Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (595)

Search Parameters:
Keywords = knee movement

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2388 KiB  
Article
Evaluating Lumbar Biomechanics for Work-Related Musculoskeletal Disorders at Varying Working Heights During Wall Construction Tasks
by Md. Sumon Rahman, Tatsuru Yazaki, Takanori Chihara and Jiro Sakamoto
Biomechanics 2025, 5(3), 58; https://doi.org/10.3390/biomechanics5030058 (registering DOI) - 3 Aug 2025
Abstract
Objectives: The aim of this study was to evaluate the impact of four working heights on lumbar biomechanics during wall construction tasks, focusing on work-related musculoskeletal disorders (WMSDs). Methods: Fifteen young male participants performed simulated mortar-spreading and bricklaying tasks while actual [...] Read more.
Objectives: The aim of this study was to evaluate the impact of four working heights on lumbar biomechanics during wall construction tasks, focusing on work-related musculoskeletal disorders (WMSDs). Methods: Fifteen young male participants performed simulated mortar-spreading and bricklaying tasks while actual body movements were recorded using Inertial Measurement Unit (IMU) sensors. Muscle activities of the lumbar erector spinae (ES), quadratus lumborum (QL), multifidus (MF), gluteus maximus (GM), and iliopsoas (IL) were estimated using a 3D musculoskeletal (MSK) model and measured via surface electromyography (sEMG). The analysis of variance (ANOVA) test was conducted to identify the significant differences in muscle activities across four working heights (i.e., foot, knee, waist, and shoulder). Results: Findings showed that working at foot-level height resulted in the highest muscle activity (7.6% to 40.6% increase), particularly in the ES and QL muscles, indicating an increased risk of WMSDs. The activities of the ES, MF, and GM muscles were statistically significant across both tasks and all working heights (p < 0.01). Conclusions: Both MSK and sEMG analyses indicated significantly lower muscle activities at knee and waist heights, suggesting these as the best working positions (47 cm to 107 cm) for minimizing the risk of WMSDs. Conversely, working at foot and shoulder heights was identified as a significant risk factor for WMSDs. Additionally, the similar trends observed between MSK simulations and sEMG data suggest that MSK modeling can effectively substitute for sEMG in future studies. These findings provide valuable insights into ergonomic work positioning to reduce WMSD risks among wall construction workers. Full article
(This article belongs to the Section Tissue and Vascular Biomechanics)
Show Figures

Figure 1

18 pages, 2976 KiB  
Article
Biomechanical Modeling and Simulation of the Knee Joint: Integration of AnyBody and Abaqus
by Catarina Rocha, João Lobo, Marco Parente and Dulce Oliveira
Biomechanics 2025, 5(3), 57; https://doi.org/10.3390/biomechanics5030057 (registering DOI) - 2 Aug 2025
Abstract
Background: The knee joint performs a vital function in human movement, supporting significant loads and ensuring stability during daily activities. Methods: The objective of this study was to develop and validate a subject-specific framework to model knee flexion–extension by integrating 3D gait data [...] Read more.
Background: The knee joint performs a vital function in human movement, supporting significant loads and ensuring stability during daily activities. Methods: The objective of this study was to develop and validate a subject-specific framework to model knee flexion–extension by integrating 3D gait data with individualized musculoskeletal (MS) and finite element (FE) models. In this proof of concept, gait data were collected from a 52-year-old woman using Xsens inertial sensors. The MS model was based on the same subject to define realistic loading, while the 3D knee FE model, built from another individual’s MRI, included all major anatomical structures, as subject-specific morphing was not possible due to unavailable scans. Results: The FE simulation showed principal stresses from –28.67 to +44.95 MPa, with compressive stresses between 2 and 8 MPa predominating in the tibial plateaus, consistent with normal gait. In the ACL, peak stress of 1.45 MPa occurred near the femoral insertion, decreasing non-uniformly with a compressive dip around –3.0 MPa. Displacement reached 0.99 mm in the distal tibia and decreased proximally. ACL displacement ranged from 0.45 to 0.80 mm, following a non-linear pattern likely due to ligament geometry and local constraints. Conclusions: These results support the model’s ability to replicate realistic, patient-specific joint mechanics. Full article
(This article belongs to the Section Gait and Posture Biomechanics)
Show Figures

Figure 1

14 pages, 572 KiB  
Review
Advancements in Total Knee Arthroplasty over the Last Two Decades
by Jakub Zimnoch, Piotr Syrówka and Beata Tarnacka
J. Clin. Med. 2025, 14(15), 5375; https://doi.org/10.3390/jcm14155375 - 30 Jul 2025
Viewed by 339
Abstract
Total knee arthroplasty is an extensive orthopedic surgery for patients with severe cases of osteoarthritis. This surgery restores the range of motion in the knee joint and allows for pain-free movement. Advancements in medical techniques used in the surgical zone and implant technology, [...] Read more.
Total knee arthroplasty is an extensive orthopedic surgery for patients with severe cases of osteoarthritis. This surgery restores the range of motion in the knee joint and allows for pain-free movement. Advancements in medical techniques used in the surgical zone and implant technology, as well as the management of operations and administration for around two decades prior, have hugely improved surgical outcomes for patients. In this study, advancements in TKA were examined through exploring aspects such as robotic surgery, new implants and materials, minimally invasive surgery, and post-surgery rehabilitation. This paper entails a review of the peer-reviewed literature published between 2005 and 2025 in the PubMed and Google Scholar databases. For predictors, we incorporated clinical relevance together with methodological soundness and relation to review questions to select relevant research articles. We used the PRISMA flowchart to illustrate the article selection system in its entirety. Since robotic surgical and navigation systems have been implemented, surgical accuracy has improved, there is an increased possibility of ensuring alignment, and the use of cementless and 3D-printed implants has increased, offering durable long-term fixation features. The trend in the current literature is that minimally invasive knee surgery (MIS) techniques reduce permanent pain after surgery and length of hospital stays for patients, though the long-term impact still needs to be established. There is various evidence outlining that the enhanced recovery after surgery (ERAS) protocols show positive results in terms of functional recovery and patient satisfaction. The integration of these new advancements enhances TKA surgeries and translates them into ‘need of patient’ procedures, ensuring improved results and increases in patient satisfaction. The aim of this study was to perform a comprehensive analysis of the existing literature regarding TKA advancement studies to identify current gaps and problems. Full article
(This article belongs to the Special Issue Joint Arthroplasties: From Surgery to Recovery)
Show Figures

Figure 1

16 pages, 2084 KiB  
Article
Accelerometer Measurements: A Learning Tool to Help Older Adults Understand the Importance of Soft-Landing Techniques in a Community Walking Class
by Tatsuo Doi, Ryosuke Haruna, Naoyo Kamioka, Shuzo Bonkohara and Nobuko Hongu
Sensors 2025, 25(15), 4546; https://doi.org/10.3390/s25154546 - 22 Jul 2025
Viewed by 208
Abstract
When people overextend their step length, it leads to an increase in vertical movement and braking force. The overextension elevates landing impacts, which may increase pain in the knees or lower back. The objective of this study was to examine the effects of [...] Read more.
When people overextend their step length, it leads to an increase in vertical movement and braking force. The overextension elevates landing impacts, which may increase pain in the knees or lower back. The objective of this study was to examine the effects of soft-landing walking techniques in a 90 min, instructor-led group class for older adults. To evaluate a landing impact, an accelerometer measurement system (Descente LTD., Tokyo, Japan) was used to measure a participant 10 meter (m) of walking. Assessment outcomes included the average number of steps, step length, upward acceleration which reflects the landing impact, and survey questions. A total of 223 older adults (31 men, 192 women, mean age 74.4 ± 5.7 years) completed the walking lesson. Following the lesson, participants decreased their step lengths and reduced upward acceleration, along with an increased step count. The number of steps increased, and a positive correlation (r = 0.73, p < 0.01) was observed between the rate of change in step length and upward acceleration. Over 95% of participants gave high marks for practicality and understanding the accelerometer measurements. The information derived from this study will provide valuable insight into the effectiveness of soft-landing techniques as a promotion of a healthy walking program for older adults. Full article
(This article belongs to the Special Issue Advanced Sensors for Health Monitoring in Older Adults)
Show Figures

Figure 1

12 pages, 2851 KiB  
Article
Comparative Analysis of Mechanical Variables in Different Exercises Performed with a Rotational Inertial Device in Professional Soccer Players: A Pilot Study
by Álvaro Murillo-Ortiz, Luis Manuel Martínez-Aranda, Moisés Falces-Prieto, Samuel López-Mariscal, Francisco Javier Iglesias-García and Javier Raya-González
J. Funct. Morphol. Kinesiol. 2025, 10(3), 279; https://doi.org/10.3390/jfmk10030279 - 18 Jul 2025
Viewed by 313
Abstract
Background: Soccer performance is largely dependent on high-intensity, unilateral actions such as sprints, jumps, and changes of direction. These demands can lead to strength and power differences between limbs, highlighting the importance of individualised assessment in professional players. Rotational inertial devices offer a [...] Read more.
Background: Soccer performance is largely dependent on high-intensity, unilateral actions such as sprints, jumps, and changes of direction. These demands can lead to strength and power differences between limbs, highlighting the importance of individualised assessment in professional players. Rotational inertial devices offer a valuable method to evaluate and train these mechanical variables separately for each leg. The aim of this study was twofold: (a) to characterise the mechanical variables derived from several lower-body strength exercises performed on rotational inertial devices, all targeting the same muscle group; and (b) to compare the mechanical variables between the dominant and non-dominant leg for each exercise. Methods: Twenty-six male professional soccer players (age = 26.3 ± 5.1 years; height = 182.3 ± 0.6 cm; weight = 75.9 ± 5.9 kg; body mass index = 22.8 ± 1.1 kg/m2; fat mass percentage = 9.1 ± 0.6%; fat-free mass = 68.8 ± 5.3 kg), all belonging to the same professional Belgian team, voluntarily participated in this study. The players completed a single assessment session consisting of six unilateral exercises (i.e., quadriceps hip, hamstring knee, adductor, quadriceps knee, hamstring hip, and abductor). For each exercise, they performed two sets of eight repetitions with each leg (i.e., dominant and non-dominant) in a randomised order. Results: The quadriceps hip exercise resulted in higher mechanical values compared to the quadriceps knee exercise in both limbs (p < 0.004). Similarly, the hamstring hip exercise produced greater values across all variables and limbs (p < 0.004), except for peak force, where the hamstring knee exercise exhibited higher values (p < 0.004). The adductor exercise showed higher peak force values for the dominant limb (p < 0.004). The between-limb comparison revealed differences only in the abductor exercise (p < 0.004). Conclusions: These findings suggest the necessity of prioritising movement selection based on targeted outcomes, although it should be considered that the differences between limb differences are very limited. Full article
(This article belongs to the Special Issue Sports-Specific Conditioning: Techniques and Applications)
Show Figures

Figure 1

17 pages, 2840 KiB  
Article
A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint
by Tian Liu, Liangzheng Sun, Chaoyue Sun, Zhijie Chen, Jian Li and Peng Su
Electronics 2025, 14(14), 2867; https://doi.org/10.3390/electronics14142867 - 18 Jul 2025
Viewed by 229
Abstract
(1) Background: A severe decline in knee joint function significantly affects the mobility of the elderly, making it a key concern in the field of geriatric health. To alleviate the pressure on the knee joints of the elderly during daily movements such as [...] Read more.
(1) Background: A severe decline in knee joint function significantly affects the mobility of the elderly, making it a key concern in the field of geriatric health. To alleviate the pressure on the knee joints of the elderly during daily movements such as sitting and standing, effective biomechanical solutions are required. (2) Methods: In this study, a biomechanical framework was established based on mechanical analysis to derive the transfer relationship between the ground reaction force and the knee joint moment. Experiments were designed to collect knee joint data on the elderly during the sit-to-stand process. Meanwhile, magnetic resonance imaging (MRI) images were processed through a medical imaging control system to construct a detailed digital 3D knee joint model. A finite element analysis was used to verify the model to ensure the accuracy of its structure and mechanical properties. An improved radial basis function was used to fit the pressure during the entire sit-to-stand conversion process to reduce the computational workload, with an error of less than 5%. In addition, a small-target human key point recognition network was developed to analyze the image sequences captured by the camera. The knee joint angle and the knee joint pressure distribution during the sit-to-stand conversion process were mapped to a three-dimensional interactive platform to form a digital twin system. (3) Results: The system can effectively capture the biomechanical behavior of the knee joint during movement and shows high accuracy in joint angle tracking and structure simulation. (4) Conclusions: This study provides an accurate and comprehensive method for analyzing the biomechanical characteristics of the knee joint during the movement of the elderly, laying a solid foundation for clinical rehabilitation research and the design of assistive devices in the field of rehabilitation medicine. Full article
(This article belongs to the Section Artificial Intelligence)
Show Figures

