Next Article in Journal
Emerging Resident Concerns as Signals of a Paradigm Shift in the Spatial Infrastructure for Integrated Community Care: Focusing on Yeonpyeong Island, a Medically Isolated Declining Region of Korea
Previous Article in Journal
Linking Health, Comfort and Indoor Environmental Quality in Classrooms with Mechanical Ventilation or Window Airing: A Controlled Observational Study
Previous Article in Special Issue
Internal Force Distribution Characteristics of Top-Chord-Free Vierendeel-Truss Composite Slab
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods

1
Architectural Design & Research Institute of SCUT Co., Ltd., Guangzhou 510641, China
2
China Construction Science and Industry Corporation Ltd., Shenzhen 518000, China
3
School of Civil and Transportation Engineering, South China University of Technology, Guangzhou 510641, China
*
Author to whom correspondence should be addressed.
Buildings 2026, 16(1), 216; https://doi.org/10.3390/buildings16010216
Submission received: 29 November 2025 / Revised: 23 December 2025 / Accepted: 28 December 2025 / Published: 3 January 2026
(This article belongs to the Special Issue Advances in Steel and Composite Structures)

Abstract

Research on the configuration and mechanical performance of arch-column-tie beam joints, which combine features of arch-tie beam joints and tubular joints, remains limited, particularly for long-span structures subjected to heavy loads at high building stories. This study focuses on a joint in an engineering structure comprising a circular arch beam, a square-section inclined column, and a tie beam, where both the arch and the inclined column are concrete-filled steel tube (CFST) members. A novel joint configuration was proposed, then a refined finite element model was established. The joint’s mechanical mechanism and failure mode under axial compression in the arch beam were investigated, considering two conditions: the presence of prestressed high-strength rods and the failure of the rods. Subsequently, a parametric study was conducted to investigate the influence of variations in the web thickness of the tie beam, the steel tube wall thickness of the arched beam, the steel tube wall thickness of the supporting inclined column, and the strength grades of steel and concrete on the bearing capacity behavior and failure modes. Numerical simulation results indicate that the joint remains elastic under the design load for both conditions, meeting the design requirements. The joint reaches its ultimate capacity when extensive yielding occurs in the tie beam along the junction region with the circular arch beam, as well as in the steel tube of the arch beam. At this stage, the steel plates and concrete within the joint zone remain elastic, ensuring reliable load transfer. The maximum computed load of the model with prestressed rods was 2.28 times the design load. The absence of prestressed rods could lead to a significant increase in the high-stress area within the web of the tie beam, decreasing the joint’s stiffness by 12.4% at yielding, but have a limited effect on its maximum bearing capacity. Gradually increasing the wall thickness of the arch beam’s steel tube shifts the failure mode from arch-beam-dominated yielding to tie-beam-dominated yielding along the junction region. Increasing the steel strength grade is more efficient in enhancing the bearing capacity than increasing the concrete strength grade. Finally, a design methodology for the joint zone was established based on three aspects: local stress transfer at the bottom of the arch beam, force equilibrium between the arch beam and the tie beam, and the biaxial compression state of the concrete in the joint zone. Furthermore, the construction process and mechanical analysis methods for various construction stages were proposed.
Keywords: concrete-filled steel tube; arch-tie beam joint; numerical simulation; mechanical mechanism; design method concrete-filled steel tube; arch-tie beam joint; numerical simulation; mechanical mechanism; design method

Share and Cite

MDPI and ACS Style

Li, C.; Su, X.; Zuo, Z.; Huang, L.; Zhou, Y. Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods. Buildings 2026, 16, 216. https://doi.org/10.3390/buildings16010216

AMA Style

Li C, Su X, Zuo Z, Huang L, Zhou Y. Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods. Buildings. 2026; 16(1):216. https://doi.org/10.3390/buildings16010216

Chicago/Turabian Style

Li, Chongyang, Xianggang Su, Zhiliang Zuo, Lehua Huang, and Yuezhou Zhou. 2026. "Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods" Buildings 16, no. 1: 216. https://doi.org/10.3390/buildings16010216

APA Style

Li, C., Su, X., Zuo, Z., Huang, L., & Zhou, Y. (2026). Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods. Buildings, 16(1), 216. https://doi.org/10.3390/buildings16010216

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop