Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (12)

Search Parameters:
Keywords = mixed neutron-gamma radiation

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
19 pages, 1951 KiB  
Article
FSL-1 Pre-Administration Protects Radiation-Induced Hematopoietic Organs Through the Modulation of the TLR Signaling Pathway
by Venkateshwara Rao Dronamraju, Gregory P. Holmes-Hampton, Emily Gu, Vidya P. Kumar and Sanchita P. Ghosh
Int. J. Mol. Sci. 2025, 26(11), 5303; https://doi.org/10.3390/ijms26115303 - 31 May 2025
Viewed by 510
Abstract
Substantial progress has been made in the development of radiation countermeasures, resulting in the recent approval of several mitigators; however, there has yet to be an approved prophylactic radioprotectant. Research on countermeasure performance in mixed neutron and gamma radiation fields has also been [...] Read more.
Substantial progress has been made in the development of radiation countermeasures, resulting in the recent approval of several mitigators; however, there has yet to be an approved prophylactic radioprotectant. Research on countermeasure performance in mixed neutron and gamma radiation fields has also been scarce. Fibroblast-stimulating lipopeptide (FSL-1) is a novel synthetic agonist for toll-like receptor 2/6. In previous studies, the administration of FSL-1 before and after gamma radiation significantly improved survival outcomes for mice through the activation of the NF-κB pathway. In the current study, we tested FSL-1’s radioprotective abilities in a mixed radiation field that models one produced by a nuclear detonation in 11–14-week-old C57BL/6 male and female mice. We demonstrate that a single dose of 1.5 mg/kg of FSL-1 administered 12 h prior to 65% neutron 35% gamma mixed-field (MF) irradiation enhances survival, accelerates recovery of hematopoietic cell and stem cell populations, reduces inflammation, and protects innate immune function in mice. FSL-1’s ability to recover blood and protect immune functions is important in countering the high rate of incidence of sepsis caused by MF radiation’s damaging effects. These results demonstrate that FSL-1 is a promising prophylactic countermeasure where exposure to MF radiation is anticipated. Full article
Show Figures

Figure 1

17 pages, 23301 KiB  
Article
A 3D Dual-Particle Imaging Algorithm for Multiple Imagers
by Dhruv Garg, Ricardo Lopez, Oskari Pakari, Shaun D. Clarke and Sara A. Pozzi
J. Nucl. Eng. 2024, 5(4), 584-600; https://doi.org/10.3390/jne5040036 - 20 Dec 2024
Viewed by 1194
Abstract
The ability to localize and image radiation sources has found use in various applications for nuclear nonproliferation practices, specifically in treaty verification, nuclear safeguards, and homeland security. Technologies that are capable of angular radiation imaging have been prevalent for years and, recently, 3D [...] Read more.
The ability to localize and image radiation sources has found use in various applications for nuclear nonproliferation practices, specifically in treaty verification, nuclear safeguards, and homeland security. Technologies that are capable of angular radiation imaging have been prevalent for years and, recently, 3D imaging technologies making use of emerging media like mixed reality have been rapidly developing and gaining popularity. Modern imaging techniques typically use a Compton camera to record coincident events and reconstruct the incident directional information of a gamma ray-emitting radiation source. However, Compton cameras are limited as they cannot obtain accurate source depth information when used for simple back projection imaging. Neutron scatter cameras are a complementary imaging technique that use double elastic scatters but also have their own limitations. This work presents a framework for multiple scatter-based particle imagers to construct 3D images and to localize a radiation source using gamma rays or fast neutrons. Specifically, localization is achieved by accounting for the position of the imagers. The imaging algorithm was validated using experimental data, measuring a 252Cf source. A three-dimensional representation of the imaging data provides a more intuitive and informative depiction of source positions and can aid in scenarios with complex environmental geometries such as when sources are in containers. Full article
Show Figures

