Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = Zagan

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 24640 KB  
Article
Between Modesty and Modernity: The Transformations of the Architecture of the Franciscan Church in Zagan Between the Second Half of the Thirteenth Century and the Beginning of the Sixteenth Century
by Andrzej Legendziewicz, Elżbieta Grodzka, Aleksandra Marcinów and Karol Błaszczyk
Arts 2025, 14(1), 11; https://doi.org/10.3390/arts14010011 - 3 Feb 2025
Viewed by 2716
Abstract
The aim of this article is to present the main phases of transformation of the Franciscan church in Zagan. This church is one of the best-preserved mendicant order churches in Central Europe and Silesia. Until now, it has not been the subject of [...] Read more.
The aim of this article is to present the main phases of transformation of the Franciscan church in Zagan. This church is one of the best-preserved mendicant order churches in Central Europe and Silesia. Until now, it has not been the subject of detailed research. Based on the findings, it was possible to identify the oldest church as a model example of the principles described in the Narbonne Constitutions. The late Gothic vaulting introduced during the reconstruction represents avant-garde solutions from the late 15th century. The evolution of the church interior’s forms in Zagan is presented against the backdrop of other churches in Central Europe and Poland. Special attention is given to the uniqueness of the church, which stands out among other conventual churches with its use of diamond and net vaults in the chancel and nave. Full article
(This article belongs to the Section Applied Arts)
Show Figures

Figure 1

22 pages, 5257 KB  
Article
Modbus RTU Protocol Timing Evaluation for Scattered Holding Register Read and ModbusE-Related Implementation
by Vasile Gheorghiță Găitan, Ionel Zagan and Nicoleta Cristina Găitan
Processes 2025, 13(2), 367; https://doi.org/10.3390/pr13020367 - 28 Jan 2025
Cited by 6 | Viewed by 5284
Abstract
In parallel with the development of data transmission in the telecommunications sector to connect peripheral devices, hardware engineers have defined interfaces for independent communication systems. The basic idea of having standardized interfaces for external devices was quickly extended to control and instrumentation equipment, [...] Read more.
In parallel with the development of data transmission in the telecommunications sector to connect peripheral devices, hardware engineers have defined interfaces for independent communication systems. The basic idea of having standardized interfaces for external devices was quickly extended to control and instrumentation equipment, as the real-time characteristic of distributed systems became a challenge in the field. The proposed Modbus Extension (ModbusE) builds on these new techniques introduced in the UART interface, so that the newly introduced extension retains all the characteristics of the Modbus RTU except for the character bit structure. The validation of the ModbusE protocol allowed the proposal of a new communication message structure, a description of Modbus devices, an acquisition cycle to attain a deterministic temporal response behavior and the definition of an architecture for IIoT integration. In this work, practical research is based on data update times in SMARTConvert software when between 1 and 50 registers are accessed. These registers can, in the most favorable case, be at consecutive addresses and can all be read in a single bus query request, or at addresses 1 to 50, or the registers must be read in separate requests. The contributions of this paper are related to highlighting cases where Modbus modules are incorporated, the addressed registers are not consecutive and the Modbus reads 1 or more holding register records and the ModbusE proposal. As these registers must not be on consecutive addresses, it is necessary to make several requests, defining the function of a Modbus acquisition cycle, adapting the equations to the purpose of the tests carried out, measuring the Modbus communication signals and describing the ModbusE communication concept. Full article
Show Figures

Figure 1

23 pages, 3516 KB  
Article
Proposed Modbus Extension Protocol and Real-Time Communication Timing Requirements for Distributed Embedded Systems
by Nicoleta Cristina Găitan, Ionel Zagan and Vasile Gheorghiță Găitan
Technologies 2024, 12(10), 187; https://doi.org/10.3390/technologies12100187 - 2 Oct 2024
Cited by 9 | Viewed by 5931
Abstract
The general evolution of fieldbus systems has been variously affected by both computer electrical engineering and science. First, the main contribution undoubtedly originated from network IT systems, when the Open Systems Interconnection model was presented. This reference model with seven layers was and [...] Read more.
The general evolution of fieldbus systems has been variously affected by both computer electrical engineering and science. First, the main contribution undoubtedly originated from network IT systems, when the Open Systems Interconnection model was presented. This reference model with seven layers was and remains the foundation for the development of numerous advanced communication protocols. In this paper, the conducted research resulted in a major contribution; specifically, it describes the mathematical model for the Modbus protocol and defines the acquisition cycle model that corresponds to incompletely defined protocols in order to provide a timestamp and achieve temporal consistency for proposed Modbus Extension. The derived technical contribution of the authors is to exemplify the functionality of a typical industrial protocol that can be decomposed to improve the performance of data acquisition systems. Research results in this area have significant implications for innovations in industrial automation networking because of increasing distributed installations and Industrial Internet of Things (IIoT) applications. Full article
Show Figures

Figure 1

21 pages, 6487 KB  
Article
BIoT Smart Switch-Embedded System Based on STM32 and Modbus RTU—Concept, Theory of Operation and Implementation
by Ionel Zagan and Vasile Gheorghiță Găitan
Buildings 2024, 14(10), 3076; https://doi.org/10.3390/buildings14103076 - 26 Sep 2024
Cited by 6 | Viewed by 4436
Abstract
Considering human influence and its negative impact on the environment, the world will have to transform the current energy system into a cleaner and more sustainable one. In residential as well as office buildings, there is a demand to minimize electricity consumption, improve [...] Read more.
Considering human influence and its negative impact on the environment, the world will have to transform the current energy system into a cleaner and more sustainable one. In residential as well as office buildings, there is a demand to minimize electricity consumption, improve the automation of electrical appliances and optimize electricity utilization. This paper describes the implementation of a smart switch with extended facilities compared to traditional switches, such as visual indication of evacuation routes in case of fire and acoustic alerts for emergencies. The proposed embedded system implements Modbus RTU serial communication to receive information from a fire alarm-control panel. An extension to the Modbus communication protocol, called Modbus Extended (ModbusE), is also proposed for smart switches and emergency switchboards. The embedded smart switch described in this paper as a scientific and practical contribution in this field, based on a performant microcontroller system, is integrated into the Building Internet of Things (BIoT) concept and uses the innovative ModbusE protocol. The proposed smart lighting system integrates building lighting access control for smart switches and sockets and can be extended to incorporate functionality for smart thermostats, access control and smart sensor-based information acquisition. Full article
Show Figures

Figure 1

22 pages, 6865 KB  
Article
Modbus Extension Server Implementation for BIoT-Enabled Smart Switch Embedded System Device
by Vasile Gheorghiță Găitan and Ionel Zagan
Sensors 2024, 24(2), 475; https://doi.org/10.3390/s24020475 - 12 Jan 2024
Cited by 6 | Viewed by 3011
Abstract
The industrial control and automation sector has invested in the development and standardization of new wireless (WirelessHART, ISA 100.11a, and WIA-PA) and wired (Profibus/Profinet, Modbus, and LonWORK) solutions aimed at automating processes to support standard monitoring and control functions from the perspective of [...] Read more.
The industrial control and automation sector has invested in the development and standardization of new wireless (WirelessHART, ISA 100.11a, and WIA-PA) and wired (Profibus/Profinet, Modbus, and LonWORK) solutions aimed at automating processes to support standard monitoring and control functions from the perspective of addressing critical applications, as well as those integrated within the Building Internet of Things (BIoT) concept. Distributed data acquisition and control systems allow modern installations to monitor and control devices remotely. Various network protocols have been proposed to specify communication formats between a client/gateway and server devices, with Modbus being an example that has been widely implemented in the latest industrial electrical installations. The main contribution made in this paper concerns the completion of the Modbus Extension (ModbusE) specifications for the server station in the classical Modbus communication architecture, as well as their implementation and testing in an STM32F4 kit. A general-purpose control architecture is proposed for BIoT sector, comprising both intelligent touch switches and communication protocols of which the Modbus protocol is used extensively for the monitoring and control part, especially between clients, smart switches, and devices. The specific contributions concern the presentation of a scientific and practical implementation of improved specifications and their integration as software modules on ModbusE protocol server stations. A client station with a VirtualComm USB PC connection is also implemented in the lab to test the operation of the proposed server with specific Modbus applications. Full article
(This article belongs to the Special Issue Advanced IoT Systems in Smart Cities)
Show Figures

Figure 1

19 pages, 3627 KB  
Article
Enhancing the Modbus Communication Protocol to Minimize Acquisition Times Based on an STM32-Embedded Device
by Ionel Zagan and Vasile Gheorghiță Găitan
Mathematics 2022, 10(24), 4686; https://doi.org/10.3390/math10244686 - 10 Dec 2022
Cited by 12 | Viewed by 7328
Abstract
The primary function of a distributed bus is to connect sensors, actuators, and control units that are used for an acquisition process. Application domains, such as industrial monitoring and control systems, manufacturing processes, or building automation, present different requirements that are not exactly [...] Read more.
The primary function of a distributed bus is to connect sensors, actuators, and control units that are used for an acquisition process. Application domains, such as industrial monitoring and control systems, manufacturing processes, or building automation, present different requirements that are not exactly invariable and coherent. Updating data from Modbus-type devices involves updating data through a technique called polling, which involves repeatedly scanning the registers from each device. This paper highlights the performance of Modbus communication, considering scenarios in which distributed devices are integrated and accessed registers are or are not at consecutive addresses. The Modbus protocol allows reading one or more holding-type data registers. If the registers are not at consecutive addresses, multiple requests are required, with implications for the real-time characteristics of the data acquisition system. We studied the data update times within the SMARTConvert application when variable numbers of registers are accessed, and we designed an extension for the Modbus protocol. The major reason Modbus is used in current research is that no assumptions are required about application semantics, and the performance/resource ratio for generic services is excellent. Full article
(This article belongs to the Special Issue Numerical Methods in Real-Time and Embedded Systems)
Show Figures

Figure 1

17 pages, 6762 KB  
Article
Designing a Custom CPU Architecture Based on Hardware RTOS and Dynamic Preemptive Scheduler
by Ionel Zagan and Vasile Gheorghiță Găitan
Mathematics 2022, 10(15), 2637; https://doi.org/10.3390/math10152637 - 27 Jul 2022
Cited by 4 | Viewed by 4712
Abstract
The current trend in real-time operating systems involves executing many tasks using a limited hardware platform. Thus, a single processor system has to execute multiple tasks with different priorities in different real-time system (RTS) work modes. Hardware schedulers can greatly reduce event trigger [...] Read more.
The current trend in real-time operating systems involves executing many tasks using a limited hardware platform. Thus, a single processor system has to execute multiple tasks with different priorities in different real-time system (RTS) work modes. Hardware schedulers can greatly reduce event trigger latency and successfully remove most of the scheduling overhead, providing more computing cycles for applications. In this paper, we present a hardware-accelerated RTOS based on the replication of resources such as program counters, general purpose registers (GPRs) and pipeline registers. The implementation of this new concept, based on real-time event handling implemented in hardware, is intended to meet the current rigorous requirements imposed by critical real-time systems. The most important attribute of this FPGA implementation is the time required for task context switching, which is only one clock cycle or three clock cycles when working with the atomic instructions used in the case of inter-task synchronization and communication mechanisms. The main contribution of this article is its focus on mutexes and the speed of response associated with related events. Thus, fast switching between threads is also validated, considering the handling of events in the hardware using HW_nMPRA_RTOS (HW-RTOS). The proposed architecture implements inter-task synchronization and communication mechanisms with high performance, improving the overall response time when the mutex or message is expected to relate to a higher-priority task. Full article
(This article belongs to the Special Issue Numerical Methods in Real-Time and Embedded Systems)
Show Figures

Figure 1

31 pages, 7260 KB  
Article
An Overview of the nMPRA and nHSE Microarchitectures for Real-Time Applications
by Vasile Gheorghiță Găitan and Ionel Zagan
Sensors 2021, 21(13), 4500; https://doi.org/10.3390/s21134500 - 30 Jun 2021
Cited by 5 | Viewed by 3265
Abstract
In the context of real-time control systems, it has become possible to obtain temporal resolutions of microseconds due to the development of embedded systems and the Internet of Things (IoT), the optimization of the use of processor hardware, and the improvement of architectures [...] Read more.
In the context of real-time control systems, it has become possible to obtain temporal resolutions of microseconds due to the development of embedded systems and the Internet of Things (IoT), the optimization of the use of processor hardware, and the improvement of architectures and real-time operating systems (RTOSs). All of these factors, together with current technological developments, have led to efficient central processing unit (CPU) time usage, guaranteeing both the predictability of thread execution and the satisfaction of the timing constraints required by real-time systems (RTSs). This is mainly due to time sharing in embedded RTSs and the pseudo-parallel execution of tasks in single-processor and multi-processor systems. The non-deterministic behavior triggered by asynchronous external interrupts and events in general is due to the fact that, for most commercial RTOSs, the execution of the same instruction ends in a variable number of cycles, primarily due to hazards. The software implementation of RTOS-specific mechanisms may lead to significant delays that can affect deadline requirements for some RTSs. The main objective of this paper was the design and deployment of innovative solutions to improve the performance of RTOSs by implementing their functions in hardware. The obtained architectures are intended to provide feasible scheduling, even if the total CPU utilization is close to the maximum limit. The contributions made by the authors will be followed by the validation of a high-performing microarchitecture, which is expected to allow a thread context switching time and event response time of only one clock cycle each. The main purpose of the research presented in this paper is to improve these factors of RTSs, as well as the implementation of the hardware structure used for the static and dynamic scheduling of tasks, for RTOS mechanisms specific to resource sharing and intertask communication. Full article
(This article belongs to the Special Issue Sensors and Real Time Systems for IIoT)
Show Figures

Figure 1

23 pages, 4359 KB  
Article
Experimental Implementation and Performance Evaluation of an IoT Access Gateway for the Modbus Extension
by Vasile Gheorghiță Găitan and Ionel Zagan
Sensors 2021, 21(1), 246; https://doi.org/10.3390/s21010246 - 1 Jan 2021
Cited by 20 | Viewed by 7091
Abstract
This paper presents the relevant aspects regarding the experimental implementation and performance evaluation of an Internet of things (IoT) gateway for the Modbus extension. The proposed Modbus extension specifications are extended by defining the new optimized message format, and the structure of the [...] Read more.
This paper presents the relevant aspects regarding the experimental implementation and performance evaluation of an Internet of things (IoT) gateway for the Modbus extension. The proposed Modbus extension specifications are extended by defining the new optimized message format, and the structure of the acquisition cycle for obtaining a deterministic temporal behavior and solutions are presented for the description of devices at the MODBUS protocol level. Three different implementations are presented, and the Modbus extension’s performance is validated regarding the efficiency in the use of the acquisition cycle time. The software and hardware processing time and the importance and effect of the various components are analyzed and evaluated. They all support the implementation of an Internet of things gateway for Modbus extension. This paper introduces solutions for the structure of the acquisition cycle to include other valuable extensions, discusses the performance of a real implementation in the form of a gateway, adds new features to the Modbus extension specification, and strengthens some of the existing ones. In accordance with the novelty and contribution of this paper to the field of local industrial networks, the results obtained in the analysis, testing, and validation of the Modbus extension protocol refer to the extending of the Modbus functions for industrial process monitoring and control management. Full article
(This article belongs to the Special Issue Sensors and Real Time Systems for IIoT)
Show Figures

Figure 1

18 pages, 2932 KB  
Article
Design, Fabrication, and Testing of an IoT Healthcare Cardiac Monitoring Device
by Ionel Zagan, Vasile Gheorghiță Găitan, Adrian-Ioan Petrariu, Nicolai Iuga and Adrian Brezulianu
Computers 2020, 9(1), 15; https://doi.org/10.3390/computers9010015 - 27 Feb 2020
Cited by 20 | Viewed by 7920
Abstract
The expansion of the concept of the Internet of Things (IoT), together with wireless sensor networks, has given rise to a wide range of IoT applications. This paper presents and describes the concept, theory of operation, and practical results of a Telecare-ECG (Electrocardiogram) [...] Read more.
The expansion of the concept of the Internet of Things (IoT), together with wireless sensor networks, has given rise to a wide range of IoT applications. This paper presents and describes the concept, theory of operation, and practical results of a Telecare-ECG (Electrocardiogram) Monitoring device, designed for the remote monitoring of out-of-hospital cardiac patients. ECG monitoring using the Telecare-ECG Monitor system ensures a better quality of life for patients and greater possibilities for the real-time monitoring and signaling of sporadic cardiac events, by recording instantaneous cardiac arrhythmias captured during certain activities or in the daily environment of the patient; furthermore, hospital resources are less impacted by this device than other devices. In accordance with the novelty and contribution of this paper to the field of ECG investigations, the results obtained in the analysis, testing, and validation of the Telecare-ECG Monitor system refer to the optimization of the functionality of the mobile ECG device under conditions that were as similar to reality as possible. Full article
Show Figures

Figure 1

21 pages, 3583 KB  
Article
Hardware RTOS: Custom Scheduler Implementation Based on Multiple Pipeline Registers and MIPS32 Architecture
by Ionel Zagan and Vasile Gheorghiță Găitan
Electronics 2019, 8(2), 211; https://doi.org/10.3390/electronics8020211 - 14 Feb 2019
Cited by 11 | Viewed by 6435
Abstract
The task context switch operation, the inter-task synchronization and communication mechanisms, as well as the jitter occurred in treating aperiodic events, are crucial factors in implementing real-time operating systems (RTOS). In practice and literature, several solutions can be identified for improving the response [...] Read more.
The task context switch operation, the inter-task synchronization and communication mechanisms, as well as the jitter occurred in treating aperiodic events, are crucial factors in implementing real-time operating systems (RTOS). In practice and literature, several solutions can be identified for improving the response speed and performance of real-time systems. Software implementations of RTOS-specific functions can generate significant delays, adversely affecting the deadlines required for certain applications. This paper presents an original implementation of a dedicated processor, based on multiple pipeline registers, and a hardware support for a dynamic scheduler with the following characteristics: performs unitary event management, provides access to architecture shared resources, prioritizes and executes the multiple events expected by the same task. The paper also presents a method through which interrupts are assigned to tasks. Through dedicated instructions, the integrated hardware scheduler implements tasks synchronization with multiple prioritized events, thus ensuring an efficient functioning of the processor in the context of real-time control. Full article
(This article belongs to the Special Issue New Applications and Architectures Based on FPGA/SoC)
Show Figures

Figure 1

Back to TopTop