Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (62)

Search Parameters:
Keywords = electromagnetic acoustic transducer (EMAT)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 9401 KB  
Article
Non-Contact Ultrasonic Assessment of Corrosion in Steel Specimens
by Lukas Peterson, Andrei Zagrai, ThankGod Nwokocha and T. David Burleigh
Sensors 2026, 26(12), 3923; https://doi.org/10.3390/s26123923 - 20 Jun 2026
Viewed by 432
Abstract
Ultrasonic thickness resonance can be effectively used to detect and quantify the level of corrosion in steel nuclear storage containers as well as other corrosion-prone thin-walled structures, such as pipes and storage tanks. Electro-Magnetic Acoustic Transducers (EMATs) have several advantages over more traditional [...] Read more.
Ultrasonic thickness resonance can be effectively used to detect and quantify the level of corrosion in steel nuclear storage containers as well as other corrosion-prone thin-walled structures, such as pipes and storage tanks. Electro-Magnetic Acoustic Transducers (EMATs) have several advantages over more traditional piezoelectric-based transducers; namely, they can be used in a non-contact fashion on robotic platforms, allowing for measurements regardless of surface conditions or temperature. The major challenge of EMAT application is the power required to counteract the low actuation efficiency, which is achieved with a high-power ultrasonic pulse generator and a transformer circuit. Resonance techniques, in which most of the energy is concentrated near structural resonance frequencies, are preferable to improve efficiency of electro-magnetic acoustic measurements. This methodology was applied to 316L stainless steel thin plates subjected to uniform corrosion as well as pitting corrosion imitating different damage scenarios in a nuclear waste container. The resonant peak frequency shift was found to be proportional to the severity of corrosion for minimally corroded samples. However, the complete disappearance of the resonance peak was observed in the samples with severe corrosion damage. The EMAT liftoff distance was studied to quantify its effect on the amplitude, spread, and frequency of resonant peaks. Recommendations for use of EMATs for assessing corrosion damage are presented. The study demonstrates the success of frequency-based detection of corrosion damage in 316L stainless steel used in fabrication of nuclear waste storage containers. Full article
(This article belongs to the Special Issue Novel Sensors for Structural Health Monitoring: 2nd Edition)
Show Figures

Figure 1

29 pages, 521 KB  
Review
Application of Electromagnetic Ultrasonic Testing Technology in Pipeline Defects
by Qingsheng Lan, Riteng Sun, Wenbin Tang, Chunyan Zhang, Yu Liu, Yu Wang, An Lei, Changhui Huang, Shanglong Li, Zhichao Cai and Bo Feng
Coatings 2026, 16(1), 133; https://doi.org/10.3390/coatings16010133 - 19 Jan 2026
Cited by 5 | Viewed by 1921
Abstract
Pipelines, as critical carriers for energy transportation, are prone to defects such as cracks and corrosion during long-term operation. Traditional testing methods exhibit limitations in various aspects, while electromagnetic ultrasonic testing technology, leveraging its advantages of non-contact operation and couplant-free application, has emerged [...] Read more.
Pipelines, as critical carriers for energy transportation, are prone to defects such as cracks and corrosion during long-term operation. Traditional testing methods exhibit limitations in various aspects, while electromagnetic ultrasonic testing technology, leveraging its advantages of non-contact operation and couplant-free application, has emerged as a significant direction for pipeline integrity assessment. This paper analyzes the advantages of EMAT guided wave testing technology in achieving long-distance and rapid screening of pipelines, as well as the strengths of bulk wave testing technology in high-precision quantitative evaluation. It also examines the unique value of obliquely incident SV waves in the directional identification of weld defects. Furthermore, the paper discusses the potential of integrating EMAT with multiple technologies, demonstrating how multi-physical field synergy enhances detection reliability. Finally, it summarizes the remaining challenges in practical engineering applications, providing references for advancing the field toward intelligent and high-precision development. Full article
Show Figures

Figure 1

29 pages, 8365 KB  
Article
Quantitative Residual Stress Analysis in Steel Structures Using EMAT Nonlinear Acoustics
by Kaleeswaran Balasubramaniam, Borja Nuevo Ortiz and Álvaro Pallarés Bejarano
Sensors 2025, 25(22), 7019; https://doi.org/10.3390/s25227019 - 17 Nov 2025
Cited by 1 | Viewed by 1293
Abstract
Residual stress plays a critical role in the durability and structural integrity of steel rolls and bars. Proper analysis helps prevent defects like warping or cracking, ensuring the steel meets quality standards and performs reliably in critical applications. This paper presents a methodology [...] Read more.
Residual stress plays a critical role in the durability and structural integrity of steel rolls and bars. Proper analysis helps prevent defects like warping or cracking, ensuring the steel meets quality standards and performs reliably in critical applications. This paper presents a methodology for analysing residual stresses using electromagnetic acoustic transducer (EMAT) based nonlinear ultrasonics. It compares its effectiveness with established techniques such as X-ray diffraction (XRD) and coercive force measurements. The results demonstrate that nonlinear ultrasonics provides more detailed insights into stress distribution, particularly in subsurface regions where traditional methods like XRD face limitations. It also shows good sensitivity to stress-induced microstructural variations than coercive force measurements. This research study is the first to perform a comparative analysis using XRD, EMAT, and coercive force techniques on industrial samples, followed by the implementation of EMAT nonlinear technology at an industrial production site. The findings indicate a positive trend observed in XRD and coercive force results, and those from nonlinear ultrasonics, further validating its accuracy. Moreover, the technology has been successfully applied in steel manufacturing industries through the project named STEEL components assessment using a novel non-destructive residual stress ultrasonic technology (STEELAR), funded by the Research Fund for Coal and Steel (RFCS). These findings underscore the potential of nonlinear ultrasonics as a powerful, fast and complementary tool for comprehensive residual stress monitoring in steel components, enhancing both theoretical understanding and practical industrial application. Full article
(This article belongs to the Topic Advances in Non-Destructive Testing Methods, 3rd Edition)
Show Figures

Figure 1

22 pages, 5407 KB  
Article
Optimization and Application of Electromagnetic Ultrasonic Transducer for Battery Non-Destructive Testing
by Xuhang Zhan, Zhangwan Li, Hongchao Chen, Guanlin Yu and Xiaoyu Li
Sensors 2025, 25(19), 6003; https://doi.org/10.3390/s25196003 - 29 Sep 2025
Cited by 2 | Viewed by 1750
Abstract
The monitoring of safety and health in lithium-ion batteries (LIBs) presents a significant challenge. Ultrasonic detection techniques fulfil the requirements for high sensitivity and non-destructive evaluation in the safety assessment of these batteries. This study concentrates on the application of electromagnetic acoustic transducer [...] Read more.
The monitoring of safety and health in lithium-ion batteries (LIBs) presents a significant challenge. Ultrasonic detection techniques fulfil the requirements for high sensitivity and non-destructive evaluation in the safety assessment of these batteries. This study concentrates on the application of electromagnetic acoustic transducer (EMAT) technology for non-destructive battery testing, utilizing non-contact electromagnetic coupling to generate and receive ultrasonic waves. This method addresses the limitations associated with conventional piezoelectric ultrasonic coupling media, thereby facilitating highly reliable assessment of the internal condition of batteries. Specifically, this paper independently designs an EMAT featuring a Halbach magnet array and a butterfly coil. Based on this design, optimization is performed, and the amplitude of the received signal is increased fourfold compared to the pre-optimization configuration. The optimized transducer is employed to evaluate a set of retired batteries with a nominal capacity of 270 Ah. Experimental results demonstrate that batteries exhibiting capacities below 240 Ah produced average signal amplitudes more than 40% lower than those of batteries with higher capacities. This technology provides a non-contact, disassembly-free approach for rapid performance evaluation of batteries and demonstrates potential for effective application in sorting retired battery units. Full article
Show Figures

Figure 1

21 pages, 3864 KB  
Article
Sub-MHz EMAR for Non-Contact Thickness Measurement: How Ultrasonic Wave Directivity Affects Accuracy
by Alexander Siegl, David Auer, Bernhard Schweighofer, Andre Hochfellner, Gerald Klösch and Hannes Wegleiter
Sensors 2025, 25(15), 4746; https://doi.org/10.3390/s25154746 - 1 Aug 2025
Cited by 9 | Viewed by 1655
Abstract
Electromagnetic acoustic resonance (EMAR) is a well-established non-contact method for ultrasonic thickness measurement, typically operated at frequencies above 1 MHz using an electromagnetic acoustic transducer (EMAT). This study successfully extends EMAR into the sub-MHz range, allowing supply voltages below 60 V and thus [...] Read more.
Electromagnetic acoustic resonance (EMAR) is a well-established non-contact method for ultrasonic thickness measurement, typically operated at frequencies above 1 MHz using an electromagnetic acoustic transducer (EMAT). This study successfully extends EMAR into the sub-MHz range, allowing supply voltages below 60 V and thus offering safer and more cost-effective operation. Experiments were conducted on copper blocks approximately 20 mm thick, where a relative thickness accuracy of better than 0.2% is obtained. Regarding this result, the research identifies a critical design principle: Stable thickness resonances and subsequently accurate thickness measurement are achieved when the ratio of ultrasonic wavelength to EMAT track width (λ/w) falls below 1. This minimizes the excitation and interactions with structural eigenmodes, ensuring consistent measurement reliability. To support this, the study introduces a system-based model to simulate the EMAR method. The model provides detailed insights into how wave propagation affects the accuracy of EMAR measurements. Experimental results align well with the simulation outcome and confirm the feasibility of EMAR in the sub-MHz regime without compromising precision. These findings highlight the potential of low-voltage EMAR as a safer, cost-effective, and highly accurate approach for industrial ultrasonic thickness measurements. Full article
(This article belongs to the Special Issue Electromagnetic Sensing and Its Applications)
Show Figures

Figure 1

16 pages, 2473 KB  
Article
Improvement of EMAT Butterfly Coil for Defect Detection in Aluminum Alloy Plate
by Dazhao Chi, Guangyu Sun and Haichun Liu
Materials 2025, 18(13), 3207; https://doi.org/10.3390/ma18133207 - 7 Jul 2025
Cited by 5 | Viewed by 1670
Abstract
For non-destructive testing (NDT) of defects in aluminum alloy plates, traditional ultrasonic contact methods face challenges from high temperatures and liquid couplant contamination. Using electromagnetic acoustic transducers (EMATs), a key issue is that longitudinal waves (L-waves) excited by the butterfly-coil EMATs interfere with [...] Read more.
For non-destructive testing (NDT) of defects in aluminum alloy plates, traditional ultrasonic contact methods face challenges from high temperatures and liquid couplant contamination. Using electromagnetic acoustic transducers (EMATs), a key issue is that longitudinal waves (L-waves) excited by the butterfly-coil EMATs interfere with the desired shear waves (S-waves) reflected by internal defects. To solve this problem, a simulation–experiment approach optimized the butterfly coil parameters. An FE model visualized the electromagnetic acoustic transducer (EMAT) acoustic field and predicted signals. Orthogonal simulations tested three main parameters: excitation frequency, wire diameter, and effective coil width. Tests on aluminum specimens with artificial defects used the optimized EMAT. Simulated and measured signals showed strong correlation, validating optimal parameters. The results confirmed suppressed L-wave interference and improved defect detection sensitivity, enabling detection of a 3 mm diameter flat-bottomed hole buried 37 mm deep. Full article
(This article belongs to the Section Metals and Alloys)
Show Figures

Figure 1

24 pages, 10912 KB  
Article
Research on a High-Temperature Electromagnetic Ultrasonic Circumferential Guided Wave Sensor Based on Halbach Array
by Yuanxin Li, Jinjie Zhou, Jiabo Wen, Zehao Wang and Liu Li
Micromachines 2025, 16(4), 367; https://doi.org/10.3390/mi16040367 - 24 Mar 2025
Cited by 7 | Viewed by 1935
Abstract
High-temperature pipelines, as core facilities in the fields of petrochemical and power, are constantly exposed to extreme working conditions ranging from 450 to 600 °C, facing risks of stress corrosion, creep damage, and other defects. Traditional shutdown inspections are time-consuming and costly. Meanwhile, [...] Read more.
High-temperature pipelines, as core facilities in the fields of petrochemical and power, are constantly exposed to extreme working conditions ranging from 450 to 600 °C, facing risks of stress corrosion, creep damage, and other defects. Traditional shutdown inspections are time-consuming and costly. Meanwhile, existing electromagnetic acoustic transducers (EMATs) are restricted by their high-temperature tolerance (≤500 °C) and short-term stability (effective working duration < 5 min). This paper proposes a high-frequency circumferential guided wave (CLamb wave) EMAT based on a Halbach permanent magnet array. Through magnetic circuit optimization (Halbach array) and multi-layer insulation design, it enables continuous and stable detection on the surface of 600 °C pipelines for 10 min. The simulations revealed that the Halbach array increased the magnetic flux density by 1.4 times and the total displacement amplitude by 2 times at a magnet’s large lift-off (9 mm). The experimental results show that the internal temperature of the sensor remained stable below 167 °C at 600 °C. It was capable of detecting the smallest defect of a φ3 mm half-hole (depth half of the wall thickness), with a signal attenuation rate of only 0.32%/min. The signal amplitude of Q235 pipelines under high-temperature short-term detection (<5 min) was 1.5 times higher than that at room temperature. However, material degradation under high temperature led to insufficient long-term stability. This study breaks through the bottleneck of long-term detection of high-temperature EMATs, providing a new scheme for efficient online detection of high-temperature pipelines. Full article
(This article belongs to the Special Issue Acoustic Transducers and Their Applications, 2nd Edition)
Show Figures

Figure 1

23 pages, 2249 KB  
Article
Improved EMAT Sensor Design for Enhanced Ultrasonic Signal Detection in Steel Wire Ropes
by Immanuel Rossteutscher, Oliver Blaschke, Florian Dötzer, Thorsten Uphues and Klaus Stefan Drese
Sensors 2024, 24(22), 7114; https://doi.org/10.3390/s24227114 - 5 Nov 2024
Cited by 9 | Viewed by 3607
Abstract
This study is focused on optimizing electromagnetic acoustic transducer (EMAT) sensors for enhanced ultrasonic guided wave signal generation in steel cables using CAD and modern manufacturing to enable contactless ultrasonic signal transmission and reception. A lab test rig with advanced measurement and data [...] Read more.
This study is focused on optimizing electromagnetic acoustic transducer (EMAT) sensors for enhanced ultrasonic guided wave signal generation in steel cables using CAD and modern manufacturing to enable contactless ultrasonic signal transmission and reception. A lab test rig with advanced measurement and data processing was set up to test the sensors’ ability to detect cable damage, like wire breaks and abrasion, while also examining the effect of potential disruptors such as rope soiling. Machine learning algorithms were applied to improve the damage detection accuracy, leading to significant advancements in magnetostrictive measurement methods and providing a new standard for future development in this area. The use of the Vision Transformer Masked Autoencoder Architecture (ViTMAE) and generative pre-training has shown that reliable damage detection is possible despite the considerable signal fluctuations caused by rope movement. Full article
(This article belongs to the Special Issue Feature Papers in Physical Sensors 2024)
Show Figures

Figure 1

25 pages, 10965 KB  
Article
Bottom Crack Detection with Real-Time Signal Amplitude Correction Using EMAT-PEC Composite Sensor
by Yizhou Guo, Yu Hu, Kai Wang, Yini Song, Bo Feng, Yihua Kang and Zhaoqi Duan
Sensors 2024, 24(16), 5196; https://doi.org/10.3390/s24165196 - 11 Aug 2024
Cited by 10 | Viewed by 3342
Abstract
During electromagnetic ultrasonic testing, it is difficult to recognize small-size bottom cracks by time of flight (ToF), and the lift-off fluctuation of the probe affects the accuracy and consistency of the inspection results. In order to overcome the difficulty, a novel composite sensor [...] Read more.
During electromagnetic ultrasonic testing, it is difficult to recognize small-size bottom cracks by time of flight (ToF), and the lift-off fluctuation of the probe affects the accuracy and consistency of the inspection results. In order to overcome the difficulty, a novel composite sensor of an electromagnetic acoustic transducer (EMAT) and pulse eddy current (PEC) is designed. We use the amplitude of a bottom echo recorded by EMAT to identify the tiny bottom crack as well as the amplitude of PEC signals picked up by the integrated symmetric coils to measure the average lift-off of the probe in real time. Firstly, the effects of lift-off and bottom cracks on the amplitude of bottom echo are distinguished by combining the theoretical analysis and finite element method (FEM). And then an amplitude correction method based on the fusion of EMAT and PEC signals is proposed to reduce the impact of lift-off on the defect signal. The experimental results demonstrate that the designed composite sensor can effectively detect a bottom crack as small as 0.1 mm × 0.3 mm. The signal fusion method can accurately correct the amplitude of defect signals and the relative error is less than ±8%. Full article
(This article belongs to the Special Issue Novel Sensors for Structural Health Monitoring: 2nd Edition)
Show Figures

Figure 1

21 pages, 4988 KB  
Article
An Adaptive Noise Reduction Method for High Temperature and Low Voltage Electromagnetic Detection Signals Based on SVMD Combined with ICEEMDAN
by Zhizeng Ge, Jinjie Zhou, Xingquan Shen, Xingjun Zhang and Caixia Qi
Micromachines 2024, 15(8), 977; https://doi.org/10.3390/mi15080977 - 30 Jul 2024
Cited by 13 | Viewed by 2316
Abstract
In view of the low signal-to-noise ratio (SNR) of shear wave electromagnetic acoustic transducers (EMAT) in the detection of high-temperature equipment, the use of low excitation voltage (LEV) further deteriorates the detection results, resulting in the echo signal containing defects being drowned in [...] Read more.
In view of the low signal-to-noise ratio (SNR) of shear wave electromagnetic acoustic transducers (EMAT) in the detection of high-temperature equipment, the use of low excitation voltage (LEV) further deteriorates the detection results, resulting in the echo signal containing defects being drowned in noise. For the extraction of the EMAT signal, an adaptive noise reduction method is proposed. Firstly, the minimum envelope entropy is taken as the fitness function for the Harris Hawks Optimizer (HHO), and the optimal successive variational mode decomposition (SVMD) balance parameter is searched by HHO adaptive iteration to decompose LEV EMAT signals at high temperatures. Then the filter is carried out according to the excitation center frequency and correlation coefficient threshold function. Then, improved complete ensemble empirical mode decomposition with adaptive noise (ICEEMDAN) is used to decompose the filtered signal and combine the kurtosis factor to select the appropriate intrinsic mode functions. Finally, the signal is extracted by the Hilbert transform. In order to verify the effectiveness of the method, it is applied to the low-voltage detection of 40Cr from 25 °C to 700 °C. The results show that the method not only suppresses the background noise and clutter noise but also significantly improves the SNR of EMAT signals, and most importantly, it is able to detect and extract the 2 mm small defects from the echo signals. It has great application prospects and value in the LEV detection of high-temperature equipment. Full article
(This article belongs to the Special Issue Acoustic Transducers and Their Applications, 2nd Edition)
Show Figures

Figure 1

16 pages, 6766 KB  
Article
Electromagnetic Acoustic Detection of Pipe Defects Hidden above T-Type Support Structures with Circumferential Shear Horizontal Guided Wave
by Xingjun Zhang, Jinjie Zhou, Yang Hu, Yao Liu and Xingquan Shen
Micromachines 2024, 15(4), 550; https://doi.org/10.3390/mi15040550 - 20 Apr 2024
Cited by 7 | Viewed by 3112
Abstract
When pipe defects are generated above the T-type support structure location, it is difficult to distinguish the reflection signals caused by the weld bead at the support structure from the reflection echoes of pipe defects. Therefore, in order to effectively detect pipe defects, [...] Read more.
When pipe defects are generated above the T-type support structure location, it is difficult to distinguish the reflection signals caused by the weld bead at the support structure from the reflection echoes of pipe defects. Therefore, in order to effectively detect pipe defects, a waveform subtraction method with a circumferential shear horizontal (CSH) guided wave is proposed, which is generated by an electromagnetic acoustic transducer (EMAT). First, a CSH0 guided wave mode with a center frequency of 500 kHz is selected to establish a three-dimensional model with and without pipe defects above the support structure. Following this, the influence of different widths of support structures on the echo signal is compared. Moreover, simulation and experimental results are used to compare the influence of different welding qualities on the detection results. Finally, the waveform subtraction method is used to process the simulation and experimental signals, and the influence of pipe defects with different lengths and depths is discussed. The results show that the non-through crack defect of 5 mm × 1 mm (length × depth) can be detected. The results show that this method can effectively detect the cracks by eliminating the influence of the weld echo, which provides a new concept for the detection of the defect above the support structure. Full article
(This article belongs to the Special Issue Acoustic Transducers and Their Applications)
Show Figures

Figure 1

18 pages, 4352 KB  
Article
A Simplified One-Parallel-Element Automatic Impedance-Matching Network Applied to Electromagnetic Acoustic Transducers Driving
by João Pedro T. Andrade, Pedro Leon F. C. Bazan, Vivian S. Medeiros and Alan C. Kubrusly
Automation 2023, 4(4), 378-395; https://doi.org/10.3390/automation4040022 - 1 Dec 2023
Cited by 2 | Viewed by 4443
Abstract
Ultrasonic waves generated and received by electromagnetic acoustic transducers (EMATs) are advantageous in non-destructive testing, mainly due to the ability to operate without physical contact with the medium under test. Nevertheless, they present a main drawback of less efficiency, which leads to a [...] Read more.
Ultrasonic waves generated and received by electromagnetic acoustic transducers (EMATs) are advantageous in non-destructive testing, mainly due to the ability to operate without physical contact with the medium under test. Nevertheless, they present a main drawback of less efficiency, which leads to a lower signal-to-noise ratio. To overcome this, the L-network impedance-matching network is often used in order to ensure maximum power transfer to the EMAT from the excitation electronics. There is a wide range of factors that affect an EMAT’s impedance, apart from the transducer itself; namely, the properties of the specimen material, temperature, and frequency. Therefore, to ensure optimal power transfer, the matching network’s configuration needs to be fine-tuned often. Therefore, the automation of the laborious process of manually adjusting the network is of great benefit to the use of EMAT transducers. In this work, a simplified one-parallel-element automatic matching network is proposed and its theoretical optimal value is derived. Next, an automatic matching network was designed and fabricated. Experiments were performed with two different EMATs at several frequencies obtaining good agreement with theoretical predictions. The automatic system was able to determine the best configuration for the one-element matching network and provided up to 5.6 dB gain, similar to a standard manual solution and considerably faster. Full article
Show Figures

Figure 1

14 pages, 4476 KB  
Communication
Internal and External Pipe Defect Characterization via High-Frequency Lamb Waves Generated by Unidirectional EMAT
by Xu Zhang, Bo Li, Xiaolong Zhang, Xiaochun Song, Jun Tu, Chen Cai, Jundong Yuan and Qiao Wu
Sensors 2023, 23(21), 8843; https://doi.org/10.3390/s23218843 - 31 Oct 2023
Cited by 16 | Viewed by 3229
Abstract
Periodic permanent magnet(PPM) electromagnetic acoustic transducers (EMATs) are commonly employed for axial defect inspection in pipelines. However, the lowest-order shear horizontal waves (SH0) guided waves have difficulties in distinctly differentiating internal and external defects. To enhance the signal-to-noise ratio and resolution, a unidirectional [...] Read more.
Periodic permanent magnet(PPM) electromagnetic acoustic transducers (EMATs) are commonly employed for axial defect inspection in pipelines. However, the lowest-order shear horizontal waves (SH0) guided waves have difficulties in distinctly differentiating internal and external defects. To enhance the signal-to-noise ratio and resolution, a unidirectional electromagnetic acoustic transducer (EMAT) based on Circumferential Lamb waves (CLamb waves) is developed. Through structural parameter optimization and excitation frequency adjustment, high-amplitude and low-dispersion CLamb waves are successfully generated in the high-frequency-thickness product region of the dispersion curve. Finite element simulations and experimental validation confirm the capability of this EMAT in exciting CLamb waves for the detection of crack-like defects. Experimental results demonstrate that the excitation efficiency of the CLamb EMAT exceeds that of the periodic permanent magnet electromagnetic acoustic transducer by more than tenfold. The defect reflection signal of the CLamb EMAT exhibits higher resolution and more significant amplitude compared to the PPM EMAT. The integration of this method with SH0 mode detection allows for the inspection of both internal and external defects in pipelines, offering a new avenue for EMAT applications in pipeline inspection. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

19 pages, 6235 KB  
Article
Antisymmetric Lamb Wave Simulation Study Based on Electromagnetic Acoustic Transducer with Periodic Permanent Magnets
by Lianren Du, Ruizhen Gao and Xiaojuan Jia
Sensors 2023, 23(16), 7117; https://doi.org/10.3390/s23167117 - 11 Aug 2023
Cited by 6 | Viewed by 2318
Abstract
Due to its multi-mode and dispersion characteristics, Lamb waves cause interference to signal processing, which profoundly limits their application in nondestructive testing. To resolve this issue, firstly, based on the traditional EMAT, a horizontal polarization periodic permanent magnet electromagnetic acoustic transducer (HP-PPM-EMAT) was [...] Read more.
Due to its multi-mode and dispersion characteristics, Lamb waves cause interference to signal processing, which profoundly limits their application in nondestructive testing. To resolve this issue, firstly, based on the traditional EMAT, a horizontal polarization periodic permanent magnet electromagnetic acoustic transducer (HP-PPM-EMAT) was proposed. A 2-D finite element model was then developed to compare magnetic flux density, Lorentz force, and signal strength between the traditional EMAT and the HP-PPM-EMAT. The simulation results show that the HP-PPM-EMAT enhances the A0 mode Lamb wave (A0 wave) and suppresses the S0 mode Lamb wave (S0 wave). Finally, the influence of structural parameters of the HP-PPM-EMAT on the total displacement amplitude ratio of A0 and S0 was investigated using orthogonal test theory, and the width of magnet units was improved based on the orthogonal test. The results show that the total displacement amplitude ratio of A0 to S0 of the improved HP-PPM-EMAT can be improved by a factor of 7.74 compared with that of the traditional Lamb wave EMAT, which can produce higher-purity A0 mode Lamb waves. Full article
Show Figures

Figure 1

14 pages, 5242 KB  
Article
Research on Crossing-Pipe Support Structure Defect Detection of EMAT-Excited CSH Wave
by Yang Hu, Jinjie Zhou and Wenying Yue
Sensors 2023, 23(12), 5535; https://doi.org/10.3390/s23125535 - 13 Jun 2023
Cited by 9 | Viewed by 2379
Abstract
A circumferential shear horizontal (CSH) guide wave-detection method using a periodic permanent magnet electromagnetic acoustic transducer (PPM EMAT) was proposed to solve the defect detection located at the inside of the pipe welded by supporting structures. Firstly, a low-frequency CSH0 mode was [...] Read more.
A circumferential shear horizontal (CSH) guide wave-detection method using a periodic permanent magnet electromagnetic acoustic transducer (PPM EMAT) was proposed to solve the defect detection located at the inside of the pipe welded by supporting structures. Firstly, a low-frequency CSH0 mode was selected to establish a three-dimensional equivalent model for the defect detection to cross the pipe support, and the ability of the CSH0 guided wave to propagate through the support and weld structure was analyzed. Then, an experiment was used for the further exploration of the influence of different sizes and types of defects on detection after using the support, as well as the ability of detection mechanism to cross different pipe structures. The results show that both the experiment and the simulation received a good detection signal at 3 mm crack defects, which proves that the method can detect the defects by crossing the welded supporting structure. At the same time, the support structure shows a greater impact on the detection of small defects than the welded structure. The research in this paper can provide ideas for guide wave detection across the support structure in the future. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

Back to TopTop