Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (12,972)

Search Parameters:
Keywords = conductive heating

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 8329 KB  
Article
Washability and Electrical Performance Evaluation of Jacquard Conductive Knitted Fabrics Based on Fuzzy Comprehensive Assessment
by Su Liu, Wei Wang, Hui Yang and Jun Wu
Polymers 2026, 18(8), 934; https://doi.org/10.3390/polym18080934 - 10 Apr 2026
Abstract
This study presents a systematic evaluation of 2-layer conductive Jacquard knitted fabrics with a birdseye backing designed for wearable electronic applications. Three sets of samples with 9 different proportions of conductive yarn (27 samples) are designed on a computerized flat-knitting machine, and three [...] Read more.
This study presents a systematic evaluation of 2-layer conductive Jacquard knitted fabrics with a birdseye backing designed for wearable electronic applications. Three sets of samples with 9 different proportions of conductive yarn (27 samples) are designed on a computerized flat-knitting machine, and three indicators (conductive yarn usage ratio, resistance change ratio after washing, and temperature variation) are examined. The 2-layer Jacquard structure enables conductive yarns to form loops on both the technical face and back, thus producing continuous and interlocked conductive pathways. The experimental results show that the proportions of pattern dots for the conductive yarns determine the amount of conductive yarn used in a 2-layer Jacquard structure with the same technical parameters. For the samples with 10–90% pattern dots, the conductive yarn consumption ratio ranges from 34.80% to 65.18%. After 10 washes, resistance change ratio ranges from 27.66~55.54%, which show a moderate electrical stability. After 10 washes, the heating temperature increases by 15.6 to 19.67 °C, which show good thermal properties. Finally, a fuzzy logic evaluation is conducted with objective indicator weights. The findings provide quantitative evidence for the material–structure integration of conductive knitted textiles and support their potential for applications in next-to-skin smart garments. Full article
(This article belongs to the Section Polymer Analysis and Characterization)
20 pages, 881 KB  
Article
Characterization of Residual Woody Biomass for the Production of Densified Solid Biofuels and Their Local Utilization
by Mario Morales-Máximo, Ramiro Gudiño-Macedo, José Guadalupe Rutiaga-Quiñones, Juan Carlos Coral-Huacuz, Luis Fernando Pintor-Ibarra, Luis Bernardo López-Sosa and Víctor Manuel Ruíz-García
Fuels 2026, 7(2), 23; https://doi.org/10.3390/fuels7020023 - 10 Apr 2026
Abstract
The energy utilization of residual woody biomass is a relevant strategy for the decentralized energy transition and local waste management in rural areas. The objective of this study was to characterize (physically, chemically, and energetically) five types of residual biomass: pine branches, huinumo [...] Read more.
The energy utilization of residual woody biomass is a relevant strategy for the decentralized energy transition and local waste management in rural areas. The objective of this study was to characterize (physically, chemically, and energetically) five types of residual biomass: pine branches, huinumo (this material refers to the long, thin pine needles that, after drying and falling, form a layer on the forest floor), cherry branches and leaves, and grass waste generated in the community of San Francisco Pichátaro, Michoacán, Mexico, in order to evaluate its viability for the production of densified solid biofuels. A comprehensive analysis was conducted, including moisture content, higher heating value, proximate characterization, structural chemical analysis (using the Van Soest method), elemental CHONS analysis, ash microanalysis (by ICP-OES), and a multicriteria analysis with normalized energy and compositional indicators. The results showed that huinumo and cherry leaves were the most outstanding biomasses, presenting the highest heating values (20.7 MJ/kg) and low moisture and ash contents. Pine branches obtained the most balanced results, characterized by their equilibrium in fixed carbon and lignin, as well as their low potassium content. The multicriteria analysis showed that there is no absolute optimal biomass; however, it indicates that pine branches and huinumo are the most robust feedstocks for the production of briquettes or pellets. The results confirm the significant technical and environmental potential of local lignocellulosic residues for the production of solid biofuels and for contributing to sustainable energy solutions at the local scale. Full article
(This article belongs to the Special Issue Biofuels and Bioenergy: New Advances and Challenges)
Show Figures

Figure 1

16 pages, 5993 KB  
Article
Research on Heat Transfer Performance of Cold-Water Pipe in Ocean Thermal Energy Conversion System
by Jing Li, Bo Ning, Lele Yang, Fenlan Ou, Bo Li, Dezhi Qiu and Xuemei Jin
Processes 2026, 14(8), 1223; https://doi.org/10.3390/pr14081223 - 10 Apr 2026
Abstract
Ocean Thermal Energy Conversion (OTEC) is characterized by its abundant reserves and pollution-free nature, enabling stable power generation around the clock. Since the power output of an OTEC system is significantly influenced by the energy available from cold and warm seawater, the accurate [...] Read more.
Ocean Thermal Energy Conversion (OTEC) is characterized by its abundant reserves and pollution-free nature, enabling stable power generation around the clock. Since the power output of an OTEC system is significantly influenced by the energy available from cold and warm seawater, the accurate evaluation of the outlet temperature of the cold-water pipe (CWP) is crucial. To analyze the heat transfer performance of the CWP, this paper investigates the temperature field of the OTEC CWP and employs numerical simulation methods to conduct finite element analysis of the temperature field under different discharge conditions. The results indicate that during the pumping of deep-sea cold water through the CWP, heat is absorbed from the warmer upper seawater layers. When the pumping discharge rate is higher, the shorter fluid residence time due to higher flow velocity results in a lower outlet temperature. Compared to steel CWPs, high-density polyethylene (HDPE) is more suitable for OTEC systems due to its lower thermal conductivity and density. Full article
(This article belongs to the Section Energy Systems)
28 pages, 4769 KB  
Article
Scaled Test Program Strategy of Skin Heat Exchanger for Thermal Management in Hybrid Electric Regional Aircraft
by Benigno J. Lázaro and Ezequiel González-Martínez
Aerospace 2026, 13(4), 353; https://doi.org/10.3390/aerospace13040353 - 10 Apr 2026
Abstract
The strategy developed to carry out a scaled test program aimed at reproducing the behavior of skin heat exchangers to alleviate the heat dissipation requirements in future hybrid electric propulsion regional aircrafts is presented. The test program is intended to reproduce the dimensionless [...] Read more.
The strategy developed to carry out a scaled test program aimed at reproducing the behavior of skin heat exchangers to alleviate the heat dissipation requirements in future hybrid electric propulsion regional aircrafts is presented. The test program is intended to reproduce the dimensionless thermal response characterizing the skin heat exchanger on a predefined nominal cruise flight operation, while conducting the tests in a wind tunnel operating at low velocities and near-standard atmospheric conditions. For that purpose, dimensional analysis is used to define the geometrical scale and approach flow conditions in the wind tunnel test program, so that the dimensionless parameters describing the skin heat exchanger thermal response resemble the ones taking place under nominal flight conditions. The validation of the scaling strategy is achieved by comparing dimensionless parameters characterizing the turbulent momentum and heat transfer processes taking place at the skin heat exchanger/airflow interface surface in the flight and wind tunnel environments, by using CFD analysis based on two-equation kϵ and SST RANS turbulence modeling. The comparison reveals that the adopted wind tunnel strategy is indeed capable of closely reproducing the heat transfer process taking place in the flight environment, thus paving the way to achieve mid TLR validation of the skin heat exchanger technology. Full article
22 pages, 1540 KB  
Article
Thermal Dehydration of Hydrated Salts Under Vapor-Restricted Conditions and Its Role in Modeling Gypsum-Based Systems During Fire Exposure
by Maximilian Pache, Michaela D. Detsi, Ioannis D. Mandilaras, Dimos A. Kontogeorgos and Maria A. Founti
Fire 2026, 9(4), 159; https://doi.org/10.3390/fire9040159 - 9 Apr 2026
Abstract
Gypsum-based fire protection relies on thermally activated dehydration, where chemically bound water is released and evaporated, thereby providing an endothermic heat sink that delays heat penetration through assemblies. In parallel, inorganic hydrated salts are increasingly used as flame-retardant additives in gypsum-based systems to [...] Read more.
Gypsum-based fire protection relies on thermally activated dehydration, where chemically bound water is released and evaporated, thereby providing an endothermic heat sink that delays heat penetration through assemblies. In parallel, inorganic hydrated salts are increasingly used as flame-retardant additives in gypsum-based systems to enhance heat absorption over specific temperature ranges. Fire simulation tools and performance-based fire engineering approaches require reliable kinetic data and reaction enthalpies that can be implemented as coupled thermal–chemical source terms. However, additive-specific kinetic datasets remain limited, particularly under restricted vapor exchange conditions representative of porous construction materials. This work investigates the thermal decomposition behavior and dehydration kinetics of Aluminum Trihydrate (Al(OH)3, ATH), Magnesium Hydroxide (Mg(OH)2, MDH), Calcium Aluminate Sulfate (3CaO·Al2O3·3CaSO4·32H2O, CAS), and Magnesium Sulfate Heptahydrate (MgSO4·7H2O, ESM) with emphasis on vapor-restricted conditions representative of confined porous systems. Differential scanning calorimetry (DSC) experiments were conducted at three heating rates (2, 10, and 20 K/min for MDH, CAS and ESM and 20, 40 and 60 K/min for GB-ATH) up to 600 °C using pinhole crucibles to simulate autogenous vapor pressure. The thermal analysis indicates that ATH and MDH exhibit predominantly single-step dehydration behavior, while ESM shows a complex multi-step mechanism. Although CAS presents a single dominant thermal peak in the DSC signal, the isoconversional analysis reveals a multi-stage reaction behavior, demonstrating that peak-based interpretation alone may be insufficient for such systems. Kinetic parameters were determined using both model-free (Starink) and model-fitting approaches in accordance with the recommendations of the Kinetics Committee of the International Confederation for Thermal Analysis and Calorimetry (ICTAC). All reactions were consistently described using the Avrami–Erofeev model as an effective phenomenological representation of the conversion behavior. The extracted kinetic triplets were validated through numerical simulations, showing good agreement with experimental conversion and reaction rate data. The resulting kinetic parameters and dehydration enthalpies provide a physically consistent dataset for the description of dehydration processes under restricted vapor exchange. These results support the development of thermochemical models for gypsum-based systems; however, their transferability to full-scale assemblies remains subject to validation under coupled heat- and mass-transfer conditions. Full article
27 pages, 3030 KB  
Article
Experimental Study on the Non-Smooth Behavior of Cage-Less Ball Bearings with Localized Functional Grooves
by Jingwei Zhang, Enwen Zhou, Yibo Wang, Qiyin Lv and Yuan Zhang
Machines 2026, 14(4), 419; https://doi.org/10.3390/machines14040419 - 9 Apr 2026
Abstract
To investigate the non-smooth behaviour of cage-less ball bearings with localised functional grooves, this article first designs temperature-varying comparative experiments and rolling element discrete performance test protocols. Subsequently, it analyses the principles of heat generation, transmission, and exchange within ball bearings, establishing a [...] Read more.
To investigate the non-smooth behaviour of cage-less ball bearings with localised functional grooves, this article first designs temperature-varying comparative experiments and rolling element discrete performance test protocols. Subsequently, it analyses the principles of heat generation, transmission, and exchange within ball bearings, establishing a mathematical model for bearing thermal displacement using a dynamic model. This is followed by an analysis of rolling element discrete conditions. Finally, based on experimental results, a comparative analysis of ball bearing temperature variations under combined multi-variable loading conditions is conducted. By altering radial load, axial load, and rotational speed to measure bearing friction torque under different operating conditions, the suitability of bearing operating conditions is analysed, evaluated, and optimised. Full article
27 pages, 6134 KB  
Article
SHAP-Based Insights into Environmental and Economic Performance of a Shower Heat Exchanger Under Unbalanced Flow Conditions: A Feasibility Study
by Sabina Kordana-Obuch and Mariusz Starzec
Energies 2026, 19(8), 1845; https://doi.org/10.3390/en19081845 - 9 Apr 2026
Abstract
Heat recovery from greywater is one solution for improving the energy efficiency of buildings and reducing greenhouse gas emissions. Particular attention is paid to systems utilizing heat from shower water, which, due to its high temperature and regularity, represents a promising energy source. [...] Read more.
Heat recovery from greywater is one solution for improving the energy efficiency of buildings and reducing greenhouse gas emissions. Particular attention is paid to systems utilizing heat from shower water, which, due to its high temperature and regularity, represents a promising energy source. However, the interplay of parameters determining the financial and environmental effectiveness of such a solution has not yet been fully explored. Therefore, the aim of this paper was to identify key variables influencing the feasibility of using a shower heat exchanger operating under unbalanced flow conditions and to assess the consistency between financial and environmental effects. The analyzed net present values ranged from −€1381 to €52,168. Greenhouse gas emission reduction values ranged between 61 kgCO2e and 37,207 kgCO2e. The analysis was conducted using predictive modeling and the SHAP (SHapley Additive exPlanations) method, which allows for the interpretation of the impact of individual variables on the forecasted net present value and potential greenhouse gas emission reduction. A global analysis was carried out to determine the relative importance of variables, as well as a local analysis for selected cases. The results showed that operational variables related to shower use, particularly shower length and mixed water flow rate, significantly influenced the prediction results of both models. In the case of emission reduction, greenhouse gas emission intensity and its change over time also had a significant impact, whilst the financial effects were determined by the energy price from the perspective of the subsequent years of the system’s operation. Full article
Show Figures

Figure 1

22 pages, 16716 KB  
Article
Comparative Transcriptomic and Metabolic Analyses Reveal Temperature Intensity-Dependent Changes in Phenolic Compound Concentrations in Three Wine Grape Cultivars
by Huawei Chen, Xinyu Ren, Bowei Yang, Yang Yi, Miaomiao Wang, Ruihua Ren, Maosheng Ge and Sha Xie
Agronomy 2026, 16(8), 775; https://doi.org/10.3390/agronomy16080775 - 9 Apr 2026
Abstract
Global climate change poses a significant threat to viticulture, primarily due to high temperatures. This study examined temperature-induced changes in phenolic profiles in berries of three wine grape cultivars under 25, 35, and 45 °C for 0–48 h using HPLC-ESI-MS/MS. To investigate the [...] Read more.
Global climate change poses a significant threat to viticulture, primarily due to high temperatures. This study examined temperature-induced changes in phenolic profiles in berries of three wine grape cultivars under 25, 35, and 45 °C for 0–48 h using HPLC-ESI-MS/MS. To investigate the molecular response to severe heat stress, transcriptomic analysis was conducted in Cabernet Sauvignon berries subjected to a 45 °C treatment. Results showed that the 45 °C treatment decreased the levels of anthocyanins (particularly delphinidin-3-O-glucoside and cyanidin-3-O-glucoside) in grape berries. Acylated anthocyanins, such as malvidin-3-O-(6-acetyl)-glucoside, exhibited enhanced stability at elevated temperatures. Additionally, high temperatures increased the levels of protocatechuic and gentisic acids and decreased those of rutin, ferulic acid, and p-coumaric acid. Transcriptomic and qRT-PCR analyses revealed that the expression of OMT, LDOX, GST, F3′5′H, and 3AT was positively correlated with changes in anthocyanin levels under high temperatures, suggesting their roles in the observed phenolic alterations. These findings highlight the molecular responses of winegrapes to heat stress, providing a foundation for future viticulture strategies under changing climatic conditions. Full article
(This article belongs to the Special Issue Precision Breeding and Cultivation of Grapevine for Trait Improvement)
Show Figures

Figure 1

25 pages, 794 KB  
Article
Integrated Assessment of Solid, Liquid, and Gaseous Fuels Derived from Fixed-Bed Pyrolysis of Waste Tires
by Harryson Guimarães de Lima, Clériston Moura Vieira Júnior, Humberto Santos, Adalberto Freire do Nascimento Júnior, Antônio Celso Dantas Antonino and Sérgio Peres Ramos da Silva
Processes 2026, 14(8), 1197; https://doi.org/10.3390/pr14081197 - 9 Apr 2026
Abstract
The improper disposal of end-of-life tires poses significant environmental challenges due to their petroleum-based composition and slow degradation, while simultaneously representing an underutilized energy resource. This study investigates the slow pyrolysis of shredded waste tires in a fixed-bed electrically heated reactor to evaluate [...] Read more.
The improper disposal of end-of-life tires poses significant environmental challenges due to their petroleum-based composition and slow degradation, while simultaneously representing an underutilized energy resource. This study investigates the slow pyrolysis of shredded waste tires in a fixed-bed electrically heated reactor to evaluate the production and fuel properties of gaseous, liquid, and solid fractions. Experiments were conducted with 100 g samples under nitrogen at final temperatures of 400, 500, and 600 °C, with residence times of 40, 25, and 10 min, respectively. Higher temperatures promoted gas formation, increasing yields from 27% to 32% and achieving a maximum lower heating value of 30.54 MJ m−3 at 600 °C, with enhanced H2 and CH4 contents. Solid yields decreased slightly (41% to 37%), while char maintained stable heating values (~29 MJ kg−1). Liquid yields remained near 33% and showed high calorific values (~41 MJ kg−1), densities of 700–770 kg m−3, low acidity, low ash content, and increased viscosity at higher temperatures. Energy conversion efficiency reached 74.4% at 500 °C. The integrated evaluation of all fractions under identical conditions highlights fixed-bed pyrolysis as a promising pathway for waste-tire valorization and decentralized fuel production. Full article
(This article belongs to the Special Issue Green Metallurgical Process and Technology)
Show Figures

Figure 1

29 pages, 10810 KB  
Article
Malicious Manipulation of the Setpoint in the Temperature Control System of a Heating Process Based on Resistive Electric Heating
by Jarosław Joostberens, Aurelia Rybak, Aleksandra Rybak, Piotr Toś, Artur Kozłowski and Leszek Kasprzyczak
Electronics 2026, 15(8), 1568; https://doi.org/10.3390/electronics15081568 - 9 Apr 2026
Abstract
This article presents the potential for maliciously influencing a control system by interfering with the program code of an industrial controller, using a temperature control system for a heating process based on resistive electric heating as an example. The presented attack scenarios are [...] Read more.
This article presents the potential for maliciously influencing a control system by interfering with the program code of an industrial controller, using a temperature control system for a heating process based on resistive electric heating as an example. The presented attack scenarios are crucial for the energy efficiency of electric heating systems, which is related to the issue of cybersecurity in the area of energy security. The aim of this research was to demonstrate that a cyberattack involving the malicious manipulation of the setpoint can be carried out in a manner invisible to the heating process operator and be difficult to detect using classical time-domain control quality indicators (time-response specifications). The first involves incorporating proportional elements with mutually inverted gains into the input and output of a closed-loop system. The second method is based on adding an additional transfer function Gm(s) in parallel to the control system. The difference between the correct and manipulated setpoints is introduced into the input, and the output signal is added to the actual (hidden) value of the controlled variable. In the first method, at the moment of starting the control system, there is a difference between the apparent (falsified) value and the ambient temperature. In the second method, the inclusion of an additional Gm(s) ensures that the apparent (falsified) value of the controlled variable matches the temperature at the moment of starting the system. PID control enables achieving satisfactory control quality in heating processes, which are characterized by high inertia and time delays. Compared to classical PID regulation, advanced control methods can, under certain conditions, provide better performance in terms of quality indicators. However, due to their high computational complexity and sensitivity to model uncertainty—particularly in methods relying on accurate system identification—PID controllers continue to be widely used in industrial practice. For this reason, the present study focuses on a control system based on a PID controller as a practical solution. Based on the results, it was found that the most effective manipulation occurred within the range from 0.9 to 1.1 of the actual setpoint value for both the first and second method, using a model with Tm between 5 s and 30 s. In these cases, the quality indicators referenced to the nominal values, determined for the falsified control system responses to a step change in the setpoint, were as follows: overshoot—0.97 and 1.30 (method 1), and 0.90 and 1.10 (method 2 for 5 s), 0.75 and 1.30 (method 2 for 30 s); settling time—1.06 (method 1), and 0.98 and 1.17 (method 2 for 5 s), 0.85 and 1.14 (method 2 for 30 s). The settling times determined for the system’s response to a disturbance were: 1.00 and 1.15 (method 1), and 1.13 and 1.16 (method 2 for 5 s), 1.12 and 1.02 (method 2 for 30 s). Based on the conducted analysis, it was demonstrated that the relatively simple setpoint manipulation methods presented can effectively mask the impact of malicious interference on the temperature value in the control system of a heating process. Full article
Show Figures

Figure 1

32 pages, 3764 KB  
Article
Assessment of Compound Hydrological–Thermal Extremes over Indian River Systems
by Jaya Bharat Reddy Buchupalle, Satish Kumar Mummidivarapu, Shaik Rehana, Shahid Latif and Taha B. M. J. Ouarda
Water 2026, 18(8), 896; https://doi.org/10.3390/w18080896 - 9 Apr 2026
Abstract
River water quality assessment has traditionally been conducted using univariate or threshold-based approaches; however, the exploration of extremes assessment under bivariate water quality variables has been limited by many studies. Understanding the compound extremes of low river discharge (Q) and elevated river water [...] Read more.
River water quality assessment has traditionally been conducted using univariate or threshold-based approaches; however, the exploration of extremes assessment under bivariate water quality variables has been limited by many studies. Understanding the compound extremes of low river discharge (Q) and elevated river water temperatures (RWTs) resulting from climatic variability is essential for effective water quality management and protection of the river. This study investigates the joint behaviour of RWTs and Q in six Indian rivers: Kaveri, Mahi, Sabarmati, Vardha, Bhadra, and Yamuna. The Weibull-3P and Generalised Extreme Value (GEV-3P) distributions best fit for Q and RWTs, respectively. The adequacy of eighteen different parametric copula classes was evaluated. The Gaussian copula provided the best fit for the Vardha River, the Frank copula for Bhadra, and the BB8 copula for the Yamuna River. The evaluation of joint return periods (RPs) and conditional distributions has identified notable spatial variability in compound hydrological and thermal extreme hazards. The semi-arid Vardha River showed the shortest RPs for simultaneous low Q and high RWTs, indicating a greater likelihood of combined extremes. Conversely, the monsoon-fed Bhadra River displayed moderate hazard levels, while the Himalayan-fed Yamuna River had the longest joint RPs and the lowest conditional probabilities. This suggests that simultaneous extreme drought and heat events are less likely in the Yamuna basin, although significant risks remain for less severe thresholds. Full article
Show Figures

Figure 1

20 pages, 5159 KB  
Article
Genome-Wide Analysis of the Hsf Family and Functional Characterization of CiHsf10 Under Low-Temperature Stress in Chrysanthemum indicum
by Yuzhi Song, Siyu Feng, Xuanlu Liu, Jiayi Yin, Qianru Yu, Lixi Qu, Xue Yang, Yun Bai and Yunwei Zhou
Plants 2026, 15(8), 1149; https://doi.org/10.3390/plants15081149 - 9 Apr 2026
Abstract
To improve Chrysanthemum tolerance to low temperatures and its adaptability to low autumn temperatures in Northeast China, we conducted the first genome-wide identification of the heat shock transcription factors (Hsfs) in Chrysanthemum indicum under low-temperature stress. Based on genome-wide analyses, we identified 14 [...] Read more.
To improve Chrysanthemum tolerance to low temperatures and its adaptability to low autumn temperatures in Northeast China, we conducted the first genome-wide identification of the heat shock transcription factors (Hsfs) in Chrysanthemum indicum under low-temperature stress. Based on genome-wide analyses, we identified 14 CiHsf genes in Chrysanthemum indicum. Based on structural characteristics, the genes were grouped into two subfamilies, comprising 10 HsfA and four HsfB members, with no representatives of the HsfC subfamily detected. CiHsf1~CiHsf14 were located on seven chromosomes, and their promoter regions harbored numerous cis-acting elements associated with responses to low temperature, hormones, and light. Tissue-specific expression profiling revealed that seven CiHsf genes were predominantly expressed in roots, two in stems, three in leaves, and two in flowers. The analysis of low-temperature expression characteristics showed that CiHsf2, CiHsf5, CiHsf8, and CiHsf10 were significantly upregulated following cold acclimation, indicating that these genes may participate in the low-temperature response mechanism of Chrysanthemum indicum. Here, we demonstrated that transient transformation of Chrysanthemum indicum with 35S:CiHsf10 reduced reactive oxygen species (ROS) accumulation under low-temperature stress, which may contribute to enhanced cold tolerance. Full article
(This article belongs to the Section Plant Genetics, Genomics and Biotechnology)
Show Figures

Figure 1

29 pages, 3165 KB  
Review
Thermal and Dynamic Behavior of Anaerobic Digesters Under Neotropical Conditions: A Review
by Ricardo Rios, Nacari Marin-Calvo and Euclides Deago
Energies 2026, 19(8), 1838; https://doi.org/10.3390/en19081838 - 8 Apr 2026
Abstract
Anaerobic digesters operating under neotropical conditions face significant technological constraints. High humidity, intense solar radiation, and pronounced diurnal temperature variations increase conductive, convective, and radiative heat losses. These factors reduce internal thermal stability and directly affect methane production rates and overall energy efficiency. [...] Read more.
Anaerobic digesters operating under neotropical conditions face significant technological constraints. High humidity, intense solar radiation, and pronounced diurnal temperature variations increase conductive, convective, and radiative heat losses. These factors reduce internal thermal stability and directly affect methane production rates and overall energy efficiency. As a result, thermal instability becomes a recurrent operational bottleneck in biogas plants without active temperature control. This review examines the thermal and dynamic behavior of anaerobic reactors from a process-engineering perspective. It integrates energy balances, heat-transfer mechanisms, and computational fluid dynamics (CFD) modeling. The combined effects of temperature gradients, hydrodynamic mixing patterns, and structural material properties are analyzed to determine their influence on thermal homogeneity, microbial stability, and methane yield consistency under mesophilic conditions. Technological strategies to mitigate thermal losses are evaluated. These include passive insulation using low-conductivity materials, geometry optimization supported by numerical modeling, and thermal recirculation schemes, as these factors govern temperature distribution and process resilience. Current limitations are also discussed, particularly the frequent decoupling between ADM1-based kinetic models and transient heat-transfer analysis. This separation restricts predictive capability under real-scale diurnal temperature oscillations. The development and validation of coupled hydrodynamic–thermal–biokinetic models under fluctuating neotropical boundary conditions are proposed as critical steps. Such integrated approaches can enhance operational stability, ensure consistent methane production, and improve energy self-sufficiency in organic waste valorization systems. Full article
Show Figures

Figure 1

26 pages, 3491 KB  
Article
Alternative Energy Source Integration in Medium-Capacity Gas Boiler Plant in Latvian Climate Conditions: Case Study for 6.38 MW Plant Servicing a Residential District
by Jānis Jākobsons, Filips Kukšinovs, Kristina Ļebedeva, Aleksandrs Zajacs and Jeļena Tihana
Energies 2026, 19(8), 1836; https://doi.org/10.3390/en19081836 - 8 Apr 2026
Abstract
One of the main goals of heat and electricity producers in Latvia is to reduce the use of fossil fuels and introduce alternative fuel types that could help in reducing carbon dioxide emissions. This work focuses on addressing the set issue for a [...] Read more.
One of the main goals of heat and electricity producers in Latvia is to reduce the use of fossil fuels and introduce alternative fuel types that could help in reducing carbon dioxide emissions. This work focuses on addressing the set issue for a medium-capacity automated gas boiler plant, which provides heat for a local residential district. The following solutions were selected for boiler plant optimization: an electric boiler, a heat storage system, and solar collectors. Operating mode simulations were conducted for the electric boiler and solar collectors using Excel and Polysun (Standard) software. Simulations were created based on energy resource demand data obtained from a residential district located in Latvia and local energy resource prices/heat energy tariffs for the year 2024. The results from the simulations were used for technical and economic calculations to determine the payback period of the project. The electric boiler, together with the thermal energy storage tank and solar collectors, can produce 5903.04 MWh/year (~70% of local district heat demand) of thermal energy. This reduces the CO2 emissions of the boiler plant by at least 1186.51 tCO2 per year, which, at an emission quota price of 63.80 EUR/tCO2, allows for savings of 75,699.34 EUR per year (12.82 EUR/MWh heat energy). The project’s discounted payback period is 4.12 years, considering the reduction in the cost of the CO2 emission quota. The results of this study show that the chosen technologies are straightforward solutions that can be used to optimize existing boiler plants with limited space and can provide financial benefits to heat energy producers. Full article
Show Figures

Figure 1

21 pages, 4499 KB  
Article
Genetic Model and Main Controlling Factors of the Wuding Geothermal Field, Yunnan Province, China: Implications for Sustainable Geothermal Utilization
by Junjie Ba, Fufang Gao and Qingyu Zhang
Sustainability 2026, 18(8), 3681; https://doi.org/10.3390/su18083681 - 8 Apr 2026
Abstract
Located in the north of Yunnan Province, China, the Wuding geothermal area is a typical medium- and low-temperature geothermal system with strong hydrothermal activity and development potential as a clean and renewable energy resource. This study systematically investigates the main controlling factors of [...] Read more.
Located in the north of Yunnan Province, China, the Wuding geothermal area is a typical medium- and low-temperature geothermal system with strong hydrothermal activity and development potential as a clean and renewable energy resource. This study systematically investigates the main controlling factors of the Wuding geothermal field through field investigation, hydrochemical analysis, and stable isotope analysis, and puts forward a genetic model of the geothermal field. The results show that the Wuding geothermal field is a medium- to low-temperature, conduction-dominated geothermal system, and its geothermal water is predominantly of the Ca–HCO3 (calcium bicarbonate) type. The recharge area lies at an altitude above 2250 m, which is speculated to be within the mountainous area in the southwest of the study area. The underground hot water in the area is immature water. The source water circulates to the deep heat storage zone along faults, rises to the surface through heat convection, and is exposed as hot springs. Upon discharge, the geothermal water mixes with shallow cold water, with cold-water dilution accounting for up to 85% of the total volume. Using the silica thermometer, cation thermometer, and silicon enthalpy model, the maximum temperature of heat storage is estimated to be 91 °C, with the depth of geothermal water circulation reaching 2200 m. The thermal reservoir is composed of dolomites of the Upper Cambrian Erdaoshui Formation (∈3e) and Sinian Dengying Formation (Zbd). Its heat source is heat flow from the upper mantle and the decay of radioactive elements. Continuous heat flow to the thermal reservoir is maintained through the fold fracture zone and faults in the core of the Hongshanwan anticline. The proposed genetic model of the Wuding geothermal field provides a scientific basis for the sustainable redevelopment and utilization of this geothermal resource and is of significance for regional low-carbon energy use and socio-economic sustainable development. Full article
Show Figures

Figure 1

Back to TopTop