Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = biomimic membrane

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2661 KB  
Article
The Effect of Nanobubbles on Transdermal Applications
by Athanasios Ch. Mitropoulos, Christina Pappa, Ramonna I. Kosheleva and George Z. Kyzas
Nanomaterials 2023, 13(18), 2600; https://doi.org/10.3390/nano13182600 - 20 Sep 2023
Cited by 5 | Viewed by 3381
Abstract
In the present work, a new method for dermal delivery using nanobubbles (NBs) is investigated. Oxygen NBs are generated in deionized water and used to produce cosmetic formulations with hyaluronic acid as an active ingredient. Nanobubbles result in the improvement of the effect [...] Read more.
In the present work, a new method for dermal delivery using nanobubbles (NBs) is investigated. Oxygen NBs are generated in deionized water and used to produce cosmetic formulations with hyaluronic acid as an active ingredient. Nanobubbles result in the improvement of the effect and penetration of the active ingredient through Strat-M, a synthetic membrane that resembles human skin. Experiments conducted with the Franz Cell device confirm the greater penetration of the active ingredient into Strat-M due to NBs, compared to cosmetic formulations that do not contain NBs. The effect of NBs was further examined by measuring UV-Vis and FTIR spectra. A possible mechanism was outlined, too. It was also found that NBs do not change the pH or the FTIR spectrum of the cosmetic serum indicating non-toxicity. Full article
Show Figures

Figure 1

14 pages, 4835 KB  
Article
Bruch’s-Mimetic Nanofibrous Membranes Functionalized with the Integrin-Binding Peptides as a Promising Approach for Human Retinal Pigment Epithelium Cell Transplantation
by Shaocheng Wang, Siyong Lin, Bo Xue, Chenyu Wang, Nana Yan, Yueyan Guan, Yuntao Hu and Xuejun Wen
Molecules 2022, 27(4), 1429; https://doi.org/10.3390/molecules27041429 - 21 Feb 2022
Cited by 11 | Viewed by 3677
Abstract
Background: This study aimed to develop an ultrathin nanofibrous membrane able to, firstly, mimic the natural fibrous architecture of human Bruch’s membrane (BM) and, secondly, promote survival of retinal pigment epithelial (RPE) cells after surface functionalization of fibrous membranes. Methods: Integrin-binding peptides (IBPs) [...] Read more.
Background: This study aimed to develop an ultrathin nanofibrous membrane able to, firstly, mimic the natural fibrous architecture of human Bruch’s membrane (BM) and, secondly, promote survival of retinal pigment epithelial (RPE) cells after surface functionalization of fibrous membranes. Methods: Integrin-binding peptides (IBPs) that specifically interact with appropriate adhesion receptors on RPEs were immobilized on Bruch’s-mimetic membranes to promote coverage of RPEs. Surface morphologies, Fourier-transform infrared spectroscopy spectra, contact angle analysis, Alamar Blue assay, live/dead assay, immunofluorescence staining, and scanning electron microscopy were used to evaluate the outcome. Results: Results showed that coated membranes maintained the original morphology of nanofibers. After coating with IBPs, the water contact angle of the membrane surfaces varied from 92.38 ± 0.67 degrees to 20.16 ± 0.81 degrees. RPE cells seeded on IBP-coated membranes showed the highest viability at all time points (Day 1, p < 0.05; Day 3, p < 0.01; Days 7 and 14, p < 0.001). The proliferation rate of RPE cells on uncoated poly(ε-caprolactone) (PCL) membranes was significantly lower than that of IBP-coated membranes (p < 0.001). SEM images showed a well-organized hexa/polygonal monolayer of RPE cells on IBP-coated membranes. RPE cells proliferated rapidly, contacted, and became confluent. RPE cells formed a tight adhesion with nanofibers under high-magnification SEM. Our findings confirmed that the IBP-coated PCL membrane improved the attachment, proliferation, and viability of RPE cells. In addition, in this study, we used serum-free culture for RPE cells and short IBPs without immunogenicity to prevent graft rejection and immunogenicity during transplantation. Conclusions: These results indicated that the biomimic BM-IBP-RPE nanofibrous graft might be a new, practicable approach to increase the success rate of RPE cell transplantation. Full article
(This article belongs to the Special Issue Advances in Research of Short Peptides)
Show Figures

Figure 1

13 pages, 2801 KB  
Article
Solid-Contact Potentiometric Sensors Based on Main-Tailored Bio-Mimics for Trace Detection of Harmine Hallucinogen in Urine Specimens
by Abde El-Galil E. Amr, Ayman H. Kamel, Abdulrahman A. Almehizia, Ahmed Y. A. Sayed and Hisham S. M. Abd-Rabboh
Molecules 2021, 26(2), 324; https://doi.org/10.3390/molecules26020324 - 10 Jan 2021
Cited by 8 | Viewed by 3534
Abstract
All-solid-state potentiometric sensors have attracted great attention over other types of potentiometric sensors due to their outstanding properties such as enhanced portability, simplicity of handling, affordability and flexibility. Herein, a novel solid-contact ion-selective electrode (SC-ISE) based on poly(3,4-ethylenedioxythiophene) (PEDOT) as the ion-to-electron transducer [...] Read more.
All-solid-state potentiometric sensors have attracted great attention over other types of potentiometric sensors due to their outstanding properties such as enhanced portability, simplicity of handling, affordability and flexibility. Herein, a novel solid-contact ion-selective electrode (SC-ISE) based on poly(3,4-ethylenedioxythiophene) (PEDOT) as the ion-to-electron transducer was designed and characterized for rapid detection of harmine. The harmine-sensing membrane was based on the use of synthesized imprinted bio-mimics as a selective material for this recognition. The imprinted receptors were synthesized using acrylamide (AA) and ethylene glycol dimethacrylate (EGDMA) as functional monomer and cross-linker, respectively. The polymerization process was carried out at 70 °C in the presence of dibenzoyl peroxide (DBO) as an initiator. The sensing membrane in addition to the solid-contact layer was applied to a glassy-carbon disc as an electronic conductor. All performance characteristics of the presented electrode in terms of linearity, detection limit, pH range, response time and selectivity were evaluated. The sensor revealed a wide linearity over the range 2.0 × 10−7–1.0 × 10−2 M, with a detection limit of 0.02 µg/mL and a sensitivity slope of 59.2 ± 0.8 mV/hamine concentration decade. A 40 mM Britton–Robinson (BR) buffer solution at pH of 6 was used for all harmine measurements. The electrode showed good selectivity towards harmine over other common interfering ions, and maintained a stable electrochemical response over two weeks. After applying the validation requirements, the proposed method revealed good performance characteristics. Method precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty were also evaluated. These analytical capabilities support the fast and direct assessment of harmine in different urine specimens. The analytical results were compared with the standard liquid chromatographic method. The results obtained demonstrated that PEDOT/PSS was a promising solid-contact ion-to-electron transducer material in the development of harmine-ISE. The electrodes manifested enhanced stability and low cost, which provides a wide number of potential applications for pharmaceutical and forensic analysis. Full article
Show Figures

Graphical abstract

10 pages, 3425 KB  
Article
Liquid Contact-Selective Potentiometric Sensor Based on Imprinted Polymeric Beads Towards 17β-Estradiol Determination
by Ayman H. Kamel, Abd El-Galil E. Amr, Hoda R. Galal, Elsayed A. Elsayed and Ahmed I. Al-Sayady
Polymers 2020, 12(7), 1506; https://doi.org/10.3390/polym12071506 - 7 Jul 2020
Cited by 8 | Viewed by 3295
Abstract
Novel potentiometric devices “ion-selective electrodes (ISEs)” were designed and characterized for the detection of 17β-estradiol (EST) hormone. The selective membranes were based on the use of man-tailored biomimics (i.e., molecularly imprinted polymers (MIPs)) as recognition ionophores. The synthesized MIPs include a functional monomer [...] Read more.
Novel potentiometric devices “ion-selective electrodes (ISEs)” were designed and characterized for the detection of 17β-estradiol (EST) hormone. The selective membranes were based on the use of man-tailored biomimics (i.e., molecularly imprinted polymers (MIPs)) as recognition ionophores. The synthesized MIPs include a functional monomer (methacrylic acid (MAA)) and a cross-linker (ethylene glycol dimethacrylic acid (EGDMA)) in their preparation. Changes in the membrane potential induced by the dissociated 17β-estradiol were investigated in 50 mM CO32−/HCO3 buffer solution at pH 10.5. The ion-selective electrodes (ISEs) exhibited fast response and good sensitivity towards 17β-estradiol with a limit of detection 1.5 µM over a linear range starts from 2.5 µM with an anionic response of 61.2 ± 1.2 mV/decade. The selectivity pattern of the proposed ISEs was also evaluated and revealed an enhanced selectivity towards EST over several phenolic compounds. Advantages revealed by the presented sensor (i.e., wide range of assay, enhanced accuracy and precision, low limit of detection, good selectivity, long-term potential stability, rapid response and long life-span and absence of any sample pretreatment steps) suggest its use in routine quality control/quality assurance tests. They were successfully applied to estradiol determination in biological fluids and in different pharmaceutical preparations collected from the local market. Full article
(This article belongs to the Special Issue Advanced Polymeric Materials)
Show Figures

Figure 1

Back to TopTop