Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (69)

Search Parameters:
Keywords = class-II cavities

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 2260 KiB  
Article
Comparative Micro-CT Analysis of Internal Adaptation and Closed Porosity of Conventional Layered and Thermoviscous Bulk-Fill Resin Composites Using Total-Etch or Universal Adhesives
by Dóra Jordáki, Virág Veress, Tamás Kiss, József Szalma, Márk Fráter and Edina Lempel
Polymers 2025, 17(15), 2049; https://doi.org/10.3390/polym17152049 - 27 Jul 2025
Viewed by 331
Abstract
Reliable adaptation in Class II resin-based composite (RBC) restorations with margins on cementum remains challenging. This study compared the internal adaptation (IA) and closed porosity (CP) of three restorative strategies for such cavities, using either total-etch or self-etch adhesive approaches. Standardized box-only cavities [...] Read more.
Reliable adaptation in Class II resin-based composite (RBC) restorations with margins on cementum remains challenging. This study compared the internal adaptation (IA) and closed porosity (CP) of three restorative strategies for such cavities, using either total-etch or self-etch adhesive approaches. Standardized box-only cavities were prepared on both proximal surfaces of 30 extracted molars, applying self-etch on mesial and total-etch on distal cavities. Group 1 used a layered microhybrid RBC; Group 2 used a flowable RBC base beneath a layered microhybrid RBC; and Group 3 used a thermoviscous RBC in a 4 mm bulk increment. Micro-computed tomography was employed to assess IA and CP. ANOVA, Tukey post hoc, and univariate analyses were used to evaluate group differences and the effects of adhesive/restorative strategies. Group 2 demonstrated the best adaptation (0.10%), whereas Group 3 exhibited the highest internal gap ratio (0.63%) and the lowest CP (p = 0.006). Total-etch adhesive significantly improved IA compared to self-etch (p < 0.001). These findings emphasize the impact of material selection and adhesive technique on the quality of restorations in cementum-located Class II cavities. Full article
(This article belongs to the Special Issue Advanced Polymeric Materials for Dental Applications III)
Show Figures

Figure 1

24 pages, 2354 KiB  
Systematic Review
Highly Filled Flowable Composite Resins as Sole Restorative Materials: A Systematic Review
by Konstantinos Tzimas, Eftychia Pappa, Maria Fostiropoulou, Efstratios Papazoglou and Christos Rahiotis
Materials 2025, 18(14), 3370; https://doi.org/10.3390/ma18143370 - 18 Jul 2025
Viewed by 453
Abstract
The continuous need for simplified, minimally invasive restorative procedures with a high precision has led to the advancement of highly filled flowable resin-based materials. These materials present excellent initial outcomes in various clinical applications, including the injection molding technique. Given that several clinical [...] Read more.
The continuous need for simplified, minimally invasive restorative procedures with a high precision has led to the advancement of highly filled flowable resin-based materials. These materials present excellent initial outcomes in various clinical applications, including the injection molding technique. Given that several clinical reports present signs of wear and staining, this systematic review aims to investigate the mechanical and optical properties of highly filled flowable composite resins. A comprehensive literature research was conducted to identify relevant studies from the PubMed, the Cochrane Library, and Scopus databases. Data extraction and screening was performed by two independent evaluators. Both in vitro studies and clinical trials were included. A total of thirty-one studies were included in this review. A total of 27 in vitro studies investigated highly filled flowable composite resins independently, or in comparison with conventional composite resins, traditional flowable composites, bulk-fill flowable composites, glass ionomer cements, and compomers. Additionally, four randomized controlled clinical trials (RCTs) compared highly filled flowable composite resins with their conventional counterparts. Highly filled flowable composite resins exhibit adequate optical properties. Despite their significant improvements, their mechanical properties remain inferior to those of medium-viscosity composite resins. These materials demonstrate a favorable initial performance in the injection molding technique. Based on a limited number of RCTs, these materials demonstrate an adequate performance in class I and II restorations; however these findings should be interpreted with caution. The reported drawbacks in laboratory studies may contraindicate their clinical application in extensive cavities, load-bearing areas, and in cases of excessive tooth wear and parafunctional activity. A careful clinical case selection is strongly recommended. Full article
(This article belongs to the Special Issue Properties of Dental Restorative Materials (Volume II))
Show Figures

Figure 1

14 pages, 1165 KiB  
Article
Micro-CT Assessment of Internal and External Void Formation in Class II Restorations of Primary Molars Using Bulk-Fill Composites
by Ralitsa Gigova and Krasimir Hristov
Materials 2025, 18(11), 2621; https://doi.org/10.3390/ma18112621 - 3 Jun 2025
Cited by 1 | Viewed by 358
Abstract
This study aimed to assess the formation of internal and external voids in class II restorations of primary molars using bulk-fill composites with different viscosities through micro-CT analysis. Standardized class II cavities were prepared on 50 extracted intact primary molars. The teeth were [...] Read more.
This study aimed to assess the formation of internal and external voids in class II restorations of primary molars using bulk-fill composites with different viscosities through micro-CT analysis. Standardized class II cavities were prepared on 50 extracted intact primary molars. The teeth were restored with bulk-fill materials of varying viscosity: SDR, Tetric EvoCeram bulk-fill, Viscalor bulk, Cention forte, and a control group (Dyract XP). They were then scanned using a computed microtomograph. The volumes of the internal and external voids were quantified and expressed as percentages (%) of the total restoration volume. The data were analyzed using one-way ANOVA, followed by Tukey’s test (α = 0.05). The detected external and internal voids ranged from 0.19% to 0.62%. The data indicated no significant difference in the formation of external voids among the various bulk-fill materials or the control group (p > 0.05). Significantly fewer internal voids were observed with more flowable materials and when heat was applied (p < 0.05). The highest percentage of internal and external voids was observed when the layering restorative technique was used. It was concluded that in class II bulk-fill composite restorations in primary dentition, the percentages of both external and internal voids were relatively small compared with the entire volume of the restoration and decreased when more flowable materials were used. Full article
(This article belongs to the Section Advanced Composites)
Show Figures

Figure 1

12 pages, 870 KiB  
Review
Class-I and Class-II Restorations with the Application of a Flowable Composite as an Intermediate Layer—A Narrative Review of Clinical Trials
by Anh Duc Nguyen, Kerstin Bitter and Christian Ralf Gernhardt
J. Funct. Biomater. 2025, 16(3), 111; https://doi.org/10.3390/jfb16030111 - 20 Mar 2025
Viewed by 1304
Abstract
The objective of this review is to investigate the effect of an additional layer of flowable composite for cavity lining on the clinical outcome of direct posterior composite restorations. The PICO question (patient, intervention, comparison, and outcome) was stated as follows: Does the [...] Read more.
The objective of this review is to investigate the effect of an additional layer of flowable composite for cavity lining on the clinical outcome of direct posterior composite restorations. The PICO question (patient, intervention, comparison, and outcome) was stated as follows: Does the additional application of a flowable composite as a cavity liner improve the clinical outcome of Class-I and Class-II restorations? The electronic databases MEDLINE, Web of Science, LILAS, and BBO were assessed for identifying relevant clinical studies. After removal of duplicate records, 309 records could be identified and, after a screening of the title and abstract, 20 articles were selected for full-text analysis. Finally, six studies met the eligibility criteria and were included in this review for further investigation. Four of the included studies have a follow-up period of two years, while the other two studies had an observation period of three and seven years, respectively. No significant differences in annual failure rates were observed between restorations with and without a flowable composite liner. Consequently, the additional usage of flowable composites as a cavity liner seems to have no effect on the clinical longevity of direct composite restorations in Class-I and Class-II cavities. Therefore, the application of a flowable composite is a possible option in everyday dental clinical practice. Full article
Show Figures

Figure 1

13 pages, 1795 KiB  
Article
The Influence of Posterior Class II Composite Restoration Location and Techniques on Marginal Sealing
by Mishel Haddad, Diva Lugassy, Mohana Barhum, Tamar Brosh and Shlomo Matalon
Dent. J. 2025, 13(1), 39; https://doi.org/10.3390/dj13010039 - 17 Jan 2025
Viewed by 1788
Abstract
Background/Objectives: The success of treatment and prevention for secondary caries hinges significantly on the techniques employed in Class II composite restoration. Additionally, the location of the restored tooth within the oral cavity has emerged as a potential factor determining the quality of [...] Read more.
Background/Objectives: The success of treatment and prevention for secondary caries hinges significantly on the techniques employed in Class II composite restoration. Additionally, the location of the restored tooth within the oral cavity has emerged as a potential factor determining the quality of the restoration. A comprehensive understanding of these interrelated variables is crucial for advancing the efficacy and durability of dental composite restorations. The aim of this study was to assess how various restoration techniques and the specific location of the tooth restoration in the oral cavity affect marginal sealing, verified by the gap created in the tooth–restoration interface. Methods: Sixty extracted human teeth that had been indicated for orthodontic extraction were collected and embedded into a custom-made holder that was located in one of the four quadrants of a laboratory phantom head. Class II resin composite restorations, using flowable and packable composites, were performed on all teeth using two techniques: Pre-cure and Co-cure. The aging of the restored teeth was conducted using cyclic loading and thermocycling. After aging, the teeth were examined under a scanning electron microscope to measure the gap within the tooth–composite interface. Kolmogorov–Smirnov tests were used to assess the data distribution. Unpaired T-tests were employed to compare the mean gaps between the Pre-cure and Co-cure techniques. Additionally, unpaired T-tests were utilized to compare the mean gaps between the mesial and distal parts of the teeth. The Kruskal–Wallis test was used to compare the mean gaps among the four quadrants. The statistical significance was set at p = 0.05. Results: No significant difference in the gaps between the Pre-cure and Co-cure techniques was found (p = 0.212). The tooth’s location did not generally affect the restoration’s gap interface (p = 0.136). Conclusions: Flowable composites aid in restoring the deep margins of Class II composite restoration. Thus, the potential for further microleakage is similar for both the Pre-cure and Co-cure restoration techniques. The marginal seal of Class II composite restorations is effective when using both Pre-cure and Co-cure techniques, and the restoration site within the oral cavity does not significantly influence the tooth–composite interface seal. Full article
Show Figures

Figure 1

13 pages, 1567 KiB  
Article
Preheated and Injected Bulk-Fill Resin Composites: A Micro-CT Analysis of Internal Voids and Marginal Adaptation in Class II Restorations
by Vanessa Alves de Sá, Hélio Radke Bittencourt, Luiz Henrique Burnett Júnior and Ana Maria Spohr
Materials 2025, 18(2), 327; https://doi.org/10.3390/ma18020327 - 13 Jan 2025
Cited by 3 | Viewed by 1109
Abstract
The aim of this study was to evaluate, in vitro, the void formation and marginal adaptation in Class II cavities restored with preheated and injected bulk-fill resin composites. Eighty third molars received Class II cavities on their mesial and distal surfaces and were [...] Read more.
The aim of this study was to evaluate, in vitro, the void formation and marginal adaptation in Class II cavities restored with preheated and injected bulk-fill resin composites. Eighty third molars received Class II cavities on their mesial and distal surfaces and were randomly distributed into eight groups (n = 10) according to material (Filtek Universal—control, incremental technique; Filtek One Bulk-Fill; Admira Fusion X-tra Bulk-Fill; VisCalor Bulk-Fill) and the temperature of the material (24 °C or 68 °C). The restored teeth were scanned using a SkyScan 1173 microtomograph. The percentage of internal voids (%IV) was analyzed using CTan software (version 1.23.02) and the percentages of continuous margins (%CM) in enamel and dentin were analyzed using Dataviewer software (version 1.5.6.2). The data of %IV and %CM were subjected to two-way ANOVA on ranks, followed by Tukey’s test (α = 0.05). At 24 °C, Filtek Universal had a greater %IV (1.89%) (p < 0.05), which did not differ significantly from that of Admira Fusion X-tra Bulk-Fill (0.29%) (p > 0.05). Filtek One Bulk-Fill (0.07%) and VisCalor Bulk-Fill (0.07%) had lower %IV (p < 0.05). Preheating resulted in a significantly lower %IV for Admira Fusion X-tra Bulk-Fill (p < 0.05). Temperature did not significantly influence marginal adaptation (p > 0.05). VisCalor Bulk-Fill achieved significantly higher %CM in dentin (98%) at 24 °C (p < 0.05). It was concluded that bulk-fill-injected resin composites tend to have fewer internal voids than conventional resin composites using the incremental technique, and the injection of the resin composite into the cavity seems to be more important for marginal adaptation than the preheating procedure. Full article
Show Figures

Figure 1

10 pages, 652 KiB  
Article
Effect of Glass Fiber Reinforcement on Marginal Microleakage in Class II Composite Restorations: An In Vitro Pilot Study
by Csaba Dudás, Emánuel Kardos, Melinda Székely, Lea Ádám, Zsuzsanna Bardocz-Veres, Evelyn Szőllősi, Kinga Mária Jánosi and Bernadette Kerekes-Máthé
Dent. J. 2024, 12(12), 410; https://doi.org/10.3390/dj12120410 - 16 Dec 2024
Cited by 3 | Viewed by 1478
Abstract
Background: Polymerization shrinkage of composite resins affects the marginal closure of direct dental restorations. It is responsible for developing secondary caries and indirectly affects the survival rate of restorations. This study aims to investigate the null hypothesis, which states that there are no [...] Read more.
Background: Polymerization shrinkage of composite resins affects the marginal closure of direct dental restorations. It is responsible for developing secondary caries and indirectly affects the survival rate of restorations. This study aims to investigate the null hypothesis, which states that there are no significant differences in the marginal microleakage of Class II restorations when examined in vitro using different dental adhesives, whether the restoration material used is a composite with glass fiber reinforcement or not. Methods: Class II cavities were prepared on both proximal surfaces of thirty-six extracted human molars. A single-component (Universal VivaPen) and a two-component (Futurabond DC) self-etch adhesive system were used for the restorations in the control group (Charisma Classic) and the experimental group (Charisma Classic with Interlig glass fiber strip). An oblique layering technique and a 40-s soft-start light-curing polymerization were used. After selective pre-isolation, the specimens were placed in a 0.2% methylene blue solution and incubated at 37 °C for 24 h. The teeth were sectioned in the mesiodistal direction, and two examiners examined and graded the extent of dye penetration. Statistical analysis was conducted using the Mann–Whitney U and chi-square tests (p < 0.05). Results: All the composite restorations reinforced with glass fiber showed significantly reduced dye infiltration compared to the control group (p < 0.05). A significant difference (p < 0.05) was also observed between the two adhesives. Conclusions: The null hypothesis was rejected. Glass fiber strips significantly reduced composite restoration microleakage regardless of the adhesive. The marginal fit of the restoration was also influenced by the adhesive system used. Full article
(This article belongs to the Special Issue State of the Art in Dental Restoration)
Show Figures

Figure 1

12 pages, 3433 KiB  
Article
Visibility of Recurrent Caries Through Universal Shade Resin Composite Restorations
by Ryotaro Yago, Chiharu Kawamoto, Di Wu, Takuma Mirokuin, Rafiqul Islam, Monica Yamauti, Hidehiko Sano and Atsushi Tomokiyo
Materials 2024, 17(23), 5815; https://doi.org/10.3390/ma17235815 - 27 Nov 2024
Cited by 1 | Viewed by 863
Abstract
This in vitro study aimed to investigate whether color differences in the stained cavity floor simulating recurrent caries can be detected using various restored resin composites. Artificial teeth were made with conventional resin composite (Estellite Sigma Quick A3; ET), and class V cavities [...] Read more.
This in vitro study aimed to investigate whether color differences in the stained cavity floor simulating recurrent caries can be detected using various restored resin composites. Artificial teeth were made with conventional resin composite (Estellite Sigma Quick A3; ET), and class V cavities were prepared. To simulate the color of caries, a dot was marked in the center of the cavity floor using four different magic pens. The cavities were filled with ET and two universal shade resin composites (UC, Omnichroma; OMI, Essentia Universal; ESS). For photographic analysis, a standard correction color chart was used. The color difference (ΔE00) between (i) the lab value at the center of the cavity and (ii) the average lab value at 1 mm mesial and distal to the center of the cavity was calculated. The data were statistically analyzed using two-way ANOVA (p < 0.05). For visual analysis, 25 dentists were asked to complete a questionnaire to determine whether the color differences were noticeable. In the photographic analysis, UC showed larger ΔE00 values than ET in all colors. Visual analysis revealed higher detection rates for UC than ET. Universal shade resin composite tends to reflect the color of the cavity more effectively than conventional resin composite. Full article
(This article belongs to the Special Issue Recent Research in Restorative Dental Materials)
Show Figures

Figure 1

10 pages, 1005 KiB  
Article
Histological Evaluation of Polyacid-Modified Composite Resin and Conventional Composite Resin Used for Primary Molars Restoration
by Omar A. El Meligy, Hisham I. Othman, Shahad N. Abudawood, Amani A. Al Tuwirqi, Madawi Faisal Alkeheli, Tarek R. Abdelrehim and Dalia M. Talaat
Dent. J. 2024, 12(11), 343; https://doi.org/10.3390/dj12110343 - 28 Oct 2024
Viewed by 3034
Abstract
Background: The present study evaluated the histological outcomes of two dental restorative materials, polyacid-modified composite resin (compomer) and conventional composite resin, in the primary molars of puppies. Materials and Methods: Twenty sound primary molars in four puppies were used. The puppies were rendered [...] Read more.
Background: The present study evaluated the histological outcomes of two dental restorative materials, polyacid-modified composite resin (compomer) and conventional composite resin, in the primary molars of puppies. Materials and Methods: Twenty sound primary molars in four puppies were used. The puppies were rendered unconscious using general anesthesia. Similar cylindrical Class V cavities were prepared in 16 of the 20 selected primary molars. The teeth were divided into three groups: Group I: Eight cavities were restored with compomer; Group II: Eight cavities were restored with conventional composite resin; Group III: Four teeth remained untreated and were used as controls. In Groups I and II, four teeth were examined histologically after 2 weeks and the other four after 6 weeks. The histological findings were analyzed and compared to determine the effects of each type of resin material on the dentine and the pulp. Results: At 6 weeks, the specimens tested for compomer showed obvious destructive changes in the central region and the region of the pulp adjacent to the cavity. The specimens tested for conventional composite resin revealed, at 6 weeks, massive destruction of the pulp tissues and abscess formation was observed. All the specimens tested in the control group showed normal cellularity, normal vascularity, and proper alignment of odontoblast cells. Conclusions: The teeth restored with compomer demonstrated more favorable pulpal reactions when compared with the teeth restored with conventional composite resin after 6 weeks. Full article
Show Figures

Figure 1

16 pages, 1425 KiB  
Article
Influence of Endodontic Cavity Design on Interfacial Voids, Class II Resin Composites Sealing Ability and Tooth Fracture Resistance: An In Vitro Study
by Abdurrahman S. Assalman, Faisal Al Onaizan, Moataz Elgezawi, Khalid S. Almulhim, Moamen A. Abdallah and Dalia Kaisarly
J. Clin. Med. 2024, 13(19), 6024; https://doi.org/10.3390/jcm13196024 - 9 Oct 2024
Cited by 1 | Viewed by 1481
Abstract
Objective: The aim of this in vitro investigation is to study the effect of endodontic cavity design on interfacial voids, class II resin composite sealing ability, and fracture resistance in mandibular premolars. Methods: A total of 48 single-rooted mandibular premolars received [...] Read more.
Objective: The aim of this in vitro investigation is to study the effect of endodontic cavity design on interfacial voids, class II resin composite sealing ability, and fracture resistance in mandibular premolars. Methods: A total of 48 single-rooted mandibular premolars received compound class II preparations with either traditional flare access cavities (group A) or contracted endodontic cavity preparations (group B). Each study group was subdivided according to the coronal restoration into two sub-groups as α and β. In the α group, a microhybrid composite was used after etch-and-rinse bonding technique using an MDP-containing universal adhesive. In the β group, a self-adhesive composite was used as coronal restoration after endodontic treatment (n = 12) for each subgroup. A micro-CT analysis was performed to assess the obturation interfacial voids and tracing of class II cervical interfacial adaptation. The tooth fracture resistance testing was then performed adding an extra group of 12 sound non-prepared teeth, which were tested as the control for fracture strength testing. A one-way ANOVA and post-hoc testing were used together with descriptive statistics for an analysis of the mean values of obturation interfacial voids. A two-way ANOVA was used to assess the fracture resistance test results, and to find the influence of endodontic access design and the type of composite material on the fracture resistance testing. Chi-square testing was employed to analyze the cervical interfacial seal of the class II restorations. Results: A one-way ANOVA revealed that there were no statistically significant differences between test groups in the amount of obturation interfacial voids (p > 0.05). There were no statistically significant differences between test groups in terms of cervical interfacial sealing ability (p > 0.05). A two-way ANOVA revealed that no statistically significant differences between test groups including the control group existed in terms of the fracture resistance testing (p > 0.05). Conclusions: Although it does not improve tooth fracture resistance, the contracted endodontic access cavity does not deteriorate the quality of obturation in terms of the interfacial porosity. The self-adhesive composite does not improve the efficiency of cervical interfacial adaptation or tooth fracture resistance regardless of the endodontic access cavity shape, yet it revealed a substantial load-bearing capacity. Full article
(This article belongs to the Special Issue Current Topics in Endodontics)
Show Figures

Figure 1

14 pages, 3544 KiB  
Article
Comparative Assessment of Pharyngeal Airway Dimensions in Skeletal Class I, II, and III Emirati Subjects: A Cone Beam Computed Tomography Study
by Sara AlAskar, Mohamed Jamal, Amar Hassan Khamis and Ahmed Ghoneima
Dent. J. 2024, 12(10), 301; https://doi.org/10.3390/dj12100301 - 25 Sep 2024
Viewed by 1121
Abstract
The aim of the current study was to evaluate the pharyngeal airway dimensions of individuals with different skeletal patterns in a cohort of the Emirati population. The specific aim was to assess the relationship between pharyngeal airway dimensions and anterior facial height in [...] Read more.
The aim of the current study was to evaluate the pharyngeal airway dimensions of individuals with different skeletal patterns in a cohort of the Emirati population. The specific aim was to assess the relationship between pharyngeal airway dimensions and anterior facial height in relation to different skeletal patterns. This retrospective study was conducted on a sample of 103 CBCT scans of adult Emirati subjects categorized into three groups according to their skeletal classification as indicated by the ANB angle: Class I (n = 35), Class II (n = 46), and Class III (n = 22). All CBCT scans were taken using an i-CAT CBCT imaging machine (Imaging Sciences, Hatfield, PA, USA). The age range of the patients was 19 to 68 years (62 women and 41 men). ANOVA, t-tests, Kruskal–Wallis, and Mann–Whitney tests were employed for comparing means among groups. The correlation coefficient was used to evaluate the association between variables. A p-value of less than 0.05 was considered statistically significant. This study revealed significant associations between various airway parameters and cephalometric measurements. Positive correlations were observed between nasal cavity volume and nasopharynx volume, as well as anterior facial height. Oropharynx volume exhibited positive correlations with hypopharynx volume and total airway volume, and negative correlations with overjet, ANB angle, and patient age. Hypopharynx volume correlated positively with total airway volume and the most constricted area of the airway (MCA). Total airway volume showed positive correlations with MCA and anterior facial height. MCA had negative correlations with ANB angle and patient age. Nasopharynx volume was significantly larger in the skeletal Class I group than in the Class II or Class III groups, while the other airway parameters showed no significant differences among the groups (p > 0.05). Several airway parameters showed a correlation with anterior facial height among the different skeletal patterns. Nasopharyngeal airway volume was significantly larger in the skeletal Class I group than in Class II and III groups in the studied sample. Full article
Show Figures

Figure 1

11 pages, 3185 KiB  
Article
Evaluation of Proximal Contact Tightness and Contact Area of Posterior Composite Resin Restorations
by Cem Peskersoy, Mert Sener, Oguz Baris Gurses, Eda Erbil and Murat Turkun
Appl. Sci. 2024, 14(18), 8335; https://doi.org/10.3390/app14188335 - 16 Sep 2024
Cited by 3 | Viewed by 2767
Abstract
The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three [...] Read more.
The purpose of this study is to evaluate the influence of the matrix system on proximal contact tightness (PCT) of posterior composite resin restorations. Standardized class II cavities on 180 first lower molar dentiform model teeth (Frasaco GmbH, Tettnang, Germany) were prepared. Three groups were formed considering the matrix system: Group-IM: Ivory matrix (Hahnenkratt GmbH, Königsbach-Stein, Germany), Group-OM: Omni matrix (Ultradent, South Jordan, UT, USA), and Group-PM: Palodent V3 sectional matrix (Dentsply, Charlotte, NC, USA). Teeth were restored with resin composite mounted in a manikin head to simulate the clinical environment. Proximal contact tightness (PCT) was measured using a custom-made portable dental pressure meter (PDPM), and the validation of the PCT results was performed with a histogram analysis acquired from bite-wing radiography. All data were statistically analyzed by ANOVA and t-test in SPSS software (v.27.0) (p < 0.05). PM group showed statistically tighter contacts on both mesial (PCTm: 228.28 ± 59.17 N) and distal surfaces (PCTd: 254.91 ± 65.69 N) (p > 0.05). Mesial contacts were found to be significantly tighter than distal contacts among all (p < 0.05). According to the histogram results, only in the PM group, the difference between the mesial and distal areas is significant (p < 0.05). Histogram results confirmed that the tightest contact values were achieved in the PM group, followed by the OM and IM groups, respectively (p < 0.05). The use of sectional matrix systems and separation rings is more effective in creating tighter contact than conventional matrix systems. The use of anatomical wedges will help to create a more natural approximal contour and narrow contact area. Full article
(This article belongs to the Section Applied Dentistry and Oral Sciences)
Show Figures

Figure 1

11 pages, 2465 KiB  
Article
Comparison of Class II Bulk-Fill, Self-Adhesive Composites, Alkasite, and High-Viscosity Glass Ionomer Restorations in Terms of Marginal and Internal Adaptation
by Agnès Sahli, Laurent Daeniker, Isaline Rossier, Luciana Caseiro, Enrico di Bella, Ivo Krejci and Tissiana Bortolotto
Materials 2024, 17(17), 4373; https://doi.org/10.3390/ma17174373 - 4 Sep 2024
Viewed by 1478
Abstract
(1) Background: Restoring decayed teeth in young patients can be challenging. This calls for a simplification of the protocols through new biomaterials. Therefore, the aim of this study was to compare the marginal adaptation delivered by restorative materials applied on class II cavities [...] Read more.
(1) Background: Restoring decayed teeth in young patients can be challenging. This calls for a simplification of the protocols through new biomaterials. Therefore, the aim of this study was to compare the marginal adaptation delivered by restorative materials applied on class II cavities by using a simplified protocol, before and after fatigue test, followed by the assessment of the internal adaptation. (2) Methods: Forty-eight human teeth were divided into six groups (n = 8). Dentinal fluid simulation was performed before restoring the class II cavities: Gr 1—adhesive (Clearfil Universal Bond Quick) and nanohybrid flowable composite (Clearfil Majesty ES Super Low Flow), Gr 2—adhesive (Clearfil Universal Bond Quick) and nanohybrid composite (Clearfil Majesty ES standard), Gr 3—bulk fill self-adhesive composite (Surefil One), Gr 4—bioactive powder-liquid filling material (Cention Forte), Gr 5—universal adhesive (Adhese Universal) and nanohybrid composite resin (Tetric Powerfill); and control group (CT)—high-viscosity glass ionomer (Equia Forte). Marginal adaptation was observed with scanning electron microscopy (SEM) and compared before and after a fatigue test consisting of repeated thermal and mechanical cycles. The specimens were then cut mesio-distally, and internal adaptation was undertaken using SEM again. Repeated measures and one way ANOVA followed by a Fisher’s LSD test and Fisher’s LSD post hoc test were used in order to compare the statistically significant differences among groups. (3) Results: As for the marginal adaptation after loading, Cention Forte (58%) and Equia Forte HT (53%) were statistically equivalent and presented the highest results, followed by Clearfil Majesty ES Standard (32%) and Tetric Powerfill (27%), with Surefil One (8%) and Clearfil Majesty ES Flow Super Low (7%) showing the worst results. In terms of internal adaptation, Cention Forte (85%) and Clearfil Majesty ES Standard (74%) had the highest percentages of continuous margins. Tetric powerfill (56%) and Equia Forte HT (44%) showed statistically significantly lower results, followed by Clearfil Majesty ES Flow Super Low (33%) and eventually Surefil One (17%). (4) Conclusions: This in vitro study showed promising results for the marginal and internal adaptation of alkasite dual cured Cention Forte in the restoration of class II cavities. This material could be considered an interesting restorative alternative for the restoration of deciduous teeth. Full article
Show Figures

Figure 1

14 pages, 2691 KiB  
Article
Influence of Cavity Lining on the 3-Year Clinical Outcome of Posterior Composite Restorations: A Randomized Controlled Clinical Trial
by Anh Duc Nguyen, Natalie Pütz, Mary Michaelis, Kerstin Bitter and Christian Ralf Gernhardt
Dent. J. 2024, 12(5), 128; https://doi.org/10.3390/dj12050128 - 7 May 2024
Cited by 3 | Viewed by 2309
Abstract
The purpose of this randomized, split-mouth-designed controlled and single-blinded clinical study was to evaluate the 3-year clinical performance of Class I and Class II resin composite restorations placed with or without cavity lining with a flowable composite. Fifty patients with treatment needs in [...] Read more.
The purpose of this randomized, split-mouth-designed controlled and single-blinded clinical study was to evaluate the 3-year clinical performance of Class I and Class II resin composite restorations placed with or without cavity lining with a flowable composite. Fifty patients with treatment needs in two premolars or molars were included. One of the teeth was restored using the nanohybrid composite (Grandio®SO, control group), in the test group a high viscosity flowable composite was additionally applied as a first layer. In both groups, the same self-etch adhesive system was applied. Clinical evaluation after 3 years was carried out using the modified USPHS/Ryge criteria. At the 3-year follow-up the recall rate was 92%. Four restorations failed in the test group (8.7%), three due to the loss of vitality and one after fracture. The control group exhibited a cumulative success rate of 100%, while the test group achieved a success rate of 91.3%. This led to significant differences in the annual failure rate (AFR) between the two groups, with rates of 0% and 2.9% (p < 0.05; Mann–Whitney U-test). After 3 years the cumulative survival rate including all restorations was 95.7%. Statistical analysis revealed significant differences for the parameters: tooth vitality, marginal discoloration, success rate, and AFR. The other parameters exhibited no significant differences. Consequently, the nanohybrid composite demonstrated excellent performance over a 3-year period, whereas the utilization of a flowable composite for the cavity lining did not appear to exert a beneficial influence on clinical outcomes. Full article
Show Figures

Graphical abstract

20 pages, 7878 KiB  
Article
Host–Guest Complexation of Itraconazole with Cyclodextrins for Bioavailability Enhancement
by Lenuţa-Maria Şuta, Amalia Ridichie, Adriana Ledeţi, Claudia Temereancă, Ionuţ Ledeţi, Delia Muntean, Matilda Rădulescu, Renata-Maria Văruţ, Claudia Watz, Florentin Crăineanu, Denisa Ivan, Gabriela Vlase and Lavinia Stelea
Pharmaceutics 2024, 16(4), 560; https://doi.org/10.3390/pharmaceutics16040560 - 19 Apr 2024
Cited by 4 | Viewed by 2133
Abstract
Itraconazole is an antifungal agent included in the triazole pharmacological classification that belongs to the BCS class II, characterized by a low solubility in an aqueous medium (of 1 ng/mL, at neutral pH), which is frequently translated in a low oral bioavailability but [...] Read more.
Itraconazole is an antifungal agent included in the triazole pharmacological classification that belongs to the BCS class II, characterized by a low solubility in an aqueous medium (of 1 ng/mL, at neutral pH), which is frequently translated in a low oral bioavailability but with a high permeability. In this sense, it is necessary to find solutions to increase/improve the solubility of itraconazole in the aqueous environment. The main purpose of this study is the preparation and analysis of five different guest–host inclusion complexes containing intraconazole. Initially, a blind docking process was carried out to determine the interactions between itraconazole and the selected cyclodextrins. The second step of the study was to find out if the active pharmaceutical ingredient was entrapped in the cavity of the cyclodextrin, by using spectroscopic and thermal techniques. Also, the antifungal activity of the inclusion complexes was studied to examine if the entrapment of itraconazole influences the therapeutic effect. The results showed that the active substance was entrapped in the cavity of the cyclodextrins, with a molar ratio of 1:3 (itraconazole–cyclodextrin), and that the therapeutic effect was not influenced by the entrapment. Full article
(This article belongs to the Special Issue Cyclodextrins in Drug Delivery, 2nd Edition)
Show Figures

Figure 1

Back to TopTop