Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (68)

Search Parameters:
Keywords = low-cost electromyography

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
8 pages, 2983 KB  
Proceeding Paper
Portable Multichannel EMG Acquisition and Analysis Platform with Adaptive Detection and Machine Learning Classification for Forearm Neuromuscular Assessment
by Ramona-Geanina Cîmpan, Lucian Vacaru, Marius Prelipceanu and Dragoș-Ionuț Vicoveanu
Eng. Proc. 2026, 148(1), 43; https://doi.org/10.3390/engproc2026148043 - 6 Aug 2026
Viewed by 160
Abstract
This present paper proposes the development and validation of a low-cost, portable system for the acquisition, processing, and classification of four-channel surface electromyography (i.e., sEMG) signals recorded from the forearm. The hardware platform integrates an STM32F4 family microcontroller and BioAmp EXG Pill module. [...] Read more.
This present paper proposes the development and validation of a low-cost, portable system for the acquisition, processing, and classification of four-channel surface electromyography (i.e., sEMG) signals recorded from the forearm. The hardware platform integrates an STM32F4 family microcontroller and BioAmp EXG Pill module. The software component was developed in Python to implement an adaptive filtering method. To evaluate gesture classification performance, three machine learning classifiers (SVM, Random Forest, kNN) were compared against a classical adaptive threshold-based detection method (75th percentile of the RMS distribution). To reveal the inter-subject variability across 10 subjects, a data augmentation procedure using a Deep Convolutional Conditional Generative Adversarial Network (i.e., DCGAN) was used. The results demonstrate the superiority of machine learning (i.e., ML) classifiers (SVM: 99.86% accuracy, 5-fold CV) over the threshold-based method (33.00%) in classifying seven gestures, confirming the necessity of pattern recognition approaches for gesture discrimination in neuromotor rehabilitation applications. Full article
Show Figures

Figure 1

20 pages, 7088 KB  
Article
OpenSim–Umberger-Based Metabolic Power Stratification During the Sit-to-Walk Transition Using Interpretable Ensemble Learning
by Wanli Zang, Jiarong Wu, Jun Wu, Zhengqiu Zhang, Su Wang and Qiuxia Zhang
Bioengineering 2026, 13(7), 774; https://doi.org/10.3390/bioengineering13070774 - 3 Jul 2026
Cited by 1 | Viewed by 593
Abstract
Quantifying metabolic cost during short transitional movements is challenging because conventional metabolic measurements have limited temporal resolution. This proof-of-concept study examined whether model-derived metabolic cost during the sit-to-walk (STW) transition could be exploratorily stratified using interpretable ensemble learning. Forty-nine healthy adults completed the [...] Read more.
Quantifying metabolic cost during short transitional movements is challenging because conventional metabolic measurements have limited temporal resolution. This proof-of-concept study examined whether model-derived metabolic cost during the sit-to-walk (STW) transition could be exploratorily stratified using interpretable ensemble learning. Forty-nine healthy adults completed the STW phase of the Timed Up and Go task with synchronized three-dimensional kinematics, ground reaction forces, and eight-channel surface electromyography. Individually scaled OpenSim gait2392 models and the Umberger metabolic model were used to estimate metabolic power from seat-off to the end of the first complete gait cycle. Window-averaged metabolic power was stratified into low-, medium-, and high-cost levels. Window-level biomechanical features were extracted from kinematic, kinetic, and muscle-state time series. Seven classifiers were trained using a subject-level 7:3 train–test split and stratified five-fold cross-validation within the training set, and their probability outputs were integrated through TOPSIS-weighted classifier fusion. SHapley Additive exPlanations were used for class-specific feature attribution. The fused ensemble achieved an AUC of 0.870, F1 score of 0.703, accuracy of 0.705, and specificity of 0.853 on the independent test set. Discrimination was stronger for the low- and high-cost levels than for the medium-cost level. SHAP-based attribution highlighted force-related changes and knee-angle variability and amplitude measures as prediction-relevant biomechanical features. These findings support a model-derived, interpretable workflow for extending STW assessment from task performance to task cost, while indicating the need for further validation in larger and clinical datasets. Full article
(This article belongs to the Special Issue Artificial Intelligence in Gait Analysis and Rehabilitation)
Show Figures

