Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (15)

Search Parameters:
Keywords = pink aesthetic score

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2395 KiB  
Article
Immediately Placed Single Locking-Taper Implants in the Aesthetic Area of Upper Maxilla: A Short-Term Pilot Study
by Giorgio Lombardo, Annarita Signoriello, Alessandro Zangani, Alessia Pardo, Mauro Marincola, Elena Messina, Miriana Gualtieri, Giovanni Corrocher, Massimo Albanese and Paolo Faccioni
Prosthesis 2025, 7(3), 60; https://doi.org/10.3390/prosthesis7030060 - 27 May 2025
Viewed by 555
Abstract
Background: As the rehabilitation of the upper anterior maxilla primarily requires high predictability of successful aesthetic outcomes, procedures of immediate implant placement are frequently employed. The aim of this pilot study was to retrospectively evaluate the short-term outcomes of a protocol of immediate [...] Read more.
Background: As the rehabilitation of the upper anterior maxilla primarily requires high predictability of successful aesthetic outcomes, procedures of immediate implant placement are frequently employed. The aim of this pilot study was to retrospectively evaluate the short-term outcomes of a protocol of immediate implant placement in fresh extraction sockets, followed by immediate non-functional provisional restorations. Methods: Patients were treated for the replacement of maxillary central or lateral incisors, or cuspid teeth with a single-crown locking-taper implant. Clinical and photographic records were retrospectively compared between the teeth prior to extraction (T0) and restorations one year after prosthetic loading (T1). Outcomes were analyzed using the Pink Esthetic Score (PES), according to the patient’s phenotype (thin/thick), with or without the use of connective tissue graft (CTG). Results: The overall mean PES of 25 implants treated was 9.24 ± 2.36 at T0 and 9.60 ± 1.70 at T1. Comparison of groups between T0 and T1 revealed significant PES variations (p = 0.04), with the best and the worst scores, respectively, registered for thin + CTG group (from 7.50 ± 1.91 to 9.75 ± 2.87) and thin group (from 11.33 ± 2.33 to 10 ± 0.89); moderate increases were assessed for thick group (from 8.44 ± 2.40 to 9.44 ± 2.12) and thick + CTG group (from 9.50 ± 1.04 to 9.33 ± 0.81). Conclusions: Within the limits of a short-term analysis of a small number of patients, immediate implant rehabilitation for aesthetic areas of the upper maxilla can be assumed as a safe and predictable protocol. Concomitant use of CTG seems to provide beneficial effects in thin phenotypes, not any additional value in thick phenotypes. Full article
(This article belongs to the Section Prosthodontics)
Show Figures

Figure 1

11 pages, 698 KiB  
Article
Rehabilitation Using Implants with Sloped Platform Edge vs. Standard Platform with Guided Bone Regeneration: A Randomized Control Clinical Trial
by Igor Ashurko, Andrey Samsonov, Anna Galyas, Marina Petukhova, Svetlana Tarasenko and Alexey Unkovskiy
Dent. J. 2024, 12(7), 205; https://doi.org/10.3390/dj12070205 - 4 Jul 2024
Viewed by 1194
Abstract
The purpose of this study was to evaluate the vertical bone loss after using different techniques: sloped implants or standard implants with guided bone regeneration. Patients with tooth gap and horizontal bone deficiency were randomly allocated to the test group (implants with sloped [...] Read more.
The purpose of this study was to evaluate the vertical bone loss after using different techniques: sloped implants or standard implants with guided bone regeneration. Patients with tooth gap and horizontal bone deficiency were randomly allocated to the test group (implants with sloped platform—SLP) and control group (standard design implants with guided bone regeneration—GBR). The primary outcome was bone loss (6 months after finishing the prosthetic treatment). Secondary outcomes included the following: patient-reported outcome measures (PROMs), post-operative edema, keratinized mucosa width, and pink aesthetic score (PES). The average bone loss at 6 months was 0.23 ± 0.15 mm and 1.03 ± 0.37 mm in the SLP and GBR groups, respectively. The SLP group was characterized by lower pain intensity the first 7 days (p < 0.001), lower post-operative edema (p < 0.001), lower consumption of NSAIDs on days 1, 3, 5, and 7 (p = 0.002, <0.001, <0.001, and 0.008), and lower total OHIP-14 (p = 0.047) on day 7. The keratinized mucosa width was 3.7 (3.4–4.0) mm and 2 (1.4–2.0) mm in the SLP and GBR groups, respectively. The preservation of the mesial, distal papillae, and the level of soft tissue correspondence were significantly higher in the SLP group (p = 0.003, 0.038, <0.001). In the SLP group, more natural color and better texture of soft tissues were found (p = 0.048, p = 0.041). The use of implants with a sloped platform resulted in superior outcomes compared to the standard-design implants with GBR. Full article
(This article belongs to the Section Dental Implantology)
Show Figures

Graphical abstract

12 pages, 990 KiB  
Article
Clinical, Radiological, and Aesthetic Outcomes after Placement of a Bioactive-Surfaced Implant with Immediate or Delayed Loading in the Anterior Maxilla: 1-Year Retrospective Follow-Up Study
by Roberta Iacono, Yaniv Mayer, Gaetano Marenzi, Balan Vitor Ferreira, Godoy Eduardo Pires, Marco Migliorati and Francesco Bagnasco
Prosthesis 2023, 5(3), 610-621; https://doi.org/10.3390/prosthesis5030043 - 7 Jul 2023
Cited by 16 | Viewed by 2746
Abstract
Background: Dental implants have become the standard for replacing missing teeth. However, patients’ demands for shorter treatment times and the desire for aesthetics in their results can complicate the rehabilitation process, particularly when poor-quality bone is involved. In order to address these challenges, [...] Read more.
Background: Dental implants have become the standard for replacing missing teeth. However, patients’ demands for shorter treatment times and the desire for aesthetics in their results can complicate the rehabilitation process, particularly when poor-quality bone is involved. In order to address these challenges, new methods of treating implant surfaces have been introduced. These methods aim to make the implants superhydrophilic and bioactive, enhancing their functionality and interactions with the surrounding tissues. Aim: The aim of the study was to retrospectively examine the efficacy of a superhydrophilic and bioactive implant for treatment of the edentulous maxillary anterior area. The study also aimed to evaluate whether this improved implant surface, by enhancing the osseointegration processes, could serve as a factor in speeding up the loading protocols. Materials and Methods: For this retrospective study, a total of 13 implants were included: 6 delayed restored implants and 7 immediately loaded implants placed in the anterior maxillary area. Clinical, radiographic, and esthetic outcomes were assessed. Baseline measurements of the insertion torque value (ITV) and stability implant quotient (ISQ) were recorded for all implants. In the early-loaded group, these measurements were also taken 30 days (t30) and 45 days (t45) after the placement of the implant to monitor their changes over time. Marginal bone loss (MBL) was calculated according to the changes in marginal bone level on intraoral X-rays taken at two different time points: at baseline and one year after loading. To evaluate the esthetic results, the pink esthetic score (PES) and the white esthetic score (WES) were assessed. For this evaluation, intraoral photographs were taken one year after implant loading. Results: A total of 7 implants were immediately restored, with a mean ITV of 32.29 ± 9.01 Ncm and a mean ISQ of 72.71 ± 2.81. These implants were placed in a bone environment with a mean density of 410.00 ± 194.42 HU. On the other hand, 6 implants with delayed loading had a mean ITV of 28.50 ± 3.27 Ncm, an ISQ of 67.92 ± 8.43, and a mean bone density of 607.50 ± 140.83 HU. The mean PES and WES after 1 year were, respectively, 8.71 ± 1.89 and 8.57 ± 0.79 for immediate and 8.33 ± 1.36 and 9.17 ± 1.33 for delayed-loaded implants. At 12 months after loading, the immediately loaded group had a MBL of 0.29 ± 0.29 mm, while the delayed-loaded group had a MBL of 0.33 ± 0.25. No statistically significant differences between the two treatment groups were found for any of the evaluated outcomes. Conclusions: Despite the limitations of this study, the obtained results may support the use of a superhydrophilic and bioactive implant surface for implant-prosthetic rehabilitation in critical loading protocols with satisfactory esthetic results. Full article
(This article belongs to the Collection Oral Implantology: Current Aspects and Future Perspectives)
Show Figures

Figure 1

16 pages, 2191 KiB  
Systematic Review
CAD/CAM Abutments in the Esthetic Zone: A Systematic Review and Meta-Analysis of Soft Tissue Stability
by Diego Lops, Eugenio Romeo, Magda Mensi, Giuseppe Troiano, Khrystyna Zhurakivska, Massimo Del Fabbro and Antonino Palazzolo
J. Clin. Med. 2023, 12(11), 3847; https://doi.org/10.3390/jcm12113847 - 4 Jun 2023
Cited by 1 | Viewed by 2132
Abstract
Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare [...] Read more.
Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments. The present review was registered with PROSPERO (CRD42020161875) and the protocol was developed according to the PRISMA statement. An electronic search was performed on three databases (PubMed, Embase and Cochrane Central) up to May 2023. Data extraction was followed by qualitative and quantitative analysis of the included studies. Three randomized controlled clinical trials and three controlled clinical trials (number of patients = 230; number of dental implants = 230) with a follow-up of between 12 and 36 months were included. No significant differences were observed between prefabricated versus customized (CAD/CAM) abutments regarding midfacial mucosal recession, interproximal papillae and pink aesthetic score (PES) after 12 months. Conclusion: The potential benefits of CAD/CAM abutments on soft tissues should be better clarified in future investigations. The usage of customized CAD/CAM abutments in everyday clinical practice should be based on a careful case-by-case evaluation (CRD42020161875). Full article
Show Figures

Figure 1

13 pages, 1743 KiB  
Article
Advancement of Marginal Bone and Soft Tissue Aesthetics for Slope-Configured Implants
by Małgorzata Pietruska and Jan Krzysztof Pietruski
Coatings 2022, 12(9), 1295; https://doi.org/10.3390/coatings12091295 - 2 Sep 2022
Viewed by 2088
Abstract
The aim of the study was to examine changes within the marginal bone and soft tissue aesthetics following placement of implants with a sloped shoulder configuration. Thirty patients with a single missing tooth who showed a palatal/lingual–buccal bone height discrepancy of 2.0–3.0 mm [...] Read more.
The aim of the study was to examine changes within the marginal bone and soft tissue aesthetics following placement of implants with a sloped shoulder configuration. Thirty patients with a single missing tooth who showed a palatal/lingual–buccal bone height discrepancy of 2.0–3.0 mm on CBCT were enrolled in the study. The thickness of buccal and palatal/lingual bone plates 1 and 3 mm apically from the platform; Pink Aesthetic Score and Papilla Index were evaluated. After the implant insertion the mean thickness of the buccal bone plate when measured 1 mm and 3 mm from the shoulder was 1.85 ± 0.68 mm and 1.99 ± 1.05 mm. Six months after the definitive crown delivery, the value of this parameter decreased by 0.32 ± 0.53 mm and 0.15 ± 1.05 mm, respectively. After the temporary crown delivery, the median Pink Aesthetic Score was 5, and it increased to 7.75 six months after the definitive crown delivery. Likewise, the Papilla Index median improved from 1 to 2. After the use of implants with a sloped shoulder configuration, a slight decrease in buccal bone plate thickness can be expected. However, the reduction in the thickness of this bone plate does not have a negative impact on soft tissues, as evidenced by the improvement in indices assessing aesthetics. Full article
Show Figures

Figure 1

8 pages, 245 KiB  
Article
Hybrid Funnel Technique: A Novel Approach for Implant Site Preparation: A Pilot Study
by Luigi Canullo, Roberta Iacono, Eduardo Pires Godoy, Andrea Punzo, Alessio Cavicchia, Francesco Gianfreda and Patrizio Bollero
Dent. J. 2022, 10(9), 157; https://doi.org/10.3390/dj10090157 - 25 Aug 2022
Cited by 6 | Viewed by 2822
Abstract
(1) Background: Different techniques and tools have been developed for implant site preparation. In this clinical scenario, Hybrid Funnel Technique (HFT), a novel osteotomy procedure, has been proposed. (2) Aim: The aim of this retrospective observational study was to consider the different responses [...] Read more.
(1) Background: Different techniques and tools have been developed for implant site preparation. In this clinical scenario, Hybrid Funnel Technique (HFT), a novel osteotomy procedure, has been proposed. (2) Aim: The aim of this retrospective observational study was to consider the different responses to compression of the histological bony compartments (cancellus and cortical). HFT involves the use of multiple drills for the cortical layer preparation and of an osteotome for the osteocompaction of the cancellous bone. (3) Materials and Methods: Following computer-supported implant planning and guided surgery, 10 osteotomies with HFT were performed and 10 implants with the same length and diameter were placed in seven healthy and no daily smoking patients. Periapical X-ray and intraoral photographs were performed at baseline and after 12 months of follow-up to evaluate marginal bone level (MBL) changes and aesthetic results obtained from implant prosthetic rehabilitation. (4) Results: At 1 year of follow-up, 100% of the implants were successfully integrated, MBL change mean value was 0.17 mm ± 0.21. No differences in terms of MBL were noted between thin and thick biotypes. Pink esthetic score (PES) and white esthetic score (WES), assessed one year after definitive restoration placement, were 7.5 ± 2.3 and 8.5 ± 1.1, respectively. (5) Conclusions: Based on the findings of this preliminary clinical study, HFT has led to stability of peri-implant tissues and could represent a reliable technique for surgical preparation of the implant site. Full article
(This article belongs to the Special Issue Dentistry Journal: 10th Anniversary)
17 pages, 18092 KiB  
Article
Sustainable Assignment of Egyptian Ornamental Stones for Interior and Exterior Building Finishes Using the AHP-TOPSIS Technique
by Ahmed M. A. Shohda, Mahrous A. M. Ali, Gaofeng Ren, Jong-Gwan Kim, Ahmed M. Abdo, Wael R. Abdellah and Abbas M. Hassan
Sustainability 2022, 14(4), 2453; https://doi.org/10.3390/su14042453 - 21 Feb 2022
Cited by 10 | Viewed by 3672
Abstract
The ornamental stones industry has grown progressively in Egypt as the demand has increased for Egyptian decorative stones in indoor and outdoor building spaces. Choosing the most suitable ornamental stone for each purpose and taking the right decisions related to aesthetic and practical [...] Read more.
The ornamental stones industry has grown progressively in Egypt as the demand has increased for Egyptian decorative stones in indoor and outdoor building spaces. Choosing the most suitable ornamental stone for each purpose and taking the right decisions related to aesthetic and practical performance can be a challenge causing a lot of confusion for homeowners and contractors. Thus, there is a need to define what decorative style you are trying to achieve in order to properly choose the most suitable decorative stone. In this research, some Egyptian ornamental stones were evaluated by combining the analytic hierarchy process (AHP) and the technique for order preference by similarity to ideal solution (TOPSIS). The optimized AHP–TOPSIS comprehensive decision model was implemented on natural materials relevant to ornaments and the finishing purposes of indoor and outdoor buildings. Ten rock types from four Egyptian sites were studied, examined, and analyzed. According to the quality index scheme, grey granite is an ideal ornamental stone that meets indoor and outdoor purposes. Grey granite and black marble have a performance score (Pi) of 0.78 and 0.71, respectively. Serpentine and pink granite were ranked third with a Pi = 0.68. These results provide stakeholders with strategic indicators to select different natural ornamental stones based on the total points assigned to all rock specifications and costs. Full article
(This article belongs to the Special Issue Synthesis, Design and Environmental Impact of Green Materials)
Show Figures

Figure 1

11 pages, 1815 KiB  
Article
Comparison between Early Loaded Single Implants with Internal Conical Connection or Implants with Transmucosal Neck Design: A Non-Randomized Controlled Trial with 1-Year Clinical, Aesthetics, and Radiographic Evaluation
by Francesco Mattia Ceruso, Irene Ieria, Marco Tallarico, Silvio Mario Meloni, Aurea Immacolata Lumbau, Alessandro Mastroianni, Alessio Zotti and Marco Gargari
Materials 2022, 15(2), 511; https://doi.org/10.3390/ma15020511 - 10 Jan 2022
Cited by 9 | Viewed by 4686
Abstract
To evaluate the implant and prosthetic of two implants with different surfaces and neck design. Enrolled patients received bone level, 12° conical connection implants (Nobel Parallel, Nobel Biocare; NOBEL group) with anodized surface (TiUnite) and roughness of 1.35 μm, or transmucosal implant system [...] Read more.
To evaluate the implant and prosthetic of two implants with different surfaces and neck design. Enrolled patients received bone level, 12° conical connection implants (Nobel Parallel, Nobel Biocare; NOBEL group) with anodized surface (TiUnite) and roughness of 1.35 μm, or transmucosal implant system (Prama, Sweden and Martina; PRAMA group) with convergent collar, ZIrTi surface, and roughness 1.4–1.7 μm. Both implants were made of pure grade IV titanium, with similar diameter and length, chosen according to the dentistry department availability and patient’s request. After early prosthesis delivery, patients were filled for at least one year. Outcome measures were: implant and prosthetic survival and success rates, physiological marginal bone remodeling, periodontal parameters and pink esthetic score (PES). Results: Fifteen patients were allocated and treated in each group. At the one-year follow-up, three patients dropped out, one in the NOBEL group and two in the PRAMA group. During the entire time of investigation, all implants survived and the prostheses were successful. No statistically significant differences were found in term of marginal bone loss, periodontal parameters, and aesthetics (p > 0.05). Conclusion: With the limitations of the present study, both implant systems showed successful clinical results. Finally, many other clinical and surgical variables may influenced marginal bone levels, implant survival, and periodontal parameters. More homogenous clinical trials with larger samples are needed to confirm these preliminary conclusions. Full article
(This article belongs to the Special Issue Dental Implants and Materials (Second Volume))
Show Figures

Figure 1

12 pages, 2263 KiB  
Article
Aesthetic Outcomes of Early Occlusal Loaded SLA Dental Implants with Hydroxyl Ion Modified Surface—A 12 Months Prospective Study
by Maciej Krawiec, Jakub Hadzik, Cyprian Olchowy, Marzena Dominiak and Paweł Kubasiewicz-Ross
Materials 2021, 14(21), 6353; https://doi.org/10.3390/ma14216353 - 24 Oct 2021
Cited by 4 | Viewed by 2450
Abstract
Background: Many efforts have been made recently to arrange a newer, more hydrophilic and more osteoconductive implant surface. One of the possible options in this matter is modification with hydroxyl ion. Materials and Methods: Forty implants with the diameters 3.5 and 4.0 mm [...] Read more.
Background: Many efforts have been made recently to arrange a newer, more hydrophilic and more osteoconductive implant surface. One of the possible options in this matter is modification with hydroxyl ion. Materials and Methods: Forty implants with the diameters 3.5 and 4.0 mm were inserted as a single missing tooth restoration protocol in the frontal aspect of the maxilla. All implants were loaded early in a 4 week period. Prior to and during the surgery, the following indices were considered: height of keratinized tissue, the thickness of soft tissue, and the initial level of bone tissue. After 12 months, the implant and the tissues in its direct vicinity were evaluated once more with the following indices: marginal bone loss (MBL), height of keratinized tissue (HKT), probing pocket depth (PPD), pink and white aesthetics scores (PES, WES), as well as pain sensations combined with the procedure (VAS). All results were related to the diameter of the implant and thickness of periodontal biotype. Results: High aesthetic outcomes were reported regardless of soft tissue thickness and implant diameter. The VAS score was higher for the 4.0 implant group, and the thickness of soft tissue had no influence on VAS. In case of implantation in thin or soft tissue, higher MBL levels were reported (0.26 mm), while in case of a thick phenotype, MBL was 0.06 mm. Conclusions: Hydrophilic surface implants can be used for a protocol of early functional occlusal loading. The initial thickness of soft tissue does not influence aesthetic outcomes and does not raise pain perception, although it may elevate crestal bone resorption. Full article
(This article belongs to the Special Issue Dental Implants and Materials (Second Volume))
Show Figures

Figure 1

16 pages, 6757 KiB  
Data Descriptor
Canadian Dental Patients with a Single-Unit Implant-Supported Restoration in the Aesthetic Region of the Mouth: Qualitative and Quantitative Patient-Reported Outcome Measures (PROMs)
by Kelvin I. Afrashtehfar, Kensuke Igarashi and S. Ross Bryant
Data 2021, 6(8), 90; https://doi.org/10.3390/data6080090 - 11 Aug 2021
Cited by 5 | Viewed by 3302
Abstract
This article contains quantitative and qualitative patient-reported outcome measures (PROMs) collected from nine dental patients, with a single-implant in the maxillary anterior region of the mouth, recruited after obtaining consent documents. The quantitative data were obtained from participants’ demographics, frontal extraoral digital photographs, [...] Read more.
This article contains quantitative and qualitative patient-reported outcome measures (PROMs) collected from nine dental patients, with a single-implant in the maxillary anterior region of the mouth, recruited after obtaining consent documents. The quantitative data were obtained from participants’ demographics, frontal extraoral digital photographs, intraoral scans (IOS) of the maxillary arch, and self-administered questionnaires (where patients judged the overall, appearance, function, and comfort of their single-implant-supported crowns). Objective single-implant aesthetic index mean scores (Pink Esthetic Score/White Esthetic Score [PES/WES]) were obtained after two experienced calibrated clinicians analyzed the photographs and the three-dimensional models generated from the IOS. The self-administered questionnaires used a visual analogue scale (VAS) to obtain the patients’ subjective perceptions. The qualitative data were obtained from in-depth, semi-structured one-to-one interviews. The transcriptions from audio-recorded interview data were managed and coded, with the aid of a Computer-Assisted Qualitative Data Analysis Software (CAQDAS). These data were stored in a public repository that can be easily downloaded from a Mendeley data repository (DOI: 10.17632/sv8t6tkvjv.1). Full article
Show Figures

Figure 1

8 pages, 1215 KiB  
Article
Aesthetic Outcomes and Peri-Implant Health of Angled Screw Retained Implant Restorations Compared with Cement Retained Crowns: Medium Term Follow-Up
by Livia Nastri, Ludovica Nucci, Vincenzo Grassia and Rino Miraldi
J. Funct. Biomater. 2021, 12(2), 35; https://doi.org/10.3390/jfb12020035 - 16 May 2021
Cited by 11 | Viewed by 4016
Abstract
Single tooth implant restorations in the aesthetic area are a demanding challenge. If a complete osseointegration is mandatory, the final result has to result in a higher standard of biomimetic and soft tissue health among natural teeth. This outcome is traditionally pursued by [...] Read more.
Single tooth implant restorations in the aesthetic area are a demanding challenge. If a complete osseointegration is mandatory, the final result has to result in a higher standard of biomimetic and soft tissue health among natural teeth. This outcome is traditionally pursued by cementing crowns over individualized abutments. However, in recent years, the need for controlling peri-implant health and the preference towards a retrievable solution has led to an increase in screw-retained crowns, which is not always applicable when the implant axis is not ideal. In the aesthetic area, the use of a novel technical solution represented by the angled screw channel (ASC) of the abutment has been proposed in order to match the advantages of the screwed solution with the aesthetic demands. The aim of this study was to compare ASC crowns to cemented crowns (CC) in single implant restorations using the white esthetic score (WES) and pink esthetic score (PES) at the crown delivery and at a follow-up of a minimum of 2 years. Peri-implant health and marginal bone loss (MBL) were also evaluated. The mean follow-up was 44.3 months, with a mean MBL of 0.22 mm in the ASC group and 0.29 mm in the CC group. The total WES/PES score was 16.6 for ASC, compared with 17.3 for CC at baseline, and 16.2 and 17.1, respectively, at follow-up. Both of the groups reached a high WES/PES, and this was maintained over time, without signs of peri-implant diseases or bone loss, regardless of the choice of connection. In conclusion, ASC can be adopted in cases where the implant axis is not ideal, with aesthetic and functional results that are comparable to implants restored by cemented crowns. Full article
(This article belongs to the Special Issue Advanced Functional Biomaterials for Dental Implants)
Show Figures

Figure 1

9 pages, 1083 KiB  
Article
A Randomized Clinical Trial Comparing Immediate Loading and Delayed Loading of Single-Tooth Implants: 5-Year Results
by Björn Gjelvold, Jenö Kisch and Bruno R. Chrcanovic
J. Clin. Med. 2021, 10(5), 1077; https://doi.org/10.3390/jcm10051077 - 5 Mar 2021
Cited by 15 | Viewed by 3316
Abstract
The aim of this prospective randomized clinical study was to compare the clinical treatment outcome for single dental implants submitted to either immediate loading (IL) or delayed loading (DL) after 5 years of follow-up. Fifty patients with a missing maxillary tooth (15–25) were [...] Read more.
The aim of this prospective randomized clinical study was to compare the clinical treatment outcome for single dental implants submitted to either immediate loading (IL) or delayed loading (DL) after 5 years of follow-up. Fifty patients with a missing maxillary tooth (15–25) were randomly allocated to either the IL or DL. The treatment procedures included implant installation in healed sites, temporary screw-retained crown and replacement with a permanent single implant crown. The two groups were evaluated with regard to implant survival, marginal bone level, papillae index, pink and white esthetic score (PES, WES). At the 5-year follow-up the implant survival rate was 100% and 95.8% for IL and DL, respectively. Implant success rate was 91.7% and 83.3% for IL and DL, respectively. The mean ± SD marginal bone loss for IL and DL was −0.50 ± 0.73 mm and −0.54 ± 0.65 mm, respectively. (p = 0.782). Statistically significant less marginal bone loss was found non-smokers (p = 0.021). No statistically significant differences were found for IL and DL concerning papillae index PES and WES after 5 years. This study suggests that implant-supported single crowns in the maxillary aesthetic zone can present similar results with respect to either IL or DL after 5 years. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

15 pages, 6915 KiB  
Article
Clinical Evaluation of the Nasopalatine Canal in Implant-Prosthetic Treatment: A Pilot Study
by Enrique Fernández Bodereau, Viviana Yolanda Flores, Pablo Naldini, Daniel Torassa and Patricia Tortolini
Dent. J. 2020, 8(2), 30; https://doi.org/10.3390/dj8020030 - 1 Apr 2020
Cited by 10 | Viewed by 6100
Abstract
Implant-prosthetic rehabilitation of missing teeth in the anterior maxilla is often challenging due to ongoing bone resorption and remodeling events and may require regeneration procedures involving the nasopalatine canal (NPC). We describe a surgical approach with a block graft in relation to the [...] Read more.
Implant-prosthetic rehabilitation of missing teeth in the anterior maxilla is often challenging due to ongoing bone resorption and remodeling events and may require regeneration procedures involving the nasopalatine canal (NPC). We describe a surgical approach with a block graft in relation to the NPC and evaluate clinical performance, sensory perception, and aesthetic result of the implant-prosthetic treatment over a two- to nine-year (mean: 3.5 years) follow-up. Ten implants (six in the right central incisor and four in the left central incisor) were, respectively, placed in 10 consecutive patients with bone defects affecting the NPC and unfavorable widening of the incisive foramen. Treatment stages included: (1) Diagnosis: evaluation of clinical-aesthetic parameters using Cone Beam Computed Tomography; (2) Surgery: block graft placement by palatine and incisal with simultaneous guided bone regeneration, and late (6–10 months) implant placement; (3) Prosthetics: placement of a screw-retained crown (torque of 32 N/cm). At treatment initiation, all the NPCs evaluated in our study were free of pathologies. Treatment evaluation included bone crest thickness, neurosensory status, patients’ treatment perception, and pink and white aesthetic scores (PES/WES). Pre-surgery, anterior ridge thickness at the level of the incisive foramen was (mean ± SD) 3.5 ± 2 mm, 5.4 ± 1.5 mm, and 6.1 ± 1.9 mm at heights of 4, 8, and 14 mm apical to the marginal bone crest, respectively. Post-treatment values were, respectively, 10.1 ± 2.0 mm, 10.5 ± 1.0 mm, and 13.4 ± 3.0 mm. The perception of treatment with the aesthetic pink and white indices (PES/WES) was an average of 7.5 and 7 points, respectively, out of a total of 10 each index, with a recovery of 100% of the neurosensory perception of the area. We propose that bone augmentation using block and particulate graft material can compensate for anatomical variations in the NPC, optimize implant’s three-dimensional positioning and improve facial contour, providing tissue and implant stability and good aesthetic outcomes. Full article
(This article belongs to the Special Issue Soft Tissue Integration and Osseointegration around Dental Implants)
Show Figures

Figure 1

10 pages, 4462 KiB  
Article
Effect of Simultaneous Immediate Implant Placement and Guided Bone Reconstruction with Ultra-Fine Titanium Mesh Membranes on Radiographic and Clinical Parameters after 18 Months of Loading
by Marco Tallarico, Francesco Mattia Ceruso, Leonardo Muzzi, Silvio Mario Meloni, Yong-Jin Kim, Marco Gargari and Matteo Martinolli
Materials 2019, 12(10), 1710; https://doi.org/10.3390/ma12101710 - 26 May 2019
Cited by 26 | Viewed by 5692
Abstract
Background: The aim of the present prospective case series study was to evaluate the implant and prosthetic survival rates, complications and marginal bone loss using ultra-fine titanium mesh membrane with simultaneous implant placement, to provide space maintenance mandatory for guided bone reconstruction of [...] Read more.
Background: The aim of the present prospective case series study was to evaluate the implant and prosthetic survival rates, complications and marginal bone loss using ultra-fine titanium mesh membrane with simultaneous implant placement, to provide space maintenance mandatory for guided bone reconstruction of alveolar bone defects. Materials and Methods: patients were recruited and treated at a private clinic in Rome, Italy, between March 2016 and October 2017. Self-tapping tapered implants were placed through a computer-guided template-assisted approach. Autogenous bone was placed alone over the exposed implant surface, then mixed with inorganic bovine bone material. Finally, the membrane was connected and shaped in order to securely enclose the graft area, and the healing cap was connected and screwed onto the height connector. Outcome measures were: implant and prosthetic failure, biological and mechanical complications, marginal and volumetric bone level changes, esthetic evaluation performed according to the pink aesthetic score (PES). Results: in total, seven patients (five women, two men) with a mean age of 52.7 ± 20.3 years (range: 27–71) received 10 self-tapping tapered implants and simultaneous guided bone regeneration with ultra-fine titanium mesh membranes. No implants and no prostheses failed during the entire follow-up period. One slightly membrane exposure was observed one month after implant placement in one patient. The mean marginal bone loss (MBL) at implant loading was 0.13 ± 0.09 mm (95% CI 0.08–0.19). At the 18-month follow-up examination, the mean MBL was 0.28 ± 0.33 mm (95% CI 0.07–0.50) The difference was not statistically significant (0.15 ± 0.31; 95% CI 0.05–0.35; P = 0.1888). The mean horizontal alveolar ridge width was 3.72 ± 1.08 mm (95% CI 3.22–4.22 mm). At the II-stage surgery, the mean bone width was 8.79 ± 0.98 mm (95% CI 8.51–9.07 mm). The mean bone gain was 5.06 ± 1.13 mm (95% CI 4.68–5.44 mm; P = 0.000). The mean volume of the grafted bone calculated using the superimposition technique was 0.99 ± 0.38 CC (95% CI 0.75–1.23 CC). The mean PES at implant loading was 8.2 ± 0.8 mm (95% CI 7.7–8.7). At the 18-month follow-up examination, the mean PES was 12.0 ± 0.7 mm (95% CI 11.5–12.5) The difference was statistically significant (3.8 ± 0.4; 95% CI 3.5–4.1; P = 0.0000); Conclusion: with the limitation of the present prospective study, the guided bone reconstruction using an ultra-fine titanium mesh membrane with simultaneous implant placement seems to provide good and stable results in implant/prosthesis success. Further research with a longer follow-up and a higher sample size are needed to confirm the results from this preliminary report. Full article
(This article belongs to the Special Issue Dental Implants and Materials)
Show Figures

Figure 1

7 pages, 10379 KiB  
Case Report
Soft Tissue Contour Impression with Analogic or Digital Work Flow: A Case Report
by Luigi Canullo, Andrea Di Domenico, Fabio Marinotti, Maria Menini and Paolo Pesce
Int. J. Environ. Res. Public Health 2018, 15(12), 2623; https://doi.org/10.3390/ijerph15122623 - 23 Nov 2018
Cited by 11 | Viewed by 5004
Abstract
Purpose: Transferring precise information to the dental laboratory is one of the key factors to achieving clinical success. The aim of the present study was to describe classical and digital work-flows used to rehabilitate an implant with a convergent collar in the aesthetic [...] Read more.
Purpose: Transferring precise information to the dental laboratory is one of the key factors to achieving clinical success. The aim of the present study was to describe classical and digital work-flows used to rehabilitate an implant with a convergent collar in the aesthetic zone following the BOPT (biologically oriented preparation technique) approach and to report the three years follow-up outcomes of two patients rehabilitated following such procedures. Materials and methods: Two central incisors of two different patients were rehabilitated with a tissue-level implant with a convergent collar and, after a provisional and healing phase, one implant was “impressed” using a classical workflow and one using a digital one. The primary outcome measured was the mean bone loss. An intraoral radiograph was taken at crown delivery and at the three years follow-up visit. Secondary Esthetic outcomes pre-op and post-op were evaluated using the PES (pink esthetic score). Results: At the three years follow-up visit, radiographic analysis showed no signs of bone resorption. For the analogic procedure, the pre-and post-op PES scores were 8, whereas for the digital procedure the pre-op PES score was 4 and a post-op score of 9 was obtained. Conclusions: classical and digital work flows succeeded in giving precise and complete anatomical information of implant position, including the soft tissue contour. Minimum bone loss and an esthetic success were obtained in both procedures. Full article
(This article belongs to the Special Issue Digital Dentistry: The Evolution of Dental Care)
Show Figures

Figure 1

Back to TopTop