Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (136)

Search Parameters:
Keywords = cable power losses

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2448 KiB  
Article
A Body-Powered Underactuated Prosthetic Finger Driven by MCP Joint Motion
by Worathris Chungsangsatiporn, Chaiwuth Sithiwichankit, Ratchatin Chancharoen, Ronnapee Chaichaowarat, Nopdanai Ajavakom and Gridsada Phanomchoeng
Robotics 2025, 14(8), 107; https://doi.org/10.3390/robotics14080107 - 31 Jul 2025
Viewed by 287
Abstract
This study presents the design, fabrication, and clinical validation of a lightweight, body-powered prosthetic index finger actuated via metacarpophalangeal (MCP) joint motion. The proposed system incorporates an underactuated, cable-driven mechanism combining rigid and compliant elements to achieve passive adaptability and embodied intelligence, supporting [...] Read more.
This study presents the design, fabrication, and clinical validation of a lightweight, body-powered prosthetic index finger actuated via metacarpophalangeal (MCP) joint motion. The proposed system incorporates an underactuated, cable-driven mechanism combining rigid and compliant elements to achieve passive adaptability and embodied intelligence, supporting intuitive user interaction. Results indicate that the prosthesis successfully mimics natural finger flexion and adapts effectively to a variety of grasping tasks with minimal effort. This study was conducted in accordance with ethical standards and approved by the Institutional Review Board (IRB), Project No. 670161, titled “Biologically-Inspired Synthetic Finger: Design, Fabrication, and Application.” The findings suggest that the device offers a viable and practical solution for individuals with partial hand loss, particularly in settings where electrically powered systems are unsuitable or inaccessible. Full article
(This article belongs to the Section Neurorobotics)
Show Figures

Figure 1

18 pages, 1587 KiB  
Article
Management of Mobile Resonant Electrical Systems for High-Voltage Generation in Non-Destructive Diagnostics of Power Equipment Insulation
by Anatolii Shcherba, Dmytro Vinnychenko, Nataliia Suprunovska, Sergy Roziskulov, Artur Dyczko and Roman Dychkovskyi
Electronics 2025, 14(15), 2923; https://doi.org/10.3390/electronics14152923 - 22 Jul 2025
Viewed by 250
Abstract
This research presents the development and management principles of mobile resonant electrical systems designed for high-voltage generation, intended for non-destructive diagnostics of insulation in high-power electrical equipment. The core of the system is a series inductive–capacitive (LC) circuit characterized by a high quality [...] Read more.
This research presents the development and management principles of mobile resonant electrical systems designed for high-voltage generation, intended for non-destructive diagnostics of insulation in high-power electrical equipment. The core of the system is a series inductive–capacitive (LC) circuit characterized by a high quality (Q) factor and operating at high frequencies, typically in the range of 40–50 kHz or higher. Practical implementations of the LC circuit with Q-factors exceeding 200 have been achieved using advanced materials and configurations. Specifically, ceramic capacitors with a capacitance of approximately 3.5 nF and Q-factors over 1000, in conjunction with custom-made coils possessing Q-factors above 280, have been employed. These coils are constructed using multi-core, insulated, and twisted copper wires of the Litzendraht type to minimize losses at high frequencies. Voltage amplification within the system is effectively controlled by adjusting the current frequency, thereby maximizing voltage across the load without increasing the system’s size or complexity. This frequency-tuning mechanism enables significant reductions in the weight and dimensional characteristics of the electrical system, facilitating the development of compact, mobile installations. These systems are particularly suitable for on-site testing and diagnostics of high-voltage insulation in power cables, large rotating machines such as turbogenerators, and other critical infrastructure components. Beyond insulation diagnostics, the proposed system architecture offers potential for broader applications, including the charging of capacitive energy storage units used in high-voltage pulse systems. Such applications extend to the synthesis of micro- and nanopowders with tailored properties and the electrohydropulse processing of materials and fluids. Overall, this research demonstrates a versatile, efficient, and portable solution for advanced electrical diagnostics and energy applications in the high-voltage domain. Full article
(This article belongs to the Special Issue Energy Harvesting and Energy Storage Systems, 3rd Edition)
Show Figures

