Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (14)

Search Parameters:
Keywords = electric cell-substrate impedance sensing (ECIS) system

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 9465 KiB  
Article
Impedance Measurement for the Monitoring of In Vitro Cells Cultured in the Presence of Electromagnetic Waves
by Andrzej Kociubiński, Aleksandra Wilczyńska, Paweł A. Mazurek, Dominika Pigoń-Zając, Teresa Małecka-Massalska and Monika Prendecka-Wróbel
Appl. Sci. 2023, 13(3), 1267; https://doi.org/10.3390/app13031267 - 17 Jan 2023
Cited by 1 | Viewed by 2128
Abstract
This paper explores the possibility of using the impedance measurement method used to monitor morphological changes in culture cells for use in cultures in the presence of an electromagnetic field generated by a mobile phone. For this purpose, we used Electric Cell–Substrate Impedance [...] Read more.
This paper explores the possibility of using the impedance measurement method used to monitor morphological changes in culture cells for use in cultures in the presence of an electromagnetic field generated by a mobile phone. For this purpose, we used Electric Cell–Substrate Impedance Sensing (ECIS), which is a real-time, label-free, impedance-based method to study cell behaviors in tissue culture. As part of the work, a device enabling the connection in a climatic chamber was prepared without the need to interfere with environmental conditions, and a test culture of mouse fibroblasts was performed. The device based on the Arduino UNO programmable platform worked like a mobile phone. During cell proliferation, it was connected to the device three times and a change in electrical parameters in the measuring system was observed. During the phone call, there was a clear change in the values of the measured parameters. However, analysis of the obtained results indicated that there was little or no effect of the presence of the electromagnetic field on the cell culture, while the observed changes in the values of impedance, resistance, and capacitance are most likely due to the separation of positive and negative medium ions in the electromagnetic field. The application of the presented method seems possible; however, in order to eliminate the separation of ions, a different type of antenna should be designed to emit a homogeneous field to the entire well. Full article
(This article belongs to the Section Biomedical Engineering)
Show Figures

Figure 1

11 pages, 1605 KiB  
Article
Antiproliferative Properties of Triterpenoids by ECIS Method—A New Promising Approach in Anticancer Studies?
by Anna Hordyjewska, Monika Prendecka-Wróbel, Łukasz Kurach, Anna Horecka, Anna Olszewska, Dominika Pigoń-Zając, Teresa Małecka-Massalska and Jacek Kurzepa
Molecules 2022, 27(10), 3150; https://doi.org/10.3390/molecules27103150 - 14 May 2022
Cited by 6 | Viewed by 2563
Abstract
Electric cell–substrate impedance sensing is an advanced in vitro impedance measuring system which uses alternating current to determine behavior of cells in physiological conditions. In this study, we used the abovementioned method for checking the anticancer activities of betulin and betulinic acid, which [...] Read more.
Electric cell–substrate impedance sensing is an advanced in vitro impedance measuring system which uses alternating current to determine behavior of cells in physiological conditions. In this study, we used the abovementioned method for checking the anticancer activities of betulin and betulinic acid, which are some of the most commonly found triterpenes in nature. In our experiment, the threshold concentrations of betulin required to elicit antiproliferative effects, verified by MTT and LDH release methods, were 7.8 µM for breast cancer (T47D), 9.5 µM for lung carcinoma (A549), and 21.3 µM for normal epithelial cells (Vero). The ECIS results revealed the great potential of betulin and betulinic acid’s antitumor properties and their maintenance of cytotoxic substances to the breast cancer T47D line. Moreover, both substances showed a negligible toxic effect on healthy epithelial cells (Vero). Our investigation showed that the ECIS method is a proper alternative to the currently used assay for testing in vitro anticancer activity of compounds, and that it should thus be introduced in cellular routine research. It is also a valuable tool for live-monitoring changes in the morphology and physiology of cells, which translates into the accurate development of anticancer therapies. Full article
(This article belongs to the Special Issue A Feasible Approach for Natural Products to Treatment of Diseases)
Show Figures

Graphical abstract

14 pages, 2701 KiB  
Article
ECIS Based Electric Fence Method for Measurement of Human Keratinocyte Migration on Different Substrates
by Yu-Han Hung, Wei-Chih Chiu, Shyh-Rong Fuh, Yi-Ting Lai, Tse-Hua Tung, Chun-Chung Huang and Chun-Min Lo
Biosensors 2022, 12(5), 293; https://doi.org/10.3390/bios12050293 - 3 May 2022
Cited by 9 | Viewed by 4243
Abstract
Electric Cell-substrate Impedance Sensing (ECIS) is an impedance-based, real-time, and label-free measuring system for monitoring cellular activities in tissue culture. Previously, ECIS wound healing assay has been used to wound cells with high electric current and monitor the subsequent cell migration. In this [...] Read more.
Electric Cell-substrate Impedance Sensing (ECIS) is an impedance-based, real-time, and label-free measuring system for monitoring cellular activities in tissue culture. Previously, ECIS wound healing assay has been used to wound cells with high electric current and monitor the subsequent cell migration. In this study, we applied ECIS electric fence (EF) method, an alternative to electrical wounding, to assess the effects of different surface coatings on human keratinocyte (HaCaT) migration. The EF prevents inoculated cells from attaching or migrating to the fenced electrode surface while maintaining the integrity of the surface coating. After the EF is turned off, cells migrate into the cell-free area, and the increase in measured impedance is monitored. We cultured HaCaT cells on gold electrodes without coating or coated with poly-L-lysin (PLL), poly-D-lysine (PDL), or type-I collagen. We quantified migration rates according to the different slopes in the impedance time series. It was observed that either poly-L-lysine (PLL) or poly-D-lysine (PDL) limits cell adhesion and migration rates. Furthermore, the surface charge of the coated substrate in the culture condition positively correlates with the cell adhesion and migration process. Our results indicate that the EF method is useful for determining cell migration rates on specific surface coatings. Full article
(This article belongs to the Special Issue Electrochemical (Bio-) Sensors in Biological Applications)
Show Figures

Figure 1

14 pages, 2355 KiB  
Article
Modelling and Differential Quantification of Electric Cell-Substrate Impedance Sensing Growth Curves
by Anna Ronja Dorothea Binder, Andrej-Nikolai Spiess and Michael W. Pfaffl
Sensors 2021, 21(16), 5286; https://doi.org/10.3390/s21165286 - 5 Aug 2021
Cited by 10 | Viewed by 3117
Abstract
Measurement of cell surface coverage has become a common technique for the assessment of growth behavior of cells. As an indirect measurement method, this can be accomplished by monitoring changes in electrode impedance, which constitutes the basis of electric cell-substrate impedance sensing (ECIS). [...] Read more.
Measurement of cell surface coverage has become a common technique for the assessment of growth behavior of cells. As an indirect measurement method, this can be accomplished by monitoring changes in electrode impedance, which constitutes the basis of electric cell-substrate impedance sensing (ECIS). ECIS typically yields growth curves where impedance is plotted against time, and changes in single cell growth behavior or cell proliferation can be displayed without significantly impacting cell physiology. To provide better comparability of ECIS curves in different experimental settings, we developed a large toolset of R scripts for their transformation and quantification. They allow importing growth curves generated by ECIS systems, edit, transform, graph and analyze them while delivering quantitative data extracted from reference points on the curve. Quantification is implemented through three different curve fit algorithms (smoothing spline, logistic model, segmented regression). From the obtained models, curve reference points such as the first derivative maximum, segmentation knots and area under the curve are then extracted. The scripts were tested for general applicability in real-life cell culture experiments on partly anonymized cell lines, a calibration setup with a cell dilution series of impedance versus seeded cell number and finally IPEC-J2 cells treated with 1% and 5% ethanol. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

