Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (39)

Search Parameters:
Keywords = 980 nm diode laser

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 4472 KiB  
Article
Effect of Low-Level Laser Therapy on Periodontal Host Cells and a Seven-Species Periodontitis Model Biofilm
by Selma Dervisbegovic, Susanne Bloch, Vera Maierhofer, Christian Behm, Xiaohui Rausch-Fan, Andreas Moritz, Christina Schäffer and Oleh Andrukhov
Int. J. Mol. Sci. 2025, 26(14), 6803; https://doi.org/10.3390/ijms26146803 - 16 Jul 2025
Viewed by 322
Abstract
Low-level laser therapy (LLLT) is gaining attention as an effective adjunct to non-surgical periodontal treatment. This study evaluates the potential of LLLT to reduce bacterial load in a clinically relevant in vitro subgingival biofilm model and its impact on the inflammatory response. A [...] Read more.
Low-level laser therapy (LLLT) is gaining attention as an effective adjunct to non-surgical periodontal treatment. This study evaluates the potential of LLLT to reduce bacterial load in a clinically relevant in vitro subgingival biofilm model and its impact on the inflammatory response. A subgingival biofilm model consisting of seven bacterial species was established. Primary human gingival fibroblasts (GFs) and periodontal ligament cells (PDLs) were cultured. Both biofilms and host cells were treated with the DenLase Diode Laser (980 nm) under various clinically relevant settings. The composition and structure of the seven-species biofilms were evaluated using quantitative PCR and fluorescence microscopy, respectively. The inflammatory response in host cells was analyzed by measuring the gene and protein expression levels of various inflammatory mediators. Laser treatment at power outputs ranging from 0.3 to 2 W had no significant effect on biofilm composition or architecture. LLLT, particularly at higher power settings, reduced the viability in both GFs and PDLs up to 70%. Gene expression levels of inflammatory mediators were only minimally influenced by laser treatment. However, LLLT significantly decreased the secretion of all examined cytokines. These findings suggest that LLLT with a 980 nm diode laser, under clinically relevant conditions, exerts anti-inflammatory rather than antimicrobial effects. Full article
Show Figures

Figure 1

14 pages, 1172 KiB  
Article
Laser-Mediated Hemostasis for Older Patients Receiving Routine Dental Treatment
by Suwat Tanya, Saengsome Prajaneh, Piyachat Patcharanuchat and Sajee Sattayut
Dent. J. 2025, 13(7), 315; https://doi.org/10.3390/dj13070315 - 11 Jul 2025
Viewed by 296
Abstract
Background/Objective: Laser therapy has gained attention in dental practice to minimize bleeding and enhance blood clot formation. This study aimed to explore the utilization and to compare the clinical efficacy of laser-mediated hemostasis for older patients receiving routine dental treatment. Methods: A prospective [...] Read more.
Background/Objective: Laser therapy has gained attention in dental practice to minimize bleeding and enhance blood clot formation. This study aimed to explore the utilization and to compare the clinical efficacy of laser-mediated hemostasis for older patients receiving routine dental treatment. Methods: A prospective observational study was conducted across research networks between October 2023 and August 2024, involving 60 patients aged 50 years and older (average = 63.35 years) at risk of postoperative bleeding following dental treatments. Additionally, laser therapy for hemostasis was selected and provided among calibrated operators. A single researcher performed data collection. Before statistical analysis, data verification and clinical assessment were conducted by the operators and researcher. A clinical cut-off for hemostasis was set at 5 min. Two diode laser machines were used namely, an 810 nm and dual wavelengths of 635 nm and 980 nm. Results: There were 94 extraction sockets, 28 procedures of scaling and root planing and 18 procedures of minor oral surgery. Combining laser ablating sulcular fiber and photobiomodulation initiating blood clot formation was a preferable hemostatic technique for extraction socket, while photobiomodulation alone was a preferred technique for soft tissue hemostasis (p < 0.001). All operators confirmed that 97.86 percent of bleeding events achieved more rapid hemostasis. 61.43 percent of bleeding events clinically achieved hemostasis within 5 min by using laser-mediated hemostasis alone (p = 0.092). Full recovery of the extraction socket was significantly observed during the 2- to 4-week follow-up period (p = 0.005). No clinical complications were reported. Conclusions: Laser-mediated hemostasis effectively reduced hemostatic duration, prevented postoperative bleeding and promoted wound healing in older patients undergoing routine dental treatment. Full article
(This article belongs to the Special Issue Laser Dentistry: The Current Status and Developments)
Show Figures

