Next Article in Journal
A Novel Approach to Discrete Representative Volume Element Automation and Generation-DRAGen
Next Article in Special Issue
Relevant Design Aspects to Improve the Stability of Titanium Dental Implants
Previous Article in Journal
Functional Characteristics and Mechanical Performance of PCU Composites for Knee Meniscus Replacement
Previous Article in Special Issue
Errors in Implant Positioning Due to Lack of Planning: A Clinical Case Report of New Prosthetic Materials and Solutions
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional

by
Henrique Tuzzolo Neto
1,
Alessandra Sayuri Tuzita
1,*,
Sérgio Alexandre Gehrke
2,
Renata de Vasconcellos Moura
1,
Márcio Zaffalon Casati
1 and
Alfredo Mikail Melo Mesquita
1
1
Dental School, Universidade Paulista—UNIP, São Paulo 04026-002, Brazil
2
Biotechnology Department, Universidad Católica de Murcia, 11.100 Murci, Spain
*
Author to whom correspondence should be addressed.
Materials 2020, 13(8), 1888; https://doi.org/10.3390/ma13081888
Submission received: 28 December 2019 / Revised: 20 February 2020 / Accepted: 24 February 2020 / Published: 17 April 2020
(This article belongs to the Special Issue Dental Implants and Materials)

Abstract

This study aimed at performing a comparative analysis of the fracture resistance of implants, evaluating extra-narrow, narrow, and regular implants. Four groups containing 15 implants each were evaluated. Group 1 (G1): single-piece extra-narrow implants; Group 2 (G2): single-piece narrow implants; Group 3 (G3): Morse taper narrow implants with solid abutments; Group 4 (G4): Morse taper conventional implants with solid abutments. The implants were tested using a universal testing machine for their maximum force limit and their maximum bending moment. After obtaining the data, the Shapiro–Wilk, ANOVA, and Tukey (p < 0.05) statistical tests were applied. Samples from all the groups were analyzed by scanning electron microscopy and Groups 3 and 4 were analyzed by profilometry. The means and the standard deviation values for the maximum force limit (N) and the maximum bending moment (Nmm) were respectively: G1:134.29 N (10.27); G2:300.61 N (24.26); G3:360.64 N (23.34); G4:419.10 N (18.87); G1:1612.02 Nmm (100.6); G2:2945 Nmm (237.97); G3:3530.38 Nmm (228.75); G4:4096.7 Nmm (182.73). The groups behaved statistically different from each other, showing that the smallest diameter implants provided less fracture resistance, both in the tensile strength tests and in the maximum bending moment between all groups. Furthermore, single-piece implants, with 2.5 mm and 3.0 mm diameters, deformed in the implant body region area, rather than in the abutment region.
Keywords: narrow implants; extra-narrow implants; diameters of implants; dental implants narrow implants; extra-narrow implants; diameters of implants; dental implants

Share and Cite

MDPI and ACS Style

Tuzzolo Neto, H.; Tuzita, A.S.; Gehrke, S.A.; de Vasconcellos Moura, R.; Zaffalon Casati, M.; Mikail Melo Mesquita, A. A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional. Materials 2020, 13, 1888. https://doi.org/10.3390/ma13081888

AMA Style

Tuzzolo Neto H, Tuzita AS, Gehrke SA, de Vasconcellos Moura R, Zaffalon Casati M, Mikail Melo Mesquita A. A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional. Materials. 2020; 13(8):1888. https://doi.org/10.3390/ma13081888

Chicago/Turabian Style

Tuzzolo Neto, Henrique, Alessandra Sayuri Tuzita, Sérgio Alexandre Gehrke, Renata de Vasconcellos Moura, Márcio Zaffalon Casati, and Alfredo Mikail Melo Mesquita. 2020. "A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional" Materials 13, no. 8: 1888. https://doi.org/10.3390/ma13081888

APA Style

Tuzzolo Neto, H., Tuzita, A. S., Gehrke, S. A., de Vasconcellos Moura, R., Zaffalon Casati, M., & Mikail Melo Mesquita, A. (2020). A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional. Materials, 13(8), 1888. https://doi.org/10.3390/ma13081888

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop