Article

The Development of Energy-Efficient and Sustainable Buildings: A Case Study in Vietnam

1
Vietnam Institute for Building Materials, Ministry of Construction, Hanoi 100000, Vietnam
2
Fraunhofer Institut for Building Physics, Nobelstraße 12, 70569 Stuttgart, Germany
3
Department of Architecture and Civil Engineering, Energy and Building Services, Technische Hochschule Lübeck, Mönkhofer Weg 239, 23562 Lübeck, Germany
*
Authors to whom correspondence should be addressed.
Sustainability 2023, 15(22), 15921; https://doi.org/10.3390/su152215921
Submission received: 7 September 2023 / Revised: 20 October 2023 / Accepted: 31 October 2023 / Published: 14 November 2023

Abstract

:
This paper reports on collaborative activities to promote energy- and resource-efficient construction practices in Vietnam. First, the governance framework was introduced, including government decrees and technical standards. Then, a laboratory with building physics measurement technology was designed and partly set up at the local partner, the Vietnam Institute for Building Materials (VIBM). This can be used to determine the essential characteristic values required for the implementation of energy standards. The requirements of the national technical regulation on energy-efficient buildings of Vietnam—QCVN09:2017/BXD—form the basis for the prioritization of characteristic values. Furthermore, the description of basic characteristic values from international standards can also be used for calculations to optimize the energy consumption of buildings. To carry out transient hygrothermal computer simulations, special characteristic values are also included. These are particularly useful for the research and development of new building materials and the evaluation of entire buildings in terms of thermal and moisture protection. In this way, the practical means for implementing governance instruments are provided, and the associated technical applications are supported. Based on the example of Vietnam, this paper indicates how a developing country can develop a road map for improving its systems for testing, rating, and labeling building materials for energy performance towards sustainable development.

1. Introduction

The building sector accounts for 35% of global energy consumption [1]. According to the International Energy Agency (IEA), the building sector is one of the most cost-effective sectors for reducing global energy consumption and CO2 emissions [2]. Many countries have issued building energy policies to reduce energy consumption and CO2 emissions in the building sector [2,3,4]. Building codes and regulations have been developed and implemented for both new and existing buildings. In addition, considerable attention has focused on the development of energy-efficient buildings, green buildings, net-zero-energy buildings, energy performance certifications, labeling programs, etc. [5,6].
Building materials account for a large proportion of energy consumption in building construction. Therefore, the amount of energy consumed by materials is essential for developing and evaluating energy-efficient buildings, green buildings, green urban areas, and green construction technologies [7,8,9]. Clearly, building materials play an important role in determining the energy footprint of a building. To save energy, it is very important to choose suitable building materials right from the design stage. Many developed countries are focusing on building testing, rating, and labeling programs for building materials. Korea, for example, has now adopted a national testing system [10]. In the United States, different building materials may go through different testing, certification, and labeling processes by independent associations; for example, the U.S. Environmental Protection Agency will issue an Energy Star label for windows with National Fenestration Rating council (NFRC) labels [11]. In Europe, many labeling and certification programs for energy-saving building materials have been issued [12]. This has been significantly effective in reducing energy consumption in buildings, leading to the large increase in the number of energy-efficient buildings. In contrast, most developing countries have their own building energy policies, although the testing, rating, and labeling systems to assess the energy performance of building materials are still limited.
According to the Ministry of Construction, the growth rate of the construction industry in Vietnam increased by approximately 3.65% in the first six months of 2022 compared with the same period in 2021 [13]. The national urbanization rate was approximately 41%, and the average housing area reached approximately 25.2 m2 of floorspace per person [13].
It has therefore become necessary to find solutions, apply new materials, recycle materials, and utilize sustainable and eco-friendly building materials to minimize the negative impacts of the construction industry on the environment and on people’s lives.
As a result of Vietnam’s rapid economic development, residents’ lifestyles and needs are changing, and new building types are being introduced, using materials, structures, and supply systems not previously common in Vietnam. The materials are being exposed to new indoor conditions, while the outdoor climate is extremely warm and humid.
Efforts to save energy and conserve resources are urgently needed as national and global policymakers identify resource shortages, secure energy, pollution, and climate change as pressing issues. The construction sector, with its material flows (e.g., cement demand in Vietnam increased by 66% between 2015 and 2020 [14]) and rising energy demands (e.g., a tripling of electricity demand by 2030 compared with 2015 levels [15]), significantly contributes to these problems in Vietnam, and indeed, in most countries around the world.
In this regard, the use of materials such as unburned bricks for walls is currently being introduced in the Vietnamese construction industry in order to reduce energy and pollution through the production and consumption of arable land for the production of clay. Masonry blocks made of alternative materials, such as aerated concrete blocks and concrete blocks, are being advertised as substitutes. However, such new materials require adapted technologies and processing and integration into the building system in order to become a permanent and sustainable substitute for the technologies already established in the marketplace. In particular, moisture protection is of great importance in this context [16].
The failure of such new applications, for example, cracks in plaster or moisture ingress, will discredit such sustainable construction practice and is therefore detrimental to sustainable development. However, at present, there is insufficient knowledge of the physical building properties or capabilities of the Vietnamese construction industry. In fact, there is an urgent need for major studies into the development of infrastructure for the study of new materials, their physical behavior, and their technical application in order to prevent new, more resource-efficient technologies from being discredited in the market through any malfunctioning, thereby resulting in premature failure. Although new building energy codes have been introduced, the calculation tools, checklists, and other means of support for architects and engineers are still missing. Around 1200 materials can be used in energy-efficient buildings, according to the building material consumption survey conducted in 2020 by the Vietnam Institute for Building Materials. However, the values of essential properties for energy saving and other physical building assessments are still missing and are not available in Vietnam.
In this study, the need for the strategic development of technical infrastructure to promote sustainable construction practice was identified as a key objective. The key elements include reviewing the building energy efficiency policies in Vietnam and developing a comprehensive laboratory concept for the installation of instruments, procedures, and test standards for the characterization and research of energy-efficient building materials and construction products. One focus of the empirical research was to investigate the legal regulatory framework for energy-efficient, resource-efficient, and sustainable construction. The essential material tests necessary for the effective implementation of basic energy standards were identified and prioritized. Based on this, it became clear which test equipment was needed to implement energy standards. Through a strategic implementation plan for research and testing facilities, the relevant material properties (e.g., thermal conductivity and moisture absorption) for use in the Vietnamese construction industry have been determined.

2. Methodology

The methodology is described in this section. Figure 1 presents the study procedure.
(i)
An overview
A literature review was performed in this part.
(ii)
Location of the study
The study was conducted) in Hanoi, Vietnam. In the exiting VIBM rooms, the measuring and testing equipment was set up to determine the basic materials’ properties required for the application of Vietnamese energy efficiency regulations and to determine which are relevant for performance-oriented design (e.g., simulation studies).
(iii)
Selection of criteria and material specifications
The criteria and material specifications in planning practice were determined through analysis of planning data and a survey among the relevant stakeholders. The selected criteria were those required in energy regulations in Vietnam with regard to thermal and moisture protection and durability, taking into account the desired room climate. These material parameters were then adopted as the basis for the laboratory concept to be developed.
(iv)
Selection of measuring equipment and applied standards
All the necessary test equipment and test methods were precisely identified using measurement ranges, measurement accuracies, and test boundary conditions.
(v)
Build an energy-saving laboratory
The findings from the construction of two building physics laboratories in Vietnam were scaled up to simulate the possible physical infrastructure for further testing and research, and the approach for implementing such a facility was developed.
(vi)
Training to improve testing capacity for staff
The Vietnamese researchers and laboratory staffs were trained in Germany and laboratory personnel from Germany visited the locations in Vietnam to exchange experience and further education. A comparative investigation between the German and the Vietnamese laboratories was performed to validate the new measuring equipment.

3. Current Development and Policy

3.1. Current Policies Related to Energy-Saving Building Materials in Vietnam

All countries around the world, including Vietnam, are responsible for implementing energy-saving measures and greenhouse gas emission reductions in response to climate change. To reduce energy consumption in the building sector, the Vietnamese government has introduced various policies related to economical and energy requirements:
  • The Law on the Economic and Efficient Use of Energy No.50/2010/QH12 requires methodologies for the economical and efficient use of energy in construction activities [17].
  • Decision No.1266/QD-TTg was issued in August 2020 concerning the Strategy for the Development of Building Materials in Vietnam for 2021–2030, with objectives to work towards by 2050. It emphasized the importance of the efficient use of natural resources, saving energy and raw materials, and minimizing the environmental impact of the mining process for the production of building materials and products [18]. This aligns with the global response to climate change in terms of targeting building materials to reduce greenhouse gas emissions and conserve natural resources.
  • In the national technical regulation on energy efficiency in buildings in Vietnam-QCVN09:2017/BXD, the requirements are for (a) the thermal resistance, R0, of the opaque part, i.e., exterior walls above ground level (opaque parts of the walls) of the air-conditioned spaces should maintain a minimum overall thermal resistance value, R0, not smaller than 0.56 m2K/W, and flat roofs and roofs with a gradient of less than 15 degrees placed directly above the air-conditioned spaces should maintain a minimum overall thermal resistance value, R0min, not smaller than 1.00 m2K/W; (b) for construction and installation products applied in wall structures and building roofs, the thermal conductivity coefficient, λ, of materials should be announced; and (c) in the requirements for the transparent parts (glazing), maximum SHGC values should comply with the values specified in Table 1 [19].
  • Decision No.280/QĐ-TTg was issued in March 2019 by the Prime Minister, approving the National Program on Economic and efficient use of energy in the period of 2019–2030 that clearly defines the targets up to 2025, such as (a) achieving energy-savings levels from 5.0% to 7.0% of the total national energy consumption from 2019 to 2025; (b) achieving 80 construction projects (150 construction projects up to 2030) that are certified as green constructions, using economic and efficient energy; (c) building one data warehouse information center for energy and at least two national training centers for using economical and efficient energy, one energy-efficient urban model, five demonstration models on investment loans for projects relevant to economical and efficient energy use, and two energy-efficiency-testing laboratories. Up to 2030, energy labels will be implemented for at least 50% of all types of building material products with insulation requirements [20].
  • Circular 01/2018/TT-BXD relevant to the required criteria for the development of urban green construction was issued in January 2018 [21].
  • National standard TCVN 9258:2012 on heat protection for houses—design guidelines and Standard TCVN 4605–1998 for cladding structures—design standards for the thermal insulation of cover structures for buildings and constructions with microclimate conditions were issued [22,23].

3.2. Current Situation of the Utilization of Energy-Saving Materials in Vietnam

In 2019, Vietnam had over 1600 production facilities of unburned building materials, with a total design capacity of about 10.2 billion standard pellets/year (nearly 30% of the total design capacity of the building materials production line) [24]. Popular unburned building materials include concrete bricks, autoclaved aerated concrete bricks, autoclaved aerated concrete slabs, and precast hollow concrete wall panels. Actual production/consumption output reached 4.83 billion standard unburned bricks [24].
Many construction products and materials with resource-efficient, environmentally friendly, and energy-saving features are currently available on the Vietnamese market. The state encourages and supports numerous projects for the production of energy-saving building materials, such as low-E glass and unburned bricks. Generally, the research, production, testing, and widespread use of products and materials with energy-saving and environmentally friendly features are largely the result of companies’ efforts to produce and distribute such products and building materials. However, there is a lack of comprehensive activities by the state and credit institutions to support businesses in this field. In particular, there has been no focus on the testing, rating, and labeling of these materials because of the insufficient capacity to test the hygrothermal properties of building materials (e.g., thermal conductivity, moisture absorption, etc.). Some enterprises need to send products to foreign testing laboratories, which costs a lot of time and money. Therefore, there is an urgent need to build a material testing laboratory with sufficient capacity to test, evaluate and label energy-saving building materials and construction products. This falls in line with global development trends.

4. Challenges and Opportunities

In 2005, the governmental decree 102/2003/ND-CP on the economic and efficient use of energy was issued. Nearly 20 years later, we have seen some positive results. However, a lot of limitations and challenges remain, concerning the implementation of the contents of economical and efficient use of energy in the fields of construction, production, and in particular, in the use of building materials with energy-saving features [25]:
  • It is not easy to access specific financial incentives for projects that produce energy-saving and environmentally friendly building materials and products.
  • There is a lack of mandatory or recommended regulations for the assessment, certification, and energy labeling of construction products and building materials.
  • There is still inadequate awareness and interest by stakeholders such as investors, construction contractors, operation management units, and users in economical and efficient energy use.
  • There are no mandatory regulations for new construction or renovation works to meet green building standards.
The above limitations and challenges, combined with pressures of the rising prices of raw material and energy, limited supply, as well as firm government commitments on environmental protection, energy saving, and reducing greenhouse gas emissions, create significant opportunities to vigorously develop energy-saving and environmentally friendly products, goods, and building materials to be used in energy-efficient buildings and constructions, green buildings, and low-emission buildings.
As people’s living standards and incomes improve, it is becoming more vital to ensure healthy and comfortable conditions within a building. Technical requirements in line with indoor air quality regulations and standards have been developed to guarantee comfort and limit the impact of microorganisms and mold. Their application encourages research, development, production, and the use of construction materials with energy saving, economical, resource efficiency, and environmentally friendly features to reduce emissions and ensure the health of users. The process of integration and globalization, and the participation in linkage chains, supply chains, and global value chains, place pressure on enterprises producing and distributing products, building materials, as well as investors. The investment and operation management units of construction works must comply with and apply criteria and standards and perform the assessment, certification, energy labeling, and eco-labeling of construction materials used in the building.

5. Study on the Facilities and Equipment for Testing Energy-Saving Materials in Vietnam

Determining the heat transfer, moisture transfer, and durability properties of materials plays a significant role in energy-efficient and economical buildings worldwide, including Vietnam [26,27,28]. Therefore, it is vital to determine the type of material suitable for intended use in the project. Furthermore, following the trend of using innovative materials and energy-saving materials, along with the mandatory implementation of QCVN 09:2017/BXD in the near future, there will be a greater need to research and test heat and moisture transfer features, as well as the durability of building materials utilized for suitable selection to the actual climatic conditions. Therefore, it is essential to research and improve testing capacities in this field, new to Vietnam, to bring about long-term improvements.
A laboratory for testing building physics properties has been established to determine the basic materials’ properties required for the application of Vietnamese energy efficiency regulations and to determine which are relevant for performance-oriented design, necessary for a simulation study. All the necessary test equipment and test methods have been precisely identified using measurement ranges, measurement accuracies, and test boundary conditions.

5.1. Necessary Material Parameters for the Energy Code

  • Thermal transmittance (U0-value)/total thermal resistance (R0-value)
R0-value/heat conductivity, λ
The total thermal resistance describes the resistance of a building to heat flow when a temperature difference is present at the component boundaries. The R0-value is the reciprocal of the U0-value and is calculated from the thermal conductivities of individual component layers and the transition resistances at the surfaces. To determine the R0-value, it is necessary to know the installation situation to determine the surface resistance. Independent of the installation situation, the thermal conductivity of building materials used in the component must be determined. The thermal conductivity is a material parameter that indicates the heat flow at a 1 K temperature difference of a 1 m thick sample. Determination of the thermal conductivity by means of a plate device is described in national and international standards, which will be indicated later in this research. For the measurement of the characteristic value, measuring equipment for determining the material thickness must be available. Likewise, both a heating cabinet and a climatic cabinet are necessary for preconditioning. Depending on the plate equipment used, material specimens with dimensions of 0.3 m × 0.3 m to 1.0 m × 1.0 m must be prepared. Depending on the material, a bandsaw may be useful for cutting the material specimens. To prevent the influence of strong temperature and air humidity fluctuations in the laboratory room, the room in which the measurement with the plate instrument takes place should be air-conditioned. The thermal conductivity of a material depends on the temperature and the moisture content, and can also be determined as a function depending on these influences during measurements. The thermal conductivity was determined in laboratory A1 (Figure 1), as well as in the extended laboratory, A2 (Figure 2), with guarded hot plate devices No.2 and No.3, respectively.
U0-value
The thermal transmittance (U0-value) is a measure of the heat transfer through a building component and is used to determine the transmission heat loss/gain of a building component. The value can either be calculated from the thermal resistance of the individual materials and the surface resistance or determined directly via a hotbox method.
U 0 = 1 R 0   ( m 2 · K / W )
The hotbox method is usually employed to determine the U-value of inhomogeneous structures, such as windows and doors. The test setup requires two separate air-conditioned rooms with an opening in the partition wall for the installation of a test specimen. Thermal transmittance is determined in two steps. In the first step, the test stand-related surface resistances are determined using a calibration plate with known thermal properties. In the second step, the thermal transmittance of the test specimen is determined. The size of the test rig depends on the size of the test specimen to be measured. Test stands for windows and doors should have a base area of approximately 5.0 m × 5.0 m. Figure 2 shows a test rig with a floor space of 25 m2. The U0-value using the hotbox method could only be determined in the extended laboratory A2 No.10 (Figure 2).
  • Total energy transmittance g-value
The total energy transmittance, g, is the sum of the direct radiation transmittance, τ, and the secondary heat loss rate, qi, of the glazing to the inside. The latter is caused by heat transfer due to convection and long-wave IR radiation of the proportion of incident radiation absorbed by the glazing [DIN EN 410:201104] [29]. A spectrometer can be used to determine the g-value for simple glass samples. Here, radiation properties such as the direct radiation transmittance, direct radiation reflectance, and direct radiation absorptance are determined. From these characteristics, both the primary and secondary energy inputs for single and multiple glazing can be determined. For special components, such as glazing with integrated solar shading or curved components, the g-value can be determined using the calorimetric method. For this method, the test specimen is exposed to artificial solar radiation in the range 300 to 900 W/m2, and an energy balance is carried out for measuring the space behind the specimen for defined ambient conditions.
A No.1 UV/VIS/NIR spectrometer device (Shimadzu, Kyoto, Japan) was used to determine the total energy transmission g-value of smaller samples (600 mm × 600 mm) in the simple laboratory, A1. Solar simulator No.12 (Figure 3) was utilized to determine larger samples in the extended laboratory, A2.

5.2. Characteristic Values for Energy Optimization

  • Air permeability of building components
An airtight building envelope can prevent energy input/loss through convective heat flows in leakage areas. The connection of joints should be designed to ensure the lowest possible air permeability, particularly in the case of openings such as windows and doors, but also in the case of structural connections of different building components. The air permeability of building components is defined by the air volume flow rate that passes through the leakages of a building component over time at an existing pressure difference. Depending on the standard, this value can refer to the length of a connection joint or the area of a component. To determine the air permeability, an airtight test stand is required in which an opening is provided for the test specimen. A fan is used to generate positive or negative pressure on the test specimen. Air permeability as a function of the applied pressure difference is determined from the measured values of a flow meter and a pressure gauge. Independent of the laboratory measurement, mobile devices can also be used to determine the air permeability of entire buildings. This is advantageous after completion of the airtight building envelope in the shell state, because it allows the performance of the connections to be checked and possibly improved. For air permeability, an air exchange rate of 1/h of the building volume at a pressure difference of 50 Pascal is often determined. An air permeability test of components can be performed in extended laboratory A2 in leak test stand No.11 (Figure 2).
  • Radiation characteristics
In addition to the total energy transmittance, radiation-related characteristic values can be determined for transparent as well as opaque components, which are helpful for energy optimization.
  • Light transmission factor
From the spectral data, which are also determined by means of a spectrometer when determining the g-value, the light transmittance for standard light, D65, can be calculated. This value can be used in living and working spaces to optimize the use of daylight and thus reduce energy consumption when using artificial light. Light transmittance can also be determined with UV/VIS/NIR spectrometer No.1 in laboratory A1 and extended laboratory A2 (Figure 2).
  • Thermal emissivity
Emissivity is a wavelength-dependent quantity and a measure of the radiation exchange of a material with its environment. In building physics, the thermal long-wave radiation range is of particular importance. This characteristic value can be used, for example, to calculate the long-wave radiation of facade and roof surfaces. In the interior, thermal emissivity is a necessary parameter for assessing the operative temperature, and thus is a factor for evaluating comfort. The thermal emissivity can be determined with emissometer No.2 in both A1 and A2 laboratories (Figure 2 and Figure 3).

5.3. Additional Hygrothermal Parameters for the Research and Development of Damage-Free Buildings

  • Temperature- and moisture-dependent thermal conductivity
As already described, thermal conductivity is a parameter that describes the heat transport through a material. This parameter is strongly dependent on the water content as well as the prevailing temperature. When evaluating a component, simulation programs make it possible to consider the thermal conductivities dependent on the ambient conditions. The specific thermal conductivities can also be determined with the aid of plate instruments. Similarly to simple thermal conductivity, temperature- and humidity-dependent thermal conductivity can also be determined in the A1 and A2 laboratories (Figure 2 and Figure 3). Plate instruments No.2 and No.3 are required for this purpose.
  • Heat capacity
Heat capacity is a quantity that reflects the heat storage capacity of a material. In the laboratory, this value is determined by dynamic differential calorimetry. In simulation programs, heat capacity is included in calculations of heat transfer and is a factor responsible for the phase shift of heat transfer under transient boundary conditions. When calculating the energy consumption of a building, this parameter can be used to determine the effective heat storage capacity, which is a building-specific variable that describes the amount of heat that can be absorbed by the interior building components. The heat capacity could be determined in both laboratories A1 and A2 with the necessary measuring device (Figure 2 and Figure 3). Space for such a measuring device is provided under No.8.
  • Bulk density
Bulk density is the ratio of the mass of a specimen to its total volume. It is a basic characteristic value that is necessary for a number of calculations. Many other characteristic values refer to the bulk density of a material. In simulation calculations, for example, bulk density is used to convert the mass-specific heat capacity into the volume-specific heat capacity or to display water contents in mass percentages. Bulk density is determined after drying with the aid of vacuum water absorption and weighing an impregnated specimen. To determine bulk density, space is provided in both laboratories A1 and A2 for the necessary measuring equipment, such as balances, under No. 5 (Figure 2 and Figure 3).
  • Porosity
Porosity is the ratio of the volume of a specimen to the volume of the pores in [m3/m3]. In a porous material, pores can be in contact with ambient air, but they can also be cavities closed off on all sides. Accordingly, they are usually described by “open” or “closed” porosity. Open porosity is determined by vacuum water absorption in the same procedure as the bulk density. By crushing and weighing a sample, it is possible to infer the pure density, and thus, also the total porosity. Open porosity can be used to infer the maximum water content of a material. However, because most simulation calculations are not very sensitive to the maximum water content, the value is of little importance. For the determination of porosity, areas No.5 and No.8 are provided in laboratories A1 and A2, respectively (Figure 2 and Figure 3).
  • Water vapor diffusion resistance number (µ-value)
The µ-value indicates the factor by which the diffusion resistance in the material is higher than in still air. This characteristic value is necessary to determine moisture penetration via diffusion processes when a partial pressure difference is present and is, therefore, an essential characteristic value for assessing the freedom from the damage of a building structure. In the laboratory, this value is determined by means of the dry/wet cup method. The specimen is exposed to a water vapor partial pressure difference by placing it in an airtight container with a desiccant or an aqueous saturated solution and storing it at a constant climate. The amount of diffused water vapor can be determined by weighing the test setup at regular intervals. Water vapor diffusion resistance can be determined in both laboratories A1 and A2 with the use of climatic chamber No.4 (Figure 2 and Figure 3).
  • Moisture storage function
A porous hygroscopic substance binds water molecules on the inner surfaces of its polymer system until it reaches an equilibrium water content corresponding to the humidity state of the surrounding air. This relationship between the relative humidity and the water content can be represented in a so-called sorption isotherm (moisture storage function), which can be divided into two areas: (i) sorption range, hygroscopic range, where some of the water molecules in the pore air are bound to the pore walls by absorption and accumulate there with increasing air humidity, first as single molecules, then as molecular groups, then as monomolecular layers, and finally as multimolecular layers consisting of several molecular layers, so that the equilibrium water content increases approximately in proportion to the air humidity; (ii) capillary water area, over-hygroscopic area, in which from a relative humidity of approximately 0.6 to 0.8, additional condensation phenomena occur due to the reduction in the saturation vapor pressure in fine capillaries, resulting in a significant increase in the equilibrium humidity. The pores then contain not only absorptive bound water, but also unbound liquid water.
In simulations, the moisture storage function helps to make statements about the water content, and thus, also about the thermal conductivity of a material. In the sorption range (up to ≈ 0.9 RH), the function is determined by storing material samples in a climatic chamber at constant temperature and relative humidity and determining the water content gravimetrically. In the capillary water range (above 0.95 RH), a suction stress measurement is carried out with suction stress apparatus. Characteristic values of the moisture storage function can also be determined using climate chambers No.4 and No.9 (Figure 2 and Figure 3).
  • Water absorption coefficient
The water absorption coefficient of a material is defined by the water absorption per area and time. Depending on where a building material is used, the water absorption can be determined according to different standards:
-
Determination of the water absorption coefficient during partial immersion (capillary water absorption);
-
Water absorption during long-term immersion;
-
Water absorption by diffusion.
The determination of water absorption can be helpful in various areas. Among other things, the water absorption coefficient can be used to evaluate the rain protection effect of a facade or to classify building materials for use in components in contact with the ground. The water absorption can be determined in both laboratories A1 and A2 with the help of trolley No.5 and the dip tanks under No.6 (Figure 2 and Figure 3).
  • Weather data
For the calculation of heating and cooling loads of a building, the boundary conditions of the adjacent temperatures and weather conditions are decisive in addition to the characteristic values of building physics. For the climate inside the building, relevant standards such as DIN 4108, EN 15026, ISO 13788, and ASH-RAE 160 specify characteristic values for the indoor climate as a function of the respective outdoor climate [30,31,32,33]. The outdoor climate is taken from the measured data for the test reference year in simulation programs for calculating building energy consumption. In order to obtain reliable weather data for a region under consideration, several weather stations are necessary. Depending on the configuration of the weather station, the following weather data can be recorded:
-
Direct and diffuse solar radiation in W/m2;
-
Temperature in °C;
-
Relative humidity in %;
-
Wind direction and speed in m/s;
-
Wind direction;
-
Air pressure hPa;
-
Rainfall l/m2h.
For a simple energy consumption calculation, the parameters of temperature and solar radiation are important. The outside temperature, in connection with the thermal conductivity or the U-value of a building component, is decisive for calculation of the transmission heat loss, and is thus directly included in calculation of the heating energy demand. The solar radiation, on the other hand, is used in combination with the g-value to determine the energy input via glass surfaces, and thus, the necessary cooling load of a building. Other weather data are especially necessary for the evaluation of damage-free constructions. For example, simulations using the amount of rain and the wind direction, as well as the water absorption coefficient, can be used to make a statement about the water absorption on a facade surface, and thus, also about the resulting change in thermal conductivity. The relevance of the weather data is to be judged depending on the focus of the observation. Thus, maximum values can also be estimated and determined for the assessment of a worst-case scenario.

5.4. Proposal for a Simple (A1) and Advanced (A2) Laboratory

In this study, two proposals for a smaller (A1) and an advanced laboratory (A2) with the appropriate equipment have been developed to determine the necessary characteristic values required for calculations of the QCVN 09:2017/BXD national technical regulation on energy-efficient buildings in Vietnam. Version A1 shows a smaller laboratory with a floor space of 190 m2, with all the necessary measuring equipment to determine the basic building physics parameters. Costs of approximately EUR 500,000 must be calculated for the laboratory’s equipment. All rooms where measurements are carried out must have an air conditioning system to maintain stable climatic conditions. In addition to the laboratory floor plan, office equipment space must be planned. Laboratory proposal A1 is intended for measurements on smaller material samples. Therefore, an average room height of 3–4 m is sufficient for the laboratory rooms. Possible characteristic value determination with a simple laboratory setup is proposed, as shown in Table 2 and the floor plan in Figure 2.
In the second version, A2, the small laboratory is extended with a larger hall of 170 m2, in which additional characteristic values can be determined. The facilities in laboratory A2 also allow larger material samples and components to be measured and their characteristic values to be determined (see Table 3 and Figure 3). The additional hall should have a minimum height of 7 m and preferably be equipped with an overhead crane to install heavy components. In addition to the costs of the simple laboratory, a further EUR 850,000 should be calculated for the extended laboratory’s equipment. All cost estimates are only for the technical equipment and not for the buildings.

6. Training and Improving Test Capacity for Staff

The Vietnamese researchers and laboratory staffs were trained in Germany at, and laboratory personnel from Germany visited the locations in Vietnam to exchange experience and further education. Following the implementation and calibration of the laboratory measurement equipment, several relevant materials and material systems were selected for comparative testing. The selected materials were tested in Vietnam and then sent to the -Germany, where the tests were repeated nondestructively on the same samples. Comparing the results allowed potential problems to be identified and resolved through bilateral discussions. This ensures that standard quality standards are adhered to, and the results will be internationally comparable. At the moment, this new laboratory is the only one in Vietnam.

7. Conclusions and Policy Implications

In this study, the governance framework on energy efficiency building materials in Vietnam has been introduced, including government decrees and technical standards. Then, a laboratory concept for characteristic value determination, in accordance with Vietnamese energy standards and building physics materials, components, and building research, was developed and implemented in Hanoi, Vietnam. This research is necessary for the complete assessment of building materials and construction products for the present and future generation of energy-efficient buildings and sustainable buildings. No other comparable studies have been published; therefore, this research has great practical and scientific significance. This academic knowledge will greatly contribute to developing new energy-saving materials, energy-efficient buildings, and sustainable development to help achieve the goal of zero emissions by 2050. Using this research, Vietnam and other developing countries that do not have specific expertise and tradition in this field will also be able to improve their systems for testing, rating, and labeling building materials for energy performance, towards sustainability in countries. Moreover, clear information on the energy performance of building materials by testing, rating, and labeling systems will support the development of energy-efficient and sustainable buildings by helping code officials to easily verify that this material matches the code-compliant design.
Several policy implications can be determined from our results. First, from the results of the overview regulations, policymakers can identify which policies and regulations are missing in order to develop, supplement, and complete the regulation framework for the implementation of saving energy in the building. Secondly, research on the development of laboratory concepts with all necessary equipment is a very good tool for implementing energy efficiency regulations in buildings, such as energy efficiency standards, regulations, and labeling programs. Finally, our results are a very good reference for policymakers from developing countries such as Vietnam to learn how to develop energy-saving mechanisms in buildings, sustainable development, moving towards the goal of zero emissions by 2025.

Author Contributions

T.S.L.: conceptualization, methodology, writing—original draft preparation; A.Z.: data collection and supervision; H.K.: supervision; D.S.: writing—review and editing and project leader; C.C.L., T.H.L., T.T.L. and T.T.N.: project administration. All authors have read and agreed to the published version of the manuscript.

Funding

The CAMaRSEC project is funded within the CLIENT II program “CLIENT II—International Partnerships for Sustainable Innovations” from the German Ministry of Education and Research (BMBF) under funding code 01LZ1804.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Acknowledgments

The research presented in this publication was supported by the Vietnamese Ministry of Construction and the CAMaRSEC project.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Transition to Sustainable Buildings—Analysis. Available online: https://www.iea.org/reports/transition-to-sustainable-buildings (accessed on 7 August 2023).
  2. Jollands, N.; Waide, P.; Ellis, M.; Onoda, T.; Laustsen, J.; Tanaka, K.; de T’Serclaes, P.; Barnsley, I.; Bradley, R.; Meier, A. The 25 IEA Energy Efficiency Policy Recommendations to the G8 Gleneagles Plan of Action. Energy Policy 2010, 38, 6409–6418. [Google Scholar] [CrossRef]
  3. Nearly Zero-Energy Buildings. Available online: https://energy.ec.europa.eu/topics/energy-efficiency/energy-efficient-buildings/nearly-zero-energy-buildings_en (accessed on 7 August 2023).
  4. Kaya, D.; Çanka Kılıç, F.; Öztürk, H.H. Energy Performance Certificate. In Energy Management and Energy Efficiency in Industry: Practical Examples; Kaya, D., Çanka Kılıç, F., Öztürk, H.H., Eds.; Green Energy and Technology; Springer International Publishing: Cham, Switzerland, 2021; pp. 73–79. ISBN 978-3-030-25995-2. [Google Scholar]
  5. Jaysawal, R.K.; Chakraborty, S.; Elangovan, D.; Padmanaban, S. Concept of Net Zero Energy Buildings (NZEB)—A Literature Review. Clean. Eng. Technol. 2022, 11, 100582. [Google Scholar] [CrossRef]
  6. Pérez-Lombard, L.; Ortiz, J.; González, R.; Maestre, I.R. A review of benchmarking, rating and labelling concepts within the framework of building energy certification schemes. Energy Build. 2009, 41, 272–278. [Google Scholar] [CrossRef]
  7. Cabeza, L.F.; Barreneche, C.; Miró, L.; Martínez, M.; Fernández, A.I.; Urge-Vorsatz, D. Affordable Construction towards Sustainable Buildings: Review on Embodied Energy in Building Materials. Curr. Opin. Environ. Sustain. 2013, 5, 229–236. [Google Scholar] [CrossRef]
  8. Usta, P.; Zengin, B. The Energy Impact of Building Materials in Residential Buildings in Turkey. Materials 2021, 14, 2793. [Google Scholar] [CrossRef] [PubMed]
  9. Yu, Y.; Cheng, J.; You, S.; Ye, T.; Zhang, H.; Fan, M.; Wei, S.; Liu, S. Effect of Implementing Building Energy Efficiency Labeling in China: A Case Study in Shanghai. Energy Policy 2019, 133, 110898. [Google Scholar] [CrossRef]
  10. Park, D.J.; Yu, K.H.; Yoon, Y.S.; Kim, K.H.; Kim, S.S. Analysis of a Building Energy Efficiency Certification System in Korea. Sustainability 2015, 7, 16086–16107. [Google Scholar] [CrossRef]
  11. National Fenestration Rating Council. 2016. Available online: https://www.nfrc.org/wp-content/uploads/2016/08/NFRC-713-2016_E0A0-final.pdf (accessed on 6 September 2023).
  12. Economidou, M.; Atanasiu, B.; Staniaszek, D.; Maio, J.; Nolte, I.; Rapf, O.; Laustsen, J.; Ruyssevelt, P.; Strong, D.; Zinetti, S. Europe’s Buildings under the Microscope. A Country-by-Country Review of the Energy Performance of Buildings; Buildings Performance Institute Europe BPIE: Brussels, Belgium, 2011; ISBN 978-94-91143-01-4. [Google Scholar]
  13. Thanh.N., Tạp chí xây dựng. 2022. Available online: https://tapchixaydung.vn/6-thang-dau-nam-nganh-xay-dung-tang-truong-365-20201224000012275.html (accessed on 3 November 2022).
  14. Vietnamese Cement Annual Report. 2021. Available online: https://www.stockbiz.vn/Handlers/DownloadReport.ashx?ReportID=11961 (accessed on 6 September 2023).
  15. Asian Development Bank and Asian Development Bank Institute, Viet Nam: Energy Sector Assessment, Strategy, and Road Map. 2015. Available online: https://www.adb.org/sites/default/files/institutional-document/178616/vie-energy-road-map.pdf (accessed on 6 June 2023).
  16. Möller, M. Thermo-Hygric Shape Changes and Residual Stresses of Natural and Artificial Bricks; Report for University of Stuttgart; University of Stuttgart: Stuttgart, Germany, 1993. [Google Scholar]
  17. Law on Economical and Efficient Use of Energy (50/2010/QH12).|UNEP Law and Environment Assistance Platform. Available online: https://leap.unep.org/countries/vn/national-legislation/law-economical-and-efficient-use-energy-502010qh12 (accessed on 6 June 2023).
  18. Decision No. 1266/QD-TTg 2020 Strategy for Development of Building Materials in 2021–2030. Available online: https://english.luatvietnam.vn/decision-no-1266-qd-ttg-approving-the-strategy-for-development-of-vietnams-building-materials-for-the-20-189217-doc1.html (accessed on 5 June 2023).
  19. National Technical Regulation on Energy Efficiency Buildings|ESCAP Policy Documents Management. Available online: https://policy.asiapacificenergy.org/node/1107 (accessed on 6 June 2023).
  20. Decision No. 280/QD-TTg Dated 13 March 2019 on Approval for National Program for Thrifty and Efficient Use of Energy for the Period of 2019–2030 280/QD-TTg,Quyết Định 280. 2019. Available online: https://lawnet.vn/en/vb/Decision-280-QD-TTg-2019-approval-for-national-program-for-thrifty-and-efficient-use-of-energy-6E098.html (accessed on 6 June 2023).
  21. Circular No. 01/2018/TT-BXD Dated 5 January 2018 on Urban Green Growth Indicators 01/2018/TT-BXD,Thông Tư 01. 2018. Available online: https://lawnet.vn/en/vb/Circular-01-2018-TT-BXD-on-urban-green-growth-indicators-5B69A.html (accessed on 6 June 2023).
  22. Tiêu Chuẩn Quốc Gia TCVN 9258:2012 về Chống Nóng Cho Nhà ở—Hướng Dẫn Thiết Kế. Available online: https://vanbanphapluat.co/tcvn-9258-2012-chong-nong-cho-nha-o-chi-dan-thiet-ke (accessed on 6 June 2023).
  23. Tiêu Chuẩn Việt Nam TCVN 4605:1988 về Kỹ Thuật Nhiệt—Kết Cấu Ngăn Che—Tiêu Chuẩn Thiết Kế. Available online: https://vanbanphapluat.co/tcvn-4605-1988-ky-thuat-nhiet-ket-cau-ngan-che-tieu-chuan-thiet-ke (accessed on 6 June 2023).
  24. Tin Bộ Tài Chính. Available online: https://mof.gov.vn/webcenter/portal/btcvn/pages_r/l/tin-bo-tai-chinh?dDocName=MOFUCM222793 (accessed on 7 June 2023).
  25. Nghị Định 102/2003/NĐ-CP Sử Dụng Năng Lượng Tiết Kiệm Hiệu Quả. Available online: https://thuvienphapluat.vn/van-ban/Tai-nguyen-Moi-truong/Nghi-dinh-102-2003-ND-CP-su-dung-nang-luong-tiet-kiem-hieu-qua-51315.aspx (accessed on 6 June 2023).
  26. Liu, F.; Jia, B.; Chen, B.; Geng, W. Moisture Transfer in Building Envelope and Influence on Heat Transfer. Procedia Eng. 2017, 205, 3654–3661. [Google Scholar] [CrossRef]
  27. Wang, Y.; Tian, Y.; Zhao, Z.; Wang, D.; Liu, Y.; Liu, J. Effect of Moisture Transfer on Heat Transfer through Exterior Corners of Cooled Buildings in Hot and Humid Areas. J. Build. Eng. 2021, 43, 103160. [Google Scholar] [CrossRef]
  28. Wang, Y.; Ma, C.; Liu, Y.; Wang, D.; Liu, J. Effect of Moisture Migration and Phase Change on Effective Thermal Conductivity of Porous Building Materials. Int. J. Heat Mass Transf. 2018, 125, 330–342. [Google Scholar] [CrossRef]
  29. DIN EN 410:2011-04; Glass in Building—Determination of Luminous and Solar Characteristics of Glazing. German Institute for Standardization: Berlin, Germany, 2011.
  30. DIN 4108:2021; Thermal Insulation and Energy Economy in Buildings. German Institute for Standardization: Berlin, Germany, 2011.
  31. EN 15026:2023; Hygrothermal Performance of Building Components and Building Elements—Assessment of Moisture Transfer by Numerical Simulation. European Committee for Standardization: Brussels, Belgium, 2023.
  32. ISO 13788:2012; Hygrothermal Performance of Building Components and Building Elements—Internal Surface Temperature to Avoid Critical Surface Humidity and Interstitial Condensation—Calculation Methods. International Organization for Standardization: Geneva, Switzerland, 2012.
  33. ASH-RAE 160:2021; Criteria for Moisture-Control Design Analysis in Buildings. The American Society of Heating, Refrigerating and Air-Conditioning Engineers: Peachtree Corners, GA, USA, 2021.
  34. ISO 8302:1991; Thermal Insulation—Determination Of Steady-State Thermal Resistance and Related Properties—Guarded Hot Plate Apparatus. International Organization for Standardization: Geneva, Switzerland, 1991.
  35. ASTM C518; Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. American Society for Testing and Materials: West Conshohocken, PA, USA, 2021.
  36. EN 1946-3; Thermal Performance of Building Products and Components—Specific Criteria for the Assessment of Laboratories Measuring Heat Transfer Properties—Part 3: Measurements by Heat Flow Meter Method. European Committee for Standardization: Brussels, Belgium, 1999.
  37. EN 12664; Thermal Performance of Building Materials and Products—Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods—Dry and Moist Products of Medium and Low Thermal Resistance. European Committee for Standardization: Brussels, Belgium, 2001.
  38. EN 12667; Thermal Performance of Building Materials and Products—Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods—Products of High and Medium Thermal Resistance. European Committee for Standardization: Brussels, Belgium, 2001.
  39. EN 12939; Thermal Performance of Building Materials and Products—Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods—Thick Products of High and Medium Thermal Resistance. European Committee for Standardization: Brussels, Belgium, 2000.
  40. ASTM E1269-11; Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry. American Society for Testing and Materials: West Conshohocken, PA, USA, 2018.
  41. ASTM E2716-09; Standard Test Method for Determining Specific Heat Capacity by Sinusoidal Modulated Temperature Differential Scanning Calorimetry. American Society for Testing and Materials: West Conshohocken, PA, USA, 2014.
  42. EN ISO 11357-1; Plastics—Differential Scanning Calorimetry (DSC)—Part 1: General Principles. European Committee for Standardization: Brussels, Belgium, 2013.
  43. DIN 51007; Thermal Analysis—Differential Thermal Analysis (DTA) and Differential Scanning Calorimetry (DSC)—General Principles. German Institute for Standardization: Berlin, Germany, 2019.
  44. EN 1097-6; Tests for Mechanical and Physical Properties of Aggregates—Part 6: Determination of Particle Density and Water Absorption. European Committee for Standardization: Brussels, Belgium, 2022.
  45. EN 772-4; Methods of Test for Masonry Units—Part 4: Determination of Real and Bulk Density and of Total and Open Porosity for Natural Stone Masonry Units. European Committee for Standardization: Brussels, Belgium, 1998.
  46. EN 1936; Natural Stone Test Methods—Determination of Real Density and Apparent Density, and of Total and Open Porosity. European Committee for Standardization: Brussels, Belgium, 2006.
  47. EN ISO 12572; Hygrothermal Performance of Building Materials and Products—Determination of Water Vapour Transmission Properties—Cup Method (ISO 12572:2016). European Committee for Standardization: Brussels, Belgium, 2016.
  48. EN ISO 12571; Hygrothermal Performance of Building Materials and Products—Determination of Hygroscopic Sorption Properties (ISO 12571:2021). European Committee for Standardization: Brussels, Belgium, 2021.
  49. ISO 12570; Hygrothermal Performance of Building Materials and Products—Determination of Moisture Content by Drying at Elevated Temperature. International Organization for Standardization: Geneva, Switzerland, 2000.
  50. EN ISO 15148; Hygrothermal Performance of Building Materials and Products—Determination of Water Absorption Coefficient by Partial Immersion. European Committee for Standardization: Brussels, Belgium, 2002.
  51. EN 1015-18; Methods of Test for Mortar for Masonry—Part 18: Determination of Water Absorption Coefficient Due to Capillary Action of Hardened Mortar. European Committee for Standardization: Brussels, Belgium, 2002.
  52. DIN EN 772-11; Methods of Test for Masonry Units—Part 11: Determination of Water Absorption of Aggregate Concrete, Autoclaved Aerated Concrete, Manufactured Stone and Natural Stone Masonry Units Due to Capillary Action and the Initial Rate of Water Absorption of Clay Masonry Units. German Institute for Standardization: Berlin, Germany, 2011.
  53. EN ISO 16535; Thermal Insulating Products for Building Applications—Determination of Long-Term Water Absorption by Immersion (ISO 16535:2019). European Committee for Standardization: Brussels, Belgium, 2019.
  54. DIN EN ISO 12567-1; Thermal Performance of Windows and Doors—Determination of Thermal Transmittance by the Hot-Box Method Part 1: Complete Windows and Doors. German Institute for Standardization: Berlin, Germany, 2010.
  55. DIN EN ISO 12567-2; Thermal Performance of Windows and Doors—Determination of Thermal Transmittance by Hot Box Method—Part 2: Roof Windows and Other Projecting Windows. German Institute for Standardization: Berlin, Germany, 2005.
  56. DIN EN 12412-2; Thermal Performance of Windows and Doors—Determination of Thermal Transmittance by Hot Box Method—Part 2: Roof Windows and Other Projecting Windows. German Institute for Standardization: Berlin, Germany, 2005.
  57. DIN EN 12412-4; Thermal Performance of Windows, Doors and Shutters—Determination of Thermal Transmittance by Hot Box Method—Part 4: Roller Shutter Boxes. German Institute for Standardization: Berlin, Germany, 2003.
  58. DIN EN ISO 8990; Thermal Insulation—Determination of Steady-State Thermal Transmission Properties Using the Calibrated and Guarded Hot Boxes (ISO 8990:1994). German Institute for Standardization: Berlin, Germany, 1994.
  59. EN 12 114; Thermal Performance of Buildings—Air Permeability of Building Components and Building Elements—Laboratory Test Method. European Committee for Standardization: Brussels, Belgium, 2000.
  60. EN 12153; Curtain Walling—Air Permeability—Test Method. European Committee for Standardization: Brussels, Belgium, 2000.
  61. EN 1026; Windows and Doors—Air Permeability—Test Method. European Committee for Standardization: Brussels, Belgium, 2016.
  62. EN 12207; Windows and Doors—Air Permeability—Classification. European Committee for Standardization: Brussels, Belgium, 2016.
  63. EN 12427; Industrial, Commercial and Garage Doors and Gates—Air Permeability—Test Method. European Committee for Standardization: Brussels, Belgium, 2000.
  64. ISO 19467; Thermal Performance of Windows and Doors—Determination of Solar Heat Gain Coefficient Using Solar Simulator. International Organization for Standardization: Geneva, Switzerland, 2021.
Figure 1. The study procedure.
Figure 1. The study procedure.
Sustainability 15 15921 g001
Figure 2. Floor plan simple laboratory setup. 1. UV/VIS/NIR spectrometer: 2.7 m × 0.9 m, 2. Guarded hot plate for 90 × 90 sample: 2.5 m × 2.5 m, 3. Guarded hot plate for 30 × 30 sample: 1.0 m × 1.0 m, 4. Double climate chamber walk-in: 2.5 m × 2.8 m, 5. Scales with different capacity: 4.0 m × 0.6 m, 6. Water basin: 1.5 m × 2.5 m, 7. Heating cabinet for drying specimens: 1.5 m × 1.5 m, 8. Space for different apparatuses: 1.4 m × 0.6 m, 9. Climate chamber for high temperatures and humidities: 1.5 m × 1.5 m, 10. Bandsaw for cutting samples: 2.0 m × 1.8 m.
Figure 2. Floor plan simple laboratory setup. 1. UV/VIS/NIR spectrometer: 2.7 m × 0.9 m, 2. Guarded hot plate for 90 × 90 sample: 2.5 m × 2.5 m, 3. Guarded hot plate for 30 × 30 sample: 1.0 m × 1.0 m, 4. Double climate chamber walk-in: 2.5 m × 2.8 m, 5. Scales with different capacity: 4.0 m × 0.6 m, 6. Water basin: 1.5 m × 2.5 m, 7. Heating cabinet for drying specimens: 1.5 m × 1.5 m, 8. Space for different apparatuses: 1.4 m × 0.6 m, 9. Climate chamber for high temperatures and humidities: 1.5 m × 1.5 m, 10. Bandsaw for cutting samples: 2.0 m × 1.8 m.
Sustainability 15 15921 g002
Figure 3. Floor plan for the extended laboratory setup. 1. UV/VIS/NIR spectrometer: 2.7 m × 0.9 m, 2. Guarded hot plate for 90 × 90 sample: 2.5 m × 2.5 m, 3. Guarded hot plate for 30 × 30 sample: 1.0 m × 1.0 m, 4. Double climate chamber walk-in: 2.5 m × 2.8 m, 5. Scales with different capacity: 4.0 m × 0.6 m, 6. Water basin: 1.5 m × 2.5 m, 7. Heating cabinet for drying specimens: 1.5 m × 1.5 m, 8. Climate chamber for high temperatures and humidity: 1.5 m × 1.5 m, 9. Bandsaw for cutting samples: 2.0 m × 1.8 m, 10. Hot box: 4.5 m × 5.0 m, 11. Air tightness test stand: 2.0 m × 5.0 m, 12. Solar simulator: 10 m2–80 m2.
Figure 3. Floor plan for the extended laboratory setup. 1. UV/VIS/NIR spectrometer: 2.7 m × 0.9 m, 2. Guarded hot plate for 90 × 90 sample: 2.5 m × 2.5 m, 3. Guarded hot plate for 30 × 30 sample: 1.0 m × 1.0 m, 4. Double climate chamber walk-in: 2.5 m × 2.8 m, 5. Scales with different capacity: 4.0 m × 0.6 m, 6. Water basin: 1.5 m × 2.5 m, 7. Heating cabinet for drying specimens: 1.5 m × 1.5 m, 8. Climate chamber for high temperatures and humidity: 1.5 m × 1.5 m, 9. Bandsaw for cutting samples: 2.0 m × 1.8 m, 10. Hot box: 4.5 m × 5.0 m, 11. Air tightness test stand: 2.0 m × 5.0 m, 12. Solar simulator: 10 m2–80 m2.
Sustainability 15 15921 g003
Table 1. WWR-related SHGC for glazing in Vietnam from the national technical regulations on energy efficiency in buildings (QCVN09:2017/BXD).
Table 1. WWR-related SHGC for glazing in Vietnam from the national technical regulations on energy efficiency in buildings (QCVN09:2017/BXD).
WWR (%)SHGC
NorthSouthOther Orientations
200.900.900.80
300.640.700.58
400.500.560.46
500.400.450.38
600.330.490.32
700.270.330.27
800.230.280.23
900.200.250.20
1000.170.220.17
NOTES: WWR calculated for each of the facades, then averaged for the entire building; If WWR did not match with the values in the table, SHGC values were determined through linear interpolation using the nearest higher and lower WWR values.
Table 2. Possible characteristic value determination with the simple laboratory setup.
Table 2. Possible characteristic value determination with the simple laboratory setup.
Physical PropertyUnitMeasurement SetupInvestment CostsTest StandardRef.
Thermal conductivity
Thermal resistance
[W/mK]
[m2K/W]
Guarded hot plate apparatus, climate chamber, oven, weighing equipment, and measuring instruments for size determinationEUR 20,000 to EUR 120,000ISO 8302, ASTM C518, EN 1946-3, EN 12664, EN 12667, EN 12939[34,35,36,37,38,39]
Heat capacity[J/kgK]Differential scanning calorimetryEUR 160,000ASTM E1269-11, ASTM E2716-09, EN ISO 11357-1, DIN 51007[40,41,42,43]
Bulk density[kg/m3]Ventilated oven (70 + 5) 9C, vacuum vessel (2.0 + 0.7) kPa, weighing device 0.1%, 0.1 mm, Le Chatelier flask 0 to 24 mL, sieve with a mesh size of 0.1 mmClimate Chamber 1, EUR 70,000;
Climate Chamber 2, EUR 70,000
EN 1097-6, EN 772-4[44,45]
Porosity[m3]EN 772-4, EN 1936[45,46]
Water vapor diffusion resistance[-]Climate chamber ± 5% ± 1.0 K, test vessel (glass metal), sealing compound (microcrystalline kerosene), measuring instruments with which the specimen thickness is determined, analytical balance error limit of 0.001 g, measuring probe, and a data acquisition system for temperature and relative humidityEN ISO 12572[47]
Moisture storage function[kg/m3]Weighing containers that do not absorb water, balance, with a margin of error of ±0.01% of the mass of the specimen, heating cabinet according to ISO 12570, desiccator, climatic chamberEN ISO 12571[48,49]
Water absorption coefficient (partial immersion)[kg/m2h0.5]Scale with which the mass of the specimen can be measured to ±0.1%, water tank with a device that keeps the water level constant to ±2 mm, stopwatchEN ISO 15148,[50]
Capillary water absorption[kg/m2min0.5]Stopwatch, weighing device, oven, climatic chamber, spatula, absorbent filter paper, metal moldEN 1015-18, DIN EN 772-11:[51,52]
Water absorption long-term immersion[kg/m2]Scale, water tank, stainless steel cageEN ISO 16535[53]
Radiation coefficients (τ, ρ, α)[%]UV/VIS/NIR spectrometerEUR 80,000DIN EN 410[29]
Light transmittance[%]DIN EN 410[29]
Irradiance[W/m2]PyranometerEUR 1500
Table 3. Additional characteristic value determination with the extended laboratory setup.
Table 3. Additional characteristic value determination with the extended laboratory setup.
Physical PropertyUnitMeasurement SetupInvestment CostsTest StandardRef.
U-value/R-value[W/m2K]Hot boxEUR 300,000–EUR 500,000DIN EN ISO 12567-1, DIN EN ISO 12567-2, DIN EN 12412-2, DIN EN 12412-4, DIN EN ISO 8990[54,55,56,57,58]
Air permeability of building components[m3/h]Test stand for holding the specimen, fan for generating a pressure difference, air-measuring section for determining the volume flow4 m × 4 m, EUR 150,000;
1 m × 1 m, EUR 10,000
EN 12114,[59]
Air permeability of curtain walls[m3/m2h]EN 12153[60]
Air tightness of windows, doors, and gates[m3/m2h], [m3/mh]EN 1026, EN 12207, EN 12427[61,62,63]
Total energy transmittance g-value[%]Test rig for determining total energy transmittance by the calorimetric methodEUR 200,000ISO 19467[64]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Le, T.S.; Zegowitz, A.; Le, C.C.; Künzel, H.; Schwede, D.; Luu, T.H.; Le, T.T.; Nguyen, T.T. The Development of Energy-Efficient and Sustainable Buildings: A Case Study in Vietnam. Sustainability 2023, 15, 15921. https://doi.org/10.3390/su152215921

AMA Style

Le TS, Zegowitz A, Le CC, Künzel H, Schwede D, Luu TH, Le TT, Nguyen TT. The Development of Energy-Efficient and Sustainable Buildings: A Case Study in Vietnam. Sustainability. 2023; 15(22):15921. https://doi.org/10.3390/su152215921

Chicago/Turabian Style

Le, Thi Song, Andreas Zegowitz, Cao Chien Le, Hartwig Künzel, Dirk Schwede, Thi Hong Luu, Trung Thanh Le, and Thi Tam Nguyen. 2023. "The Development of Energy-Efficient and Sustainable Buildings: A Case Study in Vietnam" Sustainability 15, no. 22: 15921. https://doi.org/10.3390/su152215921

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop