1. Introduction
The development of society, economy, and technology has placed higher demands on the blast resistance, sealing integrity, and safety reliability of structures against internal explosions. Reinforced concrete (RC) structures are commonly used for internal blast containment, finding widespread application in areas such as nuclear reactor containment vessels, and storage facilities for weapons, ammunition, and explosive hazardous materials [
1,
2,
3]. To improve the internal blast resistance of RC structures, extensive research has been conducted by scholars domestically and internationally. Cheng Fengsheng et al. [
4] used numerical simulation combined with experimental studies to analyze the distribution of shock wave overpressure load on the inner wall of a box-type RC confinement structure under internal explosion. Guo et al. [
5] conducted internal explosion tests and finite element analysis on RC structures. Their research showed that the internal blast load increases as the venting area decreases. Liu Jiening et al. [
6] constructed a full-scale RC structure test model and used a combination of testing and numerical simulation to study the anti-explosion performance of RC structures under internal blast loading.
However, due to the performance characteristics of concrete materials having different tensile and compressive strengths, traditional single-layer RC structures still face difficult-to-overcome problems such as low resistance, susceptibility to cracking, and poor structural sealing and safety [
7]. Foam materials such as foamed concrete, aluminum foam, and polyurethane foam are characterized by low density and a relatively long yield stress plateau [
8,
9]. Multi-layer composite structures using foam materials as core layers can effectively attenuate explosion shock waves [
10,
11,
12] and have become a research hotspot in explosion protection engineering. Liu Yining et al. [
13] used LS-DYNA software to calculate the dynamic blast response of a composite blast wall containing an aluminum foam energy-absorbing layer, analyzing the influence of structural parameters and relative density of the aluminum foam sandwich panel on its blast resistance. Zhang Yong [
14] conducted explosion tests on composite structures composed of polyurethane foam, aluminum and concrete. The results showed that the explosion protection performance of polyurethane foam aluminum is superior to that of aluminum foam. Fang Qin et al. [
15,
16] used experimental and numerical simulation methods to study the influence of foamed concrete thickness and strength on the blast resistance of composite protective structures, analyzing the blast wave attenuation characteristics of foamed concrete under blast wave action. In recent years, research on multi-layer composite structures for blast protection has advanced significantly, encompassing both engineering applications and theoretical/scientific investigations. Engineering research has focused on innovative configurations and materials, such as novel composite containment vessels with multi-layer linings [
17], advanced sandwich panels for internal explosion [
18], and cylindrical structures with new core designs [
19]. The development of enhanced energy-absorbing materials, like nanoparticle-stabilized foam concrete [
20] and novel auxetic composites [
21], has also progressed. On the theoretical and computational front, significant efforts have been made in high-fidelity modeling for damage assessment [
22], advanced fluid–structure interaction frameworks [
23], and refined analytical models for blast mitigation in cylindrical vessels [
24] and sandwich cylinders [
25]. Combined theoretical–numerical studies continue to elucidate the internal blast response of cylindrical shells [
26,
27]. Furthermore, the rise of data-driven techniques has opened new avenues; machine learning (ML) algorithms, for instance, have been successfully applied to predict damage in structures under dynamic loads [
28,
29]. These studies demonstrate the potential of advanced computational methods, including data-driven techniques, to complement experimental investigations in understanding and predicting complex structural dynamic responses. These works collectively highlight the ongoing efforts in blast protection research.
In fields such as high-risk ammunition storage, there are extremely high requirements for the sealing and safety of structures against internal explosions, which traditional single-layer RC structures struggle to meet. Leveraging the high resistance characteristic of multi-layer composite structures with energy-absorbing layers, this paper proposes a rigid–flexible combined multi-layer composite confinement structure for internal explosion protection. The novelty of the proposed system lies in its specific configuration designed for cylindrical confinement and the direct experimental comparison between two fundamentally different, yet practically common, energy-absorbing interlayer materials: foamed concrete and dense sandy soil. The main body of the multi-layer confinement structure consists of inner and outer RC layers and a sandwich energy-absorbing layer. Under internal blast loading, the goal is to dissipate internal explosion energy through the deformation of the inner structural layer and the wave-attenuation and energy-absorption of the absorbing layer, thereby reducing the load acting on the outer structural layer, protecting the outer layer to remain in an elastic state undamaged, while improving structural resistance and sealing.
