Next Article in Journal
Assessing Kinematic Variables in Short-Track Speed Skating Helmets: A Comparative Study between Traditional Rigid Foam and Anti-Rotation Designs
Previous Article in Journal
People with Parkinson’s Disease Are Able to Couple Eye Movements and Postural Sway to Improve Stability
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

The Effects of Compression Pants on Oxygen Consumption and Heart Rate during Long-Distance Running

by
Andrew Craig-Jones
*,
Daniel R. Greene
,
Haley L. Gilbert
,
Priya L. Giddens
and
Jonathan J. Ruiz-Ramie
Department of Kinesiology, Augusta University, Augusta, GA 30912, USA
*
Author to whom correspondence should be addressed.
Biomechanics 2024, 4(3), 473-482; https://doi.org/10.3390/biomechanics4030033
Submission received: 1 June 2024 / Revised: 22 July 2024 / Accepted: 24 July 2024 / Published: 4 August 2024

Abstract

The purpose of this study was to compare average rate of oxygen consumption (VO2), slow component of oxygen consumption (VO2 drift), heart rate (HR) and rating of perceived exertion (RPE) while wearing compression pants vs. a control garment during long-distance running. Methods: Nine injury-free and recreationally active participants (32 ± 11 years) were recruited for this study. Participants ran in full-leg compression pants (COMP) and a loose-fitting control garment (CON). Participants ran in each condition for 40 min at a preferred submaximal speed. The rate of oxygen consumption (VO2) was measured continuously via a metabolic cart throughout each condition. Both HR and RPE were recorded every 5 min during each condition. Oxygen consumption was averaged across the entirety of the steady state during the 40 min conditions for analysis. Additionally, the average from the first five minutes of the steady state was subtracted from the average of the last five minutes to assess VO2. A paired t-test was used to assess for differences for both variables. Both HR and RPE were each compared between conditions using 2 (garment) × 8 (time) repeated measure ANOVAs (α = 0.05). Results: There were no differences between VO2 or VO2 drift while running with full-leg compression pants vs. the control garment (p > 0.05). Neither RPE nor HR were influenced by the garments (p > 0.05) or time (p > 0.05) during each condition. Conclusion: Wearing compression pants did not result in reduced VO2, VO2 drift, HR or RPE during a long-distance run. Although measured performance variables were not aided using compression pants, there were no negative effects to the use of compression pants.
Keywords: compression; oxygen consumption; heart rate; RPE compression; oxygen consumption; heart rate; RPE

Share and Cite

MDPI and ACS Style

Craig-Jones, A.; Greene, D.R.; Gilbert, H.L.; Giddens, P.L.; Ruiz-Ramie, J.J. The Effects of Compression Pants on Oxygen Consumption and Heart Rate during Long-Distance Running. Biomechanics 2024, 4, 473-482. https://doi.org/10.3390/biomechanics4030033

AMA Style

Craig-Jones A, Greene DR, Gilbert HL, Giddens PL, Ruiz-Ramie JJ. The Effects of Compression Pants on Oxygen Consumption and Heart Rate during Long-Distance Running. Biomechanics. 2024; 4(3):473-482. https://doi.org/10.3390/biomechanics4030033

Chicago/Turabian Style

Craig-Jones, Andrew, Daniel R. Greene, Haley L. Gilbert, Priya L. Giddens, and Jonathan J. Ruiz-Ramie. 2024. "The Effects of Compression Pants on Oxygen Consumption and Heart Rate during Long-Distance Running" Biomechanics 4, no. 3: 473-482. https://doi.org/10.3390/biomechanics4030033

APA Style

Craig-Jones, A., Greene, D. R., Gilbert, H. L., Giddens, P. L., & Ruiz-Ramie, J. J. (2024). The Effects of Compression Pants on Oxygen Consumption and Heart Rate during Long-Distance Running. Biomechanics, 4(3), 473-482. https://doi.org/10.3390/biomechanics4030033

Article Metrics

Back to TopTop