Figure 1

27 pages, 1221 KB  
Article
Digital and Remote Interventions for Musculoskeletal Aging: Real-Time Muscle Strain Severity Detection Using Artificial Intelligence
by Zulaikha Fatima, Abdullah, Nida Hafeez, Rolando Quintero Téllez, Miguel Jesús Torres Ruiz, Carlos Guzmán Sánchez Mejorada, Miguel Félix Mata-Rivera and Roberto Zagal-Flores
Biosensors 2026, 16(7), 354; https://doi.org/10.3390/bios16070354 - 25 Jun 2026
Viewed by 710
Abstract
As global populations grow and technology advances, daily life is increasingly shaped by digital systems such as computers and smart devices. However, prolonged device use has contributed to increasing physical and mental health concerns, particularly those associated with poor sitting posture. Posture-related strain [...] Read more.
As global populations grow and technology advances, daily life is increasingly shaped by digital systems such as computers and smart devices. However, prolonged device use has contributed to increasing physical and mental health concerns, particularly those associated with poor sitting posture. Posture-related strain is frequently overlooked and contributes to musculoskeletal discomfort, including back, neck, shoulder, and wrist pain, and may also be associated with sleep disturbances and elevated stress levels. To the best of our knowledge and based on the existing literature, this is the first study to introduce a machine learning-based framework for advanced muscle strain severity classification using Internet of Things (IoT) devices that integrates posture monitoring and muscle strain detection into a unified low-cost framework ($23 hardware cost). The primary objective of this work is accurate classification of muscle strain severity, while real-time alerts serve as a secondary ergonomic feedback mechanism. Specifically, this study makes four major contributions. First, we created a novel dataset through real-time acquisition of electromyography (EMG) and posture signals from participants in hospital and industrial environments, capturing diverse muscle strain patterns validated against clinical assessment procedures. Second, we designed a two-part hardware architecture consisting of posture detection (PD) and strain detection (SD) modules using a NodeMCU ESP8266, HC-SR04 ultrasonic sensor, EMG sensor, and buzzer for real-time physiological monitoring, incorporating EMG-specific preprocessing including band-pass filtering, rectification, and RMS smoothing. Third, we proposed and evaluated a hybrid machine learning framework integrating Vision Transformer (ViT) and XGBoost to classify strain severity into three study-specific categories: baseline (EMG RMS < 40 µV), compensatory strain (40–59 µV), and overload (≥60 µV). These categories were used as reproducible severity proxies for machine learning annotation and should not be interpreted as universal biomarkers of structural tissue damage. Finally, the proposed framework achieved a classification accuracy of 99.0% (95% CI: 98.5–99.5%) with an inference latency of 15.2 ms. Full article
(This article belongs to the Special Issue Biosensors for Physiological Signal Monitoring)
Show Figures

Figure 1

16 pages, 15440 KB  
Article
Miniaturized Wearable System for Multimodal EEG/ECG/EMG Sensing and Real-Time Physiological Monitoring
by Yunxiang Zhang, Xueyang Meng, Chengbang Lu, Yingning He and Xiangyu Liang
Micromachines 2026, 17(6), 697; https://doi.org/10.3390/mi17060697 - 6 Jun 2026
Viewed by 691
Abstract
Real-time physiological state awareness is central to next-generation wearable computing, yet most existing electrophysiological signal acquisition platforms remain limited to single-modality sensing, high component cost, or bulky form factors that hinder everyday deployment. Here, we present a compact, low-cost wearable platform for simultaneous [...] Read more.
Real-time physiological state awareness is central to next-generation wearable computing, yet most existing electrophysiological signal acquisition platforms remain limited to single-modality sensing, high component cost, or bulky form factors that hinder everyday deployment. Here, we present a compact, low-cost wearable platform for simultaneous electroencephalography (EEG), electromyography (EMG), and electrocardiography (ECG) acquisition. The system integrates an analog front-end, a microcontroller, and a Bluetooth wireless link on a compact single-board platform (5.6 × 3.8 cm, approximately 12.8 g with the selected lithium-polymer battery installed), with an estimated bill-of-materials cost of 67.40 USD. Experimental validation across three healthy subjects, with the ECG channel additionally benchmarked against a commercial clinical-grade ambulatory ECG recorder, demonstrates that the platform captures ECG waveforms with recognizable P-QRS-T morphology under controlled recording conditions, supports reliable R-peak detection and heart rate estimation, records stable resting-state EEG spectral features, and distinguishes EMG activation from resting baseline in both time-domain amplitude and time-frequency structure. Leveraging the real-time wireless data link between the wearable hardware and a PC-hosted MATLAB environment, we further explore application-oriented signal processing scenarios. As an offline algorithm-pipeline compatibility demonstration, a CNN-based seizure detection pipeline is applied to the Bonn EEG benchmark for five-class epileptic state classification, achieving 86.60% mean classification accuracy. The proposed system offers a scalable and affordable foundation for wearable human-state-aware interaction, with potential applications in clinical monitoring, rehabilitation, and brain–computer interfaces. Full article
(This article belongs to the Special Issue Bioelectronics and Its Limitless Possibilities)
Show Figures

Figure 1

31 pages, 6034 KB  
Article
Mechatronic Design and Development of a Lower-Limb Exoskeleton System Based on Knee Joint Biomechanical Principles Using Electro-Pneumatic Actuation with an Embedded EMG Controller for Experimental Validation in Elderly Gait Rehabilitation Support
by Adrian Nacarino, Bryan Sanchez, Sandra Charapaqui, Renzo Charapaqui, Renzo R. Maldonado-Gómez, Leslie M. Mendoza-Arias, Daira de la Barra, Cristina Ccellcaro, Ricardo Palomares, Jose Cornejo, Mariela Vargas, Robert Castro and Jorge Cornejo
Bioengineering 2026, 13(6), 644; https://doi.org/10.3390/bioengineering13060644 - 29 May 2026
Cited by 1 | Viewed by 716
Abstract
Stroke is the second leading cause of death globally and a major contributor to lower-limb disability, affecting gait, balance, and functional independence in elderly populations. While robot-assisted rehabilitation has demonstrated effectiveness in motor recovery, access remains limited due to high costs and geographic [...] Read more.
Stroke is the second leading cause of death globally and a major contributor to lower-limb disability, affecting gait, balance, and functional independence in elderly populations. While robot-assisted rehabilitation has demonstrated effectiveness in motor recovery, access remains limited due to high costs and geographic barriers, particularly in Latin America. This study presents ExoKnee, a low-cost knee exoskeleton designed through biomimetic principles and 3D-printed fabrication as a proof-of-concept device targeting gait rehabilitation in elderly adults. The system integrates a single-degree-of-freedom pneumatic actuator controlled by electromyography (EMG) signals from the quadriceps muscle, enabling knee flexion and extension (90° to 180°). The design was evaluated through finite element analysis and dynamic simulations in MATLAB/Simulink R2024a under constant, stepwise, and sinusoidal reference inputs in a digital-twin environment. Expert validation using the Content Validity Coefficient yielded a mean score of 0.8747, reflecting preliminary expert agreement on the conceptual design’s coherence and relevance. The prototype demonstrated controlled movements through a 6-bar pneumatic system with EMG-triggered relay activation, validated at the proof-of-concept level through simulation and single-subject threshold calibration. ExoKnee addresses critical gaps by offering an anthropometrically informed, biosignal-driven, and locally manufacturable rehabilitation platform for low- and middle-income countries, pending clinical validation. Future work will focus on clinical trials and adaptive EMG control strategies. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Figure 1

18 pages, 5935 KB  
Article
Portable Holonomic Educational Robot Platform for Home Laboratory—Study Case: AI-Based Electromyography Control
by Erick Alexander Noboa, Lourdes Ruiz, György Eigner and Péter Galambos
Technologies 2026, 14(5), 308; https://doi.org/10.3390/technologies14050308 - 20 May 2026
Viewed by 621
Abstract
The post-pandemic evolution of education involving mechatronics and machine learning has shifted the demand for robotic hardware from centralized laboratories to accessible laboratories in home environments. This paper presents a portable three-wheeled holonomic robotic platform designed for remote research and home office experimentation. [...] Read more.
The post-pandemic evolution of education involving mechatronics and machine learning has shifted the demand for robotic hardware from centralized laboratories to accessible laboratories in home environments. This paper presents a portable three-wheeled holonomic robotic platform designed for remote research and home office experimentation. The proposed system utilizes a modular design and low-cost philosophy comprising a custom embedded control system driven by an ESP32-WROOM microcontroller, which manages a closed-loop PID velocity controller using Hall effect feedback from three DC micromotors. In contrast, external nodes allow the reception, conditioning, and classification of 8-channel surface electromyography (sEMG) data sampled at 500 Hz. To address the non-stationarity and stochastic noise in raw sEMG signals, this study implements a hybrid Deep Learning (DL) architecture that complements 2D Convolutional Neural Networks (CNN) for spatial feature extraction with Long Short-Term Memory (LSTM) networks for temporal context awareness. This model decodes the neuromuscular intent of the user into real-time holonomic velocity vectors, achieving validation accuracies of 80.51% for horizontal movement, 84.86% for vertical translation, and 99.56% for the Fist/no-Fist state. By synthesizing advanced AI-based teleoperation with a portable design, this study establishes a scalable framework for the next generation of “laboratory-at-home” educational tools and research regardless of physical location. Full article
Show Figures

Figure 1

25 pages, 5755 KB  
Article
TransTCNet: Transformer-Based Temporal-Contextual Network for Low-Latency Typing Interfaces on Edge Devices
by Asif Ullah, Zhendong Song, Waqar Riaz, Yizhi Shao and Xiaozhi Qi
Biomimetics 2026, 11(5), 337; https://doi.org/10.3390/biomimetics11050337 - 12 May 2026
Viewed by 677
Abstract
A distinct typing interface using surface electromyography (sEMG) can facilitate silent, hands-free typing by interpreting muscle activity in relation to specific keystrokes. Character-level recognition poses greater challenges than coarse gesture recognition because it is sensitive to subtle temporal variations and overlapping muscle dynamics. [...] Read more.
A distinct typing interface using surface electromyography (sEMG) can facilitate silent, hands-free typing by interpreting muscle activity in relation to specific keystrokes. Character-level recognition poses greater challenges than coarse gesture recognition because it is sensitive to subtle temporal variations and overlapping muscle dynamics. Temporal features are essential for typing recognition because keypresses may differ in duration, force, and accompanying hand movements across users. This paper proposes TransTCNet, a two-stage deep neural network architecture with a causal convolutional layer for learning local features and a transformer-based component for learning long-range temporal interactions. We evaluated our network on a publicly available 26-class typing sEMG dataset acquired from 19 individuals. The model achieved a validation accuracy of 96.53%, exceeding the baseline models. Our study revealed generalization among participants, and the AUC values were also high (>0.994) across all classes. The model was highly reliable and exhibited high prediction confidence (>0.9), enabling us to achieve a high training accuracy (97.86%) for real-time filtering decisions. TransTCNet could be suitable for wearable and edge devices due to its efficient architecture and low inference cost. The model’s ability to consistently decode fine-grained neuromuscular signals across users makes it well-suited for real-time applications such as adaptive user interfaces, virtual and augmented reality, prosthetic control, and communication systems. Full article
(This article belongs to the Section Bioinspired Sensorics, Information Processing and Control)
Show Figures

Graphical abstract

11 pages, 1114 KB  
Article
Evaluation of 3D-Printed Dry Electrodes for Surface Electromyography in Dynamic Muscle Assessment
by Ahmad O. Alokaily, Ahmed A. Aldohbeyb, Mohamed A. Almadi, Fahed K. Alnawfal, Shahad N. Alshamlan, Suhail S. Alshahrani, Khalid Alhussaini, Alaa M. Albishi, Khalid I. Aloraini, Ahmad Zahid Rao and Ziyad Aloqalaa
Micromachines 2026, 17(5), 504; https://doi.org/10.3390/mi17050504 - 22 Apr 2026
Viewed by 1029
Abstract
Surface electromyography (sEMG) is widely used to assess muscle activity in clinical and research settings. However, while conventional wet electrodes have advanced considerably in recent years, they are often limited by disposability, reduced comfort, and limited reusability. Recent advances in additive manufacturing provide [...] Read more.
Surface electromyography (sEMG) is widely used to assess muscle activity in clinical and research settings. However, while conventional wet electrodes have advanced considerably in recent years, they are often limited by disposability, reduced comfort, and limited reusability. Recent advances in additive manufacturing provide opportunities to fabricate customizable, low-cost dry electrodes using conductive filaments. This study aimed to evaluate the feasibility and signal performance of in-house-fabricated 3D-printed sEMG electrodes made from three commercially available conductive filaments, (Fili, Filaflex, and Proto-Pasta) differing in base polymer and resistivity, and compared their performance with standard wet electrodes. Surface electrodes were placed over the biceps brachii muscle, and EMG signals were recorded during concentric–eccentric elbow flexion under three loading conditions (3, 5, and 7 kg). Signal quality was assessed using EMG amplitude, signal-to-noise ratio (SNR), and background noise. The results showed no significant differences in SNR or background noise between the 3D-printed electrodes and standard wet electrodes. Among the tested materials, Proto-Pasta electrodes produced the highest mean EMG amplitudes, while Filaflex electrodes showed slightly lower background noise, although these differences were not statistically significant. Overall, the findings indicate that in-house-fabricated 3D-printed electrodes can provide signal quality comparable to conventional wet electrodes, supporting their potential use as low-cost and customizable alternatives for sEMG applications in research and wearable monitoring systems. Full article
(This article belongs to the Special Issue Wearable Biosensors: From Materials to Systems)
Show Figures

Figure 1

29 pages, 4549 KB  
Article
Smart Sensor-Driven Gait Rehabilitation Walker Using Machine Learning for Predictive Home-Based Therapy
by Gokul Manavalan, Yuval Arnon, A. N. Nithyaa and Shlomi Arnon
Sensors 2026, 26(8), 2547; https://doi.org/10.3390/s26082547 - 21 Apr 2026
Cited by 1 | Viewed by 1014
Abstract
Abnormal gait associated with neuromuscular and musculoskeletal disorders represents a growing clinical burden, particularly in aging populations. This study presents a modular, low-cost Smart Rehabilitation Walker (SRW) that integrates multimodal sensing and real-time haptic feedback to enable simultaneous gait monitoring and corrective intervention [...] Read more.
Abnormal gait associated with neuromuscular and musculoskeletal disorders represents a growing clinical burden, particularly in aging populations. This study presents a modular, low-cost Smart Rehabilitation Walker (SRW) that integrates multimodal sensing and real-time haptic feedback to enable simultaneous gait monitoring and corrective intervention in both clinical and home environments. The system combines force-sensing resistors for bilateral load symmetry assessment, inertial measurement units for fall detection, and surface electromyography (sEMG) for neuromuscular activity monitoring within a closed-loop assistive feedback architecture. A 15-day pilot study involving ten individuals with rheumatoid arthritis and clinically observed neurological gait abnormalities demonstrated measurable improvements in gait biomechanics. The Force Symmetry Index (FSI), calculated using the Robinson symmetry metric, decreased from an average of 0.9691 to 0.2019, corresponding to a 79.26% average reduction in inter-limb load asymmetry. Concurrently, sEMG measurements showed a substantial increase in neuromuscular activation (ΔEMG = 4.28), with statistical analysis confirming a significant improvement across participants (paired t-test: t(9) = 13.58, p < 0.001). To model rehabilitation trajectories, a nonlinear predictive framework based on Gaussian Process Regression achieved high predictive accuracy (R2 ≈ 0.9, with a mean RMSE of 0.0385), while providing uncertainty-aware trend estimation. Validation using an independent amyotrophic lateral sclerosis gait dataset further demonstrated the transferability of the analytical pipeline. These results highlight the potential of sensor-enabled assistive walkers as scalable platforms for quantitative gait rehabilitation, adaptive feedback, and long-term mobility monitoring. Full article
(This article belongs to the Special Issue Novel Optical Biosensors in Biomechanics and Physiology)
Show Figures

Graphical abstract

15 pages, 3786 KB  
Article
A Flexible Copper Electrode Array for High-Density Surface Electromyography
by Chaoxin Li, Chenghong Lu, Jiuqiang Li and Kai Guo
Bioengineering 2026, 13(4), 467; https://doi.org/10.3390/bioengineering13040467 - 16 Apr 2026
Cited by 1 | Viewed by 713
Abstract
Precise monitoring of forearm muscle groups is crucial for decoding motor intentions in human–machine interfaces (HMIs) and rehabilitation. However, traditional surface electromyography (sEMG) electrodes face significant challenges in densely packed muscle regions with large skin deformations, leading to severe signal crosstalk and unstable [...] Read more.
Precise monitoring of forearm muscle groups is crucial for decoding motor intentions in human–machine interfaces (HMIs) and rehabilitation. However, traditional surface electromyography (sEMG) electrodes face significant challenges in densely packed muscle regions with large skin deformations, leading to severe signal crosstalk and unstable contact. Here, we report a flexible, low-cost 16-channel copper electrode array system designed for the high-density monitoring of multiple forearm muscle activities. Through a facile fabrication process, rigid copper is transformed into a conformable sensing interface. The optimized serpentine interconnects endow the array with excellent stretchability and effectively isolate motion-induced stress, ensuring high-quality signal acquisition under complex deformations. The high-density 2 × 8 array enables the spatiotemporal mapping of distributed flexor and extensor muscle groups. Integrated with a customized wireless data acquisition system, the array successfully demonstrates real-time, multi-channel sEMG monitoring of various hand movements (e.g., fist clenching, wrist flexion/extension), clearly revealing specific muscle activation patterns. This low-cost, high-performance flexible sensor array provides a highly promising tool for complex gesture decoding, electromyographic imaging, and next-generation wearable HMIs. Full article
Show Figures

Figure 1

17 pages, 807 KB  
Article
Validation of a Low-Cost Open-Source Surface Electromyography System for Muscle Activation Assessment in Sports and Rehabilitation
by Diego Perez-Rodes, Edgar Aljaro-Arevalo, Jose M. Jimenez-Olmedo and Basilio Pueo
Appl. Sci. 2026, 16(3), 1295; https://doi.org/10.3390/app16031295 - 27 Jan 2026
Viewed by 1036
Abstract
Surface electromyography (sEMG) is widely used for neuromuscular assessment, but the high cost of commercial systems limits accessibility in sports and rehabilitation settings. This study validated a low-cost open-source sEMG device (OLI) against a commercial field reference (SHI) during dynamic and isometric knee [...] Read more.
Surface electromyography (sEMG) is widely used for neuromuscular assessment, but the high cost of commercial systems limits accessibility in sports and rehabilitation settings. This study validated a low-cost open-source sEMG device (OLI) against a commercial field reference (SHI) during dynamic and isometric knee extensions in 36 healthy adults. Three preprocessing pipelines were tested for OLI signals: RAW, global root mean square (RMS), and cycle-centered RMS. Waveform similarity was assessed using the coefficient of multiple correlation (CMC), retaining repetitions with CMC ≥ 0.80. For valid repetitions, a calibration model (SHI = a + b × OLI) and Bland–Altman analysis were applied to min–max normalized RMS and area-under-the-curve (AUC) metrics. The global RMS pipeline showed the best overall performance, retaining 81.9% of repetitions with high shape similarity (CMC = 0.92 ± 0.04). It exhibited minimal bias in RMS (−0.69; 95% CI −1.11 to −0.27), limits of agreement of approximately ±10 normalized units, and a moderate-to-high correlation (r = 0.73; 95% CI 0.69–0.77). The calibration slope (b = 0.16; 95% CI 0.15–0.17) showed moderate within-session consistency (ICC(2,1) = 0.45). These findings indicate that, with appropriate preprocessing, the open-source system provides practically acceptable agreement with a commercial reference for characterizing relative muscle activation patterns, supporting its use in applied sports and rehabilitation contexts. Full article
(This article belongs to the Special Issue Data Processing in Biomedical Devices and Sensors)
Show Figures

Figure 1

26 pages, 3626 KB  
Article
A Lightweight Frozen Multi-Convolution Dual-Branch Network for Efficient sEMG-Based Gesture Recognition
by Shengbiao Wu, Zhezhe Lv, Yuehong Li, Chengmin Fang, Tao You and Jiazheng Gui
Sensors 2026, 26(2), 580; https://doi.org/10.3390/s26020580 - 15 Jan 2026
Cited by 2 | Viewed by 717
Abstract
Gesture recognition is important for rehabilitation assistance and intelligent prosthetic control. However, surface electromyography (sEMG) signals exhibit strong non-stationarity, and conventional deep-learning models require long training time and high computational cost, limiting their use on resource-constrained devices. This study proposes a Frozen Multi-Convolution [...] Read more.
Gesture recognition is important for rehabilitation assistance and intelligent prosthetic control. However, surface electromyography (sEMG) signals exhibit strong non-stationarity, and conventional deep-learning models require long training time and high computational cost, limiting their use on resource-constrained devices. This study proposes a Frozen Multi-Convolution Dual-Branch Network (FMC-DBNet) to address these challenges. The model employs randomly initialized and fixed convolutional kernels for training-free multi-scale feature extraction, substantially reducing computational overhead. A dual-branch architecture is adopted to capture complementary temporal and physiological patterns from raw sEMG signals and intrinsic mode functions (IMFs) obtained through variational mode decomposition (VMD). In addition, positive-proportion (PPV) and global-average-pooling (GAP) statistics enhance lightweight multi-resolution representation. Experiments on the Ninapro DB1 dataset show that FMC-DBNet achieves an average accuracy of 96.4% ± 1.9% across 27 subjects and reduces training time by approximately 90% compared with a conventional trainable CNN baseline. These results demonstrate that frozen random-convolution structures provide an efficient and robust alternative to fully trained deep networks, offering a promising solution for low-power and computationally efficient sEMG gesture recognition. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

22 pages, 9389 KB  
Article
Validation of a Multimodal Wearable Device Integrating EMG and IMU Sensors for Monitoring Upper Limb Function During Tooth Brushing Activities of Daily Living
by Patrícia Santos, Filipa Marquês, Carla Quintão and Cláudia Quaresma
Sensors 2026, 26(2), 510; https://doi.org/10.3390/s26020510 - 12 Jan 2026
Cited by 1 | Viewed by 1767
Abstract
Analyzing the dynamics of muscle activation patterns and joint range of motion is essential to understanding human movement during complex tasks such as tooth brushing Activities of Daily Living (ADLs). In individuals with neuromotor impairments, accurate assessment of upper limb motor patterns plays [...] Read more.
Analyzing the dynamics of muscle activation patterns and joint range of motion is essential to understanding human movement during complex tasks such as tooth brushing Activities of Daily Living (ADLs). In individuals with neuromotor impairments, accurate assessment of upper limb motor patterns plays a critical role in rehabilitation, supporting the identification of compensatory strategies and informing clinical interventions. This study presents the validation of a previously developed novel, low-cost, wearable, and portable multimodal prototype that integrates inertial measurement units (IMU) and surface electromyography (sEMG) sensors into a single device. The system enables bilateral monitoring of arm segment kinematics and muscle activation amplitudes from six major agonist muscles during ADLs. Eleven healthy participants performed a functional task, tooth brushing, while wearing the prototype. The recorded data were compared with two established gold-standard systems, Qualisys® motion capture system and Biosignalsplux®, for validation of kinematic and electrophysiological measurements, respectively. This study provides technical insights into the device’s architecture. The developed system demonstrates potential for clinical and research applications, particularly for monitoring upper limb function and evaluating rehabilitation outcomes in populations with neurological disorders. Full article
Show Figures

Figure 1

15 pages, 3643 KB  
Article
Adaptive Myoelectric Hand Prosthesis Using sEMG—SVM Classification
by Forbes Kent, Amelinda Putri, Yosica Mariana, Intan Mahardika, Christian Harito, Grasheli Kusuma Andhini and Cokisela Christian Lumban Tobing
Prosthesis 2026, 8(1), 9; https://doi.org/10.3390/prosthesis8010009 - 9 Jan 2026
Cited by 1 | Viewed by 1885
Abstract
Background/Objectives: An individual with a hand disability, whether caused by an accident, disease, or congenital condition, may have significant problems with their daily activities, self-perception, and ability to work. Prosthetic hands can be used to restore essential hand functions, and features such [...] Read more.
Background/Objectives: An individual with a hand disability, whether caused by an accident, disease, or congenital condition, may have significant problems with their daily activities, self-perception, and ability to work. Prosthetic hands can be used to restore essential hand functions, and features such as adaptive grasps can enhance their usability. Due to noise in the sEMG signal and hardware limitations in the system, reliable myoelectric control remains a challenge for low-cost prosthetics. ESP32 microcontrollers are used in this study to develop an SVM-based sEMG classifier that addresses these issues and improves responsiveness and accuracy. A 3D-printed mechanical structure supports the prosthesis, reducing production costs and making it more accessible. Methods: The prosthetic hand is developed using an ESP32 as the microcontroller, a Myoware Muscle Sensor to detect muscle activity, and an ESP32-based control system that integrates sEMG acquisition, SVM classification, and finger actuation with FSR feedback. A surface electromyography (sEMG) method is paired with a Support Vector Machine (SVM) algorithm to help classify signals from the sensor to improve the user’s experience and finger adaptability. Results: The SVM classifier achieved 89.10% accuracy, an F1-score of 0.89, and an AUC of 0.92, with real-time testing demonstrating that the ESP32 could reliably distinguish flexion and extension signals and actuate the servo, accordingly, producing movements consistent with the kinematic simulations. Complementing this control performance, the prosthetic hand was constructed using a coupled 4 bar linkage mechanism fabricated in PLA+, selected for its superior factor of safety compared to the other tested materials, ensuring sufficient structural reliability during operation. Conclusions: The results demonstrate that SVM-based sEMG classification can be effectively implemented on low-power microcontrollers for intuitive, low-cost prosthetic control. Further work is needed to expand beyond two-class detection and increase robustness against muscle fatigue and sensor placement variability. Full article
Show Figures

Figure 1

12 pages, 813 KB  
Article
A Subject-Specific Surface EMG Model for Estimating L4/L5 Compressive Loading
by Pablo J. Dopico, Audrey Zucker-Levin, Kunal Singal and William M. Mihalko
Bioengineering 2026, 13(1), 70; https://doi.org/10.3390/bioengineering13010070 - 8 Jan 2026
Viewed by 778
Abstract
Low back pain (LBP) is a common cause of activity limitation in individuals that can result in socioeconomic costs up to $200 billion per year. Most cases of LBP lack a known underlying pathology. The L4/L5 motion segment is the most impaired lumbar [...] Read more.
Low back pain (LBP) is a common cause of activity limitation in individuals that can result in socioeconomic costs up to $200 billion per year. Most cases of LBP lack a known underlying pathology. The L4/L5 motion segment is the most impaired lumbar segment, likely due to high load-bearing function. The ability to model L4/L5 compressive loading from surface electromyography (sEMG) data during dynamic activity may add to the understanding of LBP. Eight volunteers with no history of LBP participated in this study. Muscle activity of the erector spinae, rectus abdominus, and external obliques were recorded by a wireless EMG system (Trigno, Delsys, Natick, MA, USA) during a straight-leg stoop-to-stand task. L4/L5 compressive loading was estimated using a subject-specific sEMG model and validated by comparison with an AnyBody model and publicly available data from OrthoLoad. A specific trendline showed a significant decrease in percent error of estimated force for all muscles. Significantly lower impulse values were estimated by the AnyBody model than the sEMG subject-specific model (p = 0.007). Although our sEMG model was subject to high variability, loading values largely remained within those reported in the literature. Significant variation was found comparing the sEMG model with the AnyBody model, which may validate continued development and testing of personalized measurements of L4/L5 loading. Full article
(This article belongs to the Section Biosignal Processing)
Show Figures

Figure 1

Back to TopTop