an essential food. This flagship product of the countries bordering the Mediterranean basin is one of the most frauded products worldwide. Although traditional chemical analyses have demonstrated to be reliable tools for olive drupes and EVOO quality assessment, they present several drawbacks; the urgent need for fast and non-destructive techniques thus motivated this review. Given the lack of comprehensive reviews in the literature, our first aim was to summarize the current knowledge regarding applying spectroscopies, imaging analyses, and other non-destructive techniques to olives and EVOO. The second aim was to highlight the most innovative and futuristic applications and outline the future research prospects within this strategic production chain. With respect to olive drupes, the most interesting results were obtained using RGB imaging and NIR spectroscopy, particularly using portable NIR devices and specific digital cameras for in-field or in-mill monitoring. Nevertheless, it is important to highlight that RGB imaging and NIR spectroscopy need to be integrated with flesh hardness measurements, given the higher reliability of this parameter compared to olive skin color. Finally, with respect to EVOO, although several useful applications of visible imagining, UV–Visible, NIR, and Mid-Infrared spectroscopies have been found, the online monitoring of EVOO quality using NIR spectroscopy strikes us as being the most interesting technique for improving the EVOO production chain in the near future. Full article
(This article belongs to the Section Agricultural Product Quality and Safety)
Show Figures

Figure 1

14 pages, 1657 KiB  
Review
Shoulder Proprioception: A Review
by Jake A. Fox, Lauren Luther, Eden Epner and Lance LeClere
J. Clin. Med. 2024, 13(7), 2077; https://doi.org/10.3390/jcm13072077 - 3 Apr 2024
Cited by 7 | Viewed by 4744
Abstract
The purpose of this review is to provide a comprehensive resource for shoulder proprioception assessment and its integration into clinical decision making as well as targeted rehabilitation protocols. Data for this review were acquired from peer-reviewed articles from computerized online databases, namely PubMed [...] Read more.
The purpose of this review is to provide a comprehensive resource for shoulder proprioception assessment and its integration into clinical decision making as well as targeted rehabilitation protocols. Data for this review were acquired from peer-reviewed articles from computerized online databases, namely PubMed and Medline, published between 1906 and 2021. The development of digital/smart phone goniometers can improve shoulder joint range of motion (ROM) measurements and demonstrate comparable measurement accuracy to the universal standard goniometer. The inclinometer offers a portable and cost-effective method for measuring shoulder joint angles and arcs of motion in the vertical plane. Two types of dynamometers, the computerized isokinetic machine and the handheld hydraulic dynamometer, are reliable tools for objective shoulder rotator cuff strength assessment. Motion analysis systems are highly advanced modalities that create three-dimensional models of motion arcs using a series of cameras and reflective beads, offering unparalleled precision in shoulder proprioception measurement; however, they require time-consuming calibration and skilled operators. Advancements in wearable devices and compact mobile technology such as iPhone applications may make three-dimensional motion analysis more affordable and practical for outpatient settings in the future. The complex interplay between proprioception and shoulder dysfunction is not fully understood; however, shoulder proprioception can likely both contribute to and be caused by shoulder pathology. In patients with rotator cuff tears, glenohumeral osteoarthritis, and shoulder instability, clinicians can track proprioception to understand a patient’s disease progression or response to treatment. Finally, rehabilitation programs targeting shoulder proprioception have shown promising initial results in restoring function and returning athletes to play. Full article
(This article belongs to the Special Issue Advances in Shoulder Surgery: Current Trends and Future Directions)
Show Figures

Figure 1

20 pages, 8232 KiB  
Article
Rapid Geometric Evaluation of Transportation Infrastructure Based on a Proposed Low-Cost Portable Mobile Laser Scanning System
by Haochen Wang and Dongming Feng
Sensors 2024, 24(2), 425; https://doi.org/10.3390/s24020425 - 10 Jan 2024
Cited by 3 | Viewed by 1367
Abstract
Efficient geometric evaluation of roads and tunnels is crucial to traffic management, especially in post-disaster situations. This paper reports on a study of the geometric feature detection method based on multi-sensor mobile laser scanning (MLS) system data. A portable, low-cost system that can [...] Read more.
Efficient geometric evaluation of roads and tunnels is crucial to traffic management, especially in post-disaster situations. This paper reports on a study of the geometric feature detection method based on multi-sensor mobile laser scanning (MLS) system data. A portable, low-cost system that can be mounted on vehicles and utilizes integrated laser scanning devices was developed. Coordinate systems and timestamps from numerous devices were merged to create 3D point clouds of objects being measured. Feature points reflecting the geometric information of measuring objects were retrieved based on changes in the point cloud’s shape, which contributed to measuring the road width, vertical clearance, and tunnel cross section. Self-developed software was used to conduct the measuring procedure, and a real-time online visualized platform was designed to reconstruct 3D models of the measured objects, forming a 3D digital map carrying the obtained geometric information. Finally, a case study was carried out. The measurement results of several representative nodes are discussed here, verifying the robustness of the proposed system. In addition, the main sources of interference are also discussed. Full article
(This article belongs to the Special Issue LiDAR Sensors Applied in Intelligent Transportation Systems)
Show Figures

Figure 1

13 pages, 2302 KiB  
Article
Association between Skin Carotenoid Score Measured with Veggie Meter® and Adherence to the Mediterranean Diet among Adolescents from Southern Italy
by Giovanna Caparello, Giovanni Dongionny Groccia, Fabrizio Ceraudo, Mirko Cesario, Renzo Bonofiglio, Giuseppina Augimeri and Daniela Bonofiglio
Nutrients 2023, 15(23), 4920; https://doi.org/10.3390/nu15234920 - 25 Nov 2023
Cited by 7 | Viewed by 2638
Abstract
The Veggie Meter® (Longevity Link Corporation, Salt Lake City, UT, USA), is a new portable device for the non-invasive and rapid detection of skin carotenoid content, which represents an acceptable biomarker for the evaluation of fruit and vegetable (FV) intake. FVs are [...] Read more.
The Veggie Meter® (Longevity Link Corporation, Salt Lake City, UT, USA), is a new portable device for the non-invasive and rapid detection of skin carotenoid content, which represents an acceptable biomarker for the evaluation of fruit and vegetable (FV) intake. FVs are important components of a healthy diet, including the Mediterranean Diet (MD), which is a plant-based dietary pattern. Here, we evaluated the adherence to the MD via the administration of two online food questionnaires, and we measured the skin carotenoid content using the Veggie Meter® in a cohort of 498 healthy adolescents (233 males and 265 females) from Southern Italy. Using KIDMED and the MD Pyramid tests to assess the adherence to the MD, we found an average adherence (5.43 ± 2.57 and 7.20 ± 1.93, respectively) to the MD in our sample population. Moreover, we observed that the skin carotenoid score was 364.75 ± 98.29, which was within the normal range and inversely related to the BMI (r = −0.1461, p = 0.0011). Similar results were observed when the population was categorized by sex. Interestingly, we demonstrated, for the first time, a positive correlation between the carotenoid score and the adherence to the MD assessed using both the KIDMED and MD Pyramid tests in the total population (r = −0.2926, p < 0.0001 and r = −0.1882, p < 0.0001, respectively). The same direct correlation was found in adolescents according to their sex. Our findings highlight the potential of the Veggie Meter® as a feasible and promising tool for evaluating adherence to the MD and, ultimately, to promote healthy eating habits among adolescents. Full article
Show Figures

Graphical abstract

17 pages, 4864 KiB  
Article
Inertial Measurement Unit-Based Real-Time Adaptive Algorithm for Human Walking Pattern and Gait Event Detection
by Yinxiao Lu, Jun Zhu, Wenming Chen and Xin Ma
Electronics 2023, 12(20), 4319; https://doi.org/10.3390/electronics12204319 - 18 Oct 2023
Cited by 1 | Viewed by 1783
Abstract
In this work, a lightweight adaptive hybrid gait detection method with two inertial measurement units (IMUs) on the foot and thigh was developed and preliminarily evaluated. An adaptive detection algorithm is used to eliminate the pre-training phase and to modify parameters according to [...] Read more.
In this work, a lightweight adaptive hybrid gait detection method with two inertial measurement units (IMUs) on the foot and thigh was developed and preliminarily evaluated. An adaptive detection algorithm is used to eliminate the pre-training phase and to modify parameters according to the changes within a walking trial using an adaptive two-level architecture. The present algorithm has a two-layer structure: a real-time detection algorithm for detecting the current gait pattern and events at 100 Hz., and a short-time online training layer for updating the parameters of gait models for each gait pattern. Three typical walking patterns, including level-ground walking (LGW), stair ascent (SA), and stair descent (SD), and four events/sub-phases of each pattern, can be detected on a portable Raspberry-Pi platform with two IMUs on the thigh and foot in real-time. A preliminary algorithm test was implemented with healthy subjects in common indoor corridors and stairs. The results showed that the on-board model training and event decoding processes took 20 ms and 1 ms, respectively. Motion detection accuracy was 97.8% for LGW, 95.6% for SA, and 97.1% for SD. F1-scores for event detection were over 0.86, and the maximum time delay was steadily below 51 ± 32.4 ms. Some of the events in gait models of SA and SD seemed to be correlated with knee extension and flexion. Given the simple and convenient hardware requirements, this method is suitable for knee assistive device applications. Full article
(This article belongs to the Special Issue Advanced Wearable/Flexible Devices and Systems in Bioelectronics)
Show Figures

Figure 1

11 pages, 1920 KiB  
Article
A Highly Sensitive and Selective Optical Sensor for the On-Line Detection of Cesium in Water
by Alexis Depauw, Laura Jonusauskaite, Rasta Ghasemi, Jean-Pierre Lefevre, C. Mongin, Valérie Génot, Jacques Delaire and Isabelle Leray
Sensors 2023, 23(18), 7826; https://doi.org/10.3390/s23187826 - 12 Sep 2023
Cited by 5 | Viewed by 1718
Abstract
In this study, we have undertaken the development of two fluorescent sensors based on calixarene compounds for the purpose of detecting cesium in water. By introducing the sulfonate functional groups, we have considerably improved the water solubility of sensors, enabling complete dissolution of [...] Read more.
In this study, we have undertaken the development of two fluorescent sensors based on calixarene compounds for the purpose of detecting cesium in water. By introducing the sulfonate functional groups, we have considerably improved the water solubility of sensors, enabling complete dissolution of products in aqueous media and direct analysis of polluted water samples. Through rigorous experiments, we have demonstrated that the complexation of Cs+ ions with sensors 1 and 2 in water leads to a remarkable enhancement of fluorescence. This fluorescence enhancement serves as a reliable indication of cesium presence and allows for sensitive detection. To further advance the practical application of our sensors, we have successfully integrated calixarene sensors 1 and 2 into a microfluidic sensor chip. This integration has enabled real-time, on-line measurements and has resulted in the development of a portable detection device capable of detecting cesium ions in water samples at parts per billion (ppb) levels. This device holds great promise for environmental monitoring and assessment, providing a convenient and efficient solution for cesium detection. Our work represents a significant advancement in the field of cesium detection, displaying the efficacy of calixarene-based fluorescent sensors and their integration into microfluidic systems. The enhanced water solubility, fluorescence response, and portability of our detection device offers tremendous potential for applications in environmental monitoring, water quality assessment, and emergency response scenarios where rapid and accurate cesium detection is crucial. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

18 pages, 2475 KiB  
Systematic Review
Are Veterinary Students Using Technologies and Online Learning Resources for Didactic Training? A Mini-Meta Analysis
by Edlira Muca, Damiano Cavallini, Rosangela Odore, Mario Baratta, Domenico Bergero and Emanuela Valle
Educ. Sci. 2022, 12(8), 573; https://doi.org/10.3390/educsci12080573 - 22 Aug 2022
Cited by 32 | Viewed by 19615
Abstract
Over the last years, there has been an increase in online educational resources and media device use for educational purposes in veterinary settings. However, an overall analysis of these studies providing measurements of the use of learning resources and media devices could be [...] Read more.
Over the last years, there has been an increase in online educational resources and media device use for educational purposes in veterinary settings. However, an overall analysis of these studies providing measurements of the use of learning resources and media devices could be particularly useful for veterinary teachers. The evolution of technology, coupled with the advent of pandemic-related restrictions in person lessons, has made it imperative that educators consider how students may access educational material, as well as what type of educational material may be available to them. Databases including PubMed, Scopus, CAB Abstracts, and Web of Sciences were searched for relevant studies from January 2012 to June 2022. A mini-meta-analysis for proportions was performed using RStudio. Results highlight a high use of portable media devices with differences among countries, continued good use of traditional textbooks, moderate use of online tools, and low use of research papers. The results suggest that despite living in a technologically advanced world, veterinary students have attitudes towards digital resources that cannot be assumed. Full article
Show Figures

Figure 1

11 pages, 6540 KiB  
Article
A Real-Time Measurement-Modeling System for Ship Air Pollution Emission Factors
by Fan Zhou, Jing Liu, Hang Zhu, Xiaodong Yang and Yunli Fan
J. Mar. Sci. Eng. 2022, 10(6), 760; https://doi.org/10.3390/jmse10060760 - 31 May 2022
Cited by 13 | Viewed by 3578
Abstract
The lack of techniques for monitoring ship emissions all day and in all weather conditions to obtain real-time emission factor values is the main problem in understanding the characteristics of ship emissions, and there is still no perfect solution. In this study, a [...] Read more.
The lack of techniques for monitoring ship emissions all day and in all weather conditions to obtain real-time emission factor values is the main problem in understanding the characteristics of ship emissions, and there is still no perfect solution. In this study, a real-time measurement-modeling system was designed and implemented. The system was divided into three parts: (1) a portable exhaust monitoring device, which could be mounted on a drone, aircraft, patrol boat, dock, and bridge crane, as well as on the shore, to conduct all-weather and real-time online monitoring of ship emissions; (2) a monitoring information platform for ship emissions, based on a Spring + Spring MVC + MyBatis (SSM) framework and Vue front-end technology; and (3) a cloud server that received real-time ship emission measurement data and stored it after verification and analysis to calculate the pollutant gas and particulate matter emission factors. Following development, this system was used to monitor the emissions of ocean-going and inland river ships. Analysis of the acquired data showed that the system could effectively measure the emission factors of ship exhausts full-time in a variety of weather scenarios. This system can improve the efficiency of maritime law enforcement and provide technical support for promoting the construction of ship emission control areas. It can also help researchers obtain ship emission data, as well as an improved understanding of the emission characteristics of ships. Full article
(This article belongs to the Special Issue Application of Coastal/Ocean Sensors and Systems)
Show Figures

Figure 1

13 pages, 5620 KiB  
Communication
Universal Programmable Portable Measurement Device for Diagnostics and Monitoring of Industrial Fluid Power Systems
by Ryszard Dindorf and Piotr Wos
Sensors 2021, 21(10), 3440; https://doi.org/10.3390/s21103440 - 15 May 2021
Cited by 7 | Viewed by 3133
Abstract
This paper presents a new universal programmable portable measuring device (PMD) as a complete, accurate, and efficient solution for monitoring and technical diagnostics of industrial fluid power systems. PMD has programmable functions designed for recording, processing, and graphical visualization of measurement results at [...] Read more.
This paper presents a new universal programmable portable measuring device (PMD) as a complete, accurate, and efficient solution for monitoring and technical diagnostics of industrial fluid power systems. PMD has programmable functions designed for recording, processing, and graphical visualization of measurement results at the test stand or the place of operation of fluid power systems. PMD has a built-in WiFi communication module for transferring measurement data via Industrial Internet of Things (IIoT) technology for online remote monitoring of fluid power systems. PMD can be programmed for a variety of measuring tasks in servicing, repairing, diagnosing, and monitoring fluid power systems. For this purpose, the fluid dynamic quantity, mechanical quantity, and electrical quantity can be measured. The adjustment of the PMD to the indirect measurement of leakage flow rate in a compressed air system (CAS) is presented in detail. Measuring instruments and PMDs were connected to a branch of the pipeline. The tests used the measurement system to estimate the leakage flow rate through air small nozzles, as well as other CAS indicators. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

12 pages, 1574 KiB  
Article
KickStat: A Coin-Sized Potentiostat for High-Resolution Electrochemical Analysis
by Orlando S. Hoilett, Jenna F. Walker, Bethany M. Balash, Nicholas J. Jaras, Sriram Boppana and Jacqueline C. Linnes
Sensors 2020, 20(8), 2407; https://doi.org/10.3390/s20082407 - 23 Apr 2020
Cited by 71 | Viewed by 16732
Abstract
The demand for wearable and point-of-care devices has led to an increase in electrochemical sensor development to measure an ever-increasing array of biological molecules. In order to move from the benchtop to truly portable devices, the development of new biosensors requires miniaturized instrumentation [...] Read more.
The demand for wearable and point-of-care devices has led to an increase in electrochemical sensor development to measure an ever-increasing array of biological molecules. In order to move from the benchtop to truly portable devices, the development of new biosensors requires miniaturized instrumentation capable of making highly sensitive amperometric measurements. To meet this demand, we have developed KickStat, a miniaturized potentiostat that combines the small size of the integrated Texas Instruments LMP91000 potentiostat chip (Texas Instruments, Dallas, TX, USA) with the processing power of the ARM Cortex-M0+ SAMD21 microcontroller (Microchip Technology, Chandler, AZ, USA) on a custom-designed 21.6 mm by 20.3 mm circuit board. By incorporating onboard signal processing via the SAMD21, we achieve 1 mV voltage increment resolution and an instrumental limit of detection of 4.5 nA in a coin-sized form factor. This elegant engineering solution allows for high-resolution electrochemical analysis without requiring extensive circuitry. We measured the faradaic current of an anti-cocaine aptamer using cyclic voltammetry and square wave voltammetry and demonstrated that KickStat’s response was within 0.6% of a high-end benchtop potentiostat. To further support others in electrochemical biosensors development, we have made KickStat’s design and firmware available in an online GitHub repository. Full article
(This article belongs to the Special Issue Amperometric Sensing)
Show Figures

Figure 1

19 pages, 5740 KiB  
Article
A Non-Destructive Testing Method for Fault Detection of Substation Grounding Grids
by Xiujuan Wang, Zhihong Fu, Yao Wang, Renkuan Liu and Lin Chen
Sensors 2019, 19(9), 2046; https://doi.org/10.3390/s19092046 - 2 May 2019
Cited by 24 | Viewed by 4199
Abstract
The grounding grid is critical to the safety and stability of a power system. Corrosive cracking of the grounding conductor is the main cause of deterioration of grounding grid performance. Existing fault diagnosis methods for grounding grids are limited by the number and [...] Read more.
The grounding grid is critical to the safety and stability of a power system. Corrosive cracking of the grounding conductor is the main cause of deterioration of grounding grid performance. Existing fault diagnosis methods for grounding grids are limited by the number and distribution of grounding leads, and some of them cannot be used for online detection. This paper proposes a grounding grid detection method based on magnetic source excitation. The measuring device consists of four coils, two horizontal excitation coils, and two vertical receiving coils. The secondary magnetic field signal is extracted from the primary field and the background field by properly positioning the coils, such that the measured signal can reflect the underground media more accurately. The measuring device of the method is portable, the measurement process is contactless with the grounding grid, and it is not limited by the grounding leads. Furthermore, it has a strong anti-interference ability and can realize online detection. It was proven by simulations and experiments that the proposed method has a higher measurement accuracy and stronger anti-interference ability when compared with existing methods. This paper also discusses the influence of various factors such as the number and the location of the breakpoints, the frequency of the excitation source, the soil resistivity, and stratification from the measurement data. It was proven that the method has high precision and a wide application range, and is important for guiding significance and reference value in engineering applications. Full article
(This article belongs to the Special Issue Sensors Fusion in Non-Destructive Testing Applications)
Show Figures

Figure 1

10 pages, 1932 KiB  
Article
Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
by Ke Zhao, Yaoyao Ji, Yan Li and Ting Li
Sensors 2018, 18(1), 312; https://doi.org/10.3390/s18010312 - 21 Jan 2018
Cited by 18 | Viewed by 6486
Abstract
Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed to [...] Read more.
Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed to study the baseline characteristics of an in-house-built portable medical NIRS device over a long time (>3.5 h). We found that the measured baselines all formed perfect polynomial functions on phantom tests mimicking human bodies, which were identified by recent NIRS studies. More importantly, our study shows that the fourth-order polynomial function acted to distinguish performance with stable and low-computation-burden fitting calibration (R-square >0.99 for all probes) among second- to sixth-order polynomials, evaluated by the parameters R-square, sum of squares due to error, and residual. This study provides a straightforward, efficient, and quantitatively evaluated solution for online baseline removal for hemodynamic monitoring using NIRS devices. Full article
Show Figures

Figure 1

4 pages, 422 KiB  
Proceeding Paper
Performance Evaluation of Low-Cost BTEX Sensors and Devices within the EURAMET Key-VOCs Project
by Laurent Spinelle, Michel Gerboles, Gertjan Kok, Stefan Persijn and Tilman Sauerwald
Proceedings 2017, 1(4), 425; https://doi.org/10.3390/proceedings1040425 - 29 Aug 2017
Cited by 9 | Viewed by 3067
Abstract
The KEY-VOCs project is a EURAMET joint research project focused on key Volatile Organic Compounds (VOCs) in air. One of its activities is the evaluation of sensors-based measurement systems. In Europe, the monitoring of benzene in ambient air is mandatory as set by [...] Read more.
The KEY-VOCs project is a EURAMET joint research project focused on key Volatile Organic Compounds (VOCs) in air. One of its activities is the evaluation of sensors-based measurement systems. In Europe, the monitoring of benzene in ambient air is mandatory as set by the European Directive for air quality (AQD) [1]. This Directive states that the reference method of measurement shall consist of active or on-line sampling followed by gas chromatography [2]. These methods are time consuming, expensive to implement and not easily portable prohibiting more local estimation of the population exposure. However, the AQD allows using indicative measurements with higher uncertainty than those of the reference methods. Sensor systems are good candidates for indicative methods with the additional ability of near-to real-time measurements. Full article
(This article belongs to the Proceedings of Proceedings of Eurosensors 2017, Paris, France, 3–6 September 2017)
Show Figures

Figure 1

30 pages, 980 KiB  
Review
Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds
by Laurent Spinelle, Michel Gerboles, Gertjan Kok, Stefan Persijn and Tilman Sauerwald
Sensors 2017, 17(7), 1520; https://doi.org/10.3390/s17071520 - 28 Jun 2017
Cited by 346 | Viewed by 23582
Abstract
This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) [...] Read more.
This article presents a literature review of sensors for the monitoring of benzene in ambient air and other volatile organic compounds. Combined with information provided by stakeholders, manufacturers and literature, the review considers commercially available sensors, including PID-based sensors, semiconductor (resistive gas sensors) and portable on-line measuring devices as for example sensor arrays. The bibliographic collection includes the following topics: sensor description, field of application at fixed sites, indoor and ambient air monitoring, range of concentration levels and limit of detection in air, model descriptions of the phenomena involved in the sensor detection process, gaseous interference selectivity of sensors in complex VOC matrix, validation data in lab experiments and under field conditions. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

Back to TopTop