Figure 1

36 pages, 7426 KiB  
Article
PowerLine-MTYOLO: A Multitask YOLO Model for Simultaneous Cable Segmentation and Broken Strand Detection
by Badr-Eddine Benelmostafa and Hicham Medromi
Drones 2025, 9(7), 505; https://doi.org/10.3390/drones9070505 - 18 Jul 2025
Viewed by 547
Abstract
Power transmission infrastructure requires continuous inspection to prevent failures and ensure grid stability. UAV-based systems, enhanced with deep learning, have emerged as an efficient alternative to traditional, labor-intensive inspection methods. However, most existing approaches rely on separate models for cable segmentation and anomaly [...] Read more.
Power transmission infrastructure requires continuous inspection to prevent failures and ensure grid stability. UAV-based systems, enhanced with deep learning, have emerged as an efficient alternative to traditional, labor-intensive inspection methods. However, most existing approaches rely on separate models for cable segmentation and anomaly detection, leading to increased computational overhead and reduced reliability in real-time applications. To address these limitations, we propose PowerLine-MTYOLO, a lightweight, one-stage, multitask model designed for simultaneous power cable segmentation and broken strand detection from UAV imagery. Built upon the A-YOLOM architecture, and leveraging the YOLOv8 foundation, our model introduces four novel specialized modules—SDPM, HAD, EFR, and the Shape-Aware Wise IoU loss—that improve geometric understanding, structural consistency, and bounding-box precision. We also present the Merged Public Power Cable Dataset (MPCD), a diverse, open-source dataset tailored for multitask training and evaluation. The experimental results show that our model achieves up to +10.68% mAP@50 and +1.7% IoU compared to A-YOLOM, while also outperforming recent YOLO-based detectors in both accuracy and efficiency. These gains are achieved with a smaller model memory footprint and a similar inference speed compared to A-YOLOM. By unifying detection and segmentation into a single framework, PowerLine-MTYOLO offers a promising solution for autonomous aerial inspection and lays the groundwork for future advances in fine-structure monitoring tasks. Full article
Show Figures

Figure 1

11 pages, 3334 KiB  
Article
Research on 10 kV Cable Insulation Detection Method Based on Ground Current Phase Variation
by Gang Liu, Yuanming Zhang, Tonghui Ye, Dongdong Zhang, Peigen Cao and Yulan Che
Energies 2025, 18(13), 3586; https://doi.org/10.3390/en18133586 - 7 Jul 2025
Viewed by 334
Abstract
In view of the limitations of traditional offline detection and external excitation online detection of 10 kV cables, this paper proposes a method to evaluate the insulation aging condition of power cables by online measuring of the phase angle of the cable’s ground [...] Read more.
In view of the limitations of traditional offline detection and external excitation online detection of 10 kV cables, this paper proposes a method to evaluate the insulation aging condition of power cables by online measuring of the phase angle of the cable’s ground current, and explores the impact of load fluctuations on cable insulation. By setting the relative permittivity of the cable to characterize the phase variation of the ground current under different aging degrees, and analyzing the phase variation of the cable’s ground current under different load changes at the same aging degree, a load correction-based dynamic dielectric loss evaluation method for cables is proposed. Through the construction of cable simulation models and the processing of field data, the following conclusions have been reached: Under a 1 MW load, the phase angle of the sheath grounding current in the aged phase increases as the dielectric constant of the insulation increases. At the same aging degree, with an increase in load, the phase differences of the aging phase sheath ground current and the steel armor ground current both show a decreasing trend. To eliminate the impact of load, a dynamic dielectric loss load correction method is proposed, and combined with field data analysis, the dynamic dielectric loss of cables under different loads is corrected to a 1 MW load. Specifically: Under 0.3 MW, the correction coefficients k for the sheath and steel armor are 0.609 and 0.778, respectively. Under 3.5 MW, the correction coefficients k for the sheath and steel armor are 1.435 and 1.089, respectively. This study provides a theoretical basis and experimental verification for online cable monitoring methods. Full article
(This article belongs to the Special Issue Trends and Challenges in Power System Stability and Control)
Show Figures

Figure 1

14 pages, 1838 KiB  
Article
Cable Aging State Diagnosis Adapted from Frequency-Domain Dielectric Spectroscopy and Polarization–Depolarization Current
by Yingqiang Shang, Yang Zhao, Hongquan Ji, Jingyue Ma, Jiren Chen, Ziheng Li, Kejia Wang and Zepeng Lv
Energies 2025, 18(12), 3169; https://doi.org/10.3390/en18123169 - 17 Jun 2025
Viewed by 425
Abstract
Cross-linked polyethylene (XLPE) cables will gradually experience aging under various stresses during long-term operation, which may lead to faults and seriously affect the safe and stable operation of the power system. This article prepares aged cable samples by accelerating the thermal aging of [...] Read more.
Cross-linked polyethylene (XLPE) cables will gradually experience aging under various stresses during long-term operation, which may lead to faults and seriously affect the safe and stable operation of the power system. This article prepares aged cable samples by accelerating the thermal aging of XLPE cables, and combines frequency-domain dielectric spectroscopy (FDS) and the polarization–depolarization current method (PDC) for detection and analysis. By measuring the dielectric loss of aged cables using frequency-domain dielectric spectroscopy, it was found that the dielectric loss value in the low-frequency region significantly increases with aging time, indicating that aging leads to an increase in polarity groups and polarization loss. The high-frequency dielectric loss also significantly increases with the strengthening of dipole polarization. At the same time, using the polarization–depolarization current method to measure the polarization current and depolarization current of cables, it was found that the stable value of polarization current increases with aging time, further verifying the changes in the conductivity and polarization characteristics of insulation materials. Combining the broadband dielectric response characteristics of FDS (0.001 Hz–1 kHz) with the time-domain charge transfer analysis of PDC, the molecular structure degradation (dipole polarization enhancement) and interface defect accumulation (space charge effect) of cable aging are revealed from both frequency- and time-domain perspectives. The experimental results show that the integral value of the low-frequency region of the frequency-domain dielectric spectrum and the stable value of the polarization depolarization current are positively correlated with the aging time, and can make use of effective indicators to evaluate the aging state of XLPE cables. Full article
Show Figures

Figure 1

22 pages, 3233 KiB  
Article
Improved Firefly Algorithm-Optimized ResNet18 for Partial Discharge Pattern Recognition Within Small-Sample Scenarios
by Yuhai Yao, Jun Gu, Tianle Li, Ying Zhang, Zihao Jia, Qiao Zhao and Jingrui Zhang
Processes 2025, 13(6), 1764; https://doi.org/10.3390/pr13061764 - 3 Jun 2025
Viewed by 455
Abstract
The growing complexity of electrical infrastructure has elevated partial discharge (PD) detection to a crucial methodology for ensuring power system safety. Current PD pattern recognition approaches encounter persistent challenges in low-data scenarios, particularly regarding classification accuracy and model generalizability. This study develops a [...] Read more.
The growing complexity of electrical infrastructure has elevated partial discharge (PD) detection to a crucial methodology for ensuring power system safety. Current PD pattern recognition approaches encounter persistent challenges in low-data scenarios, particularly regarding classification accuracy and model generalizability. This study develops a Firefly Algorithm with a Black Hole Mechanism-ResNet18 (FBH-ResNet18) framework that synergistically integrates the Firefly Algorithm with the Black Hole Mechanism (FBH algorithm) optimization with residual neural networks for PD signal classification using phase-resolved partial discharge (PRPD) mappings. A dedicated experimental platform first acquires PD signals through UHF sensors, which are subsequently converted into two-dimensional PRPD representations. The FBH algorithm systematically optimizes four key hyperparameters within the ResNet18 architecture during network training. The Black Hole Mechanism and improved population dynamics enhance optimization efficiency, resulting in more accurate hyperparameter tuning and improved model performance. Comparative evaluations demonstrate the enhanced performance of this parameter-optimized model against alternative configurations. Experimental results indicate that the improved ResNet18 achieves fast convergence and strong generalization on small-sample datasets, significantly enhancing recognition accuracy. During the first 80 generations of training, the classification accuracy reaches 89.11%, and in the final iteration, the model’s recognition accuracy increases to 92.55%, outperforming other models with accuracies generally below 90%. Additionally, the model shows excellent performance on the test set, with a loss function value of 0.250785, significantly lower than that of other models, indicating superior performance on small sample datasets. This research provides an effective solution for power cable fault diagnosis, offering high practical value. Full article
Show Figures

Figure 1

24 pages, 2174 KiB  
Article
Diode Rectifier-Based Low-Cost Delivery System for Marine Medium Frequency Wind Power Generation
by Tao Xia, Yangtao Zhou, Qifu Zhang, Haitao Liu and Lei Huang
J. Mar. Sci. Eng. 2025, 13(6), 1062; https://doi.org/10.3390/jmse13061062 - 28 May 2025
Viewed by 387
Abstract
Offshore wind power has a broad development prospect, but with the development of offshore wind farms to the deep sea, the traditional high-voltage AC transmission has been difficult to adapt to the offshore wind power transmission distance and transmission capacity needs. A flexible [...] Read more.
Offshore wind power has a broad development prospect, but with the development of offshore wind farms to the deep sea, the traditional high-voltage AC transmission has been difficult to adapt to the offshore wind power transmission distance and transmission capacity needs. A flexible DC transmission system applying modular multilevel converter is a common scheme for offshore wind power, which has been put into use in actual projects, but it is still facing the problems of high cost of offshore converter station platforms and high loss of collector systems. In order to improve the economy and reliability of the medium- and long-distance offshore wind power delivery systems, this paper proposes a diode rectifier-based medium-frequency AC pooling soft-direct low-cost delivery system for medium- and long-distance offshore wind power. Firstly, the mid-frequency equivalent model of the diode converter is established, and the influence of topology and frequency enhancement on the parameters of the main circuit equipment is analysed; then, the distribution parameters and transmission capacity of the mid-frequency cable are calculated based on the finite element modelling of the marine cable, and the transmission losses of the mid-frequency AC pooling system are then calculated, including the collector losses, converter valve losses, and transformer losses, etc. Finally, an economic analysis is carried out based on a specific example, comparing with the Jiangsu Rudong offshore wind power transmission project, in order to verify the economy of the medium-frequency AC flexible and direct transmission system of the medium- and long-distance offshore wind power using diode rectifier technology. Full article
(This article belongs to the Section Marine Energy)
Show Figures

Figure 1

19 pages, 5580 KiB  
Article
Stand-Alone Operation of Multi-Phase Doubly-Fed Induction Generator Supplied by SiC-Based Current Source Converter
by Łukasz Sienkiewicz, Filip Wilczyński and Szymon Racewicz
Energies 2025, 18(11), 2753; https://doi.org/10.3390/en18112753 - 26 May 2025
Cited by 1 | Viewed by 412
Abstract
This paper investigates the performance of a five-phase silicon carbide (SiC)-based current-source converter (CSC) integrated with a Doubly Fed Induction Generator (DFIG) for wind energy applications. The study explores both healthy and faulty operation, focusing on system behavior under transient conditions and various [...] Read more.
This paper investigates the performance of a five-phase silicon carbide (SiC)-based current-source converter (CSC) integrated with a Doubly Fed Induction Generator (DFIG) for wind energy applications. The study explores both healthy and faulty operation, focusing on system behavior under transient conditions and various load scenarios in stand-alone mode. A novel five-phase space vector PWM strategy in dual coordinate planes is introduced, which enables stable control during normal and open-phase fault conditions. Experimental results demonstrate improved stator voltage and current quality, particularly in terms of reduced Total Harmonic Distortion (THD), compared to traditional voltage-source converter-based systems. Furthermore, the system maintains operational stability under a single-phase open fault, despite increased oscillations in stator quantities. The results highlight the potential of five-phase CSC-DFIG systems as a robust and efficient alternative for wind power plants, particularly in configurations involving long cable connections and requiring low generator losses. Future work will focus on enhancing fault-tolerant capabilities and expanding control strategies for improved performance under different operating conditions. Full article
(This article belongs to the Special Issue Modeling, Control and Optimization of Wind Power Systems)
Show Figures

Figure 1

26 pages, 5364 KiB  
Review
A Comprehensive Review of Cable Monitoring Techniques for Nuclear Power Plants
by Allan Ghaforian, Patrick Duggan and Lixuan Lu
Energies 2025, 18(9), 2333; https://doi.org/10.3390/en18092333 - 2 May 2025
Viewed by 854
Abstract
Cables are critical to the safe and reliable operation of nuclear power plants (NPPs) since they are widely used as a connection medium for various safety-critical equipment. According to research data and operational experience (OPEX), cable materials can degrade with time, resulting in [...] Read more.
Cables are critical to the safe and reliable operation of nuclear power plants (NPPs) since they are widely used as a connection medium for various safety-critical equipment. According to research data and operational experience (OPEX), cable materials can degrade with time, resulting in reduced dielectric strength and higher leakage current. Cables may degrade gradually over time under normal service conditions and fail unexpectedly as a result of sudden exposure to harsher environments, such as Secondary Steam Line Breaks (SSLBs), or when required to operate under the severe conditions of a design basis event, such as a Loss-of-Coolant Accident (LOCA). To assess the condition of medium- and low-voltage cables in Canadian nuclear power plants, numerous inspection methods and electrical testing techniques are employed. These techniques include dielectric spectroscopy, polarization/depolarization current analysis, reflectometry, dielectric standby tests, AC partial discharge, and very-low-frequency (VLF) Tan Delta assessments for medium-voltage (MV) cables. While these methods provide precise diagnostic insights, they require cables to be disconnected at both ends and de-energized, posing operational constraints. Consequently, on-line plant cable monitoring has garnered significant interest, particularly for new reactor developments and large-scale NPP refurbishments. This paper provides a comprehensive benchmarking of existing technologies and a state-of-the-art review of modern cable assessment methodologies. It examines commercially available solutions and ongoing research in power testing for low-voltage (LV) and MV cables, with a particular focus on their applicability in nuclear power settings. Full article
(This article belongs to the Section B4: Nuclear Energy)
Show Figures

Figure 1

17 pages, 4038 KiB  
Article
Return on Investment and Sustainability of HVDC Links: Role of Diagnostics, Condition Monitoring, and Material Innovations
by Gian Carlo Montanari and Sukesh Babu Myneni
Sustainability 2025, 17(7), 3079; https://doi.org/10.3390/su17073079 - 31 Mar 2025
Viewed by 433
Abstract
HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of [...] Read more.
HVDC cable systems are becoming an upscaled technical option, compared to AC, because of various factors, including easier interconnections, lower losses, and longer transmission distances. In addition, renewables providing direct DC energy, electrified transportation, and aerospace where DC can be favored because of higher carried specific power all point in the direction of broad future usage of HV and MV DC links. However, contrary to AC, there is little return from on-field installation as regards long-term cable reliability and aging processes. This gap must be covered by intensive research, and contributing to this research is the purpose of this paper. The focus is on key points for HVDC (and MVDC) cable reliability and sustainability, from design modeling able to account for voltage transients and extrinsic aging (such as that caused by partial discharges) to the impact of aging on insulation conductivity (which rules the electric field distribution, thus aging rate). Also, recyclable and nanostructured materials, as well as health conditions, are considered. It is shown how cable design can account for accelerated aging due to voltage transients, as well as for aging-time dependence of conductivity, and how design can be free of extrinsic aging caused by PDs. Algorithms for health condition evaluations, which have additional value in a relatively new technology such as HVDC polymeric cables, are applied to insulation system aging under partial discharges, showing how they can provide an indication of insulation degradation globally or locally (weak spots) and of possible maintenance times. All of this can effectively contribute to reducing the risk of major cable breakdown and damage under operation, which would significantly affect the return on investment (ROI). Full article
Show Figures

Figure 1

19 pages, 2440 KiB  
Article
Mitigating Skin and Proximity Effect in High-Voltage Underground Segmented Cables Through Individually Insulating Conductor Strings
by Soheil Ahmadi, S. H. Khan and K. T. V. Grattan
Energies 2025, 18(7), 1605; https://doi.org/10.3390/en18071605 - 24 Mar 2025
Viewed by 506
Abstract
High-voltage underground cables inevitably experience frequency-dependent electromagnetic (EM) losses, driven primarily by skin and proximity effects. These losses become more severe at higher harmonic frequencies, which are increasingly common in modern power networks. In traditional multi-segment cable designs, uninsulated conductor bundles enable large [...] Read more.
High-voltage underground cables inevitably experience frequency-dependent electromagnetic (EM) losses, driven primarily by skin and proximity effects. These losses become more severe at higher harmonic frequencies, which are increasingly common in modern power networks. In traditional multi-segment cable designs, uninsulated conductor bundles enable large circular eddy current loops that elevate AC resistance and exacerbate both skin and proximity phenomena. This paper investigates the impact of introducing a thin insulating layer between individual conductor strings in a five-segment high-voltage cable model. Two insulation thicknesses, 75 µm and 100 µm, are examined via two-dimensional finite element (FE) harmonic analysis at 0, 50, 150, and 250 Hz. By confining eddy currents to smaller loops within each conductor, the insulating layer achieves up to a 60% reduction in AC losses compared to the baseline uninsulated model, lowering the ratio of AC to DC resistance from about 3.66 down to 1.47–1.49 at 250 Hz. The findings confirm that adding even a modest inter-strand insulation is highly effective at mitigating skin and proximity effects, with only marginal additional benefit from thicker insulation. Such designs offer improved energy efficiency and reduced thermal stress in underground cables, making them attractive for modern power distribution systems where harmonic content is pervasive. Full article
(This article belongs to the Special Issue Applications of Electromagnetism in Energy Efficiency)
Show Figures

Figure 1

23 pages, 2411 KiB  
Review
Review of Explosion Mechanism and Explosion-Proof Measures for High-Voltage Cable Intermediate Joints
by Wei Qiu, Chen Li, Nianqiao Chen, Yuhua Huang, Zhibin Jiang, Jiangjing Cui, Peifeng Wang and Gang Liu
Energies 2025, 18(6), 1552; https://doi.org/10.3390/en18061552 - 20 Mar 2025
Viewed by 815
Abstract
The intermediate joint of high-voltage cables, as a critical component in the power transmission system, plays a direct role in the stable operation of the entire electrical system. In recent years, frequent explosions of intermediate joints in high-voltage cables have led to significant [...] Read more.
The intermediate joint of high-voltage cables, as a critical component in the power transmission system, plays a direct role in the stable operation of the entire electrical system. In recent years, frequent explosions of intermediate joints in high-voltage cables have led to significant economic losses and safety risks. Therefore, studying the explosion mechanisms and explosion prevention measures of high-voltage cable intermediate joints is particularly important. This article provides a systematic review of the explosion mechanisms and explosion prevention measures for high-voltage cable intermediate joints. It begins by introducing the composition of cable systems and the structural features of the 220 kV prefabricated cable joint. Next, the article elaborates on the spatiotemporal evolution process of cable joint explosions. Typically, a cable joint explosion undergoes several stages: partial discharge, arc breakdown, and insulation material decomposition, which ultimately leads to explosion and ignition. Subsequently, the article reviews each of these dynamic stages in detail. Finally, the article discusses the existing explosion prevention measures and their shortcomings, and proposes future directions for the development of explosion prevention measures. This article can provide a theoretical foundation and technical reference for the research on the explosion mechanisms of high-voltage cable joints, as well as for the development of explosion prevention measures. Full article
Show Figures

Figure 1

19 pages, 4257 KiB  
Article
Two-Dimensional vs. Three-Dimensional FE Modeling of Skin and Proximity Effects in Segmented Cables with Parallel Conductors: A Comparative Study
by Soheil Ahmadi, S. H. Khan and K. T. V. Grattan
Appl. Sci. 2025, 15(6), 2981; https://doi.org/10.3390/app15062981 - 10 Mar 2025
Cited by 1 | Viewed by 735
Abstract
This paper investigates the influence of skin and proximity effects on power losses in segmented power cables using finite element (FE) analysis. Two-dimensional (2D) and three-dimensional (3D) FE models are developed to evaluate the AC-to-DC resistance ratio (RAC/RDC [...] Read more.
This paper investigates the influence of skin and proximity effects on power losses in segmented power cables using finite element (FE) analysis. Two-dimensional (2D) and three-dimensional (3D) FE models are developed to evaluate the AC-to-DC resistance ratio (RAC/RDC) in single-, three-, and five-segment cable configurations. Frequencies of 0, 50, 150, and 250 Hz are considered under an infinite lay length (parallel strands) assumption. This study reveals that 2D modeling provides nearly identical RAC/RDC values to 3D, with deviations of less than 0.6% at 50 Hz when no twisting is present. This highlights the computational efficiency of 2D models for certain cable designs without compromising accuracy. Furthermore, this paper examines the mesh refinement and sub-conductor geometry (hexagonal packing) of underground cables under full compression assumption. The results underscore the viability of 2D cross-sectional simulations for multi-segment cables, ensuring accurate loss predictions while saving considerable computational resources. Full article
Show Figures

Figure 1

16 pages, 1534 KiB  
Article
Impact of Twisting on Skin and Proximity Losses in Segmented Underground Cables: A 3D Finite-Element Study
by Soheil Ahmadi, S. H. Khan and K. T. V. Grattan
Appl. Sci. 2025, 15(5), 2814; https://doi.org/10.3390/app15052814 - 5 Mar 2025
Cited by 1 | Viewed by 846
Abstract
This paper presents a comprehensive three-dimensional (3D) finite-element (FE) study of skin and proximity losses in a five-segment, helically twisted underground power cable. Unlike conventional two-dimensional (2D) analyses—which assume parallel conductors and consequently overestimate eddy current losses—our 3D approach accurately captures the effects [...] Read more.
This paper presents a comprehensive three-dimensional (3D) finite-element (FE) study of skin and proximity losses in a five-segment, helically twisted underground power cable. Unlike conventional two-dimensional (2D) analyses—which assume parallel conductors and consequently overestimate eddy current losses—our 3D approach accurately captures the effects of varying lay lengths (λ). Simulations are performed from 0 Hz (DC) to 50 Hz, showing that while the per-unit-length DC resistance remains unaffected by twisting, the AC resistance can increase significantly depending on the pitch. At 50 Hz, the ratio of AC to DC resistance (RAC/RDC) ranges from about 1.32 for very tight twists (λ=0.1m) to nearly 1.72 for gentle pitches (λ=5.0m). Further analysis reveals that short lay lengths enhance magnetic field coupling, improving current distribution and partially mitigating losses. To quantify these findings, an exponential-saturation model is proposed to describe RAC/RDC as a function of lay length, achieving excellent agreement (R20.996) with the 3D FE data. These results underscore the importance of considering full 3D geometry in cable design, offering a practical tool for optimizing both mechanical reliability and electromagnetic performance in high-voltage underground applications. Full article
(This article belongs to the Special Issue Analysis, Modelling and Simulation in Electrical Power Systems)
Show Figures

Figure 1

14 pages, 6091 KiB  
Article
Insulation Aging Evaluation Method of High Voltage Cable Based on Dielectric Loss Characteristics
by Tao Han, Wenhao Li, Zeping Zheng, Yanqing Li, Jia Chu and Chunlin Hao
Energies 2025, 18(5), 1267; https://doi.org/10.3390/en18051267 - 5 Mar 2025
Cited by 1 | Viewed by 969
Abstract
Health assessments of high-voltage power cables are important for stable operations of power grids; however, most current health assessment model parameters lack whole cable test data, making them unable to effectively characterize the insulation aging state of whole cables. In this paper, a [...] Read more.
Health assessments of high-voltage power cables are important for stable operations of power grids; however, most current health assessment model parameters lack whole cable test data, making them unable to effectively characterize the insulation aging state of whole cables. In this paper, a dielectric loss measurement device for high-voltage cables is developed. Using a high-voltage amplifier and high-precision dielectric loss measurement algorithm, the dielectric loss values of whole cables at different aging stages are measured, and the physicochemical and electrical characteristics of XLPE slice samples at each aging stage are analyzed. Through the analysis of high-voltage dielectric loss, crystallinity, carbonyl index, AC breakdown field strength, and elongation at break, aging correlation parameters are determined. The characteristic high voltage frequency domain dielectric response and delamination degree are proposed to characterize the aging state of cable insulation. The correlation between the high voltage frequency domain dielectric characteristics and cable insulation aging state is established. Finally, an assessment method of the insulation aging state of high-voltage cable is developed, providing a reference for the diagnosis and assessment of the insulation state of high-voltage XLPE cable on site. Full article
(This article belongs to the Section F6: High Voltage)
Show Figures

Figure 1

Back to TopTop