Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (43)

Search Parameters:
Keywords = ceiling fans

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 2691 KiB  
Article
Airflow Dynamics for Micro-Wind Environment Optimization and Human Comfort Improvement: Roadshow Design for Theater Stage Spaces
by Yiheng Liu, Menglong Zhang, Wenyang Han, Yufei He, Chang Yi, Yin Zhang and Jin Li
Sensors 2025, 25(14), 4456; https://doi.org/10.3390/s25144456 - 17 Jul 2025
Viewed by 230
Abstract
The optimization of ventilation strategies in high-ceiling theater stage spaces is crucial for improving thermal comfort and energy efficiency. This study addresses the challenge of uneven temperature distribution and airflow stagnation in stage environments by employing computational fluid dynamics (CFD) simulations to evaluate [...] Read more.
The optimization of ventilation strategies in high-ceiling theater stage spaces is crucial for improving thermal comfort and energy efficiency. This study addresses the challenge of uneven temperature distribution and airflow stagnation in stage environments by employing computational fluid dynamics (CFD) simulations to evaluate the effectiveness of different ventilation modes, including natural, mechanical, and hybrid systems. Six airflow organization scenarios were designed based on modifications to structural layout, equipment settings, and mechanical disturbances (e.g., fan integration). Key evaluation indicators such as temperature uniformity coefficient, airflow velocity, and exhaust efficiency were used to assess performance. The results show that a multi-dimensional optimization approach combining spatial adjustments and mechanical disturbances significantly reduced the average temperature from 26 °C to 23 °C and the temperature uniformity coefficient from 2.79 to 1.49. This study contributes a comprehensive design strategy for stage ventilation that improves comfort while minimizing energy consumption, offering practical implications for performance space design and HVAC system integration. Full article
(This article belongs to the Special Issue IoT and Ubiquitous Computing for Smart Building)
Show Figures

Figure 1

18 pages, 1565 KiB  
Article
The Expression of Social Behaviors in Broiler Chickens Grown in Either Conventional or Environmentally Modified Houses During the Summer Season
by Chloe M. O’Brien and Frank W. Edens
Poultry 2025, 4(3), 32; https://doi.org/10.3390/poultry4030032 - 16 Jul 2025
Viewed by 304
Abstract
Environmentally modified housing [EMH; windowless, insulated sidewalls and ceiling, thermostatically controlled ventilation fans) versus conventional housing [CVH; cross-ventilated, insulated ceiling, ceiling fans) improved broiler performance in the summer. The objective of this investigation was to determine whether social behaviors differed between two population [...] Read more.
Environmentally modified housing [EMH; windowless, insulated sidewalls and ceiling, thermostatically controlled ventilation fans) versus conventional housing [CVH; cross-ventilated, insulated ceiling, ceiling fans) improved broiler performance in the summer. The objective of this investigation was to determine whether social behaviors differed between two population densities (0.06 m2/chick [HD] or 0.07 m2/chick [LD]) in these houses. We used a randomized block statistical design, involving houses, population densities, observation times, and bird age. Behaviors were observed weekly, during the morning and the afternoon. Individual observers focused on the group of broilers in one of three defined 26.76 m2 areas in each of the four pens in each house. Aggressive encounters, tail and back pecking, feather eating, thermoregulatory, preening, and flock mobility were recorded. Feather pecking, eating and aggressive encounters were expressed at greater rates in HD birds in CVH. A salt-deficient diet caused increased feather pecking and aggressive encounters, which decreased after correction of the mistake. Increased heat indices (HIs), HD, and greater light intensity in CVH influenced behaviors and mortality more severely than in EMH. In CVH and EMH, burrowing/thermoregulatory/resting activity increased with increasing HIs. Afternoon preening was elevated significantly in EMH. It was concluded that broilers reared in EMH were more comfortable and experienced improved welfare compared to those reared in CVH. Full article
Show Figures

Figure 1

16 pages, 1062 KiB  
Article
Effects of Thermostat Control on Energy Use and Thermal Comfort in Office Rooms Under Different Glazing Ratio
by Haiying Wang, Rongfu Hou, Bjarne W. Olesen, Ongun B. Kazanci and Huxiang Lin
Buildings 2025, 15(14), 2422; https://doi.org/10.3390/buildings15142422 - 10 Jul 2025
Viewed by 264
Abstract
Thermal comfort of occupants is characterized by operative temperature (Top), while thermal environment is usually controlled by air temperature (Ta). For perimeter areas in buildings, the use of Ta in the control may lead to uncomfortable conditions. In this paper, thermostat controls based [...] Read more.
Thermal comfort of occupants is characterized by operative temperature (Top), while thermal environment is usually controlled by air temperature (Ta). For perimeter areas in buildings, the use of Ta in the control may lead to uncomfortable conditions. In this paper, thermostat controls based on air (TC-Ta) and Top (TC-Top) were compared in an office module based on different glazing ratio (GR) and indoor units. The results showed that, for a fan–coil system, with TC-Top, thermal comfort can be better, while for a ceiling panel system thermal comfort was similar with both controls. For fan coils, with TC-Top, Ta in offices became higher in the winter and lower in the summer, which improved thermal comfort along with increased energy use. For both GR conditions, the radiant panel could compensate for the presence of cold/warm surfaces, and it decreased the differences between the two controls, especially during cooling, which made the radiant system more suitable in large GR condition. With TC-Top, for the ceiling panel system, the increment of energy use was quite small. According to the results, under large GR, TC-Top was better for the fan–coil system to assure thermal comfort, and both control methods could be used in ceiling panel system. This study presents a comprehensive comparison of the two control strategies for both convective and radiant systems, highlighting their performance under varying GR conditions. The results also provide guidance for the optimal control of different indoor units under different GR conditions. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

26 pages, 6447 KiB  
Article
Optimizing Thermal Comfort with Adaptive Behaviours in South Australian Residential Buildings
by Szymon Firląg and Artur Miszczuk
Energies 2025, 18(13), 3498; https://doi.org/10.3390/en18133498 - 2 Jul 2025
Viewed by 236
Abstract
This study focuses on thermal comfort in residential buildings within the Iron Triangle area of South Australia, examining how indoor conditions influence residents’ comfort and adaptive behaviours. Conducted from June 2023 to February 2024 across 30 homes in Port Pirie, Port Augusta, and [...] Read more.
This study focuses on thermal comfort in residential buildings within the Iron Triangle area of South Australia, examining how indoor conditions influence residents’ comfort and adaptive behaviours. Conducted from June 2023 to February 2024 across 30 homes in Port Pirie, Port Augusta, and Whyalla, the research gathered data from 38 residents, who reported indoor comfort levels in living rooms and bedrooms. A total of 3540 responses were obtained. At the same time, the measurement of indoor conditions in the buildings was performed using a small HOBO MX1104 device. Using the Mean Thermal Sensation Vote (MTSV) concept, it was possible to determine the neutral operative temperature and temperature ranges for thermal comfort categories. According to the defined linear regression formula, the neutral temperature was 23.9 °C. In living rooms, it was slightly lower, at 23.7 °C, and in bedrooms, slightly higher, at 24.4 °C. For comparison, the neutral temperature was calculated based on the average Predicted Mean Vote (MPMV) and equal to 24.3 °C. Comparison of the regression curves showed that in terms of slope, the MPMV curve is steeper (slope 0.282) than the MTSV curve (slope 0.1726), and lies above it. Regarding the residents’ behaviour, a strong correlation was found between the operative temperature To and the degree of clothing Icl in living rooms. Use of ceiling fans was also studied. A clear trend was also observed regarding window and door opening. The findings of the research can be used to inform the design and operation of residential buildings with a view to enhancing thermal comfort and energy efficiency. Full article
Show Figures

Figure 1

37 pages, 13736 KiB  
Article
Identification of the Aeroacoustic Emission Source Regions Within a Ceiling Swirl Diffuser
by Philipp Ostmann, Martin Kremer and Dirk Müller
Acoustics 2025, 7(1), 9; https://doi.org/10.3390/acoustics7010009 - 24 Feb 2025
Viewed by 768
Abstract
The acoustic emissions of ventilation systems and their subcomponents contribute to the perceived overall comfort in indoor environments and are, therefore, the subject of research. In contrast to fans, there is little research on the aeroacoustic properties of air diffusers (often referred to [...] Read more.
The acoustic emissions of ventilation systems and their subcomponents contribute to the perceived overall comfort in indoor environments and are, therefore, the subject of research. In contrast to fans, there is little research on the aeroacoustic properties of air diffusers (often referred to as outlets). This study investigates a commercially available ceiling swirl diffuser. Using a hybrid approach, a detailed three-dimensional large-eddy simulation is coupled with a perturbed wave equation to capture the aeroacoustic processes within the diffuser. The flow model is validated for the investigated operating point of 470 m3/h using laser-optical and acoustic measurements. To identify the noise sources, the acoustic pressure is sampled with various receivers and on cut sections to evaluate the cross-power spectral density, and the sound-pressure level distribution on cut sections is evaluated. It is found that the plenum attenuates the noise near its acoustic eigenmodes and thus dominates other noise sources by several orders of magnitude. By implementing the plenum walls as sound-absorbing, the overall sound-pressure level is predicted to decrease by nearly 10 dB/Hz. Other relevant geometric features are the mounting beam and the guide elements, which are responsible for flow-borne noise emissions near 698 Hz and 2699 Hz, respectively. Full article
Show Figures

Graphical abstract

25 pages, 4996 KiB  
Review
Effect of Different Mechanical Fans on Virus Particle Transport: A Review
by Xiaofei Han, Norhayati Mahyuddin, Mingyuan Qin, Puyi Wang, Changchang Zhang, Yixuan Wei and Song Pan
Buildings 2025, 15(3), 303; https://doi.org/10.3390/buildings15030303 - 21 Jan 2025
Viewed by 1208
Abstract
In recent years, repeated outbreaks of airborne viruses have normalized human coexistence with these viruses. The complex turbulence and vortices generated by different fan types and operation modes affect virus removal effectiveness. This paper reviews the potential impact and actual effectiveness of different [...] Read more.
In recent years, repeated outbreaks of airborne viruses have normalized human coexistence with these viruses. The complex turbulence and vortices generated by different fan types and operation modes affect virus removal effectiveness. This paper reviews the potential impact and actual effectiveness of different fans in mitigating indoor virus transmission, highlighting their advantages and limitations. Downward rotating ceiling fans can rapidly dilute virus concentration (21–87%) in the breathing zone due to jet cores, with efficiency depending on rotational speed and particle diameter. However, the reprocessing problems of large particles being deposited on surfaces, and small particles settling and rebounding into the air remain unresolved. Upward-rotating ceiling fans do not contribute to indoor virus removal. Exhaust fans generate a negative-pressure environment, which helps expel viruses quickly. But improper vortex zones can increase virus retention time 16–40 times. Air-apply fans effectively dilute and transport viruses only when delivering airflow exceeding 0.5 m/s directly into the breathing zone. Additionally, combined fan strategies remain underexplored, despite potential benefits. This review underscores the need for standardized definitions of particle removal effectiveness and calls for further research on how climatic conditions and thermal comfort influence fan-based interventions. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

28 pages, 8618 KiB  
Article
Performance Evaluation of Ceiling Cooling with PCM in the Hot-Dry Climate of Yazd, Iran: An Experimental Analysis of Energy, Environmental, and Economic Impacts
by Mehran Rabani, Mina Alafzadeh and Mehrdad Rabani
Buildings 2025, 15(2), 198; https://doi.org/10.3390/buildings15020198 - 10 Jan 2025
Cited by 2 | Viewed by 1361
Abstract
The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was [...] Read more.
The present study investigates experimental cooling from the ceiling using phase change materials (PCMs) in Yazd, a city characterized by a hot and dry climate. A one-fourth scale model of a real room, measuring 4 m × 3 m × 3 m, was employed for the analysis. To evaluate system performance and the impact of PCM on energy consumption reduction, three configurations were considered: a simple PCM system, a PCM system with a fan (PCM-F), and a PCM system with a mini cooler (PCM-C). Additionally, to assess the influence of window configurations on ventilation, temperature, and comfort conditions within the model, three scenarios were examined: two open windows, one open window, and no windows. The economic analysis compared the two systems with the fan and mini cooler against a full mechanical cooling system without PCMs. Furthermore, CO2 emissions and environmental impacts associated with the systems were also evaluated. The results indicate that the presence of PCMs in the ceiling, due to heat absorption during phase change, leads to a temperature reduction of 5 to 10 °C in the ceiling and a 3.2 °C reduction in the average room temperature compared to the scenario without PCMs. The findings demonstrate that ceiling cooling with PCMs significantly contributes to energy consumption reduction during peak hours of cooling demand. Specifically, the PCM-F system results in a 92% reduction, and the PCM-C system leads to a 71% reduction in total cost compared to the reference mechanical cooling system. Additionally, the PCM-F system achieves approximately a 36% reduction, and the PCM-C system results in a 34% reduction in environmental impact relative to the reference full mechanical cooling system. Full article
(This article belongs to the Collection Buildings for the 21st Century)
Show Figures

Figure 1

18 pages, 9459 KiB  
Article
Design and Experimental Results of an AIoT-Enabled, Energy-Efficient Ceiling Fan System
by Hashim Raza Khan, Wajahat Ahmed, Wasiq Masud, Urooj Alam, Kamran Arshad, Khaled Assaleh and Saad Ahmed Qazi
Sustainability 2024, 16(12), 5047; https://doi.org/10.3390/su16125047 - 13 Jun 2024
Cited by 2 | Viewed by 3282
Abstract
With technological advancements, domestic appliances are leveraging smart technologies for getting smarter through learning from their past usage to enhance user comfort and energy efficiency. Among these, ceiling fans, though widely used in Lower- and Middle-Income Countries (LMICs) in temperate regions, still lack [...] Read more.
With technological advancements, domestic appliances are leveraging smart technologies for getting smarter through learning from their past usage to enhance user comfort and energy efficiency. Among these, ceiling fans, though widely used in Lower- and Middle-Income Countries (LMICs) in temperate regions, still lack a cohesive system integrating all necessary sensors with a machine learning-based system to optimize their operation for comfort and energy saving and to experimentally verify the performance under different usage scenarios that could transform a high-power-consuming device into an energy-efficient system. Therefore, the present research proposes an experimentally verified and energy-efficient Artificial Intelligence of Things (AIoT)-based system that could be retrofitted with regular DC ceiling fans. An Internet of Things (IoTs) circuit, equipped with an ESP8266 microcontroller, temperature, humidity, and motion sensors, was designed to communicate with a developed Android application and an online dashboard. A total of 123 ceiling fans with the designed IoTs circuit were deployed at various household locations for two years, with manual operations for the first year. In the next year, an auto mode based on the predictions of the machine learning model was introduced. The experimental outcomes showed that the fan with added smart features reduced the energy loss by almost 50% as compared to conventional AC ceiling fans. Consequently, the carbon footprint of the appliances is reduced significantly. A high user-rated acceptability of the system, examined through a standard measure, was also achieved. Full article
Show Figures

Figure 1

17 pages, 6020 KiB  
Article
Enhancement of Indoor Air Quality with a Displacement Ventilation System Comprising a 4-Way Fan Coil Unit and Multiple Air Purifiers
by Su-Hoon Park, Ik-Hyun An, Yong-Ho Lee, Sang-Hyun Cho, Chang-Hoon Lee, Sang-Bum Seo, Hyun-Woo Lee and Se-Jin Yook
Sustainability 2024, 16(5), 1740; https://doi.org/10.3390/su16051740 - 20 Feb 2024
Cited by 2 | Viewed by 2664
Abstract
In indoor spaces without mechanical ventilation systems, a common approach involves using a ceiling-mounted 4-way fan coil unit (4WFCU) to regulate indoor temperature and placing floor-level air purifiers (APs) to remove indoor pollutants. This study introduces a differentiated displacement ventilation system (DVS) that [...] Read more.
In indoor spaces without mechanical ventilation systems, a common approach involves using a ceiling-mounted 4-way fan coil unit (4WFCU) to regulate indoor temperature and placing floor-level air purifiers (APs) to remove indoor pollutants. This study introduces a differentiated displacement ventilation system (DVS) that connects multiple APs to the 4WFCU using ductwork. The age of air was compared between the case where the newly designed DVS was implemented and the reference case where 4WFCU and APs operated independently. When there were no obstacles in the office central area, the reference system exhibited a lower age of air. Conversely, when obstacles such as desks and partitions were present in the central area, the proposed DVS was found to improve indoor air quality. The DVS resulted in minimal interference among pathlines of the air discharged from multiple floor-level APs and their efficient suction through the ceiling-mounted 4WFCU and diffusers, significantly reducing stagnant air zones, while pathlines of the air discharged from the 4WFCU and APs interfered significantly when they operated independently, leading to larger stagnant areas in the air distribution. Therefore, modifying office spaces with ceiling-mounted 4WFCUs using the proposed DVS is anticipated to substantially enhance indoor air quality through a straightforward installation process. Full article
(This article belongs to the Topic Ventilation and Indoor Air Quality, 2nd Edition)
Show Figures

Figure 1

21 pages, 554 KiB  
Article
Exploring Information and Comfort Expectations Related to the Use of a Personal Ceiling Fan
by Romina Rissetto and Marcel Schweiker
Buildings 2024, 14(1), 262; https://doi.org/10.3390/buildings14010262 - 17 Jan 2024
Cited by 1 | Viewed by 1958
Abstract
Rising global temperatures have increased the need for research into human adaptability and comfort in buildings. To reduce comfort-related energy demands, low-energy-consumption alternatives for space cooling, such as personal environmental control systems (PECS), are being investigated. The implementation of PECS in office buildings [...] Read more.
Rising global temperatures have increased the need for research into human adaptability and comfort in buildings. To reduce comfort-related energy demands, low-energy-consumption alternatives for space cooling, such as personal environmental control systems (PECS), are being investigated. The implementation of PECS in office buildings is still underway, and little is known about how occupants’ expectations can influence their satisfaction with PECS and indoor environmental quality. This study examines the influence of tailored information and occupants’ comfort expectations on their thermal perceptions and satisfaction with a personal ceiling fan. Seventy-six participants completed an online questionnaire and attended a half-day session at 30 °C in a climate chamber in Germany. A manipulation technique to activate personal norms was used to test the influence of information on expectations. Results indicated higher reported thermal comfort in participants with more positive thermal expectations, regardless of their expectations of the building systems. These effects were largely moderated by personal norms, indicating the importance of activating normative motivations to increase thermal comfort. Occupants with negative expectations improved their perceptions of the fan when making personal adjustments to stay comfortable. However, this effect was not moderated by personal norms. Practical implications focus on manipulating occupants’ comfort expectations, e.g., by providing occupants with normative messages and individual control, to achieve greater comfort and acceptance of personal building controls in naturally ventilated buildings. Full article
(This article belongs to the Special Issue Thermal Comfort in Built Environment: Challenges and Research Trends)
Show Figures

Figure 1

20 pages, 17796 KiB  
Article
Comparison of Local Mean Age of Air between Displacement Ventilation System and Mixing Ventilation System in Office Heating Conditions during Winter
by Ik-Hyun An, Su-Hoon Park, Yong-Ho Lee, Chang-Hoon Lee, Sang-Bum Seo, Sang-Hyun Cho, Hyun-Woo Lee and Se-Jin Yook
Buildings 2024, 14(1), 115; https://doi.org/10.3390/buildings14010115 - 1 Jan 2024
Cited by 4 | Viewed by 2892
Abstract
A novel displacement ventilation system (DVS) was designed using a four-way cassette fan coil unit (FCU) and air purifiers (APs) for supplying clean air. The proposed DVS in this study involved drawing indoor air through the FCU and diffusers installed in the ceiling, [...] Read more.
A novel displacement ventilation system (DVS) was designed using a four-way cassette fan coil unit (FCU) and air purifiers (APs) for supplying clean air. The proposed DVS in this study involved drawing indoor air through the FCU and diffusers installed in the ceiling, controlling air temperature using the FCU, and then discharging it back into the office through the APs placed on the floor. The comparative ventilation system considered was the typical mixing ventilation system (MVS) that intakes and exhausts indoor air using diffusers installed on the ceiling. The local mean age of air was used as an index to compare indoor air quality between DVS and MVS under winter heating conditions. It was found that the DVS was more effective in improving indoor air quality in winter than the MVS. Moreover, compared to the MVS, utilizing the DVS designed in this study resulted in the advantage of a much more uniform air temperature variation in the office space. Therefore, it is anticipated that modifying the structure of an indoor space with an FCU installed in the ceiling and APs on the floor to use the DVS designed in this study would greatly assist in enhancing indoor air quality. Full article
(This article belongs to the Topic Indoor Air Quality and Built Environment)
Show Figures

Figure 1

12 pages, 3002 KiB  
Technical Note
Thermal Conditions of Laying Quail Sheds in Brazil
by Evandro Menezes de Oliveira, Sheila Tavares Nascimento, João Victor do Nascimento Mós, Lenilson da Fonseca Roza, Juliana Beatriz Toledo and Tatiana Carlesso dos Santos
AgriEngineering 2023, 5(4), 2314-2325; https://doi.org/10.3390/agriengineering5040142 - 6 Dec 2023
Cited by 2 | Viewed by 1780
Abstract
This study was conducted to survey the level of technification of quail sheds in Brazil. Data from 25 quail farms (5 in each Brazilian region) were collected by image analysis of videos available on the Internet. The analyzed variables were farm location, degree [...] Read more.
This study was conducted to survey the level of technification of quail sheds in Brazil. Data from 25 quail farms (5 in each Brazilian region) were collected by image analysis of videos available on the Internet. The analyzed variables were farm location, degree of technological adoption in quail sheds, housing conditions, structural conditions, wall conditions, and thermal comfort equipment. The data were subjected to descriptive analysis, and differences were assessed using the chi-squared test (p < 0.10). It was found that curtain walls were the most used system for air entry and renewal in quail sheds. Fan systems were present in only 12% of sheds, and evaporative cooling systems (or air conditioning) were observed in 4% of sheds, exclusively on large farms. Internal insulation was used in 20.83% of farms. In conclusion, Brazilian quail sheds have a low degree of technification; about 90% do not use implements such as ceiling, ventilation, and cooling systems. These conditions make it difficult to control environmental variables within quail sheds, impairing thermal comfort and, consequently, animal welfare and quail productivity. Full article
(This article belongs to the Section Livestock Farming Technology)
Show Figures

Figure 1

34 pages, 26716 KiB  
Article
Energy Performance of Room Air-Conditioners and Ceiling Fans in Mixed-Mode Buildings
by Sriraj Gokarakonda, Christoph van Treeck, Rajan Rawal and Stefan Thomas
Energies 2023, 16(19), 6807; https://doi.org/10.3390/en16196807 - 25 Sep 2023
Cited by 1 | Viewed by 3781
Abstract
Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space [...] Read more.
Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space cooling. However, there is little empirical evidence on the energy savings from using ceiling fans with Room Air-Conditioners (RACs). To address this gap, we analysed the energy performance of RACs with both fixed-speed compressors and inverter technology at different set-point temperatures and ceiling fan speed settings in 15 residential Mixed-Mode Buildings (MMBs) in India. Thermal comfort conditions (as predicted by the Indian Model for Adaptive Comfort-Residential (IMAC-R)) with minimum energy consumption were maintained at a set-point temperature (Tset) of 28 and 30 C and a fan speed setting of one. Compared with a Tset of 24 °C, a Tset of 28 and 30 °C resulted in energy savings of 44 and 67%, respectively. With the use of RACs, a configuration with a minimum fan speed was satisfactory for an optimal use of energy and for maintaining the conditions of thermal comfort. In addition, RACs with inverter technology used 34–68% less energy than fixed-speed compressors. With the rising use of RACs, particularly in tropical regions, the study’s outcomes offer a significant potential for reducing space-cooling energy consumption and the resultant greenhouse gas (GHG) emissions. Full article
(This article belongs to the Topic Building Energy Efficiency)
Show Figures

Figure 1

17 pages, 16344 KiB  
Article
Indoor Climate Monitoring in Office Buildings—Comparative Analysis of Two Office Buildings without Air Conditioning
by Karsten Voss, Tjado Voß and Marvin Kaliga
Energies 2023, 16(19), 6790; https://doi.org/10.3390/en16196790 - 24 Sep 2023
Cited by 1 | Viewed by 1795
Abstract
Against the background of climate protection and the rising costs of a fossil-fuel-based energy supply, the interest in the energy performance and indoor climate of buildings in real operation is rising. This paper, therefore, deals with the indoor climate investigation of two medium-sized [...] Read more.
Against the background of climate protection and the rising costs of a fossil-fuel-based energy supply, the interest in the energy performance and indoor climate of buildings in real operation is rising. This paper, therefore, deals with the indoor climate investigation of two medium-sized office buildings in Germany by taking measurements over a whole year. These relate to one new building and one refurbished building. Sensors of various types were installed and operated in a large number of office rooms, so that in total results are available for over 100 rooms, typically occupied by one or two persons. The analysis focuses on the indoor temperature in summer and the air quality in winter based on the CO2 concentration. The comfort classes according to DIN EN 16798 including the adaptive comfort approach are used as a basis to cluster the results. Both buildings have movable sun protection and openable windows but no facilities for active cooling. They, thus, represent a large number of existing ‘low tech’ office buildings in Germany and central Europe. The results reflect the respective building concepts but also show a wide range between the rooms due to the user preferences and behaviour. The refurbished building shows better results, especially in terms of air quality but also in terms of summer room temperatures. This underlines the benefit of the targeted measures as a result of an analysis of the deficits in the existing building before the refurbishment. The additional measures for decentralised mechanical ventilation and passive cooling are having positive effects. As part of the projects, further measures to improve the indoor climate were investigated in both buildings. In one case, this involved CO2 traffic lights to stimulate personal window ventilation in winter, and in the other, the use of newly developed individual ceiling fans supports convective heat dissipation on the human body during hot spells in summer. The positive effect could be demonstrated for both measures. Full article
Show Figures

Figure 1

23 pages, 3169 KiB  
Article
Comparison of Portable and Large Mobile Air Cleaners for Use in Classrooms and the Effect of Increasing Filter Loading on Particle Number Concentration Reduction Efficiency
by Finn Felix Duill, Florian Schulz, Aman Jain, Berend van Wachem and Frank Beyrau
Atmosphere 2023, 14(9), 1437; https://doi.org/10.3390/atmos14091437 - 14 Sep 2023
Cited by 4 | Viewed by 2375
Abstract
This study focuses on the effect of portable and large filter-based air cleaners (HEPA filters), which became popular indoors during the COVID-19 pandemic, and their suitability for classrooms (here 186 m3). The decay rates of the particle number concentration (PNC) were [...] Read more.
This study focuses on the effect of portable and large filter-based air cleaners (HEPA filters), which became popular indoors during the COVID-19 pandemic, and their suitability for classrooms (here 186 m3). The decay rates of the particle number concentration (PNC) were measured simultaneously at up to four positions in the room. It was found that the different air outlet configurations of the units have an effect on the actual PNC removal in the room when operated at the same volume flow rates. This effect of the airflow efficiency of the air cleaners (AP) in a classroom is quantified with an introduced Air Cleaning Efficiency Factor in this study to identify beneficial airflows. In this context, the effect of filter loading in long-term operation on the cleaning effect is also investigated. The emitted sound pressure levels of the APs are given special attention as this is a critical factor for use in schools, as well as power consumption. A total of six different devices were tested—two portable APs and four large APs. In order to achieve the necessary volume flow rates, three or four of the portable units were used simultaneously in one room, while only one of the large units was used per room. When used at the same air circulation rates in the room, the portable APs exhibit higher sound pressure levels compared to the large APs. At air circulation rates of 4–5 h−1, the portable APs exceeded a value of 45 dB(A). Two of the four large units reach sound pressure levels below 40 dB(A) at air circulation rates of 4–5 h−1, whereby both large units, which are positioned on the rear wall, realize a homogeneous dilution of the room air. This is achieved by an air outlet directed horizontally at a height above 2 m or diagonally towards the ceiling, which points into the room and partly to the sides. On the other hand, an air outlet directed exclusively to the sides or horizontally into the room at floor level to all sides achieves lower particle decay rates. To investigate the influence of the filter loading, three large APs were operated in a school for a period of one year (190 days with 8 h each). For the three APs, long-term operation leads to different changes in PNC reduction efficiency, ranging from −3% to −34%. It is found that not only the size of the prefilter and main filter has a significant influence, but also whether there is a prefilter bypass that negatively affects the loading level of the main filter. At the same time, it was shown that one type of AP, measuring the pressure drop across the filters and readjusting the fan, kept the circulation rate almost constant (up to −3%) over a year. Full article
Show Figures

Figure 1

Back to TopTop