Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = graphene diaphragm

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 5740 KB  
Article
Fabrication and Characterization of Diaphragm Headphones Based on Graphene Nanocomposites
by Shun-Fa Hwang, Hsien-Kuang Liu, Wei-Chong Liao and Yi Kai Cheng
Materials 2024, 17(4), 933; https://doi.org/10.3390/ma17040933 - 17 Feb 2024
Cited by 1 | Viewed by 2819
Abstract
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then, vacuum bag molding is used to [...] Read more.
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then, vacuum bag molding is used to fabricate GOPC from GOP. Hot pressing and associated molds are adopted to fabricate line-indented (GOPC-L) or curve-indented patterns (GOPC-C) on the GOPC. The performances of one kind of GOP and three kinds of GOPC diaphragm headphones are analyzed based on their sound pressure level (SPL) curves achieved by the Soundcheck measurement system. There are four important processing parameters that will influence the performance of the diaphragm, including material type GOP versus GOPC, indented pattern type, sonication time on suspension, and graphene weight fraction in suspension. Compliances of various diaphragms are measured by the Klippel LPM laser measurement system. The results indicate that effects of sonication time and graphene weight fraction on SPL of GOP and GOPC headphones are in reverse, and this is associated with their difference on compliance (modulus), mass, damping ratio, and microstructure uniformity. Either GOPC-L or GOPC-C seems to improve the microstructure of the GOPC, and leads to better SPL performance. The correlation between the previous four factors and SPLs of four kinds of diaphragm headphones is proposed by using scanning electron microscope (SEM) to examine the microstructure of these diaphragms. Full article
Show Figures

Figure 1

19 pages, 6323 KB  
Article
Design and Optimization of a Pressure Sensor Based on Serpentine-Shaped Graphene Piezoresistors for Measuring Low Pressure
by Xincheng Ren, Xianyun Liu, Xin Su and Xingfang Jiang
Sensors 2022, 22(13), 4937; https://doi.org/10.3390/s22134937 - 30 Jun 2022
Cited by 16 | Viewed by 5556
Abstract
This thesis describes a novel microelectromechanical system (MEMS) piezoresistive pressure sensor based on serpentine-shaped graphene piezoresistors paired with trapezoidal prisms under the diaphragm for measuring low pressure. The finite element method (FEM) is utilized to analyze the mechanical stress and membrane deflection to [...] Read more.
This thesis describes a novel microelectromechanical system (MEMS) piezoresistive pressure sensor based on serpentine-shaped graphene piezoresistors paired with trapezoidal prisms under the diaphragm for measuring low pressure. The finite element method (FEM) is utilized to analyze the mechanical stress and membrane deflection to enhance the degree of stress concentration in this unique sensor. The functional relationship between mechanical performance and dimension variables is established after using the curve fitting approach to handle the stress and deflection. Additionally, the Taguchi optimization method is employed to identify the best dimensions for the proposed structure. Then, the suggested design is compared to the other three designs in terms of operating performance. It is revealed that the recommended sensor can significantly improve sensitivity while maintaining extremely low nonlinearity. In this study, three different types of serpentine-shaped graphene piezoresistors are also designed, and their sensing capability is compared to silicon. The simulation results indicate that the pressure sensor with Type 2 graphene piezoresistors has a maximum sensitivity of 24.50 mV/psi and ultra-low nonlinearity of 0.06% FSS in the pressure range of 0–3 psi. Full article
(This article belongs to the Collection Modeling, Testing and Reliability Issues in MEMS Engineering)
Show Figures

Graphical abstract

13 pages, 3004 KB  
Article
Evaluating a Human Ear-Inspired Sound Pressure Amplification Structure with Fabry–Perot Acoustic Sensor Using Graphene Diaphragm
by Cheng Li, Xi Xiao, Yang Liu and Xuefeng Song
Nanomaterials 2021, 11(9), 2284; https://doi.org/10.3390/nano11092284 - 2 Sep 2021
Cited by 8 | Viewed by 4282
Abstract
In order to enhance the sensitivity of a Fabry–Perot (F-P) acoustic sensor without the need of fabricating complicated structures of the acoustic-sensitive diaphragm, a mini-type external sound pressure amplification structure (SPAS) with double 10 μm thickness E-shaped diaphragms of different sizes interconnected with [...] Read more.
In order to enhance the sensitivity of a Fabry–Perot (F-P) acoustic sensor without the need of fabricating complicated structures of the acoustic-sensitive diaphragm, a mini-type external sound pressure amplification structure (SPAS) with double 10 μm thickness E-shaped diaphragms of different sizes interconnected with a 5 mm length tapered circular rod was developed based on the acoustic sensitive mechanism of the ossicular chain in the human middle ear. The influence of thickness and Young’s modulus of the two diaphragms with the diameters of 15 mm and 3 mm, respectively, on the amplification ratio and frequency response were investigated via COMSOL acoustic field simulation, thereby confirming the dominated effect. Then, three kinds of dual-diaphragm schemes relating to steel and thermoplastic polyurethanes (TPU) materials were introduced to fabricate the corresponding SPASs. The acoustic test showed that the first scheme achieved a high resonant response frequency with lower acoustic amplification due to strong equivalent stiffness; in contrast, the second scheme offered a high acoustic amplification but reduced frequency range. As a result of sensitivity enhancement, adapted with the steel/TPU diaphragm structure, an optical fiber Fabry–Perot sensor using a multilayer graphene diaphragm with a diameter of 125 μm demonstrated a remarkable sensitivity of 565.3 mV/Pa @1.2 kHz due to the amplification ratio of up to ~29.9 in the range of 0.2–2.3 kHz, which can be further improved by miniaturizing structure dimension, along with the use of microstructure packaging technology. Full article
(This article belongs to the Special Issue Nanotechnologies and Nanomaterials: Selected Papers from CCMR)
Show Figures

Figure 1

11 pages, 11117 KB  
Article
A Large-Area and Nanoscale Graphene Oxide Diaphragm-Based Extrinsic Fiber-Optic Fabry–Perot Acoustic Sensor Applied for Partial Discharge Detection in Air
by Shuchao Wang and Weigen Chen
Nanomaterials 2020, 10(11), 2312; https://doi.org/10.3390/nano10112312 - 22 Nov 2020
Cited by 30 | Viewed by 3857
Abstract
This article presents an extrinsic fiber-optic acoustic sensor applied for partial discharge (PD) detection in air. A Fabry–Perot (F-P) cavity consisting of a single-mode fiber (SMF) and a graphene oxide (GO) film, whose thickness and effective vibration diameter are approximately 500 nm and [...] Read more.
This article presents an extrinsic fiber-optic acoustic sensor applied for partial discharge (PD) detection in air. A Fabry–Perot (F-P) cavity consisting of a single-mode fiber (SMF) and a graphene oxide (GO) film, whose thickness and effective vibration diameter are approximately 500 nm and 4.377 mm, respectively, is used as this sensing core, and the manufacturing process of GO diaphragms and this sensing probe is illustrated to be simple and controllable. Performance tests indicate that this proposed sensor maintains a linear acoustic-pressure response and a flat frequency response in the range of 200 Hz to 20 kHz, while being an omnidirectional sensor and having high working stability during a ten-day test period. Additionally, PD detection results show that the minimum PD size detected by this proposed sensor in air was approximately 100 pC, which demonstrates that this proposed sensor can achieve high-sensitivity PD detection in air. Full article
Show Figures

Figure 1

21 pages, 7147 KB  
Article
Comparison between Linear and Branched Polyethylenimine and Reduced Graphene Oxide Coatings as a Capture Layer for Micro Resonant CO2 Gas Concentration Sensors
by Alberto Prud’homme and Frederic Nabki
Sensors 2020, 20(7), 1824; https://doi.org/10.3390/s20071824 - 25 Mar 2020
Cited by 19 | Viewed by 6413
Abstract
The comparison between potential coatings for the measurement of CO2 concentration through the frequency shift in micro-resonators is presented. The polymers evaluated are linear polyethylenimine, branched polyethylenimine and reduced graphene oxide (rGO) by microwave reduction with polyethylenimine. The characterization of the coatings [...] Read more.
The comparison between potential coatings for the measurement of CO2 concentration through the frequency shift in micro-resonators is presented. The polymers evaluated are linear polyethylenimine, branched polyethylenimine and reduced graphene oxide (rGO) by microwave reduction with polyethylenimine. The characterization of the coatings was made by using 6 MHz gold-plated quartz crystals, and a proof-of-concept sensor is shown with a diaphragm electrostatic microelectromechanical systems (MEMS) resonator. The methods of producing the solutions of the polymers deposited onto the quartz crystals are presented. A CO2 concentration range from 0.05% to 1% was dissolved in air and humidity level were controlled and evaluated. Linear polyethylenimine showed superior performance with a reaction time obtained for stabilization after the concentration increase of 345 s, while the time for recovery was of 126 s, with a maximum frequency deviation of 33.6 Hz for an in-air CO2 concentration of 0.1%. Full article
(This article belongs to the Special Issue Nanomechanical Sensors)
Show Figures

Figure 1

10 pages, 2084 KB  
Article
Improving the High-Frequency Response of PEI-Based Earphone with Sodium Copper Chlorophyllin
by Hao-Zhi Li, Jun-Jie Wu, Wei-Jen Lee and Chien-Sheng Chen
Molecules 2020, 25(1), 219; https://doi.org/10.3390/molecules25010219 - 5 Jan 2020
Cited by 3 | Viewed by 4418
Abstract
The polyetherimide diaphragm, sodium copper chlorophyllin (SCC), and copper ion coating composite used on earphones were observed to improve the high-frequency (10k–14k Hz) performance. This reinforcement phenomenon was expected to make the sound experience brighter and more diverse. By SEM observation, the mixed [...] Read more.
The polyetherimide diaphragm, sodium copper chlorophyllin (SCC), and copper ion coating composite used on earphones were observed to improve the high-frequency (10k–14k Hz) performance. This reinforcement phenomenon was expected to make the sound experience brighter and more diverse. By SEM observation, the mixed coating of SCC/Cu2+ on the polyethylenimine (PEI) diaphragm exhibited a planar blocky structure and was tightly bonded to the surface of the PEI polymer without the aid of colloids. The endothermic process of SCC and metal ion complexation was analyzed by isothermal titration calorimetry. The association ratios of SCC/Cu2+ and SCC/Ni2+ were 4/1 and 6/1, respectively, and the SCC/Cu2+ association yielded a stronger binding constant and more free energy. It was expected that the SCC/Cu2+(4/1) mixed liquid would be immobilized on the PEI polymer by multivalent interaction, including hydrogen-bonding networks between carboxyl groups of SCC and amine groups of PEI, and cross-linking of bridging copper ions. We used dimethylethylenediamine (DME) monomer instead of PEI polymer to analyze this multivalent interaction and observed a two-stage exothermic association of SCC/Cu2+(4/1) and DME with a total Gibbs free energy of 15.15 kcal/mol. We observed that the binding energy could be used to explain that the SCC/Cu2+ mixed formulation could be fixed on the surface of the PEI polymer and could enhance the strength of the PEI film. Compared with graphene films, which can continuously improve the performance of high and ultrasonic frequencies, this study was devoted to and was initiated for the purpose of applying porphyrin compounds to improve music performance. Full article
Show Figures

Graphical abstract

13 pages, 3358 KB  
Article
Opto-thermally Excited Fabry-Perot Resonance Frequency Behaviors of Clamped Circular Graphene Membrane
by Fu-Tao Shi, Shang-Chun Fan, Cheng Li and Zi-Ang Li
Nanomaterials 2019, 9(4), 563; https://doi.org/10.3390/nano9040563 - 7 Apr 2019
Cited by 8 | Viewed by 4096
Abstract
An opto-thermally excited optical fiber Fabry-Perot (F-P) resonant probe with suspended clamped circular graphene diaphragm is presented in this paper. Then, the dependence of resonance frequency behaviors of graphene diaphragm upon opto-mechanical factors including membrane properties, laser excitation parameters and film boundary conditions [...] Read more.
An opto-thermally excited optical fiber Fabry-Perot (F-P) resonant probe with suspended clamped circular graphene diaphragm is presented in this paper. Then, the dependence of resonance frequency behaviors of graphene diaphragm upon opto-mechanical factors including membrane properties, laser excitation parameters and film boundary conditions are investigated via COMSOL Multiphysics simulation. The results show that the radius and thickness of membrane will linearly affect the optical fiber light-induced temperature distribution, thus resulting in rapidly decreasing resonance frequency changes with the radius-to-thickness ratio. Moreover, the prestress can be regulated in the range of 108 Pa to 109 Pa by altering the environmental temperature with a scale factor of 14.2 MPa/K. It is important to note that the availability of F-P resonant probe with a defective clamped circular graphene membrane can be improved notably by fabricating the defected circular membrane to a double-end clamped beam, which gives a broader perspective to characterize the resonance performance of opto-thermally excited F-P resonators. Full article
Show Figures

Figure 1

9 pages, 1709 KB  
Article
Highly Sensitive Tactile Shear Sensor Using Spatially Digitized Contact Electrodes
by Eunsuk Choi, Soonhyung Hwang, Yousang Yoon, Hojun Seo, Jusin Lee, Seongoh Yeom, Gunwoo Ryu, Heewon Yang, Sunjin Kim, Onejae Sul and Seung-Beck Lee
Sensors 2019, 19(6), 1300; https://doi.org/10.3390/s19061300 - 15 Mar 2019
Cited by 17 | Viewed by 6327
Abstract
In this article, we report on a highly sensitive tactile shear sensor that was able to detect minute levels of shear and surface slip. The sensor consists of a suspended elastomer diaphragm with a top ridge structure, a graphene layer underneath, and a [...] Read more.
In this article, we report on a highly sensitive tactile shear sensor that was able to detect minute levels of shear and surface slip. The sensor consists of a suspended elastomer diaphragm with a top ridge structure, a graphene layer underneath, and a bottom substrate with multiple spatially digitized contact electrodes. When shear is applied to the top ridge structure, it creates torque and deflects the elastomer downwards. Then, the graphene electrode makes contact with the bottom spatially digitized electrodes completing a circuit producing output currents depending on the number of electrodes making contact. The tactile shear sensor was able to detect shear forces as small as 6 μN, detect shear direction, and also distinguish surface friction and roughness differences of shearing objects. We also succeeded in detecting the contact slip motion of a single thread demonstrating possible applications in future robotic fingers and remote surgical tools. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

14 pages, 6711 KB  
Article
Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air
by Cheng Li, Tian Lan, Xiyu Yu, Nan Bo, Jingyu Dong and Shangchun Fan
Nanomaterials 2017, 7(11), 366; https://doi.org/10.3390/nano7110366 - 4 Nov 2017
Cited by 17 | Viewed by 5376
Abstract
We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P) interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to [...] Read more.
We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P) interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality (Q) factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10−2 and 105 Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509–542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0–199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 105 kHz3/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials. Full article
(This article belongs to the Special Issue Graphene and Nanotube Based Devices)
Show Figures

Graphical abstract

Back to TopTop