Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (86)

Search Parameters:
Keywords = finger-vein

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 4399 KiB  
Article
Deep Learning-Based Fingerprint–Vein Biometric Fusion: A Systematic Review with Empirical Evaluation
by Sarah Almuwayziri, Abeer Al-Nafjan, Hessah Aljumah and Mashael Aldayel
Appl. Sci. 2025, 15(15), 8502; https://doi.org/10.3390/app15158502 - 31 Jul 2025
Viewed by 128
Abstract
User authentication is crucial for safeguarding access to digital systems and services. Biometric authentication serves as a strong and user-friendly alternative to conventional security methods such as passwords and PINs, which are often susceptible to breaches. This study proposes a deep learning-based multimodal [...] Read more.
User authentication is crucial for safeguarding access to digital systems and services. Biometric authentication serves as a strong and user-friendly alternative to conventional security methods such as passwords and PINs, which are often susceptible to breaches. This study proposes a deep learning-based multimodal biometric system that combines fingerprint (FP) and finger vein (FV) modalities to improve accuracy and security. The system explores three fusion strategies: feature-level fusion (combining feature vectors from each modality), score-level fusion (integrating prediction scores from each modality), and a hybrid approach that leverages both feature and score information. The implementation involved five pretrained convolutional neural network (CNN) models: two unimodal (FP-only and FV-only) and three multimodal models corresponding to each fusion strategy. The models were assessed using the NUPT-FPV dataset, which consists of 33,600 images collected from 140 subjects with a dual-mode acquisition device in varied environmental conditions. The results indicate that the hybrid-level fusion with a dominant score weight (0.7 score, 0.3 feature) achieved the highest accuracy (99.79%) and the lowest equal error rate (EER = 0.0018), demonstrating superior robustness. Overall, the results demonstrate that integrating deep learning with multimodal fusion is highly effective for advancing scalable and accurate biometric authentication solutions suitable for real-world deployments. Full article
Show Figures

Figure 1

15 pages, 9198 KiB  
Article
Microwave Antenna Sensing for Glucose Monitoring in a Vein Model Mimicking Human Physiology
by Youness Zaarour, Fatimazahrae El Arroud, Tomas Fernandez, Juan Luis Cano, Rafiq El Alami, Otman El Mrabet, Abdelouheb Benani, Abdessamad Faik and Hafid Griguer
Biosensors 2025, 15(5), 282; https://doi.org/10.3390/bios15050282 - 30 Apr 2025
Viewed by 1030
Abstract
Non-invasive glucose monitoring has become a critical area of research for diabetes management, offering a less intrusive and more patient-friendly alternative to traditional methods such as finger-prick tests. This study presents a novel approach using a semi-solid tissue-mimicking phantom designed to replicate the [...] Read more.
Non-invasive glucose monitoring has become a critical area of research for diabetes management, offering a less intrusive and more patient-friendly alternative to traditional methods such as finger-prick tests. This study presents a novel approach using a semi-solid tissue-mimicking phantom designed to replicate the dielectric properties of human skin and blood vessels. The phantom was simplified to focus solely on the skin layer, with embedded channels representing veins to achieve realistic glucose monitoring conditions. These channels were filled with D-(+)-Glucose solutions at varying concentrations (60 mg/dL to 200 mg/dL) to simulate physiological changes in blood glucose levels. A miniature patch antenna optimized to operate at 14 GHz with a penetration depth of approximately 1.5 mm was designed and fabricated. The antenna was tested in direct contact with the skin phantom, allowing for precise measurements of the changes in glucose concentration without interference from deeper tissue layers. Simulations and experiments demonstrated the antenna’s sensitivity to variations in glucose concentration, as evidenced by measurable shifts in the dielectric properties of the phantom. Importantly, the system enabled stationary measurements by injecting glucose solutions into the same blood vessels, eliminating the need to reposition the sensor while ensuring reliable and repeatable results. This work highlights the importance of shallow penetration depth in targeting close vessels for noninvasive glucose monitoring, and emphasizes the potential of microwave-based sensing systems as a practical solution for continuous glucose management. Full article
(This article belongs to the Section Biosensors and Healthcare)
Show Figures

Figure 1

28 pages, 1737 KiB  
Article
Finger Vein Recognition Based on Unsupervised Spiking Convolutional Neural Network with Adaptive Firing Threshold
by Li Yang, Qiong Yao and Xiang Xu
Sensors 2025, 25(7), 2279; https://doi.org/10.3390/s25072279 - 3 Apr 2025
Viewed by 485
Abstract
Currently, finger vein recognition (FVR) stands as a pioneering biometric technology, with convolutional neural networks (CNNs) and Transformers, among other advanced deep neural networks (DNNs), consistently pushing the boundaries of recognition accuracy. Nevertheless, these DNNs are inherently characterized by static, continuous-valued neuron activations, [...] Read more.
Currently, finger vein recognition (FVR) stands as a pioneering biometric technology, with convolutional neural networks (CNNs) and Transformers, among other advanced deep neural networks (DNNs), consistently pushing the boundaries of recognition accuracy. Nevertheless, these DNNs are inherently characterized by static, continuous-valued neuron activations, necessitating intricate network architectures and extensive parameter training to enhance performance. To address these challenges, we introduce an adaptive firing threshold-based spiking neural network (ATSNN) for FVR. ATSNN leverages discrete spike encodings to transforms static finger vein images into spike trains with spatio-temporal dynamic features. Initially, Gabor and difference of Gaussian (DoG) filters are employed to convert image pixel intensities into spike latency encodings. Subsequently, these spike encodings are fed into the ATSNN, where spiking features are extracted using biologically plausible local learning rules. Our proposed ATSNN dynamically adjusts the firing thresholds of neurons based on average potential tensors, thereby enabling adaptive modulation of the neuronal input-output response and enhancing network robustness. Ultimately, the spiking features with the earliest emission times are retained and utilized for classifier training via a support vector machine (SVM). Extensive experiments conducted across three benchmark finger vein datasets reveal that our ATSNN model not only achieves remarkable recognition accuracy but also excels in terms of reduced parameter count and model complexity, surpassing several existing FVR methods. Furthermore, the sparse and event-driven nature of our ATSNN renders it more biologically plausible compared to traditional DNNs. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

21 pages, 2711 KiB  
Article
HUnet++: An Efficient Method for Vein Mask Extraction Based on Hierarchical Feature Fusion
by Peng Liu, Yujiao Jia and Xiaofan Cao
Symmetry 2025, 17(3), 420; https://doi.org/10.3390/sym17030420 - 11 Mar 2025
Viewed by 572
Abstract
With the development of biometric recognition technology, the technology of vein-based verification has garnered growing interest within the domain of biometric recognition. Nonetheless, the difficulties in differentiating between the background and the vein patterns, as well as the multi-branching, irregularity, and high-precision requirements [...] Read more.
With the development of biometric recognition technology, the technology of vein-based verification has garnered growing interest within the domain of biometric recognition. Nonetheless, the difficulties in differentiating between the background and the vein patterns, as well as the multi-branching, irregularity, and high-precision requirements of the vein structure, often make it difficult to achieve high precision and speed in vein mask extraction. To address this problem, we propose HUnet++, a novel vein recognition method based on the symmetric network structure of the Unet++ model, which enhances the speed of vein mask extraction while maintaining accuracy. The HUnet++ model consists of two main parts: a Feature Capture (FC) module for hierarchical feature extraction, and a Feature Fusion (FF) module for multi-scale feature integration. This structural design bears a striking resemblance to the symmetrical architecture of the Unet++ model, playing a crucial role in ensuring the balance between feature processing and integration. Experimental results show that the proposed method achieves precision rates of 91.4%, 84.1%, 78.07%, and 89.5% on the manually labeled dataset and traditionally labeled datasets (SDUMLA-HMT, FV-USM, Custom dataset), respectively. For a single image with a size of 240 pixels, the feature extraction time is 0.0131 s, which is nearly twice as fast as the original model. Full article
(This article belongs to the Section Computer)
Show Figures

Figure 1

17 pages, 1614 KiB  
Article
A High-Speed Finger Vein Recognition Network with Multi-Scale Convolutional Attention
by Ziyun Zhang, Peng Liu, Chen Su and Shoufeng Tong
Appl. Sci. 2025, 15(5), 2698; https://doi.org/10.3390/app15052698 - 3 Mar 2025
Viewed by 1082
Abstract
With the advancement of technology, biometric recognition technology has gained widespread attention in identity authentication due to its high security and convenience. Finger vein recognition, as a biometric technology, utilizes near-infrared imaging to extract subcutaneous vein patterns, offering high security, stability, and anti-spoofing [...] Read more.
With the advancement of technology, biometric recognition technology has gained widespread attention in identity authentication due to its high security and convenience. Finger vein recognition, as a biometric technology, utilizes near-infrared imaging to extract subcutaneous vein patterns, offering high security, stability, and anti-spoofing capabilities. Existing research primarily focuses on improving recognition accuracy; however, this often comes at the cost of increased model complexity, which, in turn, affects recognition efficiency, making it difficult to balance accuracy and speed in practical applications. To address this issue, this paper proposes a high-accuracy and high-efficiency finger vein recognition model called Faster Multi-Scale Finger Vein Recognition Network (FMFVNet), which optimizes recognition speed through the FasterNet Block module while ensuring recognition accuracy with the Multi-Scale Convolutional Attention (MSCA) module. Experimental results show that on the FV-USM and SDUMLA-HMT datasets, FMFVNet achieves recognition accuracies of 99.80% and 99.06%, respectively. Furthermore, the model’s inference time is reduced to 1.75 ms, representing a 20.8% improvement over the fastest baseline model and a 62.7% improvement over the slowest, achieving more efficient finger vein recognition. Full article
(This article belongs to the Section Computing and Artificial Intelligence)
Show Figures

Figure 1

30 pages, 7517 KiB  
Article
MixCFormer: A CNN–Transformer Hybrid with Mixup Augmentation for Enhanced Finger Vein Attack Detection
by Zhaodi Wang, Shuqiang Yang, Huafeng Qin, Yike Liu and Junqiang Wang
Electronics 2025, 14(2), 362; https://doi.org/10.3390/electronics14020362 - 17 Jan 2025
Cited by 2 | Viewed by 1261
Abstract
Finger vein recognition has gained significant attention for its importance in enhancing security, safeguarding privacy, and ensuring reliable liveness detection. As a foundation of vein recognition systems, vein detection faces challenges, including low feature extraction efficiency, limited robustness, and a heavy reliance on [...] Read more.
Finger vein recognition has gained significant attention for its importance in enhancing security, safeguarding privacy, and ensuring reliable liveness detection. As a foundation of vein recognition systems, vein detection faces challenges, including low feature extraction efficiency, limited robustness, and a heavy reliance on real-world data. Additionally, environmental variability and advancements in spoofing technologies further exacerbate data privacy and security concerns. To address these challenges, this paper proposes MixCFormer, a hybrid CNN–transformer architecture that incorporates Mixup data augmentation to improve the accuracy of finger vein liveness detection and reduce dependency on large-scale real datasets. First, the MixCFormer model applies baseline drift elimination, morphological filtering, and Butterworth filtering techniques to minimize the impact of background noise and illumination variations, thereby enhancing the clarity and recognizability of vein features. Next, finger vein video data are transformed into feature sequences, optimizing feature extraction and matching efficiency, effectively capturing dynamic time-series information and improving discrimination between live and forged samples. Furthermore, Mixup data augmentation is used to expand sample diversity and decrease dependency on extensive real datasets, thereby enhancing the model’s ability to recognize forged samples across diverse attack scenarios. Finally, the CNN and transformer architecture leverages both local and global feature extraction capabilities to capture vein feature correlations and dependencies. Residual connections improve feature propagation, enhancing the stability of feature representations in liveness detection. Rigorous experimental evaluations demonstrate that MixCFormer achieves a detection accuracy of 99.51% on finger vein datasets, significantly outperforming existing methods. Full article
Show Figures

Figure 1

18 pages, 6611 KiB  
Article
The Impact of Bevacizumab and miR200c on EMT and EGFR-TKI Resistance in EGFR-Mutant Lung Cancer Organoids
by Nobuaki Kobayashi, Seigo Katakura, Nobuhiko Fukuda, Kohei Somekawa, Ayami Kaneko and Takeshi Kaneko
Genes 2024, 15(12), 1624; https://doi.org/10.3390/genes15121624 - 19 Dec 2024
Cited by 1 | Viewed by 1509
Abstract
Objectives: This research aims to investigate the mechanisms of resistance to epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) in non-small-cell lung cancer (NSCLC), particularly focusing on the role of the epithelial–mesenchymal transition (EMT) within the tumor microenvironment (TME). Materials and Methods [...] Read more.
Objectives: This research aims to investigate the mechanisms of resistance to epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) in non-small-cell lung cancer (NSCLC), particularly focusing on the role of the epithelial–mesenchymal transition (EMT) within the tumor microenvironment (TME). Materials and Methods: We employed an in vitro three-dimensional organoid model that mirrors the physiology of human lung cancer. These organoids consist of lung cancer cells harboring specific EGFR mutations, human mesenchymal stem cells, and human umbilical vein endothelial cells. We analyzed EMT and drug resistance markers, and evaluated the effects of the anti-angiogenic agent Bevacizumab and micro-RNA miR200c. Results: The study identified a significant link between EMT and EGFR-TKI resistance. Notable findings included a decrease in E-cadherin and an increase in Zinc Finger E-Box Binding Homeobox 1 (ZEB1), both of which influenced EMT and resistance to treatment. Bevacizumab showed promise in improving drug resistance and mitigating EMT, suggesting an involvement of the Vascular Endothelial Growth Factor (VEGF) cascade. Transfection with miR200c was associated with improved EMT and drug resistance, further highlighting the role of EMT in TKI resistance. Conclusions: Our research provides significant insights into the EMT-driven EGFR-TKI resistance in NSCLC and offers potential strategies to overcome resistance, including the use of Bevacizumab and miR200c. However, due to the limitations in organoid models in replicating precise human cancer TME and the potential influence of specific EGFR mutations, further in vivo studies and clinical trials are necessary for validation. Full article
(This article belongs to the Section Human Genomics and Genetic Diseases)
Show Figures

