Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (214)

Search Parameters:
Keywords = plastic optical fibers

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 4522 KiB  
Article
A Two-Dimensional Position and Motion Monitoring System for Preterm Infants Using a Fiber-Optic Pressure-Sensitive Mattress
by Giulia Palladino, Zheng Peng, Deedee Kommers, Henrie van den Boom, Oded Raz, Xi Long, Peter Andriessen, Hendrik Niemarkt and Carola van Pul
Sensors 2025, 25(15), 4774; https://doi.org/10.3390/s25154774 - 3 Aug 2025
Viewed by 200
Abstract
Monitoring position and movements of preterm infants is important to ensure their well-being and optimal development. This study evaluates the feasibility of a pressure-sensitive fiber-optic mattress (FM), made entirely of plastic, for two-dimensional analysis of preterm infant movements and positioning. Before clinical use, [...] Read more.
Monitoring position and movements of preterm infants is important to ensure their well-being and optimal development. This study evaluates the feasibility of a pressure-sensitive fiber-optic mattress (FM), made entirely of plastic, for two-dimensional analysis of preterm infant movements and positioning. Before clinical use, we developed a simple, replicable, and cost-effective test protocol to simulate infant movements and positions, enabling early identification of technical limitations. Using data from 20 preterm infants, we assessed the FM’s potential to monitor posture and limb motion. FM-derived pressure patterns were compared with camera-based manual annotations to distinguish between different positions and out-of-bed moments, as well as limb-specific movements. Bench-test results demonstrated the FM’s sensitivity to motion and pressure changes, supporting its use in preclinical validation. Clinical data confirmed the FM’s reliability in identifying infant positions and movement patterns, showing an accuracy comparable to camera annotations. However, limitations such as calibration, sensitivity to ambient light, and edge-related artifacts were noted, indicating areas for improvement. In conclusion, the test protocol proved effective for early-stage evaluation of smart mattress technologies. The FM showed promising clinical feasibility for non-obtrusive monitoring of preterm infants, though further optimization is needed for robust performance in neonatal care. Full article
Show Figures

Figure 1

16 pages, 3783 KiB  
Article
Investigation of a New Stacking Pattern of Laminates with Approximately Constant Bending Stiffness
by Qingnian Liu, Yingfeng Shao, Yong Cai, Long Li and Fan Song
Polymers 2025, 17(8), 1098; https://doi.org/10.3390/polym17081098 - 18 Apr 2025
Viewed by 339
Abstract
To achieve laminates with constant bending stiffness to match the high precision requirement of optical systems made of carbon fiber reinforced plastic (CFRP), a new method, the normalized direction factor of bending stiffness (NDFBS), is proposed based on the normalized geometric factor of [...] Read more.
To achieve laminates with constant bending stiffness to match the high precision requirement of optical systems made of carbon fiber reinforced plastic (CFRP), a new method, the normalized direction factor of bending stiffness (NDFBS), is proposed based on the normalized geometric factor of bending stiffness. Using NDFBS and its variance (VNDFBS), we investigate two common stacking patterns, I and II ([(θ1)m/(θ2)m/…/(θp)m]S and [(θ1/θ2/…/θp)m]S) and our proposed new stacking pattern, Pattern III ([(θ1/θ2/…/θp)S]m) based on the initial quasi-isotropic laminates, [θ1/θ2/…/θp]. The bending stiffness of the stacking sequence [(45/−45/0/90)S]2 tends to be more uniform than that of [45/−45/0/90]2S, and the order of uniformity in bending stiffness of other stacking sequences is [(60/0/−60)S]4 > [60/0/−60]4S > [(60/0/−60)S]2 > [60/0/−60]2S. Both theoretical deviations and experimental observations confirm that as the cycle number m increased, the uniformity in bending stiffness is improved gradually, except for that of Pattern I. As the cycle number increased, the speed of Pattern III approaching the constant bending stiffness was faster than that of Patterns I and II. Notably, to achieve a nearly identical uniformity in bending stiffness, only the square root of the cycle number of Pattern II was enough for Pattern III. Based on the same initial laminate and cycle number, Pattern III exhibited more uniform bending stiffness and strength, which are appropriate for precision optical components that require dimensional stability, such as space mirrors. Full article
Show Figures

Figure 1

20 pages, 5836 KiB  
Article
Biodegradable Polymer Composites Based on Polypropylene and Hybrid Fillers for Applications in the Automotive Industry
by Alina Ruxandra Caramitu, Magdalena Valentina Lungu, Romeo Cristian Ciobanu, Ioana Ion, Delia Pătroi, Beatrice Gabriela Sbârcea, Virgil Emanuel Marinescu and Doina Constantinescu
Processes 2025, 13(4), 1078; https://doi.org/10.3390/pr13041078 - 3 Apr 2025
Viewed by 797
Abstract
This study focuses on the development and characterization of biodegradable polymer composites consisting of a polypropylene (PP) matrix, carbon black pigment, and hybrid fillers. The fillers incorporated into these composites consisted of a blend of fibers and particles derived from natural, biodegradable materials, [...] Read more.
This study focuses on the development and characterization of biodegradable polymer composites consisting of a polypropylene (PP) matrix, carbon black pigment, and hybrid fillers. The fillers incorporated into these composites consisted of a blend of fibers and particles derived from natural, biodegradable materials, such as flax fibers (FFs) and wood flour (WF) particles. The compositions of polymer material were expressed as PP/FF/WF weight ratios of 100/0/0, 70/5/25, and 70/10/20. The polymer materials were prepared using conventional plastic processing methods like extrusion to produce composite mixtures, followed by melt injection to manufacture the samples needed for characterization. The structural characterization of the polymer materials was conducted using optical microscopy and X-ray diffraction (XRD) analyses, while thermal, mechanical, and dielectric properties were also evaluated. Additionally, their biodegradation behavior under mold exposure was assessed over six months. The results were analyzed comparatively, and the optimal composition was identified as the polymer composite containing the highest flax fiber content, namely PP + 10 wt.% flax fiber + 20 wt.% wood flour. Full article
(This article belongs to the Special Issue Development and Characterization of Advanced Polymer Nanocomposites)
Show Figures

Figure 1

15 pages, 3027 KiB  
Article
Microplastics in Inland Saline Lakes of the Central Ebro Basin, NE Spain
by Katia Hueso-Kortekaas, Noemí Delgado-Mellado, Javier Calzada-Funes, Carlos Sanchez-Mata, Carmen Castañeda and María del Mar Cledera-Castro
Water 2025, 17(7), 989; https://doi.org/10.3390/w17070989 - 28 Mar 2025
Viewed by 1243
Abstract
Saline lakes are rare and fragile habitats with a high conservation and scientific interest. We have studied the presence of microplastics (MPs) in the water of four inland saline lakes located in the Central Ebro Basin (CEB), NE Spain. Quantification and characterization of [...] Read more.
Saline lakes are rare and fragile habitats with a high conservation and scientific interest. We have studied the presence of microplastics (MPs) in the water of four inland saline lakes located in the Central Ebro Basin (CEB), NE Spain. Quantification and characterization of MPs were performed by optical microscopy and micro-Fourier Transform Infrared Spectroscopy (micro-FTIR). MPs analyzed covered the 5–5000 μm range. Most of the MPs collected were contained in the 250–500 and 500–1000 μm ranges. The concentration of MPs varied from 850 ± 271 to 1556 ± 59 MPs/L, fibers being the most dominant typology. Seven different colors were observed, the most abundant being black, and seven types of plastic were identified, polyester, polyethylene terephthalate, and nylon the most abundant. The smallest lakes presented a more homogeneous MP size distribution and a wider variety in color and polymer composition. This work shows that the MP concentration in these lakes is at least one order of magnitude higher than previous values reported in similar environments, and it is expected to multiply fast. This highlights the importance of the hydrological characteristics of these lakes, the evapotranspiration being the only water outflow, the atmospheric deposition of MPs, and other anthropogenic causes. Full article
(This article belongs to the Section Water Quality and Contamination)
Show Figures

Graphical abstract

21 pages, 6476 KiB  
Article
First Attempt to Study Sedimentological Characteristics and Contamination Levels of Bottom Sediments in the Faanu Mudugau Blue Hole (Ari Atoll, Maldives)
by Laura Cutroneo, Sarah Vercelli, Monica Montefalcone and Marco Capello
Environments 2025, 12(4), 100; https://doi.org/10.3390/environments12040100 - 25 Mar 2025
Viewed by 639
Abstract
Environmental contamination is ubiquitous and even in the ocean, signs of contamination of different types (chemical, biological, or plastic) are detected in all kinds of environments. In this study, a sediment core was sampled at the bottom of the Blue Hole of the [...] Read more.
Environmental contamination is ubiquitous and even in the ocean, signs of contamination of different types (chemical, biological, or plastic) are detected in all kinds of environments. In this study, a sediment core was sampled at the bottom of the Blue Hole of the Maldives (Ari Atoll) to make a first characterization of the sediment in terms of its grain size and organic–inorganic matter composition and to assess the sediment contamination levels in terms of trace elements (by ICP-MS analysis) and the eventual presence of microplastics (by optical classification and microRaman analysis of items). High concentrations of Hg (a maximum value of 0.145 ppm at the bottom layer of the core), Cd (a maximum value of 0.65 ppm at the core surface layer), and As (9.4 ppm at the top of the core) were highlighted at different layers of the sediment core. Plastic polymers were not detected in the sediment core, but 51 fibers characterized by the presence of artificial dyes or additives were found in the core (a mean of 5.7 fibers for each slice). The results confirmed the sediment contamination of the Maldivian Blue Hole, supporting the hypothesis of contamination due to ineffective waste management within the archipelago and mass tourism affecting the atolls. Full article
Show Figures

Graphical abstract

12 pages, 2709 KiB  
Article
An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection
by Nunzio Cennamo, Francesco Arcadio, Chiara Marzano, Rosalba Pitruzzella, Mimimorena Seggio, Maria Pesavento, Stefano Toldo, Antonio Abbate and Luigi Zeni
Sensors 2025, 25(3), 930; https://doi.org/10.3390/s25030930 - 4 Feb 2025
Viewed by 1067
Abstract
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where [...] Read more.
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where the bioreceptor’s (protein antibody) molecular weight is roughly ten times that of the analyte (protein interleukin), while intracellular bioreceptors and small molecules at low molecular weight interactions have already been demonstrated via the same point-of-care test (POCT). The POCT was implemented by a white light source and a spectrometer connected via two POF-based chips connected in series: an innovative microcuvette chip and a D-shaped POF surface plasmon resonance (SPR) probe. In particular, the POF microcuvette chip was achieved by drilling three micro holes in the core of a modified POF. Instead of performing a functionalization step, the micro holes were filled with a specific receptor solution for the analyte (one microliter at the femtomolar level), which selectively captured the target (e.g., cytokine) when the samples were dropped over the filled micro holes (twenty microliters at the attomolar level). Three interleukins, IL-1β, IL-17A, and IL-18, were detected in the attomolar concentrations range by monitoring the resonance wavelength shift over time due to the cytokine/antibody (protein–protein) interaction. The POF-based device was proven to be effective for detecting several interleukins at the attomolar level in a few minutes and without functionalization processes. Full article
(This article belongs to the Special Issue Advanced Optics and Photonics Technologies for Sensing Applications)
Show Figures

Figure 1

13 pages, 3539 KiB  
Article
Compact and Real-Time Radiation Dosimeter Using Silicon Photomultipliers for In Vivo Dosimetry in Radiation Therapy
by Jeongho Kim, Jeehoon Park, Byungdo Park, Yonghoon Kim, Beomjun Park and So Hyun Park
Sensors 2025, 25(3), 857; https://doi.org/10.3390/s25030857 - 31 Jan 2025
Cited by 3 | Viewed by 990
Abstract
Existing dosimeters for radiation therapy are typically large, and their performance in in vivo system applications has not been assessed. This study develops a compact real-time dosimeter using silicon photomultipliers, plastic scintillators, and optical fibers and evaluates its in vivo applicability for radiation [...] Read more.
Existing dosimeters for radiation therapy are typically large, and their performance in in vivo system applications has not been assessed. This study develops a compact real-time dosimeter using silicon photomultipliers, plastic scintillators, and optical fibers and evaluates its in vivo applicability for radiation therapy. Dose calibration, dose-rate dependency and linearity, and short-term repeatability tests were conducted using solid water phantoms and bolus materials, and in vivo dosimetry was performed using an in-house phantom. The characterization evaluation results showed high linearity, with a coefficient of determination of 0.9995 for dose rates of 100–600 monitoring units (MU)/min, confirming an error rate within 2% when converted to dosage. In the short-term repeatability tests, the dosimeter exhibited good characteristics, with relative standard deviation (RSD) values lower than 2% for each beam delivery and an RSD value of 0.03% over ten beam deliveries. Dose measurements using the phantom indicated an average error rate of 3.83% compared to the values calculated using the treatment planning system. These results demonstrate a performance comparable to that of commercial metal-oxide-semiconductor field-effect transistors and plastic scintillator-based dosimeters. Based on these findings, the developed dosimeter has significant potential for in vivo radiation therapy applications. Full article
(This article belongs to the Special Issue Advanced Silicon Photomultiplier Based Sensors)
Show Figures

Figure 1

36 pages, 1986 KiB  
Review
Exploring Innovative Approaches for the Analysis of Micro- and Nanoplastics: Breakthroughs in (Bio)Sensing Techniques
by Denise Margarita Rivera-Rivera, Gabriela Elizabeth Quintanilla-Villanueva, Donato Luna-Moreno, Araceli Sánchez-Álvarez, José Manuel Rodríguez-Delgado, Erika Iveth Cedillo-González, Garima Kaushik, Juan Francisco Villarreal-Chiu and Melissa Marlene Rodríguez-Delgado
Biosensors 2025, 15(1), 44; https://doi.org/10.3390/bios15010044 - 13 Jan 2025
Cited by 10 | Viewed by 3985
Abstract
Plastic pollution, particularly from microplastics (MPs) and nanoplastics (NPs), has become a critical environmental and health concern due to their widespread distribution, persistence, and potential toxicity. MPs and NPs originate from primary sources, such as cosmetic microspheres or synthetic fibers, and secondary fragmentation [...] Read more.
Plastic pollution, particularly from microplastics (MPs) and nanoplastics (NPs), has become a critical environmental and health concern due to their widespread distribution, persistence, and potential toxicity. MPs and NPs originate from primary sources, such as cosmetic microspheres or synthetic fibers, and secondary fragmentation of larger plastics through environmental degradation. These particles, typically less than 5 mm, are found globally, from deep seabeds to human tissues, and are known to adsorb and release harmful pollutants, exacerbating ecological and health risks. Effective detection and quantification of MPs and NPs are essential for understanding and mitigating their impacts. Current analytical methods include physical and chemical techniques. Physical methods, such as optical and electron microscopy, provide morphological details but often lack specificity and are time-intensive. Chemical analyses, such as Fourier transform infrared (FTIR) and Raman spectroscopy, offer molecular specificity but face challenges with smaller particle sizes and complex matrices. Thermal analytical methods, including pyrolysis gas chromatography–mass spectrometry (Py-GC-MS), provide compositional insights but are destructive and limited in morphological analysis. Emerging (bio)sensing technologies show promise in addressing these challenges. Electrochemical biosensors offer cost-effective, portable, and sensitive platforms, leveraging principles such as voltammetry and impedance to detect MPs and their adsorbed pollutants. Plasmonic techniques, including surface plasmon resonance (SPR) and surface-enhanced Raman spectroscopy (SERS), provide high sensitivity and specificity through nanostructure-enhanced detection. Fluorescent biosensors utilizing microbial or enzymatic elements enable the real-time monitoring of plastic degradation products, such as terephthalic acid from polyethylene terephthalate (PET). Advancements in these innovative approaches pave the way for more accurate, scalable, and environmentally compatible detection solutions, contributing to improved monitoring and remediation strategies. This review highlights the potential of biosensors as advanced analytical methods, including a section on prospects that address the challenges that could lead to significant advancements in environmental monitoring, highlighting the necessity of testing the new sensing developments under real conditions (composition/matrix of the samples), which are often overlooked, as well as the study of peptides as a novel recognition element in microplastic sensing. Full article
(This article belongs to the Special Issue Micro-nano Optic-Based Biosensing Technology and Strategy)
Show Figures

