Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = microbubble infusion

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 2681 KB  
Article
Analysing the Renal Vasculature Using Super-Resolution Ultrasound Imaging: Considerations for Clinical and Research Applications
by Amy McDermott, Nathalie Sarup Panduro, Iman Taghavi, Hans Martin Kjer, Stinne Byrholdt Søgaard, Michael Bachmann Nielsen, Jørgen Arendt Jensen and Charlotte Mehlin Sørensen
Diagnostics 2025, 15(12), 1515; https://doi.org/10.3390/diagnostics15121515 - 14 Jun 2025
Cited by 1 | Viewed by 789
Abstract
Background: Vascular imaging is essential for clinical practice, research, and the diagnosis and management of vascular diseases. Super-resolution ultrasound (SRUS) imaging is an emerging high-resolution imaging technique with broad applications in soft tissue vascular imaging. However, the impact of biological and clinical variables [...] Read more.
Background: Vascular imaging is essential for clinical practice, research, and the diagnosis and management of vascular diseases. Super-resolution ultrasound (SRUS) imaging is an emerging high-resolution imaging technique with broad applications in soft tissue vascular imaging. However, the impact of biological and clinical variables on its imaging accuracy is currently unknown. This study investigates these factors in an animal model and compares SRUS with contrast-enhanced µCT. Methods: Kidney scans from 29 Zucker rats (Zucker Diabetic Fatty and Zucker Lean) were retrospectively analysed. The left kidney was imaged in vivo using SRUS during microbubble infusion, then filled with Microfil and excised for ex vivo µCT. SRUS parameters and clinical variables were analysed, and SRUS scans were co-registered with µCT to compare vascular density measurements. Results: Mean arterial blood pressure and anaesthesia time showed significant linear relationships with SRUS microbubble detection and vascular track reconstruction. The anaesthesia time was also strongly correlated with vascular density measurement. Visualisation and velocity estimations of renal arteries were limited with SRUS. Ultrasound signal attenuation had significant impacts, particularly in cortical far-field imaging. Despite differences between kidney regions, the vascular density distribution did not differ considerably between SRUS and µCT datasets for whole-kidney imaging. Conclusions: This study outlines key factors SRUS users must consider for optimal technique use. Careful region selection and control of clinical variables ensure more reliable and comparable images. Further research is necessary to translate these findings from a rat model into clinical application. Full article
(This article belongs to the Special Issue Ultrasound Imaging in Medicine in 2025)
Show Figures

Figure 1

13 pages, 6870 KB  
Article
Intra-Arterial Super-Selective Delivery of Yttrium-90 for the Treatment of Recurrent Glioblastoma: In Silico Proof of Concept with Feasibility and Safety Analysis
by Giulia Paolani, Silvia Minosse, Silvia Strolin, Miriam Santoro, Noemi Pucci, Francesca Di Giuliano, Francesco Garaci, Letizia Oddo, Yosra Toumia, Eugenia Guida, Francesco Riccitelli, Giulia Perilli, Alessandra Vitaliti, Angelico Bedini, Susanna Dolci, Gaio Paradossi, Fabio Domenici, Valerio Da Ros and Lidia Strigari
Pharmaceutics 2025, 17(3), 345; https://doi.org/10.3390/pharmaceutics17030345 - 7 Mar 2025
Viewed by 1034
Abstract
Background: Intra-arterial cerebral infusion (IACI) of radiotherapeutics is a promising treatment for glioblastoma (GBM) recurrence. We investigated the in silico feasibility and safety of Yttrium-90-Poly(vinyl alcohol)-Microbubble (90Y-PVA-MB) IACI in patients with recurrent GBM and compared the results with those of [...] Read more.
Background: Intra-arterial cerebral infusion (IACI) of radiotherapeutics is a promising treatment for glioblastoma (GBM) recurrence. We investigated the in silico feasibility and safety of Yttrium-90-Poly(vinyl alcohol)-Microbubble (90Y-PVA-MB) IACI in patients with recurrent GBM and compared the results with those of external beam radiation therapy (EBRT). Methods: Contrast-enhanced T1-weighted magnetic resonance imaging (T1W-MRI) was used to delineate the tumor volumes and CT scans were used to automatically segment the organs at risk in nine patients with recurrent GBM. Volumetric Modulated Arc Therapy (VMAT) treatment plans were generated using a clinical treatment planning system. Assuming the relative intensity of each voxel from the MR-T1W as a valid surrogate for the post-IACI 90Y-PVA-MB distribution, a specific 90Y dose voxel kernel was obtained through Monte Carlo (MC) simulations and convolved with the MRI, resulting in a 90Y-PVA-MB-based dose distribution that was then compared with the VMAT plans. Results: The physical dose distribution obtained from the simulation of 1GBq of 90Y-PVA-MBs was rescaled to ensure that 95% of the prescribed dose was delivered to 95% or 99% of the target (i.e., A95% and A99%, respectively). The calculated activities were A95% = 269.2 [63.6–2334.1] MBq and A99% = 370.6 [93.8–3315.2] MBq, while the mean doses to the target were 58.2 [58.0–60.0] Gy for VMAT, and 123.1 [106.9–153.9] Gy and 170.1 [145.9–223.8] Gy for A95% and A99%, respectively. Additionally, non-target brain tissue was spared in the 90Y-PVA-MB treatment compared to the VMAT approach, with a median [range] of mean doses of 12.5 [12.0–23.0] Gy for VMAT, and 0.6 [0.2–1.0] Gy and 0.9 [0.3–1.5] Gy for the 90Y treatments assuming A95% and A99%, respectively. Conclusions: 90Y-PVA-MB IACI using MR-T1W appears to be feasible and safe, as it enables the delivery of higher doses to tumors and lower doses to non-target volumes compared to the VMAT approach. Full article
(This article belongs to the Special Issue CNS Drug Delivery: Recent Advances and Challenges)
Show Figures

Figure 1

26 pages, 7912 KB  
Article
Investigation of Sonication Parameters for Large-Volume Focused Ultrasound-Mediated Blood–Brain Barrier Permeability Enhancement Using a Clinical-Prototype Hemispherical Phased Array
by Dallan McMahon, Ryan M. Jones, Rohan Ramdoyal, Joey Ying Xuan Zhuang, Dallas Leavitt and Kullervo Hynynen
Pharmaceutics 2024, 16(10), 1289; https://doi.org/10.3390/pharmaceutics16101289 - 30 Sep 2024
Viewed by 2045
Abstract
Background/Objectives: Focused ultrasound (FUS) and microbubble (MB) exposure is a promising technique for targeted drug delivery to the brain; however, refinement of protocols suitable for large-volume treatments in a clinical setting remains underexplored. Methods: Here, the impacts of various sonication parameters on blood–brain [...] Read more.
Background/Objectives: Focused ultrasound (FUS) and microbubble (MB) exposure is a promising technique for targeted drug delivery to the brain; however, refinement of protocols suitable for large-volume treatments in a clinical setting remains underexplored. Methods: Here, the impacts of various sonication parameters on blood–brain barrier (BBB) permeability enhancement and tissue damage were explored in rabbits using a clinical-prototype hemispherical phased array developed in-house, with real-time 3D MB cavitation imaging for exposure calibration. Initial experiments revealed that continuous manual agitation of MBs during infusion resulted in greater gadolinium (Gd) extravasation compared to gravity drip infusion. Subsequent experiments used low-dose MB infusion with continuous agitation and a low burst repetition frequency (0.2 Hz) to mimic conditions amenable to long-duration clinical treatments. Results: Key sonication parameters—target level (proportional to peak negative pressure), number of bursts, and burst length—significantly affected BBB permeability enhancement, with all parameters displaying a positive relationship with relative Gd contrast enhancement (p < 0.01). Even at high levels of BBB permeability enhancement, tissue damage was minimal, with low occurrences of hypointensities on T2*-weighted MRI. When accounting for relative Gd contrast enhancement, burst length had a significant impact on red blood cell extravasation detected in histological sections, with 1 ms bursts producing significantly greater levels compared to 10 ms bursts (p = 0.03), potentially due to the higher pressure levels required to generate equal levels of BBB permeability enhancement. Additionally, albumin and IgG extravasation correlated strongly with relative Gd contrast enhancement across sonication parameters, suggesting that protein extravasation can be predicted from non-invasive imaging. Conclusions: These findings contribute to the development of safer and more effective clinical protocols for FUS + MB exposure, potentially improving the efficacy of the approach. Full article
(This article belongs to the Section Drug Delivery and Controlled Release)
Show Figures

Figure 1

14 pages, 3861 KB  
Article
Peritoneal Infusion of Oxygen Microbubbles Alters the Metabolomic Profile of the Lung and Spleen in Acute Hypoxic Exposure
by Christina Lisk, Alex Fan, Francesca I. Cendali, Kenta Kakiuchi, Delaney Swindle, David I. Pak, Robert Tolson, Abby Grier, Keely Buesing, Seth Zaeske, Angelo D’Alessandro, Mark A. Borden and David C. Irwin
Bioengineering 2024, 11(8), 761; https://doi.org/10.3390/bioengineering11080761 - 27 Jul 2024
Cited by 2 | Viewed by 2748
Abstract
Administration of oxygen microbubbles (OMBs) has been shown to increase oxygen and decrease carbon dioxide in systemic circulation, as well as reduce lung inflammation and promote survival in preclinical models of hypoxia caused by lung injury. However, their impact on microenvironmental oxygenation remains [...] Read more.
Administration of oxygen microbubbles (OMBs) has been shown to increase oxygen and decrease carbon dioxide in systemic circulation, as well as reduce lung inflammation and promote survival in preclinical models of hypoxia caused by lung injury. However, their impact on microenvironmental oxygenation remains unexplored. Herein, we investigated the effects of intraperitoneal administration of OMBs in anesthetized rats exposed to hypoxic ventilation (FiO2 = 0.14). Blood oxygenation and hemodynamics were evaluated over a 2 h time frame, and then organ and tissue samples were collected for hypoxic and metabolic analyses. Data showed that OMBs improved blood SaO2 (~14%) and alleviated tissue hypoxia within the microenvironment of the kidney and intestine at 2 h of hypoxia. Metabolomic analysis revealed OMBs induced metabolic differences in the cecum, liver, kidney, heart, red blood cells and plasma. Within the spleen and lung, principal component analysis showed a metabolic phenotype more comparable to the normoxic group than the hypoxic group. In the spleen, this shift was characterized by reduced levels of fatty acids and 2-hydroxygluterate, alongside increased expression of antioxidant enzymes such as glutathione and hypoxanthine. Interestingly, there was also a shuttle effect within the metabolism of the spleen from the tricarboxylic acid cycle to the glycolysis and pentose phosphate pathways. In the lung, metabolomic analysis revealed upregulation of phosphatidylethanolamine and phosphatidylcholine synthesis, indicating a potential indirect mechanism through which OMB administration may improve lung surfactant secretion and prevent alveolar collapse. In addition, cell-protective purine salvage was increased within the lung. In summary, oxygenation with intraperitoneal OMBs improves systemic blood and local tissue oxygenation, thereby shifting metabolomic profiles of the lung and spleen toward a healthier normoxic state. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Figure 1

18 pages, 3764 KB  
Article
PVA-Microbubbles as a Radioembolization Platform: Formulation and the In Vitro Proof of Concept
by Valerio Da Ros, Letizia Oddo, Yosra Toumia, Eugenia Guida, Silvia Minosse, Lidia Strigari, Silvia Strolin, Giulia Paolani, Francesca Di Giuliano, Roberto Floris, Francesco Garaci, Susanna Dolci, Gaio Paradossi and Fabio Domenici
Pharmaceutics 2023, 15(1), 217; https://doi.org/10.3390/pharmaceutics15010217 - 8 Jan 2023
Cited by 10 | Viewed by 2961
Abstract
This proof-of-concept study lays the foundations for the development of a delivery strategy for radioactive lanthanides, such as Yttrium-90, against recurrent glioblastoma. Our appealing hypothesis is that by taking advantage of the combination of biocompatible polyvinyl alcohol (PVA) microbubbles (MBs) and endovascular radiopharmaceutical [...] Read more.
This proof-of-concept study lays the foundations for the development of a delivery strategy for radioactive lanthanides, such as Yttrium-90, against recurrent glioblastoma. Our appealing hypothesis is that by taking advantage of the combination of biocompatible polyvinyl alcohol (PVA) microbubbles (MBs) and endovascular radiopharmaceutical infusion, a minimally invasive selective radioembolization can be achieved, which can lead to personalized treatments limiting off-target toxicities for the normal brain. The results show the successful formulation strategy that turns the ultrasound contrast PVA-shelled microbubbles into a microdevice, exhibiting good loading efficiency of Yttrium cargo by complexation with a bifunctional chelator. The selective targeting of Yttrium-loaded MBs on the glioblastoma-associated tumor endothelial cells can be unlocked by the biorecognition between the overexpressed αVβ3 integrin and the ligand Cyclo(Arg-Gly-Asp-D-Phe-Lys) at the PVA microbubble surface. Hence, we show the suitability of PVA MBs as selective Y-microdevices for in situ injection via the smallest (i.e., 1.2F) neurointerventional microcatheter available on the market and the accumulation of PVA MBs on the HUVEC cell line model of integrin overexpression, thereby providing ~6 × 10−15 moles of Y90 per HUVEC cell. We further discuss the potential impact of using such versatile PVA MBs as a new therapeutic chance for treating glioblastoma multiforme recurrence. Full article
(This article belongs to the Special Issue Ultrasound-Assisted Drug Delivery System)
Show Figures

Figure 1

14 pages, 1691 KB  
Article
Cavitation Feedback Control of Focused Ultrasound Blood-Brain Barrier Opening for Drug Delivery in Patients with Parkinson’s Disease
by Yuexi Huang, Ying Meng, Christopher B. Pople, Allison Bethune, Ryan M. Jones, Agessandro Abrahao, Clement Hamani, Suneil K. Kalia, Lorraine V. Kalia, Nir Lipsman and Kullervo Hynynen
Pharmaceutics 2022, 14(12), 2607; https://doi.org/10.3390/pharmaceutics14122607 - 26 Nov 2022
Cited by 31 | Viewed by 4039
Abstract
Magnetic resonance-guided focused ultrasound (MRgFUS), in conjunction with circulating microbubbles, is an emerging technology that can transiently enhance the permeability of the blood-brain barrier (BBB) locally and non-invasively to facilitate targeted drug delivery to the brain. In this clinical trial, the feasibility and [...] Read more.
Magnetic resonance-guided focused ultrasound (MRgFUS), in conjunction with circulating microbubbles, is an emerging technology that can transiently enhance the permeability of the blood-brain barrier (BBB) locally and non-invasively to facilitate targeted drug delivery to the brain. In this clinical trial, the feasibility and safety of BBB modulation in the putamen were evaluated for biweekly therapeutic agent delivery in patients with Parkinson’s disease. The performance of the clinical MRgFUS system’s cavitation feedback controller for active power modulation throughout the exposures was examined. The putamen was targeted unilaterally by an ExAblate Neuro MRgFUS system operating at 220 kHz. Definity microbubbles were infused via a saline bag gravity drip at a rate of 4 µL/kg per 5 min. A cavitation emissions-based feedback controller was employed to modulate the acoustic power automatically according to prescribed target cavitation dose levels. BBB opening was measured by Gadolinium (Gd)-enhanced T1-weighted MR imaging, and the presence of potential micro-hemorrhages induced by the exposures was assessed via T2*-weighted MR imaging. A total of 12 treatment sessions were carried out across four patients, with target cavitation dose levels ranging from 0.20–0.40. BBB permeability in the targeted putamen was elevated successfully in all treatments, with a 14% ± 6% mean increase in Gd-enhanced T1-weighted MRI signal intensity relative to the untreated contralateral side. No indications of red blood cell extravasations were observed on MR imaging scans acquired one day following each treatment session. The cavitation emissions-based feedback controller was effective in modulating acoustic power levels to ensure BBB permeability enhancement while avoiding micro-hemorrhages, however, further technical advancements are warranted to improve its performance for use across a wide variety of brain diseases. Full article
(This article belongs to the Special Issue Ultrasonic Technologies in Imaging and Drug Delivery)
Show Figures

Figure 1

13 pages, 3903 KB  
Article
Carbonated 3D-Printable Polymer Composite for Thermo-Mechanically Stable Applications
by Fareed Dawan, Melvin Givens, Lakeira Williams and Patrick Mensah
J. Manuf. Mater. Process. 2022, 6(3), 66; https://doi.org/10.3390/jmmp6030066 - 15 Jun 2022
Cited by 4 | Viewed by 3558
Abstract
In this report, we investigate the infusion of carbon dioxide into a 3D-printable photosensitive polymer. The result is a carbonated polymer composite material. In use, polymer composite materials expect to succeed where ordinary polymers and metals fail. This is due to the tailorability [...] Read more.
In this report, we investigate the infusion of carbon dioxide into a 3D-printable photosensitive polymer. The result is a carbonated polymer composite material. In use, polymer composite materials expect to succeed where ordinary polymers and metals fail. This is due to the tailorability of composite materials for specific applications. Usually, micro/nano-particulates are embedded as fillers within a polymer matrix, enhancing the overall material properties. Here, carbon dioxide (CO2) microbubbles serve as the filler within a nylon-like polymer matrix. Additive manufacturing by stereolithography (SLA) of the carbonated polymer composite proved possible using the digital light projection (DLP) 3D printing technique. Post-heat treatment using thermogravimetric analysis of the samples at elevated temperatures resulted in a 33% mass reduction, indicative of nearly complete solvent removal and curing. An initial increase in polymer carbonation duration showed a 16% increase in porosity, more stable thermal profiles, and a 40% decrease in specific heat capacity. Thermo-mechanical compressive tests on an optimal carbonated sample revealed a 70% increase in compressive strength over its neat counterpart and a peak modulus at 50 °C of 60 MPa. Such 3D-printable carbonated polymer composites may find use in applications requiring high strength-to-weight ratio thermally stable polymers and applications requiring a versatile and convenient storage medium for on-demand CO2 deposition or supercritical fluid phase transformation. Full article
Show Figures

Graphical abstract

15 pages, 2217 KB  
Review
Focused Ultrasound and Microbubbles-Mediated Drug Delivery to Brain Tumor
by Sheng-Kai Wu, Chia-Lin Tsai, Yuexi Huang and Kullervo Hynynen
Pharmaceutics 2021, 13(1), 15; https://doi.org/10.3390/pharmaceutics13010015 - 24 Dec 2020
Cited by 79 | Viewed by 8587
Abstract
The presence of blood–brain barrier (BBB) and/or blood–brain–tumor barriers (BBTB) is one of the main obstacles to effectively deliver therapeutics to our central nervous system (CNS); hence, the outcomes following treatment of malignant brain tumors remain unsatisfactory. Although some approaches regarding BBB disruption [...] Read more.
The presence of blood–brain barrier (BBB) and/or blood–brain–tumor barriers (BBTB) is one of the main obstacles to effectively deliver therapeutics to our central nervous system (CNS); hence, the outcomes following treatment of malignant brain tumors remain unsatisfactory. Although some approaches regarding BBB disruption or drug modifications have been explored, none of them reach the criteria of success. Convention-enhanced delivery (CED) directly infuses drugs to the brain tumor and surrounding tumor infiltrating area over a long period of time using special catheters. Focused ultrasound (FUS) now provides a non-invasive method to achieve this goal via combining with systemically circulating microbubbles to locally enhance the vascular permeability. In this review, different approaches of delivering therapeutic agents to the brain tumors will be discussed as well as the characterization of BBB and BBTB. We also highlight the mechanism of FUS-induced BBB modulation and the current progress of this technology in both pre-clinical and clinical studies. Full article
(This article belongs to the Special Issue Drug Delivery to Brain Tumors)
Show Figures

Figure 1

Back to TopTop