Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (13)

Search Parameters:
Keywords = flow ripple reduction

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
19 pages, 688 KiB  
Article
The Impact of Foreign Direct Investment on Carbon Emissions in Economies Along the Belt and Road
by Linyue Li and Haoran Zhou
Sustainability 2025, 17(13), 5905; https://doi.org/10.3390/su17135905 - 26 Jun 2025
Viewed by 530
Abstract
With China’s emergence as a major global economy, its involvement in tackling climate change and fostering sustainable growth has garnered considerable focus. What impact does global direct investment have on carbon emissions within Belt and Road economies? This study innovatively utilizes a quantile [...] Read more.
With China’s emergence as a major global economy, its involvement in tackling climate change and fostering sustainable growth has garnered considerable focus. What impact does global direct investment have on carbon emissions within Belt and Road economies? This study innovatively utilizes a quantile regression model to analyze the varied impacts of international direct investment across distinct carbon emission quantiles, further delving into the conditional probability distribution of the dependent variable to provide a strong theoretical basis for precise policy-making by relevant departments and integrating time and space delays in examining the effects of carbon reduction strategies within the Belt and Road Initiative. Furthermore, this study aims to concentrate its research efforts on the host nations. Findings from this study indicate that global direct investments could escalate carbon emissions in economies with lower carbon emissions; yet, with the rise in the host nation’s carbon emissions, the ripple effect of international direct investments in green technology becomes increasingly evident. Empirical evidence indicates that global direct investment in Belt and Road economies demonstrates a significant mitigating effect on carbon emissions, thereby amplifying the decarbonization benefits associated with such cross-border capital flows. Full article
Show Figures

Figure 1

22 pages, 2629 KiB  
Article
Optimal Rainwater Harvesting System for a Commercial Building: A Case Study Focusing on Water and Energy Efficiency
by Douglas Alves, Rita Teixeira, José Baptista, Ana Briga-Sá and Cristina Matos
Sustainability 2025, 17(10), 4584; https://doi.org/10.3390/su17104584 - 16 May 2025
Viewed by 548
Abstract
Water stress is a significant issue in many countries, including Portugal, which has seen a 20% reduction in water availability over the last 20 years, with a further 10–25% reduction expected by the end of the century. To address potable water consumption, this [...] Read more.
Water stress is a significant issue in many countries, including Portugal, which has seen a 20% reduction in water availability over the last 20 years, with a further 10–25% reduction expected by the end of the century. To address potable water consumption, this study aims to identify the optimal rainwater harvesting (RWH) system for a commercial building under various non-potable water use scenarios. This research involved qualitative and quantitative methods, utilizing the Rippl method for storage reservoir sizing and ETA 0701 version 11 guidelines. Various scenarios of non-potable water use were considered, including their budgets and economic feasibility. The best scenario was determined through cash flow analysis, considering the initial investment (RWH construction), income (water bill savings), and expenses (energy costs from hydraulic pumps), and evaluating the net present value (NPV), payback period (PB), and internal rate of return (IRR). The energy savings obtained were calculated by sizing a hybrid system with an RWH system and a photovoltaic (PV) system to supply the energy needs of each of the proposed scenarios and the water pump, making the system independent of the electricity grid. The results show that the best scenario resulted in energy savings of 92.11% for a 7-month period of regularization. These results also demonstrate the possibility for reducing potable water consumption in non-essential situations supported by renewable energy systems, thus helping to mitigate water stress while simultaneously reducing dependence on the grid. Full article
Show Figures

Figure 1

23 pages, 14773 KiB  
Article
Reduction in DC-Link Capacitor Current by Phase Shifting Method for a Dual Three-Phase Voltage Source Inverters Dual Permanent Magnet Synchronous Motors System
by Deniz Şahin and Bülent Dağ
World Electr. Veh. J. 2025, 16(1), 39; https://doi.org/10.3390/wevj16010039 - 14 Jan 2025
Viewed by 1224
Abstract
This paper presents a carrier waves phase shifting method to reduce the dc-link capacitor current for a dual three-phase permanent magnet synchronous motor drive system. Dc-link capacitors absorb the ripple current generated at the input due to the harmonics of the pulse width [...] Read more.
This paper presents a carrier waves phase shifting method to reduce the dc-link capacitor current for a dual three-phase permanent magnet synchronous motor drive system. Dc-link capacitors absorb the ripple current generated at the input due to the harmonics of the pulse width modulation (PWM). The size, cost, reliability, and lifetime of the dc-link capacitor are negatively affected by this ripple current flowing through it. The proposed method is especially appropriate for common dc-link capacitors for a dual inverter system driving two PMSMs. In this paper, the input current of each inverter is analyzed using Double Fourier Analysis, and the harmonic components of the dc-link capacitor current are determined. The carrier wave phase shifting method is proposed to reduce the magnitude of the harmonics and thus reduce the dc-link capacitor current. Furthermore, the optimum angle between the carrier waves for the maximum reduction in the dc-link capacitor current is analyzed and simulated for different scenarios considering the speed and load torque of the PMSMs. The proposed method is verified through experiments and PMSMs are driven by three-phase voltage source inverters (VSIs) modulated with Space Vector Pulse Width Modulation (SVPWM), which is the most common PWM strategy. The proposed method reduces the dc-link capacitor current by 60%, thereby significantly decreasing the required dc-link capacitance, the volume of the drive system, and its cost. Full article
Show Figures

Figure 1

23 pages, 24821 KiB  
Article
Flow Ripple Reduction in Reciprocating Pumps by Multi-Phase Rectification
by Gürhan Özkayar, Zhilin Wang, Joost Lötters, Marcel Tichem and Murali Krishna Ghatkesar
Sensors 2023, 23(15), 6967; https://doi.org/10.3390/s23156967 - 5 Aug 2023
Cited by 3 | Viewed by 2618
Abstract
Reciprocating piezoelectric micropumps enable miniaturization in microfluidics for lab-on-a-chip applications such as organs-on-chips (OoC). However, achieving a steady flow when using these micropumps is a significant challenge because of flow ripples in the displaced liquid, especially at low frequencies or low flow rates [...] Read more.
Reciprocating piezoelectric micropumps enable miniaturization in microfluidics for lab-on-a-chip applications such as organs-on-chips (OoC). However, achieving a steady flow when using these micropumps is a significant challenge because of flow ripples in the displaced liquid, especially at low frequencies or low flow rates (<50 µL/min). Although dampers are widely used for reducing ripples in a flow, their efficiency depends on the driving frequency of the pump. Here, we investigated multi-phase rectification as an approach to minimize ripples at low flow rates by connecting piezoelectric micropumps in parallel. The efficiency in ripple reduction was evaluated with an increasing number (n) of pumps connected in parallel, each actuated by an alternating voltage waveform with a phase difference of 2π/n (called multi-phase rectification) at a chosen frequency. We introduce a fluidic ripple factor (RFfl.), which is the ratio of the root mean square (RMS) value of the fluctuations present in the rectified output to the average fluctuation-free value of the discharge flow, as a metric to express the quality of the flow. The fluidic ripple factor was reduced by more than 90% by using three-phase rectification when compared to one-phase rectification in the 2–60 μL/min flow rate range. Analytical equations to estimate the fluidic ripple factor for a chosen number of pumps connected in parallel are presented, and we experimentally confirmed up to four pumps. The analysis shown can be used to design a frequency-independent multi-phase fluid rectifier to the desired ripple level in a flow for reciprocating pumps. Full article
(This article belongs to the Special Issue The Development of Piezoelectric Sensors and Actuators)
Show Figures

Figure 1

20 pages, 1001 KiB  
Article
Assessment of Converter Performance in Hybrid AC-DC Power System under Optimal Power Flow with Minimum Number of DC Link Control Variables
by Chintan Patel, Tanmoy Malakar and S. Sreejith
Energies 2023, 16(15), 5800; https://doi.org/10.3390/en16155800 - 4 Aug 2023
Cited by 3 | Viewed by 1303
Abstract
This paper presents a strategy to evaluate the performances of converter stations under the optimized operating points of hybrid AC-DC power systems with a reduced number of DC link variables. Compared to previous works reported with five DC-side control variables (CVs), the uniqueness [...] Read more.
This paper presents a strategy to evaluate the performances of converter stations under the optimized operating points of hybrid AC-DC power systems with a reduced number of DC link variables. Compared to previous works reported with five DC-side control variables (CVs), the uniqueness of the presented optimal power flow (OPF) formulation lies within the selection of only two DC-side control variables (CVs), such as the inverter voltage and current in the DC link, apart from the conventional AC-side variables. Previous research has mainly been focused on optimizing hybrid power system performance through OPF-based formulations, but has mostly ignored the associated converter performances. Hence, in this study, converter performance, in terms of ripple and harmonics in DC voltage and AC current and the utilization of the converter infrastructure, is evaluated. The minimization of active power loss is taken as an objective function, and the problem is solved for a modified IEEE 30 bus system using a recently developed and very efficient Archimedes optimization algorithm (AOA). Case studies are performed to assess the efficacy of the presented OPF model in power systems, as well as converter performance. Furthermore, the results are extended to assess the applicability of the proposed model to the allocation of photovoltaic (PV)-type distributed generations (DGs) in hybrid AC-DC systems. The average improvement in power loss is found to be around 7.5% compared to the reported results. Furthermore, an approximate 10% improvement in converter power factor and an approximate 50% reduction in ripple factor are achieved. Full article
Show Figures

Figure 1

12 pages, 2972 KiB  
Article
Modelling of an In-Line Bladder-Type Hydraulic Suppressor for Pressure Ripple Reduction in Positive Displacement Pumps
by Paolo Casoli, Carlo Maria Vescovini and Massimo Rundo
Machines 2023, 11(6), 620; https://doi.org/10.3390/machines11060620 - 3 Jun 2023
Cited by 3 | Viewed by 1911
Abstract
Positive displacement pumps are widely employed for their characteristics, but the pulsating flow they produce is a major and well-known drawback. To reduce the flow ripple produced by the pump, which in turn generates a pressure ripple, many methods have been investigated, from [...] Read more.
Positive displacement pumps are widely employed for their characteristics, but the pulsating flow they produce is a major and well-known drawback. To reduce the flow ripple produced by the pump, which in turn generates a pressure ripple, many methods have been investigated, from optimising the pump geometrical features to the introduction of active and passive systems to the delivery side. A passive system that has demonstrated to be particularly effective is the in-line bladder-type hydraulic pulsation suppressor. This device, consisting of a bladder gas-charged accumulator with a singular geometry, has been the subject of several studies. This paper describes a model based on the lumped parameter method for simulating and predicting the reduction effect on the pressure ripple achieved by the hydraulic suppressor. To validate the model, an experimental study was conducted, which confirmed the good potential of the model proposed thanks to the good agreement between the modelling results and empirical data. Full article
(This article belongs to the Special Issue Components of Hydrostatic Drive Systems)
Show Figures

Figure 1

20 pages, 6895 KiB  
Article
A Single-Phase Compact-Sized Matrix Converter with Symmetrical Bipolar Buck and Boost Output Voltage Control
by Naveed Ashraf, Ghulam Abbas, Ali Raza, Nasim Ullah, Alsharef Mohammad and Mohamed Emad Farrag
Energies 2022, 15(20), 7534; https://doi.org/10.3390/en15207534 - 12 Oct 2022
Cited by 2 | Viewed by 2027
Abstract
The development of single-phase symmetrical bipolar voltage gain matrix converters (MC) is growing rapidly as they find their application in power systems for dynamic restoration of line voltages, high voltage AC–DC converters, and variable frequency controllers for many industrial processes. However, the existing [...] Read more.
The development of single-phase symmetrical bipolar voltage gain matrix converters (MC) is growing rapidly as they find their application in power systems for dynamic restoration of line voltages, high voltage AC–DC converters, and variable frequency controllers for many industrial processes. However, the existing trend in matrix converter technology is a buck–boost operation that has inherently serious issues of high voltage and current surges or stresses. This is a big source of the high voltage and current rating of semiconductor switching devices. There is also a problem of high ripples both for voltage as well for current, requiring large size of filtering capacitors and inductors. The non-symmetrical control of the voltage gain increases the control complication. A large count of operating transistors is critical regarding their cost, size, and power conversion losses, as the space and cost required by their gate control circuits are much larger than the size and cost of the switching transistors. Thus, in this research work, a new single-phase MC is introduced only employing six fully controlled switching devices, ensuring similar operation or outputs as is obtained from the existing topologies that require the use of eight or more fully controlled switching devices, and the reduction by two or more switching transistors helps to compact the overall size and lower the overall cost. The separation in its voltage buck and boost operation enables smooth control of the voltage gain through duty cycle control. The low values of the voltage and current surges reduce the power rating and losses of the switching devices. The flow of the current in the filtering inductor is kept unidirectional to avoid the current interruption and reversal problem once the operation of the converter is abruptly switched from inverting to non-inverting and vice versa. All these factors are comprehensively detailed through the circuit’s description and comparative analysis. Simulation and practical results are presented to confirm the effectiveness of the developed circuit topology. Full article
Show Figures

Figure 1

22 pages, 7877 KiB  
Article
Theoretical Analysis of Active Flow Ripple Control in Positive Displacement Pumps
by Paolo Casoli, Carlo Maria Vescovini, Fabio Scolari and Massimo Rundo
Energies 2022, 15(13), 4703; https://doi.org/10.3390/en15134703 - 27 Jun 2022
Cited by 7 | Viewed by 2081
Abstract
Positive displacement machines present a well-known major drawback that is the oscillation in delivered flow rate. This paper presents two active solutions for reducing the flow ripple generated by a pump with an external device actuated by means of a piezo-stack actuator. The [...] Read more.
Positive displacement machines present a well-known major drawback that is the oscillation in delivered flow rate. This paper presents two active solutions for reducing the flow ripple generated by a pump with an external device actuated by means of a piezo-stack actuator. The work is focused on a theoretical analysis, with the aim of collecting information about the performance of the solutions proposed and their main advantages and drawbacks. The active methods proposed involve a cylindrical actuator connected to the delivery line of the pump. The piston could be actuated directly by a piezo-stack actuator or by a differential pressure modulated by a proportional piezo actuated valve. The actuators were modelled and a control algorithm based on Least Mean Square algorithm was used to achieve the adaptability for both systems at different operating conditions. The developed mathematical model permits to define the great potential of these solutions that can drastically reduce the flow ripple. The first architecture presented resulted as the best solution, while the second one allowed reduction of the production cost. Full article
(This article belongs to the Special Issue Application and Analysis in Fluid Power Systems)
Show Figures

Figure 1

18 pages, 7259 KiB  
Article
Control Method of Four Wire Active Power Filter Based on Three-Phase Neutral Point Clamped T-Type Converter
by Dawid Buła, Grzegorz Jarek, Jarosław Michalak and Marcin Zygmanowski
Energies 2021, 14(24), 8427; https://doi.org/10.3390/en14248427 - 14 Dec 2021
Cited by 11 | Viewed by 2822
Abstract
An active power filter based on a three-level neutral point clamped T-type converter with LCL input filter is presented in the paper. The main goal of the paper is the analysis of a control system that ensures independent control of a current in [...] Read more.
An active power filter based on a three-level neutral point clamped T-type converter with LCL input filter is presented in the paper. The main goal of the paper is the analysis of a control system that ensures independent control of a current in each phase. The presented control method of the filter allows reactive power compensation and/or a higher harmonics reduction to be achieved in each phase independently, with the possibility of control tan (φ) coefficient. This allows the power flow between the phases to be minimalized and reduces the RMS values of filter currents without the need to balance grid currents. The analysis presents the possibility of an operation in different modes, which was verified by experimental results. The results have been obtained in a 20 ARMS laboratory system described in the paper. The results reveal relatively low power losses, which are a feature of the selected three-level T-type topology. Additionally, that topology, when compared to a two-level one, ensures the reduction in current ripples with the same parameters of passive components. Full article
(This article belongs to the Special Issue Control Strategies Applied to Active Power Filters)
Show Figures

Figure 1

22 pages, 8450 KiB  
Article
A Numerical Analysis of an Innovative Flow Ripple Reduction Method for External Gear Pumps
by Gianluca Marinaro, Emma Frosina and Adolfo Senatore
Energies 2021, 14(2), 471; https://doi.org/10.3390/en14020471 - 17 Jan 2021
Cited by 33 | Viewed by 4146
Abstract
In this paper, an innovative solution to minimize noise emission, acting on the flow ripple, in a prototype External Gear Pump (EGP) is presented. Firstly, a new tool capable to completely simulate this pump’s typologies, called EgeMATor, is presented; the hydraulic model, adopted [...] Read more.
In this paper, an innovative solution to minimize noise emission, acting on the flow ripple, in a prototype External Gear Pump (EGP) is presented. Firstly, a new tool capable to completely simulate this pump’s typologies, called EgeMATor, is presented; the hydraulic model, adopted for the simulation, is based on a lumped parameter method using a control volume approach. Starting from the pump drawing, thanks to different subroutines developed in different environments interconnected, it is possible to analyze an EGP. Results have been compared with the outputs of a three-dimensional CFD numerical model built up using a commercial code, already used with success by the authors. In the second section, an innovative solution to reduce the flow ripple is implemented. This technology is called Alternative Capacitive Volumes (ACV) and works by controlling and uniformizing the reverse flow, performing a consistent reduction of flow non-uniformity amplitude. In particular, a high reduction of the flow non-uniformity is notable in the frequency domain on the second fundamental frequency. The technology is easy to accommodate in a pump housing, especially for high-pressure components, and it helps with reducing the fluid-borne noise. Full article
(This article belongs to the Special Issue Gear Pumps and Motors)
Show Figures

Figure 1

15 pages, 5112 KiB  
Article
Flow Ripple Reduction of Axial-Piston Pump by Structure Optimizing of Outlet Triangular Damping Groove
by Haocen Hong, Chunxiao Zhao, Bin Zhang, Dapeng Bai and Huayong Yang
Processes 2020, 8(12), 1664; https://doi.org/10.3390/pr8121664 - 17 Dec 2020
Cited by 28 | Viewed by 4662
Abstract
The triangular damping groove on the valve plate can effectively reduce the discharge flow ripple of an axial piston pump, which structural parameters will directly affect the pump’s dynamic characteristics. Herein, a multi-parameter data-based structure optimizing method of the triangular damping groove is [...] Read more.
The triangular damping groove on the valve plate can effectively reduce the discharge flow ripple of an axial piston pump, which structural parameters will directly affect the pump’s dynamic characteristics. Herein, a multi-parameter data-based structure optimizing method of the triangular damping groove is investigated using numerical models and simulation results. The mathematical models of a nine-piston pump are proposed and developed by MATLAB/Simulink, and the simulation results are verified by experimental results. Then, the effects of width angle and depth angle on discharge flow are analyzed. Based on the analysis of groove parameters, an optimizing index, which considering the time domain characteristics of discharge flow, is proposed. As results show, comparing with the initial specific groove structure, the amplitude of flow ripple is reduced from 14.6% to 9.8% with the optimized structure. The results demonstrate that the outlet flow ripple can be significantly reduced by the optimized structure, and the proposed multi-parameter optimizing method can play a guiding significance in the design of low-ripple axial piston pumps. Full article
Show Figures

Figure 1

20 pages, 4237 KiB  
Article
A Tandem Axial-Piston Unit Based Strategy for the Reduction of Noise Sources in Hydraulic Systems
by Leandro Danes and Andrea Vacca
Energies 2020, 13(20), 5377; https://doi.org/10.3390/en13205377 - 15 Oct 2020
Cited by 5 | Viewed by 2681
Abstract
This article presents a novel passive fluid borne noise source reduction strategy, based on tandem axial-piston unit indexing with the usage of symmetric lines. The strategy consists of setting the phase between the two synchronous units to accomplish destructive interference in targeted unit [...] Read more.
This article presents a novel passive fluid borne noise source reduction strategy, based on tandem axial-piston unit indexing with the usage of symmetric lines. The strategy consists of setting the phase between the two synchronous units to accomplish destructive interference in targeted unit harmonics. A strategy capable of achieving destructive interference in all odd harmonics is investigated first analytically and then confirmed by a simulation study. Experiments on the proposed strategy confirmed its effectiveness at the first and third pump fundamental harmonics, and pressure ripple reduction was accomplished. The fluid borne noise source reduction in the first and third harmonic is verified to be propagated to pipe vibration and sound power. Regarding the first harmonic, pressure ripple was reduced by up to 18 dB; while for third harmonic, pressure ripple was reduced by up to 11 dB. In the experiment, however, noise cancellation is not achieved for the higher odd harmonics, as is instead found in the simulation. Conversely, transfer functions form pressure ripple to pipe wall acceleration are obtained experimentally, and a critical vibration band from 2000 Hz to 3000 Hz is identified as being crucial for effective overall sound power reduction. Full article
Show Figures

Figure 1

18 pages, 9753 KiB  
Article
Active Pressure Ripple Control in Axial Piston Pumps through High-Frequency Swash Plate Oscillations—A Theoretical Analysis
by Paolo Casoli, Mirko Pastori, Fabio Scolari and Massimo Rundo
Energies 2019, 12(7), 1377; https://doi.org/10.3390/en12071377 - 10 Apr 2019
Cited by 29 | Viewed by 5681
Abstract
Pressure ripple has always been a major drawback in hydraulic circuits, since it is the main source of the overall noise emitted by the pump. This article presents a theoretical analysis on the active control of the pressure ripple in an axial piston [...] Read more.
Pressure ripple has always been a major drawback in hydraulic circuits, since it is the main source of the overall noise emitted by the pump. This article presents a theoretical analysis on the active control of the pressure ripple in an axial piston pump by properly moving the swash plate. The reduction of the pressure oscillations is studied in an active way and for this purpose a mathematical model of the whole pump has been developed, focusing on both the fluid dynamic aspects and the component dynamics. An experimental activity has been performed in order to validate the pump mathematical model. The results of the simulation, compared with the experimental data, highlight a suitable capability of the model to predict both the dynamics of the swash plate and the delivery pressure ripple. The validated model has been used for implementing an active control of the pressure ripple with the aim of properly modifying the machine displacement at high frequency in order to vary the instantaneous delivery flow rate and, consequently, the outlet pressure. The control strategy is grounded on moving the swash plate for modifying the motion law of the pistons through a servo valve integrated into the displacement control system. The simulations results have demonstrated that acting on the pump displacement control is possible to considerably reduce the amplitude of the pressure oscillations. Full article
(This article belongs to the Special Issue Energy Efficiency and Controllability of Fluid Power Systems 2018)
Show Figures

Figure 1

Back to TopTop