Analysis of Series-Parallel (SP) Compensation Topologies for Constant Voltage/Constant Current Output in Capacitive Power Transfer System

1
School of Rail Transit, Chongqing Vocational College of Public Transportation, Chongqing 402247, China
2
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
*
Author to whom correspondence should be addressed.
Electronics 2023, 12(1), 245; https://doi.org/10.3390/electronics12010245
Submission received: 19 November 2022 / Revised: 9 December 2022 / Accepted: 12 December 2022 / Published: 3 January 2023
(This article belongs to the Special Issue Wireless Power Transfer and Wireless Energy Harvest)

Abstract

This paper analyzed the four series-parallel (SP) compensation topologies to achieve constant current (CC) and voltage (CV) output characteristics and zero phase angle (ZPA) input conditions with fewer compensation components in the capacitive power transfer (CPT) system. There are three main contributions. Firstly, the universal methodology of SP compensation topologies was constructed to achieve CC, CV output, and ZPA conditions. Secondly, four specific SP compensation topologies were investigated and summarized, including double-sided LC, double-sided CL, CL−LC, and LC−CL topologies. Their input–output characteristics are provided, and system efficiency is analyzed. Thirdly, the CL−LC and LC−CL topologies were proposed to realize ZPA conditions under CC and CV output without any external regulating circuit. A CV output LC−CL experiment prototype was implemented to validate the theoretical analysis.
Keywords: capacitive power transfer (CPT); compensation topology; zero phase angle; constant voltage/current output capacitive power transfer (CPT); compensation topology; zero phase angle; constant voltage/current output

Share and Cite

MDPI and ACS Style

Li, S.; Tang, C.; Cheng, H.; Wang, Z.; Luo, B.; Jiang, J. Analysis of Series-Parallel (SP) Compensation Topologies for Constant Voltage/Constant Current Output in Capacitive Power Transfer System. Electronics 2023, 12, 245. https://doi.org/10.3390/electronics12010245

AMA Style

Li S, Tang C, Cheng H, Wang Z, Luo B, Jiang J. Analysis of Series-Parallel (SP) Compensation Topologies for Constant Voltage/Constant Current Output in Capacitive Power Transfer System. Electronics. 2023; 12(1):245. https://doi.org/10.3390/electronics12010245

Chicago/Turabian Style

Li, Shiqi, Chunlin Tang, Hao Cheng, Zhulin Wang, Bo Luo, and Jing Jiang. 2023. "Analysis of Series-Parallel (SP) Compensation Topologies for Constant Voltage/Constant Current Output in Capacitive Power Transfer System" Electronics 12, no. 1: 245. https://doi.org/10.3390/electronics12010245

APA Style

Li, S., Tang, C., Cheng, H., Wang, Z., Luo, B., & Jiang, J. (2023). Analysis of Series-Parallel (SP) Compensation Topologies for Constant Voltage/Constant Current Output in Capacitive Power Transfer System. Electronics, 12(1), 245. https://doi.org/10.3390/electronics12010245

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.