A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid

1
A.M. Butlerov’ Chemistry Institute, Kazan Federal University, 18 Kremlevskaya Street, Kazan 420008, Russia
2
Analytical Chemistry Department, Chemical Technology Institute, Ural Federal University, 19 Mira Street, Ekaterinburg 620002, Russia
*
Author to whom correspondence should be addressed.
Chemosensors 2024, 12(6), 98; https://doi.org/10.3390/chemosensors12060098
Submission received: 30 April 2024 / Revised: 21 May 2024 / Accepted: 28 May 2024 / Published: 4 June 2024

Abstract

Simple and reliable electrochemical sensors are highly demanded in medicine and pharmacy for the fast determination of metabolites and biomarkers of diseases. In this work, a flow-through biosensor system was developed on the base of a screen-printed carbon electrode modified with pillar[3]arene[2]quinone and ferrocene implemented in carbon black. The modification was performed in a single step and resulted in the formation of a stable layer with good operation characteristics. Uricase was immobilized on the inner walls of a replaceable reactor by carbodiimide binding. A flow-through cell was manufactured by 3D printing from poly(lactic acid). The flow-through system was first optimized on the hydrogen peroxide assay and then used for the determination of 1 nM–0.1 mM uric acid (limit of detection 0.3 nM, 20 measurements per hour). Implementation of ferrocene resulted in a synergetic increase in the cathodic current of H2O2 reduction measured by flow switching in chronoamperometric mode. The developed system was tested on the determination of uric acid in artificial urine and Ringer–Locke solution and showed a recovery rate of 96–112%. In addition, the possibility of determination of H2O2 in commercial disinfectants was shown. Easy assembly, fast and reliable signal and low consumption of the reagents make the system developed attractive for routine clinical analysis of metabolites.
Keywords: flow-through cell; chronoamperometry; uricase biosensor; ferrocene; pillarquinone; uricase determination; hydrogen peroxide determination flow-through cell; chronoamperometry; uricase biosensor; ferrocene; pillarquinone; uricase determination; hydrogen peroxide determination

Share and Cite

MDPI and ACS Style

Stoikov, D.; Shafigullina, I.; Shurpik, D.; Stoikov, I.; Evtugyn, G. A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid. Chemosensors 2024, 12, 98. https://doi.org/10.3390/chemosensors12060098

AMA Style

Stoikov D, Shafigullina I, Shurpik D, Stoikov I, Evtugyn G. A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid. Chemosensors. 2024; 12(6):98. https://doi.org/10.3390/chemosensors12060098

Chicago/Turabian Style

Stoikov, Dmitry, Insiya Shafigullina, Dmitry Shurpik, Ivan Stoikov, and Gennady Evtugyn. 2024. "A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid" Chemosensors 12, no. 6: 98. https://doi.org/10.3390/chemosensors12060098

APA Style

Stoikov, D., Shafigullina, I., Shurpik, D., Stoikov, I., & Evtugyn, G. (2024). A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid. Chemosensors, 12(6), 98. https://doi.org/10.3390/chemosensors12060098

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop