Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (46)

Search Parameters:
Keywords = compton imaging

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 4958 KB  
Article
Compton Camera X-Ray Fluorescence Imaging Design and Image Reconstruction Algorithm Optimization
by Shunmei Lu, Kexin Peng, Peng Feng, Cheng Lin, Qingqing Geng and Junrui Zhang
J. Imaging 2025, 11(9), 300; https://doi.org/10.3390/jimaging11090300 - 3 Sep 2025
Viewed by 770
Abstract
Traditional X-ray fluorescence computed tomography (XFCT) suffers from issues such as low photon collection efficiency, slow data acquisition, severe noise interference, and poor imaging quality due to the limitations of mechanical collimation. This study proposes to design an X-ray fluorescence imaging system based [...] Read more.
Traditional X-ray fluorescence computed tomography (XFCT) suffers from issues such as low photon collection efficiency, slow data acquisition, severe noise interference, and poor imaging quality due to the limitations of mechanical collimation. This study proposes to design an X-ray fluorescence imaging system based on bilateral Compton cameras and to develop an optimized reconstruction algorithm to achieve high-quality 2D/3D imaging of low-concentration samples (0.2% gold nanoparticles). A system equipped with bilateral Compton cameras was designed, replacing mechanical collimation with “electronic collimation”. The traditional LM-MLEM algorithm was optimized through improvements in data preprocessing, system matrix construction, iterative processes, and post-processing, integrating methods such as Total Variation (TV) regularization (anisotropic TV included), filtering, wavelet-domain constraints, and isosurface rendering. Successful 2D and 3D reconstruction of 0.2% gold nanoparticles was achieved. Compared with traditional algorithms, improvements were observed in convergence, stability, speed, quality, and accuracy. The system exhibited high detection efficiency, angular resolution, and energy resolution. The Compton camera-based XFCT overcomes the limitations of traditional methods; the optimized algorithm enables low-noise imaging at ultra-low concentrations and has potential applications in early cancer diagnosis and material analysis. Full article
(This article belongs to the Section Image and Video Processing)
Show Figures

Figure 1

14 pages, 2276 KB  
Article
X-Ray Interaction and the Electronic, Atomic Cross-Sections and Compton Mass-Attenuation Coefficients of Human Blood, Breasts, Eye Lens, Ovaries, and Testis
by Daniel Banks, Elise Kapshtica, Jia Ali, Sami Raja, Madhesh Raja, Mishka Ali and Muhammad Maqbool
Radiation 2025, 5(3), 24; https://doi.org/10.3390/radiation5030024 - 31 Aug 2025
Viewed by 968
Abstract
The Klein–Nishina formula is used to calculate and investigate the electronic cross-section, atomic cross-section, and Compton mass attenuation coefficients for the human blood, breasts, eye lens, ovaries, and testis, using X-rays in the 0.1–20 MeV energy range. The effects of radiation energy, tissue [...] Read more.
The Klein–Nishina formula is used to calculate and investigate the electronic cross-section, atomic cross-section, and Compton mass attenuation coefficients for the human blood, breasts, eye lens, ovaries, and testis, using X-rays in the 0.1–20 MeV energy range. The effects of radiation energy, tissue effective charge number, tissue density, and tissue electronic density on these parameters were studied. The results show that the electronic cross-section and atomic cross-section decrease with increasing radiation energy. These parameters are found to be linearly increasing when the density and electron density of a tissue increase. This increase is more rapid with a bigger slope when the electron density increases as compared to the density of each tissue. A complex relationship between these coefficients and the effective charge number Zeff of tissues is observed because Zeff changes with the energy and linear attenuation coefficient of a tissue. The Compton mass attenuation coefficient is found to be dependent on the effective charge number to mass number ratio Zeff/Aeff instead of just the effective charge number. This increase in the Compton mass attenuation coefficient with increasing Zeff/Aeff is rapid for the lower values of Zeff/Aeff. However, for a higher Zeff/Aeff ratio, the increase is very slow and becomes almost constant for X-ray energies above 10 MeV. The calculated parameters are useful in determining radiation dose for the investigated tissues and their response to low and high-energy X-rays. The results and outcomes are also very useful in shielding and protecting tissues from the hazards of radiation. These parameters are also helpful in determining the scattered and optimum doses to improve image quality and treatment options in radiology and radiation therapy to offer the best care. Full article
Show Figures

Figure 1

13 pages, 2940 KB  
Article
Research on Wavelength-Shifting Fiber Scintillator for Detecting Low-Intensity X-Ray Backscattered Photons
by Baolu Yang, Zhe Yang, Xin Wang, Baozhong Mu, Jie Xu, Cheng Yang and Hong Li
Photonics 2025, 12(6), 567; https://doi.org/10.3390/photonics12060567 - 4 Jun 2025
Cited by 1 | Viewed by 792
Abstract
High-sensitivity fiber scintillator detectors are the key to achieving high signal-to-noise ratio and high contrast imaging in X-ray Compton backscattering technology. We established a simulation model of wavelength-shifting fiber (WSF) scintillator detectors based on Geant4. The influences of ray source energy, detection area, [...] Read more.
High-sensitivity fiber scintillator detectors are the key to achieving high signal-to-noise ratio and high contrast imaging in X-ray Compton backscattering technology. We established a simulation model of wavelength-shifting fiber (WSF) scintillator detectors based on Geant4. The influences of ray source energy, detection area, number of WSFs, and coupling mechanism on detection efficiency were simulated. By using the epoxy resin coupling method, the transmission efficiency between the WSF and scintillator was increased from 4.56% to 19.79%. Based on the simulation data, we developed an X-ray WSFs scintillator detector, built an X-ray backscattering imaging experimental system, obtained high-contrast backscattering images, and verified the performance of the detector. Full article
(This article belongs to the Special Issue Optical Technologies for Measurement and Metrology)
Show Figures

Figure 1

18 pages, 4377 KB  
Article
Deep Convolutional Framelets for Dose Reconstruction in Boron Neutron Capture Therapy with Compton Camera Detector
by Angelo Didonna, Dayron Ramos Lopez, Giuseppe Iaselli, Nicola Amoroso, Nicola Ferrara and Gabriella Maria Incoronata Pugliese
Cancers 2025, 17(1), 130; https://doi.org/10.3390/cancers17010130 - 3 Jan 2025
Cited by 1 | Viewed by 1498
Abstract
Background: Boron neutron capture therapy (BNCT) is an innovative binary form of radiation therapy with high selectivity towards cancer tissue based on the neutron capture reaction 10B(n,α)7Li, consisting in the exposition of patients to neutron beams after administration [...] Read more.
Background: Boron neutron capture therapy (BNCT) is an innovative binary form of radiation therapy with high selectivity towards cancer tissue based on the neutron capture reaction 10B(n,α)7Li, consisting in the exposition of patients to neutron beams after administration of a boron compound with preferential accumulation in cancer cells. The high linear energy transfer products of the ensuing reaction deposit their energy at the cell level, sparing normal tissue. Although progress in accelerator-based BNCT has led to renewed interest in this cancer treatment modality, in vivo dose monitoring during treatment still remains not feasible and several approaches are under investigation. While Compton imaging presents various advantages over other imaging methods, it typically requires long reconstruction times, comparable with BNCT treatment duration. Methods: This study aims to develop deep neural network models to estimate the dose distribution by using a simulated dataset of BNCT Compton camera images. The models pursue the avoidance of the iteration time associated with the maximum-likelihood expectation-maximization algorithm (MLEM), enabling a prompt dose reconstruction during the treatment. The U-Net architecture and two variants based on the deep convolutional framelets framework have been used for noise and artifact reduction in few-iteration reconstructed images. Results: This approach has led to promising results in terms of reconstruction accuracy and processing time, with a reduction by a factor of about 6 with respect to classical iterative algorithms. Conclusions: This can be considered a good reconstruction time performance, considering typical BNCT treatment times. Further enhancements may be achieved by optimizing the reconstruction of input images with different deep learning techniques. Full article
(This article belongs to the Section Methods and Technologies Development)
Show Figures

Figure 1

17 pages, 23301 KB  
Article
A 3D Dual-Particle Imaging Algorithm for Multiple Imagers
by Dhruv Garg, Ricardo Lopez, Oskari Pakari, Shaun D. Clarke and Sara A. Pozzi
J. Nucl. Eng. 2024, 5(4), 584-600; https://doi.org/10.3390/jne5040036 - 20 Dec 2024
Cited by 1 | Viewed by 1483
Abstract
The ability to localize and image radiation sources has found use in various applications for nuclear nonproliferation practices, specifically in treaty verification, nuclear safeguards, and homeland security. Technologies that are capable of angular radiation imaging have been prevalent for years and, recently, 3D [...] Read more.
The ability to localize and image radiation sources has found use in various applications for nuclear nonproliferation practices, specifically in treaty verification, nuclear safeguards, and homeland security. Technologies that are capable of angular radiation imaging have been prevalent for years and, recently, 3D imaging technologies making use of emerging media like mixed reality have been rapidly developing and gaining popularity. Modern imaging techniques typically use a Compton camera to record coincident events and reconstruct the incident directional information of a gamma ray-emitting radiation source. However, Compton cameras are limited as they cannot obtain accurate source depth information when used for simple back projection imaging. Neutron scatter cameras are a complementary imaging technique that use double elastic scatters but also have their own limitations. This work presents a framework for multiple scatter-based particle imagers to construct 3D images and to localize a radiation source using gamma rays or fast neutrons. Specifically, localization is achieved by accounting for the position of the imagers. The imaging algorithm was validated using experimental data, measuring a 252Cf source. A three-dimensional representation of the imaging data provides a more intuitive and informative depiction of source positions and can aid in scenarios with complex environmental geometries such as when sources are in containers. Full article
Show Figures

Figure 1

15 pages, 17109 KB  
Article
Investigations on the Performance of a 5 mm CdTe Timepix3 Detector for Compton Imaging Applications
by Juan S. Useche Parra, Gerardo Roque, Michael K. Schütz, Michael Fiederle and Simon Procz
Sensors 2024, 24(24), 7974; https://doi.org/10.3390/s24247974 - 13 Dec 2024
Cited by 1 | Viewed by 1612
Abstract
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes [...] Read more.
Nuclear power plant decommissioning requires the rapid and accurate classification of radioactive waste in narrow spaces and under time constraints. Photon-counting detector technology offers an effective solution for the quick classification and detection of radioactive hotspots in a decommissioning environment. This paper characterizes a 5 mm CdTe Timepix3 detector and evaluates its feasibility as a single-layer Compton camera. The sensor’s electron mobility–lifetime product and resistivity are studied across bias voltages ranging from −100 V to −3000 V, obtaining values of μeτe = (1.2 ± 0.1) × 10−3 cm2V−1, and two linear regions with resistivities of ρI=(5.8±0.2) GΩ cm and ρII=(4.1±0.1) GΩ cm. Additionally, two calibration methodologies are assessed to determine the most suitable for Compton applications, achieving an energy resolution of 16.3 keV for the 137Cs photopeak. The electron’s drift time in the sensor is estimated to be (122.3 ± 7.4) ns using cosmic muons. Finally, a Compton reconstruction of two simultaneous point-like sources is performed, demonstrating the detector’s capability to accurately locate radiation hotspots with a ∼51 cm resolution. Full article
(This article belongs to the Special Issue Recent Advances in X-Ray Sensing and Imaging)
Show Figures

Figure 1

12 pages, 6014 KB  
Article
Scintillation in Liquid Xenon for Gamma-Ray Medical Imaging: From Single Time-over-Threshold to Multi-Time-over-Threshold PMT Signal Measurements
by Quentin Lainé, Nicolas Beaupere, Dingbang Cai, Eric Morteau, Fabrice Seguin, Dominique Thers and Cyril Lahuec
Sensors 2024, 24(17), 5826; https://doi.org/10.3390/s24175826 - 8 Sep 2024
Viewed by 1486
Abstract
In this paper, a new light event acquisition chain in a three-gamma liquid xenon prototype for medical nuclear imaging is presented. The prototype implements the Multi-Time-Over-Threshold (MTOT) method. This method surpasses the Single-Time-Over-Threshold (STOT) by precisely determining both the number of vacuum ultraviolet [...] Read more.
In this paper, a new light event acquisition chain in a three-gamma liquid xenon prototype for medical nuclear imaging is presented. The prototype implements the Multi-Time-Over-Threshold (MTOT) method. This method surpasses the Single-Time-Over-Threshold (STOT) by precisely determining both the number of vacuum ultraviolet (VUV) photons detected by each photomultiplier tube (PMT) and their arrival times for light signal measurement. Based on both the experimental and simulated results, the MTOT method achieved a 70% improvement in reconstructing photoelectrons (PEs) and enhanced the precision of the arrival time estimation by 20–30% compared with STOT. These results will enable an upgrade of the XEMIS2 (Xenon Medical Imaging System) camera, improving its performance as the imaged activity increases. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

16 pages, 1306 KB  
Review
Investigating the Properties of the Relativistic Jet and Hot Corona in AGN with X-ray Polarimetry
by Dawoon E. Kim, Laura Di Gesu, Frédéric Marin, Alan P. Marscher, Giorgio Matt, Paolo Soffitta, Francesco Tombesi, Enrico Costa and Immacolata Donnarumma
Galaxies 2024, 12(3), 20; https://doi.org/10.3390/galaxies12030020 - 23 Apr 2024
Cited by 5 | Viewed by 2344
Abstract
X-ray polarimetry has been suggested as a prominent tool for investigating the geometrical and physical properties of the emissions from active galactic nuclei (AGN). The successful launch of the Imaging X-ray Polarimetry Explorer (IXPE) on 9 December 2021 has expanded the previously restricted [...] Read more.
X-ray polarimetry has been suggested as a prominent tool for investigating the geometrical and physical properties of the emissions from active galactic nuclei (AGN). The successful launch of the Imaging X-ray Polarimetry Explorer (IXPE) on 9 December 2021 has expanded the previously restricted scope of polarimetry into the X-ray domain, enabling X-ray polarimetric studies of AGN. Over a span of two years, IXPE has observed various AGN populations, including blazars and radio-quiet AGN. In this paper, we summarize the remarkable discoveries achieved thanks to the opening of the new window of X-ray polarimetry of AGN through IXPE observations. We will delve into two primary areas of interest: first, the magnetic field geometry and particle acceleration mechanisms in the jets of radio-loud AGN, such as blazars, where the relativistic acceleration process dominates the spectral energy distribution; and second, the geometry of the hot corona in radio-quiet AGN. Thus far, the IXPE results from blazars favor the energy-stratified shock acceleration model, and they provide evidence of helical magnetic fields inside the jet. Concerning the corona geometry, the IXPE results are consistent with a disk-originated slab-like or wedge-like shape, as could result from Comptonization around the accretion disk. Full article
(This article belongs to the Special Issue Multi-Phase Fueling and Feedback Processes in Jetted AGN)
Show Figures

Figure 1

15 pages, 1222 KB  
Review
Scattering Polarimetry in the Hard X-ray Range
by Enrico Costa
Instruments 2024, 8(1), 20; https://doi.org/10.3390/instruments8010020 - 2 Mar 2024
Cited by 1 | Viewed by 2156
Abstract
In one and a half years, the Imaging X-ray Polarimetry Explorer has demonstrated the role and the potentiality of Polarimetry in X-ray Astronomy. The next steps include extension to higher energies. There is margin for an extension of the photoelectric approach up to [...] Read more.
In one and a half years, the Imaging X-ray Polarimetry Explorer has demonstrated the role and the potentiality of Polarimetry in X-ray Astronomy. The next steps include extension to higher energies. There is margin for an extension of the photoelectric approach up to 20–25 keV, but above that energy the only technique is Compton Scattering. Grazing incidence optics can focus photons up to 80 keV, not excluding a marginal extension to 150–200 keV. Given the physical constraints involved, the passage from photoelectric to scattering approach can make less effective the use of optics because of the high background. I discuss the choices in terms of detector design to mitigate the problem and the guidelines for future technological developments. Full article
Show Figures

Figure 1

8 pages, 465 KB  
Proceeding Paper
An Iterative Bayesian Algorithm for 3D Image Reconstruction Using Multi-View Compton Data
by Nhan Le, Hichem Snoussi and Alain Iltis
Phys. Sci. Forum 2023, 9(1), 2; https://doi.org/10.3390/psf2023009002 - 24 Nov 2023
Cited by 1 | Viewed by 1361
Abstract
Conventional maximum likelihood-based algorithms for 3D Compton image reconstruction are often stuck with slow convergence and large data volume, which could be unsuitable for some practical applications, such as nuclear engineering. Taking advantage of the Bayesian framework, we propose a fast-converging iterative maximum [...] Read more.
Conventional maximum likelihood-based algorithms for 3D Compton image reconstruction are often stuck with slow convergence and large data volume, which could be unsuitable for some practical applications, such as nuclear engineering. Taking advantage of the Bayesian framework, we propose a fast-converging iterative maximum a posteriori reconstruction algorithm under the assumption of the Poisson data model and Markov random field-based convex prior in this paper. The main originality resides in developing a new iterative maximization scheme with simultaneous updates following the line search strategy to bypass the spatial dependencies among neighboring voxels. Numerical experiments on real datasets conducted with hand-held Temporal Compton cameras developed by Damavan Imaging company and punctual 0.2 MBq 22Na sources with zero-mean Gaussian Markov random field confirm the outperformance of the proposed maximum a posteriori algorithm over various existing expectation–maximization type solutions. Full article
Show Figures

Figure 1

19 pages, 8642 KB  
Article
A Portable Three-Layer Compton Camera for Wide-Energy-Range Gamma-ray Imaging: Design, Simulation and Preliminary Testing
by Jipeng Zhang, Xiong Xiao, Ye Chen, Bin Zhang, Xinhua Ma, Xianyun Ai and Jinglun Li
Sensors 2023, 23(21), 8951; https://doi.org/10.3390/s23218951 - 3 Nov 2023
Cited by 3 | Viewed by 2554
Abstract
(1) Background: The imaging energy range of a typical Compton camera is limited due to the fact that scattered gamma photons are seldom fully absorbed when the incident energies are above 3 MeV. Further improving the upper energy limit of gamma-ray imaging has [...] Read more.
(1) Background: The imaging energy range of a typical Compton camera is limited due to the fact that scattered gamma photons are seldom fully absorbed when the incident energies are above 3 MeV. Further improving the upper energy limit of gamma-ray imaging has important application significance in the active interrogation of special nuclear materials and chemical warfare agents, as well as range verification of proton therapy. (2) Methods: To realize gamma-ray imaging in a wide energy range of 0.3~7 MeV, a principle prototype, named a portable three-layer Compton camera, is developed using the scintillation detector that consists of an silicon photomultiplier array coupled with a Gd3Al2Ga3O12:Ce pixelated scintillator array. Implemented in a list-mode maximum likelihood expectation maximization algorithm, a far-field energy-domain imaging method based on the two interaction events is applied to estimate the initial energy and spatial distribution of gamma-ray sources. The simulation model of the detectors is established based on the Monte Carlo simulation toolkit Geant4. The reconstructed images of a 133Ba, a 137Cs and a 60Co point-like sources have been successfully obtained with our prototype in laboratory tests and compared with simulation studies. (3) Results: The proportion of effective imaging events accounts for about 2%, which allows our prototype to realize the reconstruction of the distribution of a 0.05 μSv/h 137Cs source in 10 s. The angular resolution for resolving two 137Cs point-like sources is 15°. Additional simulated imaging of the 6.13 MeV gamma-rays from 14.1 MeV neutron scattering with water preliminarily demonstrates the imaging capability for high incident energy. (4) Conclusions: We conclude that the prototype has a good imaging performance in a wide energy range (0.3~7 MeV), which shows potential in several MeV gamma-ray imaging applications. Full article
Show Figures

Figure 1

11 pages, 6887 KB  
Article
Imaging Liquid Water in a Polymer Electrolyte Fuel Cell with High-Energy X-ray Compton Scattering
by Tetsuya Miyazawa, Naruki Tsuji, Daiki Fujioka, Takuma Kaneko, Yuki Mizuno, Yoshiharu Uchimoto, Hideto Imai and Yoshiharu Sakurai
Appl. Sci. 2023, 13(19), 10753; https://doi.org/10.3390/app131910753 - 27 Sep 2023
Cited by 4 | Viewed by 2192
Abstract
Compton scattering imaging with intense, high-energy synchrotron X-rays allows us to visualize a light element substance in an operating electrochemical device. In this paper, we report the first experiment of Compton scattering imaging (CSI) on an operating polymer electrolyte fuel cell (PEFC). The [...] Read more.
Compton scattering imaging with intense, high-energy synchrotron X-rays allows us to visualize a light element substance in an operating electrochemical device. In this paper, we report the first experiment of Compton scattering imaging (CSI) on an operating polymer electrolyte fuel cell (PEFC). The novelty of the CSI technique is a non-destructive direct observation of cross-sectional images with a sensitivity to light elements and a capability of simultaneous measurements with fluorescent X-rays of heavy elements. Analyses of the observed images provide the cross-sectional distribution of generated liquid water and its current density dependency. The results show that the amount of generated water increases in the vicinity of the cathode catalyst layer at current densities ranging from 100 to 500 mA/cm2, while it remains constant or slightly decreases from 500 to 900 mA/cm2. In both the gas diffusion layer and the channel, liquid water is observed near the channel and rib interface above 500 mA/cm2, indicating the formation of a liquid water flow path. In addition, simultaneous measurements of fluorescent Pt-Ka X-rays reveal a significant correlation between the generated liquid water and Pt catalysts, using the Pearson correlation coefficient. The result shows that water is dispersed in the catalyst layer without any correlation with the amount of Pt catalysts at low current densities, but water tends to be distributed in the Pt-rich areas at high current densities. This study demonstrates that Compton scattering imaging is one of the unique techniques to characterize the behavior of generated liquid water in an operating PEFC. Full article
(This article belongs to the Special Issue Advanced Technologies in Hydrogen Fuel Cell)
Show Figures

Figure 1

12 pages, 1558 KB  
Article
Study of Alternative Imaging Methods for In Vivo Boron Neutron Capture Therapy
by Dayron Ramos López, Gabriella Maria Incoronata Pugliese, Giuseppe Iaselli, Nicola Amoroso, Chunhui Gong, Valeria Pascali, Saverio Altieri and Nicoletta Protti
Cancers 2023, 15(14), 3582; https://doi.org/10.3390/cancers15143582 - 12 Jul 2023
Cited by 3 | Viewed by 2230
Abstract
Boron Neutron Capture Therapy (BNCT) is an innovative and highly selective treatment against cancer. Nowadays, in vivo boron dosimetry is an important method to carry out such therapy in clinical environments. In this work, different imaging methods were tested for dosimetry and tumor [...] Read more.
Boron Neutron Capture Therapy (BNCT) is an innovative and highly selective treatment against cancer. Nowadays, in vivo boron dosimetry is an important method to carry out such therapy in clinical environments. In this work, different imaging methods were tested for dosimetry and tumor monitoring in BNCT based on a Compton camera detector. A dedicated dataset was generated through Monte Carlo tools to study the imaging capabilities. We first applied the Maximum Likelihood Expectation Maximization (MLEM) iterative method to study dosimetry tomography. As well, two methods based on morphological filtering and deep learning techniques with Convolutional Neural Networks (CNN), respectively, were studied for tumor monitoring. Furthermore, clinical aspects such as the dependence on the boron concentration ratio in image reconstruction and the stretching effect along the detector position axis were analyzed. A simulated spherical gamma source was studied in several conditions (different detector distances and boron concentration ratios) using MLEM. This approach proved the possibility of monitoring the boron dose. Tumor monitoring using the CNN method shows promising results that could be enhanced by increasing the training dataset. Full article
(This article belongs to the Special Issue Boron Neutron Capture Therapy: Challenges, Past, Present and Future)
Show Figures

Figure 1

10 pages, 584 KB  
Review
Review of Development and Recent Advances in Biomedical X-ray Fluorescence Imaging
by Theresa Staufer and Florian Grüner
Int. J. Mol. Sci. 2023, 24(13), 10990; https://doi.org/10.3390/ijms241310990 - 1 Jul 2023
Cited by 20 | Viewed by 5460
Abstract
The use of X-rays for non-invasive imaging has a long history, which has resulted in several well-established methods in preclinical as well as clinical applications, such as tomographic imaging or computed tomography. While projection radiography provides anatomical information, X-ray fluorescence analysis allows quantitative [...] Read more.
The use of X-rays for non-invasive imaging has a long history, which has resulted in several well-established methods in preclinical as well as clinical applications, such as tomographic imaging or computed tomography. While projection radiography provides anatomical information, X-ray fluorescence analysis allows quantitative mapping of different elements in samples of interest. Typical applications so far comprise the identification and quantification of different elements and are mostly located in material sciences, archeology and environmental sciences, whereas the use of the technique in life sciences has been strongly limited by intrinsic spectral background issues arising in larger objects, so far. This background arises from multiple Compton-scattering events in the objects of interest and strongly limits the achievable minimum detectable marker concentrations. Here, we review the history and report on the recent promising developments of X-ray fluorescence imaging (XFI) in preclinical applications, and provide an outlook on the clinical translation of the technique, which can be realized by reducing the above-mentioned intrinsic background with dedicated algorithms and by novel X-ray sources. Full article
(This article belongs to the Special Issue X-ray Spectroscopy in Life Sciences)
Show Figures

Figure 1

18 pages, 12534 KB  
Article
Revealing the Materials, Painting Techniques, and State of Preservation of a Heavily Altered Early 19th Century Greek Icon through MA-XRF
by Georgios P. Mastrotheodoros, Anastasios Asvestas, Theofanis Gerodimos and Dimitrios F. Anagnostopoulos
Heritage 2023, 6(2), 1903-1920; https://doi.org/10.3390/heritage6020102 - 13 Feb 2023
Cited by 11 | Viewed by 4846
Abstract
Macroscopic X-ray fluorescence analysis (MA-XRF) is a non-destructive analytical technique that allows for the rapid and thorough investigation of paintings; therefore, it is nowadays increasingly involved in relevant studies. In the present work, a state-of-the-art MA-XRF set-up is utilized to identify the painting [...] Read more.
Macroscopic X-ray fluorescence analysis (MA-XRF) is a non-destructive analytical technique that allows for the rapid and thorough investigation of paintings; therefore, it is nowadays increasingly involved in relevant studies. In the present work, a state-of-the-art MA-XRF set-up is utilized to identify the painting materials and techniques and document the state of preservation of an early 19th-century AD Greek religious panel painting (“icon”). The artifact in consideration has received extensive restoration interventions in the past and is considerably decayed; for these reasons, the interpretation of the relevant MA-XRF elemental intensity distribution maps is challenging. In this framework, it is demonstrated how the elemental distribution maps can be explored and interpreted to lead to a thorough investigation of the painting in consideration. In particular, the MA-XRF data interpretation allowed for the identification of the original palette that includes the rather rarely employed–in icon painting-yellow lead-antimonate pigment, led to the spotting of an invisible inscription, to the documentation of the preparation/gesso layer and the preliminary drawing. Additionally, it was possible to discriminate between the original painting and the later interventions, while the collected data revealed that the painting originally had two cross-bars attached to its back. Ultimately, the presented case study can be utilized as a guide for the proper interpretation of MA-XRF data from decayed and altered icons. Full article
Show Figures

Figure 1

Back to TopTop