The novelty of this experimental study lies in the investigation of a cylindrical, rigid–flexible-rigid multi-layer composite confinement system under internal explosion. Unlike previous studies focusing on planar sandwich panels or load analysis alone, this work provides comprehensive, synchronized data on the internal blast field, interlayer dynamic interaction, and global structural response, aiming to reveal the synergistic blast mitigation mechanism specific to this configuration for enclosed cylindrical vessels. However, as highlighted in the recent literature, most of these studies focus on separate analyses of either the internal explosion load or the structural dynamic response, often employing simplified geometries (e.g., plates, beams) or single material cores. Particularly, there is a lack of reported experimental research that directly compares the dynamic response and protective efficacy of different, readily available energy-absorbing materials (such as foamed concrete versus dense soil) within a full-scale, cylindrical, multi-layer composite confinement structure under internal blast loading. To address this gap and study the internal blast resistance performance of multi-layer composite confinement structures, this paper designed and fabricated two test models of multi-layer confinement structures with energy-absorbing layer materials of foamed concrete and dense sandy soil, respectively. Internal explosion tests were conducted on both models using centrally placed charges. The magnitude and distribution of the load acting on the inner wall of the structure during internal explosion were analyzed, and the deformation characteristics and mechanical mechanisms of the multi-layer composite confinement structure under internal blast loading were studied, providing a basis for numerical calculation and theoretical analysis.
Prior Publication Context and Originality Statement
While the experimental campaign was originally conducted as part of the corresponding author’s doctoral research [
30], the present article represents a distinct and substantially expanded contribution. Portions of the raw datasets were previously tabulated in a related collaborative report [
31]. Crucially, this work extends far beyond the original documentation: it provides (1) a completely rewritten narrative with updated literature synthesis; (2) new material characterization data (Tables 3 and 4); (3) a dedicated comparative framework quantifying the mechanistic differences between foamed concrete and sandy soil energy-absorbing layers; and (4) original discussions on end-plate impulsive loading and scale-effect limitations for cylindrical containment design. The reuse of these foundational measurements is fully disclosed to support the novel analytical contributions presented herein.
3. Results
3.1. Internal Explosion Load
There are 4 measurement points for the explosion shock wave load on the inner wall surface: P-A-1, P-B-1, P-C-1, and P-D-1.
Figure 10 shows the explosion shock wave load waveforms at measurement point P-A-1 (detonation center cross-section) and measurement point P-D-1 (end plate center) for each charge mass during internal explosion. The arrival time of the shock wave at both measurement points decreases as the charge mass increases. The load waveform at point P-A-1 exhibits a first pulse with a larger peak, followed by several subsequent pulses with smaller peaks. At point P-D-1, due to the continuous reflection of the explosion shock wave on the inner wall surface and its convergence along the axis, the first shock wave pulse appears as an aggregation of several pulses.
The explosion shock wave load is generally characterized by peak overpressure and specific impulse.
Table 7 and
Table 8 present the reflected peak overpressure (PR) and specific impulse (IR) at each measurement point for each internal explosion test. The peak overpressure at all measurement points increases with the increase in charge mass. For Model 1 and Model 2, the peak overpressure at measurement point P-A-1 on the inner wall surface at the detonation center cross-section for the 0.8 kg charge is 3.82 times and 4.65 times that for the 0.15 kg charge, respectively. The variation in peak overpressure at points P-B-1 and P-C-1 with charge mass is relatively smaller compared to point P-A-1. Among the four explosion shock wave load measurement points on the inner wall surface, point P-A-1 at the detonation center ring plane has the largest peak overpressure. The peak overpressure decays rapidly along the axial direction of the structure with increasing distance from the detonation center cross-section, especially more pronounced at closer distances. Measurement point P-B-1 is 0.8 m from the detonation center cross-section, and its peak overpressure under various charge masses is about 11.36% to 15.33% of that at point P-A-1. As the distance from the detonation center increases, the decay rate of the wall blast load peak overpressure slows down. Measurement point P-C-1 is 1.6 m from the detonation center cross-section; at the same charge mass, its peak overpressure is about 52.98% to 70.67% of that at point P-B-1. The explosion load measurement point P-D-1 at the center of the multi-layer confinement structure end plate is 2.5 m from the detonation center cross-section, but its peak overpressure under all charge masses is higher than that at point P-C-1, which is closer to the detonation center. For the other four charge masses besides 0.15 kg, it is even higher than that at point P-B-1.