Figure 1

10 pages, 478 KiB  
Article
Knee Loading Asymmetries During Descent and Ascent Phases of Squatting After ACL Reconstruction
by Manuel Angel Romero Padron, Alyx Jorgensen, David M. Werner, Matthew Alan Tao and Elizabeth Wellsandt
Appl. Sci. 2025, 15(14), 7780; https://doi.org/10.3390/app15147780 - 11 Jul 2025
Viewed by 268
Abstract
Asymmetries are common during squats following anterior cruciate ligament reconstruction (ACLR). This study examined interlimb loading differences between squat phases at 6 months post-ACLR. Thirty-five participants performed bodyweight squats at self-selected speed and were analyzed using 3D motion capture. Vertical ground reaction force [...] Read more.
Asymmetries are common during squats following anterior cruciate ligament reconstruction (ACLR). This study examined interlimb loading differences between squat phases at 6 months post-ACLR. Thirty-five participants performed bodyweight squats at self-selected speed and were analyzed using 3D motion capture. Vertical ground reaction force impulse (vGRFi), external knee flexion moment impulse (KFMi) and hip-to-knee flexion moment impulse ratio (HKRi) were calculated, along with interlimb ratios (ILR). Squat phase durations were also recorded. Paired t-tests and ANCOVA (controlling for time) were used to compare biomechanical variables across squat phases. Greater asymmetry was observed during ascent for vGRFi ILR (p = 0.045), KFMi ILR (p < 0.001) and HKRi ILR (p = 0.006). The ascent phase was faster than descent (p = 0.036). After adjusting for time, phase-related differences in ILRs were no longer significant. These findings suggest that greater limb and knee-specific loading asymmetries occur during the ascent phase of squats but may be influenced by movement speed. Importantly, significant knee-specific loading asymmetries persisted regardless of squat phase. At 6 months post-ACLR, addressing neuromuscular control and movement speed during rehabilitation may help reduce biomechanical imbalances during closed kinetic chain exercises. Full article
(This article belongs to the Special Issue Applied Biomechanics and Sports Sciences)
Show Figures

Figure 1

18 pages, 3160 KiB  
Article
Acute Effects of Different Types of Compression Legwear on Biomechanics of Countermovement Jump: A Statistical Parametric Mapping Analysis
by Rui-Feng Huang, Kit-Lun Yick, Qiu-Qiong Shi, Lin Liu and Chu-Hao Li
J. Funct. Morphol. Kinesiol. 2025, 10(3), 257; https://doi.org/10.3390/jfmk10030257 - 7 Jul 2025
Viewed by 272
Abstract
Background: Compression garments (CG) may influence countermovement jump (CMJ) performance by altering hip and knee biomechanics, but existing evidence remains controversial. This study aimed to compare the effects of compression tights (CTs), compression shorts (CSs), and control shorts (CCs) on CMJ performance [...] Read more.
Background: Compression garments (CG) may influence countermovement jump (CMJ) performance by altering hip and knee biomechanics, but existing evidence remains controversial. This study aimed to compare the effects of compression tights (CTs), compression shorts (CSs), and control shorts (CCs) on CMJ performance and lower-limb biomechanics. Methods: Nine physically active men from a university were recruited to perform CMJ while wearing CTs, CSs, and CCs in a randomized sequence for a within-subjects repeated-measures design. A Vicon 3D motion capture system and an AMTI 3D force plate were used to collect biomechanical data. Visual3D software was used to calculate the joint angle, moment, and force of the lower limbs. Results: Statistical parametric mapping analysis with repeated measures analysis of variance (ANOVA) revealed that during the propulsion phase of the CMJ, wearing CSs significantly reduced the hip flexion angle compared to wearing CCs (25–36%); meanwhile, wearing CTs significantly reduced the knee extension and flexion moment (34–35%) and decreased the hip extension moment during the propulsion phase (36–37%). In addition, CTs significantly reduced the hip abduction angle during the flight phase (37–39%), and CSs significantly reduced the hip anterior force during the landing phase (59–60%). Conclusions: Compression legwear significantly affected the hip and knee biomechanics in propulsion, but these differences were not sufficient to improve the CMJ height. Due to the improvement in hip biomechanics in the flight and landing phases, there may be potential benefits for movement transitions and landing performance in CMJ. Full article
(This article belongs to the Section Kinesiology and Biomechanics)
Show Figures

Figure 1

15 pages, 2628 KiB  
Article
High Anti-Swelling Zwitterion-Based Hydrogel with Merit Stretchability and Conductivity for Motion Detection and Information Transmission
by Qingyun Zheng, Jingyuan Liu, Rongrong Chen, Qi Liu, Jing Yu, Jiahui Zhu and Peili Liu
Nanomaterials 2025, 15(13), 1027; https://doi.org/10.3390/nano15131027 - 2 Jul 2025
Viewed by 426
Abstract
Hydrogel sensors show unique advantages in underwater detection, ocean monitoring, and human–computer interaction because of their excellent flexibility, biocompatibility, high sensitivity, and environmental adaptability. However, due to the water environment, hydrogels will dissolve to a certain extent, resulting in insufficient mechanical strength, poor [...] Read more.
Hydrogel sensors show unique advantages in underwater detection, ocean monitoring, and human–computer interaction because of their excellent flexibility, biocompatibility, high sensitivity, and environmental adaptability. However, due to the water environment, hydrogels will dissolve to a certain extent, resulting in insufficient mechanical strength, poor long-term stability, and signal interference. In this paper, a double-network structure was constructed by polyvinyl alcohol (PVA) and poly([2-(methacryloyloxy) ethyl]7 dimethyl-(3-sulfopropyl) ammonium hydroxide) (PSBMA). The resultant PVA/PSBMA-PA hydrogel demonstrated notable swelling resistance, a property attributable to the incorporation of non-covalent interactions (electrostatic interactions and hydrogen bonding) through the addition of phytic acid (PA). The hydrogel exhibited high stretchability (maximum tensile strength up to 304 kPa), high conductivity (5.8 mS/cm), and anti-swelling (only 1.8% swelling occurred after 14 days of immersion in artificial seawater). Assembled as a sensor, it exhibited high strain sensitivity (0.77), a low detection limit (1%), and stable electrical properties after multiple tensile cycles. The utilization of PVA/PSBMA-PA hydrogel as a wearable sensor shows promise for detecting human joint movements, including those of the fingers, wrists, elbows, and knees. Due to the excellent resistance to swelling, the PVA/PSBMA-PA-based sensors are also suitable for underwater applications, enabling the detection of underwater mannequin motion. This study proposes an uncomplicated and pragmatic methodology for producing hydrogel sensors suitable for use within subaquatic environments, thereby concomitantly broadening the scope of applications for wearable electronic devices. Full article
(This article belongs to the Special Issue Nanomaterials in Flexible Sensing and Devices)
Show Figures

Figure 1

29 pages, 2460 KiB  
Review
A Survey on Design and Control Methodologies of High- Torque-Density Joints for Compliant Lower-Limb Exoskeleton
by Jingbo Xu, Silu Chen, Shupei Li, Yong Liu, Hongyu Wan, Zhuang Xu and Chi Zhang
Sensors 2025, 25(13), 4016; https://doi.org/10.3390/s25134016 - 27 Jun 2025
Viewed by 516
Abstract
The lower-limb assistance exoskeleton is increasingly being utilized in various fields due to its excellent performance in human body assistance. As a crucial component of robots, the joint is expected to be designed with a high-output torque to support hip and knee movement, [...] Read more.
The lower-limb assistance exoskeleton is increasingly being utilized in various fields due to its excellent performance in human body assistance. As a crucial component of robots, the joint is expected to be designed with a high-output torque to support hip and knee movement, and lightweight to enhance user experience. Contrasted with the elastic actuation with harmonic drive and other flexible transmission, the non-elastic quasi-direct actuation is more promising to be applied in exoskeleton due to its advanced dynamic performance and lightweight feature. Moreover, robot joints are commonly driven electrically, especially by a permanent magnet synchronous motor which is rapidly developed because of its compact structure and powerful output. Based on different topological structures, numerous research focus on torque density, ripple torque suppression, efficiency improvement, and thermal management to improve motor performance. Furthermore, the elaborated joint with powerful motors should be controlled compliantly to improve flexibility and interaction, and therefore, popular complaint control algorithms like impedance and admittance controls are discussed in this paper. Through the review and analysis of the integrated design from mechanism structure to control algorithm, it is expected to indicate developmental prospects of lower-limb assistance exoskeleton joints with optimized performance. Full article
Show Figures

Figure 1

14 pages, 1184 KiB  
Article
Normative Knee Range of Motion for Children
by Muhammad Uba Abdulazeez, Maryam Alhefeiti, Shahad Alhammadi, Hajar Alnuaimi, Aminu Sabo Abdullahi, Lobna Shaikhoun, Kamiar Aminian, Georgios Antoniou Stylianides and Kassim Abdulrahman Abdullah
Life 2025, 15(7), 1000; https://doi.org/10.3390/life15071000 - 24 Jun 2025
Viewed by 546
Abstract
Children may suffer knee injuries due to motor vehicle crashes, sports, and falls. Additionally, children can suffer from rheumatic, neurological, musculoskeletal, and neuromuscular disorders which restrict joint movement. These types of injuries and disorders often result in knee joint impairment, thereby affecting joint [...] Read more.
Children may suffer knee injuries due to motor vehicle crashes, sports, and falls. Additionally, children can suffer from rheumatic, neurological, musculoskeletal, and neuromuscular disorders which restrict joint movement. These types of injuries and disorders often result in knee joint impairment, thereby affecting joint mobility. Understanding the range of motion (ROM) of the pediatric knee is vital in diagnosing, examining, and treating these injuries and disorders. This study was undertaken to establish normative values for passive (PROM) and active (AROM) range of motion of the pediatric knee and to examine the effects of anthropometric and demographic factors on knee joint ROM. Normative reference values for both passive and active knee ROM were established for 295 children in the United Arab Emirates (Arab and South Asian ethnicity). The subjects’ PROM averaged 131.2° (117.2°, 140.2°) for boys and 132.8° (120.9°, 140.3°) for girls. Similarly, the observed PROM for children was 132.2° (118.6°, 141.2°), versus 130.8° (119.9°, 139.3°) for adolescents. Conversely, the subjects’ AROM averaged 129.3° (118.8°, 137.9°) for boys and 130.5° (120.9°, 137.4°) for girls. The observed AROM averaged 130.2° (119.5°, 137.8°) for children and 128.6° (121.5°, 137.4°) for adolescents. Significant differences in knee ROM based on ethnicity were identified. Additionally, significant correlations were observed between anthropometric factors and knee joint ROM. The gender and age-based normative values established in this study can be used in medical and vehicle safety analyses of knee injuries sustained by children as well as in the evaluation of knee joint impairments due to rheumatic, neurological, musculoskeletal, and neuromuscular disorders, thereby improving the outcomes of knee injuries and the treatment of joint impairments in children. Full article
(This article belongs to the Special Issue Feature Paper in Physiology and Pathology: 2nd Edition)
Show Figures

Figure 1

17 pages, 528 KiB  
Systematic Review
Advances in Badminton Footwear Design: A Systematic Review of Biomechanical and Performance Implications
by Meixi Pan, Zihao Chen, Dongxu Huang, Zixin Wu, Fengjiao Xue, Jorge Diaz-Cidoncha Garcia, Qing Yi and Siqin Shen
Appl. Sci. 2025, 15(13), 7066; https://doi.org/10.3390/app15137066 - 23 Jun 2025
Viewed by 488
Abstract
This systematic review, registered in PROSPERO (CRD42025101243), aimed to evaluate how specific badminton shoe design features influence lower-limb biomechanics, injury risk, and sport-specific performance. A comprehensive search in six databases yielded 445 studies, from which 10 met inclusion criteria after duplicate removal and [...] Read more.
This systematic review, registered in PROSPERO (CRD42025101243), aimed to evaluate how specific badminton shoe design features influence lower-limb biomechanics, injury risk, and sport-specific performance. A comprehensive search in six databases yielded 445 studies, from which 10 met inclusion criteria after duplicate removal and eligibility screening. The reviewed studies focused on modifications involving forefoot bending stiffness, torsional stiffness, lateral-wedge hardness, insole and midsole hardness, sole structure, and heel curvature. The most consistent biomechanical benefits were associated with moderate levels of forefoot and torsional stiffness (e.g., 60D) and rounded heel designs. Increased forefoot bending stiffness was associated with reduced foot torsion and knee loading during forward lunges. Torsional stiffness around 60D provided favorable ankle support and reduced knee abduction, suggesting potential protection against ligament strain. Rounded heels reduced vertical impact forces and promoted smoother knee–ankle coordination, especially in experienced athletes. Lateral-wedge designs improved movement efficiency by reducing contact time and enhancing joint stiffness. Harder midsoles, however, resulted in increased impact forces upon landing. Excessive stiffness in any component may restrict joint mobility and responsiveness. Studies included 127 male-dominated (aged 18–28) competitive athletes, assessing kinematics, impact forces, and coordination during sport-specific tasks. The reviewed studies predominantly involved male participants, with little attention to sex-specific biomechanical differences such as joint alignment and foot structure. Differences in testing methods and movement tasks further limited direct comparisons. Future research should explore real-game biomechanics, include diverse athlete populations, and investigate long-term adaptations. These efforts will contribute to the development of performance-enhancing, injury-reducing badminton shoes tailored to the unique demands of the sport. Full article
(This article belongs to the Section Biomedical Engineering)
Show Figures

Figure 1

13 pages, 1678 KiB  
Article
Running and Jumping After Muscle Fatigue in Subjects with a History of Knee Injury: What Are the Acute Effects of Wearing a Knee Brace on Biomechanics?
by Tobias Heß, Thomas L. Milani, Jan Stoll and Christian Mitschke
Bioengineering 2025, 12(6), 661; https://doi.org/10.3390/bioengineering12060661 - 16 Jun 2025
Viewed by 1170
Abstract
The knee is one of the most frequently injured joints, involving various structures. To prevent reinjury after rehabilitation, braces are commonly used. However, most studies on knee supports focus on subjects with anterior cruciate ligament (ACL) injuries and do not account for muscle [...] Read more.
The knee is one of the most frequently injured joints, involving various structures. To prevent reinjury after rehabilitation, braces are commonly used. However, most studies on knee supports focus on subjects with anterior cruciate ligament (ACL) injuries and do not account for muscle fatigue, which typically occurs during prolonged intense training and can significantly increase the risk of injury. Hence, this study investigates the acute effects of wearing a knee brace on biomechanics in subjects with a history of various unilateral knee injuries or pain under muscle fatigue. In total, 50 subjects completed an intense fatigue protocol and then performed counter-movement jumps and running tests on a force plate while tracking kinematics with a marker-based 3D motion analysis system. Additionally, subjects filled out a visual analog scale (VAS) to assess knee pain and stability. Tests were conducted on the injured leg with and without a knee brace (Sports Knee Support, Bauerfeind AG, Zeulenroda-Triebes, Germany) and on the healthy leg. Results indicated that wearing the knee brace stabilized knee movement in the frontal plane, with a significant reduction in maximal medio-lateral knee acceleration and knee abduction moment during running and jumping. The brace also normalized loading on the injured leg. We observed higher maximal knee flexion moments, which were associated with increased vertical ground reaction forces, segment velocities, and knee flexion angles. Subjects reported less pain and greater stability while wearing the knee brace. Therefore, we confirm that wearing a knee brace on the injured leg improves joint biomechanics by enhancing stability and kinematics and reducing pain during running and jumping, even with muscle fatigue. Consequently, wearing a knee brace after a knee joint injury may reduce the risk of reinjury. Full article
(This article belongs to the Special Issue Biomechanics of Orthopaedic Rehabilitation)
Show Figures

Figure 1

15 pages, 589 KiB  
Article
A Comparative Study of the Effects of Augmented Reality Application on Movement Accuracy and Subjective Satisfaction in Rehabilitation Training for Individuals with Lower Limb Amputations
by Yunhee Chang, Jungsun Kang, Hyeonseok Cho and Sehoon Park
Appl. Sci. 2025, 15(12), 6703; https://doi.org/10.3390/app15126703 - 14 Jun 2025
Viewed by 457
Abstract
This study investigated the efficacy of Augmented Reality (AR) in the rehabilitation of lower limb amputees by comparing movement accuracy and subjective satisfaction with and without AR. Ten individuals with unilateral lower limb amputations participated. Joint range of motion during exercises was measured [...] Read more.
This study investigated the efficacy of Augmented Reality (AR) in the rehabilitation of lower limb amputees by comparing movement accuracy and subjective satisfaction with and without AR. Ten individuals with unilateral lower limb amputations participated. Joint range of motion during exercises was measured using a 3D motion capture system. Subjective satisfaction was assessed via a 5-point Likert scale. Movement accuracy was evaluated by analyzing changes and variability (standard deviation) in joint angles across eight selected movements. Results showed that AR feedback significantly increased average joint angles in specific movements: standing arm raise to the side, standing trunk lateral flexion, and standing knee flexion to maximum height. Furthermore, AR feedback led to a significant reduction in the standard deviation of joint angles for most exercises, indicating improved movement consistency. Subjective satisfaction scores for interest, motivation, exercise effectiveness, movement accuracy, and overall satisfaction were significantly higher with AR. Full article
Show Figures

Figure 1

20 pages, 2853 KiB  
Article
Three-Dimensional Pedalling Kinematics Analysis Through the Development of a New Marker Protocol Specific to Cycling
by Ezequiel Martín-Sosa, Elena Soler-Vizán, Juana Mayo and Joaquín Ojeda
Appl. Sci. 2025, 15(12), 6382; https://doi.org/10.3390/app15126382 - 6 Jun 2025
Viewed by 450
Abstract
This study aims to develop and evaluate a cycling-specific marker protocol that minimises the number of markers while accounting for the unique biomechanics of cycling. Although movements in the frontal and transverse planes during cycling are limited, they are clinically relevant due to [...] Read more.
This study aims to develop and evaluate a cycling-specific marker protocol that minimises the number of markers while accounting for the unique biomechanics of cycling. Although movements in the frontal and transverse planes during cycling are limited, they are clinically relevant due to their association with overuse injuries. Existing gait-based marker protocols often fail to consider cycling-specific factors such as posture, range of motion, marker occlusion, and muscle-induced artifacts. The proposed protocol (PP) uses 15 physical and 8 virtual markers. In the absence of a gold standard for 3D pedalling kinematics, the PP was evaluated by comparing it with established gait analysis protocols. The protocol demonstrated high correlation in gait (CCC > 0.98 for hip and knee in the sagittal plane), low intra-subject variability (CV < 15% for hip, knee, and ankle), and high repeatability. During pedalling, position, velocity, and acceleration were measured in all three spatial directions. Notably, angular velocity and linear acceleration showed significant components outside the sagittal plane, particularly for angular velocity. These findings highlight the importance of considering 3D motion when estimating forces, joint moments, and joint-specific powers in cycling biomechanics. Full article
Show Figures

Figure 1

Back to TopTop