Figure 1

32 pages, 8354 KiB  
Article
Estimation of Fractal Dimension and Detection of Fake Finger-Vein Images for Finger-Vein Recognition
by Seung Gu Kim, Jin Seong Hong, Jung Soo Kim and Kang Ryoung Park
Fractal Fract. 2024, 8(11), 646; https://doi.org/10.3390/fractalfract8110646 - 31 Oct 2024
Cited by 3 | Viewed by 1447
Abstract
With recent advancements in deep learning, spoofing techniques have developed and generative adversarial networks (GANs) have become an emerging threat to finger-vein recognition systems. Therefore, previous research has been performed to generate finger-vein images for training spoof detectors. However, these are limited and [...] Read more.
With recent advancements in deep learning, spoofing techniques have developed and generative adversarial networks (GANs) have become an emerging threat to finger-vein recognition systems. Therefore, previous research has been performed to generate finger-vein images for training spoof detectors. However, these are limited and researchers still cannot generate elaborate fake finger-vein images. Therefore, we develop a new densely updated contrastive learning-based self-attention generative adversarial network (DCS-GAN) to create elaborate fake finger-vein images, enabling the training of corresponding spoof detectors. Additionally, we propose an enhanced convolutional network for a next-dimension (ConvNeXt)-Small model with a large kernel attention module as a new spoof detector capable of distinguishing the generated fake finger-vein images. To improve the spoof detection performance of the proposed method, we introduce fractal dimension estimation to analyze the complexity and irregularity of class activation maps from real and fake finger-vein images, enabling the generation of more realistic and sophisticated fake finger-vein images. Experimental results obtained using two open databases showed that the fake images by the DCS-GAN exhibited Frechet inception distances (FID) of 7.601 and 23.351, with Wasserstein distances (WD) of 18.158 and 10.123, respectively, confirming the possibility of spoof attacks when using existing state-of-the-art (SOTA) frameworks of spoof detection. Furthermore, experiments conducted with the proposed spoof detector yielded average classification error rates of 0.4% and 0.12% on the two aforementioned open databases, respectively, outperforming existing SOTA methods for spoof detection. Full article
Show Figures

Figure 1

23 pages, 9520 KiB  
Article
Visual Feature-Guided Diamond Convolutional Network for Finger Vein Recognition
by Qiong Yao, Dan Song, Xiang Xu and Kun Zou
Sensors 2024, 24(18), 6097; https://doi.org/10.3390/s24186097 - 20 Sep 2024
Cited by 2 | Viewed by 977
Abstract
Finger vein (FV) biometrics have garnered considerable attention due to their inherent non-contact nature and high security, exhibiting tremendous potential in identity authentication and beyond. Nevertheless, challenges pertaining to the scarcity of training data and inconsistent image quality continue to impede the effectiveness [...] Read more.
Finger vein (FV) biometrics have garnered considerable attention due to their inherent non-contact nature and high security, exhibiting tremendous potential in identity authentication and beyond. Nevertheless, challenges pertaining to the scarcity of training data and inconsistent image quality continue to impede the effectiveness of finger vein recognition (FVR) systems. To tackle these challenges, we introduce the visual feature-guided diamond convolutional network (dubbed ‘VF-DCN’), a uniquely configured multi-scale and multi-orientation convolutional neural network. The VF-DCN showcases three pivotal innovations: Firstly, it meticulously tunes the convolutional kernels through multi-scale Log-Gabor filters. Secondly, it implements a distinctive diamond-shaped convolutional kernel architecture inspired by human visual perception. This design intelligently allocates more orientational filters to medium scales, which inherently carry richer information. In contrast, at extreme scales, the use of orientational filters is minimized to simulate the natural blurring of objects at extreme focal lengths. Thirdly, the network boasts a deliberate three-layer configuration and fully unsupervised training process, prioritizing simplicity and optimal performance. Extensive experiments are conducted on four FV databases, including MMCBNU_6000, FV_USM, HKPU, and ZSC_FV. The experimental results reveal that VF-DCN achieves remarkable improvement with equal error rates (EERs) of 0.17%, 0.19%, 2.11%, and 0.65%, respectively, and Accuracy Rates (ACC) of 100%, 99.97%, 98.92%, and 99.36%, respectively. These results indicate that, compared with some existing FVR approaches, the proposed VF-DCN not only achieves notable recognition accuracy but also shows fewer number of parameters and lower model complexity. Moreover, VF-DCN exhibits superior robustness across diverse FV databases. Full article
(This article belongs to the Section Sensing and Imaging)
Show Figures