Figure 1

16 pages, 3766 KiB  
Article
The Efficacy of Erbium-Ion, Diode, and CO2 Lasers in Debonding Attachments Used During Overlay Orthodontic Treatment and the Risk of Hard Tooth Tissue Damage Compared to Traditional Methods—An In Vitro Study
by Alina Florczak-Matyjek, Anna Nikodem, Julia Kensy, Jacek Matys and Kinga Grzech-Leśniak
Photonics 2025, 12(6), 621; https://doi.org/10.3390/photonics12060621 - 18 Jun 2025
Viewed by 396
Abstract
Objective: This in vitro study evaluated the effectiveness of three laser systems—diode, CO2, and Er:YAG—for debonding composite attachments used in aligner orthodontic therapy. Materials and Methods: Fifty extracted human premolars with composite attachments were divided into five groups (n = [...] Read more.
Objective: This in vitro study evaluated the effectiveness of three laser systems—diode, CO2, and Er:YAG—for debonding composite attachments used in aligner orthodontic therapy. Materials and Methods: Fifty extracted human premolars with composite attachments were divided into five groups (n = 10): control, RT (rotary tools), diode laser (980 nm, irradiance was 4811 W/cm2), CO2 laser (10.6 µm, irradiance 1531 W/cm2), and Er:YAG laser (2940 nm, irradiance 471.7 W/cm2). Shear bond strength (SBS) testing measured debonding forces. Enamel surface changes were evaluated using micro-CT, optical profilometry, and stereomicroscopy. The Adhesive Remnant Index (ARI) assessed residual bonding material. Results: Laser treatment increased enamel roughness (p < 0.05). Er:YAG laser caused the highest roughness (Sa = 2.03 µm) and up to 0.17 mm enamel loss but left minimal adhesive remnants and no fractures. Diode laser preserved surface smoothness with moderate bond weakening. CO2 laser had intermediate effects. RT showed the highest SBS but resulted in greater enamel alteration. SBS was significantly reduced in the laser groups, lowest for Er:YAG (81.7 ± 45.5 MPa vs. control 196.2 ± 75.3 MPa). ARI indicated better adhesive removal in the laser-treated groups, with Er:YAG showing the highest percentage of clean enamel surfaces (67% vs. 25%). Conclusions: Er:YAG demonstrated the best balance between effective debonding and enamel preservation. Diode and CO2 lasers also offer viable alternatives to rotary tools. Further clinical studies are recommended. Full article
(This article belongs to the Special Issue Photonics: 10th Anniversary)
Show Figures

Figure 1

17 pages, 4200 KiB  
Article
Enhancing Endodontic Outcomes with the Synergistic Microbicidal and Activated Root-Cleansing Technique (SMART): A Novel Approach to Root Canal Irrigation
by Max Foroughi, Sara Abolmaali, Hamid Abedi and Theodore Ravenel
Medicina 2025, 61(5), 874; https://doi.org/10.3390/medicina61050874 - 9 May 2025
Viewed by 533
Abstract
Background and Objectives: Successful endodontic treatment requires thorough disinfection and removal of the smear layer to prevent reinfection. However, conventional irrigants like sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) can compromise dentin integrity. This study assessed the efficacy of the Synergistic Microbicidal [...] Read more.
Background and Objectives: Successful endodontic treatment requires thorough disinfection and removal of the smear layer to prevent reinfection. However, conventional irrigants like sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA) can compromise dentin integrity. This study assessed the efficacy of the Synergistic Microbicidal and Ablative Root canal Technique (SMART), which integrates AromaRoot, a biocompatible irrigation solution based on quaternary ammonium compounds, with 980 nm diode laser activation, to enhance bacterial reduction and smear layer removal. Materials and Methods: Sixty extracted single-rooted human teeth were inoculated with Enterococcus faecalis and divided into four treatment groups using NaOCl, AromaRoot, and 980 nm laser, either alone or in combination. Bacterial counts were measured as colony-forming units per milliliter (CFU/mL). For smear layer analysis, 56 extracted teeth were prepared and irrigated using EDTA, AromaRoot, and laser activation, followed by scanning electron microscopy to evaluate dentinal tubule exposure. Data were analyzed using Kruskal–Wallis and ANOVA. Results: The combination of AromaRoot, NaOCl, and laser activation achieved a 99.00% bacterial reduction (from 8082 to 60 CFU/mL, p < 0.001), outperforming NaOCl alone (98.34%, 131 CFU/mL). For smear layer removal, AromaRoot with laser achieved 78.5% open dentinal tubules in the apical third, significantly higher than EDTA alone (64.5%, p < 0.05), though EDTA remained superior in the coronal third (89.0% vs. 81.0%, p > 0.05). Conclusions: The SMART technique significantly improves both disinfection and smear layer removal in root canal therapy, particularly in the apical region. These findings suggest that AromaRoot, especially when laser-activated, may serve as a safe and effective alternative to conventional irrigants, warranting further clinical evaluation. Full article
(This article belongs to the Special Issue New Research on Endodontic Therapy)
Show Figures

