Search Results (20)

Search Parameters:
Keywords = hemoglobin as pulse oximetry

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 4295 KB  
Article
Transforming Fundus Photography for Deep Learning-Based Anemia Screening
by Taeseen Kang and Kiyup Nam
J. Clin. Med. 2026, 15(14), 5702; https://doi.org/10.3390/jcm15145702 - 21 Jul 2026
Viewed by 312
Abstract
Background/Objectives: This study aimed to develop and evaluate a noninvasive anemia screening method using fundus photographs analyzed by deep learning models, by transforming circular fundus photographs into square images suitable for convolutional neural network analysis. Methods: A total of 39,036 fundus images and [...] Read more.
Background/Objectives: This study aimed to develop and evaluate a noninvasive anemia screening method using fundus photographs analyzed by deep learning models, by transforming circular fundus photographs into square images suitable for convolutional neural network analysis. Methods: A total of 39,036 fundus images and clinical data collected from 2011 to 2023 were used. Eligible patients had clearly visible macula and optic discs and corresponding hemoglobin measurements. Three image preprocessing methods were applied—untransformed, stretching, and remapping. Results: Among preprocessing methods, the stretching method yielded the most accurate predictions. Deep learning analysis was conducted using multi-tasked cascaded convolutional neural networks. The hemoglobin prediction model based on EfficientNet B5 with remapping preprocessing achieved good performance (R2 = 0.781, MAE = 1.23), while the anemia classification model demonstrated screening accuracy with AUC values exceeding 0.893. Conclusions: Deep learning analysis of fundus photographs demonstrates potential as a noninvasive screening method for anemia. This approach may be particularly beneficial for patients requiring regular hemoglobin monitoring. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

15 pages, 1246 KB  
Review
Pulse Oximetry—A Perioperative Perspective
by Kellie Moon, Naema Daino, Paula Gomez, Juan Arias, Ammar Toubasi and Sri Varsha Pulijal
Diagnostics 2026, 16(12), 1812; https://doi.org/10.3390/diagnostics16121812 - 12 Jun 2026
Viewed by 687
Abstract
Pulse oximetry is an essential standard monitor in modern anesthetic practice, enabling continuous noninvasive assessment of arterial oxygen saturation and pulse rate throughout the perioperative period. Since its introduction into clinical medicine, pulse oximetry has significantly improved patient safety by facilitating early detection [...] Read more.
Pulse oximetry is an essential standard monitor in modern anesthetic practice, enabling continuous noninvasive assessment of arterial oxygen saturation and pulse rate throughout the perioperative period. Since its introduction into clinical medicine, pulse oximetry has significantly improved patient safety by facilitating early detection of hypoxemia and physiologic deterioration. Despite its widespread use, clinicians may underrecognize the technical principles, physiologic assumptions, and limitations that influence measurement accuracy. This review provides a perioperative perspective on pulse oximetry, including the physics of photoplethysmography, sensor technologies, and practical considerations for optimal probe placement and signal acquisition. Sources of inaccuracy such as motion artifact, low perfusion states, dyshemoglobinemias, ambient light interference, skin pigmentation, and venous pulsation are discussed in detail. The review further examines perioperative applications across preoperative evaluation, intraoperative monitoring, and postoperative recovery, while also exploring advanced parameters including perfusion index (PI) and pleth variability index (PVI). Emerging innovations such as multi-wavelength systems and artificial intelligence (AI)-enhanced signal analysis are also highlighted. A comprehensive understanding of pulse oximetry allows anesthesiologists to appropriately interpret monitor data, recognize device limitations, and optimize perioperative patient care. Full article
(This article belongs to the Section Point-of-Care Diagnostics and Devices)
Show Figures

Figure 1

21 pages, 2592 KB  
Article
Diagnostic Performance and Trending Ability of Continuous Non-Invasive Hemoglobin Monitoring During Elective Intracranial Neurosurgery with Invasive Arterial Monitoring: Influence of Anesthetic Technique
by Hatice Eyiol and Oguzhan Arun
Diagnostics 2026, 16(5), 673; https://doi.org/10.3390/diagnostics16050673 - 26 Feb 2026
Viewed by 499
Abstract
Background: Continuous non-invasive hemoglobin monitoring (SpHb) may provide real-time information during surgery, but its accuracy in neurosurgery remains uncertain. We evaluated the agreement, trending ability, and diagnostic performance of SpHb compared with arterial blood gas hemoglobin during elective intracranial neurosurgery. Methods: In this [...] Read more.
Background: Continuous non-invasive hemoglobin monitoring (SpHb) may provide real-time information during surgery, but its accuracy in neurosurgery remains uncertain. We evaluated the agreement, trending ability, and diagnostic performance of SpHb compared with arterial blood gas hemoglobin during elective intracranial neurosurgery. Methods: In this prospective observational study, 60 adults undergoing elective neurosurgery with invasive arterial monitoring were included. SpHb (Masimo Radical-7) was compared with paired arterial hemoglobin values. Agreement was assessed using repeated-measures Bland–Altman analysis and mixed-effects modeling. Trending ability was evaluated using four-quadrant concordance with an exclusion zone of ±0.5 g/dL. Discrimination for severe anemia (Hb < 8 g/dL) was assessed using ROC analysis with patient-level cluster bootstrapping. Results: A total of 190 paired measurements were analyzed. Mean bias was +0.23 g/dL, with wide limits of agreement (−3.26 to +3.72 g/dL). Agreement was worse under low-perfusion-index conditions. Trending performance was preserved, with an overall concordance rate of 85.5%. SpHb showed moderate discrimination for severe anemia (AUC 0.78; 95% CI 0.61–0.93), although severe anemia events were infrequent. Conclusions: SpHb showed limited reliability for absolute hemoglobin quantification during neurosurgery but provided useful trend information. SpHb should not replace invasive hemoglobin measurements for clinical decision-making. Full article
(This article belongs to the Section Point-of-Care Diagnostics and Devices)
Show Figures

Figure 1

23 pages, 3207 KB  
Article
Is Pulse Co-Oximetry a Reliable Alternative to Invasive Hemoglobin Measurement in Pediatric Neurosurgical Procedures?
by Funda Arun and Oguzhan Arun
Children 2026, 13(3), 323; https://doi.org/10.3390/children13030323 - 25 Feb 2026
Viewed by 1020
Abstract
Background/Objectives: Pediatric neurosurgical procedures often involve significant blood loss and rapid hemodynamic shifts, necessitating accurate hemoglobin (Hb) monitoring. While continuous non-invasive Hb (SpHb) monitoring offers real-time trending, its accuracy in high-risk pediatric populations remains debated. We aimed to evaluate the diagnostic accuracy and [...] Read more.
Background/Objectives: Pediatric neurosurgical procedures often involve significant blood loss and rapid hemodynamic shifts, necessitating accurate hemoglobin (Hb) monitoring. While continuous non-invasive Hb (SpHb) monitoring offers real-time trending, its accuracy in high-risk pediatric populations remains debated. We aimed to evaluate the diagnostic accuracy and clinical utility of SpHb compared to invasive arterial blood gas (ABG) analysis in pediatric patients undergoing cranial and spinal surgeries. Methods: This prospective, observational study enrolled 60 pediatric patients (aged 0–16 years) scheduled for high-risk neurosurgery. SpHb was measured continuously and compared with intermittent ABG-Hb values. Statistical analysis included Bland–Altman agreement, Pearson’s correlation, and Error Grid Analysis. Subgroup analyses assessed the impact of the Perfusion Index (PI), hypotension, and metabolic acidosis on device performance. Results: Data from 57 patients (median age: 12 months, interquartile range: 6–42 months; 70.2% aged <24 months) were analyzed. SpHb demonstrated a moderate correlation with ABG-Hb (r = 0.567, p < 0.001) but exhibited systematic overestimation with a mean bias of +1.60 ± 1.54 g/dL. Crucially, SpHb showed 0% sensitivity for detecting critical anemia (Hb < 8.0 g/dL). Device performance was significantly compromised by physiological extremes: severe metabolic acidosis significantly increased bias to +2.27 g/dL (p = 0.038), and intraoperative hypotension significantly widened the limits of agreement (SD of bias: 1.79 g/dL vs. 1.45 g/dL in normotension). Furthermore, hemodynamic analysis revealed a loss of autoregulation during hypotension, where the pressure-perfusion coupling strengthened (r = 0.44) compared to the normotensive state (r = 0.15). Conclusions: SpHb monitoring provides fair Hb trending but is limited by systematic overestimation and poor sensitivity for critical anemia. Accuracy worsens during severe acidosis and hemodynamic instability. Therefore, SpHb should function as a complementary “early warning” trend monitor rather than a sole transfusion trigger, with invasive validation remaining essential for intraoperative decision-making. Full article
(This article belongs to the Section Pediatric Surgery)
Show Figures

Figure 1

11 pages, 517 KB  
Article
Pulse Oximetry Histogram Profiles Before and After Red Blood Cell Transfusion in Very Preterm Infants: A Prospective Observational Cohort
by Nevra Çolak, Murat Konak and Saime Sündüs Uygun
Children 2026, 13(2), 167; https://doi.org/10.3390/children13020167 - 25 Jan 2026
Viewed by 750
Abstract
Background/Objectives: Red blood cell (RBC) transfusion is frequently used to treat anemia of prematurity, yet bedside metrics that capture its short-term impact on oxygenation stability are limited. We assessed whether pulse oximetry histogram-derived oxygen saturation (SpO2) exposure changes after transfusion and [...] Read more.
Background/Objectives: Red blood cell (RBC) transfusion is frequently used to treat anemia of prematurity, yet bedside metrics that capture its short-term impact on oxygenation stability are limited. We assessed whether pulse oximetry histogram-derived oxygen saturation (SpO2) exposure changes after transfusion and whether responses differ across clinical subgroups. Methods: This prospective observational cohort included preterm infants born <32 weeks’ gestation who received a standardized RBC transfusion (15 mL/kg). Continuous SpO2 histograms quantified the percentage of monitored time spent in hypoxemia (<85%), normoxemia (86–95%), and hyperoxemia (≥96%) during four intervals: 24 h pre-transfusion and 24, 48, and 72 h post-transfusion. Repeated-measures and subgroup analyses (BPD, sex, birth weight < 1000 g) were performed. Results: Thirty-three infants were analyzed (gestational age 29.4 ± 2.1 weeks; birth weight 1220.6 ± 316.9 g). Hemoglobin increased from 8.6 ± 1.1 to 11.7 ± 1.0 g/dL (p < 0.001). Cohort-level histogram shifts were modest: normoxemia increased from 68.4 ± 12.1% to 72.6 ± 11.4% at 24 h (p = 0.18), hypoxemia decreased from 10.3 ± 6.5% to 6.6 ± 4.8% (p = 0.09), and hyperoxemia remained stable (21.3 ± 9.2% to 20.8 ± 8.5%; p = 0.44). Infants with BPD and those <1000 g showed persistently higher hypoxemia and/or hyperoxemia at 72 h compared with counterparts. Exploratory ROC analyses showed modest discrimination of 24 h hypoxemia for ROP (AUC 0.71) and 72 h hyperoxemia for BPD (AUC 0.74). Conclusions: RBC transfusion corrected anemia but did not produce a consistent cohort-level improvement in SpO2 histogram stability. Histogram metrics may help characterize heterogeneous oxygenation responses and support hypothesis generation for individualized monitoring strategies. Full article
Show Figures

Figure 1

10 pages, 981 KB  
Case Report
First Symptomatic Pediatric Case of Hb Rothschild (HBB: c.112T>C, p.Trp38Arg): Low-Oxygen-Affinity Hemoglobin Presenting with Persistent Pseudohypoxemia
by Ekaterina Nuzhnaya, Andrey Marakhonov, Artem Ivanov, Yulia Lashkova, Ivan Kuznetsov, Tatiana Kulichenko, Ksenya Zabudskaya, Oxana Ryzhkova, Nikolay Zernov and Natalia Semenova
Diagnostics 2025, 15(24), 3181; https://doi.org/10.3390/diagnostics15243181 - 12 Dec 2025
Viewed by 745
Abstract
Background: Hemoglobin Rothschild (Hb Rothschild), NM_000518.5(HBB):c.112T>C, is an ultra-rare low-oxygen-affinity hemoglobin variant that persistently causes reduced peripheral oxygen saturation on pulse oximetry despite normal arterial oxygenation. Fewer than ten cases have been reported worldwide, and only one involved a child—an [...] Read more.
Background: Hemoglobin Rothschild (Hb Rothschild), NM_000518.5(HBB):c.112T>C, is an ultra-rare low-oxygen-affinity hemoglobin variant that persistently causes reduced peripheral oxygen saturation on pulse oximetry despite normal arterial oxygenation. Fewer than ten cases have been reported worldwide, and only one involved a child—an asymptomatic carrier identified incidentally. Methods: The patient underwent clinical examination, growth assessment, blood tests, hemoglobin electrophoresis, chest CT, abdominal ultrasound, echocardiography, and pulmonary perfusion scintigraphy. Whole genome sequencing (WGS) of the proband and parents was performed, followed by bioinformatic analysis and ACMG-based variant interpretation. A PRISMA-guided PubMed literature review was conducted. Results: We report on the first pediatric case exhibiting a symptomatic clinical course. A 4-year-old boy was referred for chronically low peripheral oxygen saturation (SpO2), 78–86%, on pulse oximetry and recurrent lower respiratory tract infections. Early developmental history revealed episodes of apnea in infancy, perioral cyanosis, poor exercise tolerance, and low weight gain. Repeated cardiopulmonary assessments, chest computed tomography (CT), echocardiography, and pulmonary perfusion scintigraphy yielded unremarkable findings. Arterial blood gas analysis consistently showed normal arterial partial pressure of oxygen (PaO2), excluding true hypoxemia. Hemoglobin electrophoresis revealed an abnormal HbD fraction; WGS identified a heterozygous variant NM_000518.5(HBB):c.112T>C inherited from the patient’s asymptomatic father. This variant increases the partial pressure of oxygen at which hemoglobin is 50% saturated (p50), thereby decreasing hemoglobin’s oxygen affinity and shifting the oxyhemoglobin dissociation curve to the right. These alterations explain the discordance between low peripheral oxygen saturation (SpO2) and preserved oxygen delivery to tissues. Conclusions: This case expands the clinical spectrum of Hb Rothschild and demonstrates that symptomatic presentation may occur in early childhood. Awareness of low-affinity hemoglobin variants is essential to avoid misdiagnosis and unnecessary cardiopulmonary interventions. Early genetic testing facilitates accurate diagnosis and appropriate counseling. Full article
(This article belongs to the Special Issue Insights into Pediatric Genetics)
Show Figures

Figure 1

10 pages, 521 KB  
Review
Critical Narrative Review of the Applications of Near-Infrared Spectroscopy Technology in Sports Science
by Carlos Sendra-Pérez, Alberto Encarnación-Martínez and Jose I. Priego-Quesada
Sensors 2025, 25(21), 6798; https://doi.org/10.3390/s25216798 - 6 Nov 2025
Cited by 2 | Viewed by 2054
Abstract
Near-Infrared Spectroscopy (NIRS) is a noninvasive technology used to monitor muscle oxygenation in sports science. Since its introduction in 1977, NIRS has evolved into a valuable tool for assessing physiological responses during exercise and rehabilitation. The history of NIRS dates back to early [...] Read more.
Near-Infrared Spectroscopy (NIRS) is a noninvasive technology used to monitor muscle oxygenation in sports science. Since its introduction in 1977, NIRS has evolved into a valuable tool for assessing physiological responses during exercise and rehabilitation. The history of NIRS dates back to early hemoglobin studies in the 19th century, with significant advancements in pulse oximetry during World War II. By the late 1980s, NIRS had become widely used in sports science, allowing researchers to evaluate muscle perfusion and metabolic thresholds in various activities. NIRS applications in sports include determining exercise thresholds, monitoring muscle oxygenation during training, assessing asymmetries between limbs, and evaluating mitochondrial capacity. Studies have explored its use in both team and endurance sports, highlighting its role in optimizing performance and preventing injuries. Beyond sports, NIRS technology is expanding into clinical fields, aiding in rehabilitation and patient monitoring. This critical review has identified several key areas for future research, including the need to clarify methodological influences, strategies to minimize the impact of adipose tissue on NIRS measurements, the importance of conducting longitudinal studies, increased research on sex-specific effects, and a greater emphasis on field-based studies. With continued advancements, NIRS is expected to further enhance our understanding of muscle physiology and human performance, making it a crucial tool in athletic performance assessment and clinical practice. Full article
Show Figures

