Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (100)

Search Parameters:
Keywords = commercial pure titanium (Cp-Ti)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 9122 KiB  
Article
Computational Mechanics of Polymeric Materials PEEK and PEKK Compared to Ti Implants for Marginal Bone Loss Around Oral Implants
by Mohammad Afazal, Saba Afreen, Vaibhav Anand and Arnab Chanda
Prosthesis 2025, 7(4), 93; https://doi.org/10.3390/prosthesis7040093 - 1 Aug 2025
Viewed by 215
Abstract
Background/Objectives: Dental practitioners widely use dental implants to treat traumatic cases. Titanium implants are currently the most popular choice among dental practitioners and surgeons. The discovery of newer polymeric materials is also influencing the interest of dental professionals in alternative options. A comparative [...] Read more.
Background/Objectives: Dental practitioners widely use dental implants to treat traumatic cases. Titanium implants are currently the most popular choice among dental practitioners and surgeons. The discovery of newer polymeric materials is also influencing the interest of dental professionals in alternative options. A comparative study between existing titanium implants and newer polymeric materials can enhance professionals’ ability to select the most suitable implant for a patient’s treatment. This study aimed to investigate material property advantages of high-performance thermoplastic biopolymers such as PEEK and PEKK, as compared to the time-tested titanium implants, and to find the most suitable and economically fit implant material. Methods: Three distinct implant material properties were assigned—PEEK, PEKK, and commercially pure titanium (CP Ti-55)—to dental implants measuring 5.5 mm by 9 mm, along with two distinct titanium (TI6AL4V) abutments. Twelve three-dimensional (3D) models of bone blocks, representing the mandibular right molar area with Osseo-integrated implants were created. The implant, abutment, and screw were assumed to be linear; elastic, isotropic, and orthotropic properties were attributed to the cancellous and cortical bone. Twelve model sets underwent a three-dimensional finite element analysis to evaluate von Mises stress and total deformation under 250 N vertical and oblique (30 degree) loads on the top surface of each abutment. Results: The study revealed that the time-tested titanium implant outperforms PEEK and PEKK in terms of marginal bone preservation, while PEEK outperforms PEKK. Conclusions: This study will assist dental practitioners in selecting implants from a variety of available materials and will aid researchers in their future research. Full article
Show Figures

Figure 1

14 pages, 3007 KiB  
Article
Bone-like Carbonated Apatite Titanium Anodization Coatings Produced in Citrus sinensis-Based Electrolytes
by Amisha Parekh, Amol V. Janorkar and Michael D. Roach
Appl. Sci. 2025, 15(15), 8548; https://doi.org/10.3390/app15158548 - 31 Jul 2025
Viewed by 193
Abstract
Enhancing osseointegration is a common goal for many titanium implant coatings, since the naturally forming oxides are often bioinert and exhibit less than ideal bone-to-implant contact. Oxide coating surface topographies, chemistries, and crystallinities are known to play key roles in enhancing bone–implant interactions. [...] Read more.
Enhancing osseointegration is a common goal for many titanium implant coatings, since the naturally forming oxides are often bioinert and exhibit less than ideal bone-to-implant contact. Oxide coating surface topographies, chemistries, and crystallinities are known to play key roles in enhancing bone–implant interactions. In the present study, two novel anodization processes were developed in electrolytes based on juiced navel oranges to create bioactive oxide coatings on commercially pure titanium (CPTi) surfaces. Both oxide groups revealed multi-scaled micro and nano surface topographies, significant Ca and P-dopant incorporation exhibiting Ca/P ratios similar to human bone (1.7 and 1.8), and physiologically relevant Mg uptake levels of <0.1% and 1.4 at%. XRD and FTIR analyses of each oxide revealed a combination of tricalcium phosphate and hydroxyapatite phases that showed carbonate substitutions indicative of bone-like apatite formation. Finally, VDI indentation testing revealed good adhesion strengths, minimal cracking, and no visible delamination for both oxides. In summary, the anodization processes in the present study were shown to produce carbonated tricalcium phosphate and apatite containing oxides with contrasting levels of Mg uptake that show much promise to improve future implant clinical outcomes. Full article
Show Figures

Figure 1

27 pages, 3299 KiB  
Article
Corrosion Stability and Biological Activity of Anodized cpTi for Dental Application
by Aleksandra S. Popović, Minja Miličić Lazić, Dijana Mitić, Lazar Rakočević, Dragana Jugović, Predrag Živković and Branimir N. Grgur
Metals 2025, 15(7), 817; https://doi.org/10.3390/met15070817 - 21 Jul 2025
Viewed by 397
Abstract
The anodic oxidation of titanium implants is a practical, cost-effective method to enhance implant success, especially due to rising hypersensitivity concerns. This study investigated the electrochemical behavior, surface characteristics, and biocompatibility of anodized commercially pure titanium (cpTi, grade IV). Anodization is performed on [...] Read more.
The anodic oxidation of titanium implants is a practical, cost-effective method to enhance implant success, especially due to rising hypersensitivity concerns. This study investigated the electrochemical behavior, surface characteristics, and biocompatibility of anodized commercially pure titanium (cpTi, grade IV). Anodization is performed on polished, cleaned cpTi sheet samples in 1 M H2SO4 using a constant voltage of 15 V for 15 and 45 min. The color of the oxide layer is evaluated using the CIELab color space, while composition is analyzed by a scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS). Additionally, X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) are performed to identify and monitor the phase transformations of the formed titanium oxides. Corrosion measurements are performed in 9 g L−1 NaCl, pH = 7.4, and show the excellent corrosion stability of the anodized samples in comparison with pure titanium. The biological response is assessed by determining mitochondrial activity and gene expression in human fibroblasts. Anodized surfaces, particularly Ti-45, promote higher mitochondrial activity and the upregulation of adhesion-related genes (N-cadherin and Vimentin) in human gingival fibroblasts, indicating improved biocompatibility and the potential for enhanced early soft tissue integration. Full article
Show Figures

Graphical abstract

11 pages, 809 KiB  
Article
Antimicrobial Behavior of Surface-Treated Commercially Pure Titanium (CpTi) for Dental Implants in Artificial Saliva—In Vitro Study
by Roshni Bopanna, Neetha J. Shetty, Ashith M. Varadaraj, Himani Kotian, Sameep Shetty and Simran Genescia
Antibiotics 2025, 14(7), 715; https://doi.org/10.3390/antibiotics14070715 - 16 Jul 2025
Viewed by 303
Abstract
Background/Objectives:Titanium implant surface modifications enhance osseointegration and prevent microbial colonization, improving implant longevity. Antimicrobial coatings, particularly cerium- and bismuth-doped hydroxyapatite (CeHAp and BiHAp), have gained attention for reducing infection-related complications. This study evaluates the antimicrobial activity of CeHAp and BiHAp coatings on [...] Read more.
Background/Objectives:Titanium implant surface modifications enhance osseointegration and prevent microbial colonization, improving implant longevity. Antimicrobial coatings, particularly cerium- and bismuth-doped hydroxyapatite (CeHAp and BiHAp), have gained attention for reducing infection-related complications. This study evaluates the antimicrobial activity of CeHAp and BiHAp coatings on CpTi compared to untreated CpTi in artificial saliva at pH levels of 4.5, 6.5, and 8. Methods: Antibacterial efficacy against Staphylococcus aureus (S. aureus), Escherichia coli (E. coli), and Candida albicans (C. albicans) was assessed using the broth dilution method. Titanium rods coated with test compounds were incubated in inoculated nutrient broth, and microbial inhibition was determined via optical density at 600 nm. A statistical analysis was performed using the Kruskal–Wallis ANOVA test, the median and Interquartile Range were determined for the variables, and a Dwass–Steel–Critchlow–Fligner intergroup pairwise comparison was conducted. Results: The results showed that both the CeHAp and BiHAp coatings demonstrated significant antimicrobial activity against S. aureus (OD = 0.01) at pH 6.5, which was more pronounced than the activity observed against E. coli (OD = 0.05), with the difference being statistically significant (p = 0.001). The least antimicrobial activity was observed against C. albicans (0.21) at pH 8 (p = 0.001). Conclusion: These findings highlight the pH-dependent effectiveness of BiHAp and CeHAp coatings in inhibiting microbial growth. Their application on titanium implants may enhance antimicrobial properties, contributing to improved dental implant success and broader biomedical applications. Full article
(This article belongs to the Section Antimicrobial Materials and Surfaces)
Show Figures

Figure 1

24 pages, 8807 KiB  
Article
Further Studies into the Growth of Small Naturally Occurring Three-Dimensional Cracks in Additively Manufactured and Conventionally Built Materials
by Shareen Chan, Daren Peng, Andrew S. M. Ang, Michael B. Nicholas, Victor K. Champagne, Aron Birt, Alex Michelson, Sean Langan, Jarrod Watts and Rhys Jones
Crystals 2025, 15(6), 544; https://doi.org/10.3390/cryst15060544 - 6 Jun 2025
Viewed by 837
Abstract
MIL-STD-1530D and the United States Air Force (USAF) Structures Bulletin EZ-SB-19-01 require an ability to predict the growth of naturally occurring three-dimensional cracks with crack depths equal to what they term an equivalent initial damage size (EIDS) of 0.254 mm. This requirement holds [...] Read more.
MIL-STD-1530D and the United States Air Force (USAF) Structures Bulletin EZ-SB-19-01 require an ability to predict the growth of naturally occurring three-dimensional cracks with crack depths equal to what they term an equivalent initial damage size (EIDS) of 0.254 mm. This requirement holds for both additively manufactured and conventionally built parts. The authors have previously presented examples of how to perform such predictions for additively manufactured (AM) Ti-6Al-4V; wire arc additively manufactured (WAAM) 18Ni 250 Maraging steel; and Boeing Space, Intelligence and Weapon Systems laser bed powder fusion (LPBF) Scalmalloy®, which is an additively manufactured Aluminium-Scandium-Mg alloy, using the Hartman-Schijve crack growth equation. In these studies, the constants used were as determined from ASTM E647 standard tests on long cracks, and the fatigue threshold term in the Hartman-Schijve equation was set to a small value (namely, 0.1 MPa √m). This paper illustrates how this approach can also be used to predict the growth of naturally occurring three-dimensional cracks in WAAM CP-Ti (commercially pure titanium) specimens built by Solvus Global as well as in WAAM-built Inconel 718. As in the prior studies mentioned above, the constants used in this analysis were taken from prior studies into the growth of long cracks in conventionally manufactured CP-Ti and in AM Inconel 718, and the fatigue threshold term in these analyses was set to 0.1 MPa √m. These studies are complemented via a prediction of the growth of naturally occurring three-dimensional cracks in conventionally built M300 steel. Full article
(This article belongs to the Section Inorganic Crystalline Materials)
Show Figures

Figure 1

10 pages, 3299 KiB  
Article
Superstrength of Nanostructured Ti Grade 4 with Grain Boundary Segregations
by Emil I. Usmanov, Michail Yu. Gutkin, Yinxing Wu, Gang Sha and Ruslan Z. Valiev
Metals 2025, 15(6), 618; https://doi.org/10.3390/met15060618 - 30 May 2025
Viewed by 431
Abstract
Severe plastic deformation and subsequent heat treatments yield nanostructured commercially pure (CP) titanium Grade 4 with average grain size of about 100 nm and exceptional strength. To elucidate the underlying strengthening mechanisms in this nanotitanium (nanoTi), this study uses atom probe tomography (APT) [...] Read more.
Severe plastic deformation and subsequent heat treatments yield nanostructured commercially pure (CP) titanium Grade 4 with average grain size of about 100 nm and exceptional strength. To elucidate the underlying strengthening mechanisms in this nanotitanium (nanoTi), this study uses atom probe tomography (APT) to analyze the atomic structure of grain boundaries and assess impurity segregation. Results reveal the formation of grain boundary segregations, primarily composed of iron (Fe) atoms, reaching concentrations up to 3.3 ± 0.2 at% in localized regions. The average width of these segregation layers is 6.13 ± 0.45 nm. The paper considers a mechanism for forming these segregations and discusses relevant theoretical models describing their contribution to the material’s enhanced strength. Full article
Show Figures

Figure 1

13 pages, 4362 KiB  
Article
The Effect of N/O Elements on the Microstructure and Mechanical Properties of Ti-N-O Alloys
by Mingqi Shi, Ruiduo Chen, Chengsong Zhang, Zhenzhao Xu, Hanke Hu, Xiaolong Zhou and Guodong Cui
Metals 2025, 15(5), 554; https://doi.org/10.3390/met15050554 - 17 May 2025
Viewed by 499
Abstract
A novel Ti-N-O composite was prepared by powder nitriding/oxynitriding combined with the spark plasma sintering (SPS) method. The effects of N/O on the microstructure and mechanical properties of the Ti-N-O alloy were systematically studied. The results showed that the addition of N/O elements [...] Read more.
A novel Ti-N-O composite was prepared by powder nitriding/oxynitriding combined with the spark plasma sintering (SPS) method. The effects of N/O on the microstructure and mechanical properties of the Ti-N-O alloy were systematically studied. The results showed that the addition of N/O elements significantly improved the mechanical properties of commercially pure titanium (cp-Ti). The hardness reached 298.8 HV0.1 while the yield strength can reach 666 MPa. And, the O element played a leading role in regulating the microstructure and morphology of the Ti-N-O alloy. With the addition of the O element, the microstructure showed an equiaxed structure, and the characterization showed that this region is an O-enriched region, and that a small amount of nano-TiO2 particles appeared in the alloy, which together led to the change in the microstructure. At the same time, more large-angle grain boundaries were generated in the Ti-N-O alloy. This study investigated a new method for the preparation of titanium materials and provides new ideas for researching medical titanium materials. Full article
Show Figures

Graphical abstract

22 pages, 15997 KiB  
Article
Simulation and Experimental Validation of Splat Profiles for Cold-Sprayed CP-Ti with Varied Powder Morphology
by Wesley Kean Wah Tai, Martin Eberle, Samuel Pinches, Shareen S. L. Chan, Rohan Chakrabarty, Max Osborne, Daren Peng, Rhys Jones and Andrew S. M. Ang
Appl. Mech. 2025, 6(2), 33; https://doi.org/10.3390/applmech6020033 - 30 Apr 2025
Viewed by 472
Abstract
The cold spray (CS) process has gained momentum as an additive manufacturing technology, due to its low processing temperatures. Computational modelling can accompany CS experiments to optimise deposition parameters, as well as predict coating properties and their final performance. A commonly used plasticity [...] Read more.
The cold spray (CS) process has gained momentum as an additive manufacturing technology, due to its low processing temperatures. Computational modelling can accompany CS experiments to optimise deposition parameters, as well as predict coating properties and their final performance. A commonly used plasticity model is the Johnson–Cook (JC) model; however, its accuracy is limited at the high strain rates typical of cold spray. This study aims to assess the robustness of predictions using a modified JC model, particularly for two material systems of commercially pure titanium (CP-Ti) and Al6061-T6, and feedstock powders of two sizes and three morphologies. CP-Ti powders of spherical and irregular morphologies were sprayed onto CP-Ti substrates using a Titomic TKF1000 cold spray system. The cross-sectional splat profiles and flattening ratios were compared against smoothed particle hydrodynamics (SPH) simulations. The deposition process of particles was simulated using a modified JC model, implemented as an ABAQUS (2020) VUHARD user subroutine programme. The results showed that SPH simulations predicted the depth of impact, the splat profiles and the flattening ratios. Additionally, the simulations indicated that the impacting particle temperature remained below the melting point of CP-Ti throughout the process. Lastly, it was demonstrated that the irregular CP-Ti feedstock showed greater tendency of restitution than spherical feedstock. Full article
Show Figures

Figure 1

14 pages, 8230 KiB  
Article
Refinement Mechanism of Ultrafine-Grained CP-Ti Fabricated via Equal-Channel Angular Pressing
by Yanxia Gu, Jinghua Jiang, Aibin Ma and Haoran Wu
Metals 2025, 15(2), 201; https://doi.org/10.3390/met15020201 - 14 Feb 2025
Viewed by 731
Abstract
Grains of commercially pure titanium (CP-Ti) can be refined via rotary-die equal-channel angular pressing (RD-ECAP) to meet higher application requirements. However, the grain refinement mechanism of CP-Ti during RD-ECAP has not been fully studied. Herein, CP-Ti was processed up to four passes by [...] Read more.
Grains of commercially pure titanium (CP-Ti) can be refined via rotary-die equal-channel angular pressing (RD-ECAP) to meet higher application requirements. However, the grain refinement mechanism of CP-Ti during RD-ECAP has not been fully studied. Herein, CP-Ti was processed up to four passes by RD-ECAP to obtain an ultrafine-grained structure. The microstructure evolution, refinement mechanism, and dynamic recrystallization (DRX) behavior was investigated by TEM and EBSD analysis. The results revealed that after two passes, banded structures with numerous LAGBs inside were detected, while after four passes, most grains were equiaxed with HAGBs and the average grain size was about 0.5 μm. The fraction of HAGBs reached 78.6% for the four-pass sample, which was higher than that of two-pass sample. The fraction of deformed grains declined and the proportion of recrystallized grains increased as the pass number increased from two to four. The misorientation gradient analysis showed that subgrains with LAGBs evolved into new grains with HAGBs gradually to generate ultrafine grains. The refinement mechanism of CP-Ti during RD-ECAP can be concluded as continuous DRX (CDRX). In addition, the relationship between DRX type and the processing conditions as well as stacking fault energies (SFEs) of metals was innovatively explored, providing a new approach for predicting microstructure. Full article
Show Figures

Figure 1

15 pages, 3199 KiB  
Article
Scratch-Induced Deformation Behavior of Wire-Arc Directed Energy Deposited α-Titanium
by Blanca Palacios, Sohail M. A. K. Mohammed, Tanaji Paul, Gia Garino, Carlos Maribona, Sean Langan and Arvind Agarwal
Materials 2025, 18(3), 724; https://doi.org/10.3390/ma18030724 - 6 Feb 2025
Cited by 1 | Viewed by 1014
Abstract
This study investigates the scratch response of α-phase commercially pure titanium (cp-Ti) produced via wire arc directed energy deposition (WDED), focusing on the thermal history and directional effects. Progressive scratch tests (1–50 N) revealed heterogeneous wear properties between the top and bottom layers, [...] Read more.
This study investigates the scratch response of α-phase commercially pure titanium (cp-Ti) produced via wire arc directed energy deposition (WDED), focusing on the thermal history and directional effects. Progressive scratch tests (1–50 N) revealed heterogeneous wear properties between the top and bottom layers, with the top layer exhibiting higher material recovery (58 ± 5%) and wear volume (5.02 × 10−3 mm3) compared to the bottom layer (42 ± 5% recovery, 4.46 × 10−3 mm3), attributed to slower cooling rates and coarser grains enhancing ductility. The variation in the properties stems from the thermal gradient generated during WDED. Electron backscatter diffraction analysis showed higher kernel average misorientation (KAM) in the bottom layer (0.84° ± 0.49° vs. 0.51° ± 0.44°), affecting plasticity by reducing dislocation and twin boundary mobility. No significant differences were observed between longitudinal and transverse orientations, with coefficients of friction averaging 0.80 ± 0.12 and 0.79 ± 0.13, respectively. Abrasive wear dominated as the primary mechanism, accompanied by subsurface plastic deformation. These findings highlight the significant influence of WDED thermal history in governing scratch resistance and deformation behavior, providing valuable insights for optimizing cp-Ti components for high-performance applications. Full article
Show Figures

Figure 1

17 pages, 16276 KiB  
Article
Effect of Counterbody Material on the Boundary Lubrication Behavior of Commercially Pure Titanium in a Motor Oil
by Yizhao Liu, Mohammed Al-Shan, Richard Bailey and Yong Sun
Lubricants 2024, 12(12), 439; https://doi.org/10.3390/lubricants12120439 - 10 Dec 2024
Cited by 1 | Viewed by 1313
Abstract
Titanium possesses many useful properties and is a technologically important material in engineering. However, lubrication of titanium has long been a problem that has prevented titanium from being more widely used. This is due to its poor tribological properties, deriving from its high [...] Read more.
Titanium possesses many useful properties and is a technologically important material in engineering. However, lubrication of titanium has long been a problem that has prevented titanium from being more widely used. This is due to its poor tribological properties, deriving from its high tendency towards adhesive wear, material transfer, and abrasive wear. Lubrication is a system engineering which involves material combinations, material surfaces, lubricants, and operating conditions as a system. In this work, the boundary lubrication behavior of commercially pure titanium (CP-Ti) sliding against various counterbody materials in a motor oil (0W-30) was investigated under ball-on-plate reciprocating sliding conditions. The counterbody materials (balls) include CP-Ti, ceramic (Al2O3), steel (AISI 52100), and polymer (nylon). The results show that depending on material combination, the lubricating behavior can be divided into three categories, i.e., (1) lubrication failure (Ti-Ti), (2) improved lubrication but with friction instability (Ti-Al2O3), and (3) effective lubrication (Ti–steel and Ti–nylon). Lubrication failure of the Ti-Ti pair leads to high and unstable friction and severe wear from both the plate and ball, while friction instability of the Ti-Al2O3 pair leads to friction spikes and high wear rates. Effective lubrication of the Ti–steel pair results in low and smooth friction and much-reduced wear rates of the Ti plate by nearly 10,000 times. However, there is a load-dependence of the lubrication effectiveness of the Ti–steel pair. Although the Ti–nylon pair is effectively lubricated in terms of much-reduced friction, the nylon ball suffers from severe wear. The friction and wear mechanisms of the various sliding pairs are discussed in this paper. Full article
Show Figures

Figure 1

25 pages, 8713 KiB  
Article
The Effect of Specimen Width on the Deformation Behavior and Formability of cp-Ti Grade 4 Sheets During Uniaxial and Cyclic Bending Under Tension Loading
by Desmond Mensah, Nicholas Pitkin, Michael P. Miles, David T. Fullwood, Marko Knezevic and Brad Kinsey
Materials 2024, 17(23), 5756; https://doi.org/10.3390/ma17235756 - 25 Nov 2024
Viewed by 1046
Abstract
This study examines the specimen size-dependent deformation behavior of commercially pure titanium grade 4 (cp-Ti grade 4) sheets under tension, with strain paths between uniaxial tension (UT) and plane-strain tension and compares the results with cyclic bending under tension (CBT) data. Specimens of [...] Read more.
This study examines the specimen size-dependent deformation behavior of commercially pure titanium grade 4 (cp-Ti grade 4) sheets under tension, with strain paths between uniaxial tension (UT) and plane-strain tension and compares the results with cyclic bending under tension (CBT) data. Specimens of varying widths (11.7, 20, 60, 100, and 140 mm) were tested in both rolling (RD) and transverse (TD) directions. The research employed digital image correlation for full-field strain measurements, finite element simulations, and fracture surface thickness data. Contrary to traditional forming concepts, i.e., the forming limit diagram (FLD) has the lowest major strain at the plane-strain condition, and the fracture forming limit has decreased major strain with increasing (less negative) minor strain, wider specimens exhibited higher major strains at strain localization and fracture under UT. In contrast, CBT findings showed decreased formability with increasing width, i.e., closer to plane-strain deformation, as expected. Strain distribution analyses revealed a transition from nearly uniform deformation in narrow specimens to multiaxial strain states in wider specimens. Thickness measurements along the fracture surface revealed a steeper profile in UT compared to CBT, indicating more localized deformation and necking in UT. In comparison with AA6016-T4, the cp-Ti grade 4 showed greater thickness, suggesting lower susceptibility to localized thinning. Strong anisotropy was observed between the RD and TD, with TD specimens showing higher formability and steeper thickness gradients in UT. Strain fields, along with thickness reduction and adiabatic heating, are used to rationalize the observed width-sensitive deformation behavior of cp-Ti sheets. Notably, CBT improved overall formability compared to UT due to its ability to distribute strain more evenly and delay critical necking. The contrasting trends between simple UT and CBT emphasize the relationship between loading conditions, specimen geometry, and material behavior in determining formability. These findings highlight the ability of the CBT test to create known and desired deformation effects, i.e., lower major strain at failure with increasing specimen width, and more uniform deformation, i.e., consistent thinning across the specimen width, for cp-Ti. Given the observed effects of width in UT, the selection of the testing method is critical for cp-Ti to ensure that results reflect expected material behavior. Full article
Show Figures

Figure 1

19 pages, 11979 KiB  
Article
Residual Stress Homogenization of Hybrid Implants
by Marta Sanjuán Álvarez, Daniel Robles, Javier Gil Mur, Saray Fernández-Hernández, Esteban Pérez-Pevida and Aritza Brizuela-Velasco
Bioengineering 2024, 11(11), 1149; https://doi.org/10.3390/bioengineering11111149 - 15 Nov 2024
Viewed by 1042
Abstract
Objectives: Hybrid implants commonly exhibit decreased corrosion resistance and fatigue due to differences in compressive residual stresses between the smooth and rough surfaces. The main objective of this study was to investigate the influence of an annealing heat treatment to reduce the residual [...] Read more.
Objectives: Hybrid implants commonly exhibit decreased corrosion resistance and fatigue due to differences in compressive residual stresses between the smooth and rough surfaces. The main objective of this study was to investigate the influence of an annealing heat treatment to reduce the residual stresses in hybrid implants. Methodology: Commercially pure titanium (CpTi) bars were heat-treated at 800 °C and different annealing times. Optical microscopy was used to analyze the resulting grain growth kinetics. Diffractometry was used to measure residual stress after heat treatment, corrosion resistance by open circuit potential (EOCP), corrosion potentials (ECORR), and corrosion currents (ICORR) of heat-treated samples, as well as fatigue behavior by creep testing. The von Mises distribution and the resulting microstrains in heat-treated hybrid implants and in cortical and trabecular bone were assessed by finite element analysis. The results of treated hybrid implants were compared to those of untreated hybrid implants and hybrid implants with a rough surface (shot-blasted). Results: The proposed heat treatment (800 °C for 30 min, followed by quenching in water at 20 °C) could successfully homogenize the residual stress difference between the two surfaces of the hybrid implant (−20.2 MPa). It provides better fatigue behavior and corrosion resistance (p ˂ 0.05, ANOVA). Stress distribution was significantly improved in the trabecular bone. Heat-treated hybrid implants performed worse than implants with a rough surface. Clinical significance: Annealing heat treatment can be used to improve the mechanical properties and corrosion resistance of hybrid surface implants by homogenizing residual stresses. Full article
(This article belongs to the Special Issue Application of Bioengineering to Dentistry)
Show Figures

Graphical abstract

13 pages, 14597 KiB  
Article
An Experimental and Simulation Study on the Formability of Commercial Pure Titanium Foil
by Jenn-Terng Gau, Kechuang Zhang and Jiaqi Zhu
Micromachines 2024, 15(9), 1096; https://doi.org/10.3390/mi15091096 - 29 Aug 2024
Viewed by 925
Abstract
In order to understand the formability of as-received tempered commercial pure titanium grade 2 foils (CP Ti Gr2) with a thickness of 38 µm, a series of micro limited dome height (µ-LDH) tests were conducted in quasi-static speed (0.01 mm/s) at room temperature [...] Read more.
In order to understand the formability of as-received tempered commercial pure titanium grade 2 foils (CP Ti Gr2) with a thickness of 38 µm, a series of micro limited dome height (µ-LDH) tests were conducted in quasi-static speed (0.01 mm/s) at room temperature without the use of a lubricant. A technique developed at NIU was also used to create micro-circular grids (ϕ50 μm) on the as-received material. The forming limit curve (FLC) of the CP Ti Gr2 foils was obtained through the proposed µ-LDH test. For having mechanical properties of the CP Ti Gr2 foils for LS-Dyna FEA (Finite Element Analysis) simulations, a series of tensile tests in three directions were also conducted at room temperature with the same speed. The obtained FLC has been validated using a micro deep drawing case study in which both FEA simulations and experiments were conducted and compared. It has been proven in this study that the FLC obtained using the proposed µ-LDH test can be used for an extremely thin sheet-metal-forming process by the automotive, aerospace, medical, energy, and electronic industries, etc., right away for product design, forming process development, tool and die designs, and simulations, etc. Full article
(This article belongs to the Special Issue Ultra-Precision Manufacturing)
Show Figures

Figure 1

13 pages, 4503 KiB  
Article
Bovine Mineral Grafting Affects the Hydrophilicity of Dental Implant Surfaces: An In Vitro Study
by Allyson Newman, Nina K. Anderson and Georgios E. Romanos
Materials 2024, 17(16), 4052; https://doi.org/10.3390/ma17164052 - 15 Aug 2024
Cited by 1 | Viewed by 1415
Abstract
Wettability is recognized as an important property of implant surfaces for ensuring improved biological responses. However, limited information exists on how bone grafting procedures including materials influence the hydrophilic behavior of implant surfaces. This in vitro study aimed to investigate the influence of [...] Read more.
Wettability is recognized as an important property of implant surfaces for ensuring improved biological responses. However, limited information exists on how bone grafting procedures including materials influence the hydrophilic behavior of implant surfaces. This in vitro study aimed to investigate the influence of two bovine grafting materials after hydration on the wettability of four different disk surfaces: commercially pure titanium (CP-Ti), titanium–zirconium dioxide (TiZrO2-Cerid®), zirconia (SDS®), and niobium. Wettability tests were performed on each of the four implant surfaces with a solution of 0.9% sodium chloride after mixture with W-boneTM (Group A) or Bio-Oss® (Group B) or 0.9% sodium chloride alone (Group C). In total, 360 contact angle measurements were completed with n = 30 per group. Statistical analysis was performed using a one-way analysis with variance (ANOVA) test with a significant mean difference at the 0.05 level. For pure titanium, Group A demonstrated increased hydrophilicity compared to Group B. Both TiZrO2 and zirconia showed significant differences for Groups A, B and C, exhibiting a decrease in hydrophilicity after the use of bovine grafting materials compared to titanium surfaces. Niobium remained consistently hydrophobic. In summary, this study revealed that bovine grafting materials may diminish the hydrophilicity of zirconia surfaces and exert varied effects on titanium and niobium. These findings contribute to the understanding of implant surface interactions with grafting materials, offering insights for optimizing biological responses in implantology. Full article
(This article belongs to the Special Issue Advanced Dental Materials for Periodontal and Bone Regeneration)
Show Figures

Figure 1

Back to TopTop