Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = human magneto sensitivity

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2917 KiB  
Article
Tunable Magneto-Plasmonic Nanosensor for Sensitive Detection of Foodborne Pathogens
by Tuhina Banerjee, Nilamben Panchal, Carissa Sutton, Rebekah Elliott, Truptiben Patel, Kajal Kajal, Eniola Arogunyo, Neelima Koti and Santimukul Santra
Biosensors 2023, 13(1), 109; https://doi.org/10.3390/bios13010109 - 7 Jan 2023
Cited by 6 | Viewed by 3627
Abstract
Frequent outbreaks of food-borne pathogens, particularly E. coli O157:H7, continue to impact human health and the agricultural economy tremendously. The required cell count for this pathogenic strain of E. coli O157:H7 is relatively low and hence it is vital to detect at low [...] Read more.
Frequent outbreaks of food-borne pathogens, particularly E. coli O157:H7, continue to impact human health and the agricultural economy tremendously. The required cell count for this pathogenic strain of E. coli O157:H7 is relatively low and hence it is vital to detect at low colony forming unit (CFU) counts. Available detection methods, though sensitive, fall short in terms of timeliness and often require extensive sample processing. To overcome these limitations, we propose a novel magneto-plasmonic nanosensor (MPnS) by integrating surface plasmon resonance (SPR) properties with spin–spin magnetic relaxation (T2 MR) technology. We engineered MPnS by encapsulating several gold nanoparticles (GNPs) within the polymer-coating of iron oxide nanoparticles (IONPs). First, the polyacrylic acid (PAA)-coated IONPs were synthesized using a solvent precipitation method, then gold chloride solution was used to synthesize GNPs and encapsulate them within the PAA-coatings of IONPs in one step. A magnetic separation technique was used to purify the MPnS and the presence of GNPs within IONPs was characterized using transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy (EDS), and other spectroscopic methods. The synthesized MPnS exhibits MR relaxation properties while possessing amplified optical properties than conventional GNPs. This allows for rapid and ultrasensitive detection of E. coli O157:H7 by SPR, T2 MR, and colorimetric readout. Experiments conducted in simple buffer and in milk as a complex media demonstrated that our MPnS-based assay could detect as low as 10 CFUs of this pathogenic strain of E. coli O157:H7 in minutes with no cross-reactivity. Overall, the formulated MPnS is robust and holds great potential for the ultrasensitive detection of E. coli O157:H7 in a simple and timely fashion. Moreover, this platform is highly customizable and can be used for the detection of other foodborne pathogens. Full article
Show Figures

Figure 1

21 pages, 62092 KiB  
Review
Magneto-Mechano-Electric (MME) Composite Devices for Energy Harvesting and Magnetic Field Sensing Applications
by Srinivas Pattipaka, Jaewon Jeong, Hyunsu Choi, Jungho Ryu and Geon-Tae Hwang
Sensors 2022, 22(15), 5723; https://doi.org/10.3390/s22155723 - 30 Jul 2022
Cited by 22 | Viewed by 5903
Abstract
Magneto-mechano-electric (MME) composite devices have been used in energy harvesting and magnetic field sensing applications due to their advantages including their high-performance, simple structure, and stable properties. Recently developed MME devices can convert stray magnetic fields into electric signals, thus generating an output [...] Read more.
Magneto-mechano-electric (MME) composite devices have been used in energy harvesting and magnetic field sensing applications due to their advantages including their high-performance, simple structure, and stable properties. Recently developed MME devices can convert stray magnetic fields into electric signals, thus generating an output power of over 50 mW and detecting ultra-tiny magnetic fields below pT. These inherent outstanding properties of MME devices can enable the development of not only self-powered energy harvesters for internet of thing (IoT) systems but also ultra-sensitive magnetic field sensors for diagnosis of human bio-magnetism or others. This manuscript provides a brief overview of recently reported high-performance MME devices for energy harvesting and magnetic sensing applications. Full article
(This article belongs to the Special Issue Magnetoelectric Thin-Film Based Devices)
Show Figures

Figure 1

18 pages, 6444 KiB  
Article
A Uniform Magnetic Field Generator Combined with a Thin-Film Magneto-Impedance Sensor Capable of Human Body Scans
by Tomoo Nakai
Sensors 2022, 22(9), 3120; https://doi.org/10.3390/s22093120 - 19 Apr 2022
Cited by 11 | Viewed by 3073
Abstract
A detection system for magnetic inclusions of large bulk, such as that of a whole human body, is proposed in this paper. The system consists of both a uniform magnetic field generating apparatus capable of the insertion of a whole human body and [...] Read more.
A detection system for magnetic inclusions of large bulk, such as that of a whole human body, is proposed in this paper. The system consists of both a uniform magnetic field generating apparatus capable of the insertion of a whole human body and also of a high-sensitivity magnetic sensor array installed in the strong magnetic field. The system can detect the magnetic inclusion simultaneously through its magnetization, which is advantageous for detecting low-remanence magnetic materials, such as a cluster of nanoparticles. The thin-film magneto-impedance sensor was reported to be capable of tolerating strong magnetic fields of more than 3000 Gauss (0.3 T) in the substrate’s normal direction and can retain its sensitivity even in strong fields. Through a combination of both uniformity of strength and the placement of its directionally aligned, static magnetic field in a particular measurement area and its array of single-dimensional thin-film magneto-impedance sensors, it was reported that it can estimate a magnetic sample’s 3D position by using a simple equation. The aim of the system developed in this study is to nondestructively detect a cluster of magnetic nanoparticles in a human body and also to detect the position and the concentration of the clustered magnetic particles. In this paper, a prototype system consisting of a magnetic field generator with an area of W500 mm × L400 mm × H210 mm and a uniform magnetic field of 370 Gauss (37 mT) is reported. It also reported that the thin-film magneto-impedance sensor installed in the system verified the detection of 2 mm × 1 mm small ellipsoidal magnetic chips at a distance of 27 mm from the sensor element. Full article
(This article belongs to the Special Issue Sensors and Biosensors Related to Magnetic Nanoparticles)
Show Figures

Figure 1

10 pages, 1905 KiB  
Article
7-Tesla Functional Cardiovascular MR Using Vectorcardiographic Triggering—Overcoming the Magnetohydrodynamic Effect
by Christian Hamilton-Craig, Daniel Stäeb, Aiman Al Najjar, Kieran O’Brien, William Crawford, Sabine Fletcher, Markus Barth and Graham Galloway
Tomography 2021, 7(3), 323-332; https://doi.org/10.3390/tomography7030029 - 4 Aug 2021
Cited by 4 | Viewed by 2784
Abstract
Objective: Ultra-high-field B0 ≥ 7 tesla (7T) cardiovascular magnetic resonance (CMR) offers increased resolution. However, electrocardiogram (ECG) gating is impacted by the magneto-hydrodynamic effect distorting the ECG trace. We explored the technical feasibility of a 7T magnetic resonance scanner using an ECG trigger [...] Read more.
Objective: Ultra-high-field B0 ≥ 7 tesla (7T) cardiovascular magnetic resonance (CMR) offers increased resolution. However, electrocardiogram (ECG) gating is impacted by the magneto-hydrodynamic effect distorting the ECG trace. We explored the technical feasibility of a 7T magnetic resonance scanner using an ECG trigger learning algorithm to quantitatively assess cardiac volumes and vascular flow. Methods: 7T scans were performed on 10 healthy volunteers on a whole-body research MRI MR scanner (Siemens Healthineers, Erlangen, Germany) with 8 channel Tx/32 channels Rx cardiac coils (MRI Tools GmbH, Berlin, Germany). Vectorcardiogram ECG was performed using a learning phase outside of the magnetic field, with a trigger algorithm overcoming severe ECG signal distortions. Vectorcardiograms were quantitatively analyzed for false negative and false positive events. Cine CMR was performed after 3rd-order B0 shimming using a high-resolution breath-held ECG-retro-gated segmented spoiled gradient echo, and 2D phase contrast flow imaging. Artefacts were assessed using a semi-quantitative scale. Results: 7T CMR scans were acquired in all patients (100%) using the vectorcardiogram learning method. 3,142 R-waves were quantitatively analyzed, yielding sensitivity of 97.6% and specificity of 98.7%. Mean image quality score was 0.9, sufficient to quantitate both cardiac volumes, ejection fraction, and aortic and pulmonary blood flow. Mean left ventricular ejection fraction was 56.4%, right ventricular ejection fraction was 51.4%. Conclusion: Reliable cardiac ECG triggering is feasible in healthy volunteers at 7T utilizing a state-of-the-art three-lead trigger device despite signal distortion from the magnetohydrodynamic effect. This provides sufficient image quality for quantitative analysis. Other ultra-high-field imaging applications such as human brain functional MRI with physiologic noise correction may benefit from this method of ECG triggering. Full article
Show Figures