Figure 1

16 pages, 2045 KiB  
Article
An Optimized SVR Algorithm for Pulse Pile-Up Correction in Pulse Shape Discrimination
by Xianghe Liu, Bingqi Liu, Mingzhe Liu, Yufeng Tang, Haonan Li and Yao Huang
Sensors 2024, 24(23), 7545; https://doi.org/10.3390/s24237545 - 26 Nov 2024
Viewed by 1075
Abstract
Pulse pile-up presents a significant challenge in nuclear radiation measurements, particularly in neutron-gamma pulse shape discrimination, as it causes pulse distortion and diminishes identification accuracy. To address this, we propose an optimized Support Vector Regression (SVR) algorithm for correcting pulse pile-up. Initially, the [...] Read more.
Pulse pile-up presents a significant challenge in nuclear radiation measurements, particularly in neutron-gamma pulse shape discrimination, as it causes pulse distortion and diminishes identification accuracy. To address this, we propose an optimized Support Vector Regression (SVR) algorithm for correcting pulse pile-up. Initially, the Dung Beetle Optimizer (DBO) and Whale Optimization Algorithm (WOA) are integrated to refine the correction process, with performance evaluated using charge comparison methods (CCM) for pulse shape discrimination. Leveraging prior knowledge from simulated data, we further analyze the relationships between various types of pulse pile-ups, including their combinations, inter-peak distances, and the accuracy of corrections. Extensive experiments conducted in a mixed neutron-gamma radiation field using plastic scintillators demonstrate that the proposed method effectively corrects pulse pile-up and accurately discriminates between neutron and gamma. Moreover, our approach significantly improves the fidelity of pulse shape discrimination and enhances the overall reliability of radiation detection systems in high-interference environments. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

15 pages, 4020 KiB  
Article
Transition Metal Borides for All-in-One Radiation Shielding
by Celal Avcıoğlu and Suna Avcıoğlu
Materials 2023, 16(19), 6496; https://doi.org/10.3390/ma16196496 - 29 Sep 2023
Cited by 10 | Viewed by 2522
Abstract
All-in-one radiation shielding is an emerging concept in developing new-generation radiation protection materials since various forms of ionizing radiation, such as neutrons and gamma rays, can occur simultaneously. In this study, we examine the ability of transition metal borides to attenuate both photon [...] Read more.
All-in-one radiation shielding is an emerging concept in developing new-generation radiation protection materials since various forms of ionizing radiation, such as neutrons and gamma rays, can occur simultaneously. In this study, we examine the ability of transition metal borides to attenuate both photon and particle radiation. Specifically, fourteen different transition metal borides (including inner transition metal borides) are selected for examination based on their thermodynamic stabilities, molecular weights, and neutron capture cross-sections of the elements they contain. Radiation shielding characteristics of the transition metal borides are computationally investigated using Phy-X/PSD, EpiXS and NGCal software. The gamma-ray shielding capabilities of the transition metal borides are evaluated in terms of the mass attenuation coefficient (μm), the linear attenuation coefficient (µ), the effective atomic number (Zeff), the half-value layer (HVL), the tenth-value layer (TVL), and the mean free path (MFP). The mass and linear attenuation factors are identified for thermal and fast neutrons at energies of 0.025 eV and 4 MeV, respectively. Moreover, the fast neutron removal cross-sections (∑R) of the transition metal borides are calculated to assess their neutron shielding abilities. The results revealed that borides of transition metals with a high atomic number, such as Re, W, and Ta, possess outstanding gamma shielding performance. At 4 MeV photon energy, the half-value layers of ReB2 and WB2 compounds were found as 1.38 cm and 1.43 cm, respectively. Most notably, these HVL values are lower than the HVL value of toxic Pb (1.45 cm at 4 MeV), which is one of the conventional radiation shielding materials. On the other hand, SmB6 and DyB6 demonstrated exceptional neutron attenuation for thermal and fast neutrons due to the high neutron capture cross-sections of Sm, Dy, and B. The outcomes of this study reveal that transition metal borides can be suitable candidates for shielding against mixed neutron and gamma radiation. Full article
(This article belongs to the Special Issue Development of Boron-Based Materials)
Show Figures

Figure 1

16 pages, 4622 KiB  
Article
Hungarian Fine-to-Coarse Aggregate, a Possible Constituent of Near-Vessel Structural Concrete of Nuclear Power Plants
by Katalin Gméling, Veronika Szilágyi, Ildikó Harsányi and László Szentmiklósi
Materials 2023, 16(9), 3520; https://doi.org/10.3390/ma16093520 - 4 May 2023
Cited by 2 | Viewed by 1634
Abstract
Significant gravel mines, representative of four regions of Hungary (northeast, central, northwest, and southwest) were systematically sampled to characterize their sand and pebbles as potential constituents of nuclear-grade concrete. The samples were analysed for their elemental compositions as a function of the mining [...] Read more.
Significant gravel mines, representative of four regions of Hungary (northeast, central, northwest, and southwest) were systematically sampled to characterize their sand and pebbles as potential constituents of nuclear-grade concrete. The samples were analysed for their elemental compositions as a function of the mining locality and grain size, using two complementary neutron-based analytical techniques, prompt gamma activation analysis (PGAA) and neutron activation analysis (NAA). The combined analysis resulted in reliable mass fractions for over thirty elements that could be used to assess the radiation shielding and activation properties of the resulting concrete, essential in nuclear applications, by means of computer simulations. The studied aggregates are proven to be appropriate constituents for biological shielding at radiological centres, NPPs, and at nuclear research installations, even in mixed neutron/gamma radiation fields. The elemental compositions also revealed geochemical differences between the sedimentologically different regions. Full article
(This article belongs to the Special Issue Advances in Sustainable Civil Engineering Materials)
Show Figures

Graphical abstract

15 pages, 2522 KiB  
Article
Shielding Capability Research on Composite Base Materials in Hybrid Neutron-Gamma Mixed Radiation Fields
by Ming Xiao, Qingao Qin, Xin He, Fei Li and Xiaobo Wang
Materials 2023, 16(5), 2084; https://doi.org/10.3390/ma16052084 - 3 Mar 2023
Cited by 10 | Viewed by 3001
Abstract
The 16N monitoring system operates in a mixed neutron-gamma radiation field and is subject to high background radiation, thus triggering instability in the 16N monitoring system measurement data. Due to its property of actual physical process simulation, the Monte Carlo method [...] Read more.
The 16N monitoring system operates in a mixed neutron-gamma radiation field and is subject to high background radiation, thus triggering instability in the 16N monitoring system measurement data. Due to its property of actual physical process simulation, the Monte Carlo method was adopted to establish the model of the 16N monitoring system and design a structure-functionally integrated shield to realize neutron-gamma mixed radiation shielding. First, the optimal shielding layer with a thickness of 4 cm was determined in this working environment, which had a significant shielding effect on the background radiation and improved the measurement of the characteristic energy spectrum and the shielding effect on neutrons was better than gamma shielding with the increase in the shield thickness. Then, functional fillers such as B, Gd, W, and Pb were added to the matrix to compare the shielding rates of three matrix materials of polyethylene, epoxy resin, and 6061 aluminum alloy at 1 MeV neutron and gamma energy. The shielding performance of epoxy resin as the matrix material was better than that of the aluminum alloy and polyethylene, and the shielding rate of boron-containing epoxy resin was 44.8%. The γ-ray mass attenuation coefficients of lead and tungsten in the three matrix materials were simulated to determine the best material for the gamma shielding performance. Finally, the optimal materials for neutron shielding and gamma shielding were combined, and the shielding performance of single-layer shielding and double-layer shielding in mixed radiation field was compared. The optimal shielding material-boron-containing epoxy resin was determined as the shielding layer of the 16N monitoring system to realize the integration of structure and function, which provides a theoretical basis for the selection of shielding materials in a special working environment. Full article
Show Figures

Figure 1

19 pages, 5749 KiB  
Article
Investigating the Effect of Gamma and Neutron Irradiation on Portland Cement Provided with Waste Silicate Glass
by Mohanad S. Eid, Ibrahim I. Bondouk, Hosam M. Saleh, Khaled M. Omar and Hassan M. Diab
Sustainability 2023, 15(1), 763; https://doi.org/10.3390/su15010763 - 31 Dec 2022
Cited by 16 | Viewed by 2604
Abstract
In this study, samples of commercial Portland cement mixed with 30% weight of crushed waste silicate glass were prepared in the shape of well-dried cylinders. Then, their physical and mechanical properties were investigated for two types of samples: samples without exposure and samples [...] Read more.
In this study, samples of commercial Portland cement mixed with 30% weight of crushed waste silicate glass were prepared in the shape of well-dried cylinders. Then, their physical and mechanical properties were investigated for two types of samples: samples without exposure and samples with exposure to gamma-ray and neutron irradiation. A notable deterioration of the physical properties of the irradiated samples relative to the non-irradiated ones was recorded. All the spectroscopic analyses were performed for the samples with exposure and without exposure to gamma-ray and neutron irradiation. The XRD emerging peaks of irradiated samples were studied to estimate the presence and stabilities of major peaks indicating the presence of the main compositions of cement with the amorphous nature of glass. FT-IR transmittance spectra were identified and the bonds were located close to those of identical glasses. Moreover, SEM images and EDX analysis were conducted on the two types of composite samples (without exposure and with exposure to gamma and neutron irradiation) to specify the change in the physical appearance and the chemical composition after irradiation. The attenuation parameters were computed theoretically with the assistance of Phy-X/PSD software to evaluate the gamma-ray and neutron shielding properties by defining the composition and the density of the samples. The irradiation was found to have a negative impact on the shielding ability of the prepared samples where there was an over-reduction in the parameters calculated with the probability that the damage may increase with longer exposure to the radiation. Full article
(This article belongs to the Section Sustainable Materials)
Show Figures

Figure 1

11 pages, 2553 KiB  
Article
Characterization of Thermoluminescent Dosimeters for Neutron Dosimetry at High Altitudes
by Vittoria D’Avino, Fabrizio Ambrosino, Roberto Bedogni, Abner Ivan C. Campoy, Giuseppe La Verde, Silvia Vernetto, Carlo Francesco Vigorito and Mariagabriella Pugliese
Sensors 2022, 22(15), 5721; https://doi.org/10.3390/s22155721 - 30 Jul 2022
Cited by 8 | Viewed by 3222
Abstract
Neutrons constitute a significant component of the secondary cosmic rays and are one of the most important contributors to natural cosmic ray radiation background dose. The study of the cosmic ray neutrons’ contribution to the dose equivalent received by humans is an interesting [...] Read more.
Neutrons constitute a significant component of the secondary cosmic rays and are one of the most important contributors to natural cosmic ray radiation background dose. The study of the cosmic ray neutrons’ contribution to the dose equivalent received by humans is an interesting and challenging task for the scientific community. In addition, international regulations demand assessing the biological risk due to radiation exposure for both workers and the general population. Because the dose rate due to cosmic radiation increases significantly with altitude, the objective of this work was to characterize the thermoluminescent dosimeter (TLDs) from the perspective of exposing them at high altitudes for longtime neutron dose monitoring. The pair of TLD-700 and TLD-600 is amply used to obtain the information on gamma and neutron dose in mixed neutron-gamma fields due to the present difference in 6Li isotope concentration. A thermoluminescence dosimeter system based on pair of TLD-600/700 was characterized to enable it for neutron dosimetry in the thermal energy range. The system was calibrated in terms of neutron ambient dose equivalent in an experimental setup using a 241Am-B radionuclide neutron source coated by a moderator material, polyethylene, creating a thermalized neutron field. Afterward, the pair of TLD-600/700 was exposed at the CERN-EU High-Energy Reference Field (CERF) facility in Geneva, which delivers a neutron field with a spectrum similar to that of secondary cosmic rays. The dosimetric system provided a dose value comparable with the calculated one demonstrating a good performance for neutron dosimetry. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

7 pages, 373 KiB  
Article
Response to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN
by Jaroslav Jánský, Jiří Janda, Michal Košťál, Zdeněk Matěj, Tomáš Bílý, Věra Mazánková, Filip Mravec and František Cvachovec
Quantum Beam Sci. 2022, 6(2), 18; https://doi.org/10.3390/qubs6020018 - 12 May 2022
Cited by 4 | Viewed by 3176
Abstract
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component [...] Read more.
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep1.00(1exp(0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep1.00(1exp(0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination. Full article
(This article belongs to the Special Issue New Trends in Neutron Instrumentation, 2nd Edition)
Show Figures

Figure 1

19 pages, 3501 KiB  
Article
Formwork Pressure of a Heavyweight Self-Compacting Concrete Mix
by Michał A. Glinicki, Jacek Gołaszewski and Grzegorz Cygan
Materials 2021, 14(6), 1549; https://doi.org/10.3390/ma14061549 - 22 Mar 2021
Cited by 16 | Viewed by 3408
Abstract
High-fluidity and self-compacting concrete (SCC) mixes were developed using special aggregates for radiation-shielding concrete. The special aggregates comprised heavyweight and hydrous aggregates (crushed magnetite, crushed serpentine, and their mixtures), which were selected to provide an enhanced attenuation of gamma and neutron radiation, respectively. [...] Read more.
High-fluidity and self-compacting concrete (SCC) mixes were developed using special aggregates for radiation-shielding concrete. The special aggregates comprised heavyweight and hydrous aggregates (crushed magnetite, crushed serpentine, and their mixtures), which were selected to provide an enhanced attenuation of gamma and neutron radiation, respectively. For the mixed concrete design with a bulk density of up to 3570 kg/m3, two cement types were used: Portland cement CEM I and slag cement CEM III/A. The basic properties of the fresh self-compacting concrete were evaluated and the lateral formwork pressure exerted by the freshly mixed self-compacting concrete was measured and analyzed. An original test setup was developed for the determination of the lateral pressure on the square column formwork with pressure measurements carried out using six strain gauge pressure transducers, which was adequate for heavyweight concrete mixture testing. Self-compacting concrete mixtures containing a magnetite aggregate or blends of serpentine and magnetite aggregates with a slump flow of at least 550 mm were developed. The lateral pressure on the formwork was directly proportional to the density of the self-compacting heavyweight concrete mixes. The maximum values of the lateral pressure recorded in the test at a casting speed of 1.5 m/h did not exceed 27 kPa and 55% of hydrostatic pressure. Concrete mixtures with basalt, magnetite, and magnetite/serpentine blended aggregates were found to develop sufficient shear strength for proper stability during casting. Full article
(This article belongs to the Special Issue Concrete Technology and Mechanical Properties of Concretes)
Show Figures