Figure 1

17 pages, 17836 KiB  
Article
Functionalization of Continuous Fiber-Reinforced Thermoplastic Pultrusion Profiles by Welding
by Calvin Ebert, Marcel Nick Dürr and Christian Bonten
J. Compos. Sci. 2025, 9(1), 6; https://doi.org/10.3390/jcs9010006 - 2 Jan 2025
Cited by 2 | Viewed by 1175
Abstract
Highly filled thermoplastic profiles, produced by in situ pultrusion, offer excellent mechanical properties, but further processing is necessary to expand the range of their applications. Due to the thermoplastic matrix, these materials are particularly well-suited for thermal welding processes. However, the high fiber [...] Read more.
Highly filled thermoplastic profiles, produced by in situ pultrusion, offer excellent mechanical properties, but further processing is necessary to expand the range of their applications. Due to the thermoplastic matrix, these materials are particularly well-suited for thermal welding processes. However, the high fiber content of up to 70 vol.-% presents a significant challenge in welding, an aspect that has not yet been thoroughly investigated in the existing literature. This study focuses on the further processing of the highly-filled profiles by adapting the classic hot tool welding process with the aim of investigating the underlying welding mechanism. An IR line-emitter is used to melt the PA6 matrix of the fiber-reinforced plastic component while the second adherend (unfilled PA6) is melted with a classic heating element. Afterward, the joints are tested for tensile and bending strength. The results of these mechanical tests demonstrate that a strong bond can be formed between the adherends. The joint strength reached values of up to 39 MPa, which corresponds to a welding factor of 0.81. Optical examination of the weld seam reveals a reason for the mechanical performance. At high joining pressures, a form-fit is created between the continuous fibers in the profile and the welded-on unfilled PA6. Full article
(This article belongs to the Topic Advanced Composites Manufacturing and Plastics Processing)
Show Figures

Figure 1

10 pages, 3024 KiB  
Article
Characterization of an Inorganic Powder-Based Scintillation Detector Under a UHDR Electron Beam
by Daline Tho and Sam Beddar
Sensors 2024, 24(24), 8064; https://doi.org/10.3390/s24248064 - 18 Dec 2024
Cited by 1 | Viewed by 848
Abstract
(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder [...] Read more.
(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber. We evaluated the dependence of the detector on dose per pulse (DPP), pulse repetition frequency (PRF), and pulse width (PW). Additionally, we determined the stability and the reproducibility of the detector. (3) Results: The signal ratio between the PMMA clear optical fiber and the ZnS:Ag scintillator was around 210. ZnS:Ag produced a signal yield 54 times greater than that of a BCF-12 plastic scintillator. Signal variation with PRF changes was under 0.5%. The signal was linear to the integrated dose up to the maximum deliverable dose, 180 Gy. The variation in signal was linear to the change in both PW and DPP. Regarding stability, the standard deviation of 10 consecutive irradiations was 0.83%. For the reproducibility, all daily measurements varied within ±1.5%. (4) Conclusions: These findings show that the ZnS:Ag detector can be used for accurate dosimetry with UHDR beams. Full article
(This article belongs to the Special Issue Optical Fiber Sensors in Radiation Environments: 2nd Edition)
Show Figures

Figure 1

13 pages, 3213 KiB  
Article
Tailored Compositions of Ni-Ti-Sn Nanopowders Deposited on Polymer Fiber Optics Through Flash Evaporation
by Elango Natarajan, Anil Chouhan, Santheraleka Ramanathan, Kalaimani Markandan, Santhosh Mozhuguan Sekar, Chun Kit Ang, Nagarajan Deivanayagampillai and Gérald Franz
J. Compos. Sci. 2024, 8(12), 526; https://doi.org/10.3390/jcs8120526 - 13 Dec 2024
Cited by 1 | Viewed by 878
Abstract
Fiber coatings protect the glass surface of fiber from extrinsic environmental factors. The coating of shape memory alloy over fiber is useful in sensor fabrication where the state of deformation is affected by the phase transformation of the coated material. In addition, coated [...] Read more.
Fiber coatings protect the glass surface of fiber from extrinsic environmental factors. The coating of shape memory alloy over fiber is useful in sensor fabrication where the state of deformation is affected by the phase transformation of the coated material. In addition, coated plastic fibers can be used in elevated temperature environments. To this end, the present research aims to investigate the effect of the Ni-Ti-Sn composite coating over the fiber. Homogeneous particle distribution, agglomeration, porosity and the ability to obtain uniform coating thickness have been general concerns in fiber coatings. Hence, the present study comprehensively investigated the mechanical and thermal behavior as well as morphological properties of Ni-Ti-Sn nanopowders deposited on polymer fiber optics. Five sets of polyamide-coated samples with different Ni-Ti-Sn proportions were fabricated and characterized. Morphological studies confirmed that an even coating thickness enhanced the mechanical integrity and optical performance. The optimum composition demonstrated superior tensile strength of 29.5 MPa and a 25% increase in elongation compared to the uncoated sample. The Ni-Ti-Sn alloy composition investigated in the present study is promising for industrial applications where thermal stability and mechanical performance are warranted. Full article
(This article belongs to the Special Issue Polymer Composites and Fibers, 3rd Edition)
Show Figures

Figure 1

11 pages, 1828 KiB  
Article
Differentiation of Amaranthus Species and Estimation of Their Polyphenolic Compounds and Antioxidant Potential Using Near-Infrared Spectroscopy
by Svetoslava Terzieva, Neli Grozeva, Milena Tzanova, Petya Veleva, Mariya Gerdzhikova and Stefka Atanassova
Plants 2024, 13(23), 3370; https://doi.org/10.3390/plants13233370 - 30 Nov 2024
Viewed by 1001
Abstract
Amaranthus species are rich in protein, fiber, minerals, and other nutrients and have various health benefits. The genus is taxonomically difficult due to the high phenotypic plasticity and the spontaneous interspecies introgression and hybridization between species. The purpose of this study is to [...] Read more.
Amaranthus species are rich in protein, fiber, minerals, and other nutrients and have various health benefits. The genus is taxonomically difficult due to the high phenotypic plasticity and the spontaneous interspecies introgression and hybridization between species. The purpose of this study is to evaluate the possibilities of near-infrared spectroscopy (NIRS) for the taxonomic differentiation of some of the species common in Bulgaria and estimate their polyphenolic compounds. Tested samples were collected from six Bulgarian floristic regions: Amaranthus albus L., A. blitum L., A. deflexus L., A. hybridus L., and A. retroflexus L. were studied. The NIR spectra of dried and ground leaf and stalk samples were measured by NIRQuest 512 (region 900–1700 nm) using a fiber-optic probe. Soft independent modeling of class analogy (SIMCA) was used to develop the classification models and PLS regression for the quantitative determination of their polyphenolic compounds and antioxidant potential. There were statistically significant differences in the measured values of polyphenolic compounds and antioxidant potential among the tested species. NIRS allowed an accurate determination of these parameters. The performance of developed SIMCA models for the discrimination of species was very high. The precision of determination varied from 98.2 to 100%, and the total accuracy was 98.34%. The results show successful differentiation of the taxonomic species. Full article
(This article belongs to the Section Phytochemistry)
Show Figures

Figure 1

18 pages, 3739 KiB  
Article
An MIP-Based PFAS Sensor Exploiting Nanolayers on Plastic Optical Fibers for Ultra-Wide and Ultra-Low Detection Ranges—A Case Study of PFAS Detection in River Water
by Rosalba Pitruzzella, Alessandro Chiodi, Riccardo Rovida, Francesco Arcadio, Giovanni Porto, Simone Moretti, Gianfranco Brambilla, Luigi Zeni and Nunzio Cennamo
Nanomaterials 2024, 14(21), 1764; https://doi.org/10.3390/nano14211764 - 3 Nov 2024
Cited by 3 | Viewed by 3065
Abstract
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance [...] Read more.
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance (SPR) phenomena. The sensor is realized by the coupling of an SPR-POF platform with a novel chemical chip based on different polymeric nanolayers over the core of a D-shaped POF, one made up of an optical adhesive and one of a molecularly imprinted polymer (MIP) for PFAS. The chemical chip is used to launch the light into the SPR D-shaped POF platform, so the interaction between the analyte and the MIP’s sites can be used to modulate the propagated light in the POFs and the SPR phenomena. Selectivity tests and dose–response curves by standard PFOA water solutions were carried out to characterize the detection range sensor response, obtaining a wide PFAS response range, from 1 ppt to 1000 ppt. Then, tests performed on river water samples collected from the Bormida river paved the way for the applicability of the proposed approach to a real scenario. Full article
Show Figures

Figure 1

15 pages, 2261 KiB  
Article
Optical Fiber Technology for Efficient Daylighting and Thermal Control: A Sustainable Approach for Buildings
by Lokesh Udhwani, Archana Soni, Erdem Cuce and Sudhakar Kumarasamy
Eng 2024, 5(4), 2680-2694; https://doi.org/10.3390/eng5040140 - 18 Oct 2024
Cited by 3 | Viewed by 2354
Abstract
Different direct solar harvesting systems for daylighting are being explored to achieve high uniform illumination deep within buildings at minimal cost. A promising solution to make these systems cost-effective is the use of plastic optical fibers (POFs). However, heat-related issues with low-cost POFs [...] Read more.
Different direct solar harvesting systems for daylighting are being explored to achieve high uniform illumination deep within buildings at minimal cost. A promising solution to make these systems cost-effective is the use of plastic optical fibers (POFs). However, heat-related issues with low-cost POFs need to be addressed for the widespread adoption of efficient daylighting technologies. Previous studies have explored solutions for this overheating problem, but their effectiveness remains uncertain. This study proposes a low-cost fiber optic daylighting system integrated with a newly patented mechanical component designed to secure the fiber optic bundle at the focal point, providing three levels of heat filtration while ensuring uniform illumination. Our methodology involves selecting a small area, installing the setup, and measuring both heat and light readings, followed by validation through software simulations. The operational principle of this technology is explained, and experimental tests using lux meters and infrared thermometers were conducted to investigate the system’s characteristics. The three-level heat filtration device reduces temperature by approximately 35 °C at the surface of the optical fiber, and the average illumination of the room is around 400 lux. These results were further verified using RELUX simulation software. The findings demonstrate the promising potential of this new device in solar heat filtration and achieving uniform illumination. Recommendations for mitigating overheating damage and exploring heat filtering possibilities in new parabolic solar daylighting systems for further research are also provided. Full article
(This article belongs to the Special Issue Feature Papers in Eng 2024)
Show Figures

Figure 1

15 pages, 1648 KiB  
Article
Multi-Directional Strain Measurement in Fiber-Reinforced Plastic Based on Birefringence of Embedded Fiber Bragg Grating
by Chunhua Zhou, Changhao Chen, Zilong Ye, Qi Wu and Ke Xiong
Sensors 2024, 24(19), 6190; https://doi.org/10.3390/s24196190 - 24 Sep 2024
Cited by 1 | Viewed by 1412
Abstract
Embedded fiber Bragg gratings are increasingly applied for in-situ strain measurement in fiber-reinforced plastics, integral to high-end aerospace equipment. Existing research primarily focuses on in-plane strain measurement, limited by the fact that fiber Bragg gratings are mainly sensitive to axial strain. However, out-of-plane [...] Read more.
Embedded fiber Bragg gratings are increasingly applied for in-situ strain measurement in fiber-reinforced plastics, integral to high-end aerospace equipment. Existing research primarily focuses on in-plane strain measurement, limited by the fact that fiber Bragg gratings are mainly sensitive to axial strain. However, out-of-plane strain measurement is equally important for comprehending structural deformation. The birefringence of fiber Bragg gratings shows promise for addressing this problem; yet, the strain transfer relationship between composites and optical fibers, along with the decoupling method for multi-directional strains, remains inadequately explored. This study introduces an innovative method for multi-directional strain measurement in fiber-reinforced plastics using the birefringence of a single-fiber Bragg grating. The strain transfer relationship between composites and embedded optical fibers was derived based on Kollar’s analytical model, leading to the development of a multi-directional strain decoupling methodology. This method was experimentally validated on carbon fiber/polyetherimide laminates under thermo-mechanical loading. Its reliability was confirmed by comparing experimental results and finite element simulations. These findings significantly broaden the application scenarios of fiber Bragg gratings, advancing the in-situ measurement technology crucial for the next generation of high-end aerospace equipment. Full article
Show Figures

Figure 1

Back to TopTop