Next Article in Journal
Comparison of Atmospheric Carbon Dioxide Concentrations Based on GOSAT, OCO-2 Observations and Ground-Based TCCON Data
Previous Article in Journal
Multi-Temporal Analysis of Environmental Carrying Capacity and Coastline Changes in Yueqing City
Previous Article in Special Issue
Joint Design of Complementary Sequence and Receiving Filter with High Doppler Tolerance for Simultaneously Polarimetric Radar
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse

1
Air and Missile Defense College, Air Force Engineering University, Xi’an 710051, China
2
College of Information and Communication, National University of Defense Technology, Wuhan 430010, China
3
Test and Training Base, National University of Defense Technology, Xi’an 710106, China
*
Author to whom correspondence should be addressed.
Remote Sens. 2023, 15(21), 5171; https://doi.org/10.3390/rs15215171
Submission received: 6 September 2023 / Revised: 16 October 2023 / Accepted: 17 October 2023 / Published: 30 October 2023
(This article belongs to the Special Issue Theory and Applications of MIMO Radar)

Abstract

The transmitted beam of frequency diversity array (FDA) has the range–angle–time coupling property, which has essential applicative potential in angle deception and active anti-jamming. In this paper, the concept of time index within pulse is introduced. Firstly, the phase characteristics of FDA-transmitted signals based on the time index within pulse concept are studied. Then, the deceptive angle performance of FDA-transmitted signals is discussed. The theoretical analysis and simulation results show that the phase characteristics of the FDA signal are not related to the range, but to the time index within pulse. With the phase center as the reference point, the phase is equal as long as the time index within the pulse is the same. Angle deception and active anti-jamming can be achieved using the optimized frequency increment of each FDA.
Keywords: frequency diversity array (FDA); time index within pulse; phase center; angle deception; active anti-jamming frequency diversity array (FDA); time index within pulse; phase center; angle deception; active anti-jamming

Share and Cite

MDPI and ACS Style

Zhou, C.; Wang, C.; Gong, J.; Tan, M.; Bao, L.; Liu, M. Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse. Remote Sens. 2023, 15, 5171. https://doi.org/10.3390/rs15215171

AMA Style

Zhou C, Wang C, Gong J, Tan M, Bao L, Liu M. Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse. Remote Sensing. 2023; 15(21):5171. https://doi.org/10.3390/rs15215171

Chicago/Turabian Style

Zhou, Changlin, Chunyang Wang, Jian Gong, Ming Tan, Lei Bao, and Mingjie Liu. 2023. "Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse" Remote Sensing 15, no. 21: 5171. https://doi.org/10.3390/rs15215171

APA Style

Zhou, C., Wang, C., Gong, J., Tan, M., Bao, L., & Liu, M. (2023). Phase Characteristics and Angle Deception of Frequency-Diversity-Array-Transmitted Signals Based on Time Index within Pulse. Remote Sensing, 15(21), 5171. https://doi.org/10.3390/rs15215171

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop