Next Article in Journal
Electrospun Nanofibers Revisited: An Update on the Emerging Applications in Nanomedicine
Next Article in Special Issue
Endosseous Dental Implant Materials and Clinical Outcomes of Different Alloys: A Systematic Review
Previous Article in Journal
Response Surface Methodology and Artificial Neural Network Modelling of Membrane Rotating Biological Contactors for Wastewater Treatment
Previous Article in Special Issue
Sealing Efficacy of the Original and Third-Party Custom-Made Abutments—Microbiological In Vitro Pilot Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Systematic Review

Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review

by
Raphaël Wakam
1,2,
Aurélie Benoit
1,
Kwamivi Bernardin Mawussi
3 and
Caroline Gorin
4,5,*
1
Unité de Recherche Biomatériaux Innovants et Interfaces, Université Paris Cité, 92120 Montrouge, France
2
Service d’Odontologie, Département de Prothèses, AP-HP/GH Paris Nord, 75018 Paris, France
3
Unité de Recherche Biomatériaux Innovants et Interfaces, Université Sorbonne Paris Nord, 92120 Montrouge, France
4
URP2496, Pathologie, Imagerie et Biothérapies Orofaciales, Université Paris Cité, 92120 Montrouge, France
5
Service d’Odontologie, Département de Prothèses, AP-HP/GH Pitié Salpétrière, 75013 Paris, France
*
Author to whom correspondence should be addressed.
Materials 2022, 15(5), 1933; https://doi.org/10.3390/ma15051933
Submission received: 2 January 2022 / Revised: 20 February 2022 / Accepted: 1 March 2022 / Published: 4 March 2022
(This article belongs to the Special Issue Dental Implants and Materials (Second Volume))

Abstract

Attachment systems (AS) enhance retention and stability by anchoring the overdentures to implants. Since 2002, the McGill consensus statement recommends the 2-implant-retained overdentures as the standard choice for edentulous mandible (2-IRMO). Considering the large number of AS available, it remains difficult for a practitioner to make a reasoned choice. A systematic review was conducted in PubMed/Medline and carried out independently by three authors, on retention, wear, and maintenance of AS used clinically or in vitro specifically for 1- or 2-IRMO. The 45 selected studies include 14 clinical and 31 in vitro studies. The risk of bias was evaluated according to the revised Cochrane risk of bias tool for randomized trials (RoB 2). The initial retention force of the cylindrical system is higher than the ball system. The retention loss, related to the wear of the retention device, is responsible for the most common need of maintenance, requiring activation or replacement. Plastic retention devices wear out faster and more significantly than metal ones, implying a worse time behavior of cylindrical systems, but their maintenance rate is similar. Neither system appears categorically superior. Cylindrical systems provide higher initial retention than ball ones; this advantage reduces over time with wear without affecting their need for maintenance.
Keywords: ball and cylindrical attachment systems; implant-retained overdenture; retention force; wear; maintenance ball and cylindrical attachment systems; implant-retained overdenture; retention force; wear; maintenance

Share and Cite

MDPI and ACS Style

Wakam, R.; Benoit, A.; Mawussi, K.B.; Gorin, C. Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review. Materials 2022, 15, 1933. https://doi.org/10.3390/ma15051933

AMA Style

Wakam R, Benoit A, Mawussi KB, Gorin C. Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review. Materials. 2022; 15(5):1933. https://doi.org/10.3390/ma15051933

Chicago/Turabian Style

Wakam, Raphaël, Aurélie Benoit, Kwamivi Bernardin Mawussi, and Caroline Gorin. 2022. "Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review" Materials 15, no. 5: 1933. https://doi.org/10.3390/ma15051933

APA Style

Wakam, R., Benoit, A., Mawussi, K. B., & Gorin, C. (2022). Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review. Materials, 15(5), 1933. https://doi.org/10.3390/ma15051933

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop