Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = Doppler-free spectroscopy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 8658 KB  
Review
Imaging and Non-Imaging Approaches for the Diagnosis and Monitoring of Necrotizing Enterocolitis—What Lies Ahead?
by Indrani Bhattacharjee, Catalina Le Cacheux, Eric B. Ortigoza, Jonathan Dillman, Sherwin S. Chan and Alain Cuna
Children 2026, 13(6), 787; https://doi.org/10.3390/children13060787 - 5 Jun 2026
Viewed by 621
Abstract
Necrotizing enterocolitis (NEC) remains one of the most serious gastrointestinal emergencies in preterm infants, and imaging plays a central role in diagnosis and clinical management. Historically, evaluation has relied primarily on abdominal radiography, which remains widely available and embedded in established diagnostic frameworks. [...] Read more.
Necrotizing enterocolitis (NEC) remains one of the most serious gastrointestinal emergencies in preterm infants, and imaging plays a central role in diagnosis and clinical management. Historically, evaluation has relied primarily on abdominal radiography, which remains widely available and embedded in established diagnostic frameworks. However, the hallmark radiographic signs of NEC (i.e., pneumatosis intestinalis, portal venous gas, and free air) reflect relatively advanced manifestations of intestinal injury that indicate established mucosal disruption or transmural necrosis. Bowel ultrasound has increasingly complemented radiography by enabling real-time assessment of bowel wall integrity, perfusion, motility, and intra-abdominal fluid, providing physiologic information that may refine clinical interpretation and monitoring of disease progression. Expanding use of neonatologist-performed bowel ultrasound may further improve access to bedside intestinal imaging and facilitate more timely evaluation in neonatal intensive care settings. In parallel, emerging imaging technologies seek to extend the capabilities of conventional imaging by interrogating biologic processes that underlie intestinal injury. Modalities such as contrast-enhanced ultrasound, ultra-high-frequency ultrasound, and photoacoustic imaging offer the potential to characterize bowel microvascular perfusion, tissue oxygenation, and microstructural changes that may precede overt radiographic abnormalities. Complementary physiologic monitoring approaches are also being explored to identify infants at risk before clinical disease develops. Techniques including superior mesenteric artery Doppler, near-infrared spectroscopy, bowel acoustic monitoring, and electrogastrography aim to detect early alterations in intestinal perfusion, oxygenation, and motility. In addition, artificial intelligence applied to imaging and physiologic data may enhance pattern recognition, risk stratification, and clinical decision support. Together, these advances suggest that NEC evaluation is evolving from a paradigm focused on detecting late structural injury toward integrated approaches capable of identifying intestinal vulnerability earlier and monitoring disease more precisely. Full article
(This article belongs to the Special Issue Necrotizing Enterocolitis in Newborns)
Show Figures

Figure 1

14 pages, 609 KB  
Article
Comparison of Electron Compton Scattering with Positron Compton Scattering in Polyethylene
by Maurizio Dapor
Materials 2025, 18(7), 1609; https://doi.org/10.3390/ma18071609 - 2 Apr 2025
Cited by 3 | Viewed by 1159
Abstract
Understanding the interaction of charged particles with polymers is crucial for applications in materials science, radiation physics, and electron spectroscopy. This study investigates the differences in the elastic scattering spectra of electrons and positrons in polyethylene, focusing on the underlying mechanisms that influence [...] Read more.
Understanding the interaction of charged particles with polymers is crucial for applications in materials science, radiation physics, and electron spectroscopy. This study investigates the differences in the elastic scattering spectra of electrons and positrons in polyethylene, focusing on the underlying mechanisms that influence the spectral features. The analysis isolates key factors such as recoil energy, Doppler broadening, and the interplay between elastic and inelastic mean free paths. Using Monte Carlo simulations, we analyze the effects of the elastic and inelastic mean free paths on the intensity of the elastic peaks in an energy range from 1000 eV to 3000 eV. The results show that the elastic peaks are consistently more intense for electrons than for positrons, correlating with the differences in the respective elastic scattering cross sections. In addition, we evaluate the effects of different inelastic mean free path models on spectral variations and compare the simulated data showing how variations in inelastic mean free path values affect the intensity of elastic peaks and the elastic reflection coefficient of polyethylene. The percentage difference in the elastic reflection coefficients of electrons and positrons in polyethylene decreases from 49% to 24% when the incident particle energy increases from 1000 eV to 3000 eV. These findings contribute to a refined understanding of the interactions of electrons and positrons with polymers, improve the accuracy of Monte Carlo simulations, and promote methods for material characterization. Full article
Show Figures

Figure 1

14 pages, 1633 KB  
Article
Impact of Postoperative Norepinephrine Administration on Free Flap Flow
by Denis Ehrl, Svenja Pistek, Clemens Rieder, Michael Irlbeck, Klaus Hofmann-Kiefer, David Braig, Frederic Klein, Philipp Groene, Riccardo E. Giunta and Nicholas Moellhoff
J. Clin. Med. 2024, 13(24), 7816; https://doi.org/10.3390/jcm13247816 - 20 Dec 2024
Cited by 4 | Viewed by 2229
Abstract
Background/Objectives: The perioperative interplay between blood pressure, vasopressors, and macrocirculation is well established. However, in the context of free flap surgery, the potential impact of these factors on microvascular flow remains elusive. The aim was to evaluate the impact of norepinephrine administration on [...] Read more.
Background/Objectives: The perioperative interplay between blood pressure, vasopressors, and macrocirculation is well established. However, in the context of free flap surgery, the potential impact of these factors on microvascular flow remains elusive. The aim was to evaluate the impact of norepinephrine administration on the microcirculation of free flaps. Methods: Postoperative systolic blood pressure (sBP), norepinephrine infusion rates (NIRs), and free flap microcirculation were monitored prospectively and analyzed retrospectively in patients receiving free flap surgery who required postoperative intermediate (IMC) or intensive care (ICU). Blood flow, hemoglobin oxygenation (SO2), and relative hemoglobin levels (rHbs) were measured over a period of 24 hours post-anastomosis by laser-doppler flowmetry and white light spectroscopy using the “Oxygen to See” device (O2C, LEA Medizintechnik, Gießen, Germany). Multivariate analysis was performed to determine the impact of NIR on microvascular flow, adjusting for several confounding factors. Subgroup analysis was conducted by categorizing into three groups based on patients’ postoperative sBP. Results: Flaps were performed in 105 patients with a mean age of 61.46 ± 16.29 years. Postoperatively, an increase in microvascular flow over time was observed across all free flaps, while NIR decreased and sBP maintained stable values. Multivariate analysis revealed that the time post-anastomosis (B = 3.76, p < 0.001), SO2 (B = 0.55, p < 0.001), rHb (B= −0.79, p < 0.001), female gender (B = 29.25, p = 0.02), and no previous radiation therapy (B = 41.21, p = 0.04) had a significant impact on postoperative microvascular flow in free flaps. NIR, sBP, smoking status, old age, and ASA score showed no significant impact on free flap flow. Further, NIR showed no significant impact on microvascular flow in any of the subgroups investigated. Conclusions: These findings support the safety of using norepinephrine for maintaining stable blood pressure without compromising microvascular flow, offering valuable guidance for postoperative management. Full article
(This article belongs to the Special Issue Clinical Advances in Plastic Surgery)
Show Figures