Figure 1

13 pages, 1651 KB  
Article
Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67TM (Masimo)
by Philipp Helmer, Andreas Steinisch, Sebastian Hottenrott, Tobias Schlesinger, Michael Sammeth, Patrick Meybohm and Peter Kranke
Diagnostics 2025, 15(2), 128; https://doi.org/10.3390/diagnostics15020128 - 8 Jan 2025
Cited by 8 | Viewed by 5313
Abstract
Background: Hemoglobin (Hb) is a crucial parameter in perioperative care due to its essential role for oxygen transport and tissue oxygenation. Accurate Hb monitoring allows for timely interventions to address perioperative anemia and, thus, prevent morbidity and mortality. Traditional Hb measurements rely [...] Read more.
Background: Hemoglobin (Hb) is a crucial parameter in perioperative care due to its essential role for oxygen transport and tissue oxygenation. Accurate Hb monitoring allows for timely interventions to address perioperative anemia and, thus, prevent morbidity and mortality. Traditional Hb measurements rely on invasive blood sampling, which significantly contributes to iatrogenic anemia and poses discomfort and increased infection risks. The advent of non-invasive devices like Masimo’s Rad-67™, which measures Hb using pulse CO-oximetry (SpHb), offers a promising alternative. This study evaluates the accuracy of SpHb compared to clinical standard blood gas analysis (BGA) in perioperative patients. Methods: This retrospective study analyzed 335 paired Hb measurements with an interval <15 min between SpHb and BGA in the operating theater and post-anesthesia care unit of a university hospital. Patients experiencing hemodynamic instability, acute bleeding, or critical care were excluded. Statistical analysis included Bland–Altman plots and Pearson correlation coefficients (PCCs) to assess the agreement between SpHb and BGA. Potential confounders, e.g., patient age, skin temperature, sex, perfusion index (PI), and atrial fibrillation, were also analyzed. Results: The bias of the SpHb compared to BGA according to Bland–Altman was 0.00 g/dL, with limits of agreement ranging from −2.70 to 2.45 g/dL. A strong correlation was observed (r = 0.79). Overall, 57.6% of the paired measurements showed a deviation between the two methods of ≤±1 g/dL; however, this applied to only 33.3% of the anemic patients. Modified Clark’s Error Grid analysis showed 85.4% of values fell within clinically acceptable limits. Sex was found to have a statistically significant, but not clinically relevant, effect on accuracy (p = 0.02). Conclusions: The Rad-67TM demonstrates reasonable accuracy for non-invasive SpHb, but exhibits significant discrepancies in anemic patients with overestimating low values. While it offers potential for reducing iatrogenic blood loss, SpHb so far should not replace BGA in critical clinical decision-making. Full article
(This article belongs to the Special Issue Wearable Sensors for Health Monitoring and Diagnostics)
Show Figures

Figure 1

12 pages, 901 KB  
Article
Correlation of Blood Hemoglobin Values with Non-Invasive Co-Oximetry Measurement of SpHb in Dogs Undergoing Elective Ovariohysterectomy
by María Fernanda Espinosa-Morales, Agatha Elisa Miranda-Cortés, Daniel Mota-Rojas, Alejandro Casas-Alvarado, Alejandro Jiménez-Yedra, Alicia Pamela Pérez-Sánchez and Ismael Hernández-Ávalos
Animals 2024, 14(6), 822; https://doi.org/10.3390/ani14060822 - 7 Mar 2024
Cited by 2 | Viewed by 3553
Abstract
Cardiovascular function monitoring has been suggested as a key parameter to determine patient stability during the anesthetic process. However, the use of pulse co-oximetry has been suggested as a technology to complement the monitoring of this system as a direct way to assess [...] Read more.
Cardiovascular function monitoring has been suggested as a key parameter to determine patient stability during the anesthetic process. However, the use of pulse co-oximetry has been suggested as a technology to complement the monitoring of this system as a direct way to assess hemoglobin (Hb) blood concentration. Therefore, this study aimed to correlate and determine the measurement bias between Hb blood levels with continuously determined blood hemoglobin concentration (SpHb) and arterial oxygen content values (SpOC), both obtained by noninvasive co-oximetry in dogs undergoing elective ovariohysterectomy (OVH). A total of 85 clinically healthy bitches of different breeds that were admitted for elective OVH surgery were evaluated. These animals underwent SpHb and SpOC capture after the in vivo setting for the duration of the surgical procedure. Likewise, five minutes before the end of the surgical procedure, a blood sample was obtained directly from the jugular vein to determine the blood concentration of Hb (HbLAB). The Bland–Altman analysis showed 95% limits of agreement from −4.22 to 4.99 g/dL with a BIAS (mean difference) of 0.384 ± 2.35 g/dL (r = 0.401). SpHb recordings were correlated with oxygen saturation (SpO2) (r = 0.995), SpOC (r = 0.992) and with perfusion index (PI) (r = 0.418). Therefore, SpHb presents a moderate positive correlation with direct blood concentration of Hb. This possibly shows that continuous measurement of SpHb by noninvasive co-oximetry is a reliable and advanced alternative for monitoring Hb concentration in dogs under anesthesia. Full article
Show Figures

Figure 1

15 pages, 3471 KB  
Article
Evaluation and Performance of a Positive Airway Pressure Device (CPAP-AirFlife™): A Randomized Crossover Non-Inferiority Clinical Study in Normal Subjects
by Héctor A. Tinoco, Luis Perdomo-Hurtado, Joismer A. Henao-Cruz, José F. Escobar-Serna, Oscar Jaramillo-Robledo, Oscar D. Aguirre-Ospina, Mateo Hurtado-Hernández and Juliana Lopez-Guzman
Medicina 2023, 59(8), 1372; https://doi.org/10.3390/medicina59081372 - 27 Jul 2023
Cited by 1 | Viewed by 3694
Abstract
Background and Objectives: During the COVID-19, the demand for non-invasive ventilatory support equipment significantly increased. In response, a novel non-invasive ventilatory support model called CPAP-AirFlife™ was developed utilizing existing technologies. This model offers technological advantages, including an aerosol-controlled helmet suitable for high-risk [...] Read more.
Background and Objectives: During the COVID-19, the demand for non-invasive ventilatory support equipment significantly increased. In response, a novel non-invasive ventilatory support model called CPAP-AirFlife™ was developed utilizing existing technologies. This model offers technological advantages, including an aerosol-controlled helmet suitable for high-risk environments such as ambulances. Additionally, it is cost-effective and does not require medical air, making it accessible for implementation in low-level hospitals, particularly in rural areas. This study aimed to assess the efficacy of CPAP-AirFlife™ by conducting a non-inferiority comparison with conventional ventilation equipment used in the Intensive Care Unit. Materials and Methods: A clinical study was conducted on normal subjects in a randomized and sequential manner. Parameters such as hemoglobin oxygen saturation by pulse oximetry, exhaled PCO2 levels, vital signs, and individual tolerance were compared between the CPAP-AirFlife™ and conventional equipment. The study population was described in terms of demographic characteristics and included in the analysis. Results: It was shown that the CPAP-AirFlife™ was not inferior to conventional equipment in terms of efficacy or tolerability. Hemoglobin oxygen saturation levels, exhaled PCO2 levels, vital signs, and individual tolerance did not significantly differ between the two models. Conclusions: The findings suggest that CPAP-AirFlife™ is a practical and cost-effective alternative for non-invasive ventilatory support. Its technological advantages, including the aerosol-controlled helmet, make it suitable for high-risk environments. The device’s accessibility and affordability make it a promising solution for implementation in low-level hospitals, particularly in rural areas. This study supports using CPAP-AirFlife™ as a practical option for non-invasive ventilatory support, providing a valuable contribution to respiratory care during the COVID-19 pandemic and beyond. Full article
Show Figures

Figure 1

7 pages, 918 KB  
Case Report
Methemoglobinemia Secondary to Inhalation of Automobile Emissions with Suicide Motivations
by Manuel Antonio Tazón-Varela, Ángel Padilla-Mielgo, Raquel Villaverde-Plazas, Fabiola Espinoza-Cuba, Nekane Gallo-Salazar and Pedro Muñoz-Cacho
J. Clin. Med. 2023, 12(3), 734; https://doi.org/10.3390/jcm12030734 - 17 Jan 2023
Cited by 4 | Viewed by 2940
Abstract
Background: Methemoglobinemia (MetHb) is a rare and potentially severe dyshemoglobinemia that can be induced by exposure to oxidizing agents, decreasing the functional capacity of the hemoglobin molecule to transport and release oxygen into the tissues. MetHb can originate from gases with oxidizing capacity [...] Read more.
Background: Methemoglobinemia (MetHb) is a rare and potentially severe dyshemoglobinemia that can be induced by exposure to oxidizing agents, decreasing the functional capacity of the hemoglobin molecule to transport and release oxygen into the tissues. MetHb can originate from gases with oxidizing capacity generated by internal combustion engines, although since the universalization of catalyst converters in automobiles, a tiny proportion of MetHb poisoning is due to exposure to engine gases and fumes. Within this group, only two cases due to suicidal motivations have been reported in the last 30 years. Case presentation: Here, we expose the case of a patient with MetHb levels of 25.2% (normal 0–1.5%) who with suicidal motivations had attached and locked a hose to the exhaust pipe of her vehicle with electrical tape, becoming exposed to a sustained concentration of the vehicle’s exhaust. Upon her arrival at the emergency department, the presence of generalized greyish cyanosis with alterations of the sensorium, dissociation between saturation measured by arterial blood gas analysis and pulse oximetry (98% vs. 85%), no response to high-flow oxygen therapy, and an excellent response to intravenous methylene blue treatment were highlighted. Conclusions: This report illustrates an original case of acute toxic acquired MetHb due to inhalation of oxidizing substances originating from the bad ignition of an internal combustion engine. When evaluating a patient with suspected gas intoxication, we usually consider poisoning by the most common toxins, such as carbon monoxide or cyanide. In this context, we propose an algorithm to assist in the suspicion of this entity in patients with cyanosis in the emergency department. MetHb poisoning should be suspected, and urgent co-oximetry should be requested when there is no congruence between cyanosis intensity and oxygen saturation measured by pulse oximetry, if there is discordance between the results of oxygen saturation measured by arterial blood gas and pulse oximeter, and if there is no response to oxygen treatment. This algorithm could be useful to not delay diagnosis, improve prognosis, and limit potential sequelae. Full article
(This article belongs to the Section Emergency Medicine)
Show Figures

Figure 1

11 pages, 2752 KB  
Article
Hemoglobin Determination Using Pulse Co-Oximetry and Reduced-Volume Blood Gas Analysis in the Critically Ill: A Prospective Cohort Study
by Piotr F. Czempik, Michał P. Pluta and Łukasz J. Krzych
Diagnostics 2022, 12(12), 2908; https://doi.org/10.3390/diagnostics12122908 - 22 Nov 2022
Cited by 6 | Viewed by 3993
Abstract
Hospital-acquired anemia is common in patients hospitalized in the intensive care unit (ICU). A major source of iatrogenic blood loss in the ICU is the withdrawal of blood for laboratory testing. The aim of our study was to analyze the feasibility and accuracy [...] Read more.
Hospital-acquired anemia is common in patients hospitalized in the intensive care unit (ICU). A major source of iatrogenic blood loss in the ICU is the withdrawal of blood for laboratory testing. The aim of our study was to analyze the feasibility and accuracy of non-invasive spot-check pulse co-oximetry (SpHb), and a reduced-volume blood gas analysis (ABG Hb) for the determination of Hb concentration in critically ill patients. Comparisons between Hb determined with test devices and the gold standard—complete blood count (CBC)—were performed using Bland–Altman analysis and concordance correlation coefficient (CCC). The limits of agreement between SpHb and CBC Hb were –2.0 [95%CI −2.3–(−1.7)] to 3.6 (95%CI 3.3–3.9) g/dL. The limits of agreement between ABG Hb and CBC Hb were −0.6 [95%CI −0.7–(−0.4)] to 2.0 (95%CI 1.9–2.2) g/dL. Spearman’s coefficient and CCC between ABG Hb and CBC Hb were 0.96 (95%CI 0.95–0.97, p < 0.001) and 0.91 (95%CI 0.88–0.92), respectively. Non-invasive spot-check Hb co-oximetry is not sufficiently accurate for the monitoring of hemoglobin concentration in critically ill patients. Reduced volume arterial blood gas analysis has acceptable accuracy and could replace complete blood count for the monitoring of Hb concentration in critically ill patients, leading to a significant reduction in blood volume lost for anemia diagnostics. Full article
(This article belongs to the Section Clinical Laboratory Medicine)
Show Figures

Figure 1

10 pages, 1573 KB  
Article
Impact of Increased End-Tidal Carbon Dioxide on Continuous Noninvasive Hemoglobin Monitoring during Laparoscopic Gastrectomy: A Randomized Controlled Study
by Ha-Yeon Kim, Jong-Bum Choi, Sang-Uk Han, Hye-Sun Lee, Kyuhyeok Lee and Ji-Eun Kim
J. Pers. Med. 2022, 12(2), 160; https://doi.org/10.3390/jpm12020160 - 26 Jan 2022
Cited by 1 | Viewed by 2847
Abstract
The pulse CO-Oximetry allows continuous, noninvasive monitoring of hemoglobin (SpHb). We assessed the impact of increased end-tidal carbon dioxide (EtCO2) on the accuracy and trending ability of SpHb in laparoscopic surgery. Participants (n = 64) were randomly allocated to the [...] Read more.
The pulse CO-Oximetry allows continuous, noninvasive monitoring of hemoglobin (SpHb). We assessed the impact of increased end-tidal carbon dioxide (EtCO2) on the accuracy and trending ability of SpHb in laparoscopic surgery. Participants (n = 64) were randomly allocated to the low carbon dioxide (CO2) group (EtCO2: 30–35 mmHg) or the high CO2 group (EtCO2: 40–45 mmHg). The SpHb and laboratory hemoglobin (tHb) were obtained during surgery. The correlation coefficient (r) between SpHb and tHb showed greater tendency in the low CO2 group (r = 0.68) than in the high CO2 group (r = 0.43). The bias (precision) was −1.18 (1.09) with a limit of agreement (LOA) of −3.31 to 0.95 in low CO2 group and −1.02 (1.24) with a LOA of −3.45 to 1.42 in high CO2 group; they did not differ significantly between the groups (p = 0.246). The low CO2 group showed a high concordance rate of 95.9% and a moderate correlation between ΔSpHb and ΔtHb (r = 0.53). However, the high CO2 group showed a concordance rate of 77.8% and no correlation between ΔSpHb and ΔtHb (r = 0.11). In conclusion, increased EtCO2 significantly reduced the trending ability of SpHb during laparoscopic surgery. Caution should be executed when interpreting SpHb values during laparoscopic surgery in patients with hypercapnia. Full article
Show Figures

Figure 1

15 pages, 2862 KB  
Article
The Oxygen Transport Triad in High-Altitude Pulmonary Edema: A Perspective from the High Andes
by Gustavo Zubieta-Calleja and Natalia Zubieta-DeUrioste
Int. J. Environ. Res. Public Health 2021, 18(14), 7619; https://doi.org/10.3390/ijerph18147619 - 17 Jul 2021
Cited by 13 | Viewed by 8524
Abstract
Acute high-altitude illnesses are of great concern for physicians and people traveling to high altitude. Our recent article “Acute Mountain Sickness, High-Altitude Pulmonary Edema and High-Altitude Cerebral Edema, a View from the High Andes” was questioned by some sea-level high-altitude experts. As a [...] Read more.
Acute high-altitude illnesses are of great concern for physicians and people traveling to high altitude. Our recent article “Acute Mountain Sickness, High-Altitude Pulmonary Edema and High-Altitude Cerebral Edema, a View from the High Andes” was questioned by some sea-level high-altitude experts. As a result of this, we answer some observations and further explain our opinion on these diseases. High-Altitude Pulmonary Edema (HAPE) can be better understood through the Oxygen Transport Triad, which involves the pneumo-dynamic pump (ventilation), the hemo-dynamic pump (heart and circulation), and hemoglobin. The two pumps are the first physiologic response upon initial exposure to hypobaric hypoxia. Hemoglobin is the balancing energy-saving time-evolving equilibrating factor. The acid-base balance must be adequately interpreted using the high-altitude Van Slyke correction factors. Pulse-oximetry measurements during breath-holding at high altitude allow for the evaluation of high altitude diseases. The Tolerance to Hypoxia Formula shows that, paradoxically, the higher the altitude, the more tolerance to hypoxia. In order to survive, all organisms adapt physiologically and optimally to the high-altitude environment, and there cannot be any “loss of adaptation”. A favorable evolution in HAPE and pulmonary hypertension can result from the oxygen treatment along with other measures. Full article
Show Figures

Figure 1

11 pages, 893 KB  
Review
Accuracy of Pulse Oximetry in the Presence of Fetal Hemoglobin—A Systematic Review
by Ena Pritišanac, Berndt Urlesberger, Bernhard Schwaberger and Gerhard Pichler
Children 2021, 8(5), 361; https://doi.org/10.3390/children8050361 - 30 Apr 2021
Cited by 21 | Viewed by 10009
Abstract
Continuous monitoring of arterial oxygen saturation by pulse oximetry (SpO2) is the main method to guide respiratory and oxygen support in neonates during postnatal stabilization and after admission to neonatal intensive care unit. The accuracy of these devices is therefore crucial. The presence [...] Read more.
Continuous monitoring of arterial oxygen saturation by pulse oximetry (SpO2) is the main method to guide respiratory and oxygen support in neonates during postnatal stabilization and after admission to neonatal intensive care unit. The accuracy of these devices is therefore crucial. The presence of fetal hemoglobin (HbF) in neonatal blood might affect SpO2 readings. We performed a systematic qualitative review to investigate the impact of HbF on SpO2 accuracy in neonates. PubMed/Medline, Embase, Cumulative Index to Nursing & Allied Health database (CINAHL) and Cochrane library databases were searched from inception to January 2021 for human studies in the English language, which compared arterial oxygen saturations (SaO2) from neonatal blood with SpO2 readings and included HbF measurements in their reports. Ten observational studies were included. Eight studies reported SpO2-SaO2 bias that ranged from −3.6%, standard deviation (SD) 2.3%, to +4.2% (SD 2.4). However, it remains unclear to what extent this depends on HbF. Five studies showed that an increase in HbF changes the relation of partial oxygen pressure (paO2) to SpO2, which is physiologically explained by the leftward shift in oxygen dissociation curve. It is important to be aware of this shift when treating a neonate, especially for the lower SpO2 limits in preterm neonates to avoid undetected hypoxia. Full article
(This article belongs to the Special Issue Stabilization and Resuscitation of Newborns)