Figure 1

28 pages, 620 KiB  
Review
The Possible Effect of Space Weather Factors on Various Physiological Systems of the Human Organism
by Tatiana Alexandrovna Zenchenko and Tamara Konstantinovna Breus
Atmosphere 2021, 12(3), 346; https://doi.org/10.3390/atmos12030346 - 6 Mar 2021
Cited by 32 | Viewed by 13503
Abstract
A systematic review of heliobiological studies of the last 25 years devoted to the study of the potential influence of space weather factors on human health and well-being was carried out. We proposed three criteria (coordinates), according to which the work on solar–biospheric [...] Read more.
A systematic review of heliobiological studies of the last 25 years devoted to the study of the potential influence of space weather factors on human health and well-being was carried out. We proposed three criteria (coordinates), according to which the work on solar–biospheric relations was systematized: the time scale of data sampling (years, days, hours, minutes); the level of organization of the biological system under study (population, group, individual, body system); and the degree of system response (norm, adaptation, failure of adaptation (illness), disaster (death)). This systematic review demonstrates that three parameters mentioned above are closely related in the existing heliobiological studies: the larger the selected time scale, the higher the level of estimated biological system organization and the stronger the potential response degree is. The long-term studies are devoted to the possible influence of solar activity on population disasters, i.e., significant increases in morbidity and mortality. On a daily scale, a probable effect of geomagnetic storms and other space weather events on short-term local outbreaks of morbidity is shown as well as on cases of deterioration in people functional state. On an intraday scale, in the regular functioning mode, the heart and brain rhythms of healthy people turn to be synchronized with geomagnetic field variations in some frequency ranges, which apparently is the necessary organism’s existence element. The applicability of different space weather indices at different data sampling rates, the need to take into account the contribution of meteorological factors, and the prospects for an individual approach in heliobiology are discussed. The modern important results of experiments on modeling the action of magnetic storms in laboratory conditions and the substantiation of possible theoreical mechanisms are described. These results provide an experimental and theoretical basis for studies of possible connections of space weather and human health. Full article
(This article belongs to the Special Issue The Impacts of Space Weather on Human Health)
Show Figures

Figure 1

12 pages, 1973 KiB  
Article
A Self-Calibrating IoT Portable Electrochemical Immunosensor for Serum Human Epididymis Protein 4 as a Tumor Biomarker for Ovarian Cancer
by Valentina Bianchi, Monica Mattarozzi, Marco Giannetto, Andrea Boni, Ilaria De Munari and Maria Careri
Sensors 2020, 20(7), 2016; https://doi.org/10.3390/s20072016 - 3 Apr 2020
Cited by 24 | Viewed by 4323
Abstract
Nowadays, analytical techniques are moving towards the development of smart biosensing strategies for the point-of-care accurate screening of disease biomarkers, such as human epididymis protein 4 (HE4), a recently discovered serum marker for early ovarian cancer diagnosis. In this context, the present work [...] Read more.
Nowadays, analytical techniques are moving towards the development of smart biosensing strategies for the point-of-care accurate screening of disease biomarkers, such as human epididymis protein 4 (HE4), a recently discovered serum marker for early ovarian cancer diagnosis. In this context, the present work represents the first implementation of a competitive enzyme-labelled magneto-immunoassay exploiting a homemade IoT Wi-Fi cloud-based portable potentiostat for differential pulse voltammetry readout. The electrochemical device was specifically designed to be capable of autonomous calibration and data processing, switching between calibration, and measurement modes: in particular, firstly, a baseline estimation algorithm is applied for correct peak computation, then calibration function is built by interpolating data with a four-parameter logistic function. The calibration function parameters are stored on the cloud for inverse prediction to determine the concentration of unknown samples. Interpolation function calibration and concentration evaluation are performed directly on-board, thus reducing the power consumption. The analytical device was validated in human serum, demonstrating good sensing performance for analysis of HE4 with detection and quantitation limits in human serum of 3.5 and 29.2 pM, respectively, reaching the sensitivity that is required for diagnostic purposes, with high potential for applications as portable and smart diagnostic tool for point-of-care testing. Full article
(This article belongs to the Special Issue Novel Electrochemical Biosensors for Clinical Assays)
Show Figures

Graphical abstract

13 pages, 1928 KiB  
Article
Highly Sensitive and Rapid Characterization of the Development of Synchronized Blood Stage Malaria Parasites Via Magneto-Optical Hemozoin Quantification
by Mária Pukáncsik, Petra Molnár, Ágnes Orbán, Ádám Butykai, Lívia Marton, István Kézsmárki, Beáta G. Vértessy, Mohd Kamil, Amanah Abraham and Ahmed S. I. Aly
Biomolecules 2019, 9(10), 579; https://doi.org/10.3390/biom9100579 - 7 Oct 2019
Cited by 14 | Viewed by 3758
Abstract
The rotating-crystal magneto-optical diagnostic (RMOD) technique was developed as a sensitive and rapid platform for malaria diagnosis. Herein, we report a detailed in vivo assessment of the synchronized Plasmodium vinckei lentum strain blood-stage infections by the RMOD method and comparing the results to [...] Read more.
The rotating-crystal magneto-optical diagnostic (RMOD) technique was developed as a sensitive and rapid platform for malaria diagnosis. Herein, we report a detailed in vivo assessment of the synchronized Plasmodium vinckei lentum strain blood-stage infections by the RMOD method and comparing the results to the unsynchronized Plasmodium yoelii 17X-NL (non-lethal) infections. Furthermore, we assess the hemozoin production and clearance dynamics in chloroquine-treated compared to untreated self-resolving infections by RMOD. The findings of the study suggest that the RMOD signal is directly proportional to the hemozoin content and closely follows the actual parasitemia level. The lack of long-term accumulation of hemozoin in peripheral blood implies a dynamic equilibrium between the hemozoin production rate of the parasites and the immune system’s clearing mechanism. Using parasites with synchronous blood stage cycle, which resemble human malaria parasite infections with Plasmodium falciparum and Plasmodium vivax, we are demonstrating that the RMOD detects both hemozoin production and clearance rates with high sensitivity and temporal resolution. Thus, RMOD technique offers a quantitative tool to follow the maturation of the malaria parasites even on sub-cycle timescales. Full article
Show Figures

Graphical abstract

14 pages, 1798 KiB  
Article
Magnetic Beads-Based Sensor with Tailored Sensitivity for Rapid and Single-Step Amperometric Determination of miRNAs
by Eva Vargas, Rebeca M. Torrente-Rodríguez, Víctor Ruiz-Valdepeñas Montiel, Eloy Povedano, María Pedrero, Juan J. Montoya, Susana Campuzano and José M. Pingarrón
Int. J. Mol. Sci. 2017, 18(11), 2151; https://doi.org/10.3390/ijms18112151 - 9 Nov 2017
Cited by 31 | Viewed by 10307
Abstract
This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs). The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21) with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs), and labeling [...] Read more.
This work describes a sensitive amperometric magneto-biosensor for single-step and rapid determination of microRNAs (miRNAs). The developed strategy involves the use of direct hybridization of the target miRNA (miRNA-21) with a specific biotinylated DNA probe immobilized on streptavidin-modified magnetic beads (MBs), and labeling of the resulting heteroduplexes with a specific DNA–RNA antibody and the bacterial protein A (ProtA) conjugated with an horseradish peroxidase (HRP) homopolymer (Poly-HRP40) as an enzymatic label for signal amplification. Amperometric detection is performed upon magnetic capture of the modified MBs onto the working electrode surface of disposable screen-printed carbon electrodes (SPCEs) using the H2O2/hydroquinone (HQ) system. The magnitude of the cathodic signal obtained at −0.20 V (vs. the Ag pseudo-reference electrode) demonstrated linear dependence with the concentration of the synthetic target miRNA over the 1.0 to 100 pM range. The method provided a detection limit (LOD) of 10 attomoles (in a 25 μL sample) without any target miRNA amplification in just 30 min (once the DNA capture probe-MBs were prepared). This approach shows improved sensitivity compared with that of biosensors constructed with the same anti-DNA–RNA Ab as capture instead of a detector antibody and further labeling with a Strep-HRP conjugate instead of the Poly-HRP40 homopolymer. The developed strategy involves a single step working protocol, as well as the possibility to tailor the sensitivity by enlarging the length of the DNA/miRNA heteroduplexes using additional probes and/or performing the labelling with ProtA conjugated with homopolymers prepared with different numbers of HRP molecules. The practical usefulness was demonstrated by determination of the endogenous levels of the mature target miRNA in 250 ng raw total RNA (RNAt) extracted from human mammary epithelial normal (MCF-10A) and cancer (MCF-7) cells and tumor tissues. Full article
(This article belongs to the Collection Regulation by Non-coding RNAs)
Show Figures

Graphical abstract

15 pages, 20213 KiB  
Article
Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications
by Stefano Bertuletti, Andrea Cereatti, Daniele Comotti, Michele Caldara and Ugo Della Croce
Sensors 2017, 17(7), 1492; https://doi.org/10.3390/s17071492 - 24 Jun 2017
Cited by 27 | Viewed by 7399
Abstract
Magneto-inertial measurement units (MIMU) are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. [...] Read more.
Magneto-inertial measurement units (MIMU) are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF), allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i) target colors; (ii) sensor-target distances (up to 200 mm) and (iii) sensor-target angles of incidence (AoI) (up to 60 ). Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black). Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0 , the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error <1.5 mm. Errors increased up to 3.6 mm (static) and 11.9 mm (dynamic) for AoI equal to ± 30 , and up to 7.8 mm (static) and 25.6 mm (dynamic) for AoI equal to ± 60 . In addition, the wearable platform was used during a preliminary experiment for the estimation of the inter-foot distance on a single healthy subject while walking. In conclusion, the combination of magneto-inertial unit and IR-ToF technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption, compared to existing technologies. Full article
(This article belongs to the Special Issue Inertial Sensors for Positioning and Navigation)
Show Figures

Figure 1

Back to TopTop