Similar to the variation pattern of the explosion peak overpressure, the specific impulse at all measurement points increases with the increase in charge mass. The specific impulse of the explosion load decreases along the axial direction of the structure as the distance from the detonation center cross-section increases, but the reduction magnitude is smaller compared to the decay of peak overpressure; the attenuation of specific impulse is relatively slower. For the same charge mass, the specific impulse of the explosion load at point P-B-1 is about 24.35% to 33.86% of that at point P-A-1. This indicates that as the distance from the detonation center increases (i.e., the scaled distance increases), the positive pressure duration of the explosion shock wave load on the inner wall surface of the structure is prolonged. Notably, at measurement point P-D-1 at the center of the structural end plate, which is farthest from the detonation center, its specific impulse is even larger than that at the detonation center cross-section point P-A-1. This is consistent with the experimental and computational results regarding internal explosion loads in cylindrical explosion vessels reported in references [
32,
33]. The main reasons for this phenomenon are the formation of axial jets due to the collision of reflected shock waves from the cylindrical wall surface after reflection and enhancement on the central axis, and the collision enhancement of reflected waves from adjacent inner surfaces [
32]. This indicates that for cylindrical multi-layer confinement structures under internal explosion, failure is not necessarily controlled by the deformation at the detonation center cross-section; sometimes, the end plates at both ends of the structure may fail first. This is an issue that must be noted in the research and application of cylindrical multi-layer anti-internal-explosion structures.
Due to the complex flow field inside a confined structure caused by the repeated reflection of explosion shock waves on the inner wall surface and the interaction between reflected waves, current research on internal explosion loads in confined structures generally focuses only on the detonation center cross-section. The experimental data from measurement point P-A-1 at the detonation center cross-section of the test models were compared with calculation results from empirical formulas proposed in references [
32,
33,
34] for the reflected load on the wall of a confined structure under internal explosion. The comparison results for reflected pressure peak and specific impulse are shown in
Figure 11 and
Figure 12, respectively. The experimental results show good agreement with the results calculated by the various empirical formulas. As shown in
Figure 12, the reflected impulse for both models generally exhibits an increasing trend with charge mass. However, a notable anomaly is observed for Model 1: the impulse value at the 0.20 kg charge (831.11 Pa·s) is higher than that at the 0.30 kg charge (807.17 Pa·s), which contradicts the expected monotonic increase. Given this inconsistency with the physical trend, the specific data point for Model 1 at 0.20 kg is considered likely affected by experimental error and is treated as an outlier in the subsequent analysis. The underlying data are provided in
Table 8.
3.2. Structural Strain
The peak strain values at each strain measurement point for Model 1 and Model 2 in each test are shown in
Table 9 and
Table 10, respectively. In the tables, “/” indicates that test data for that item was not acquired. For both Model 1 and Model 2, at the same measurement point and under the same charge mass, the peak circumferential strain is greater than the peak axial strain. In the hoop (circumferential) strain diagram, positive and negative values represent tensile and compressive strains, respectively, consistent with standard sign conventions in structural dynamics. The hoop direction refers to the circumferential axis of the cylindrical containment structure, perpendicular to the axial and radial directions. Under all charge masses, the peak circumferential and axial strains in the inner structural layer are much larger than those in the outer structural layer. For the 0.8 kg charge, the peak circumferential strain at the inner reinforcement of the inner layer (point A-H-1) for Model 1 and Model 2 is 19.20 times and 15.23 times that at the inner reinforcement of the outer layer (point A-H-3), respectively. The peak circumferential and axial strains in the inner structural layer increase rapidly with increasing charge mass. For the 0.8 kg charge, the peak circumferential strain at the inner reinforcement of the inner layer (point A-H-1) for Model 1 and Model 2 is 5.04 times and 4.23 times that for the 0.15 kg charge, respectively. The peak circumferential and axial strains in the outer structural layer change relatively little, indicating that the energy-absorbing layer can effectively reduce the deformation of the outer layer by increasing the deformation of the inner layer.
The experimental data used for comparison in
Table 9 and
Table 10 were originally obtained from the author’s previous work [
30] and were later reported in [
31]. Comparing
Table 9 and
Table 10, it can be found that under the 0.15 kg TNT charge, the peak values of circumferential and axial strain at each measurement point for Model 1 and Model 2 are very close. This is mainly because, under a small charge mass, the inner RC layer primarily bears the internal blast load, and the circumferential deformation of the inner RC layer is very small at this time. Therefore, the influence of the energy-absorbing layer on the dynamic response of the multi-layer confinement structure is not obvious. However, as the charge mass increases, the peak circumferential and axial strains in the inner layer of Model 1 are greater than those of Model 2, while the peak circumferential and axial strains in the outer layer of Model 1 are less than those of Model 2. For the 0.8 kg charge, the peak circumferential strain at the inner layer point A-H-1 and the outer layer point A-H-3 of Model 1 are 1.17 times and 93.2% of those at the same points in Model 2, respectively. This indicates that as the internal explosion charge mass increases, the sandy soil energy-absorbing layer in Model 2 is less effective in regulating the deformation of the inner and outer layers compared to the foamed concrete energy-absorbing layer in Model 1.
Figure 13 and
Figure 14 show the circumferential and axial strain waveforms, respectively, at measurement points on cross-section A of Model 1 under the 0.8 kg charge. For different charge masses, both the circumferential and axial strains at various points of the multi-layer composite confinement structure reach their peak values in the first vibration cycle and then decrease rapidly after reaching the peak.
3.3. Structural Mechanical Characteristics
The contact pressure between layers of the multi-layer confinement structure is an important indicator reflecting the effect of the energy-absorbing layer.
Table 11 presents the peak contact pressures at the measurement points between structural layers for each test condition.
For both Model 1 and Model 2, when the charge mass is small, the contact pressures between the energy-absorbing layer and the inner/outer structural layers are very small. For the 0.15 kg charge, the peaks at measurement point P-A-3 for Model 1 and Model 2 are only 22.06 kPa and 46.52 kPa, respectively. At this time, the force and deformation of the multi-layer confinement structure under internal blast loading are mainly borne by the inner RC layer, and as known from the structural strain analysis, the deformation of the inner layer is small at this stage. The pressure peaks at all measurement points increase rapidly with increasing charge mass, most notably at the detonation center cross-section A measurement points. For the 0.8 kg charge, the pressure peaks at measurement point P-A-2 for Model 1 and Model 2 are 13.25 and 14.43 times those for the 0.15 kg charge, respectively.
For different charge masses, the contact pressure measurement points between layers of the multi-layer confinement structure all have the largest peak at the detonation center cross-section measurement points. The farther the cross-section of the measurement point is from the detonation center, the smaller the contact pressure peak, and the magnitude of change in pressure peak with increasing charge mass also decreases. For the 0.8 kg charge, the pressure peaks at measurement point P-C-3 for Model 1 and Model 2 are 6.85% and 7.96% of their respective pressure peaks at point P-A-3. This is mainly caused by the rapid decrease in internal explosion load and the deformation of the inner layer of the multi-layer confinement structure with increasing distance from the detonation center cross-section.
For both Model 1 and Model 2, the peak contact pressure at the interface between the inner RC layer and the energy-absorbing layer at each cross-section is greater than that at the interface between the energy-absorbing layer and the outer RC layer. Moreover, the larger the internal explosion charge mass, the smaller the ratio of the peak contact pressure at the interface between the energy-absorbing layer and the outer structural layer relative to that at the interface between the inner layer and the energy-absorbing layer, i.e., the wave attenuation effect of the energy-absorbing layer becomes more pronounced. For the 0.8 kg charge, the pressure peaks at measurement point P-A-3 for Model 1 and Model 2 are 53.79% and 40.94% of the pressure peaks at point P-A-2, respectively. This indicates that the energy-absorbing layers in both Model 1 and Model 2 can effectively attenuate the intensity of the stress wave and the magnitude of the load transmitted from the inner layer to the outer layer of the multi-layer confinement structure.
Comparing the pressure peaks of Model 1 and Model 2 under the same charge mass, it is found that at the same location, the pressure peaks of Model 2 are generally higher than those of Model 1, especially under larger charge masses and at contact pressure measurement points on the structural detonation center cross-section. This is consistent with the variation pattern of strain peaks in the inner and outer layers of the two test models. This is primarily due to the lower density and distinct yield plateau of the foamed concrete.
Figure 15 and
Figure 16 show the contact pressure time-history curves at measurement points P-A-2 and P-A-3 on the detonation center cross-section A for Model 1 and Model 2, respectively, under the 0.8 kg charge. For both test models, the pressure arrival time and peak achievement time at point P-A-2 are earlier than those at point P-A-3. After the explosion, the contact pressure at each measurement point rapidly reaches its peak, then declines and transforms into an oscillating curve containing several smaller peaks.
4. Discussion
The experimental results clearly demonstrate the performance differences between the two energy-absorbing materials. The data on strain and interlayer contact pressure consistently show that the foamed concrete layer (Model 1) is more effective than the sandy soil layer (Model 2) in attenuating the blast load and protecting the outer structural layer, especially under higher charge masses. This can be attributed to the intrinsic material properties of foamed concrete, such as its lower density and porous structure, which provide a more efficient energy absorption mechanism through crushing and plastic deformation compared to the denser, frictional energy dissipation of sandy soil. This performance difference is corroborated by post-test inspections. For charge masses up to 0.475 kg, only minor hairline cracks were observed on the inner RC surface of both models. After the 0.8 kg test, more extensive micro-cracking was visible on the inner layer of the structure with foamed concrete, while the structure with sandy soil showed comparatively less cracking. Importantly, neither model exhibited through-thickness cracking, significant permanent deformation, or loss of containment integrity. This visual assessment confirms that the energy-absorbing layer, particularly the foamed concrete, effectively protected the outer RC layer, which remained elastic and undamaged, aligning perfectly with the quantitative strain data.
The finding that the specific impulse at the end plate (P-D-1) can exceed that at the detonation center (P-A-1) is significant for design. It highlights that for cylindrical confinement structures, the end plates may be critical failure points due to wave focusing and reflection phenomena, not just the region closest to the charge. Consequently, this necessitates specific reinforcement or design considerations for the end closures in such structures, such as increased thickness, enhanced reinforcement detailing, or the use of higher-strength materials to resist the amplified impulsive loading, which might be underestimated by conventional design methods focusing solely on the detonation-center section.
The good agreement between the measured blast loads at the detonation center and established empirical formulas validates the experimental setup and measurement techniques. However, the significant amplification of specific impulse at the end plate (P-D-1), which exceeds that at the detonation center (P-A-1), highlights a critical limitation of these simplified empirical approaches. These formulas, typically developed for or calibrated against detonation-center conditions, fail to capture the complex three-dimensional wave dynamics in confined cylindrical chambers, such as wave focusing and axial jet formation, that lead to enhanced loading on the end closures. This discrepancy, coupled with the observed axial load variation, demonstrates that reliance solely on empirical methods focused on the detonation center is insufficient for the complete assessment and design of cylindrical confinement structures. Consequently, the end plates must be recognized as potential critical failure points and require specific reinforcement in design. For accurate prediction of these complex load distributions, advanced numerical simulations capable of capturing the full 3D fluid–structure interaction are an essential complement to empirical approaches.
When interpreting the experimental results, the sources of uncertainty and the basis for data reliability must be considered. The inherent uncertainty of the pressure sensors is estimated to be within ±3% of the full scale. To minimize the effects of experimental variability, the relatively large scale of the test model helped reduce the sensitivity to minor imperfections in charge placement and initiation symmetry, which were carefully controlled during setup. However, some inherent scatter due to these factors is acknowledged. Due to the destructive nature and high cost of each test, and to ensure that the structural condition was pristine for each charge mass, only a single test was conducted for each unique model and charge mass combination. The reliability of the presented data is therefore assessed based on the physical consistency of the measurements (e.g., smooth spatial decay of pressure, logical strain distributions) and the systematic trends observed across different charge masses, rather than on statistical repeatability.
It is important to note that while geometric similarity provides a foundational framework, direct extrapolation of the quantitative results (e.g., absolute strain or displacement values) to full-scale prototypes requires caution. Scale effects, arising from factors such as the non-scalability of material properties (e.g., strain-rate sensitivity, fracture behavior) and the potential change in failure modes with size, may lead to deviations. The current study primarily validates the relative performance and mechanistic superiority of the foamed concrete interlayer compared to sandy soil within this multi-layer configuration. For accurate prediction of prototype behavior, future work should incorporate distorted scaling laws that account for strain-rate effects and conduct validation tests on larger-scale models.