Figure 1

12 pages, 3451 KB  
Article
Surface Microstructure Study on Corona Discharge-Treated Polyethylene Using Positron Annihilation Spectroscopy
by Jingjing Li, Zhiwei Shen, Liuyang Tie, Tianyuan Long, Qiyue Zhong, Xi Chen, Chongshan Yin, Liguo Liufu, Xianhao Huang, Bangyun Xiong, Xibo Li, Chongxiong Duan and Chunqing He
Molecules 2024, 29(17), 4147; https://doi.org/10.3390/molecules29174147 - 31 Aug 2024
Cited by 8 | Viewed by 3226
Abstract
The microstructure and chemical properties of the corona discharge process could provide an effective method for predicting the performance of high-voltage cable insulation materials. In this work, the depth profile of the microstructure and chemical characteristics of corona discharge-treated PE were extensively investigated [...] Read more.
The microstructure and chemical properties of the corona discharge process could provide an effective method for predicting the performance of high-voltage cable insulation materials. In this work, the depth profile of the microstructure and chemical characteristics of corona discharge-treated PE were extensively investigated using Doppler broadening of position annihilation spectroscopy accompanied with positron annihilation lifetime spectroscopy, attenuated total reflectance Fourier transform infrared spectra, Raman spectra and contact angle measurement. By increasing corona discharge duration, the oxygen-containing polar groups, including hydroxyl, carbonyl and ester groups, strongly contribute to the deterioration of hydrophobicity and the enhancement of hydrophilicity. And the mean free volume size, with a broadening distribution, decreases slightly. The line shape S parameter decreases because of the decrease in free volume elements and the appearance of oxygen-containing groups. Also, the thickness of the degradation layer, determined from the S parameter with positron injection depth, increases and diffuses into the PE matrix. A linear S-W plot within the degradation layer of different corona treatment duration samples indicates the defect type does not change. The S parameter decreases and the W parameter increases with an increasing corona duration. Using a slow positron beam, the nondestructive probe can be used to profile the microstructure and chemical environment across the corona discharge damage depth, which is beneficial for investigating the surface and interfacial insulation materials. Full article
(This article belongs to the Special Issue Electroanalysis of Biochemistry and Material Chemistry—2nd Edition)
Show Figures

Figure 1

11 pages, 9431 KB  
Communication
Hydrogen-Induced Microstructure Changes in Zr/Nb Nanoscale Multilayer Structures
by Roman Laptev, Ekaterina Stepanova, Anton Lomygin, Dmitriy Krotkevich, Alexey Sidorin and Oleg Orlov
Metals 2024, 14(4), 452; https://doi.org/10.3390/met14040452 - 12 Apr 2024
Cited by 6 | Viewed by 2542
Abstract
Zr/Nb nanoscale multilayer coatings (NMCs) were studied after hydrogenation in a gaseous environment at 400 °C. The hydrogen distribution and content were determined by pressure and hydrogenation time. Increasing the pressure from 0.2 to 2 MPa resulted in different hydrogen distribution within the [...] Read more.
Zr/Nb nanoscale multilayer coatings (NMCs) were studied after hydrogenation in a gaseous environment at 400 °C. The hydrogen distribution and content were determined by pressure and hydrogenation time. Increasing the pressure from 0.2 to 2 MPa resulted in different hydrogen distribution within the Zr/Nb NMCs, while the concentration remained constant at 0.0150 ± 0.0015 wt. %. The hydrogen concentration increased from 0.0165 ± 0.001 to 0.0370 ± 0.0015 wt. % when the hydrogenation time was extended from 1 to 7 h. The δ-ZrH hydride phase was formed in the Zr layers with Zr crystals reorienting towards the [100] direction. The Nb(110) diffraction reflex shifted towards smaller angles and the interplanar distance in the niobium layers increased, indicating significant lateral compressive stresses. Despite an increase in pressure, the nanohardness and Young’s modulus of the Zr/Nb NMCs remained stable. Increasing the hydrogen concentration to 0.0370 ± 0.0015 wt. % resulted in a 40% increase in nanohardness. At this concentration, the relative values of the Doppler broadening variable energy positron annihilation spectroscopy (S/S0) increased above the initial level, indicating an increase in excess free volume due to hydrogen-induced defects and changes. However, the predominant positron capture center remained intact. The Zr/Nb NMCs with hydrogen content ranging from 0.0150 ± 0.0015 to 0.0180 ± 0.001 wt. % exhibited a decrease in the free volume probed by positrons, as demonstrated by the Doppler broadening variable energy positron annihilation spectroscopy. This was evidenced by opposite changes in S and W (S↓W↑). The microstructural changes are attributed to defect annihilation during hydrogen accumulation near interfaces with the formation of hydrogen–vacancy clusters and hydrides. Full article
(This article belongs to the Special Issue Study of Hydrogen Embrittlement of Metallic Materials)
Show Figures

Figure 1

11 pages, 677 KB  
Article
Stabilizing Frequency of a Diode Laser to a Reference Transition of Molecular Iodine through Modulation Transfer Spectroscopy
by Lakhi Sharma, Atish Roy, Subhasis Panja and Subhadeep De
Atoms 2023, 11(5), 83; https://doi.org/10.3390/atoms11050083 - 12 May 2023
Cited by 3 | Viewed by 3951
Abstract
We report the frequency stabilization of an external cavity diode laser (ECDL) to a reference molecular iodine (I2) transition at 13,531.18 cm−1 (739.03382 nm). Using the Modulation Transfer Spectroscopy (MTS) method for the highly sensitive detection of weak absorption signals, [...] Read more.
We report the frequency stabilization of an external cavity diode laser (ECDL) to a reference molecular iodine (I2) transition at 13,531.18 cm−1 (739.03382 nm). Using the Modulation Transfer Spectroscopy (MTS) method for the highly sensitive detection of weak absorption signals, the Doppler-free absorption peaks of I2 corresponding to the hot band transition R(78) (1–11) are resolved. The ECDL’s frequency is stabilized with respect to one of the lines lying within the reference absorption band. For this, the iodine vapor cell is heated to 450 °C and the corresponding circularly polarized pump and probe beam powers are maintained at 10 mW and 1 mW, respectively, to avoid power broadening. The short (100 ms) and long-term (50 h) linewidths of the frequency stabilized laser are measured to be 0.75(3) MHz and 0.5(2) MHz, respectively, whereas the natural linewidth of the specific I2-transitions lie within a range of tens of MHz. Full article
(This article belongs to the Special Issue Recent Advances in Atomic and Molecular Spectroscopy)
Show Figures

Figure 1

16 pages, 2415 KB  
Article
Immediate Effects of Myofascial Release Treatment on Lumbar Microcirculation: A Randomized, Placebo-Controlled Trial
by Andreas Brandl, Christoph Egner, Rüdiger Reer, Tobias Schmidt and Robert Schleip
J. Clin. Med. 2023, 12(4), 1248; https://doi.org/10.3390/jcm12041248 - 4 Feb 2023
Cited by 36 | Viewed by 14173
Abstract
(1) Background: Inflammatory processes in the thoracolumbar fascia (TLF) lead to thickening, compaction, and fibrosis and are thought to contribute to the development of nonspecific low back pain (nLBP). The blood flow (BF) of fascial tissue may play a critical role in this [...] Read more.
(1) Background: Inflammatory processes in the thoracolumbar fascia (TLF) lead to thickening, compaction, and fibrosis and are thought to contribute to the development of nonspecific low back pain (nLBP). The blood flow (BF) of fascial tissue may play a critical role in this process, as it may promote hypoxia-induced inflammation. The primary objective of the study was to examine the immediate effects of a set of myofascial release (MFR) techniques on the BF of lumbar myofascial tissue. The secondary objectives were to evaluate the influence of TLF morphology (TLFM), physical activity (PA), and body mass index (BMI) on these parameters and their correlations with each other. (2) Methods: This study was a single-blind, randomized, placebo-controlled trial. Thirty pain-free subjects (40.5 ± 14.1 years) were randomly assigned to two groups treated with MFR or a placebo intervention. Correlations between PA, BMI, and TLFM were calculated at baseline. The effects of MFR and TLFM on BF (measured with white light and laser Doppler spectroscopy) were determined. (3) Results: The MFR group had a significant increase in BF after treatment (31.6%) and at follow-up (48.7%) compared with the placebo group. BF was significantly different between disorganized and organized TLFM (p < 0.0001). There were strong correlations between PA (r = −0.648), PA (d = 0.681), BMI (r = −0.798), and TLFM. (4) Conclusions: Impaired blood flow could lead to hypoxia-induced inflammation, possibly resulting in pain and impaired proprioceptive function, thereby likely contributing to the development of nLBP. Fascial restrictions of blood vessels and free nerve endings, which are likely associated with TLFM, could be positively affected by the intervention in this study. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

14 pages, 6656 KB  
Article
Curcumin Loaded Nanocarriers with Varying Charges Augmented with Electroporation Designed for Colon Cancer Therapy
by Julita Kulbacka, Kazimiera A. Wilk, Urszula Bazylińska, Magda Dubińska-Magiera, Stanisław Potoczek and Jolanta Saczko
Int. J. Mol. Sci. 2022, 23(3), 1377; https://doi.org/10.3390/ijms23031377 - 26 Jan 2022
Cited by 16 | Viewed by 4955
Abstract
(1) Background: The size and surface charge are the most significant parameters of nanocarriers that determine their efficiency and potential application. The poor cell uptake of encapsulated drugs is the main limitation in anticancer treatment. The well-defined properties of nanocarriers will enable to [...] Read more.
(1) Background: The size and surface charge are the most significant parameters of nanocarriers that determine their efficiency and potential application. The poor cell uptake of encapsulated drugs is the main limitation in anticancer treatment. The well-defined properties of nanocarriers will enable to target specific tissue and deliver an active cargo. (2) Methods: In the current study, poly(D,L -lactide) (PLA) nanocarriers loaded with curcumin (CUR) and differing surface charge were evaluated for transport efficacy in combination with electroporation (EP) in dependence on the type of cells. The obtained CUR-loaded nanoparticles with diameters ranging from 195 to 334 nm (derived from dynamic light scattering (DLS)) were characterized by atomic force microscopy (AFM) (morphology and shape) and Doppler electrophoresis (ζ-potential) as well as UV-vis spectroscopy (CUR encapsulation efficiency (about 90%) and photobleaching rate). The drug delivery properties of the obtained PLA nanocarriers enhanced by electroporation were assessed in human colon cancer cells (LoVo), excitable normal rat muscle cells (L6), and free of voltage-gated ion channels cells (CHO-K1). CLSM studies, viability, and ROS release were performed to determine the biological effects of nanocarriers. (3) Results: The highest photodynamic activity indicated anionic nanocarriers (1a) stabilized by C12(COONa)2 surfactant. Nanocarriers were cytotoxic for LoVo cells and less cytotoxic for normal cells. ROS release increased in cancer cells with the increasing electric field intensity, irradiation, and time after EP. Muscle L6 cells were less sensitive to electric pulses. (4) Conclusions: EP stimulation for CUR-PLA nanocarriers transport was considered to improve the regulated and more effective delivery of nanosystems differing in surface charge. Full article
Show Figures

Figure 1

18 pages, 2518 KB  
Systematic Review
Near-Infrared Spectroscopy (NIRS) versus Hyperspectral Imaging (HSI) to Detect Flap Failure in Reconstructive Surgery: A Systematic Review
by Anouk A. M. A. Lindelauf, Alexander G. Saelmans, Sander M. J. van Kuijk, René R. W. J. van der Hulst and Rutger M. Schols
Life 2022, 12(1), 65; https://doi.org/10.3390/life12010065 - 3 Jan 2022
Cited by 28 | Viewed by 5112
Abstract
Rapid identification of possible vascular compromise in free flap reconstruction to minimize time to reoperation improves achieving free flap salvage. Subjective clinical assessment, often complemented with handheld Doppler, is the golden standard for flap monitoring; but this lacks consistency and may be variable. [...] Read more.
Rapid identification of possible vascular compromise in free flap reconstruction to minimize time to reoperation improves achieving free flap salvage. Subjective clinical assessment, often complemented with handheld Doppler, is the golden standard for flap monitoring; but this lacks consistency and may be variable. Non-invasive optical methods such as near-infrared spectroscopy (NIRS) and hyperspectral imaging (HSI) could facilitate objective flap monitoring. A systematic review was conducted to compare NIRS with HSI in detecting vascular compromise in reconstructive flap surgery as compared to standard monitoring. A literature search was performed using PubMed and Embase scientific database in August 2021. Studies were selected by two independent reviewers. Sixteen NIRS and five HSI studies were included. In total, 3662 flap procedures were carried out in 1970 patients using NIRS. Simultaneously; 90 flaps were performed in 90 patients using HSI. HSI and NIRS flap survival were 92.5% (95% CI: 83.3–96.8) and 99.2% (95% CI: 97.8–99.7). Statistically significant differences were observed in flap survival (p = 0.02); flaps returned to OR (p = 0.04); salvage rate (p < 0.01) and partial flap loss rate (p < 0.01). However, no statistically significant difference was observed concerning flaps with vascular crisis (p = 0.39). NIRS and HSI have proven to be reliable; accurate and user-friendly monitoring methods. However, based on the currently available literature, no firm conclusions can be drawn concerning non-invasive monitoring technique superiority Full article
(This article belongs to the Special Issue Recent Advances and Applications of Image-Guided Surgery)
Show Figures

Figure 1

14 pages, 2159 KB  
Article
Nano-Porous-Silicon Powder as an Environmental Friend
by Marwa Nabil, Kamal Reyad Mahmoud, Raghda Nomier, El-Maghraby El-Maghraby and Hussien Motaweh
Materials 2021, 14(15), 4252; https://doi.org/10.3390/ma14154252 - 30 Jul 2021
Cited by 4 | Viewed by 3714
Abstract
Nano-porous silicon (NPS) powder synthesis is performed by means of a combination of the ultra-sonication technique and the alkali chemical etching process, starting with a commercial silicon powder. Various characterization techniques {X-ray powder diffraction, transmission electron microscopy, Fourier Transform Infrared spectrum, and positron [...] Read more.
Nano-porous silicon (NPS) powder synthesis is performed by means of a combination of the ultra-sonication technique and the alkali chemical etching process, starting with a commercial silicon powder. Various characterization techniques {X-ray powder diffraction, transmission electron microscopy, Fourier Transform Infrared spectrum, and positron annihilation lifetime spectroscopy} are used for the description of the product’s properties. The NPS product is a new environmentally friendly material used as an adsorbent agent for the acidic azo-dye, Congo red dye. The structural and free volume changes in NPS powder are probed using positron annihilation lifetime (PALS) and positron annihilation Doppler broadening (PADB) techniques. In addition, the mean free volume (VF), as well as fractional free volume (Fv), are also studied via the PALS results. Additionally, the PADB provides a clear relationship between the core and valence electrons changes, and, in addition, the number of defect types present in the synthesized samples. The most effective parameter that affects the dye removal process is the contact time value; the best time for dye removal is 5 min. Additionally, the best value of the CR adsorption capacity by NPS powder is 2665.3 mg/g at 100 mg/L as the initial CR concentration, with an adsorption time of 30 min, without no impact from temperature and pH. So, 5 min is the enough time for the elimination of 82.12% of the 30 mg/L initial concentration of CR. This study expresses the new discovery of a cheap and safe material, in addition to being environmentally friendly, without resorting to any chemical additives or heat treatments. Full article
Show Figures

Figure 1

12 pages, 2508 KB  
Article
Sodium Resonance Wind-Temperature Lidar at PFRR: Initial Observations and Performance
by Jintai Li, Bifford P. Williams, Jennifer H. Alspach and Richard L. Collins
Atmosphere 2020, 11(1), 98; https://doi.org/10.3390/atmos11010098 - 15 Jan 2020
Cited by 7 | Viewed by 4416
Abstract
A narrowband sodium resonance wind-temperature lidar (SRWTL) has been deployed at Poker Flat Research Range, Chatanika, Alaska (PFRR, 65° N, 147° W). Based on the Weber narrowband SRWTL, the PFRR SRWTL transmitter was upgraded with a state-of-the-art solid-state tunable diode laser as the [...] Read more.
A narrowband sodium resonance wind-temperature lidar (SRWTL) has been deployed at Poker Flat Research Range, Chatanika, Alaska (PFRR, 65° N, 147° W). Based on the Weber narrowband SRWTL, the PFRR SRWTL transmitter was upgraded with a state-of-the-art solid-state tunable diode laser as the seed laser. The PFRR SRWTL currently makes simultaneous measurements in the zenith and 20° off-zenith towards the north with two transmitted beams and two telescopes. Initial results for both nighttime and daytime measurements are presented. We review the performance of the PFRR SRWTL in terms of seven previous and currently operating SRWTLs. The transmitted power from the pulsed dye amplifier (PDA) is comparable with other SRWTL systems (900 mW). However, while the efficiency of the seeding and frequency shifting is comparable to other SRWTLs the efficiency of the pumping is lower. The uncertainties of temperature and wind measurements induced by photon noise at the peak of the layer with a 5 min, 1 km resolution are estimated to be ~1 K and 2 m/s for nighttime conditions, and 10 K and 6 m/s for daytime conditions. The relative efficiency of the zenith receiver is comparable to other SRWTLs (90–97%), while the efficiency of the north off-zenith receiver needs further optimization. An upgrade of the PFRR SRWTL to a full three-beam system with zenith, northward and eastward measurements is in progress. Full article
(This article belongs to the Special Issue Advances in Atmospheric Lidar Remote Sensing)
Show Figures

Figure 1

Back to TopTop