Figure 1

24 pages, 4262 KiB  
Article
DDP-FedFV: A Dual-Decoupling Personalized Federated Learning Framework for Finger Vein Recognition
by Zijie Guo, Jian Guo, Yanan Huang, Yibo Zhang and Hengyi Ren
Sensors 2024, 24(15), 4779; https://doi.org/10.3390/s24154779 - 23 Jul 2024
Cited by 1 | Viewed by 1508
Abstract
Finger vein recognition methods, as emerging biometric technologies, have attracted increasing attention in identity verification due to their high accuracy and live detection capabilities. However, as privacy protection awareness increases, traditional centralized finger vein recognition algorithms face privacy and security issues. Federated learning, [...] Read more.
Finger vein recognition methods, as emerging biometric technologies, have attracted increasing attention in identity verification due to their high accuracy and live detection capabilities. However, as privacy protection awareness increases, traditional centralized finger vein recognition algorithms face privacy and security issues. Federated learning, a distributed training method that protects data privacy without sharing data across endpoints, is gradually being promoted and applied. Nevertheless, its performance is severely limited by heterogeneity among datasets. To address these issues, this paper proposes a dual-decoupling personalized federated learning framework for finger vein recognition (DDP-FedFV). The DDP-FedFV method combines generalization and personalization. In the first stage, the DDP-FedFV method implements a dual-decoupling mechanism involving model and feature decoupling to optimize feature representations and enhance the generalizability of the global model. In the second stage, the DDP-FedFV method implements a personalized weight aggregation method, federated personalization weight ratio reduction (FedPWRR), to optimize the parameter aggregation process based on data distribution information, thereby enhancing the personalization of the client models. To evaluate the performance of the DDP-FedFV method, theoretical analyses and experiments were conducted based on six public finger vein datasets. The experimental results indicate that the proposed algorithm outperforms centralized training models without increasing communication costs or privacy leakage risks. Full article
(This article belongs to the Special Issue Biometrics Recognition Systems)
Show Figures

Figure 1

23 pages, 2355 KiB  
Article
Two-Layered Multi-Factor Authentication Using Decentralized Blockchain in an IoT Environment
by Saeed Bamashmos, Naveen Chilamkurti and Ahmad Salehi Shahraki
Sensors 2024, 24(11), 3575; https://doi.org/10.3390/s24113575 - 1 Jun 2024
Cited by 5 | Viewed by 2368
Abstract
Internet of Things (IoT) technology is evolving over the peak of smart infrastructure with the participation of IoT devices in a wide range of applications. Traditional IoT authentication methods are vulnerable to threats due to wireless data transmission. However, IoT devices are resource- [...] Read more.
Internet of Things (IoT) technology is evolving over the peak of smart infrastructure with the participation of IoT devices in a wide range of applications. Traditional IoT authentication methods are vulnerable to threats due to wireless data transmission. However, IoT devices are resource- and energy-constrained, so building lightweight security that provides stronger authentication is essential. This paper proposes a novel, two-layered multi-factor authentication (2L-MFA) framework using blockchain to enhance IoT devices and user security. The first level of authentication is for IoT devices, one that considers secret keys, geographical location, and physically unclonable function (PUF). Proof-of-authentication (PoAh) and elliptic curve Diffie–Hellman are followed for lightweight and low latency support. Second-level authentication for IoT users, which are sub-categorized into four levels, each defined by specific factors such as identity, password, and biometrics. The first level involves a matrix-based password; the second level utilizes the elliptic curve digital signature algorithm (ECDSA); and levels 3 and 4 are secured with iris and finger vein, providing comprehensive and robust authentication. We deployed fuzzy logic to validate the authentication and make the system more robust. The 2L-MFA model significantly improves performance, reducing registration, login, and authentication times by up to 25%, 50%, and 25%, respectively, facilitating quicker cloud access post-authentication and enhancing overall efficiency. Full article
(This article belongs to the Section Internet of Things)
Show Figures

Figure 1

14 pages, 2920 KiB  
Article
Zero-FVeinNet: Optimizing Finger Vein Recognition with Shallow CNNs and Zero-Shuffle Attention for Low-Computational Devices
by Nghi C. Tran, Bach-Tung Pham, Vivian Ching-Mei Chu, Kuo-Chen Li, Phuong Thi Le, Shih-Lun Chen, Aufaclav Zatu Kusuma Frisky, Yung-Hui Li and Jia-Ching Wang
Electronics 2024, 13(9), 1751; https://doi.org/10.3390/electronics13091751 - 1 May 2024
Viewed by 1933
Abstract
In the context of increasing reliance on mobile devices, robust personal security solutions are critical. This paper presents Zero-FVeinNet, an innovative, lightweight convolutional neural network (CNN) tailored for finger vein recognition on mobile and embedded devices, which are typically resource-constrained. The model integrates [...] Read more.
In the context of increasing reliance on mobile devices, robust personal security solutions are critical. This paper presents Zero-FVeinNet, an innovative, lightweight convolutional neural network (CNN) tailored for finger vein recognition on mobile and embedded devices, which are typically resource-constrained. The model integrates cutting-edge features such as Zero-Shuffle Coordinate Attention and a blur pool layer, enhancing architectural efficiency and recognition accuracy under various imaging conditions. A notable reduction in computational demands is achieved through an optimized design involving only 0.3 M parameters, thereby enabling faster processing and reduced energy consumption, which is essential for mobile applications. An empirical evaluation on several leading public finger vein datasets demonstrates that Zero-FVeinNet not only outperforms traditional biometric systems in speed and efficiency but also establishes new standards in biometric identity verification. The Zero-FVeinNet achieves a Correct Identification Rate (CIR) of 99.9% on the FV-USM dataset, with a similarly high accuracy on other datasets. This paper underscores the potential of Zero-FVeinNet to significantly enhance security features on mobile devices by merging high accuracy with operational efficiency, paving the way for advanced biometric verification technologies. Full article
(This article belongs to the Special Issue Emerging Artificial Intelligence Technologies and Applications)
Show Figures

Figure 1

23 pages, 10179 KiB  
Article
A Degraded Finger Vein Image Recovery and Enhancement Algorithm Based on Atmospheric Scattering Theory
by Dingzhong Feng, Peng Feng, Yongbo Mao, Yang Zhou, Yuqing Zeng and Ye Zhang
Sensors 2024, 24(9), 2684; https://doi.org/10.3390/s24092684 - 24 Apr 2024
Cited by 1 | Viewed by 1759
Abstract
With the development of biometric identification technology, finger vein identification has received more and more widespread attention for its security, efficiency, and stability. However, because of the performance of the current standard finger vein image acquisition device and the complex internal organization of [...] Read more.
With the development of biometric identification technology, finger vein identification has received more and more widespread attention for its security, efficiency, and stability. However, because of the performance of the current standard finger vein image acquisition device and the complex internal organization of the finger, the acquired images are often heavily degraded and have lost their texture characteristics. This makes the topology of the finger veins inconspicuous or even difficult to distinguish, greatly affecting the identification accuracy. Therefore, this paper proposes a finger vein image recovery and enhancement algorithm using atmospheric scattering theory. Firstly, to normalize the local over-bright and over-dark regions of finger vein images within a certain threshold, the Gamma transform method is improved in this paper to correct and measure the gray value of a given image. Then, we reconstruct the image based on atmospheric scattering theory and design a pixel mutation filter to segment the venous and non-venous contact zones. Finally, the degraded finger vein images are recovered and enhanced by global image gray value normalization. Experiments on SDUMLA-HMT and ZJ-UVM datasets show that our proposed method effectively achieves the recovery and enhancement of degraded finger vein images. The image restoration and enhancement algorithm proposed in this paper performs well in finger vein recognition using traditional methods, machine learning, and deep learning. The recognition accuracy of the processed image is improved by more than 10% compared to the original image. Full article
(This article belongs to the Topic Applications in Image Analysis and Pattern Recognition)
Show Figures

Figure 1

16 pages, 2880 KiB  
Article
Customizable Presentation Attack Detection for Improved Resilience of Biometric Applications Using Near-Infrared Skin Detection
by Tobias Scheer, Markus Rohde, Ralph Breithaupt, Norbert Jung and Robert Lange
Sensors 2024, 24(8), 2389; https://doi.org/10.3390/s24082389 - 9 Apr 2024
Viewed by 1406
Abstract
Due to their user-friendliness and reliability, biometric systems have taken a central role in everyday digital identity management for all kinds of private, financial and governmental applications with increasing security requirements. A central security aspect of unsupervised biometric authentication systems is the presentation [...] Read more.
Due to their user-friendliness and reliability, biometric systems have taken a central role in everyday digital identity management for all kinds of private, financial and governmental applications with increasing security requirements. A central security aspect of unsupervised biometric authentication systems is the presentation attack detection (PAD) mechanism, which defines the robustness to fake or altered biometric features. Artifacts like photos, artificial fingers, face masks and fake iris contact lenses are a general security threat for all biometric modalities. The Biometric Evaluation Center of the Institute of Safety and Security Research (ISF) at the University of Applied Sciences Bonn-Rhein-Sieg has specialized in the development of a near-infrared (NIR)-based contact-less detection technology that can distinguish between human skin and most artifact materials. This technology is highly adaptable and has already been successfully integrated into fingerprint scanners, face recognition devices and hand vein scanners. In this work, we introduce a cutting-edge, miniaturized near-infrared presentation attack detection (NIR-PAD) device. It includes an innovative signal processing chain and an integrated distance measurement feature to boost both reliability and resilience. We detail the device’s modular configuration and conceptual decisions, highlighting its suitability as a versatile platform for sensor fusion and seamless integration into future biometric systems. This paper elucidates the technological foundations and conceptual framework of the NIR-PAD reference platform, alongside an exploration of its potential applications and prospective enhancements. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

18 pages, 8506 KiB  
Article
FV-MViT: Mobile Vision Transformer for Finger Vein Recognition
by Xiongjun Li, Jin Feng, Jilin Cai and Guowen Lin
Sensors 2024, 24(4), 1331; https://doi.org/10.3390/s24041331 - 19 Feb 2024
Cited by 9 | Viewed by 3030
Abstract
In addressing challenges related to high parameter counts and limited training samples for finger vein recognition, we present the FV-MViT model. It serves as a lightweight deep learning solution, emphasizing high accuracy, portable design, and low latency. The FV-MViT introduces two key components. [...] Read more.
In addressing challenges related to high parameter counts and limited training samples for finger vein recognition, we present the FV-MViT model. It serves as a lightweight deep learning solution, emphasizing high accuracy, portable design, and low latency. The FV-MViT introduces two key components. The Mul-MV2 Block utilizes a dual-path inverted residual connection structure for multi-scale convolutions, extracting additional local features. Simultaneously, the Enhanced MobileViT Block eliminates the large-scale convolution block at the beginning of the original MobileViT Block. It converts the Transformer’s self-attention into separable self-attention with linear complexity, optimizing the back end of the original MobileViT Block with depth-wise separable convolutions. This aims to extract global features and effectively reduce parameter counts and feature extraction times. Additionally, we introduce a soft target center cross-entropy loss function to enhance generalization and increase accuracy. Experimental results indicate that the FV-MViT achieves a recognition accuracy of 99.53% and 100.00% on the Shandong University (SDU) and Universiti Teknologi Malaysia (USM) datasets, with equal error rates of 0.47% and 0.02%, respectively. The model has a parameter count of 5.26 million and exhibits a latency of 10.00 milliseconds from the sample input to the recognition output. Comparison with state-of-the-art (SOTA) methods reveals competitive performance for FV-MViT. Full article
(This article belongs to the Special Issue Biometrics Recognition Systems)
Show Figures

Figure 1

Back to TopTop