13 pages, 4788 KiB  
Article
Comparison of Leading Biosensor Technologies to Detect Changes in Human Endothelial Barrier Properties in Response to Pro-Inflammatory TNFα and IL1β in Real-Time
by James J. W. Hucklesby, Akshata Anchan, Simon J. O'Carroll, Charles P. Unsworth, E. Scott Graham and Catherine E. Angel
Biosensors 2021, 11(5), 159; https://doi.org/10.3390/bios11050159 - 18 May 2021
Cited by 11 | Viewed by 3769
Abstract
Electric Cell-Substrate Impedance Sensing (ECIS), xCELLigence and cellZscope are commercially available instruments that measure the impedance of cellular monolayers. Despite widespread use of these systems individually, direct comparisons between these platforms have not been published. To compare these instruments, the responses of human [...] Read more.
Electric Cell-Substrate Impedance Sensing (ECIS), xCELLigence and cellZscope are commercially available instruments that measure the impedance of cellular monolayers. Despite widespread use of these systems individually, direct comparisons between these platforms have not been published. To compare these instruments, the responses of human brain endothelial monolayers to TNFα and IL1β were measured on all three platforms simultaneously. All instruments detected transient changes in impedance in response to the cytokines, although the response magnitude varied, with ECIS being the most sensitive. ECIS and cellZscope were also able to attribute responses to particular endothelial barrier components by modelling the multifrequency impedance data acquired by these instruments; in contrast the limited frequency xCELLigence data cannot be modelled. Consistent with its superior impedance sensing, ECIS exhibited a greater capacity than cellZscope to distinguish between subtle changes in modelled endothelial monolayer properties. The reduced resolving ability of the cellZscope platform may be due to its electrode configuration, which is necessary to allow access to the basolateral compartment, an important advantage of this instrument. Collectively, this work demonstrates that instruments must be carefully selected to ensure they are appropriate for the experimental questions being asked when assessing endothelial barrier properties. Full article
Show Figures

Figure 1

17 pages, 5483 KiB  
Article
Real-Time Monitoring the Effect of Cytopathic Hypoxia on Retinal Pigment Epithelial Barrier Functionality Using Electric Cell-Substrate Impedance Sensing (ECIS) Biosensor Technology
by Michael H. Guerra, Thangal Yumnamcha, Abdul-Shukkur Ebrahim, Elizabeth A. Berger, Lalit Pukhrambam Singh and Ahmed S. Ibrahim
Int. J. Mol. Sci. 2021, 22(9), 4568; https://doi.org/10.3390/ijms22094568 - 27 Apr 2021
Cited by 18 | Viewed by 4100
Abstract
Disruption of retinal pigment epithelial (RPE barrier integrity is a hallmark feature of various retinal blinding diseases, including diabetic macular edema and age-related macular degeneration, but the underlying causes and pathophysiology are not completely well-defined. One of the most conserved phenomena in biology [...] Read more.
Disruption of retinal pigment epithelial (RPE barrier integrity is a hallmark feature of various retinal blinding diseases, including diabetic macular edema and age-related macular degeneration, but the underlying causes and pathophysiology are not completely well-defined. One of the most conserved phenomena in biology is the progressive decline in mitochondrial function with aging leading to cytopathic hypoxia, where cells are unable to use oxygen for energy production. Therefore, this study aimed to thoroughly investigate the role of cytopathic hypoxia in compromising the barrier functionality of RPE cells. We used Electric Cell-Substrate Impedance Sensing (ECIS) system to monitor precisely in real time the barrier integrity of RPE cell line (ARPE-19) after treatment with various concentrations of cytopathic hypoxia-inducing agent, Cobalt(II) chloride (CoCl2). We further investigated how the resistance across ARPE-19 cells changes across three separate parameters: Rb (the electrical resistance between ARPE-19 cells), α (the resistance between the ARPE-19 and its substrate), and Cm (the capacitance of the ARPE-19 cell membrane). The viability of the ARPE-19 cells and mitochondrial bioenergetics were quantified with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay and seahorse technology, respectively. ECIS measurement showed that CoCl2 reduced the total impedance of ARPE-19 cells in a dose dependent manner across all tested frequencies. Specifically, the ECIS program’s modelling demonstrated that CoCl2 affected Rb as it begins to drastically decrease earlier than α or Cm, although ARPE-19 cells’ viability was not compromised. Using seahorse technology, all three concentrations of CoCl2 significantly impaired basal, maximal, and ATP-linked respirations of ARPE-19 cells but did not affect proton leak and non-mitochondrial bioenergetic. Concordantly, the expression of a major paracellular tight junction protein (ZO-1) was reduced significantly with CoCl2-treatment in a dose-dependent manner. Our data demonstrate that the ARPE-19 cells have distinct dielectric properties in response to cytopathic hypoxia in which disruption of barrier integrity between ARPE-19 cells precedes any changes in cells’ viability, cell-substrate contacts, and cell membrane permeability. Such differences can be used in screening of selective agents that improve the assembly of RPE tight junction without compromising other RPE barrier parameters. Full article
(This article belongs to the Special Issue Retinal Function and Morphology in Health, Aging and Disease)
Show Figures

Figure 1

10 pages, 1069 KiB  
Proceeding Paper
Comparison of Leading Biosensor Technologies to Measure Endothelial Adhesion, Barrier Properties, and Responses to Cytokines in Real-Time
by James J. W. Hucklesby, Akshata Anchan, Simon J. O’Carroll, Catherine E. Angel and E. Scott Graham
Proceedings 2020, 60(1), 62; https://doi.org/10.3390/IECB2020-07036 - 2 Nov 2020
Viewed by 1930
Abstract
Electric Cell-substrate Impedance Sensing (ECIS), xCELLigence and cellZscope are commercially available instruments which are able to measure the impedance of cellular monolayers continuously and with high precision. The small currents used allow the label-free, real-time monitoring of the cells in a non-invasive manner. [...] Read more.
Electric Cell-substrate Impedance Sensing (ECIS), xCELLigence and cellZscope are commercially available instruments which are able to measure the impedance of cellular monolayers continuously and with high precision. The small currents used allow the label-free, real-time monitoring of the cells in a non-invasive manner. Despite the widespread use of these systems individually, direct comparisons between the systems have not been published. In order to compare the sensitivity of the instruments, the responses of the brain microvascular endothelial cell line hCMVEC to the inflammatory cytokines TNFα and IL1β were measured on all three instruments simultaneously. All three instruments showed transient decreases, followed by prolonged increases in impedance. Although xCELLigence could detect these changes, it was unable to determine which component of the barrier was affected. In contrast, ECIS and cellZscope were both able to attribute responses to particular barrier components, and ECIS had a higher sensitivity than cellZscope. Finally, as cellZscope uses Transwells, it allows access to the basolateral compartment, an important advantage of this technology. Furthermore, although xCELLigence readings are equivalent to ECIS, the reduced frequency range greatly limits interpretation. This work demonstrates that instruments must be carefully selected in order to ensure that they are appropriate for the experimental questions being asked. Full article
(This article belongs to the Proceedings of The 1st International Electronic Conference on Biosensors)
Show Figures

Figure 1

16 pages, 5381 KiB  
Article
Bone Morphogenetic Protein (BMP)4 But Not BMP2 Disrupts the Barrier Integrity of Retinal Pigment Epithelia and Induces Their Migration: A Potential Role in Neovascular Age-Related Macular Degeneration
by Ahmed S. Ibrahim, Khaled Hussein, Fang Wang, Ming Wan, Nancy Saad, Maamon Essa, Ivana Kim, Akbar Shakoor, Leah A. Owen, Margaret M. DeAngelis and Mohamed Al-Shabrawey
J. Clin. Med. 2020, 9(7), 2293; https://doi.org/10.3390/jcm9072293 - 19 Jul 2020
Cited by 14 | Viewed by 4533
Abstract
Disruption of retinal pigment epithelial (RPE) barrier integrity and RPE migration are hallmark features in neovascular age-related macular degeneration (nAMD), but the underlying causes and pathophysiology are not completely well-defined. Herein, we aimed to evaluate the effect of bone morphogenetic proteins (BMPs) on [...] Read more.
Disruption of retinal pigment epithelial (RPE) barrier integrity and RPE migration are hallmark features in neovascular age-related macular degeneration (nAMD), but the underlying causes and pathophysiology are not completely well-defined. Herein, we aimed to evaluate the effect of bone morphogenetic proteins (BMPs) on the barrier function and migration of RPE. In particular, we investigated the role of BMP2 and BMP4 in these processes as our analysis of RNA-sequencing (seq) data from human donor eyes demonstrated that they are highly differentially expressed BMP members in macular RPE/choroid versus macular retina. We used electrical cell-substrate impedance sensing (ECIS) system to monitor precisely in real time the barrier integrity and migration of ARPE-19 after treatment with various concentrations of BMP2 or BMP4. Immunofluorescence was also used to assess the changes in the expression and the organization of the key tight junction protein, zona occludens (ZO)-1, in ARPE-19 cells under BMP2 or BMP4 treatment. This was followed by measuring the activity of matrix metalloproteinases (MMPs). Finally, RNA-seq and ELISA were used to determine the local and circulating levels of BMP2 and BMP4 in retinas and serum samples from nAMD donors. Our ECIS results showed that BMP4 but not BMP2 decreased the transcellular electrical resistance (TER) of ARPE-19 and increased their migration in comparison with control (vehicle-treated cells). Furthermore, immunofluorescence showed a disorganization of ZO-1 in BMP4-treated ARPE-19 not in BMP2-treated cells or vehicle-treated controls. This effect of BMP4 was associated with significant increases in the activity of MMPs, specifically MMP2. Lastly, these results were corroborated by additional findings that circulating but not local BMP4 levels were significantly higher in nAMD donor samples compared to controls. Collectively, our results demonstrated unreported effects of BMP4 on inducing RPE dysfunction and suggest that BMP4 but not BMP2 may represent a potential therapeutic target in nAMD. Full article
(This article belongs to the Special Issue Prevention and Treatments of Age-Related Macular Degeneration)
Show Figures

Figure 1

13 pages, 4035 KiB  
Article
Electrochemical Assessment of Anticancer Compounds on the Human Tongue Squamous Carcinoma Cells
by Chun-Chung Huang, Tse-Hua Tung, Chien-Chu Huang, Shao-Yi Lin, Shih-Chi Chao, Sheng-Po Chiu, Shiao-Pieng Lee and Chun-Min Lo
Sensors 2020, 20(9), 2632; https://doi.org/10.3390/s20092632 - 5 May 2020
Cited by 14 | Viewed by 3561
Abstract
The most common oral cancer is squamous cell carcinoma (SCC) and its highest occurrence is in the tongue. Almost 30% of patients with one primary head and neck tumor will have a second primary malignancy. In recent studies, two novel plant extracts, andrographolide [...] Read more.
The most common oral cancer is squamous cell carcinoma (SCC) and its highest occurrence is in the tongue. Almost 30% of patients with one primary head and neck tumor will have a second primary malignancy. In recent studies, two novel plant extracts, andrographolide and cannabidiol (CBD), have been exploited for their anticancer effects. Here, we investigated the cytotoxic effects of these two compounds on SCC-25 cells, a human tongue squamous carcinoma cell line, and compared the outcomes with two chemotherapeutic drugs, cisplatin and fluorouracil. Electric cell substrate impedance sensing (ECIS) system was applied to measure frequency- and time-dependent impedance of SCC-25 cell-covered electrodes and to further assess subtle changes in cell morphology and micromotion in response to different concentrations (0, 10, 30, 100, and 300 µM) of these compounds. AlamarBlue and Annexin V/7-AAD binding assays were used to measure the concentration dependent changes in viability and apoptosis of SCC-25 cells. Our results demonstrate that 24 hours after exposure to 30 µM CBD can significantly decrease the micromotion rate, damage the integrity of cell morphology, reduce cell viability, and induce higher apoptosis in treated SCC-25 cells, while the other three drugs attain similar effects at the concentration of 100 µM or higher. The apoptosis-induced changes in cell morphology and micromotion monitored by ECIS correlate well with biochemical assays. Thus, both frequency- and time-dependent impedance measurements using ECIS can be used to real-time follow cancer cell activities in response to anticancer drugs with different temporal cytotoxicity profiles. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

10 pages, 4343 KiB  
Article
Assessment of Cytotoxicity of Magnesium Oxide and Magnesium Hydroxide Nanoparticles using the Electric Cell-Substrate Impedance Sensing
by Manishi Pallavi, Jenora Waterman, Youngmi Koo, Jagannathan Sankar and Yeoheung Yun
Appl. Sci. 2020, 10(6), 2114; https://doi.org/10.3390/app10062114 - 20 Mar 2020
Cited by 6 | Viewed by 2548
Abstract
Magnesium (Mg)-based alloys have the potential for bone repair due to their properties of biodegradation, biocompatibility, and structural stability, which can eliminate the requirement for a second surgery for the removal of the implant. Nevertheless, uncontrolled degradation rate and possible cytotoxicity of the [...] Read more.
Magnesium (Mg)-based alloys have the potential for bone repair due to their properties of biodegradation, biocompatibility, and structural stability, which can eliminate the requirement for a second surgery for the removal of the implant. Nevertheless, uncontrolled degradation rate and possible cytotoxicity of the corrosion products at the implant sites are known current challenges for clinical applications. In this study, we assessed in vitro cytotoxicity of different concentrations (0 to 50 mM) of possible corrosion products in the form of magnesium oxide (MgO) and magnesium hydroxide (Mg(OH)2) nanoparticles (NPs) in human fetal osteoblast (hFOB) 1.19 cells. We measured cell proliferation, adhesion, migration, and cytotoxicity using a real-time, label-free, non-invasive electric cell-substrate impedance sensing (ECIS) system. Our results suggest that 1 mM concentrations of MgO/Mg(OH)2 NPs are tolerable in hFOB 1.19 cells. Based on our findings, we propose the development of innovative biodegradable Mg-based alloys for further in vivo animal testing and clinical trials in orthopedics. Full article
(This article belongs to the Section Applied Biosciences and Bioengineering)
Show Figures

Figure 1

10 pages, 2898 KiB  
Article
Data-Analytics Modeling of Electrical Impedance Measurements for Cell Culture Monitoring
by Elvira García, Pablo Pérez, Alberto Olmo, Roberto Díaz, Gloria Huertas and Alberto Yúfera
Sensors 2019, 19(21), 4639; https://doi.org/10.3390/s19214639 - 25 Oct 2019
Cited by 10 | Viewed by 4882
Abstract
High-throughput data analysis challenges in laboratory automation and lab-on-a-chip devices’ applications are continuously increasing. In cell culture monitoring, specifically, the electrical cell-substrate impedance sensing technique (ECIS), has been extensively used for a wide variety of applications. One of the main drawbacks of ECIS [...] Read more.
High-throughput data analysis challenges in laboratory automation and lab-on-a-chip devices’ applications are continuously increasing. In cell culture monitoring, specifically, the electrical cell-substrate impedance sensing technique (ECIS), has been extensively used for a wide variety of applications. One of the main drawbacks of ECIS is the need for implementing complex electrical models to decode the electrical performance of the full system composed by the electrodes, medium, and cells. In this work we present a new approach for the analysis of data and the prediction of a specific biological parameter, the fill-factor of a cell culture, based on a polynomial regression, data-analytic model. The method was successfully applied to a specific ECIS circuit and two different cell cultures, N2A (a mouse neuroblastoma cell line) and myoblasts. The data-analytic modeling approach can be used in the decoding of electrical impedance measurements of different cell lines, provided a representative volume of data from the cell culture growth is available, sorting out the difficulties traditionally found in the implementation of electrical models. This can be of particular importance for the design of control algorithms for cell cultures in tissue engineering protocols, and labs-on-a-chip and wearable devices applications. Full article
(This article belongs to the Special Issue Data Analysis for Smart Sensor Systems)
Show Figures

Figure 1

15 pages, 8139 KiB  
Article
Application of Electric Cell-Substrate Impedance Sensing to Investigate the Cytotoxic Effects of Andrographolide on U-87 MG Glioblastoma Cell Migration and Apoptosis
by Sheng-Po Chiu, Buyandelger Batsaikhan, Huei-Mei Huang and Jia-Yi Wang
Sensors 2019, 19(10), 2275; https://doi.org/10.3390/s19102275 - 16 May 2019
Cited by 19 | Viewed by 4205
Abstract
Glioblastoma multiforme (GBM) is the most common and aggressive primary brain tumor in adults. In recent studies, the efficacy of suberoylanilide hydroxamic acid (SAHA) has been investigated for GBM. We explored the effects of two exploratory compounds, the histone deacetylase SAHA and the [...] Read more.
Glioblastoma multiforme (GBM) is the most common and aggressive primary brain tumor in adults. In recent studies, the efficacy of suberoylanilide hydroxamic acid (SAHA) has been investigated for GBM. We explored the effects of two exploratory compounds, the histone deacetylase SAHA and the natural product andrographolide, on Uppsala 87 Malignant Glioma (U-87 MG) cell migration and viability in comparison with the clinically used therapeutic agent temozolomide (TMZ). We used the electric cell–substrate impedance sensing (ECIS) system to monitor the migration of U-87 MG cells after treatment with various concentrations of these compounds. Moreover, we used the Alamar blue assay and western blotting to observe the concentration-dependent changes in the viability and apoptosis of U-87 MG cells. Our results demonstrated that both SAHA and andrographolide (10–300 μM) significantly inhibited GBM cell migration in a concentration-dependent manner, and 10 μM SAHA and 56 μM andrographolide demonstrated remarkable inhibitory effects on U-87 MG migration. Western blotting indicated that compared with TMZ, both SAHA and andrographolide induced higher expression levels of apoptosis-related proteins, such as caspase-3, BAX, and PARP in U-87 MG cells. Furthermore, all three drugs downregulated the expression of the antiapoptotic protein Bcl-2. In conclusion, SAHA and andrographolide showed exceptional results in inhibiting cell migration and motility. The ECIS wound healing assay is a powerful technique to identify and screen potential therapeutic agents that can inhibit cancer cell migration. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

17 pages, 1170 KiB  
Article
A Novel Cell-Based Hybrid Acoustic Wave Biosensor with Impedimetric Sensing Capabilities
by Fei Liu, Fang Li, Anis Nurashikin Nordin and Ioana Voiculescu
Sensors 2013, 13(3), 3039-3055; https://doi.org/10.3390/s130303039 - 4 Mar 2013
Cited by 31 | Viewed by 10057
Abstract
A novel multiparametric biosensor system based on living cells will be presented. The biosensor system includes two biosensing techniques on a single device: resonant frequency measurements and electric cell-substrate impedance sensing (ECIS). The multiparametric sensor system is based on the innovative use of [...] Read more.
A novel multiparametric biosensor system based on living cells will be presented. The biosensor system includes two biosensing techniques on a single device: resonant frequency measurements and electric cell-substrate impedance sensing (ECIS). The multiparametric sensor system is based on the innovative use of the upper electrode of a quartz crystal microbalance (QCM) resonator as working electrode for the ECIS technique. The QCM acoustic wave sensor consists of a thin AT-cut quartz substrate with two gold electrodes on opposite sides. For integration of the QCM with the ECIS technique a semicircular counter electrode was fabricated near the upper electrode on the same side of the quartz crystal. Bovine aortic endothelial live cells (BAECs) were successfully cultured on this hybrid biosensor. Finite element modeling of the bulk acoustic wave resonator using COMSOL simulations was performed. Simultaneous gravimetric and impedimetric measurements performed over a period of time on the same cell culture were conducted to validate the device’s sensitivity. The time necessary for the BAEC cells to attach and form a compact monolayer on the biosensor was 35~45 minutes for 1.5 × 104 cells/cm2 BAECs; 60 minutes for 2.0 × 104 cells/cm2 BAECs; 70 minutes for 3.0 × 104 cells/cm2 BAECs; and 100 minutes for 5.0 × 104 cells/cm2 BAECs. It was demonstrated that this time is the same for both gravimetric and impedimetric measurements. This hybrid biosensor will be employed in the future for water toxicity detection. Full article
(This article belongs to the Special Issue Last Trends in Acoustic Sensing)
Show Figures

44 pages, 3586 KiB  
Review
Microfabricated Electrochemical Cell-Based Biosensors for Analysis of Living Cells In Vitro
by Jun Wang, Chengxiong Wu, Ning Hu, Jie Zhou, Liping Du and Ping Wang
Biosensors 2012, 2(2), 127-170; https://doi.org/10.3390/bios2020127 - 25 Apr 2012
Cited by 60 | Viewed by 20465
Abstract
Cellular biochemical parameters can be used to reveal the physiological and functional information of various cells. Due to demonstrated high accuracy and non-invasiveness, electrochemical detection methods have been used for cell-based investigation. When combined with improved biosensor design and advanced measurement systems, the [...] Read more.
Cellular biochemical parameters can be used to reveal the physiological and functional information of various cells. Due to demonstrated high accuracy and non-invasiveness, electrochemical detection methods have been used for cell-based investigation. When combined with improved biosensor design and advanced measurement systems, the on-line biochemical analysis of living cells in vitro has been applied for biological mechanism study, drug screening and even environmental monitoring. In recent decades, new types of miniaturized electrochemical biosensor are emerging with the development of microfabrication technology. This review aims to give an overview of the microfabricated electrochemical cell-based biosensors, such as microelectrode arrays (MEA), the electric cell-substrate impedance sensing (ECIS) technique, and the light addressable potentiometric sensor (LAPS). The details in their working principles, measurement systems, and applications in cell monitoring are covered. Driven by the need for high throughput and multi-parameter detection proposed by biomedicine, the development trends of electrochemical cell-based biosensors are also introduced, including newly developed integrated biosensors, and the application of nanotechnology and microfluidic technology. Full article
(This article belongs to the Special Issue Electrochemical Based Biosensors)
Show Figures

Graphical abstract

Back to TopTop