Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = endoscopic hemostatic agents

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
8 pages, 11471 KB  
Case Report
Emergency Endoscopic Hemostasis for Gastrointestinal Bleeding Using a Self-Assembling Peptide: A Case Series
by Takashi Murakami, Eiji Kamba, Keiichi Haga, Yoichi Akazawa, Hiroya Ueyama, Tomoyoshi Shibuya, Mariko Hojo and Akihito Nagahara
Medicina 2023, 59(5), 931; https://doi.org/10.3390/medicina59050931 - 12 May 2023
Cited by 11 | Viewed by 5647
Abstract
Background and Objectives: A novel synthetic self-assembling peptide, PuraStat, has been introduced as a hemostatic agent. This case series aimed to evaluate the clinical efficacy of PuraStat for gastrointestinal bleeding during emergency endoscopy. Cases: Twenty-five patients with gastrointestinal bleeding who had [...] Read more.
Background and Objectives: A novel synthetic self-assembling peptide, PuraStat, has been introduced as a hemostatic agent. This case series aimed to evaluate the clinical efficacy of PuraStat for gastrointestinal bleeding during emergency endoscopy. Cases: Twenty-five patients with gastrointestinal bleeding who had undergone emergency endoscopy with PuraStat between August 2021 and December 2022 were retrospectively examined. Six patients were receiving antithrombotic agents, and ten patients with refractory gastrointestinal bleeding had undergone at least one endoscopic hemostatic procedure. The breakdown of bleeding was gastroduodenal ulcer/erosion in 12 cases, bleeding after gastroduodenal or colorectal endoscopic resection in 4 cases, rectal ulcer in 2 cases, postoperative anastomotic ulcer in 2 cases, and gastric cancer, diffuse antral vascular ectasia, small intestinal ulcer, colonic diverticular bleeding, and radiation proctitis in each case. The method of hemostasis was only PuraStat application in six cases, and hemostasis in combination with high-frequency hemostatic forceps, hemostatic clip, argon plasma coagulation, and hemostatic agents (i.e., thrombin) in the remaining cases. Rebleeding was observed in three cases. Hemostatic efficiency was observed in 23 cases (92%). Conclusions: PuraStat has the expected hemostatic effect on gastrointestinal bleeding during emergency endoscopy. The use of PuraStat should be considered in emergency endoscopic hemostasis of gastrointestinal bleeding. Full article
(This article belongs to the Section Emergency Medicine)
Show Figures

Figure 1

12 pages, 2611 KB  
Article
The Use of PuraStat® in the Management of Walled-Off Pancreatic Necrosis Drained Using Lumen-Apposing Metal Stents: A Case Series
by Cecilia Binda, Alessandro Fugazza, Stefano Fabbri, Chiara Coluccio, Alessandro Repici, Ilaria Tarantino, Andrea Anderloni and Carlo Fabbri
Medicina 2023, 59(4), 750; https://doi.org/10.3390/medicina59040750 - 12 Apr 2023
Cited by 9 | Viewed by 4181
Abstract
Background and Objectives: Bleeding is one of the most feared and frequent adverse events in the case of EUS-guided drainage of WOPN using lumen-apposing metal stents (LAMSs) and of direct endoscopic necrosectomy (DEN). When it occurs, its management is still controversial. In [...] Read more.
Background and Objectives: Bleeding is one of the most feared and frequent adverse events in the case of EUS-guided drainage of WOPN using lumen-apposing metal stents (LAMSs) and of direct endoscopic necrosectomy (DEN). When it occurs, its management is still controversial. In the last few years, PuraStat, a novel hemostatic peptide gel has been introduced, expanding the toolbox of the endoscopic hemostatic agents. The aim of this case series was to evaluate the safety and efficacy of PuraStat in preventing and controlling bleeding of WOPN drainage using LAMSs. Materials and Methods: This is a multicenter, retrospective pilot study from three high-volume centers in Italy, including all consecutive patients treated with the novel hemostatic peptide gel after LAMSs placement for the drainage of symptomatic WOPN between 2019 and 2022. Results: A total of 10 patients were included. All patients underwent at least one session of DEN. Technical success of PuraStat was achieved in 100% of patients. In seven cases PuraStat was placed for post-DEN bleeding prevention, with one patient experiencing bleeding after DEN. In three cases, on the other hand, PuraStat was placed to manage active bleeding: two cases of oozing were successfully controlled with gel application, and a massive spurting from a retroperitoneal vessel required subsequent angiography. No re-bleeding occurred. No PuraStat-related adverse events were reported. Conclusions: This novel peptide gel could represent a promising hemostatic device, both in preventing and managing active bleeding after EUS-guided drainage of WON. Further prospective studies are needed to confirm its efficacy. Full article
(This article belongs to the Special Issue Digestive Endoscopy: Inside the Evidence and Outside)
Show Figures

Figure 1

9 pages, 212 KB  
Review
Endoscopic Ultrasound-Guided Treatments for Non-Variceal Upper GI Bleeding: A Review of the Literature
by Claudio Giovanni De Angelis, Pablo Cortegoso Valdivia, Stefano Rizza, Ludovica Venezia, Felice Rizzi, Marcantonio Gesualdo, Giorgio Maria Saracco and Rinaldo Pellicano
J. Clin. Med. 2020, 9(3), 866; https://doi.org/10.3390/jcm9030866 - 21 Mar 2020
Cited by 21 | Viewed by 4468
Abstract
Endoscopic injection of glues, clotting factors, or sclerosing agents is a well-known therapy for the treatment of non-variceal upper gastrointestinal bleeding (NVUGIB), but less is known about endoscopic ultrasound (EUS)-guided treatments. In this setting, literature data are scarce, and no randomized controlled trials [...] Read more.
Endoscopic injection of glues, clotting factors, or sclerosing agents is a well-known therapy for the treatment of non-variceal upper gastrointestinal bleeding (NVUGIB), but less is known about endoscopic ultrasound (EUS)-guided treatments. In this setting, literature data are scarce, and no randomized controlled trials are available. We performed a review of the existing literature in order to evaluate the role of EUS-guided therapies in the management of NVUGIB. The most common treated lesions were Dieulafoy’s lesions, pancreatic pseudoaneurysms, and gastrointestinal stromal tumors (GISTs). Mostly, the treatments were performed as a salvage option after failure of conventional endoscopic hemostatic attempts, showing good efficacy and a good safety profile, also documented by Doppler monitoring of treated lesions. EUS-guided therapies may be an effective option in the treatment of refractory NVUGIB, thus avoiding radiological or surgical management. Nevertheless, available literature still lacks robust data. Full article
(This article belongs to the Special Issue New Trends and Advances in Non-Variceal Gastrointestinal Bleeding)
22 pages, 439 KB  
Review
Biomaterials in Gastroenterology: A Critical Overview
by Adrian Goldis, Ramona Goldis and Traian V. Chirila
Medicina 2019, 55(11), 734; https://doi.org/10.3390/medicina55110734 - 12 Nov 2019
Cited by 15 | Viewed by 5614
Abstract
In spite of the large diversity of diagnostic and interventional devices associated with gastrointestinal endoscopic procedures, there is little information on the impact of the biomaterials (metals, polymers) contained in these devices upon body tissues and, indirectly, upon the treatment outcomes. Other biomaterials [...] Read more.
In spite of the large diversity of diagnostic and interventional devices associated with gastrointestinal endoscopic procedures, there is little information on the impact of the biomaterials (metals, polymers) contained in these devices upon body tissues and, indirectly, upon the treatment outcomes. Other biomaterials for gastroenterology, such as adhesives and certain hemostatic agents, have been investigated to a greater extent, but the information is fragmentary. Much of this situation is due to the paucity of details disclosed by the manufacturers of the devices. Moreover, for most of the applications in the gastrointestinal (GI) tract, there are no studies available on the biocompatibility of the device materials when in intimate contact with mucosae and other components of the GI tract. We have summarized the current situation with a focus on aspects of biomaterials and biocompatibility related to the device materials and other agents, with an emphasis on the GI endoscopic procedures. Procedures and devices used for the control of bleeding, for polypectomy, in bariatrics, and for stenting are discussed, particularly dwelling upon the biomaterial-related features of each application. There are indications that research is progressing steadily in this field, and the establishment of the subdiscipline of “gastroenterologic biomaterials” is not merely a remote projection. Upon the completion of this article, the gastroenterologist should be able to understand the nature of biomaterials and to achieve a suitable and beneficial perception of their significance in gastroenterology. Likewise, the biomaterialist should become aware of the specific tasks that the biomaterials must fulfil when placed within the GI tract, and regard such applications as both a challenge and an incentive for progressing the research in this field. Full article
Back to TopTop