Figure 1

14 pages, 2809 KiB  
Article
Thermal Neutron Relative Biological Effectiveness Factors for Boron Neutron Capture Therapy from In Vitro Irradiations
by María Pedrosa-Rivera, Javier Praena, Ignacio Porras, Manuel P. Sabariego, Ulli Köster, Michael Haertlein, V. Trevor Forsyth, José C. Ramírez, Clara Jover, Daniel Jimena, Juan L. Osorio, Patricia Álvarez, Carmen Ruiz-Ruiz and María J. Ruiz-Magaña
Cells 2020, 9(10), 2144; https://doi.org/10.3390/cells9102144 - 23 Sep 2020
Cited by 6 | Viewed by 3902
Abstract
The experimental determination of the relative biological effectiveness of thermal neutron factors is fundamental in Boron Neutron Capture Therapy. The present values have been obtained while using mixed beams that consist of both neutrons and photons of various energies. A common weighting factor [...] Read more.
The experimental determination of the relative biological effectiveness of thermal neutron factors is fundamental in Boron Neutron Capture Therapy. The present values have been obtained while using mixed beams that consist of both neutrons and photons of various energies. A common weighting factor has been used for both thermal and fast neutron doses, although such an approach has been questioned. At the nuclear reactor of the Institut Laue-Langevin a pure low-energy neutron beam has been used to determine thermal neutron relative biological effectiveness factors. Different cancer cell lines, which correspond to glioblastoma, melanoma, and head and neck squamous cell carcinoma, and non-tumor cell lines (lung fibroblast and embryonic kidney), have been irradiated while using an experimental arrangement designed to minimize neutron-induced secondary gamma radiation. Additionally, the cells were irradiated with photons at a medical linear accelerator, providing reference data for comparison with that from neutron irradiation. The survival and proliferation were studied after irradiation, yielding the Relative Biological Effectiveness that corresponds to the damage of thermal neutrons for the different tissue types. Full article
(This article belongs to the Special Issue Biology of Boron Neutron Capture Therapy (BNCT))
Show Figures

Figure 1

20 pages, 5813 KiB  
Article
Bone Marrow Endothelial Cells Influence Function and Phenotype of Hematopoietic Stem and Progenitor Cells after Mixed Neutron/Gamma Radiation
by Lynnette Cary, Daniel Noutai, Rudolph Salber, Opeyemi Fadiyimu, Arthur Gross, Graca Almeida-Porada, Yared Kidane and Mark Whitnall
Int. J. Mol. Sci. 2019, 20(7), 1795; https://doi.org/10.3390/ijms20071795 - 11 Apr 2019
Cited by 11 | Viewed by 5165
Abstract
The bone marrow (BM) microenvironment plays a crucial role in the maintenance and regeneration of hematopoietic stem (HSC) and progenitor cells (HSPC). In particular, the vascular niche is responsible for regulating HSC maintenance, differentiation, and migration of cells in and out of the [...] Read more.
The bone marrow (BM) microenvironment plays a crucial role in the maintenance and regeneration of hematopoietic stem (HSC) and progenitor cells (HSPC). In particular, the vascular niche is responsible for regulating HSC maintenance, differentiation, and migration of cells in and out of the BM. Damage to this niche upon exposure to ionizing radiation, whether accidental or as a result of therapy, can contribute to delays in HSC recovery and/or function. The ability of BM derived-endothelial cells (BMEC) to alter and/or protect HSPC after exposure to ionizing radiation was investigated. Our data show that exposure of BMEC to ionizing radiation resulted in alterations in Akt signaling, increased expression of PARP-1, IL6, and MCP-1, and decreased expression of MMP1 and MMP9. In addition, global analysis of gene expression of HSC and BMEC in response to mixed neutron/gamma field (MF) radiation identified 60 genes whose expression was altered after radiation in both cell types, suggesting that a subset of genes is commonly affected by this type of radiation. Focused gene analysis by RT-PCR revealed two categories of BMEC alterations: (a) a subset of genes whose expression was altered in response to radiation, with no additional effect observed during coculture with HSPC, and (b) a subset of genes upregulated in response to radiation, and altered when cocultured with HSPC. Coculture of BMEC with CD34+ HSPC induced HSPC proliferation, and improved BM function after MF radiation. Nonirradiated HSPC exhibited reduced CD34 expression over time, but when irradiated, they maintained higher CD34 expression. Nonirradiated HSPC cocultured with nonirradiated BMEC expressed lower levels of CD34 expression compared to nonirradiated alone. These data characterize the role of each cell type in response to MF radiation and demonstrate the interdependence of each cell’s response to ionizing radiation. The identified genes modulated by radiation and coculture provide guidance for future experiments to test hypotheses concerning specific factors mediating the beneficial effects of BMEC on HSPC. This information will prove useful in the search for medical countermeasures to radiation-induced hematopoietic injury. Full article
(This article belongs to the Collection Radiation Toxicity in Cells)
Show Figures

Figure 1

Back to TopTop