Figure 1

17 pages, 3956 KiB  
Article
Minimally Invasive Root Canal Cleaning: Evaluating Supplementary Irrigation Techniques
by Alissa Tiscareño, P. S. Ortolani-Seltenerich, Ana Ramírez-Muñoz, Omar Pérez-Ron, Pedro M. Mendez S, Carmen Leal-Moya, Giulia Malvicini, Gaya C. S. Vieira and Alejandro R. Pérez
Dent. J. 2025, 13(5), 192; https://doi.org/10.3390/dj13050192 - 27 Apr 2025
Viewed by 903
Abstract
Objectives: This study aimed to evaluate the efficacy of cleaning in minimally shaped mesial and oval distal canals of 3D models of mandibular molars, focusing on positive pressure irrigation, wireless and conventional passive ultrasonic irrigation (PUI), and diode laser (DL) at 980 nm. [...] Read more.
Objectives: This study aimed to evaluate the efficacy of cleaning in minimally shaped mesial and oval distal canals of 3D models of mandibular molars, focusing on positive pressure irrigation, wireless and conventional passive ultrasonic irrigation (PUI), and diode laser (DL) at 980 nm. Methods: Forty-four 3D-printed resin models, based on eleven natural mandibular molars (each with mesial and distal canals), were divided into four groups (n = 11 per group) to evaluate different irrigation methods. A total of 22 mesial canals (size 20/.04) and 11 oval distal canals (size 25/.04) were analyzed per group. Each root canal was uniformly filled with an artificial hydrogel to simulate a biofilm mixture. Following this preparation, the specified irrigation techniques were applied to the respective groups. Quantitative evaluations of pre- and post-irrigation images were performed to assess the efficiency of tissue removal along the entire length of the canal and in the apical, middle, and coronal thirds. Results: The findings revealed no significant differences in the initial amount of tissue between the samples, indicating uniform filling. In the apical region of mesial canals, conventional PUI showed the highest cleaning efficiency (14.1% residual tissue), significantly outperforming the other methods (p < 0.05). Cordless PUI and DL also surpassed positive pressure irrigation, leaving 30.4% and 29.3% residual tissue, respectively, compared to 42.2% with positive pressure. In the middle third, all methods tested performed better than needle irrigation (p < 0.05), but there were no significant differences in the coronal third or over the full canal length. Distal oval canals showed no significant differences in cleaning effectiveness among methods. Conclusions: Although no single method was superior regarding the full canal length, supplementary techniques such as PUI and DL offer potential benefits over conventional irrigation methods, particularly in the apical third of the canal. Complementary approaches such as conventional PUI and diode laser at 980 nm showed superior cleaning efficiency, particularly in the apical third. These results suggest their integration could improve the effectiveness of cleaning in minimally instrumented mesial canals. Full article
(This article belongs to the Special Issue Dentistry in the 21st Century: Challenges and Opportunities)
Show Figures

Figure 1

15 pages, 1249 KiB  
Article
The Effect of Low-Level Laser Therapy to Reduce Pain Caused by Orthodontic Separators: A Randomized, Double-Blind Placebo-Controlled, Split-Mouth Study
by Alireza Khandan Dezfully, Márió Gajdács, Aliz Eperke Pató, Krisztina Kárpáti and Melinda Madléna
Dent. J. 2025, 13(5), 181; https://doi.org/10.3390/dj13050181 - 22 Apr 2025
Viewed by 760
Abstract
Background: During the initiation of routine orthodontic treatment with fixed appliances, placing elastic separators (ESs) may lead to the patient experiencing considerable pain. Earlier studies evaluating the effects of low-level laser therapy (LLLT) on reducing pain caused by orthodontic ESs have reported contradictory [...] Read more.
Background: During the initiation of routine orthodontic treatment with fixed appliances, placing elastic separators (ESs) may lead to the patient experiencing considerable pain. Earlier studies evaluating the effects of low-level laser therapy (LLLT) on reducing pain caused by orthodontic ESs have reported contradictory results. The aim of our study was to evaluate the effect of a single application of LLLT on the experience of pain following ES placement. Methods: A double-blind, placebo-controlled randomized controlled trial was performed—with implementation of the split-mouth technique—where n = 33 volunteers (12 male and 21 female; aged between 19 and 36 years) were enrolled. ESs were placed at the mesial and distal surfaces of the first permanent molars in the upper or lower jaws. Jaws were divided into two quadrants; the treatment group received LLLT (using a GaAlAs diode laser, at a 980 nm wavelength, with 100 mW producing 6 J of energy; continuous wave), while the other quadrant served as the placebo side receiving a similar treatment, but without laser irradiation, immediately after separation. A questionnaire with a visual analogue scale (VAS; 0–100) was used for the assessment of pain (spontaneous pain and pain on mastication) scored for each first permanent molar directly after separation and after 6, 24, 48 and 72 h of both laser and placebo treatment application. Results: Mean VAS values were lower, but not significantly different, between the treatment vs. placebo groups for spontaneous pain at either measurement point (p > 0.05). Mean VAS values were significantly lower in the treatment groups for pain on mastication at the 6 (9.29 ± 12.65 vs. 19.07 ± 20.99; p = 0.025), 24 (21.96 ± 21.11 vs. 37.19 ± 26.35; p = 0.012) and 48 h (28.01 ± 21.40 vs. 42.60 ± 26.29; p = 0.016) measurement points. The analgetic effect of LLLT was most effective after 6 h, both in the resting position (−49% decrease) and during mastication (−51% decrease). Conclusions: A single application of LLLT with 6 J of energy may have beneficial effects on reducing the pain caused by orthodontic ESs used at the initiation of treatment with fixed appliances, especially during mastication, after 6–48 h following the separation procedure. Trial registration: clinicaltrials.gov ID NCT06816537 (date of registration: 7 February 2025, retrospectively registered). Full article
Show Figures

Figure 1

12 pages, 2148 KiB  
Article
Assessment of the Efficacy and Safety of a Dual-Wavelength Diode Laser System for the Treatment of Vulvovaginal Atrophy in Women Without a History of Breast Cancer and in Patients with a History of Breast Cancer
by Gaetano Perrini, Silvia Actis, Margherita Giorgi, Francesca Accomasso, Carola Minella, Cristina Fava, Giorgia Bisconte, Giovanni De Rosa, Annamaria Ferrero and Valentina Elisabetta Bounous
J. Clin. Med. 2025, 14(3), 801; https://doi.org/10.3390/jcm14030801 - 26 Jan 2025
Viewed by 1069
Abstract
Background/Objectives: Vaginal laser therapy is a promising treatment for menopausal vulvovaginal atrophy (VVA). This study evaluates the efficacy of a dual-wavelength diode laser (980 + 1470 nm) in treating VVA. Methods: Thirty postmenopausal patients with moderate-to-severe VVA were recruited, and twenty-nine [...] Read more.
Background/Objectives: Vaginal laser therapy is a promising treatment for menopausal vulvovaginal atrophy (VVA). This study evaluates the efficacy of a dual-wavelength diode laser (980 + 1470 nm) in treating VVA. Methods: Thirty postmenopausal patients with moderate-to-severe VVA were recruited, and twenty-nine completed the study. Patients underwent a screening visit (T0); three laser sessions at 4-week intervals (T1, T2, and T3); and a follow-up visit 4 weeks after the last treatment (T4). At T0 and T4, the Schiller test and Vaginal Maturation Index (VMI) were performed; sexual function was assessed through the Female Sexual Function Index (FSFI) and the Female Sexual Distress Scale-Revised (FSDS-R). At each visit, the Vaginal Health Index (VHI) and the Visual Analog Scale (VAS) for dyspareunia were administered. Potential side effects were investigated, and the VAS for the pain associated with the procedure was assessed. Data analysis included the overall group and two subgroups: women with (group A) and without (group B) a history of breast cancer (BC). Results: Significant improvements in the VHI and reduced dyspareunia were observed at T4 compared to T0 in all groups. The improvement was already seen after the first procedure, with further improvement after the other procedures, being persistent at the 1-month follow-up. The Schiller test showed significant improvements from T0 to T4 in all groups. The VMI showed a significant improvement from T0 to T4 in the overall group and group B. The FSFI questionnaires showed a significant improvement in all areas for the whole population, whereas the FDSF-R questionnaire showed an improvement only in the overall group. Procedural pain was low (mean VAS 1.6), and no side effects were reported. Conclusions: The dual-wavelength diode laser is an effective and safe option for the treatment of VVA in patients with and without a history of BC. Full article
(This article belongs to the Section Obstetrics & Gynecology)
Show Figures

Figure 1

22 pages, 5333 KiB  
Article
Surface and Mineral Changes of Primary Enamel after Laser Diode Irradiation and Application of Remineralization Agents: A Comparative In Vitro Study
by Mihaela-Valentina Cîrdei, Mădălin-Marius Margan, Roxana Margan, Alexandra Ban-Cucerzan, Ion Petre, Iosif Hulka, Razvan Mihai Horhat and Darinca Carmen Todea
Children 2024, 11(9), 1069; https://doi.org/10.3390/children11091069 - 30 Aug 2024
Cited by 2 | Viewed by 2273
Abstract
Objectives: The purpose of this study is to evaluate the remineralization potential of primary teeth enamel after being exposed to different laser diode therapies. Methods: Ninety-six vestibular primary teeth enamel samples were divided into eight groups (n = 12) with varying treatments: [...] Read more.
Objectives: The purpose of this study is to evaluate the remineralization potential of primary teeth enamel after being exposed to different laser diode therapies. Methods: Ninety-six vestibular primary teeth enamel samples were divided into eight groups (n = 12) with varying treatments: control (G1), CPP-ACP-fluoride varnish (G2), diode lasers at 980 nm (G3), 808 nm (G4), 450 nm (G5), 980 nm + CPP-ACP-fluoride varnish (G6), 808 nm + CPP-ACP-fluoride varnish (G7), and 450 nm + CPP-ACP-fluoride varnish (G8). Each sample was assessed using a DIAGNOdent® (KaVo Dental, Biberach, Germany), at baseline, post-treatment, and post-pH cycle remineralization. SEM imaging was performed before and after treatment and following the pH cycle. Results: The results indicated that the 980 nm and 808 nm diode lasers, both alone and in combination with CPP-ACP-fluoride varnish, either maintained or increased the calcium (Ca) weight percentage (Wt%) in the enamel. The 980 nm diode laser combined with CPP-ACP-fluoride varnish (G6) showed a significant increase in Ca Wt%, suggesting a strong remineralization effect. Similarly, the 808 nm diode laser alone (G4) also promoted a substantial increase in Ca Wt%. In contrast, the 450 nm diode laser, whether applied alone or in combination with CPP-ACP-fluoride varnish, resulted in a lower Ca Wt% and an increase in phosphorus (P) Wt%. Most groups, except for the CPP-ACP-fluoride varnish alone (G2), demonstrated an increase in P Wt%, indicating a complex interaction between laser therapy and enamel remineralization. Conclusions: The combined use of laser therapy with CPP-ACP-fluoride varnish significantly enhanced the remineralization of temporary teeth enamel. The 980 nm diode laser + CPP-ACP-fluoride varnish showed the most pronounced improvement in remineralization, while the 808 nm diode laser alone also effectively increased calcium solubility. These findings suggest that higher-wavelength diode lasers, particularly when combined with remineralizing agents, can effectively enhance the mineral content of primary teeth and promote enamel remineralization. Full article
(This article belongs to the Special Issue Public Health and Preventive Medicine for Children)
Show Figures

Figure 1

24 pages, 14811 KiB  
Article
A Novel Therapeutic Approach of 980 nm Photobiomodulation Delivered with Flattop Beam Profile in Management of Recurrent Aphthous Stomatitis in Paediatrics and Adolescents—A Case Series with 3-Month Follow-Up
by Reem Hanna, Ioana Cristina Miron and Stefano Benedicenti
J. Clin. Med. 2024, 13(7), 2007; https://doi.org/10.3390/jcm13072007 - 29 Mar 2024
Cited by 3 | Viewed by 2818
Abstract
Background/Objectives: Recurrent aphthous stomatitis (RAS) is one of the most common oral mucosal lesions and a very debilitating lesion, especially in paediatric and adolescent patients. The current pharmacotherapy offers a pain relief but not without side effects, and therefore photobiomodulation (PBM) can [...] Read more.
Background/Objectives: Recurrent aphthous stomatitis (RAS) is one of the most common oral mucosal lesions and a very debilitating lesion, especially in paediatric and adolescent patients. The current pharmacotherapy offers a pain relief but not without side effects, and therefore photobiomodulation (PBM) can be an alternative therapy. To the authors’ best knowledge, no published study has explored the efficacy of λ 980 nm laser PBM in the management of all RAS subtypes in paediatric and adolescent patients, and therefore, this prospective observational clinical study was conducted to bridge this gap by evaluating λ 980 nm laser PBM efficacy in symptomatic RAS management in paediatric and adolescent patients. The objectives were to evaluate (1) pain intensity alleviation; (2) wound healing rate; (3) wound size closure; (4) a complete resolution; (5) evidence of recurrence; and (6) patients’ treatment satisfaction. Methods: The study’s variables were assessed at the following timepoints: T0: pre-treatment; T1: immediately after first PBM session; T2: 5 hours (h) post first PBM session (via telephone call); T3: immediately after second PBM session (three days post first PBM session); T4: three-day follow-up (after complete PBM treatments); T5: two-week follow-up; and T6: three-month follow-up. The following PBM dosimetry and treatment protocols were employed: λ 980 nm; 300 mW; 60 s; 18 J; CW; flattop beam profile of 1 cm2 spot size; 18 J/cm2; and twice-a-week irradiation (72 h interval). Results: At T1, significant immediate pain intensity relief was reported. 33.33% recorded “4” and 66.67% reported “5” on the quantitative numeric pain intensity scale (NPIS), and this continued to improve significantly (83.33%) at T2. All the subjects reported “0” on the NPIS at T3, T4, T5 and T6. There was a significant reduction in the lesion surface area (>50% complete healing) at T3 compared to T0. Complete healing (100%) with no evidence of scarring and lesion recurrence observed at T4, T5 and T6. Very good patients’ satisfaction was reported at all timepoints. Conclusions: This is the first report demonstrating λ980 nm efficacy in all RAS subtype management in paediatric and adolescent patients with a 3-month follow-up, whereby its PBM dosimetry and treatment protocols were effective from scientific and practical standpoints, and hence multicentre RCTs with large data are warranted to validate its reproducibility and to enrich the knowledge of PBM application in all RAS subtypes. Full article
(This article belongs to the Special Issue Current Challenges in Clinical Dentistry)
Show Figures

Graphical abstract

13 pages, 4192 KiB  
Article
Switchable Fiber Ring Laser Sensor for Air Pressure Based on Mach–Zehnder Interferometer
by Adalberto Perez-Guzman, Julian M. Estudillo-Ayala, Daniel Jauregui-Vazquez, Juan C. Hernandez-Garcia, Javier A. Martin-Vela, Tania Lozano-Hernandez, Jose D. Filoteo-Razo, Juan M. Sierra-Hernandez and Roberto Rojas-Laguna
Appl. Sci. 2023, 13(23), 12607; https://doi.org/10.3390/app132312607 - 23 Nov 2023
Viewed by 1500
Abstract
This work shows a study of pressure gas sensing using an optical fiber interferometer inside a gas cell; here, a thin-core fiber modal interferometer (TCFMI) is fabricated using two distinct types of fiber, a single-mode fiber (SMF model 1060XP) and thin-core fiber (TCF [...] Read more.
This work shows a study of pressure gas sensing using an optical fiber interferometer inside a gas cell; here, a thin-core fiber modal interferometer (TCFMI) is fabricated using two distinct types of fiber, a single-mode fiber (SMF model 1060XP) and thin-core fiber (TCF model 460 HP). This interferometric structure is set into a ring fiber laser with an ytterbium-doped fiber (YDF) pumped with a 980 nm laser diode. The TCFMI interference spectrum shows wavelength shifting and amplitude variations as the chamber pressure is altered in the range of 5 to 40 PSI; these changes control the ring fiber laser cavity response linearly and lead to good stability in its wavelength operation in a range of 30 nm. The proposed interferometer operates as a wavelength-selective filter in the fiber ring laser cavity. The single laser emission shows a side mode suppression ratio of 34.17 dB. The fiber ring laser is a reliable alternative for air pressure sensing applications. Full article
Show Figures

Figure 1

10 pages, 1630 KiB  
Article
Effect of Dentin Conditioning with EDTA and Diode Lasers on Expression of Odontoblast-like Cell Markers of Dental Pulp Stem Cells
by Gabriela Martín, Valentín Preve, Kenneth Hargreaves, Anibal Diogenes, Carolina Inostroza, Nicole Saint-Jean and Claudia Brizuela
Dent. J. 2023, 11(9), 210; https://doi.org/10.3390/dj11090210 - 4 Sep 2023
Cited by 3 | Viewed by 3486
Abstract
Regenerative endodontic procedures rely on the delivery of mesenchymal stem cells into the root canal and on the effect of local growth factors from the dentin and blood clot. The aim of this study was to assess the effect of dentin conditioning with [...] Read more.
Regenerative endodontic procedures rely on the delivery of mesenchymal stem cells into the root canal and on the effect of local growth factors from the dentin and blood clot. The aim of this study was to assess the effect of dentin conditioning with ethylenediamine tetraacetic acid (EDTA) and diode lasers with different wavelengths (808 nm and 980 nm) on the expression of odontoblast-like cell markers. Forty dentin cylinders were divided into four groups according to the irrigation protocol: EDTA, EDTA + 808 nm diode laser, EDTA + 980 nm diode laser, and phosphate-buffered saline as the control group. Dental pulp stem cells were seeded into the previously conditioned cylinders and incubated for 14 days. The quantitative real-time polymerase chain reaction was used to evaluate the expression of dentin sialophosphoprotein (DSPP), dentin morphoprotein-1 (DMP-1), and transforming growth factor-beta 1 (TGF-β1). Data analysis was performed using the Kruskal–Wallis test. The activation of EDTA with 980 nm and 808 nm diode lasers resulted in lower DSPP and DMP-1 expression than that for EDTA alone (p < 0.05 and p < 0.01, respectively). The expression of TGF was similar among all groups. The highest level of expression of odontoblast-like differentiation markers was observed with EDTA alone. However, the use of an 808 nm diode laser during EDTA irrigation reduced the expression of odontoblastic differentiation markers. Full article
(This article belongs to the Special Issue Endodontics: From Technique to Regeneration)
Show Figures

Graphical abstract

10 pages, 4268 KiB  
Communication
Photoactive Properties of Transport Sol-Gel Layers Based on Strontium Titanate for Perovskite Solar Cells
by Alina V. Semchenko, Gagik Y. Ayvazyan, Viktoriya V. Malyutina-Bronskaya, Sergei A. Khakhomov, Dmitry L. Kovalenko, Andrei A. Boiko, Vitali V. Sidski, Anton V. Nestsiaronak, Alexander A. Mayevsky, Konstantin D. Danilchenko, Dmitry V. Zhigulin, Vladimir A. Pilipenko, R. Subasri and Nikolai V. Gaponenko
Photonics 2023, 10(7), 845; https://doi.org/10.3390/photonics10070845 - 21 Jul 2023
Cited by 4 | Viewed by 2038
Abstract
In this work, we have investigated the photocurrent and spectral sensitivity of the silicon/SrTiO3:xNb/perovskite structures. The sol–gel method carried out the deposition of undoped SrTiO3 layers as well as niobium-doped (SrTiO3:Nb) layers at atomic concentrations of 3 and [...] Read more.
In this work, we have investigated the photocurrent and spectral sensitivity of the silicon/SrTiO3:xNb/perovskite structures. The sol–gel method carried out the deposition of undoped SrTiO3 layers as well as niobium-doped (SrTiO3:Nb) layers at atomic concentrations of 3 and 6% Nb. The perovskite layer, CH3NH3PbI3−xClx, has been deposited by the vacuum co-evaporation technique. The layers have been characterized by scanning electron microscopy and X-ray diffraction measurements. The volt–ampere characteristics and spectral sensitivity of the fabricated samples have been measured under illumination with selective wavelengths of 405, 450, 520, 660, 780, 808, 905, 980, and 1064 nm of laser diodes. We have shown that for different configurations of applied voltage between silicon, SrTiO3:xNb, and CH3NH3PbI3−xClx, the structures are photosensitive ones with a variation of photocurrent from microamperes to milliamperes depending on Nb concentration in SrTiO3, and the highest photocurrent and spectral sensitivity values are observed when a SrTiO3:Nb layer with 3 at.% of Nb is used. A possible application of the proposed structure with a SrTiO3:Nb layer for perovskite solar cells and photodetectors is being discussed. Full article
Show Figures

Figure 1

14 pages, 869 KiB  
Article
Success Rate of Direct Pulp Capping with Conventional Procedures Using Ca (OH)2 and Bioactive Tricalcium Silicate Paste vs. Laser-Assisted Procedures (Diode 980 nm, CO2, and Er: YAG)
by Samir Nammour, Marwan El Mobadder, Melanie Namour, Saad Houeis, Daniel Heysselaer, Paul Nahas, Carmen D. Todea, Jacek Matys, Kinga Grzech-Leśniak, Aneta Olszewska, Wassim El Mobadder, Ilaria Giovannacci, Markus Laky, Amaury Namour and Sabine Geerts
Photonics 2023, 10(7), 834; https://doi.org/10.3390/photonics10070834 - 18 Jul 2023
Cited by 3 | Viewed by 4385
Abstract
Direct pulp capping (DPC) is reliable in pulp exposure management. Objective: This study aimed to assess the success rate of DPC materials and different laser protocols. The included procedures were CO2 laser (n = 1147), Er: YAG laser (n = [...] Read more.
Direct pulp capping (DPC) is reliable in pulp exposure management. Objective: This study aimed to assess the success rate of DPC materials and different laser protocols. The included procedures were CO2 laser (n = 1147), Er: YAG laser (n = 69), and 980 nm diode laser (n = 124), on the one hand, and Ca (OH)2 (n = 376) and bioactive tricalcium silicate paste, on the other (n = 279). Materials and methods: Data from 1995 DPC cases were included. For laser groups, irradiation was used to coagulate the pulp exposure followed by Ca (OH)2 placement. Data with follow-up at 12, 24, and 36 months post-treatment were included. The irradiation parameters for the CO2 laser were as follows: energy density per pulse of 141 J/cm², 1 W power, 0.3 mm beam diameter, 100 ms pulse duration, and 1 Hz, and a series of five pulses maximum were delivered during 5 s. For the 980 diode lasers: 1.5 W power, continuous wave (CW), 400 μm fiber diameter, contact mode, 190.98 W/cm2 power density, and total delivered energy density of 2387 J/cm2. For the Er: YAG laser: 0.5 W output power, 9.95 J/cm2 energy density, a beam diameter of 0.8 mm, 300 µsec pulse duration, 10 Hz, non-contact mode, irradiation with air without water spray, and an average irradiation time of 8–10 s. Results: At the 3-year follow-up, the success percentages were as follows: CO2 (88.01%) > Ca (OH)2 (75.72%) > diode (70.01%) > Er: YAG (54.55%) > bioactive tricalcium silicate paste (51.1%). The timing of permanent filling (immediate or delayed), patient age, size of pulp exposure, tooth type, and exposure etiology significantly affected the success rate. Patients aged ≤ 35 years presented higher success (70.91%) compared to those ≥ 36 years (61.2%). Immediate permanent fillings increase the success rate (71.41%) compared to delayed permanent fillings (65.93%). Exposure in molars and premolars significantly lowers the success rate (60.3%) compared to canines and incisors (72.1%). Idiopathic pulp exposure presented higher success (72.58%) compared to caries-related causes (63.7%). Conclusion: The highest success rate was in the CO2 laser group followed by the diode and Ca (OH)2, Er: YAG, and bioactive tricalcium silicate material (biodentine) groups. The age factor, filling timing, size of exposure, tooth type, and exposure etiology can significantly affect the success rate of DPC. Full article
Show Figures

Figure 1

7 pages, 1304 KiB  
Communication
Distributed Bragg Reflector Laser Based on Composite Fiber Heavily Doped with Erbium Ions
by Mikhail I. Skvortsov, Kseniya V. Proskurina, Evgeniy V. Golikov, Alexander V. Dostovalov, Vadim S. Terentyev, Olga N. Egorova, Sergey L. Semjonov and Sergey A. Babin
Photonics 2023, 10(6), 679; https://doi.org/10.3390/photonics10060679 - 12 Jun 2023
Cited by 4 | Viewed by 2193
Abstract
A distributed Bragg reflector (DBR) laser with a specially designed, heavily Er3+-doped composite fiber of a length as short as 1.8 cm is demonstrated. The DBR laser, pumped by a 980 nm laser diode with power of up to 370 mW, [...] Read more.
A distributed Bragg reflector (DBR) laser with a specially designed, heavily Er3+-doped composite fiber of a length as short as 1.8 cm is demonstrated. The DBR laser, pumped by a 980 nm laser diode with power of up to 370 mW, generates single-frequency radiation at a wavelength of 1535 nm with a narrow instantaneous linewidth of <100 Hz and a high output power of 2 mW. The obtained Er3+-doped fiber laser parameters pave the way toward a broad range of practical applications from telecommunications and sensing to scientific research. Full article
(This article belongs to the Special Issue Fiber Laser and Their Applications)
Show Figures

Figure 1

11 pages, 2827 KiB  
Article
Wavelength-Tunable Narrow-Linewidth Laser Diode Based on Self-Injection Locking with a High-Q Lithium Niobate Microring Resonator
by Ting Huang, Yu Ma, Zhiwei Fang, Junxia Zhou, Yuan Zhou, Zhe Wang, Jian Liu, Zhenhua Wang, Haisu Zhang, Min Wang, Jian Xu and Ya Cheng
Nanomaterials 2023, 13(5), 948; https://doi.org/10.3390/nano13050948 - 6 Mar 2023
Cited by 14 | Viewed by 5116
Abstract
We demonstrate a narrow linewidth 980 nm laser by self-injection locking of an electrically pumped distributed-feedback (DFB) laser diode to a high quality (Q) factor (>105) lithium niobate (LN) microring resonator. The lithium niobate microring resonator is fabricated by photolithography-assisted chemo-mechanical [...] Read more.
We demonstrate a narrow linewidth 980 nm laser by self-injection locking of an electrically pumped distributed-feedback (DFB) laser diode to a high quality (Q) factor (>105) lithium niobate (LN) microring resonator. The lithium niobate microring resonator is fabricated by photolithography-assisted chemo-mechanical etching (PLACE) technique, and the Q factor of lithium niobate microring is measured as high as 6.91 × 105. The linewidth of the multimode 980 nm laser diode, which is ~2 nm measured from its output end, is narrowed down to 35 pm with a single-mode characteristic after coupling with the high-Q LN microring resonator. The output power of the narrow-linewidth microlaser is about 4.27 mW, and the wavelength tuning range reaches 2.57 nm. This work explores a hybrid integrated narrow linewidth 980 nm laser that has potential applications in high-efficient pump laser, optical tweezers, quantum information, as well as chip-based precision spectroscopy and metrology. Full article
(This article belongs to the Special Issue Nanophotonics Enabled by Femtosecond Lasers)
Show Figures

Figure 1

Back to TopTop