Next Article in Journal
Precision Soil Moisture Monitoring Through Drone-Based Hyperspectral Imaging and PCA-Driven Machine Learning
Previous Article in Journal
Node Selection and Path Optimization for Passive Target Localization via UAVs
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electrode Setup for Electromyography-Based Silent Speech Interfaces: A Pilot Study

HiTZ Basque Center for Language Technology, University of the Basque Country, Ingeniero Torres Quevedo Plaza, 1, 48013 Bilbao, Spain
*
Authors to whom correspondence should be addressed.
Sensors 2025, 25(3), 781; https://doi.org/10.3390/s25030781
Submission received: 15 November 2024 / Revised: 15 January 2025 / Accepted: 25 January 2025 / Published: 28 January 2025
(This article belongs to the Section Biosensors)

Abstract

This paper describes a series of pilot experiments developed to define the electrode setup in order to record a novel parallel electromyography (EMG)–audio database. The main purpose of the database is to provide data useful for the development of an EMG-based silent speech interface for Spanish laryngectomized speakers. Motivated by the scarcity of information in related studies regarding this important decision-making process, we decided to carry out a set of experiments with multiple recording sessions and different setups. We included different electrode types (paired and concentric) and locations targeting different muscles in the face and neck involved in the speech production process. We then analyzed the results obtained in a phone classification task using frame-based phone accuracy. The final setup consists of eight channels with bipolar single-electrode pairs targeting eight specific muscles crucial for capturing speech-related information: the digastric, the depressor anguli oris, the risorius, the levator labii superioris, the masseter, the zygomaticus major, the depressor labii superioris, and the stylohyoid. This setup has been used for the final recordings in the database. By providing insight into the electrode setups that were used in related studies and the optimal setup that resulted from this pilot study, we hope that this research will help future researchers in the field in determining their experimental setup.
Keywords: electromyography; silent speech recognition; phone classification electromyography; silent speech recognition; phone classification

Share and Cite

MDPI and ACS Style

Salomons, I.; del Blanco, E.; Navas, E.; Hernáez, I. Electrode Setup for Electromyography-Based Silent Speech Interfaces: A Pilot Study. Sensors 2025, 25, 781. https://doi.org/10.3390/s25030781

AMA Style

Salomons I, del Blanco E, Navas E, Hernáez I. Electrode Setup for Electromyography-Based Silent Speech Interfaces: A Pilot Study. Sensors. 2025; 25(3):781. https://doi.org/10.3390/s25030781

Chicago/Turabian Style

Salomons, Inge, Eder del Blanco, Eva Navas, and Inma Hernáez. 2025. "Electrode Setup for Electromyography-Based Silent Speech Interfaces: A Pilot Study" Sensors 25, no. 3: 781. https://doi.org/10.3390/s25030781

APA Style

Salomons, I., del Blanco, E., Navas, E., & Hernáez, I. (2025). Electrode Setup for Electromyography-Based Silent Speech Interfaces: A Pilot Study. Sensors, 25(3), 781. https://doi.org/10.3390/s25030781

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop