Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (14)

Search Parameters:
Keywords = Legionella anisa

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2878 KiB  
Article
The Contribution of Legionella anisa to Legionella Contamination of Water in the Built Environment
by Brian Crook, Charlotte Young, Ceri Rideout and Duncan Smith
Int. J. Environ. Res. Public Health 2024, 21(8), 1101; https://doi.org/10.3390/ijerph21081101 - 20 Aug 2024
Cited by 3 | Viewed by 2787
Abstract
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic, but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonizes water [...] Read more.
Legionella bacteria can proliferate in poorly maintained water systems, posing risks to users. All Legionella species are potentially pathogenic, but Legionella pneumophila (L. pneumophila) is usually the primary focus of testing. However, Legionella anisa (L. anisa) also colonizes water distribution systems, is frequently found with L. pneumophila, and could be a good indicator for increased risk of nosocomial infection. Anonymized data from three commercial Legionella testing laboratories afforded an analysis of 565,750 water samples. The data covered July 2019 to August 2021, including the COVID-19 pandemic. The results confirmed that L. anisa commonly colonizes water distribution systems, being the most frequently identified non-L. pneumophila species. The proportions of L. anisa and L. pneumophila generally remained similar, but increases in L. pneumophila during COVID-19 lockdown suggest static water supplies might favor its growth. Disinfection of hospital water systems was effective, but re-colonization did occur, appearing to favor L. pneumophila; however, L. anisa colony numbers also increased as a proportion of the total. While L. pneumophila remains the main species of concern as a risk to human health, L. anisa’s role should not be underestimated, either as a potential infection risk or as an indicator of the need to intervene to control Legionella’s colonization of water supplies. Full article
Show Figures

Figure 1

24 pages, 15946 KiB  
Article
Characterization of a Novel Species of Legionella Isolated from a Healthcare Facility: Legionella resiliens sp. nov
by Sandra Cristino, Maria Rosaria Pascale, Federica Marino, Carlo Derelitto, Silvano Salaris, Massimiliano Orsini, Stefano Squarzoni, Antonella Grottola and Luna Girolamini
Pathogens 2024, 13(3), 250; https://doi.org/10.3390/pathogens13030250 - 14 Mar 2024
Cited by 4 | Viewed by 3289
Abstract
Two Legionella-like isolates, 8cVS16T and 9fVS26, were isolated from a water distribution system (WDS) in a healthcare facility. Cells were Gram- and Ziehl Neelsen-stain-negative, rod-shaped, motile, and exhibited a blue-white fluorescence under Wood’s lamp at 365 nm. The strains grew in [...] Read more.
Two Legionella-like isolates, 8cVS16T and 9fVS26, were isolated from a water distribution system (WDS) in a healthcare facility. Cells were Gram- and Ziehl Neelsen-stain-negative, rod-shaped, motile, and exhibited a blue-white fluorescence under Wood’s lamp at 365 nm. The strains grew in a range of 32–37 °C on BCYE with L-cysteine (Cys+), GVPC, and MWY agar medium, with a positive reaction for oxidase, catalase, and gelatinase. The dominant fatty acids were summed features 3 (C16:1ω7c/C16:1ω6c) (27.7%), C16:0 iso (17.5%), and C16:0 (16.3%), and Q13 as the major ubiquinone. The mip and rpoB gene sequences showed a similarity of 96.7% and 92.4%, with L. anisa (ATCC 35292T). The whole genomes sequencing (WGS) performed displayed a GC content of 38.21 mol% for both. The digital DNA-DNA hybridization (dDDH) analysis demonstrated the separation of the two strains from the phylogenetically most related L. anisa (ATCC 35292T), with ≤43% DNA-DNA relatedness. The Average Nucleotide Identity (ANI) between the two strains and L. anisa (ATCC 35292T) was 90.74%, confirming that the two isolates represent a novel species of the genus Legionella. The name proposed for this species is Legionella resiliens sp. nov., with 8cVS16T (=DSM 114356T = CCUG 76627T) as the type strain. Full article
(This article belongs to the Special Issue Bacterial Biofilm, Genomics and Virulence)
Show Figures

Graphical abstract

16 pages, 3205 KiB  
Article
Polyethersulfone (PES) Filters Improve the Recovery of Legionella spp. and Enhance Selectivity against Interfering Microorganisms in Water Samples
by Pablo Casino, Asunción López, Sara Peiró, Santiago Rios, Aldous Porta, Gemma Agustí, Daniela Terlevich, Daniel Asensio, Ana María Marqués and Núria Piqué
Polymers 2023, 15(12), 2670; https://doi.org/10.3390/polym15122670 - 13 Jun 2023
Cited by 2 | Viewed by 2374
Abstract
In the analysis of water samples, the type of filtration membrane material can influence the recovery of Legionella species, although this issue has been poorly investigated. Filtration membranes (0.45 µm) from different materials and manufacturers (numbered as 1, 2, 3, 4, and 5) [...] Read more.
In the analysis of water samples, the type of filtration membrane material can influence the recovery of Legionella species, although this issue has been poorly investigated. Filtration membranes (0.45 µm) from different materials and manufacturers (numbered as 1, 2, 3, 4, and 5) were compared: mixed cellulose esters (MCEs), nitrocellulose (NC), and polyethersulfone (PES). After membrane filtration of samples, filters were placed directly onto GVPC agar and incubated at 36 ± 2 °C. The highest mean counts of colony-forming units and colony sizes for Legionella pneumophila and Legionella anisa were obtained with PES filters (p < 0.001). All membranes placed on GVPC agar totally inhibited Escherichia coli and Enterococcus faecalis ATCC 19443 and ATCC 29212, whereas only the PES filter from manufacturer 3 (3-PES) totally inhibited Pseudomonas aeruginosa. PES membrane performance also differed according to the manufacturer, with 3-PES providing the best productivity and selectivity. In real water samples, 3-PES also produced a higher Legionella recovery and better inhibition of interfering microorganisms. These results support the use of PES membranes in methods where the filter is placed directly on the culture media and not only in procedures where membrane filtration is followed by a washing step (according to ISO 11731:2017). Full article
(This article belongs to the Special Issue Advanced Polymer for Membrane Applications)
Show Figures

Figure 1

13 pages, 3110 KiB  
Article
Impact of Chlorine Dioxide on Pathogenic Waterborne Microorganisms Occurring in Dental Chair Units
by Theresa Isabella Maria Krüger, Susann Herzog, Alexander Mellmann and Thorsten Kuczius
Microorganisms 2023, 11(5), 1123; https://doi.org/10.3390/microorganisms11051123 - 26 Apr 2023
Cited by 7 | Viewed by 2448
Abstract
Bacterial contamination is a problem in dental unit water lines with the consequence of implementing regular disinfection. In this study, the short-term impact of chlorine dioxide (ClO2) treatment was investigated on the microorganisms Legionella pneumophila and L. anisa, Pseudomonas aeruginosa [...] Read more.
Bacterial contamination is a problem in dental unit water lines with the consequence of implementing regular disinfection. In this study, the short-term impact of chlorine dioxide (ClO2) treatment was investigated on the microorganisms Legionella pneumophila and L. anisa, Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus. The environmental background was proven as an important factor regarding the tolerance to 0.4 mg/L ClO2 as saline and phosphate-buffered saline resulted in a higher bacterial reduction than tap water. Gram-positive microorganisms demonstrated higher robustness to ClO2 than Gram-negative, and microorganisms adapted to tap water showed increased stability compared to cultured cells. At high densities, substantial numbers of bacteria were able to withstand disinfection, whereby the use of 4.6 mg/L ClO2 increased the inactivation rate. A massive cell decrease occurred within the first 5 minutes with subsequent plateau formation or slowed cell reduction upon further exposure. This biphasic kinetics cannot be explained by a ClO2 depletion effect alone, because the probability of bacterial subpopulations with increased tolerance should be taken into account, too. Our results prove high disinfection efficiency to microorganisms that were rather found in correlation to the level of bacterial contamination and background solutions than the chosen concentration for ClO2 treatment itself. Full article
(This article belongs to the Section Public Health Microbiology)
Show Figures

Figure 1

9 pages, 780 KiB  
Article
Four-Year Environmental Surveillance Program of Legionella spp. in One of Palermo’s Largest Hospitals
by Ignazio Arrigo, Elena Galia, Teresa Fasciana, Orazia Diquattro, Maria Rita Tricoli, Nicola Serra, Mario Palermo and Anna Giammanco
Microorganisms 2022, 10(4), 764; https://doi.org/10.3390/microorganisms10040764 - 1 Apr 2022
Cited by 14 | Viewed by 3177
Abstract
Legionella is a ubiquitous bacterium that lives in freshwater environments and colonizes human-made water systems. Legionella pneumophila is the most virulent species, and risk factors for Legionnaires’ disease include increasing age, smoking, chronic diseases, and immunodeficiency. For this reason, it is very important [...] Read more.
Legionella is a ubiquitous bacterium that lives in freshwater environments and colonizes human-made water systems. Legionella pneumophila is the most virulent species, and risk factors for Legionnaires’ disease include increasing age, smoking, chronic diseases, and immunodeficiency. For this reason, it is very important to assess and monitor hospital water systems in order to prevent legionellosis. We have monitored a large hospital in Palermo for four years. To determine the presence of microorganisms, according to national guidelines, we used the culture method, which is considered the gold standard for Legionella detection. Sampling was divided into five macro-areas, and a total of 251 samples were collected during the period of investigation, 49% of which were Legionella spp.-positive and 51% were Legionella spp.-negative. Positive samples with L. pneumophila. sgr 2-15 were most frequent in the Underground (55.6%, p = 0.0184), Medicine (42.9%, p = 0.0184) and Other (63.2%, p = 0.002) areas; while positive samples for L. pneumophila sgr 1 were less frequent in the Underground (0.0%, p = 0.0184) and Surgery areas (4.5%, p = 0.033), and for Legionella anisa, were less frequent in the Medicine (4.1%, p = 0.021), Oncohematology (0.0%, p = 0.0282), and Other (0.0%, p = 0.016) areas. Finally, no significant differences were observed among the areas for each isolate considered. The surveillance carried out in these years demonstrates the importance of monitoring, which allows us to analyze the conditions of hospital facilities and, therefore, prevent Legionella spp. infections. Full article
(This article belongs to the Special Issue Legionella pneumophila: A Microorganism with a Thousand Faces)
Show Figures

Figure 1

16 pages, 605 KiB  
Article
Water Age Effects on the Occurrence and Concentration of Legionella Species in the Distribution System, Premise Plumbing, and the Cooling Towers
by Alshae R. Logan-Jackson and Joan B. Rose
Microorganisms 2022, 10(1), 81; https://doi.org/10.3390/microorganisms10010081 - 31 Dec 2021
Cited by 20 | Viewed by 4766
Abstract
In this study, droplet digital PCRTM (ddPCRTM) was used to characterize total Legionella spp. and five specific Legionella species from source (groundwater) to exposure sites (taps and cooling towers). A total of 42–10 L volume water samples were analyzed during [...] Read more.
In this study, droplet digital PCRTM (ddPCRTM) was used to characterize total Legionella spp. and five specific Legionella species from source (groundwater) to exposure sites (taps and cooling towers). A total of 42–10 L volume water samples were analyzed during this study: 12 from a reservoir (untreated groundwater and treated water storage tanks), 24 from two buildings (influents and taps), and six from cooling towers, all part of the same water system. The approximate water age (time in the system) for all sample locations are as follows: ~4.5, 3.4, 9.2, 20.8, and 23.2 h (h) for the groundwater to the reservoir influent, reservoir influent to the reservoir effluent, reservoir effluent to building Fa (building names are abbreviated to protect the privacy of site location), building ERC and the cooling towers, respectively. Results demonstrated that gene copies of Legionella spp. (23S rRNA) were significantly higher in the cooling towers and ERC building (p < 0.05) relative to the reservoir and building Fa (closest to reservoir). Legionella spp. (23S rRNA) were found in 100% (42/42) of water samples at concentrations ranging from 2.2 to 4.5 Log10 GC/100 mL. More specifically, L. pneumophila was found in 57% (24/42) of the water samples, followed by L. bozemanii 52% (22/42), L. longbeachae 36% (15/42), L. micdadei 23% (10/42) and L. anisa 21% (9/42) with geometric mean concentrations of 1.7, 1.7, 1.4, 1.6 and 1.7 Log10 GC/100 mL, respectively. Based on this study, it is hypothesized that water age in the distribution system and the premise-plumbing system as well as building management plays a major role in the increase of Legionella spp., (23S rRNA) and the diversity of pathogenic species found as seen in the influent, and at the taps in the ERC building—where the building water quality was most comparable to the industrial cooling towers. Other pathogenic Legionella species besides L.pneumophila are also likely amplifying in the system; thus, it is important to consider other disease relevant species in the whole water supply system—to subsequently control the growth of pathogenic Legionella in the built water environment. Full article
(This article belongs to the Special Issue Legionella pneumophila: A Microorganism with a Thousand Faces)
Show Figures

Figure 1

15 pages, 1033 KiB  
Article
Cooccurrence of Five Pathogenic Legionella spp. and Two Free-Living Amoebae Species in a Complete Drinking Water System and Cooling Towers
by Alshae Logan-Jackson and Joan B. Rose
Pathogens 2021, 10(11), 1407; https://doi.org/10.3390/pathogens10111407 - 30 Oct 2021
Cited by 11 | Viewed by 4798
Abstract
Pathogenic Legionella species grow optimally inside free-living amoebae to concentrations that increase risks to those who are exposed. The aim of this study was to screen a complete drinking water system and cooling towers for the occurrence of Acanthamoeba spp. and Naegleria fowleri [...] Read more.
Pathogenic Legionella species grow optimally inside free-living amoebae to concentrations that increase risks to those who are exposed. The aim of this study was to screen a complete drinking water system and cooling towers for the occurrence of Acanthamoeba spp. and Naegleria fowleri and their cooccurrence with Legionella pneumophila, Legionella anisa, Legionella micdadei, Legionella bozemanii, and Legionella longbeachae. A total of 42 large-volume water samples, including 12 from the reservoir (water source), 24 from two buildings (influents to the buildings and exposure sites (taps)), and six cooling towers were collected and analyzed using droplet digital PCR (ddPCR). N. fowleri cooccurred with L. micdadei in 76 (32/42) of the water samples. In the building water system, the concentrations of N. fowleri and L. micdadei ranged from 1.5 to 1.6 Log10 gene copies (GC)/100 mL, but the concentrations of species increased in the cooling towers. The data obtained in this study illustrate the ecology of pathogenic Legionella species in taps and cooling towers. Investigating Legionella’s ecology in drinking and industrial waters will hopefully lead to better control of these pathogenic species in drinking water supply systems and cooling towers. Full article
(This article belongs to the Special Issue Water-Borne Pathogens)
Show Figures

Figure 1

12 pages, 4901 KiB  
Article
Intracellular Behaviour of Legionella Non-pneumophila Strains within Three Amoeba Strains, Including Willaertia magna C2c Maky
by Aurélien Croze, Antoine Carlino, Benjamin Quélard, Adeline Saha, Tiphaine Convert, Jean-Baptiste Eberst and Sandrine Demanèche
Pathogens 2021, 10(10), 1350; https://doi.org/10.3390/pathogens10101350 - 19 Oct 2021
Cited by 9 | Viewed by 3310
Abstract
Legionellosis, an often-lethal pneumonia, is generally associated with contamination by Legionella pneumophila. This bacterium can persist in the environment and resist chemical treatment when it is internalized by amoebae. In addition, there is increasing medical proof that other Legionella species can be [...] Read more.
Legionellosis, an often-lethal pneumonia, is generally associated with contamination by Legionella pneumophila. This bacterium can persist in the environment and resist chemical treatment when it is internalized by amoebae. In addition, there is increasing medical proof that other Legionella species can be causative agents of Legionellosis. The objective of this study was to evaluate whether Legionella non-pneumophila (Lnp) strains were able to use the machinery of amoeba to multiply, or whether amoebae were able to limit their proliferation. Seven strains belonging to the species L. longbeachae, L. anisa, L. bozemanae, L. taurinensis, and L. dumoffii were cocultured with three amoebae, Acanthamoeba castellanii, Willaertia magna T5(S)44, and Willaertia magna C2c Maky, at two temperatures, 22 and 37 °C. We found that at 22 °C, all amoebae were able to phagocytose the seven Lnp strains and to avoid intracellular development, except for L. longbeachae, which was able to multiply inside W. magna T5(S)44. At 37 °C, four Lnp strains were able to hijack the machinery of one or two amoebae and to use it to proliferate, but none were able to multiply inside W. magna C2c Maky. Full article
Show Figures

Figure 1

9 pages, 248 KiB  
Article
Legionella spp. Colonization in Water Systems of Hotels Linked with Travel-Associated Legionnaires’ Disease
by Antonios Papadakis, Maria Keramarou, Dimosthenis Chochlakis, Vassilios Sandalakis, Varvara A. Mouchtouri and Anna Psaroulaki
Water 2021, 13(16), 2243; https://doi.org/10.3390/w13162243 - 17 Aug 2021
Cited by 5 | Viewed by 4257
Abstract
Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease, and cases, clusters and outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ [...] Read more.
Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease, and cases, clusters and outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ Disease Surveillance Network, were inspected and tested for Legionella spp. during 2000–2019 by the public health authorities of the island of Crete (Greece). A total of 3311 samples were collected: 1885 (56.93%) from cold water supply systems, 1387 (41.89%) from hot water supply systems, 37 (1.12%) were swab samples and two (0.06%) were soil. Of those, 685 (20.69%), were collected from 83 (62.89%) hotels, testing positive (≥50 CFU/L) for Legionella pneumophila) serogroups 1–10, 12–14 and non-pneumophila species (L. anisa, L. erythra, L. tusconensis, L. taurinensis, L. birminghamensis, L. rubrilucens, L. londiniesis, L. oakridgensis, L. santicrusis, L. brunensis, L. maceacherii). The most frequently isolated L. pneumophila serogroups were 1 (27.92%) and 3 (17.08%). Significantly higher isolation rates were obtained from hot water supply systems (25.96%) versus cold water systems (16.98%) and swab samples (13.51%). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for hot water temperature <55 °C (R.R.: 4.43), chlorine concentrations <0.2 mg/L (R.R.: 2.69), star ratings <4 (R.R.: 1.73) and absence of Water Safety Plan implementation (R.R.: 1.57). Full article
(This article belongs to the Special Issue Water Quality and the Public Health)
17 pages, 836 KiB  
Article
How Molecular Typing Can Support Legionella Environmental Surveillance in Hot Water Distribution Systems: A Hospital Experience
by Luna Girolamini, Silvano Salaris, Jessica Lizzadro, Marta Mazzotta, Maria Rosaria Pascale, Tiziana Pellati and Sandra Cristino
Int. J. Environ. Res. Public Health 2020, 17(22), 8662; https://doi.org/10.3390/ijerph17228662 - 21 Nov 2020
Cited by 6 | Viewed by 3281
Abstract
In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and [...] Read more.
In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates’ relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections. Full article
(This article belongs to the Special Issue Environmental Bacterial Pathogens and Human Health)
Show Figures

Figure 1

21 pages, 794 KiB  
Article
Advances in Legionella Control by a New Formulation of Hydrogen Peroxide and Silver Salts in a Hospital Hot Water Network
by Luna Girolamini, Ada Dormi, Tiziana Pellati, Paolo Somaroli, Davide Montanari, Andrea Costa, Francesca Savelli, Andrea Martelli, Antonella Grottola, Giulia Fregni Serpini and Sandra Cristino
Pathogens 2019, 8(4), 209; https://doi.org/10.3390/pathogens8040209 - 29 Oct 2019
Cited by 19 | Viewed by 4710
Abstract
Legionella surveillance is an important issue in public health, linked to the severity of disease and the difficulty associated with eradicating this bacterium from the water environment. Different treatments are suggested to reduce Legionella risk, however long-term studies of their efficiency are lacking. [...] Read more.
Legionella surveillance is an important issue in public health, linked to the severity of disease and the difficulty associated with eradicating this bacterium from the water environment. Different treatments are suggested to reduce Legionella risk, however long-term studies of their efficiency are lacking. This study focused on the activity of a new formulation of hydrogen peroxide and silver salts, WTP828, in the hospital hot water network (HWN) to contain Legionella contamination during two years of treatment. The effectiveness of WTP828 was tested measuring physical-chemical and microbiological parameters such as Legionella, Pseudomonas aeruginosa (P. aeruginosa), and a heterotopic plate count (HPC) at 36 °C. Legionella isolates were identified by serotyping and genotyping. WTP 828 induced a reduction in Legionella–positive sites (60% to 36%) and contamination levels (2.12 to 1.7 log10 CFU/L), with isolates belonging to L. pneumophila SG1 (ST1 and ST104), L. anisa and L. rubrilucens widely distributed in HWN. No relevant contamination was found for other parameters tested. The long-term effect of WTP828 on Legionella containment suggest the easy and safe application of this disinfectant, that combined with knowledge of building characteristics, an adequate environmental monitoring and risk assessment plan, become the key elements in preventing Legionella contamination and exposure. Full article
(This article belongs to the Special Issue Legionella Contamination in Water Environment)
Show Figures

Graphical abstract

15 pages, 8621 KiB  
Article
Detection of Legionella anisa in Water from Hospital Dental Chair Units and Molecular Characterization by Whole-Genome Sequencing
by Giuseppe Fleres, Natacha Couto, Mariette Lokate, Luc W. M. Van der Sluis, Christophe Ginevra, Sophie Jarraud, Ruud H. Deurenberg, John W. Rossen, Silvia García-Cobos and Alex W. Friedrich
Microorganisms 2018, 6(3), 71; https://doi.org/10.3390/microorganisms6030071 - 18 Jul 2018
Cited by 18 | Viewed by 6747
Abstract
This study aims to assess contamination with Legionella spp. in water from dental chair units (DCUs) of a hospital dental ward and to perform its molecular characterization by whole-genome sequencing (WGS). We collect eight water samples (250 mL) from four DCUs (sink and [...] Read more.
This study aims to assess contamination with Legionella spp. in water from dental chair units (DCUs) of a hospital dental ward and to perform its molecular characterization by whole-genome sequencing (WGS). We collect eight water samples (250 mL) from four DCUs (sink and water-syringe). Samples are tested for the presence of Legionella spp. (CFUs/mL) by culturing according to the Nederland Norm (NEN) 6265. Three DCUs are found positive for Legionella anisa, and four isolates are cultured (sink n = 2, water-syringe n = 1; two isolates from the same chair) with 1 × 102 CFU/mL. Whole-genome multi-locus sequence typing (wgMLST) results indicate that all strains belong to the same cluster with two to four allele differences. Classical culture combined with WGS allows the identification of a unique clone of L. anisa in several DCUs in the same hospital dental ward. This may indicate a common contamination source in the dental unit waterlines, which was fixed by replacing the chairs and main pipeline of the unit. Our results reveal tap water contamination in direct contact with patients and the usefulness of WGS to investigate bacterial molecular epidemiology. Full article
Show Figures

Figure 1

15 pages, 554 KiB  
Article
Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels
by Antonios Papadakis, Dimosthenis Chochlakis, Vassilios Sandalakis, Maria Keramarou, Yannis Tselentis and Anna Psaroulaki
Int. J. Environ. Res. Public Health 2018, 15(4), 598; https://doi.org/10.3390/ijerph15040598 - 26 Mar 2018
Cited by 29 | Viewed by 12697
Abstract
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to [...] Read more.
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000–November 2017, the public health authorities of the Island of Crete (Greece) inspected 119 hotels associated with TALD, as reported through the European Legionnaires’ Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water) and soil. Of those, 67 (12.93%), originating from 43 (35.83%) hotels, tested positive for Legionella (Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species (L. anisa, L. erythra, L. taurinensis, L. birminghamensis, L. rubrilucens). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78), star classification (<4) (R.R.: 4.75) and absence of Water Safety Plan implementation (R.R.: 3.96). High risk (≥104 CFU/L) was estimated for pool showers (16.42%), garden sprinklers (7.46%) and pool water (5.97%). Full article
(This article belongs to the Special Issue Recreational Water Illnesses)
Show Figures

Figure 1

12 pages, 1859 KiB  
Article
Legionella Survey in the Plumbing System of a Sparse Academic Campus: A Case Study at the University of Perugia
by Ermanno Federici, Silvia Meniconi, Elisa Ceci, Elisa Mazzetti, Chiara Casagrande, Elena Montalbani, Stefania Businelli, Tatiana Mariani, Paolo Mugnaioli, Giovanni Cenci and Bruno Brunone
Water 2017, 9(9), 662; https://doi.org/10.3390/w9090662 - 1 Sep 2017
Cited by 3 | Viewed by 4664
Abstract
We have monitored the presence of bacteria belonging to the genus Legionella in the plumbing of buildings at the University of Perugia (Italy). More than 300 water samples were collected from 156 control-point taps in 41 buildings comprised in the eight campuses of [...] Read more.
We have monitored the presence of bacteria belonging to the genus Legionella in the plumbing of buildings at the University of Perugia (Italy). More than 300 water samples were collected from 156 control-point taps in 41 buildings comprised in the eight campuses of the University. Legionella was absent in most samples, while it was found in only 12 buildings (29% of the total). Molecular analysis indicated the presence of L. pneumophila (serogroups 1, 8 and 6–10), L. taurinensis and L. anisa. In only three cases contamination levels were above the limit at which remedial actions are required, according to international guidelines. In two buildings, where the water temperature could be raised and maintained above 60 °C, thermal disinfection was effective in eradicating Legionella. Conversely, in buildings where contaminations were caused by heat exchangers that produced hot water at a maximum temperature of 50 °C, a chemical disinfection with silver hydrogen peroxide was carried out but was effective only in the short term. In this case study, Legionella contaminations and remediation effectiveness strongly depended on the network and heating-system characteristics, indicating how a multidisciplinary approach that integrates microbiological analysis with hydraulic surveys is necessary for an effective definition of Legionella prevention and control strategies. Full article
Show Figures

Figure 1

Back to TopTop