Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (34)

Search Parameters:
Keywords = radiation attenuation equivalence

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 3001 KB  
Article
Investigation of Debris Mitigation in Droplet-Based Terbium Plasma Sources Produced by Laser Ablation Under Varying Buffer Gas Pressures
by Shuaichao Zhou, Tao Wu, Ziyue Wu, Junjie Tian and Peixiang Lu
Photonics 2025, 12(10), 1035; https://doi.org/10.3390/photonics12101035 - 19 Oct 2025
Viewed by 551
Abstract
The fragment suppression ability of terbium plasma generated by laser at different environmental pressures is investigated, with a focus on exploring the slowing effect of buffer gas on high-energy particles. Using two-dimensional radiation hydrodynamic simulations with the FLASH code, this study evaluates the [...] Read more.
The fragment suppression ability of terbium plasma generated by laser at different environmental pressures is investigated, with a focus on exploring the slowing effect of buffer gas on high-energy particles. Using two-dimensional radiation hydrodynamic simulations with the FLASH code, this study evaluates the debris mitigation efficiency of terbium plasma across a range of buffer gas pressures (50–1000 Pa). Key findings reveal that helium buffer gas exhibits a nonlinear pressure-dependent response in plasma dynamics and debris suppression. Specifically, at 1000 Pa helium, the plasma shockwave stops within stopping distance xst = 12.13 mm with an attenuation coefficient of b = 0.0013 ns−1, reducing radial expansion by 40% compared to 50 Pa (xst = 23.15 mm, b = 0.0010). This pressure scaling arises from enhanced collisional dissipation, confining over 80% of debris kinetic energy below 200 eV under 1000 Pa conditions. In contrast, argon exhibits superior stopping power within ion energy domains (≤1300 eV), attaining a maximum stopping power of 2000 eV·mm−1 at 1300 eV–a value associated with a 6.4-times-larger scattering cross-section compared to helium under equivalent conditions. The study uncovers a nonlinear relationship between kinetic energy and gas pressure, where the deceleration capability of buffer gases intensifies with increasing kinetic energy. This work demonstrates that by leveraging argon’s broadband stopping efficiency and helium’s confinement capacity, debris and high energy ions can be effectively suppressed, thereby securing mirror integrity and source efficiency at high repetition rates. Full article
(This article belongs to the Special Issue The Principle and Application of Photonic Metasurfaces)
Show Figures

Figure 1

18 pages, 4312 KB  
Article
Influence of Rare Earth Elements on the Radiation-Shielding Behavior of Serpentinite-Based Materials
by Ayşe Didem Kılıç and Demet Yılmaz
Appl. Sci. 2025, 15(14), 7837; https://doi.org/10.3390/app15147837 - 13 Jul 2025
Viewed by 1136
Abstract
In this study, the neutron and gamma radiation-shielding properties of serpentinites from the Guleman ophiolite complex were investigated, and results were evaluated in comparison with rare earth element (REE) content. The linear and mass attenuation coefficients (LAC and MAC), half-value layer (HVL), mean [...] Read more.
In this study, the neutron and gamma radiation-shielding properties of serpentinites from the Guleman ophiolite complex were investigated, and results were evaluated in comparison with rare earth element (REE) content. The linear and mass attenuation coefficients (LAC and MAC), half-value layer (HVL), mean free path (MFP), and effective atomic numbers (Zeff) of serpentinite samples were experimentally measured in the energy range of 80.99–383.85 keV. Theoretical MAC values were calculated. Additionally, fast neutron removal cross-sections, as well as thermal and fast neutron macroscopic cross-sections, were theoretically determined. The absorbed equivalent dose rates of serpentinite samples were also measured. The radiation protection efficiency (RPE) for gamma rays and neutrons were determined. It was observed that the presence of rare earth elements within serpentinite structure has a significant impact on thermal neutron cross-sections, while crystalline water content (LOI) plays an influential role in fast neutron cross-sections. Moreover, it has been observed that the concentration of gadolinium exerts a more substantial influence on the macroscopic cross-sections of thermal neutrons than on those of fast neutrons. The research results reveal the mineralogical, geochemical, morphological and radiation-shielding properties of serpentinite rocks contribute significantly to new visions for the use of this naturally occurring rock as a geological repository for nuclear waste or as a wall-covering material in radiotherapy centers and nuclear facilities instead of concrete. Full article
(This article belongs to the Special Issue Advanced Functional Materials and Their Applications)
Show Figures

Figure 1

25 pages, 5935 KB  
Article
Point-Kernel Code Development for Gamma-Ray Shielding Applications
by Mario Matijević, Krešimir Trontl, Siniša Šadek and Paulina Družijanić
Appl. Sci. 2025, 15(14), 7795; https://doi.org/10.3390/app15147795 - 11 Jul 2025
Viewed by 1288
Abstract
The point-kernel (PK) technique has a long history in applied radiation shielding, originating from the early days of digital computers. The PK technique applied to gamma-ray attenuation is one of many successful applications, based on the linear superposition principle applied to distributed radiation [...] Read more.
The point-kernel (PK) technique has a long history in applied radiation shielding, originating from the early days of digital computers. The PK technique applied to gamma-ray attenuation is one of many successful applications, based on the linear superposition principle applied to distributed radiation sources. Mathematically speaking, the distributed source will produce a detector response equivalent to the numerical integration of the radiation received from an equivalent number of point sources. In this treatment, there is no interference between individual point sources, while inherent limitations of the PK method are its inability to simulate gamma scattering in shields and the usage of simple boundary conditions. The PK method generally works for gamma-ray shielding with corrective B-factor for scattering and only specifically for fast neutron attenuation in a hydrogenous medium with the definition of cross section removal. This paper presents theoretical and programming aspects of the PK program developed for a distributed source of photons (line, disc, plane, sphere, slab volume, etc.) and slab shields. The derived flux solutions go beyond classical textbooks as they include the analytical integration of Taylor B-factor, obtaining a closed form readily suitable for programming. The specific computational modules are unified with a graphical user interface (GUI), assisting users with input/output data and visualization, developed for the fast radiological characterization of simple shielding problems. Numerical results of the selected PK test cases are presented and verified with the CADIS hybrid shielding methodology of the MAVRIC/SCALE6.1.3 code package from the ORNL. Full article
Show Figures

Figure 1

23 pages, 2728 KB  
Article
A Phantom-Based Study of the X-Ray Fluorescence Detectability of Iron, Copper, Zinc, and Selenium in the Human Blood of Superficial and Cutaneous Vasculature
by Mihai Raul Gherase and Vega Mahajan
Metrology 2025, 5(2), 23; https://doi.org/10.3390/metrology5020023 - 15 Apr 2025
Viewed by 2136
Abstract
Blood concentrations of essential trace elements can be used to diagnose conditions and diseases associated with excess or deficiency of these elements. Inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectroscopy (ICP-AES), and graphite furnace atomic absorption spectrometry (GF-AAS) have [...] Read more.
Blood concentrations of essential trace elements can be used to diagnose conditions and diseases associated with excess or deficiency of these elements. Inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectroscopy (ICP-AES), and graphite furnace atomic absorption spectrometry (GF-AAS) have been employed for such measurements, but maintenance and operation costs are high. X-ray fluorescence (XRF) detectability in cutaneous blood of iron (Fe), copper (Cu), zinc (Zn), and selenium (Se) was assessed as an alternative to ICP-MS. Three phantoms were made up of two polyoxymethylene (POM) plastic cylindrical cups of 0.6 mm and 1.0 mm thick walls and a 5.3 mm diameter POM cylindrical insert. Six aqueous solutions of Fe in 0 to 500 mg/L and Cu, Zn, and Se in 0 to 50 mg/L concentrations were poured into the phantoms to simulate X-ray attenuation of skin. Measurements using an integrated X-ray tube and polycapillary X-ray lens unit generated 24 calibration lines. Detection limit intervals in mg/L were (36–100), (14–40), (3.7–10), and (2.1–3.4) for Fe, Cu, Zn, and Se, respectively. Fe was the only element with detection limits lower than its 480 mg/L median human blood concentration. The estimated radiation dose and equivalent dose to skin were below those of common radiological procedures. Applications will require further instrumental development and finding a calibration method. Full article
Show Figures

Figure 1

27 pages, 10907 KB  
Article
Shielding Efficacy of Tungsten Oxide-Reinforced Polyisoprene in Attenuating Technetium-99m Gamma Radiation: An Alternative Shielding Solution for Occupational Safety in Nuclear Medicine
by Suphalak Khamruang Marshall, Jarasrawee Chuaymuang, Poochit Kwandee and Nueafa Songphum
Appl. Sci. 2025, 15(7), 3892; https://doi.org/10.3390/app15073892 - 2 Apr 2025
Cited by 4 | Viewed by 13404
Abstract
Tungsten oxide (WO3) is a high-density material with exceptional radiation attenuation properties, making it a strong candidate for advanced shielding applications. This study explores the structural, mechanical, and shielding performance of WO3-reinforced polyisoprene composites. Morphological analysis reveals a plate-like [...] Read more.
Tungsten oxide (WO3) is a high-density material with exceptional radiation attenuation properties, making it a strong candidate for advanced shielding applications. This study explores the structural, mechanical, and shielding performance of WO3-reinforced polyisoprene composites. Morphological analysis reveals a plate-like structure, indicating robust interfacial interactions that enhance mechanical integrity and thermal stability. X-ray diffraction confirms the crystalline nature of WO3, while Fourier transform infrared spectroscopy detects distinct W–O bond absorption bands, validating uniform dispersion. Computational analysis using XCOM demonstrates remarkable improvements in attenuation properties, particularly at intermediate- and high-photon energies. While PbO2 outperforms at lower energies due to the photoelectric effect, Phy-X/PSD analysis confirms that composites with ≥75% WO3 offer strong shielding capabilities. Variations in effective atomic number, linear attenuation coefficient, and mass attenuation coefficient establish WO3-reinforced NR as a compelling lead-free alternative, especially for Tc-99m applications. Experimental findings further reveal that increasing WO3 content significantly reduces Tc-99m gamma radiation dose equivalents Hp(0.07), Hp(3), and Hp(10), emphasizing the potential of WO3-reinforced composites for next-generation radiation shielding solutions. Full article
(This article belongs to the Section Materials Science and Engineering)
Show Figures

Figure 1

16 pages, 3892 KB  
Article
RETRACTED: The Multi-Station Fusion-Based Radiation Source Localization Method Based on Spectrum Energy
by Guojin He, Yulong Hao and Yaocong Xie
Sensors 2025, 25(5), 1339; https://doi.org/10.3390/s25051339 - 22 Feb 2025
Cited by 3 | Viewed by 1105 | Retraction
Abstract
Today’s highly complex and rapidly changing electromagnetic environment places higher demands on the precise localization of illegal radiation sources. In response to this, this paper innovatively proposes a multi-station fusion-based radiation source localization method, which leverages the frequency, field strength, bandwidth, and other [...] Read more.
Today’s highly complex and rapidly changing electromagnetic environment places higher demands on the precise localization of illegal radiation sources. In response to this, this paper innovatively proposes a multi-station fusion-based radiation source localization method, which leverages the frequency, field strength, bandwidth, and other characteristic information embedded in frequency band scanning data. The method thoroughly explores the energy characteristics of the detected radiation sources while closely integrating the objective laws of propagation attenuation in electromagnetic space. By employing an advanced, normalized power calculation technique, it successfully achieves high-precision localization of the radiation source. Through rigorous and thorough experimental validation, this method reduces localization errors by 25% and cuts the equivalent radiation power error by 30% compared to traditional localization methods. This achievement provides more reliable and accurate technical support for applications in the electromagnetic field, offering promising prospects for advancing and refining electromagnetic environment monitoring and management technologies. Full article
(This article belongs to the Section Navigation and Positioning)
Show Figures

Figure 1

16 pages, 1787 KB  
Article
A Method for Calculating Small Sizes of Volumes in Postsurgical Thyroid SPECT/CT Imaging
by Elena Ttofi, Costas Kyriacou, Theodoros Leontiou and Yiannis Parpottas
Life 2025, 15(2), 200; https://doi.org/10.3390/life15020200 - 29 Jan 2025
Viewed by 1603
Abstract
Differentiated thyroid cancer treatment typically involves the surgical removal of the whole or largest part of the thyroid gland. Diagnostic procedures are useful both before and after treatment to determine the need for radioiodine ablation, re-stage the disease, monitor disease progression, or evaluate [...] Read more.
Differentiated thyroid cancer treatment typically involves the surgical removal of the whole or largest part of the thyroid gland. Diagnostic procedures are useful both before and after treatment to determine the need for radioiodine ablation, re-stage the disease, monitor disease progression, or evaluate treatment efficacy. SPECT/CT imaging can be utilized to identify small, distant iodine-avid metastatic lesions and assess their uptake and volume for the above purposes as well as for performing lesion-based dosimetry when indicated. The objective of this study was to develop and validate a method for calculating small sizes of volumes in SPECT/CT imaging as well as to perform calculations utilizing I-131 and I-123 postsurgical SPECT/CT images from a neck–thyroid phantom. In this approach, the calculated volume was unaffected by radiation spillover from high-uptake voxels since it was the result from the successive application of the gray-level histogram technique to SPECT and CT 3D matrices. Beforehand, the SPECT 3D matrix was resized and aligned to the corresponding CT one. The method was validated following the clinical protocols for postsurgical thyroid imaging by using I-123 and I-131 scatter and attenuation-corrected SPECT/CT images from a neck–thyroid phantom. The phantom could accommodate two volumes of different sizes (0.5, 1, 1.5, 3, and 10 mL) and enclose anatomical tissue-equivalent main scattering structures. For the 0.5 and 10 mL volumes, the % differences between the actual and the calculated volumes were 15.2% and 1.2%, respectively. Radiation spillover was only present in SPECT images, and it was more profound at higher administered activities, in I-131 than in I-123 images, and in smaller volumes. When SPECT/low-dose-CT imaging is performed, this method is capable of accurately calculating small volumes without the need of additional modalities. Full article
(This article belongs to the Special Issue Current Progress in Medical Image Segmentation)
Show Figures

Figure 1

24 pages, 9132 KB  
Article
Development of a 3D-Printed Chest Phantom with Simulation of Lung Nodules for Studying Ultra-Low-Dose Computed Tomography Protocols
by Jenna Silberstein, Steven Tran, Yin How Wong, Chai Hong Yeong and Zhonghua Sun
Appl. Sci. 2025, 15(1), 309; https://doi.org/10.3390/app15010309 - 31 Dec 2024
Cited by 4 | Viewed by 3831
Abstract
This study aimed to 3D print a patient-specific chest phantom simulating multiple lung nodules to optimise low-dose Computed Tomography (CT) protocols for lung cancer screening. The chest phantom, which was developed from a single patient’s chest CT images, was fabricated using a variety [...] Read more.
This study aimed to 3D print a patient-specific chest phantom simulating multiple lung nodules to optimise low-dose Computed Tomography (CT) protocols for lung cancer screening. The chest phantom, which was developed from a single patient’s chest CT images, was fabricated using a variety of materials, including polylactic acid (PLA), Glow-PLA, acrylonitrile butadiene styrene (ABS), and polyurethane resin. The phantom was scanned under different low-dose (LDCT) and ultra-low-dose CT (ULDCT) protocols by varying the kilovoltage peak (kVp) and milliampere-seconds (mAs). Subjective image quality of each scan (656 images) was evaluated by three radiologists using a five-point Likert scale, while objective image quality was assessed using signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Anatomical conformance was assessed by comparing tissue diameters of the phantom and patient scans using Bland–Altman analysis. The phantom’s lung tissue, lung nodules, and diaphragm demonstrated radiation attenuation comparable to patient tissue, as measured in Hounsfield Units (HU). However, significant variations in HU were observed for the skin, subcutaneous fat, muscle, bone, heart, lung vessels, and blood vessels compared to patient tissues, with values ranging from 93.9 HU to −196 HU (p < 0.05). Both SNR and CNR decreased as the effective dose was reduced, with a strong positive linear correlation (r = 0.927 and r = 0.931, respectively, p < 0.001, Jamovi, version 2.3.28). The median subjective image quality score from radiologists was 4, indicating good diagnostic confidence across all CT protocols (κ = −0.398, 95% CI [−0.644 to −0.152], p < 0.002, SPSS Statistics, version 30). An optimal protocol of 80 kVp and 30 mAs was identified for lung nodule detection, delivering a dose of only 0.23 mSv, which represents a 96% reduction compared to standard CT protocols. The measurement error between patient and phantom scans was −0.03 ± 0.14 cm. These findings highlight the potential for significant dose reductions in lung cancer screening programs. Further studies are recommended to improve the phantom by selecting more tissue-equivalent materials. Full article
Show Figures

Figure 1

11 pages, 1142 KB  
Article
An Age-Based Size-Specific Dose Estimate for Pediatric Computed Tomography Head Examinations Performed at Songklanagarind Hospital, Thailand, from 2017 to 2019
by Saowapark Poosiri, Kanokkwan Chuboonlap and Nuttita Kaewlaied
Appl. Sci. 2024, 14(17), 7848; https://doi.org/10.3390/app14177848 - 4 Sep 2024
Cited by 2 | Viewed by 2817
Abstract
Computed tomography (CT) is the primary source of diagnostic radiation in pediatric patients. Patient head size and tissue attenuation are critical factors for estimating CT radiation doses. This study aimed to determine a size-specific dose estimate based on the water-equivalent diameter (SSDEDw [...] Read more.
Computed tomography (CT) is the primary source of diagnostic radiation in pediatric patients. Patient head size and tissue attenuation are critical factors for estimating CT radiation doses. This study aimed to determine a size-specific dose estimate based on the water-equivalent diameter (SSDEDw) for pediatric CT head examinations, categorized by age group, and to investigate the parameters influencing the SSDEDw. This retrospective analysis included 274 pediatric patients aged 0 to 15 years who underwent non-contrast CT head examinations using an age-based protocol without automatic exposure control systems. The SSDEDw was calculated using the CTDIvol, and the conversion factor was derived from AAPM Report No. 293, based on the water-equivalent diameter (Dw). We found that the SSDEDw of age groups of 0 to 6 months, 6 months to 3 years, 3 to 6 years, 6 to 12 years, and 12 to 15 years were 15.4 (14.8, 15.8), 20.1 (19.6, 20.6), 25.3 (24.6, 25.7), 28.1 (27.3, 28.8), and 35.1 (34.6, 36) mGy, respectively. Age and body weight significantly affected the SSDEDw, with high R-squared values of 0.87 and 0.63, respectively (p < 0.001). The SSDE, particularly when based on the water-equivalent diameter (SSDEDW), is a valuable supplement to the DLP and the CTDIvol as it closely relates to patient dose, especially for pediatric head scans of different patient sizes. Full article
(This article belongs to the Special Issue Advances in Diagnostic Radiology)
Show Figures

Figure 1

15 pages, 4708 KB  
Article
Minitype Arrays of Acoustically Actuated Magnetoelectric Antennas for Magnetic Induction Communication
by Shiyu Wang, Gaoqi Dou and Guangming Song
Actuators 2024, 13(8), 276; https://doi.org/10.3390/act13080276 - 23 Jul 2024
Cited by 3 | Viewed by 1615
Abstract
The magnetoelectric (ME) antennas rely on the mechanical movement of magnetic dipoles, making it possible to break the constraints on physical dimensions decided by the wavelength of the electromagnetic wavelength. The ME antennas achieve super-low frequency (SLF) communications with a smaller size to [...] Read more.
The magnetoelectric (ME) antennas rely on the mechanical movement of magnetic dipoles, making it possible to break the constraints on physical dimensions decided by the wavelength of the electromagnetic wavelength. The ME antennas achieve super-low frequency (SLF) communications with a smaller size to provide a novel solution for long-range, underwater, and underground communications; navigation over the horizon; and geological exploring. As a result, further theoretical research and optimization of ME antennas have been an open challenge for decades. Here, we report on minitype arrays of acoustically actuated ME antenna and their more rigorous equivalent circuits. These arrays of ME antenna adjust amplitude-frequency response through the mechanical regulation method. The mechanical parameters of ME antennas in the arrays result in regulating amplitude-frequency response, such as working frequency, fractional bandwidth, and intensity of magnetic induction. Our work provides a more accurate theoretical model and diverse array form over state-of-the-art ME antenna arrays. The frequency, fractional bandwidth, and magnetic induction strength of the ME antenna arrays were achieved to be adjustable in the ranges of 84 to 181 Hz, 3.9% to 8.3%, and two to four times, respectively. In addition, we have calculated the attenuation characteristics of ME antennas and their minitype arrays in seawater. The results show that the ME antenna array described in this manuscript is able to enhance the radiation intensity and information-loading capability, which has a positive potential for application in SLF communication systems. Full article
Show Figures

Figure 1

29 pages, 1959 KB  
Systematic Review
Advances and Applications of Three-Dimensional-Printed Patient-Specific Chest Phantoms in Radiology: A Systematic Review
by Jenna Silberstein and Zhonghua Sun
Appl. Sci. 2024, 14(13), 5467; https://doi.org/10.3390/app14135467 - 24 Jun 2024
Cited by 5 | Viewed by 3620
Abstract
Lung cancer screening would benefit from low-dose CT protocols optimized by means of a highly accurate three-dimensional radiation-equivalent thoracic phantom. However, whether three-dimensional (3D)-printed chest phantoms have been used for this purpose is unclear, as is their current scope of application. This systematic [...] Read more.
Lung cancer screening would benefit from low-dose CT protocols optimized by means of a highly accurate three-dimensional radiation-equivalent thoracic phantom. However, whether three-dimensional (3D)-printed chest phantoms have been used for this purpose is unclear, as is their current scope of application. This systematic review aims to explore the range of applications of 3D-printed thoracic phantoms, along with the techniques, materials, and anatomical structures they replicate. Relevant articles were identified using a systematic search strategy across PubMed and Scopus databases, based on pre-determined selection criteria. In total, 20 articles were eligible and critically analysed, all consisting of phantom experiments. Findings reveal that a diverse range of thoracic organs have been 3D-printed, predominantly via fused-deposition modelling incorporating polylactic acid, however, often representing discreet or limited structures. A comprehensive radiation-equivalent chest phantom that mimics the full gamut of thoracic structures is warranted. Most studies are still in their preliminary testing stages, primarily assessing the feasibility of creating morphologically accurate thoracic structures with radiation equivalence. Few studies have progressed to explore their applications. Notably, most investigations into applications have concentrated on dose reduction and CT protocol optimisation for cardiac purposes, rather than pulmonary applications, despite the inclusion of lung cancer nodules in some phantoms. Full article
(This article belongs to the Section Additive Manufacturing Technologies)
Show Figures

Figure 1

23 pages, 5723 KB  
Article
Applicability of an Ionising Radiation Measuring System for Real-Time Effective-Dose-Optimised Route Finding Solution during Nuclear Accidents
by Attila Zsitnyányi, János Petrányi, Jácint Jónás, Zoltán Garai, Lajos Kátai-Urbán, Iván Zádori and István Kobolka
Fire 2024, 7(4), 142; https://doi.org/10.3390/fire7040142 - 16 Apr 2024
Cited by 3 | Viewed by 1933
Abstract
The reduction in the effective dose of evacuated injured persons through contaminated areas of nuclear accidents is an essential emergency services requirement. In this context, there appeared a need to develop a dose-optimised route finding method for firefighting rescue vehicles, which includes the [...] Read more.
The reduction in the effective dose of evacuated injured persons through contaminated areas of nuclear accidents is an essential emergency services requirement. In this context, there appeared a need to develop a dose-optimised route finding method for firefighting rescue vehicles, which includes the development of a real-time decision support measurement and evaluation system. This determines and visualises the radiation exposure of possible routes in a tested area. The system inside and outside of the vehicle measures the ambient dose equivalent rate, the gamma spectra, and also the airborne radioactive aerosol and iodine levels. The method uses gamma radiation measuring NaI(Tl) scintillation detectors mounted on the outside of the vehicle, to determine the dose rate inside the vehicle using the previously recorded attenuation conversation function, while continuously collecting the air through a filter and using an alpha, beta, and gamma radiation measuring NaI(Tl)+ PVT + ZnS(Ag) scintillator to determine the activity concentration in the air, using these measured values to determine the effective dose for all routes and all kinds of vehicles. The energy-dependent shielding effect of the vehicle, the filtering efficiency of the collective protection equipment, and the vehicle’s speed and travel time were taken into account. The results were validated by using gamma point sources with different activity and energy levels. The measurement results under real conditions and available real accident data used in our simulations for three different vehicles and pedestrians proved the applicability of the system. During a nuclear accident based on our model calculations, the inhalation of radioactive aerosols causes a dose almost an order of magnitude higher than the external gamma radiation caused by the fallout contamination. The selection of the appropriate vehicle and its route is determined by the spectrum that can be measured at the accident site but especially by the radioactive aerosol concentration in the air that can be measured in the area. In the case of radiation measuring detectors, the shielding effect of the carrier vehicle must be taken into account, especially in the case of heavy shielding vehicles. The method provides an excellent opportunity to reduce the damage to the health of accident victims and first responders during rescue operations. Full article
Show Figures

Figure 1

11 pages, 4601 KB  
Article
Comparison of Virtual Non-Contrast and True Non-Contrast CT Images Obtained by Dual-Layer Spectral CT in COPD Patients
by Manuel Steinhardt, Alexander W. Marka, Sebastian Ziegelmayer, Marcus Makowski, Rickmer Braren, Markus Graf and Joshua Gawlitza
Bioengineering 2024, 11(4), 301; https://doi.org/10.3390/bioengineering11040301 - 22 Mar 2024
Cited by 5 | Viewed by 4853
Abstract
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of [...] Read more.
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of the 300 million CT scans per year are contrast-enhanced, no proper emphysema quantification is available in a one-stop-shop approach for patients with known or newly diagnosed COPD. Since the introduction of spectral imaging (e.g., dual-energy CT scanners), it has been possible to create virtual non-contrast-enhanced images (VNC) from contrast-enhanced images, making it theoretically possible to offer proper COPD imaging despite contrast enhancing. This study is aimed towards investigating whether these VNC images are comparable to true non-contrast-enhanced images (TNC), thereby reducing the radiation exposure of patients and usage of resources in hospitals. In total, 100 COPD patients with two scans, one with (VNC) and one without contrast media (TNC), within 8 weeks or less obtained by a spectral CT using dual-layer technology, were included in this retrospective study. TNC and VNC were compared according to their voxel-density histograms. While the comparison showed significant differences in the low attenuated volumes (LAVs) of TNC and VNC regarding the emphysema threshold of −950 Houndsfield Units (HU), the 15th and 10th percentiles of the LAVs used as a proxy for pre-emphysema were comparable. Upon further investigation, the threshold-based LAVs (−950 HU) of TNC and VNC were comparable in patients with a water equivalent diameter (DW) below 270 mm. The study concludes that VNC imaging may be a viable option for assessing emphysema progression in COPD patients, particularly those with a normal body mass index (BMI). Further, pre-emphysema was generally comparable between TNC and VNC. This approach could potentially reduce radiation exposure and hospital resources by making additional TNC scans obsolete. Full article
(This article belongs to the Special Issue Computed Tomography Techniques and Applications)
Show Figures

Figure 1

15 pages, 5941 KB  
Article
Effect of Waste Iron Filings (IF) on Radiation Shielding Feature of Polyepoxide Composites
by Mohammed T. Alresheedi and Mohamed Elsafi
Crystals 2023, 13(8), 1168; https://doi.org/10.3390/cryst13081168 - 27 Jul 2023
Cited by 7 | Viewed by 1806
Abstract
In the present work, photon and neutron attenuation properties of polyepoxide composites produced by doping waste iron filings (IF) at different percentages (0%, 20%, 40%, and 60% iron filing percentage) were obtained using theoretical and experimental techniques. The experimental technique was performed using [...] Read more.
In the present work, photon and neutron attenuation properties of polyepoxide composites produced by doping waste iron filings (IF) at different percentages (0%, 20%, 40%, and 60% iron filing percentage) were obtained using theoretical and experimental techniques. The experimental technique was performed using an HPGe detector with four different gamma lines (0.0595, 0.6617, 1.173, and 1.333 MeV) emitted from three gamma-ray sources (241Am, 137Cs, and 60Co). The theoretical techniques for shielding parameters calculation are estimated with Phy-X software and the XCOM program as well. The experimental and theoretical values of the mass/linear attenuation coefficient (M/LAC), half/tenth value layer (H/TVL), mean free path (MFP), lead equivalent thickness (LEth), and radiation shielding efficiency (RSE) have been determined and compared. A good agreement was achieved during the comparison. The shielding performance of the prepared composites increased with increasing the iron filing rate, where we can arrange the performance of shielding according to EP–IF60 > EP–IF40 > EP–IF20 > EP–IF0 at all different experimental and theoretical energies. The effective and equivalent (Zeff, Zeq) atomic numbers as well as the exposure buildup factor (EBF) at different depletion distances or mean free paths (MFPs) have been calculated for all EP–IF composites. The lowest EBF was for EP–IF60 while the highest EBF was for EP–IF0 through the discussed energy from 0.015 to 15 MeV. Finally, the fast neutron removal cross-section (FRNC) has been calculated for the prepared composites and the results showed improvement in FNRC with increasing the iron filing rate. Full article
(This article belongs to the Topic Recent Advances in Ionizing Radiation Shielding Materials)
(This article belongs to the Section Hybrid and Composite Crystalline Materials)
Show Figures

Figure 1

12 pages, 5082 KB  
Article
Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
by Giuseppe M. Bucolo, Velio Ascenti, Simone Barbera, Federico Fontana, Francesco M. Aricò, Filippo Piacentino, Andrea Coppola, Giuseppe Cicero, Maria Adele Marino, Christian Booz, Thomas J. Vogl, Tommaso D’Angelo, Massimo Venturini and Giorgio Ascenti
J. Clin. Med. 2023, 12(14), 4718; https://doi.org/10.3390/jcm12144718 - 17 Jul 2023
Cited by 12 | Viewed by 2614
Abstract
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with [...] Read more.
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses. Full article
Show Figures

Figure 1

Back to TopTop