Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (128)

Search Parameters:
Keywords = plastic optical fiber sensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2709 KiB  
Article
An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection
by Nunzio Cennamo, Francesco Arcadio, Chiara Marzano, Rosalba Pitruzzella, Mimimorena Seggio, Maria Pesavento, Stefano Toldo, Antonio Abbate and Luigi Zeni
Sensors 2025, 25(3), 930; https://doi.org/10.3390/s25030930 - 4 Feb 2025
Viewed by 1067
Abstract
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where [...] Read more.
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where the bioreceptor’s (protein antibody) molecular weight is roughly ten times that of the analyte (protein interleukin), while intracellular bioreceptors and small molecules at low molecular weight interactions have already been demonstrated via the same point-of-care test (POCT). The POCT was implemented by a white light source and a spectrometer connected via two POF-based chips connected in series: an innovative microcuvette chip and a D-shaped POF surface plasmon resonance (SPR) probe. In particular, the POF microcuvette chip was achieved by drilling three micro holes in the core of a modified POF. Instead of performing a functionalization step, the micro holes were filled with a specific receptor solution for the analyte (one microliter at the femtomolar level), which selectively captured the target (e.g., cytokine) when the samples were dropped over the filled micro holes (twenty microliters at the attomolar level). Three interleukins, IL-1β, IL-17A, and IL-18, were detected in the attomolar concentrations range by monitoring the resonance wavelength shift over time due to the cytokine/antibody (protein–protein) interaction. The POF-based device was proven to be effective for detecting several interleukins at the attomolar level in a few minutes and without functionalization processes. Full article
(This article belongs to the Special Issue Advanced Optics and Photonics Technologies for Sensing Applications)
Show Figures

Figure 1

13 pages, 3213 KiB  
Article
Tailored Compositions of Ni-Ti-Sn Nanopowders Deposited on Polymer Fiber Optics Through Flash Evaporation
by Elango Natarajan, Anil Chouhan, Santheraleka Ramanathan, Kalaimani Markandan, Santhosh Mozhuguan Sekar, Chun Kit Ang, Nagarajan Deivanayagampillai and Gérald Franz
J. Compos. Sci. 2024, 8(12), 526; https://doi.org/10.3390/jcs8120526 - 13 Dec 2024
Cited by 1 | Viewed by 878
Abstract
Fiber coatings protect the glass surface of fiber from extrinsic environmental factors. The coating of shape memory alloy over fiber is useful in sensor fabrication where the state of deformation is affected by the phase transformation of the coated material. In addition, coated [...] Read more.
Fiber coatings protect the glass surface of fiber from extrinsic environmental factors. The coating of shape memory alloy over fiber is useful in sensor fabrication where the state of deformation is affected by the phase transformation of the coated material. In addition, coated plastic fibers can be used in elevated temperature environments. To this end, the present research aims to investigate the effect of the Ni-Ti-Sn composite coating over the fiber. Homogeneous particle distribution, agglomeration, porosity and the ability to obtain uniform coating thickness have been general concerns in fiber coatings. Hence, the present study comprehensively investigated the mechanical and thermal behavior as well as morphological properties of Ni-Ti-Sn nanopowders deposited on polymer fiber optics. Five sets of polyamide-coated samples with different Ni-Ti-Sn proportions were fabricated and characterized. Morphological studies confirmed that an even coating thickness enhanced the mechanical integrity and optical performance. The optimum composition demonstrated superior tensile strength of 29.5 MPa and a 25% increase in elongation compared to the uncoated sample. The Ni-Ti-Sn alloy composition investigated in the present study is promising for industrial applications where thermal stability and mechanical performance are warranted. Full article
(This article belongs to the Special Issue Polymer Composites and Fibers, 3rd Edition)
Show Figures

Figure 1

18 pages, 3739 KiB  
Article
An MIP-Based PFAS Sensor Exploiting Nanolayers on Plastic Optical Fibers for Ultra-Wide and Ultra-Low Detection Ranges—A Case Study of PFAS Detection in River Water
by Rosalba Pitruzzella, Alessandro Chiodi, Riccardo Rovida, Francesco Arcadio, Giovanni Porto, Simone Moretti, Gianfranco Brambilla, Luigi Zeni and Nunzio Cennamo
Nanomaterials 2024, 14(21), 1764; https://doi.org/10.3390/nano14211764 - 3 Nov 2024
Cited by 3 | Viewed by 3065
Abstract
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance [...] Read more.
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance (SPR) phenomena. The sensor is realized by the coupling of an SPR-POF platform with a novel chemical chip based on different polymeric nanolayers over the core of a D-shaped POF, one made up of an optical adhesive and one of a molecularly imprinted polymer (MIP) for PFAS. The chemical chip is used to launch the light into the SPR D-shaped POF platform, so the interaction between the analyte and the MIP’s sites can be used to modulate the propagated light in the POFs and the SPR phenomena. Selectivity tests and dose–response curves by standard PFOA water solutions were carried out to characterize the detection range sensor response, obtaining a wide PFAS response range, from 1 ppt to 1000 ppt. Then, tests performed on river water samples collected from the Bormida river paved the way for the applicability of the proposed approach to a real scenario. Full article
Show Figures

Figure 1

18 pages, 3070 KiB  
Article
An Optical Device Based on a Chemical Chip and Surface Plasmon Platform for 2-Furaldehyde Detection in Insulating Oil
by Letizia De Maria, Francesco Arcadio, Giuseppe Gabetta, Daniele Merli, Giancarla Alberti, Luigi Zeni, Nunzio Cennamo and Maria Pesavento
Sensors 2024, 24(16), 5261; https://doi.org/10.3390/s24165261 - 14 Aug 2024
Cited by 1 | Viewed by 1304
Abstract
2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil–paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; [...] Read more.
2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil–paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; sensing devices for 2-FAL analysis in a wide concentration range are of high interest in these systems. An optical sensor system is proposed; this consists of a chemical chip, able to capture 2-FAL from the insulating oil, coupled with a surface plasmon resonance (SPR) probe, both realized on multimode plastic optical fibers (POFs). The SPR platform exploits gold nanofilm or, alternatively, a double layer of gold and silicon oxide to modulate the sensor sensitivity. The capturing chip is always based on the same molecularly imprinted polymer (MIP) as a receptor specific for 2-FAL. The system with the SPR probe based on a gold nanolayer had a higher sensitivity and a lower detection limit of fractions of μg L−1. Instead, the SPR probe, based on a double layer (gold and silicon oxide), has a lower sensitivity with a worse detection limit, and it is suitable for the detection of 2-FAL at concentrations of 0.01–1 mg L−1. Full article
Show Figures

Figure 1

12 pages, 2991 KiB  
Article
An Efficient Bio-Receptor Layer Combined with a Plasmonic Plastic Optical Fiber Probe for Cortisol Detection in Saliva
by Francesco Arcadio, Mimimorena Seggio, Rosalba Pitruzzella, Luigi Zeni, Alessandra Maria Bossi and Nunzio Cennamo
Biosensors 2024, 14(7), 351; https://doi.org/10.3390/bios14070351 - 19 Jul 2024
Cited by 4 | Viewed by 2029
Abstract
Cortisol is a clinically validated stress biomarker that takes part in many physiological and psychological functions related to the body’s response to stress factors. In particular, it has emerged as a pivotal tool for understanding stress levels and overall well-being. Usually, in clinics, [...] Read more.
Cortisol is a clinically validated stress biomarker that takes part in many physiological and psychological functions related to the body’s response to stress factors. In particular, it has emerged as a pivotal tool for understanding stress levels and overall well-being. Usually, in clinics, cortisol levels are monitored in blood or urine, but significant changes are also registered in sweat and saliva. In this work, a surface plasmon resonance probe based on a D-shaped plastic optical fiber was functionalized with a glucocorticoid receptor exploited as a highly efficient bioreceptor specific to cortisol. The developed plastic optical fiber biosensor was tested for cortisol detection in buffer and artificial saliva. The biosensor response showed very good selectivity towards other hormones and a detection limit of about 59 fM and 96 fM in phosphate saline buffer and artificial saliva, respectively. The obtained detection limit, with a rapid detection time (about 5 min) and a low-cost sensor system, paved the way for determining the cortisol concentration in saliva samples without any extraction process or sample pretreatment via a point-of-care test. Full article
(This article belongs to the Special Issue Plasmonic Biosensors for Biomedical Applications)
Show Figures

Figure 1

13 pages, 3119 KiB  
Article
Plasmonic Optical Fiber Sensors and Molecularly Imprinted Polymers for Glyphosate Detection at an Ultra-Wide Range
by Luca Pasquale Renzullo, Ines Tavoletta, Giancarla Alberti, Luigi Zeni, Maria Pesavento and Nunzio Cennamo
Chemosensors 2024, 12(7), 142; https://doi.org/10.3390/chemosensors12070142 - 17 Jul 2024
Cited by 3 | Viewed by 1825
Abstract
In this study, a surface plasmon resonance (SPR) sensor based on modified plastic optical fibers (POFs) was combined with a specific molecularly imprinted polymer (MIP), used as a synthetic receptor, for glyphosate (GLY) determination in aqueous solutions. Since GLY is a non-selective herbicide [...] Read more.
In this study, a surface plasmon resonance (SPR) sensor based on modified plastic optical fibers (POFs) was combined with a specific molecularly imprinted polymer (MIP), used as a synthetic receptor, for glyphosate (GLY) determination in aqueous solutions. Since GLY is a non-selective herbicide associated with severe environmental and health problems, detecting glyphosate in environmental and biological samples remains challenging. The selective interaction between the MIP layer and GLY is monitored by exploiting the SPR phenomenon at the POF’s gold surface. Experimental results show that in about ten minutes and by dropping microliter volume samples, the presented optical–chemical sensor can quantify up to three orders of magnitude of GLY concentrations, from nanomolar to micromolar, due to a thin MIP layer over the SPR surface. The developed optical–chemical sensor presents a detection limit of about 1 nM and can be used for onsite GLY measurements. Moreover, the experimental analysis demonstrated the high selectivity of the proposed POF-based chemical sensor. Full article
Show Figures

Figure 1

20 pages, 36354 KiB  
Article
Optoelectronic Strain-Measurement System Demonstrated on Scaled-Down Flywheels
by Matthias Franz Rath, Christof Birgel, Armin Buchroithner, Bernhard Schweighofer and Hannes Wegleiter
Sensors 2024, 24(13), 4292; https://doi.org/10.3390/s24134292 - 1 Jul 2024
Viewed by 1588
Abstract
Monitoring the strain in the rotating flywheel in a kinetic energy storage system is important for safe operation and for the investigation of long-term effects in composite materials like carbon-fiber-reinforced plastics. An optoelectronic strain-measurement system for contactless deformation and position monitoring of a [...] Read more.
Monitoring the strain in the rotating flywheel in a kinetic energy storage system is important for safe operation and for the investigation of long-term effects in composite materials like carbon-fiber-reinforced plastics. An optoelectronic strain-measurement system for contactless deformation and position monitoring of a flywheel was investigated. The system consists of multiple optical sensors measuring the local relative in-plane displacement of the flywheel rotor. A special reflective pattern, which is necessary to interact with the sensors, was applied to the surface of the rotor. Combining the measurements from multiple sensors makes it possible to distinguish between the deformation and in-plane displacement of the flywheel. The sensor system was evaluated using a low-speed steel rotor for single-sensor performance investigation as well as a scaled-down high-speed rotor made from PVC plastic. The PVC rotor exhibits more deformation due to centrifugal stresses than a steel or aluminum rotor of the same dimensions, which allows experimental measurements at a smaller flywheel scale as well as a lower rotation speed. Deformation measurements were compared to expected deformation from calculations. The influence of sensor distance was investigated. Deformation and position measurements as well as derived imbalance measurements were demonstrated. Full article
(This article belongs to the Special Issue Advances in Optical Sensing, Instrumentation and Systems: 2nd Edition)
Show Figures

Figure 1

12 pages, 2129 KiB  
Communication
Splitter-Based Sensors Realized via POFs Coupled by a Micro-Trench Filled with a Molecularly Imprinted Polymer
by Ines Tavoletta, Francesco Arcadio, Luca Pasquale Renzullo, Giuseppe Oliva, Domenico Del Prete, Debora Verolla, Chiara Marzano, Giancarla Alberti, Maria Pesavento, Luigi Zeni and Nunzio Cennamo
Sensors 2024, 24(12), 3928; https://doi.org/10.3390/s24123928 - 17 Jun 2024
Cited by 6 | Viewed by 1381
Abstract
An optical–chemical sensor based on two modified plastic optical fibers (POFs) and a molecularly imprinted polymer (MIP) is realized and tested for the detection of 2-furaldehyde (2-FAL). The 2-FAL measurement is a scientific topic of great interest in different application fields, such as [...] Read more.
An optical–chemical sensor based on two modified plastic optical fibers (POFs) and a molecularly imprinted polymer (MIP) is realized and tested for the detection of 2-furaldehyde (2-FAL). The 2-FAL measurement is a scientific topic of great interest in different application fields, such as human health and life status monitoring in power transformers. The proposed sensor is realized by using two POFs as segmented waveguides (SW) coupled through a micro-trench milled between the fibers and then filled with a specific MIP for the 2-FAL detection. The experimental results show that the developed intensity-based sensor system is highly selective and sensitive to 2-FAL detection in aqueous solutions, with a limit of detection of about 0.04 mg L−1. The proposed sensing approach is simple and low-cost, and it shows performance comparable to that of plasmonic MIP-based sensors present in the literature for 2-FAL detection. Full article
Show Figures

Figure 1

23 pages, 24886 KiB  
Article
Corrosion Monitoring by Plastic Optic Fiber Sensor Using Bi-Directional Light Transmission
by Liang Hou and Shinichi Akutagawa
Sensors 2024, 24(10), 3229; https://doi.org/10.3390/s24103229 - 19 May 2024
Cited by 5 | Viewed by 1610
Abstract
In this paper, a new sensor is proposed to efficiently gather crucial information on corrosion phenomena and their progression within steel components. Fabricated with plastic optical fibers (POF), the sensor can detect corrosion-induced physical changes in the appearance of monitoring points within the [...] Read more.
In this paper, a new sensor is proposed to efficiently gather crucial information on corrosion phenomena and their progression within steel components. Fabricated with plastic optical fibers (POF), the sensor can detect corrosion-induced physical changes in the appearance of monitoring points within the steel material. Additionally, the new sensor incorporates an innovative structure that efficiently utilizes bi-directional optical transmission in the POF, simplifying the installation procedure and reducing the total cost of the POF cables by as much as 50% when monitoring multiple points. Furthermore, an extremely compact dummy sensor with the length of 5 mm and a diameter of 2.2 mm for corrosion-depth detection was introduced, and its functionality was validated through experiments. This paper outlines the concept and fundamental structure of the proposed sensor; analyzes the results of various experiments; and discusses its effectiveness, prospects, and economic advantages. Full article
(This article belongs to the Special Issue Specialty Optical Fiber-Based Sensors)
Show Figures

Figure 1

18 pages, 12627 KiB  
Article
Coupling of Modes in Step-Index Plastic Optical Fibers by Using D-Shape Technique
by Cláudio Márcio F. Silva, Gefeson M. Pacheco, Jognes Panasiewicz and Luis A. Rabanal Ramirez
Sensors 2024, 24(9), 2707; https://doi.org/10.3390/s24092707 - 24 Apr 2024
Cited by 1 | Viewed by 1307
Abstract
This article presents a technique for reducing the stabilization length of steady-state modes in step-index plastic optical fibers (POFs), which is significant for sensor networks, Internet of Things, signal processing, and data fusion in sensor systems. The results obtained with the com- putational [...] Read more.
This article presents a technique for reducing the stabilization length of steady-state modes in step-index plastic optical fibers (POFs), which is significant for sensor networks, Internet of Things, signal processing, and data fusion in sensor systems. The results obtained with the com- putational tool developed suggest that the D-shape created in the POF effectively reduces the stabi- lization length of the modes and, by extension, minimizes the dispersion effects of the modes by filtering out high-order modes. Applying the analysis to commercial POFs, the authors experimen- tally verified a reduction in the stabilization length of modes from 27 to 10 m and from 20 m to 5 m. Reducing the mode stabilization length minimizes the bit error rate (BER) in short-length SI-POF- based optical links operating at 250 Mbp/s. A reduction from 7.6 × 10−7 to 3.7 × 10−10 was achieved. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

13 pages, 4162 KiB  
Article
Development of an Immunocapture-Based Polymeric Optical Fiber Sensor for Bacterial Detection in Water
by Rafaela Nascimento Lopes, Paulo Henrique Silva Pinto, Juan David Lopez Vargas, Alex Dante, Andrew Macrae, Regina Célia Barros Allil and Marcelo Martins Werneck
Polymers 2024, 16(6), 861; https://doi.org/10.3390/polym16060861 - 21 Mar 2024
Cited by 6 | Viewed by 2742
Abstract
Conventional methods for pathogen detection in water rely on time-consuming enrichment steps followed by biochemical identification strategies, which require assay times ranging from 24 hours to a week. However, in recent years, significant efforts have been made to develop biosensing technologies enabling rapid [...] Read more.
Conventional methods for pathogen detection in water rely on time-consuming enrichment steps followed by biochemical identification strategies, which require assay times ranging from 24 hours to a week. However, in recent years, significant efforts have been made to develop biosensing technologies enabling rapid and close-to-real-time detection of waterborne pathogens. In previous studies, we developed a plastic optical fiber (POF) immunosensor using an optoelectronic configuration consisting of a U-Shape probe connected to an LED and a photodetector. Bacterial detection was evaluated with the immunosensor immersed in a bacterial suspension in water with a known concentration. Here, we report on the sensitivity of a new optoelectronic configuration consisting of two POF U-shaped probes, one as the reference and the other as the immunosensor, for the detection of Escherichia coli. In addition, another methos of detection was tested where the sensors were calibrated in the air, before being immersed in a bacterial suspension and then read in the air. This modification improved sensor sensitivity and resulted in a faster detection time. After the immunocapture, the sensors were DAPI-stained and submitted to confocal microscopy. The histograms obtained confirmed that the responses of the immunosensors were due to the bacteria. This new sensor detected the presence of E. coli at 104 CFU/mL in less than 20 min. Currently, sub-20 min is faster than previous studies using fiber-optic based biosensors. We report on an inexpensive and faster detection technology when compared with conventional methods. Full article
(This article belongs to the Special Issue Polymeric Biosensors: Fabrication, Characterization, and Applications)
Show Figures

Figure 1

25 pages, 7153 KiB  
Review
Protein and Polysaccharide-Based Optical Materials for Biomedical Applications
by Gianna Riviello, Brendan Connor, Jake McBrearty, Gianna Rodriguez and Xiao Hu
Int. J. Mol. Sci. 2024, 25(3), 1861; https://doi.org/10.3390/ijms25031861 - 3 Feb 2024
Cited by 5 | Viewed by 2441
Abstract
Recent advances in biomedical research, particularly in optical applications, have sparked a transformative movement towards replacing synthetic polymers with more biocompatible and sustainable alternatives. Most often made from plastics or glass, these materials ignite immune responses from the body, and their production is [...] Read more.
Recent advances in biomedical research, particularly in optical applications, have sparked a transformative movement towards replacing synthetic polymers with more biocompatible and sustainable alternatives. Most often made from plastics or glass, these materials ignite immune responses from the body, and their production is based on environmentally harsh oil-based processes. Biopolymers, including both polysaccharides and proteins, have emerged as a potential candidate for optical biomaterials due to their inherent biocompatibility, biodegradability, and sustainability, derived from their existence in nature and being recognized by the immune system. Current extraction and fabrication methods for these biomaterials, including thermal drawing, extrusion and printing, mold casting, dry-jet wet spinning, hydrogel formations, and nanoparticles, aim to create optical materials in cost-effective and environmentally friendly manners for a wide range of applications. Present and future applications include optical waveguides and sensors, imaging and diagnostics, optical fibers, and waveguides, as well as ocular implants using biopolymers, which will revolutionize these fields, specifically their uses in the healthcare industry. Full article
Show Figures

Figure 1

28 pages, 13558 KiB  
Article
Experimental Investigation for Monitoring Corrosion Using Plastic Optical Fiber Sensors
by Liang Hou, Shinichi Akutagawa, Yuki Tomoshige and Takashi Kimura
Sensors 2024, 24(3), 885; https://doi.org/10.3390/s24030885 - 29 Jan 2024
Cited by 3 | Viewed by 1899
Abstract
The timely and cost-effective identification of the onset of corrosion and its progress would be critical for effectively maintaining structural integrity. Consequently, a series of fundamental experiments were conducted to capture the corrosion process on a steel plate using a new type of [...] Read more.
The timely and cost-effective identification of the onset of corrosion and its progress would be critical for effectively maintaining structural integrity. Consequently, a series of fundamental experiments were conducted to capture the corrosion process on a steel plate using a new type of plastic optical fiber (POF) sensor. Electrolytic corrosion experiments were performed on a 5 mm thick steel plate immersed in an aqueous solution. The POF sensor installed on the upper side of the plate and directed downward detected the upward progression of the corrosion zone that formed on the underside of the plate. The results showed that the POF sensors could detect the onset of the upward-progressing corrosion front as it passed the 1 and 2 mm marks related to the thickness of the corroded zone. The POF sensors were designed to optically identify corrosion; therefore, the data obtained by these sensors could be processed using a newly developed graphic application software for smartphones and also identified by the naked eye. This method offered an easy and cost-effective solution for verifying the corrosion state of structural components. Full article
(This article belongs to the Special Issue Specialty Optical Fiber-Based Sensors)
Show Figures

Figure 1

16 pages, 5328 KiB  
Article
Sensitivity Analysis of Intensity-Modulated Plastic Optical Fiber Sensors for Effective Aging Detection in Rapeseed Transformer Oil
by Ugochukwu Elele, Azam Nekahi, Arshad Arshad, Kate McAulay and Issouf Fofana
Sensors 2023, 23(24), 9796; https://doi.org/10.3390/s23249796 - 13 Dec 2023
Cited by 3 | Viewed by 1736
Abstract
As the focus tilts toward online detection methodologies for transformer oil aging, bypassing challenges associated with traditional offline methods, such as sample contamination and misinterpretation, fiber optic sensors are gaining traction due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances that [...] Read more.
As the focus tilts toward online detection methodologies for transformer oil aging, bypassing challenges associated with traditional offline methods, such as sample contamination and misinterpretation, fiber optic sensors are gaining traction due to their compact nature, cost-effectiveness, and resilience to electromagnetic disturbances that are typical in high-voltage environments. This study delves into the sensitivity analysis of intensity-modulated plastic optical fiber sensors. The investigation encompasses key determinants such as the influence of optical source wavelengths, noise response dynamics, ramifications of varying sensing lengths, and repeatability assessments. Our findings highlight that elongating sensing length detrimentally affects both linearity response and repeatability, largely attributed to a diminished resistance to noise. Additionally, the choice of the optical source wavelength proved to be a critical variable in assessing sensor sensitivity. Full article
(This article belongs to the Special Issue Feature Papers in Fault Diagnosis & Sensors 2023)
Show Figures

Figure 1

5 pages, 2041 KiB  
Proceeding Paper
Toward the Development of Plasmonic Biosensors to Realize Point-of-Care Tests for the Detection of Viruses and Bacteria
by Francesco Arcadio, Ines Tavoletta, Chiara Marzano, Luca Pasquale Renzullo, Nunzio Cennamo and Luigi Zeni
Eng. Proc. 2023, 56(1), 113; https://doi.org/10.3390/ASEC2023-15277 - 6 Dec 2023
Cited by 1 | Viewed by 1082
Abstract
Optical fiber biosensors can be used to develop point-of-care tests (POCTs) for detecting viruses and bacteria in several matrices. In particular, the surface plasmon resonance (SPR) and localized SPR phenomena (LSPR) can be excited by exploiting low-cost and small-size optical fiber chips. Generally, [...] Read more.
Optical fiber biosensors can be used to develop point-of-care tests (POCTs) for detecting viruses and bacteria in several matrices. In particular, the surface plasmon resonance (SPR) and localized SPR phenomena (LSPR) can be excited by exploiting low-cost and small-size optical fiber chips. Generally, SPR or LSPR sensors are realized using several kinds of modified optical fibers (silica, plastic, or specialty) or by exploiting other optical waveguides (e.g., slab, spoon-shaped waveguides, etc.). More specifically, optical fiber sensors can be classified as intrinsic or extrinsic. In the “optical fiber intrinsic sensors”, the sensing area is realized in the optical fiber directly, such as in the case of plasmonic platforms based on D-shaped plastic optical fibers (POFs), tapered optical fibers, U-bend POFs, or light-diffusing fibers (LDFs). By contrast, when an optical fiber is used as a mere waveguide allowing for the launch of light to the sensing region and its collection, it is defined as an extrinsic optical fiber sensor, like in the case of the plasmonic sensors realized by Cennamo et al. using POFs combined with spoon-shaped waveguides, 3D-printed platforms, bacterial cellulose waveguides, nanogratings, and InkJet-printed chips. To realize optical biosensor chips for the detection of viruses and bacteria, both intrinsic and extrinsic plasmonic POF sensors can be efficiently combined with receptors specific for membrane proteins, either biological (e.g., antibodies, aptamers, enzymes, etc.) or synthetic (e.g., molecularly imprinted polymers), to build groundbreaking POCTs. Full article
(This article belongs to the Proceedings of The 4th International Electronic Conference on Applied Sciences)
Show Figures

Figure 1

Back to TopTop